1. plica EN Instruction on mounting and use JJ ij i EN Instruction on mounting and use Closely follow the instructions set out in this manual All responsibility for any eventual inconveniences damages or fires caused by not complying with the instructions in this manual is declined The hood is conceived for the suction of cooking fumes and steam and is destined only for domestic use The hood can look different to that illustrated in the drawings in this booklet The instructions for use maintenance and installation however remain the same Itis important to conserve this booklet for consultation at any moment In the case of sale cession or move make sure it is together with the product I Read the instructions carefully there is important information about installation use and safety Do not carry out electrical or mechanical variations on the product or on the discharge conduits A Caution WARNING Do not connect the appliance to the mains until the installation is fully complete Before any cleaning or maintenance operation disconnect hood from the mains by removing the plug or disconnecting the mains electrical supply Always wear work gloves for all installation and maintenance operations The appliance is not intended for use by children or persons with impaired physical sensorial or mental faculties or if lacking in experience or knowledge unless they are under supervisio
2. grill Fig 3 Support the panel with your hands while opening it After the opening of the panel you can access the grease filter and after removing it by acting on the handle you can reach the seat of the charcoal filter Fig 4 Place the hood on the set position and secure it with the supplied screws see Figure 5 Place the charcoal filter in its seat as shown in Figure 6 Restore the grease filter removed earlier and close the steel panel To close the panel simply bring it back to the horizontal position until the automatic hooking of the closing takes place Operation Use the high suction speed in cases of concentrated kitchen vapours It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cooking Fig 7 Radio remote control for the remote control of extractor hoods Technical Specifications Power supply alkaline battery 12V mod 23 Working frequency 433 92 MHz Max consumption 25 mA Operating temperature 20 C 55 C Operation To turn on or off the hood press once the button To increase the speed up to the 4th max press button To reduce the speed up to the 2nd press button To return to 1st speed from a higher speed press twice the button To switch off the lights press button To set the timer press button At the first start hold
3. connected through a plug and socket then the plug must be removed from the socket Cleaning The cooker hood should be cleaned regularly at least with the same frequency with which you carry out maintenance of the fat filters internally and externally Clean using the cloth dampened with neutral liquid detergent Do not use abrasive products DO NOT USE ALCOHOL WARNING Failure to carry out the basic cleaning recommendations of the cooker hood and replacement of the filters may cause fire risks Therefore we recommend observing these instructions The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations Grease filter Traps cooking grease particles The grease filter must be cleaned once a month using non aggressive detergents either by hand or in the dishwasher which must be set to a low temperature and a short cycle When washed in a dishwasher the grease filter may discolour slightly but this does not affect its filtering capacity Charcoal filter filter version only It absorbs unpleasant odours caused by cooking The saturation of the charcoal filter occurs after more or less prolonged use depending on the type of cooking and the regularity of cleaning of the grease filter In any case it is necessary to replace the cartridge at least every four mounths The charcoal filter may NOT be washed
4. ew transmission code After changing the transmission code in the radio remote control you need to teach the electronic control unit of the hood the new code as follows press the emergency button visible after opening the stainless steel panel for two consecutive times in order to remove and restore power supply to the product from this moment there are 15 seconds in which to press the light button W so that the hood will synchronize with the new code Disposal of the batteries Ultimate disposal of the batteries should be handled according to all national laws and regulations Do not place used batteries in your regular waste Ultimate disposal of the batteries must be done safely Contact your local waste management officials for other information regarding the environmentally sound collection recycling and disposal of the batteries Operation anomalies The hood does not work Make sure that There is no current blackout e A speed has been effectively selected e The red reset button located above the filters inside the hood is pressed The hood has low efficiency Make sure that e The motor speed selected is sufficient for the quantity of fumes present e The charcoal filter is not worn out 11 Maintenance ATTENTION Before performing any maintenance operation isolate the hood from the electrical supply by switching off at the connector and removing the connector fuse Or if the appliance has been
5. gularly cleaned on both the inside and outside AT LEAST ONCE A MONTH This must be completed in accordance with the maintenance instructions provided in this manual Failure to follow the instructions provided in this user guide regarding the cleaning of the hood and filters will lead to the risk of fires Do not use or leave the hood without the lamp correctly mounted due to the possible risk of electric shocks We will not accept any responsibility for any faults damage or fires caused to the appliance as a result of the non observance of the instructions included in this manual This appliance is marked according to the European directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The symbol mw on the product or on the documents accompanying the product indicates that this appliance may not be treated as household waste Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment Disposal must be carried out in accordance with local environmental regulations for waste disposal For further detailed information regarding the process collection and recycling of this product please contact the appropriate department of your local auth
6. n or have been trained in the use of the appliance by a person responsible for their safety This appliance is designed to be operated by adults children should be monitored to ensure that they do not play with the appliance This appliance is designed to be operated by adults Children should not be allowed to tamper with the controls or play with the appliance Never use the hood without effectively mounted grating The hood must NEVER be used as a support surface unless specifically indicated The premises where the appliance is installed must be sufficiently ventilated when the kitchen hood is used together with other gas combustion devices or other fuels The ducting system for this appliance must not be connected to any existing ventilation system which is being used for any other purpose such as discharging exhaust fumes from appliances burning gas or other fuels The flaming of foods beneath the hood itself is severely prohibited The use of exposed flames is detrimental to the filters and may cause a fire risk and must therefore be avoided in all circumstances Any frying must be done with care in order to make sure that the oil does not overheat and ignite Accessible parts of the hood may became hot when used with cooking appliance With regards to the technical and safety measures to be adopted for fume discharging it is important to closely follow the regulations provided by the local authorities The hood must be re
7. or regenerated Replacing lamps Disconnect the hood from the electricity Warning Prior to touching the light bulbs ensure they are cooled down Replace the old light bulb with the one of the same type as specified in the feature label or near the light lamp on the hood To replace the lamps in the square shaped spotlights press the frame of the spotlight opposite the symbol PUSH then change the bulb and close the spotlight by pressing again on the frame to hook it Replace with a new 12 Volt 20 Watt Maximum halogen light made for a G 4 base SUITABLE FOR USE IN OPEN LUMINAIRES Follow package directions and do not touch new light with bare hands If the lights do not work make sure that the lamps are fitted properly into their housings before you call for technical assistance
8. orities or the local department for household waste or the shop where you purchased this product Additional Installation Specifications Use only the fixing screws supplied with the product for installation Use the correct length screws which are identified in the Installation Guide WARNING Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards Use The hood is conceived for the suction of cooking fumes and steam and is destined only for domestic use The hood has been made for use in the internal recirculating filtering version Cooking fumes and steam are aspirated inside the hood filtered and cleaned passing through the fat filter s and the carbon filter s that MUST be supplied with the hood Installation The minimum distance between the supporting surface for the cooking equipment on the hob and the lowest part of the range hood must be not less than 65cm from electric cookers and 65cm from gas or mixed cookers If the instructions for installation for the gas hob specify a greater distance this must be adhered to ZN Electrical connection The mains power supply must correspond to the rating indicated on the plate situated inside the hood If provided with a plug connect the hood to a socket in compliance with current regulations and positioned in an accessible area after installation If it not fitted with a plug direct mains connection or if the plug i
9. rface for assembling the unit Cover that surface with a protective covering and place all canopy hood parts and hardware in it e In addition check whether near the installation area of the hood in the area accessible also with the hood mounted an electric socket is available and it is possible to connect a fumes discharge device to the outside only suction version e Carry out all the masonry work necessary e g installation of an electric socket and or a hole for the passage of the discharge tube Expansion wall plugs are provided to secure the hood to most types of walls ceilings However a qualified technician must verify suitability of the materials in accordance with the type of wall ceiling The wall ceiling must be strong enough to take the weight of the hood Do not tile grout or silicone this appliance to the wall Surface mounting only Identify on the ceiling a reference point from the exact installation center of the hood see fig 1 and then trace the reference points for the holes to be made in accordance with the dimensions shown in Fig 2 Make the holes in the ceiling using a suitable twist drill bit with 8 mm diameter and insert the supplied plugs Approach the hood to the ceiling and make the electrical connection Open the stainless steel panel placed on the underside of the product where the four lamps are located The opening of the panel is made by pulling on the side corresponding to the air outlet
10. s not located in an accessible area after installation apply a double pole switch in accordance with standards which assures the complete disconnection of the mains under conditions relating to over current category III in accordance with installation instructions Warning Before re connecting the hood circuit to the mains supply and checking the efficient function always check that the mains cable is correctly assembled Warning Power cable replacement must be undertaken by the authorised service assistance centre or similar qualified person Mounting This type of cooker hood must be fixed to the ceiling Very heavy product hood handling and installation must be carried out by at least two persons Before beginning installation e Check that the product purchased is of a suitable size for the chosen installation area e Remove the charcoal filter s if supplied see also relative paragraph This these is are to be mounted only if you want lo use the hood in the filtering version e Check for transport reasons that there is no other supplied material inside the hood e g packets with screws guarantees etc eventually removing them and keeping them e f possible disconnect and move freestanding or slide in range from cabinet opening to provide easier access to rear wall ceiling Otherwise put a thick protective covering over countertop cooktop or range to protect from damage and debris Select a flat su
11. the light button for 5 seconds The far right LED will start flashing every 5 sec the hood stays on for a period of 10min at the selected speed and then it turns off automatically If you increase or reduce the speed while the timer is activated the timer will be disabled 10 Mode of operation If there are two radio remote control systems in the same room or in immediate vicinity having the same transmission code could influence them therefore you need to change the code of one remote control ATT The battery must be replaced every year to ensure the optimal transmitter range To replace the battery remove the plastic cover remove the battery in use and insert a new one respecting the polarity indicated on the container Used batteries should be disposed of in the appropriate containers The product is equipped with a device which automatically switches off after 4 hours of operation since the last performed operation Generating a new transmission code The remote control is supplied from the factory with default codes If you want to generate new codes you must perform the following steps Simultaneously press the UP STOP 0 1 and DOWN continuously for 2 seconds at the same time you will have the LEDs light up then press the UP and DOWN 3 flashes of the LEDs indicate that the operation has been completed ATT This action completely deletes the preexisting default codes Teaching the n
Download Pdf Manuals
Related Search
Related Contents
Hampton Bay IEX1311A-2 Instructions / Assembly Trading Platform User Manual PRS 40 Service Manual Weltron 10m SC/SC Husky FP2205 User's Manual Symmons 553TP-STN Instructions / Assembly USO DELLA PIASTRA USING THE COOKING PLATE Notice Deville DCB 100 C VERSION 3.1 DU 11.06 Copyright © All rights reserved.