Home
Intel E40GQSFPSR
Contents
1. Configuration No of Ports Single Pack Bulk 5 Pack Intel Ethernet Converged Network Adapter X520 QDA1 X520QDA1 Intel Ethernet Converged Network Adapter XL710 QDA1 XL710QDA1 XL710QDA1BLK Intel Ethernet Converged Network Adapter XL710 QDA2 XL710QDA2 XL710QDA2BLK Optical Characteristics Top 0 C to 70 C VCC 3 15 to 3 45 V Parameter Symbol Min Typ Max Unit Note Transmitter per Lane Signaling Speed per Lane 10 5 Gb s 1 Center Wavelength 840 860 nm RMS Spectral Width SW 0 65 nm Average Launch Power per Lane TXP 7 6 1 0 dBm Transmit OMA per Lane TxOMA 5 6 3 0 dBm 2 Difference in Power between any two lanes OMA DP 4 0 dB Peek Power per Lane PP 4 0 dBm Launch Power OMA minus TDP per Lane P TDP 6 5 dBm TDP per Lane TDP 3 5 dBm Optical Extinction Ratio ER 3 0 dB Optical Return Loss Tolerance ORL 12 dB gt 86 at 19 um Encircled Flux FLX lt 30 at 4 5 um dBm Average launch power of OFF transmitter per lane 30 dBm Reletive Intensity Noise RIN 128 dB Hz Transmitter eye mask definition Od X2 X3 Dea Y1 Y2 Y3 0 27 0 35 0 4 Receiver per Lane Signaling Speed per Lane 10 5 GBd 3 Center Wavelength 840 860 nm Damage Threshold DT 3 4 dBm Average Receive Power per Lane RXP 9 5 2 4 dBm Receive Power OMA per Lane RxOMA 3 0 dBm Stressed Reveiver Sensitivity OMA per Lane SRS dBm Peak Power per Lane PP dBm Receiver Reflectance Conditions of stressed receiver sensitivity test Vertical Eye
2. Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them The information here is subject to change without notice Do not finalize a design with this information The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications Current characterized errata are available on request Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order Copies of documents which have an order number and are referenced in this document or other Intel literature may be obtained by calling 1 800 548 4725 or go to http www intel com design literature htm Copyright 2014 Intel Corporation All rights reserved Intel the Intel logo Net ffect and Xeon are trademarks of Intel Corporation in the U S and other countries Other names and brands may be claimed as the property of others intel Printed in USA LH TAR U DM Please Recycle amp 330381 001US
3. Closure Penalty VECP per lane 1 9 Stressed eye J2 jitter per lane 0 3 Stressed eye J9 jitter per lane 0 47 OMA of each aggressor lane 0 4 Rx jitter tolerance in OMA per lane 5 4 Conditions of receiver jitter tolerance test Jitter frequency and peak to peak amplitude Jitter frequency and peak to peak amplitude OMA of each aggressor lane 75 5 357 1 0 4 Loss of Optic Signal LOS De Assert 12 Loss of Optic Signal LOS Assert Loss of Optic Signal LOS Hysteresis Notes 1 Transmitter consists or four lasers operating at a maximum rate of 10 5 Gb s each 2 Even if TDP is lt 0 9 dB the OMA min must exceed this value 3 Receiver consists of four photodetectors operating at a maximum rate of 10 5 Gb s each 2 Electrical Characteristics Top 0 C to 70 C VCC 3 15 to 3 45 V Power mW Volt mV 0 787 125 935 971 1055 Pre Emphasis into 100 Ohms mV 175 971 1007 1103 325 1075 1111 1190 Figure 1 Power Dissipation mW maximum vs Rx Output Conditions Parameter Symbol Min Typ Max Unit Note Vcc1 Supply Voltage VccTx 3 15 3 45 V VccRx Supply Current Icc 350 mA Link Turn On Time Transmit turn on time 2000 ms 2 Transmitter per Lane Single ended input voltage tolerance VinT 0 3 4 0 V Differnential data input swing
4. Vin pp 180 1200 mVpp 3 Differnential input threshold 50 mV AC common mode input voltage tolerance RMS 15 mV Differential imput return loss Per IEEE P802 3ba Section 86A 4 1 1 dB 4 J2 Jitter Tolerance Jt2 0 17 UI J9 Jitter Tolerance Jt9 0 29 UI Data Dependent Pulse Width Shrinkage DDPWS 0 07 UI X1 X2 0 11 0 31 UI Eye mask coordinates 5 y i Y1 Y2 95 350 mV Receiver per Lane Single ended output voltage 0 3 4 0 V Differnential data output swing Vout pp 0 800 mVpp 7 8 AC common mode output voltage RMS 75 mV Termination mismatch at 1 MHz 5 Differnetial output return loss Per IEEE P802 3ba Section 86A 4 2 1 dB Common mode output return loss Per IEEE P802 3ba Section 86A 4 2 2 dB 4 Output transition time 20 to 80 28 ps J2 Jitter output Jo2 0 42 Ul J9 Jitter output Jo9 0 65 UI X1 X2 0 29 0 5 Ul Eye mask coordinates 1 6 y i Y1 Y2 150 425 mV X1 X2 0 29 0 5 UI Eye mask coordinates 2 5 2 Y1 Y2 125 500 mV Power Supply Ripple Tolerance PSR 50 mVpp Notes 1 Maximum total power value is specified across the full temperature and voltage range 2 From power on and end of any fault conditions 3 After internal AC coupling Self biasing 100 Q differential input 4 10 MHz to 11 1 GHz range 5 Hit ratio 5 x 10 5 Valid for all settings in Figure 1 6 Hit ratio 5 x 10 5 Valid only for the shaded setting in Figure 1 7 AC coupled with 100 Q differential output impedence 8 Settable in four diecrete s
5. IMPLIED BY ESTOPPEL OR OTHERWISE TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT EXCEPT AS PROVIDED IN INTEL S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO SALE AND OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT A Mission Critical Application is any application in which failure of the Intel Product could result directly or indirectly in personal injury or death SHOULD YOU PURCHASE OR USE INTEL S PRODUCTS FOR ANY SUCH MISSION CRITICAL APPLICATION YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES SUBCONTRACTORS AND AFFILIATES AND THE DIRECTORS OFFICERS AND EMPLOYEES OF EACH HARMLESS AGAINST ALL CLAIMS COSTS DAMAGES AND EXPENSES AND REASONABLE ATTORNEYS FEES ARISING OUT OF DIRECTLY OR INDIRECTLY ANY CLAIM OF PRODUCT LIABILITY PERSONAL INJURY OR DEATH ARISING IN ANY WAY OUT OF SUCH MISSION CRITICAL APPLICATION WHETHER OR NOT INTEL OR ITS SUBCONTRACTOR WAS NEGLIGENT IN THE DESIGN MANUFACTURE OR WARNING OF THE INTEL PRODUCT OR ANY OF ITS PARTS Intel may make changes to specifications and product descriptions at any time without notice Designers must not rely on the absence or characteristics of any features or instructions marked reserved or undefined
6. PRODUCT BRIEF Intel Ethernet QSFP Optics Network Connectivity Intel Ethernet QSFP Optics QSFP 40GBASE SR4 Optics for Intel Ethernet Converged Network Adapters Overview The Intel Ethernet 4OGBASE SR4 QSFP Optics are available for customers who would like to deploy Intel Ethernet Con verged Network Adapters with a QSFP SR optic Intel Ethernet Converged Net work Adapters with QSFP connectivity Key Features Support for 40GBASE Ethernet Hot swappable 40 Gb I O transceiver that plugs into a QSFP port Supports the 4x10 GbE mode to connect to four 1OGBASE SR optical interfaces Four channel full duplex transceiver module Single 1x12 MPO receptacle deliver proven reliable solutions for deployments of high density Ethernet for unified 1OGbE and 40GbE network connections Customers can move ef ficiently to 40GbE for high bandwidth application requirements such as content distribution high end virtualization using multiple CPUs network appliances and Applications Delivery Controllers ACD used for content caching load balancing Maximum power dissipation lt 1 5 W RoHS 6 compliant lead free Commercial temperature range 0 70 C Maximum link length 100m on OM3 MMF and 150m OM4 MMF 1 06 Gb s to 10 5 Gb s per channel multi rate capability Compatible with Intel Ethernet Converged Network Adapters and compression To ensure maximum flexibility Intel supports
7. teps via the I C interface See Figure 1 for Vout setting Regulatory Compliance Customer Support For Product Information Transceivers are Class 1 Laser Products and Intel Customer Support Services offers To speak to a customer service represen comply with US FDA regulations These a broad selection of programs including tative regarding Intel products please call products are certified to meet the Class 1 phone support and warranty service For 1 800 538 3373 U S and Canada or visit eye safety requirements of EN IEC 60825 more information contact us at www intel com support feedback htm for and the electrical safety requirements www intel com support the telephone number in your area For of EN IEC 60950 Copies of certificates are available from Intel Corporation upon request additional product information on Intel Ethernet products visit www intel com go ethernet Service and availability may vary by country By using this document in addition to any agreements you have with Intel you accept the terms set forth below You may not use or facilitate the use of this document in connection with any infringement or other legal analysis concerning Intel products described herein You agree to grant Intel a non exclusive royalty free license to any patent claim thereafter drafted which includes subject matter disclosed herein INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS NO LICENSE EXPRESS OR
8. the ability to use any combination of Intel Ethernet QSFP Optic Intel Ethernet QSFP Twinaxial Cable or Intel Ethernet QSFP Breakout Cable This enables customers to create the configuration that best meets the needs of their data center environment while ensuring compatibility between adapter and accessories General Specificatons Module Form Factor QSFP Network Standards Physical Layer Interface 40GBASE SR4 4x10GbE and 1x40GbE QSFP Module Specifications INF 8438i Specification for QSFP Quad Small Form factor Pluggable Transceiver SFF 8436 Specification for QSFP Copper and Optical Transceiver IEEE 802 3ba PMD Type 40GBASE SR4 Number of Lanes 4 Tx and 4 Rx Product Code E40GQSFPSR Compatible Intel Ethernet Converged Network Adapters Intel Ethernet Converged Network Adapter X520 QDA1 Intel Ethernet Converged Network Adapter XL710 QDA1 Intel Ethernet Converged Network Adapter XL710 QDA2 NOTE Other brands of QSFP SR optical modules will not work with the Intel Ethernet Converged Network Adapters NOTE When two Intel Ethernet Converged Network Adapter X520 and XL 710 Series QSFP devices are connected back to back they should be configured with the same Speed Duplex setting Results may vary if speed settings are mixed Compatible Intel Ethernet Converged Network Adapter Product Codes
Download Pdf Manuals
Related Search
Related Contents
Panasonic PT-L390U User's Manual cargo: professor de educação básica ii - matemática Samsung S24B750H Наръчник за потребителя Cataleg Karimix Terneros Arranque 4,5%.indd Manuale del proprietario Téléchargement EGA-500 SERIES SERVICE MANUAL Manuel d`utilisation et d`entretien pour les outils ebode IR Link Pro Mini Copyright © All rights reserved.
Failed to retrieve file