Home

LevelOne IES-1880

image

Contents

1. e For use in Pollution Degree 2 Environment e Supports Din Rail or Panel Mounting installation e Suitable for use in Class Division 2 Groups A B C and D hazardous locations or non hazardous locations only e Sealed Relay Device information Sealed Device Relay Type V23079 A2008 B301 manufactured by Tyco Electronics Logistics Ag o Relay Cover Manufacture of Plastic Material Ticona Designation of Plastic Material Vectra A130 o Relay Epoxy Manufacture of Material Guangzhou Wells Chemical Co Ltd Designation of Material Type 6060RP Generic Name of Plastic Material Epoxy Resin Package Contents ES 1880 a Quick Installation Guide CD User Manual IES 1880 Page 2 Overview LevelOne IES 1880 Industry Ethernet Switch provides 16 ports of 10 100Base TX plus 2 ports of 1000Base Gigabit Ethernet to enable high speed network at mission critical environment This device is designed to be mounted on an industry standard DIN rail plus the clearly visible status LEDs provide simple monitoring of port link activity High Reliability All components are built to withstand harsh environment applications without compromise where humidity temperature variation and even shock vibration are concerns including Electric amp Utility Critical Infrastructure Transportation and Surveillance Security This device operates under 40 to 75 Celsius 40 to 167 Fahrenheit temperature Resilient Ring Network S
2. 0O Infinity IES 1880 16 FE 2 GE Managed Switch 40 to 75C DIN rail Quick Installation Guide Default Setting v1 00 1206 Features e Meets NEMA TS1 TS2 Environmental requirements such as temperature shock and vibration for traffic control equipment e Meets EN61000 6 2 amp EN61000 6 4 EMC Generic Standard Immunity for industrial environment e Manageable via SNMP Web based Telnet and RS 232 console port e Supports Command Line Interface in RS 232 console e Support 802 3 802 3u 802 3ab 802 3z 802 3x Auto negotiation 10 100 1000Mbps full half duplex Auto MDI MDIX e 100Base FX Multi Single mode SC or ST type 100Base BX WDM Single mode SC type e 1000Base SX LX Multi mode or Single mode SC type 1000Base BX WDM Single mode SC type e Support 8192 MAC addresses Provides 2M bits memory buffer e Alarms for power and port link failure by relay output e Power Supply Redundant DC Terminal Block power inputs or 12VDC DC JACK with 100 240VAC external power supply e Field Wiring Terminal Use Copper Conductors Only 60 75 C 12 24 AWG torque value 7 b in e Operating voltage and Max current consumption 1 25A 12VDC 0 625A 24VDC 0 313A 48VDC Power consumption 15W Max e 40 C to 75 C 40 F to 167 F operating temperature range Tested for functional operation 40 C to 85 C 40 F to 185 F UL508 Industrial Control Equipment certified Maximum Surrounding Air Temperature 75 C 167 F
3. d Exec Mode or Enable Mode And the switch_a prompt will show on the screen 10 Logon to Configure Mode Configure Terminal Mode 11 Atthe switch_a prompt just type in configure terminal and press lt Enter gt to logon to Configure Mode or Configure IES 1880 Page 5 Web Configuration 1 Login the switch 2 Specify the default IP address 192 168 1 10 of the switch in the web browser A login window will be shown as below Login Windows Internet Explorar 3 Enter the factory default login ID root 4 Enter the factory default password no password 5 Then click on the Login button to log on to the switch Adcress hp 7192 108 1 10 cgi b n swibch cgi Ed Go Lrks io olodo MarH Bril Swil gt Guar z JL 3l Syren information J Ar Syste aarre owt a JE Sw hiag Firnvzarc versien 1 50 3 QPOZUY CY 23 22 5 Tr nki g tystem time Itu Jan 1 30 00 30 UCL 19C G STP Fire MAC acied ess CO BAN TAR G wl sk Teali gale way Foue D ns DNS Server Kone G N P 5 2 x YLAN IL TP Address IE Saknet Mack 5 athe Protocas 1 192 162 1 20 255 255 255 0 Inter ct Note Please refer to User Manual for more detailed information IES 1880 Page 7
4. ommands one per line End with CNTL Z switch_a config tinterface vlanl switch_alconfig if Hip address 192 168 1 10 24 switch_a config if Connected 0 01 52 WT100 115200 8 N 1 IES 1880 Page 6 Console Configuration 1 Connect to the switch console 2 Connect the DB9 straight cable to the RS 232 serial port of the device and the RS 232 serial port of the terminal or computer running the terminal emulation application Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal emulation program such as HyperTerminal to the switch console port Configuration settings of the terminal emulation program 4 Baud rate 115 200bps Data bits 8 Parity none Stop bit 1 Flow control none 5 Press the Enter key The Command Line Interface CLI screen should appear as below 6 Logon to Exec Mode View Mode 7 At the switch_a login prompt just type in root and press lt Enter gt to logon to Exec Mode or View Mode And the switch_a gt prompt will show on the screen UJ 115200 HyperTerminal Elle Endit Wiw Call Transier Help D 3 0a F swilch_a login rool Switch version 1 30 r235 sdkr59 07 08 08 15 24 33 switch_a gt _ Connected 0 00 25 TIUUJ 8 Logon to Privileged Exec Mode Enable Mode 9 At the switch_a gt prompt just type in enable and press lt Enter gt to logon to Privilege
5. s known to be free of ignitable concentrations e WARNING EXPLOSION HAZARD Substitution of any component may impair suitability for Class l Division 2 e WARNING Exposure to some chemicals may degrade the sealing properties of materials used in the Sealed Relay Device e RECOMMENDATION Itis recommended to inspect the sealed relay device periodically and to check for any degradation of the materials and to replace the complete product not the sealed device if any degradation is found IES 1880 Page 4 Terminal Mode And the switch_a config prompt will show on the screen 12 Set new IP address and subnet mask for Switch 13 Atthe switch_a config prompt just type in interface vlan1 1 and press lt Enter gt to logon to vlan 1 vlan1 1 means vlan 1 And the switch_a config if prompt will show on the screen 14 Command Syntax ip address A B C D M A B C D specifies IP address M specifies IP subnet mask M 8 255 0 0 0 16 255 255 0 0 or 24 255 255 255 0 15 For example At the switch_a config if prompt just type in ip address 192 168 1 10 24 and press lt Enter gt to set new IP address 192 168 1 10 and new IP subnet mask 255 255 255 0 for Switch 115200 Hyperterminal Elle Edit wiew Call Transfer Help De 086 gf switch_a login root Switch version 1 43 1 61 22 09 15 40 59 switch_aenable switch_aticonfigure terminal f Enter configuration c
6. upports Ring topology network providing simple installation and ultra fast network recovery performance less than 15ms Unlike much complex resilient topology such as a redundant star the Ring simplifies the network design and requires less cabling installation In addition fast network recovery time helps minimize system downtime Oil amp Gas Hazardous Application Comply with Class 1 Division 2 certified UL 1604 standard UL ISA12 12 01 is a higher level certification to assure that products can be safely operated where specific potentially flammable or explosive materials may be present IES 1880 Page 1 LED Status o yi w a Ce ee etn PW 1 2 3 10 100Base TX 100Base FX Network connection is established LNK ACT Flashing Transmitting or Receiving data Connection speed at 100Mbps 10 100 Connection speed at 10Mbps 10 100 1000Base TX Green 1000Base SX LX Orange Network connection is established LNK ACT Flashing Transmitting or Receiving data IES 1880 Page 3 Power Input 115200 8 n 1 oo jo oo 0 of Poa a 12 to 48VDC Powerl 12 to 48VDC Power2 Relay Output 1A 24VDC The contact closes if Power1 or Power2 are both failed The relay contact closes if Power3 is failed but both Power1 and Power2 are On Power3 DC Jack type with 12VDC Input Terminal Block e WARNING EXPLOSION HAZARD Do not disconnect equipment while the circuitis live or unless the area i

Download Pdf Manuals

image

Related Search

Related Contents

Manuale utente Power HT  SUPPLEMENTAL RESTRAINT SYSTEM (SRS)  Onkyo DV-BD507 User's Manual  Philips FQ003/20/60  EXTERIOR & INTERIOR  Samsung NP350V4X User Manual (FreeDos)  Instructions: Folding Travel Bed Mode d`emploi: Pliable lit de voyage  GTC 230/18  Canon C350iF Getting Started Guide  

Copyright © All rights reserved.
Failed to retrieve file