IBM UPS 6000VA LCD

image

Contents

1. 28 4 in Weight 59 kg 130 Ib Operating environment The IBM 6000VA LCD 4U Rack UPS is supported in the following environment Maximum operating altitude 3 048 m 10 000 ft Maximum storage altitude 15 240 m 50 000 ft Operating temperature at 0 to maximum altitude 0 C to 40 C 32 F to 104 F 24 hour transport storage temperature at 0 to maximum storage altitude 15 C to 60 C 5 F to 140 F Extended storage temperature at 0 to maximum storage altitude 15 C to 45 C 5 F to 113 F Relative humidity 0 to 95 noncondensing Warranty The IBM 6000VA LCD 4U Rack UPS has a three year limited warranty IBM 6000VA LCD 4U Rack UPS 5 Supported rack installation The IBM 6000VA LCD 4U Rack UPS requires 4U of rack space in one of the following rack cabinets IBM 42U Enterprise rack IBM S2 42U Dynamic rack IBM S2 42U rack IBM S2 25 U rack IBM 11U Office Enablement kit Front panel controls With a bright and easy to navigate panel that provides configurability and displays important status information the IBM 6000VA UPS is easy to manage and an ideal solution for standardization across the global enterprise Runtime load and other vital information and troubleshooting are also displayed Figure 2 shows the front panel of the UPS Current load onthe UPS NN graphical and numeric on OUHZ UPS ON Overall status Figure 2 Front panel showing System Status IBM 6000VA LCD 4U Rack UPS The following
2. functions are available on the control panel System status Displays the battery status load percentage output power output voltage and frequency mode notice or alarm status Alarm history Displays the alarm history for the 50 most recent events Meters Displays the output watts VA current power factor voltage frequency input voltage input frequency battery voltage and percentage charged Control screens Displays the battery test reset error state configure load segments and restore settings Model information Displays the machine type model and serial number of the unit as well as the firmware level of the UPS including the optional Network Management Card s firmware level and IP address if installed Configuration Allows you to change up to 17 user settings with minimal navigation The buttons have the following functions Escape X Press this button to return to the previous menu without running a command or saving any changes Down Press this button to scroll down to the next menu option OK Press this button to select the current menu or option On off Press this button to turn on the UPS Press and hold this button for 3 seconds to turn off the UPS On some screens the OK button has an additional function if you press and hold the button longer than 1 second On the User Setting screens to save the displayed setting On the Meter and Notice Alarm screens to lock the screen prevent
3. 0 VA 5600W 208V AC Two Two NEMA L6 30R Four IEC 320 C19 184 228V 208V 208V 50 60 Hz 3 Hz 50 60 Hz 3 Hz Hard wired to terminal block Hard wired to terminal block None None 155 255V for 208V 160V 286V for 230V See Table 3 See Table 3 Valve Regulated Lead Acid VRLA maintenance free sealed leak proof Yes 69Y1984 Yes 69Y1984 4 hours to 90 charge from a UPS battery discharge of 50 rated load es Yes Yes Yes Optional using Network Management Card 46M4110 Optional Environmental Monitoring Probe 46M4113 1300 Joules 1300 Joules ANSI IEEE C62 41 1991 CATEGORYB3 SURGE Battery run times and recharge times Table 3 lists the expected period that the 6000VA UPS will operate solely on batteries The run times for the 230V model are the same as the 200 208V model Table 3 IBM 6000VA UPS runtime chart Percent Load VA Watts Run time with standard internal Run time with internal battery plus battery only External Battery Module EBM Note Battery backup times are approximate and may vary with equipment configuration battery age and temperature Physical specifications The physical specifications of the 4U uninterruptible power supply are as follows Height 172 mm 6 8 in Width 483 mm 19 in Depth 735 mm 28 9 in Weight 72 kg 159 Ib The physical specifications of the 3U Extended Battery Module are as follows Height 127 mm 5 0 in Width 483 mm 19 in Depth 721 mm
4. 5 RU4 FC 6661 IBM 6000VA UPS 3U Extended Battery Module EBM 69Y 1984 5395 RU4 FC 5734 IBM LCD UPS Network Management Card optional 46M4110 6145 IBM LCD UPS Environmental Monitoring Probe optional 46M4113 6146 The UPS models include the following items e Anaccessory kit containing the following items Front bezel Rack mount kit with rails and hardware including 4 post rail kit Serial cable 3 7 m 12 ft USB cable Remote emergency power off REPO connector documentation kit containing the following items A e Warranty flyer and Important Notices Manual e Documentation CD e Software CD which contains IBM UPS Manager power management software The UPS does not include an input line cord The line cord is hard wired to a terminal block on the rear of the UPS A licensed electrician will need to connect the units to a dedicated branch circuit Circuit requirements are listed in the BM 6000 VA UPS and 6000 VA EBM Installation and Maintenance Guide IBM 6000VA LCD 4U Rack UPS 2 Features The IBM 6000VA LCD 4U Rack UPS has the following features and capabilities IBM 6000VA LCD 4U Rack UPS Occupies only 4U of vertical rack space Has over 95 energy efficiency at 100 load Offers six or 10 output receptacles e Model 5395 6AX 200V 208V has two NEMA L6 30R and four IEC 320 C19 receptacles e Model 5395 6KX 230V has four IEC 320 C19 and six IEC 320 C13 receptacles Bundled intelligent IBM UPS Manager sof
5. A LCD 4U Rack UPS 15 IBM Environmental Monitoring Probe EMP The Environmental Monitoring Probe EMP part number 46M4113 is used to report local temperature and humidity values and make that information available to management tools such as IBM Systems Director Active Energy Manager AEM The EMP connects to the UPS via the Network Management Card The EMP is shown in Figure 12 Figure 12 IBM Environmental Monitoring Probe EMP The Environmental Monitoring Probe has the following characteristics It connects to the Network Management Card NMC settings sensor connection Its temperature and humidity thresholds are easily set to trigger alarm notifications or shut down the protected system Its status can be monitored from the IBM Systems Director AEM or from the Network Management Card web interface It measures temperatures between 0 and 80 C 32 and 176 F with an accuracy of 1 C It measures relative humidity between 10 and 90 with an accuracy of 5 It can be located away from the UPS with a CAT5 network cable up to 20 m 65 6 ft Its user selectable alarm thresholds enable you to define acceptable temperature or humidity limits It allows email notification through SMTP Figure 13 shows information retrieved from an EMP using the NMC web interface IBM 6000VA LCD 4U Rack UPS Network Management Card Max 32 2 recorded on 20100404 08 50 11 Enw onmem Figure 13 Environmental Monitoring Probe dat
6. Ih T ae Redbooks web Doc IBM 6000VA LCD 4U Rack UPS IBM System x at a glance guide The IBM 6000VA LCD 4U Rack uninterruptible power supply UPS delivers 5600 watts of power in only 4U of rack space providing smart energy management and the highest level of power protection that today s IT infrastructures require With an efficiency rating of 95 or greater the UPS helps reduce energy usage and cooling costs improves energy management and optimizes workload performance and availability for IBM System x and BladeCenter server applications This high density UPS packs more real power watts into a space saving 4U of rack space to protect more equipment and leaves room for expanding IT systems The IBM 6000VA LCD 4U Rack UPS is shown in Figure 1 Figure 1 IBM 6000VA LCD 4U Rack UPS for IBM System x Did You Know The IBM 6000VA UPS has a bright easily customizable and graphical LCD display that lets you configure the device and displays important UPS status information in one of nine languages English French German Spanish Russian Korean Japanese Simplified Chinese and Traditional Chinese The UPS is exceptionally easy to manage and an ideal solution for standardization across the global enterprise This UPS enhances system availability with Advanced Battery Management ABM technology This technology significantly extends battery service life allows individual control of receptacle groups to maximize run time for c
7. Network Management Card e Allows simultaneous shutdown of protected servers e Allows configuration of automatic email messages in response to UPS alarms and to transmit periodic reports see Figure 8 e Allows control of UPS on off switching with a web browser e Allows adjustment and control of load segments through the HTML interface including sequential starting of the installation and optimization of backup time by shutting down non priority systems e Allows protection by using an encrypted password e Allows protection by using a secure SSL connection e Allows log storage in the nonvolatile memory e Allows card firmware updates through the network e Allows fast Ethernet 10 100 Mbps compatibility with auto negotiation on the RJ 45 connector e Allows recording of events and measurements in the card log e Has a humidity temperature dry contact sensor optional EMP e Has support for IPv6 e Can be installed while the UPS is online maintaining the highest system availability Figure 8 shows the Network Management Card UPS properties window IBM 6000VA LCD 4U Rack UPS 11 Network Management Card IBM 2200VA1920W Rack HV UPS Computer Room Logs and Hotification About your UPS Settings Figure 8 IBM LCD UPS Network Management Card NMC UPS properties window IBM UPS Manager Software The UPS comes with the IBM UPS Manager software The management software provides up to date graphics of UPS power and system data and p
8. VA LCD 4U Rack Uninterruptible Power Supply Installation and Maintenance Guide http ibm com support entry portal docdisplay Indocid MIGR 5085548 Network Management Card User Guide http ibm com support entry portal docdisplay Indocid MIGR 5085199 IBM System x Configuration and Options Guide http ibm com support entry portal docdisplay Indocid SCOD 3ZVQ5W IBM 6000VA LCD 4U Rack UPS Notices This information was developed for products and services offered in the U S A IBM may not offer the products services or features discussed in this document in other countries Consult your local IBM representative for information on the products and services currently available in your area Any reference to an IBM product program or service is not intended to state or imply that only that IBM product program or service may be used Any functionally equivalent product program or service that does not infringe any IBM intellectual property right may be used instead However it is the user s responsibility to evaluate and verify the operation of any non IBM product program or service IBM may have patents or pending patent applications covering subject matter described in this document The furnishing of this document does not give you any license to these patents You can send license inquiries in writing to IBM Director of Licensing IBM Corporation North Castle Drive Armonk NY 10504 1785 U S A The following paragraph does not apply
9. a as viewed from the Network Management Card web interface IBM Systems Director Active Energy Manager IBM Systems Director Active Energy Manager AEM provides an array of new features that allow power and thermal trending analysis for improved power management AEM collects power information for each device attached to an IBM UPS presenting a more complete view of energy usage within the data center The IBM Systems Director Active Energy Manager AEM helps e Collect power information from each device attached to an IBM UPS thus presenting a more complete view of energy usage e With server consolidation plans because of the increased server and rack power densities that have driven the requirement for advanced power management solutions e n combination with the optional Environmental Monitoring Probe AEM enables cross platform power and thermal trending analysis for improved power management This configuration allows IT and facility managers to manage data centers for optimal energy efficiency migrate workloads to eliminate hot spots and transfer work from underutilized systems to conserve energy IBM 6000VA LCD 4U Rack UPS Related publications For more information refer to these documents IBM US Product Announcement http ibm com common ssi cgi bin ssialias infotype dd amp subtype ca amp amp htmlfid 897 ENUS 110 159 IBM System x UPS product page http www ibm com systems x hardware options upsrack html IBM 6000
10. ature and humidity which requires that the Network Management Card be installed Offers an Advanced Battery Management ABM three stage charging technology significantly extends battery service life and optimizes recharge time The three stages are 1 The battery is quickly charged to 90 to make sure the UPS is prepared for the next outage 2 ABM finishes charging the battery with a more moderate float charge 3 After the battery is charged ABM turns the charger off thereby preventing the batteries from being overcharged Specifications Table 2 lists the specifications for the three 6 000VA UPS models Table 2 Specifications Part 1 of 2 Specification IBM part number VA Watts rating Nominal output voltage Vac Load groups Output connections Nominal output voltage regulation Nominal input voltage auto sensing at first power up Input frequency auto sensing Input connection Type Included line input cords Input voltage range mains operations Batteries Typical backup times Battery type Optional External Battery Pack Typical recharge time Communications and management USB port RS 232 serial port Ethernet port Environmental Monitoring Probe Surge Protection and Filtering Surge energy rating Filtering IBM 6000VA LCD 4U Rack UPS IBM 6000VA LCD 4U Rack UPS 200V 208V IBM 6000VA LCD 4U Rack UPS 230V Four IEC 320 C19 Six IEC 320 C13 208 253V 230V 230V 5395 6AX 600
11. ease the number of power sockets available to servers while still being under the control and security of the uninterruptible power supply Figure 5 shows an example configuration Fixed NEMA L6 30P line cord IBM 6000VA LCD UPS 200 208V 5395 6AX IBM 42U rack IBM OU 24x C13 30A a PDU 46M4128 Figure 5 Sample configuration showing use of the 6000VA LCD 4U Rack UPS 200 208V with a PDU IBM 6000VA LCD 4U Rack UPS IBM UPS 3U Extended Battery Module For applications requiring extended backup times an external battery module can also be added to the 6000VA models to deliver hours of run time to critical systems during a prolonged power outage The IBM 3U Extended Battery Module EBM is a 3U rack mounted device that contains additional batteries Tables 4 to 6 show the additional run times achieved with the EBM connected Figure 6 shows the front of the 3U Extended Battery Module Figure 6 IBM 6000VA UPS 3U Extended Battery Module EBM Network Management Card The IBM 6000VA LCD 4U Rack UPS also comes equipped with a communication bay for the installation of an optional Network Management Card 46M4110 The Network Management Card provides convenient over the network UPS remote monitoring and management through a standard web browser Figure 7 shows the IBM LCD UPS Network Management Card NMC Figure 7 IBM LCD UPS Network Management Card NMC IBM 6000VA LCD 4U Rack UPS 10 The IBM LCD UPS
12. face for the operating platform for which the sample programs are written These examples have not been thoroughly tested under all conditions IBM therefore cannot guarantee or imply reliability serviceability or function of these programs Copyright International Business Machines Corporation 2010 All rights reserved Note to U S Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp IBM 6000VA LCD 4U Rack UPS 19 This document was created or updated on April 19 2011 Send us your comments in one of the following ways e Use the online Contact us review form found at ibm com redbooks e Send your comments in an e mail to redbook us ibm com e Mail your comments to IBM Corporation International Technical Support Organization Dept HYTD Mail Station P099 2455 South Road Poughkeepsie NY 12601 5400 U S A This document is available online at http www ibm com redbooks abstracts tips0793 html Trademarks IBM the IBM logo and ibm com are trademarks or registered trademarks of International Business Machines Corporation in the United States other countries or both These and other IBM trademarked terms are US registered or common law trademarks owned by IBM at the time this information was published Such trademarks may also be registered or common law trademarks in other countries A current list of IBM trademarks is available on the Web at http www
13. ibm com legal copytrade shtml The following terms are trademarks of the International Business Machines Corporation in the United States other countries or both BladeCenter IBM Systems Director Active Energy Manager IBM Redpaper Redbooks logo System x Other company product or service names may be trademarks or service marks of others IBM 6000VA LCD 4U Rack UPS 20
14. m the accuracy of performance compatibility or any other claims related to non IBM products Questions on the capabilities of non IBM products should be addressed to the suppliers of those products This information contains examples of data and reports used in daily business operations To illustrate them as completely as possible the examples include the names of individuals companies brands and products All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental Any performance data contained herein was determined in a controlled environment Therefore the results obtained in other operating environments may vary significantly Some measurements may have been made on development level systems and there is no guarantee that these measurements will be the same on generally available systems Furthermore some measurement may have been estimated through extrapolation Actual results may vary Users of this document should verify the applicable data for their specific environment COPYRIGHT LICENSE This information contains sample application programs in source language which illustrate programming techniques on various operating platforms You may copy modify and distribute these sample programs in any form without payment to IBM for the purposes of developing using marketing or distributing application programs conforming to the application programming inter
15. ower flow It also gives you a complete record of critical power events and notifies you of important UPS or power information If there is a power outage and the UPS battery power becomes low the software can automatically shut down the system to protect the data before the UPS shutdown occurs Figure 9 shows normal operating using the IBM UPS Manager The input voltage is 122V which is within the acceptable range and is shown in the left pane The output voltage of the UPS is 121V and is also within the acceptable range The battery is in floating mode which is the second stage of the Eaton Advanced Battery Management ABM three stage charging technology IBM 6000VA LCD 4U Rack UPS 12 EJ IBM UPS Manager An oM Controller RA1NCWE0067515J 10 222 45 44 UPS model IBM UPS 1000VA to 3000VA input Voltage d UPS Status i Output Voltage A i 180 Soe LJ R A i ee ie ee a de a 160 Filt 4 120 100 80 60 40 20 0 i 121 VAC ABM Floating Event Status Q Normal 7 2 2010 1 42 41 PM There are no active alarm events pending Figure 9 IBM UPS Manager normal status window IBM 6000VA LCD 4U Rack UPS Figure 10 shows that the utility power supply has failed and that the UPS is now operating on battery The UPS Manager software indicates that there is 10 minutes of battery time available based on the current load EA IBM UPS Manager File Yew Configuration Shutdown Disgnostics Lops Network Operation
16. ritical devices in the event of a prolonged power outage provides a real time clock that enables precise shutdown and power up of systems in a preferred sequence and records specific power related occurrences for more accurate trending and data analyses The IBM 6000VA UPS integrates with IBM Systems Director Active Energy Manager to help improve energy management IBM 6000VA LCD 4U Rack UPS 1 About uninterruptible power supplies An uninterruptible power supply UPS is a device that acts as a defensive barrier between electronic equipment and incoming power problems It conditions regulates and filters out power disturbances to ensure a clean power source for IT equipment A UPS also provides battery backup in the event of a power failure In today s high availability server environments unplanned power outages or line quality irregularities can have a considerable financial impact on businesses of all sizes The typical utility power is 99 9 available but that means that there can be almost 9 hours of downtime a year not to mention brown outs and other power quality problems Selecting the right IBM UPS can help protect against these potentially costly incidents Part number information Table 1 lists the orderable part numbers and feature codes for the IBM 6000VA UPS Table 1 Ordering part numbers and feature codes IBM 6000VA LCD 4U Rack UPS 200 208V 5395 6AX 5395 RU4 FC 6660 IBM 6000VA LCD 4U Rack UPS 230V 5395 6KX 539
17. s Help Oe STON Controller RAINCWE0067515J 10 222 45 44 UPS model IBM UPS 1000VA to 3000VA Input Voltage UPS Status Output Voltage Event Status Q Warning 7 2 2010 2 26 57 PM Q Warning 7 2 2010 2 26 57 PM Q Warning 7 2 2010 2 26 57 PM Figure 10 IBM UPS Manager warning status window IBM 6000VA LCD 4U Rack UPS 14 Figure 11 shows the event notification window where you can configure how you and other users want to be notified when certain events occur Event Notification lt Alert Type Message text Controller shutdown pending The Controller will shut down in MINUTES minutes Shutdown in 1 minute Shutdown cancelled Shutting down Controller communications lost fo seconds Controller communications established Power Monitor loaded E mail a TR deast AN eil Power Monitor unloaded Diagnostic test reminder IV Enable e mail alert messaging Test Communications port unavailable Diagnostic test performed Replace battery reminder Scheduled M anual shutdown ITManager Companyrx com IBM UPS Manager software installed Minor on battery event General power anomaly counter Filter List fan Alerts v Legend Email T Command Broadcast Server Settings al _Detaut _ Cancel Apply Figure 11 Event Notification window m Notification delay on no amp wh pm E mail recipients P D amp D D D D D D D D D v IBM 6000V
18. the screen from returning to its default after timeout A locked screen displays a small key image near the status icon To unlock the screen press any button to perform its usual function IBM 6000VA LCD 4U Rack UPS Rear panel Figure 3 shows the rear panel of the IBM 6000VA LCD 4U Rack UPS 200V 208V Two NEMAL6 30R Four IEC 320 C19 Optional Network USB and receptacles receptacles Management Card senal ports Load segment 2 Load segment 1 NMC bay Extended battery Circuit breakers for Input terminal Remote emergency module EBM load segments 1 and 2 block power off REPO connector port Figure 3 Rear panel of the IBM 6000VA LCD 4U Rack UPS 200V 208V Figure 4 shows the rear panel of the IBM 6000VA LCD 4U Rack UPS 230V Four IEC 320 C19 Six IEC 320 C13 Optional Network USB and receptacles receptacles Management Card senal ports Load segment 2 Load segment 1 NMC bay Extended battery Circuit breakers for Input terminal Remote emergency module EBM load segments 1 and 2 block power off REPO connector port Figure 4 Rear panel of the IBM 6000VA LCD 4U Rack UPS 230V IBM 6000VA LCD 4U Rack UPS Use with power distribution units The 6000VA LCD 4U Rack UPS is designed to work with power distribution units PDUs such as the new IBM OU 24 C13 30A PDU which mounts vertically in a rack pocket and does not consume any of the rack units used for servers and storage PDUs allow you to incr
19. to the United Kingdom or any other country where such provisions are inconsistent with local law INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes will be incorporated in new editions of the publication IBM may make improvements and or changes in the product s and or the program s described in this publication at any time without notice Any references in this information to non IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you Information concerning non IBM products was obtained from the suppliers of those products their published announcements or other publicly available sources IBM has not tested those products and cannot confir
20. tware enhances control and manageability Supports IPv6 for future proofing IP addressing and security Includes a real time clock that enables precise shutdown and power up of systems in preferred sequence and time stamping on event logs to track and record specific power related occurrences Integrates with IBM Systems Director Active Energy Manager for power and thermal trending analysis and management Has load segments that allow for individual control of receptacle groups maximizing run time for critical devices Supports an optional network management card part number 46M4140 for enhanced UPS monitoring and control Allows dual channel communication through the USB port and optional Network Management Card at the same time which is an effective redundancy feature that maximizes communications flexibility Supports an optional Extended Battery Module EBM for increased runtime requirements Includes a Remote Emergency Power Off REPO port to remotely power off the UPS unit to prevent battery operation during a power failure Requires the following input power e Single phase circuit with a 2 pole circuit breaker e 200 208V model Requires a 40A circuit e 230V model Requires a 32A Europe or 40A North America circuit Includes hot swap batteries for maximum uptime availability and ease of maintenance Supports an optional Environmental Monitoring Probe part number 46M4113 for thermal management requirements temper

Download Pdf Manuals

image

Related Search

Related Contents

Sony Receiver STR-DE698 S  USB2DEMON USB2SPRITE USER`S MANUAL  la VAE  Starcraft Expandables Manual  STM32-P407 development board USER`S MANUAL  Goldstar MBM-2105GIA User's Manual  Palsonic DVDR160G User's Manual  Samsung SyncMaster  software installation procedures for xdcam e  Linktropy Mini2 User's Guide  