Home

Tripp Lite SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

image

Contents

1. Mode Output Voltage Regulation Battery _ RO Mode UPRA Output Receptacles 6 C13 Included Output Power Cables Includes 2 C13 to C14 output power cables Load Management Receptacles Two switchable two outlet C13 load banks Hot Swap PDU options PDUBHV10 2U 8 C13 outlets Output AC Waveform AC Mode Sine wave Output AC Waveform Battery Mode Pure Sine wave INPUT Nominal Input Voltage s Supported 230V AC UPS Input Connection Type C14 inlet IEC320 C14 input connection accepts a variety of user supplied detachable C13 output cordsets to match country or site specific power sources UPS Input Connection Description Tripp Lite ERRON 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Input Phase Single Phase BATTERY Full Load Runtime min 3 6 min 900w Half Load Runtime min 11 9 min 450w 4 Battery Recharge Rate Included Less than 4 5 hours from 10 to 90 typical full load discharge Batteries Internal UPS Replacement Battery See Tripp Lite RBC selector guide Cartridge Battery Access Front panel battery access door Battery Replacement Description Hot swappable user replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation AVR maintains line power operation with an input voltage range of 182 to 278 Overvoltage Correction Input voltages between 244 and 278 are reduced by 12 Undervoltage Correction Input voltages
2. Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartPro 230V 1000VA 900W Line Interactive Sine Highlights Wave UPS SNMP Webcard 2U Rack Tower USB Peet A eons line interactive 2U rack tower DB9 Serial UPS Sine Wave MODEL NUMBER SMX1000RT2U e 230V output Corrects brownouts and overvoltages from 182V to 278V e 0 9 Power Factor Interactive LCD interface e 4 post compatible mounting accessories e 97 line mode efficiency 2 switched load banks e USB RS232 EPO and slot for SNMPWEBCARD option e 230V C14 inlet 6 C13 outlets Package Includes e SMX1000RT2U UPS System e PowerAlert Software with USB Serial amp EPO cabling 4 post rackmount installation kit e Set of 2 C13 C14 power cables e Instruction manual Description Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network grade power protection for critical server network and telecommunications equipment Line Interactive Uninterruptible Power Supply UPS with built in Auto Voltage Regulation AVR actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure Interactive LCD interface reports UPS operating mode detailed UPS and site power data plus enables a variety of UPS setup and configuration options Super fast switchover from line to battery power occurs within milliseconds to maintain operat
3. between 182 and 206 are boosted by 12 USER INTERFACE ALERTS amp CONTROLS Front panel LCD information and configuration screen offers detailed UPS and site power status and operating Front Panel LCD Display data plus configuration of voltage operating mode alarm function and a variety of additional options see manual for detailed LCD configuration and monitoring options 3 pushbutton switches control OFF ON power status MODE selection and MUTE ENTER control functions Power fail alarm can be temporarily silenced using alarm cancel switch silent mode alarm configuration option Alarm Cancel Operation available Audible Alarm Audible alarm indicates UPS startup power failure low battery overload UPS fault and remote shutdown conditions LED Indicators 5 LEDs indicate line power battery power overload voltage regulation and battery low replace status SURGE NOISE SUPPRESSION Time EMI RFI AC Noise Suppression Yes PHYSICAL Included Mounting Accessory 4 post rackmount installation accessories included Description Installation Form Factors Supported 2 post rackmount 2POSTRMKITWM Wallmount POSTRMKITWM Tower 2 9USTAND 2 4 post front rail with Optional Accessories rackmount UPSHDEARKIT Tripp Lite ieee YY 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Primary Form Factor Rackmount UPS Power Module Dimensions hwd in 3 9 17 5X 13 5 UPS Power Mod
4. ion of connected equipment without interruption or reboot 97 line mode efficiency offers reduced heat emissions and operating costs Network management interfaces support communications via USB RS 232 and optional SNMPWEBCARD network interface HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Network communications ports enable detailed monitoring of equipment load levels self test data and utility power conditions Includes PowerAlert monitoring software and complete cabling Switched output load banks enable scheduled and real time remote reboot and load shedding of select outlets Emergency Power Off EPO interface LCD display panel easily rotates for viewing in rackmount or tower configurations Audible alarm with push button momentary alarm cancel and silent mode configuration options Programmable self test Field replaceable hot swappable batteries Features e Tripp Lite SMX1000RT2U line interactive 2U rack tower UPS with 1000VA 1kVA capacity Line interactive UPS with Automatic Voltage Regulation AVR corrects brownouts and overvoltages from 182 to 278V e C14 AC power inlet 6 C13 output receptacles Two independently switchable output load banks e Maintains uninterrupted operation of connected networking equipment during blackouts surges brownouts and overvoltages e High 97 efficiency rating in line power mode offers reduced power consumption and BTU emis
5. nternational Product Warranty Period Mexico 2 year limited warranty Sie Warranty Period Puerto 2 year limited warranty 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 9 95
6. sions e Internal batteries offer 11 9 minutes at 50 load 450W and 3 6 minutes at 100 load 900W e Hot swappable user replaceable internal batteries can be replaced with no disruption to connected equipment e Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5 bar battery charge graphic plus 7 selectable screens of detailed UPS and site power information e LCD interface also supports a number of advanced user setup and operating preferences 1 5 Tripp Lite ERRON 35th Street amp Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Ships with 4 post rackmount installation hardware Optional 2POSTRMKITWM enables 2 post rackmount wallmount installation Optional 2 9USTAND enables tower placement e Built in USB RS 232 and optional SNMPWEBCARD accessory monitoring options HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e Included PowerAlert UPS monitoring software Built in Emergency Power Off EPO interface with cable Specifications General Info RoHS OUTPUT Output Volt Amp Capacity VA 1000 Output kVA Capacity kVA Output Watt Capacity Watts Output kW Capacity kW Power Factor Nominal Output Voltage s 220V 230V 240V Supported Nominal Voltage Details 230v nominal inverter output voltage Frequency Compatibility 50 60 Hz Output Voltage Regulation Line 6 11
7. ule Dimensions hwd cm 8 9 x 44 4 x 34 3 Rack Height U Spaces 34 UPS Power Module Weight Ibs UPS Power Module Weight kg 15 4 UPS Shipping Dimensions hwd in 9 x 24 x 20 2 UPS Shipping Dimensions hwd 22 9 x 61x 51 4 OO O Shipping Weight Ibs Shipping Weight kg 16 3 Cooling Method Fan UPS Housing Material Steel O ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit O to 40 degrees Celsius Storage Temperature Range 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 100 AC Mode Efficiency Rating 100 o 97 Load COMMUNICATIONS LINE BATTERY TRANSFER Low Voltage Transfer to Battery 182 Power Setpoint High Voltage Transfer to Battery 278 Power Setpoint SPECIAL FEATURES 0 to 95 non condensing Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Grounding Lug Back panel grounding lug Cold Start Startup in Battery Mode g During a Power Failure Cold start operation supported High Availability UPS Features Hot swappable batteries Green Energy Saving Features Greater than 95 efficiency GREEN UPS Individually controllable load banks CERTIFICATIONS UPS Certifications CE ROHS Restriction of Hazardous Substances Tested to GOST Russia UPS Certification Details IEC 62040 1 IEC 62040 2 Class A EMI WARRANTY Product Warranty Period 2 year limited warranty I