1. SPECIFICATION Maximum number of devices including softphones and Contact Center agents Maximum number of IP phones Maximum number of SIP devices users Maximum ACD Agents Maximum 5550 IP consoles Maximum number of analog phones Shipped with Main Software Storage Media Installed RAM Available MMC Slots MMC Slots for Maximum embedded T1 E1 digital trunk modules Maximum embedded BRI modules Ge MITEL 3300 CX II 3300 CXI Il 150 150 150 2 x ADI 21363 DSP modules Power Supply Quad CIM Single T1 E1 Quad BRI and DSP II 2 Does not support Dual trunk modules 2 Does not support Dual trunk modules Mitel MiVoice Business formerly Mitel Communications Director deployed on Mitel 3300 Controller provides businesses with a feature rich IP communication solution with embedded advanced user applications and ample connections to address the business s connections and device needs 3300 MXe Ill 3300 MXe Ill STANDARD EXPANDED 3300 AX 350 1 500 400 300 1 400 125 300 1 000 100 50 1 Quad DSP Module Power Supply 64 Echo 1 Quad DSP Module Power Supply 128 Echo Cancellers AMB 1 Quad DSP Module Power Supply 40 Echo Cancellers 32 GB Solid State Drive or 32 GB Solid State Drive or 2 GB Flash Drive 4 GB 160GB SATA Hard Drive 160 GB SATA Hard Drive Flash Drive for Voice Mail 512 MB 512 MB 512 MB Dual FIM Quad CIM Single and Dual T1 E1 Dual FIM Quad CIM Si
2. SPECIFICATION 3300 CONTROLLER UNIT ASU UNIT NSU STREAMLINE Temperature 40 to 122 F 40 to 122 F 40 to 122 F 10 C to 50 C 4 to 50 C 4 to 50 C 4 to 50 C Humidity 5 to 95 5 to 95 5 to 95 10 to 95 relative humidity relative humidity relative humidity relative humidity non condensing non condensing non condensing non condensing CX Il CXi II 170 BTUs ASU 170 BTUs per 60 BTUs per hour 24 Port 61 BTUs per per hour MXe Ill 750 hour ASU II 260 BTUs hour 48 Port 81 BTUs BTUs per hour AX per hour per hour 1024 BTUs per hour Air Flow A6 cubic ft min at maximum output of fans AX 110 cubic ft Acoustic Emissions Max 50dBA continuous 75dBA intermittent lt 10 duty cycle Conversion factors One watt is equal to 3 412 BTUs per hour One ton of refrigeration is equal to 12 000 BTUs per hour or 3 516 Kilowatts and 0 75 kilowatt hour is equal to one ton of refrigeration Max Heat Dissipation fully loaded SYSTEM INPUT POWER REQUIREMENTS ANALOG SERVICES NETWORK SERVICES SPECIFICATION 3300 CONTROLLER UNIT ASU UNIT NSU STREAMLINE Input Disconnect IEC320 C14 Class 1 IEC320 C14 Class 1 IEC320 C14 Class 1 IEC320 C14 Class 1 AC Receptacle 2 AC AC Receptacle AC Receptacle AC Receptacle Receptacles on AX and MXe III with redundant power Input Voltage Frequency Rating 100 240 VAC 100 240 VAC 100 240 VAC 100 240 VAC 50 60 Hz 50 6
3. 1 source supported Paging 1 paging zone System Fail Transfer 2 circuits Analog trunks support CLASS Signaling for North America and Latin America ETSI Class for international markets The Analog Line card is available in two variants the 24 ONS circuit card and the 4 LS trunks and 12 ONS extension card Note the 4 12 Card supports 4 SFT circuits Supports up to 192 ET2 channels when being used in a Trunking Gateway configuration 8Up to 999 controllers can be clustered as a single system to support over 65 000 IP ports Mitel s MiVoice Business System Data Synchronization technology is used to enable feature transparency across a cluster of controllers Up to 748 mailboxes can be used for users or multi level auto attendant Two mailboxes are reserved for Administration MITEL 3300 CXI Il CONTROLLER DATA CONNECTIVITY Integral 16 port powered Layer 2 10 100 Ethernet switch with embedded 802 af support HAS AN ADDITIONAL GIGE CAPABLE LAN PORT Provides connection to additional switch ports and router ALSO HAS A 10 100 WAN PORT THAT IS AN INTERNET GATEWAY WAN port provides connection to an ISP for Internet access e g DSL or cable WAN port provides NAT and firewall capabilities WAN port does not support IP networking USE EXTERNAL ROUTER FOR IP NETWORKING Same as you would with a CX II MXe Ill AX Controller SIP LINESIDE AND TRUNKING SPECIFICATIONS Please see the SIP CoE MCD RFC specifications document on Mi
4. 0 Bays OD N za NO NO OJ NO OJ N NO OJ NO Tone generators 128 128 128 128 Tone detector circuits 32 E2T Channels 64 128 128 DTMF Receivers 128 128 192 128 IP Networking maximum IP trunks 2000 2000 2000 2000 between MiVoice Business systems IP Networking total max IP trunks 2000 2000 2000 2000 SIP Trunking total maximum SIP trunks 2000 2000 2000 2000 SIP trunking max SIP trunks 2000 2000 2000 2000 between peers Maximum controllers in a cluster 999 STP and RSTP YES YES YES lt mi WN 2 MITEL DATA SHEET DATA SHEET MITEL MiVOICE BUSINESS 3300 CONTROLLERS VOICE MAIL SPECIFICATIONS 3300 CX II 3300 MXe Ill 3300 MXe Ill SPECIFICATION 3300 CXI II STANDARD EXPANDED 3300 AX Embedded voice mail ports as standard 20 20 Maximum embedded Voice mail ports 30 20 Maximum mailboxes 750 750 750 0 Storage hours 30 with SSD 130 130 with SDD 130 130 with SDD 130 25 with HDD with HDD with HDD Maximum messages per mailbox 100 100 100 Engineering rules apply For low traffic solutions like Hospitality systems up to a maximum of 576 devices will be supported 288 analog devices and up to 288 IP devices For systems of this size please refer to Mitel system engineering The Maximum Analog device limit is a nominal figure that depends on the Hardware used to connect the Analog devices Options include the ASU II and the SX200 Peripheral Bay Cabinet Includes Music on Hold
5. 0 Hz 50 60 Hz 50 60 Hz Input Power CX II CXi II 250 W ASU 75 W max NSU 20 W R2 24 Port 16 5W MXe III 200 W MXe III ASU Il 125 W max NSU 30W 48 Port 22W Expanded 250 W AX 300 W AC Source 90 264 VAC 90 264 VAC 90 264 VAC 90 264 VAC Frequency Range 47 63 Hz 6 63 HZ 67 63 Hz 67 63 Hz For more technical specifications on the StreamLine please refer to the StreamLine Data Sheet at mitel com streamline MITEL MiVOICE BUSINESS 3300 CONTROLLERS 5 DATA SHEET MITEL MiVOICE BUSINESS 3300 CONTROLLERS GLOSSARY ACD ASU BRI BTU CAS CCS CIM CLASS DASSII DID DDI DNI DPNSS DSP DTMF FIM IP ISDN LS MMC MOH MSDN NFAS Automatic Call Distribution Analog Services Unit Basic Rate Interface British Thermal Unit Channel Associated Signaling Common Channel Signaling Copper Interface Module Custom Local Access Signaling Services Digital Access Signaling System 2 Direct Inward Dial Direct Dial In Digital Network Interface Digital Private Network Signaling System Digital Signal Processor Dual Tone Multi Frequency Fiber Interface Module Internet Protocol Integrated Services Digital Network Loop Start Trunk MITEL Mezzanine Card Music on Hold Mitel Superswitch Digital Network Non Facilities Associated Signaling MITEL SIMPLY COMMUNICATING mitel com x MITEL GLOBAL HEADQUARTERS Tel 1 613 592 2122 Fax 1 613 592
6. 4784 Tel 1 480 961 9000 Fax 1 480 961 1370 NSU OPS PRI QSIG RSTP SIP STP T38 VM XNET TRUNKING GATEWAY USER GATEWAY 3300 CONTROLLER EMEA Network Services Unit Off Premises long loop analog PBX ports Primary Rate Interface ISDN Q Signaling Protocol Rapid Spanning Tree Protocol Session Initiation Protocol Spanning Tree Protocol ITU protocol to send FAX transmission across IP Networks Voice Mail Switched Networking A 3300 Controller used specifically to land PSTN trunks and route them onto a User Gateway A 3300 Controller Server used specifically to manage and control Telephones External traffic is routed via a Trunking Gateway Mitel s telephony platform that runs Mitel MiVoice Business formerly Mitel Communications Director MCD 11 1313 CALA ASIA PACIFIC Tel 44 0 1291 430000 Tel 1 613 592 2122 Tel 61 0 2 9023 9500 Fax 44 0 1291 430400 Fax 1 613 592 7825 Fax 61 0 2 9023 9501 FOR MORE INFORMATION ON OUR WORLDWIDE OFFICE LOCATIONS VISIT OUR WEBSITE AT MITEL COM OFFICES THIS DOCUMENT IS PROVIDED TO YOU FOR INFORMATIONAL PURPOSES ONLY The information furnished in this document believed by Mitel to be accurate as of the date of its publication is subject to change without notice Mitel assumes no responsibility for any errors or omissions in this document and shall have no obligation to you as a result of having made this document available to you or based upo
7. evices are not line powered from the embedded BRI module Note This module does not support U interfaces MITEL STREAMLINE 24 PORT OR 48 PORT VERSIONS Ethernet services over two wires Power over Ethernet Cat 3 or better cabling Upto 1200 ft Simple deployment with a station side dongle delivering Ethernet services and power DIMENSIONS ANALOG SERVICES NETWORK SERVICES SPECIFICATION 3300 CONTROLLER UNIT ASU UNIT NSU STREAMLINE Height CX Il CXI II MXe Ill ASU 1 75 in 1 75 in 4 454 cm 1 75 in 4 454 cm 3 5 in 8 9 cm 2U 4 454 cm 1 U 1 U 1 U AX 13 35 in ASU II 3 3 in 8 4 cm 39 90 cm 7 U 2 U Width CX Il CXI Il MXe Ill 17 75 in 45 1 cm 17 75 in 45 1 cm 17 13 in 43 5 cm 1715 45 10m 19 in rack mountable 19 in rack mountable 19 in rack mountable 19 in rack mountable AX 17 4 in 44 20 cm Depth CX II CXi Il 16 5 in ASU 15 5 in 15 5 in 39 4 cm 9 92 in 25 2 cm 41 9 cm MXe Ill 39 4 cm ASU II 20 25 in 51 4 cm 13 3 in 33 8 cm AX 13 87 in 35 23 cm Weight CX Il CXi Il 19 8 Ib ASU 10 61 Ib 8 41 lb 4 27 kg 7 96 Ib 3 61 kg 8 98 kg MXe IIl 4 81 kg ASU II 28 Ib 12 7 kg 14 1 Ib 6 4 kg AX 39 70 Ib 18 01 kg 4 MITEL DATA SHEET DATA SHEET MITEL MiVOICE BUSINESS 3300 CONTROLLERS OPERATIONAL ENVIRONMENT ANALOG SERVICES NETWORK SERVICES
8. n the information it contains Copyright 2013 Mitel Networks Corporation All Rights Reserved M MITEL design is a registered trademark of Mitel Networks Corporation All other products and services are the registered trademarks of their respective holders
9. ngle and Dual T1 E1 Quad BRI Quad DSP DSP Il and Echo Canceller Single and Dual T1 E1 Quad BRI Quad DSP DSP and Echo Canceller Quad BRI Quad DSP DSP Il and Echo Canceller DATA SHEET MITEL MiVOICE BUSINESS 3300 CONTROLLERS MITEL 3300 CONTROLLERS CONT D 3300 CX II 3300 MXe Ill 3300 MXe lll SPECIFICATION 3300 CXI Il STANDARD EXPANDED 3300 AX 10 100 1000 MB Ethernet ports See CXi Controller Data 2 connectivity section 2 10 100 only Maximum Quad DSP or DSP II modules 0 1 NO m xwe Maximum Echo Canceller Channels 192 128 Orv wW aR NO IN UJ UJ NO OY NO a NO gt UJ NO Maximum G 729a compression channels 64 with DSP II 128 192 128 DSP II 128 Quad DSP 32 Dual DSP 16 Maximum T38 channels Maximum number of NSU s 2 R2 NSU only Ea Maximum number of digital links except BRI 2 NO D Maximum Embedded BRI interfaces 2 channels per interface Maximum number of Dual FIM modules NO oO Dual FIM can be used to connect NSU DSU Peripheral NSU DSU Peripheral Cabinets Triple FIM Cabinets Triple FIM card and SX200 Bay card and SX200 Bay Analog Main Board 6 LS trunks 4 ONS ports 6 LS trunks 4 ONS ports 6 LS trunks 0 4 ONS ports oO Analog Option Board 6 LS trunks 4 ONS ports NO Analog Line card slots Maximum number of CIM connected ASU s 3 Maximum number of Fiber and Copper connected SX20
10. tel OnLine for up to date SIP specification support MITEL MiVOICE BUSINESS 3300 CONTROLLERS 3 DATA SHEET MITEL MiVOICE BUSINESS 3300 CONTROLLERS DIGITAL TRUNK CONNECTIVITY DUAL EMBEDDED DIGITAL TRUNK MODULE MXE II CONTROLLER AND AX CONTROLLER Each module has two E1 T1 trunk interfaces links Provides PRI QSIG T1 D4 DASS II DPNSS IDA P protocol through the controller No NSU required Each interface can run a different protocol either PRI QSIG or T1 D4 DOES NOT SUPPORT Min Max NFAS D Channel Backup or TDM XNET Hybrid XNET is supported SINGLE EMBEDDED DIGITAL TRUNK MODULE CX II CXI II MXE III AX CONTROLLERS Each module has a single E1 11 trunk interface link Provides PRI QSIG T1 D4 DASS II DPNSS IDA P protocol through the controller No NSU required Resiliency switches to secondary controller DOES NOT SUPPORT Min Max NFAS D Channel Backup or TDM XNET Hybrid XNET is supported EMBEDDED BRI MODULE CX II CXI II MXE III AX CONTROLLERS The Embedded BRI module has four Basic Rate Circuits total 8 64kbs channels EACH CHANNEL MAY BE CONFIGURED AS EITHER A T trunk interface for links from a BRI Central Office CO S subscriber interface for connecting up to eight BRI devices Note S interfaces support only basic call features such as calling number display for BRI devices BRI call handling such as Hold or Transfer are not supported BRI d
Download Pdf Manuals
Related Search
Related Contents
GAME AIR - Acrylicos Vallejo GB Drill Instruction Manual F Perceuse Manuel d SH7058 E6000H Emulator HS7058EPH60H, SH7058S, SH7059 electric food chopper - use instructions • universalzerkleinerer 取扱説明書 wellness4one Trainer User Manual Manual de Instalación de un componente como servicio. pastourelle n° 69 – le secteur paroissial – mode d`emploi 取扱説明書・工事説明書 Maytag Cooktop JGD8130ADS User's Manual Copyright © All rights reserved.