Home
        CDA EVPK90
         Contents
1. C  and who will comply with the 1 E E  and  local regulations     The wires in the mains lead of this appliance are coloured in accordance with  the following code     Green  amp  Yellow   Earth  Blue   Neutral  Brown   Live     As the colours of the wires in the mains lead for the appliance may not  correspond withthecoloured markings identifying the terminals connecting DOUBLE POLE SWITCHED  to the fuse spur  proceed as follows  FUSE SPUR OUTLET    The wire which is coloured green and yellow must be connected to the  terminal marked E  Earth  or coloured green    The wire which is coloured blue must be connected to the terminal marked  N  Neutral   or coloured black     The wire which is coloured brown must be connected to the terminal  marked  L  Live   or coloured red     Note  Use a 3A Fuse USE A 3 AMP FUSE    Assembly and electrical connection should be carried out by specialised  personnel     When installing this product we recommend you seek the help of another  individual        Electrical Information  Mains electrical voltage  230   240Vac  50Hz    Total rated power consumption   330W    Troubleshooting  If your extractor is not working   1  Check that the mains supply has not been switched off     2  Check that the fuse in the spur has not blown           Mounting your Extractor   IMPORTANT    The extractor is intended to be mounted directly to the ceiling using  fixings appropriate for the ceiling  Ensure that there is adequate  ceiling strength and supports at t
2. EVPK90 Linear Extractor C D A    Manual for Installation  Use and Maintenance          Important   The manufacturer cannot be held responsible for injuries or losses caused by incorrect  Please note that the manufacturer reserves the right to invalidate the guarantee supplie  installation or misuse of the appliance or use in a commercial environment        This appliance is not designed to be used by people  including children  with reduced pl  who lack experience or knowledge about it  unless they have had supervision or instru  someone who is responsible for their safety     Under no circumstances should any external covers be removed for servicing or mainte  personnel        Appliance information     Please enter the details on the appliance rating plate below for reference  to assist CDA Cu  your appliance and to register your appliance for guarantee purposes                    CE Declarations of Conformity     This appliance has been manufactured to the strictest standards and complies with allapp  Electrical safety  LVD  and Electromagnetic interference compatibility  EMC      IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANC  2002 96 EC     At the end of its working life  the product must be taken to a special local authority was   providing appliance recycling services     Disposing of a household appliance separately avoids possible negative consequences  enables the constituent materials to be recovered  saving both energy and resources  A  hous
3. ST BE CONNECTED TO THE MAINS SUPPLY BY    A COMPETENT PERSON  USING FIXED WIRING VIA A DOUBLE POLE  SWITCHED FUSE SPUR OUTLET AND PROTECTED BY A 3A FUSE   Werecommendthattheapplianceisconnectedbyaqualifiedelectrician  who  is a member of the N I C E I C  and who will comply with the 1 E E  and local  regulations    The wires in the mains lead of this appliance are coloured in accordance with  the following code     Green  amp  Yellow   Earth  Blue   Neutral  Brown   Live     As the colours of the wires in the mains lead for the appliance may not  correspondwith the coloured markingsidentifying the terminals connecting DOUBLE POLE SWITCHED  to the fuse spur  proceed as follows  FUSE SPUR OUTLET  The wire which is coloured green and yellow must be connected to the  terminal marked E  Earth  or coloured green   The wire which is coloured blue must be connected to the terminal marked  N  Neutral   or coloured black   Thewirewhichiscoloured brownmustbeconnectedtotheterminal marked  L  Live   or coloured red     Note  Use a 3A Fuse    USE A 3 AMP FUSE    Assembly and electrical connection should be carried out by specialised  personnel   When installing this product we recommend you seek the help of another  individual     NOTES        NOTES        NOTES           Energ                       Efficiency Information    Attribute    Annual Energy Consumption 134 2 kWh  ime increase factor    Pee  jem    Energy Efficiency Index 96 1  D E           Measured airflow at Best Efficiency Op
4. ation pipe need to be fitted to the motor body bef      To connect the electronic control box  proceed as shown below using screws  G   figs 7     Finally  attach the ventilation pipe  H  to the pipe adaptor  F  and place on the exhaust                  ij    MA       10       Installation  Assembling the extractor ready for mounting        1  Place the extractor body on a table and fix the support sections  D  using  the supplied screws  E  as shown in fig 11 below     2  Remove the screws A  fastening the lower and upper B  support sections  as shown in fig 12 below     3  Measure the height of the ceiling and then the hotplate height from the  floor  The height of the hob assembly  including the body should be  equal to     Ceiling height    H   Hotplate height     Where H  600mm minimum for electric hobs and 700mm minimum for  gas hobs    Note that if the extact height cannot be set  use the support position  corresponding to the next highest one to prevent any issues with installation  heights above hobs              Installation  Assembling the extractor ready for mounting     Zu    LLE    4  Assemble the upper  B  and lower  C  support sections at the desired  height  as calculated in step 3  using the supplied screws  G  as shown in  fig 13     5  When the support sections have been securely fastened together  fit the  upper B  and lower A  chimney sections over the supports  as shown in  fig 14           A            12       Installation  Mounting the extractor to t
5. clean the grease filters  with hot soapy water  You can also wash the grease filters in a dishwasher   ensuring that you place it in an upright position to prevent damage from  other items in the dishwasher  After rinsing and drying  replace the filters   After the grease filters has been replaced  the electronic memory must be  reset by touching key A for approximately five seconds  until the letter A  stops flashing     To remove the grease filters follow the steps below    1  Pull open the handle on the grease filter as shown in fig 2  It will release  at the handle side    2  Then lower the grease filter to remove it completely     To replace the grease filters  repeat the steps in reverse   Please note     Cleaning the grease filter in the dishwasher may lead to discolouration  This  is normal and does not constitute a fault with the appliance        Care and Maintenance   Changing the charcoal filter  re circulating only    When the display flashes alternating the speed selected with the letter F  the  charcoal filters must be replaced  After the charcoal filter has been replaced   the electronic memory must be reset by touching key A for approximately  five seconds  until the letter F stops flashing        To attach a new charcoal filter  first open the cover panels and the filters as  described above  Then offer up the charcoal filter into the frame as shown in  figure 3  Repeat with the other charcoal filter  Then replace the grease filters  and cover panels        T
6. ehold appliances separately  the product is marked with a crossed out wheeled d    Please note       Under no circumstances should the extractor be connected to any gas ventilation s  ducting system       Donot vent the extractor into an attic or loft space       Only house the extractor in rooms with adequate ventilation  Remember that the e  extracted needs to be replaced       Donot tile the extractor in  It should be removable for service or maintenance      Do not use silicone sealant to secure the hood to the wall       You must be able to isolate the extractor from the mains electrical supply after insta     Steam cleaners must not be used when cleaning this appliance       The performance of your extractor will vary depending on a number of factors  Thes  ducting  room volume  ventilation available and cleanliness of the filters     Using your Extractor  For best performance  you should switch on the extractor 15 minutes before starting to co  15 minutes after the end of cooking               Control Panel   A   Light key   B   Decrease speed key  C   Display   D   Increase speed key  E  Timer key                To switch the extractor light on and off    Touch key A     To switch on the extractor     Touch either key B or D  The appliance will switch on at the first speed      To increase the speed touch key D      To switch the extractor off  touch and hold key B for two seconds when the extracto  key B at speed one     The intensive function    The extractor is equ
7. er 347 6 mh  Point   Measured Pressure at Best Efficiency 243 5 pa  Point    Maximum airflow 520 0    mp  lt     O  O o    O        3 o   o  5  3    5 8   lt   a  m 2  o O  2 3  O  5  O   lt     Measured electric power at Best 146 3  2    A  Nominal ighting power    m   gt   Q  D  5  o   lt   D  o  5  eb     lt   lt   Y  gt   D ola  lt   D o     7  oj    y    El Se     oloo  o a 5   xe  ol ae  O ola 3       o3  D 2  oo  o o  O o  8  5 DI  n nla O  E   aca  3 3  c 3     al 313   O O  o G  3 3  O05  O          3 2          mode   ound power level  Lamp efficiency      i Ps 1 0  standby  w 4    O  O     D  o  n  oO  at     D     m  3  o  D      Q   lt        E  amp  O E  All instructions  dimensions and illustrations are provided for gui    right to change specifications without prior notice     CDA    To contact our Customer Care Department  or for Service     please contact us on the details below        
8. he ceiling     1  Using the supplied template  drill four holes in the ceiling and fit suitable  wall plugs into the holes  if required  Note that plugs may not be required  if the extractor is to be mounted directly to the ceiling joists  Ensure that  the wall plugs used are suitable for the intended purpose  See fig 15                2  Fit three screws into the holes  or direct to the joists  leaving at least  3mm standing proud  as shown in fig 16  Note that a screw should not be  fitted in the hole marked X on the diagram                 3  Using the help of another individual  locate the extrac tor on the three  exposed ceiling screws and rotate into position  Tighten the three screws  and then secure the whole assembly in position using a screw in hole X   The extractor should be free standing at this point  See fig 17 below              Installation  Mounting the extractor to the ceiling     4  Recirculating mode   If the extractor is to be used as a recirculation device  filtering the air  before recycling into the kitchen then the vent diverter needs to be fitted   Fit the diverter M  to the upper support section using screw  I  and  connect the ventilation pipe  H      5  Connect the mains electrical supply  Refer to the    Mains electricity  connection    section of the manual  and then secure the chimney  sections B  to the upper support using the four supplied screws  F   as  shown in Fig 19 above     14       Mains Electricity Connection       THIS APPLIANCE MU
9. he fixing points  if in doubt   consult a joiner or electrician     When the extractor is to be installed above an electric hob  the minimum  distance between the hob and extractor must exceed 600mm  650mm is  recommended            When the extractor is to be installed above a gas hob  the minimum  distance between the hob and extractor must exceed 700mm  750mm is    recommended    Gas  750mm recommended     If the instructions provided with your gas hob state that the required Electric  650mm recommended     distance between the hob and extractor must be greater than 700mm   then that is the distance that should be observed  this is a legal requirement  and may lead to your hob being disconnected from the gas supply and the  installation being reported to RIDDOR  The height should be measured  from the top of the burners         IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE  GAS HOB  THE MINIMUM DISTANCE BETWEEN THE HOB AND  EXTRACTOR MUST BE AT LEAST 760mm     The width of any hob must not be greater than the width of the extractor  installed above it  Fig  5    Ducting and Ventilation   We recommend the use of ducting with a diameter of 150mm  Ducting  with diameters of 100mm or 120mm may be used  but performance will be  reduced                                                        Installation  Note   We recommend that you seek the help of another individual when installing this produ                 Preparing the extractor  The electronic control box and ventil
10. ipped with an intensive function which runs for ten minutes befi  speed  To activate the intensive function  touch key D at speed three  The display will b    The timer    The extractor is equipped with a timer that allows the extractor to run for 15 minute    To activate the timer  touch key E  The display will flash a decimal point when the ti    Please note  The timer cannot be activated when the intensive function is on     The clean air function    The extractor is equipped with a clean air function that switches on the motor for te    To activate the clean air function  touch key E for two seconds when the appliance is o  either key B or D  To switch off the clean air function  touch key E  The display C will  running  and will show the letter C during the fifty minutes when the motor is not r    Care and Maintenance   IMPORTANT   DO NOT PERFORM MAINTENANCE OR CLEANING  OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE  ELECTRICITY SUPPLY        Cleaning  You should use a nonabrasive cleaner  Any abrasive cleaner  including Cif   will scratch the surface and could erase the control panel markings        You can clean your extractor effectively by simply using a dilute solution of  water and mild detergent and drying to a shine with a clean cloth     Cleaning the grease filter  The grease filters should be kept clean to minimise the risk of fire     When the display flashes alternating the speed selected with the letter A   or at least once a month  you should remove and 
11. o attach a new charcoal filter  first remove the grease filters as described  above  Then offer up the charcoal filter to the side of the motor as shown in  figure 3 and turn it clockwise until it locks into place  Repeat with the other  charcoal filter on the other side of the motor  Then replace the grease filters  and cover panels        Changing the Light  DO NOT CHANGE THE LIGHT BULB IMMEDIATELY AFTER USE AS  THE BULB WILL BE HOT  ALLOW IT TO COOL BEFORE REMOVING IT        Using a flat blade screwdriver  carefully prise off the lamp cover as shown in  figure 4  Remove the bulb and replace with a 12V 20W halogen light bulb   Finally  replace the light bulb cover        Do not touch bulbs or adjacent areas during or straight after prolonged use  of the lights        The light is designed for use during cooking and not for general room illumi   nation  Extended use of the light can reduce the life span of the bulb     Bulb replacement is not covered by the guarantee     Only use bulbs recommended for your extractor  Do not fit bulbs of a higher  power rating     Bulbs of a lower power rating may be adequate for use  generally last longer  and use less energy        Mains Electricity Connection       THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY  A COMPETENT PERSON  USING FIXED WIRING VIA A DOUBLE POLE  SWITCHED FUSE SPUR OUTLET AND PROTECTED BY A 3A FUSE     We recommend that the appliance is connected by a qualified electrician   who is a member of the N l C E l 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
図書館だより - 帝京科学大学  Atex RW WD EH  Lightolier ProSpec IS:26600 User's Manual  Mode d`emploi détecteur de présence PD2 Max KNX (V5.0)    Preguntas frecuentes  Philips GC1029  Roland TD-15 User's Manual  Philips Sonicare For Kids Compact sonic toothbrush heads HX6032  取扱説明書 - レッツコーポレーション    Copyright © All rights reserved. 