Emerson PSA1000MT3-120U uninterruptible power supply (UPS)
Contents
1. Step 4 Start the UPS After the battery is fully charged e Turn on the UPS by pressing the On Off button see Figure 1 below LED 1 should be illuminated green indicating the UPS is operating in Normal Mode UPS CONTROLS AND CONNECTIONS Figure 1 Front Panel LEDs LED3 LED4 amber red LED1 LED2 green amber On Off button EMERSON Network Power e Connect the UPS only to an earthed grounded outlet that meets national and local electrical safety guidelines e Locate the UPS near a wall outlet Do not use an extension cord between the UPS and the outlet e The Liebert PSA has been designed for small office nome office use only it is NOT recommended for use in life support applications e Inthe event of an emergency press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS e Do not attach power strips or surge suppressors to the UPS e Do not attempt to service any parts inside the UPS except the batteries Failure to adhere to this could cause personal injury or equipment malfunction and void the warranty e For technical support e Visit www liebert com or e Send an e mail to upstech emersonnetworkpower com Step 5 Check the Site Wiring Fault Indicator See figure at right for the location of the Site Wiring Indicator on the rear of the UPS e Check the rear of the UPS to make sure the Site Wiring Fault indicator is NOT illuminated Caution If
2. Corporation 800 222 5877 Outside U S 614 841 67 55 1050 Dearborn Drive EMERSON Alnames referred to are trademarks or registered trademarks of their respective owners upstech emersonnetworkpower com P O Box 29186 i r SL 23301 REVO 04 08 Web site www liebert com Columbus OH 43229
3. the Site Wiring Fault indicator is illuminated have a qualified electrician check the wall receptacle wiring and fix any problems Step 6 Connect the Loads The UPS has three battery backup outlets that provide power when the UPS operates on battery see Figure 2 below e Plug the loads into the battery backup outlets on the rear of the UPS Caution Do not connect a laser printer to the UPS ANKEET Step 7 Connect the Network Surge Protection The UPS has two RJ 45 jacks for network lines see Figure 2 below e Connect a single line network cable into the RJ 45 network surge protection IN jack on the rear of the UPS e Connect an RJ 45 cable from the OUT jack on the rear of the UPS to a port on a PC or network device such as a router Step 8 Set Up Liebert shutdown software To start using the Liebert shutdown software e Install the Liebert shutdown software See the software user manual for installation instructions e Connect one end of the USB cable supplied to the USB port on the rear of the UPS Connect the other end to a USB port on the computer See the software user manual for operating instructions Figure 2 Rear Panel USB aE a interface Site Wiring Fault indicator USB SITE WIRING FAULT RJ 45 jacks 2 vea network protection Utility Fault Sattery pears symbol symbol outlets i NEMA 5 15R Surge outlets 2 a NEMA 5 15R Battery Overload sym bol sym bo Fu
4. Liebert PSA Quick Start Guide 1000VA 1500VA 120V IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS Intended for installation in a controlled environment e Maximum ambient temperature 104 F 40 C A CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent protection in accordance with the national code ANSI NFPA 70 e Do not connect equipment that may overload the UPS or demand half wave rectification such as a laser printer SETUP Step 1 Inspect the package and the UPS upon receipt Notify the carrier and dealer of visible damage Inspect the Package Liebert shutdown software CD Quick start guide UPS Step 2 Decide Where to Place the UPS The UPS must be placed indoors protected from water direct sunlight and excessive heat Provide at least 4 100mm of clearance on all sides of the unit for proper ventilation Step 3 Charge the UPS Battery Before Use The UPS battery is not charged before shipping It MUST be charged before use e Connect the UPS power cord to a wall outlet and charge for at least eight hours Note If battery is placed in storage charge the battery every six months if kept at 5 F to 85 F 15 C to 29 C or every three months if kept at 86 F 30 C or higher
5. erminal D A M ST TT Steps 4 and 5 Note Small sparks may occur at the battery connectors during reconnection 8 Slide the batteries into the UPS 9 Reposition the front panel and slide downward until it slides into place Slide the top panel forward until flush with the front panel Reinsert the two top cover screws removed in Step 2 uw Lu Dispose of the old batteries properly at an appropriate recycling facility TROUBLESHOOTING If the UPS malfunctions during operation check the following chart for proper adjustment For further assistance please contact your local Emerson Network Power representative Problem Possible Causes Solutions The UPS may not be turned on e Press the On Off button to turn on the UPS Utility power is normal but LED 1 is not illuminated The power cord may not be connected properly e Connect the power cord securely into a wall outlet The upstream input circuit breaker may be tripped e Reset the input circuit breaker LED 2 flashes amber every 3 seconds but there is Battery voltage may be too low e Recharge the UPS for 8 hours no output power ah j o CON IOUR y AONE Y The UPS may be
6. ll Time Surge Protection N l t ACINGDTE AC OUTPUT YY npu Y breaker EMERSON Liebert PSA mir Network Power AC Power System NEMA 5 15P UPS Status Alarm Conditions and Alerts Normal Mode LED Solid steady glow Battery Mode LED 2 Flashes every 3 seconds Every 3 seconds Battery Low LED 2 Flashes every 1 second till end of discharge EOD Every 1 second LED 3 Solid steady glow until load drops or breaker trips Continuous Battery Replacement LED 4 Red Flashes every 1 second for 5 seconds only Every 1 second for 5 seconds only LED 4 Red Solid steady glow until UPS shuts down after 5 seconds Continuous until UPS shuts down REPLACING THE BATTERY To replace the battery 1 Turn off all connected loads then turn off the UPS batteries are NOT hot swappable 2 Use a Phillips head screwdriver to remove the two top cover screws from Steps 2 and 3 the back of the UPS l lt 3 Slide the top panel backward 1 2 13mm Slide the front panel upward then pull outward to remove it 4 Gently pull the batteries out of the UPS 5 Remove the black wire from the negative terminal and the red wire from the positive terminal Be 6 Verify that the replacement battery matches the dimensions and battery 1 type in the Specifications section below AY a 7 Connect the battery leads to the new batteries Be sure to reconnect the red wire to the positive terminal and the black wire to the negative t
7. overloaded check LED 2 Disconnect some equipment from the UPS UPS does not provide expected backup time The UPS battery reached end of life e Replace the internal battery The UPS is on and connected to input power but fails 7 e e If utility power is normal try reconnecting input Utility power may be outside the unit s operating range to operate properly power and restarting the UPS 0 lt m O gt O Z U Model Number PSA1500MT3 120U Capacity VA W 1500 900 Net Weight Ib kg 27 8 12 6 Shipping Weight Ib kg 30 0 13 6 Dimensions W x D x H in mm 5 8 x 14 2 x 9 2 147 x 360 x 234 84 140VAC 50 60Hz 5Hz Typical 97 129VAC Output Voltage Battery Operation 120VAC 5 On Line Input Voltage On Line Frequency Output Voltage Mains Normal On Battery Wave Form Stepped sinewave 12V x 7Ah x 2 Battery Type VDC x Ah x Quantity 12V x 9Ah x 2 6 8 hours to 90 Typical Recharge Time Battery Run Time Full Load 6 minutes Operating Storage Relative Humidity 0 90 non condensing EMI Classification FCC Part 15 Class B Agency Safety UL 1778 c UL Listed Transportation ISTA Procedure 1A Certification Battery run time may vary depending on load A 2008 Liebert Corporation Technical Support Service United States amp S All rights reserved throughout the world Specifications subject to change without notice Liebert is a registered trademark of Liebert
Download Pdf Manuals
Related Search
Related Contents
Descodificador GOLD 10432-33 Netgear WN370 Installation Guide Gas Flow Standards ねじ蔵 カタログ フロン回収業者の登録の手引き 取扱説明書 - M 就業支援課(PDF:448KB) GEBRAUCH SANWEIS|UNG OPERATING INSTRUCTIONS 1:250 000 Scale Colour Raster user guide and technical spec CDMA 2000 1x Based EVDO Rev A Data Card Make Copyright © All rights reserved.