Home
Da-Lite Tensioned Dual Masking Electrol
Contents
1. INSTRUCTION BOOK FOR tensioned Dual Masking Electro DA LITE Important Safety Instructions When using your video equipment basic safety precautions should always be followed including the following 1 Read and understand all instructions before using 2 Position the cord so that it will not be tripped over pulled or contact hot surfaces 3 If an extension cord is necessary a cord with a current rating at least equal to that of the appliance should be used Cords rated for less amperage than the appliance may overheat 4 To reduce the risk of electric shock do not disassemble this appliance Contact an authorized service dealer when repair work is required Incorrect reassembly can cause electric Shock when the appliance is used subsequently 5 The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire electric Shock or injury to persons Save These Instructions 1 Pre Installation Carefully unpack screen and remove outer wrapping from case 2 Make sure to recheck measurements of screen Drywall Screw location before installation Access Panel Machine Screw Phillips Head Screw Shipping Bracket Hex Head Screw Figure 1 Installation 1 Install screen by raising unit into position between joists at one end only Install one lag screw in each mounting bracket 2 Level unit lengthwise with a carpenter s level and plumb level Secure opposite
2. warranty does not apply to equipment showing evidence of misuse abuse or accidental damage or which has been tampered with or repaired by a person other than authorized Da Lite personnel Da Lite s sole obligation under this warranty shall be to repair or to replace at Da Lite s option the defective part of the merchandise Returns for service should be made to your Da Lite dealer If it is necessary for the dealer to return the screen or part to Da Lite transportation expenses to and from Da Lite are payable by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the one 1 year warranty period This warranty gives you specific legal rights and you may also Nave other rights which vary from state to state TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FROM INTERRUPTION IN OPERATION OF EQUIPMENT OR FOR INCIDENTAL DIRECT OR CONSEQUENTIAL DAMAGES OF ANY NATURE In the event that there is a defect in materials or workmanship of a Da Lite product you
3. ds securing mask surface to case Use supplied 1 8 nex key and a 5 16 wrench to remove silver Shipping brackets attached to slat and screen case Test installation by carefully running picture and mask surfaces up and down several times Be prepared to stop screen Standard Duty Cycle 1 MIN ON 3 MIN OFF NOTE When rolled down the picture surface should wrap fully around the roller No part of the roller should be exposed Picture and mask surfaces will automatically stop in the down position The mask will start down off the front of the roller travel completely down past the bottom of the viewing surface then step back against the viewing surface to eliminate shadowing by rolling up the back side of the roller Do not adjust the limits to change this feature Run the picture and mask surfaces upward When the picture and mask surfaces are fully up the limit switches in the motors are tripped and the motors shut off Check for satisfactory condition by operating screen a few times Reinstall access panel Screen Adjustment CAUTION The mask should not be field adjusted for more or less drop A ATTENTION Le masque ne doit pas tre ajust sur place pour r gler la chute A CAUTION Contact Da Lite at 800 622 3737 or 574 267 8101 if screen motor needs adjustment A ATTENTION Contactez Da Lite au 800 622 3737 ou au 574 267 8101 au cas le moteur de l cran a besoin d tre ajust 15V Dual Motor Co
4. end CAUTION Do not seal in until screen has been secured in position and properly tested for satisfactory operation A ATTENTION Ne fixez pas l cran jusqu ce qu il ait t correctement mis en place et qu il fonctionne convenablement Carefully remove three shipping brackets by removing six hex head screws from case and three phillios head screws from aluminum slat Use a phillios screwdriver a hex socket and a ratchet Slat should move freely Fig 1 Detach access panel by removing screws Fig 1 Remove junction box cover plate Install electric hook up that applies to your unit Make sure to review your electrical installation checklist and wiring diagram included for either 120 volt switch 220 240 volt switch or low voltage control NOTE Must be installed in accordance with the requirements of the Local Building Codes the Canadian Electrical Code CEC CAN CSA C221 and the National Electric Code NEC NFPA 70 3 Remove center support brackets on 8 and wider screens only Screen Motor reverse brackets and reinstall flush with the top of the box Mask Motor Mask Surface a as u F Do LLLP L LE SL LLL GDI LL LG Picture Surface Figure 2 CAUTION Do not cut tape on fabric with a knife or any sharp tool Remove by hand A ATTENTION Ne coupez pas le ruban adh sif sur la toile avec un couteau ou un outil tranchant Retirez ala main Carefully remove two wood boar
5. may contact our Sales Partners at PO Box 137 Warsaw IN 46581 0137 574 267 8101 800 622 3737 IMPORTANT THIS WARRANTY SHALL NOT BE VALID AND DA LITE BRANDED PRODUCTS SHALL NOT BE BOUND BY THIS WARRANTY IF THE PRODUCT IS NOT OPERATED IN ACCORDANCE WITH THE DA LITE WRITTEN INSTRUCTIONS Keep your sales receipt to prove the date of purchase and your original ownership A Milestone AV Technologies Brand 3100 North Detroit Street Warsaw Indiana 46582 P 574 267 8101 or 800 622 3737 F 5742677804 or 8773254832 E info da lite com www da lite com DL 0271 Rev 2 10 14 O 2014 Milestone AV Technologies LLC Printed in U S A 79338
6. nished Ceiling Picture Surface Masking Surface 6 X 1 Steel Bar In Pocket Aluminum Slat Offset mounting recessed above ceiling May be adapted for 1 4 paneling for ceiling Tensioned Dual Masking Electrol Instructions Case Length Screen Fabric Width 15 34 All Sizes 1 FN Mounting Bracket a Motor End Electrical Outlet 7 METHOD D Suggested A MS Wine HUM PGR Mounting KS Joist Suspended S Ceiling Tile A N 8 1546 Picture Surface Masking Surface Ye X 1 Steel Bar In Pocket T Bar Furnished Panel With Ceiling Aluminum Slat Flush mounting recessed above ceiling For use with dropped ceiling May also be adapted for use with acoustical or other ceiling 3 4 thick but cut to 1 4 thick under screen case and panel 8 And Wider Screens Only Troubleshooting Visit www da lite com to find installation and troubleshooting tutorials You will also find a link to Live Chat for interactive support and you can contact us by email at info da lite com or by phone at 800 622 3737 or 574 267 8101 with any troubleshooting questions Symptom Cause Incorrect line voltage Blown fuse Tripped circuit breaker No power to operating switch or junction Screen will not operate Motor does not hum Power at junction box Thermal overload tripped Broken wire in the dowr or up position Defective motor limit switch or capacit
7. ntrol Up Black Ground Green E 4 Wire Mask Motor Mask Motor Up Black Ground Green 4 Wire A Screen Motor Screen Motor MOV A C 60 Cycle Black Hot White Common Ground Wire 220V Dual Motor Control Up Brown Up Brown Common Blue Common Blue T T D 4 Wire eee 4 Wire Mask Motor Screen Motor Mask Motor Screen Motor 220V AC 60 Cycle Brown Hot Blue Common Ground Wire Suggested Methods Of Installation METHOD A Mounting Bracket Suggested Ya Lag Screws a Finished gt Ceiling Can Be Painted Same As Ceiling or Removed And Replaced With Finished Ceiling le 37 Panel Picture Surface Masking Surface Ys x 1 Steel Bar In Pocket Aluminum Slat Offset mounting recessed above ceiling For plaster dry wall tile or paneling Bottom of case painted same finish as ceiling METHOD B Mounting Bracket Suggested 4 Lag Screws ES Mounting Joist 7 Finished pia Cad Ceiling as Y lt Picture Surface Ceiling Tile Cut To 14 Thick Masking Surface Attach With Mastic e 346 x 1 Steel Bar In Pocket Aluminum Slat Offset mounting recessed above ceiling May be adapted for 3 4 ceiling but cut to 1 4 thick under screen case and panel NOTE Must mark hole location of screws in 3 1 2 panel for removal if covering with tile METHOD C Mounting Bracket Suggested 4 Lag Screws 8 As SNPFurring Fi
8. or Capacitor burned out Incorrect stopping position in Dowr limit switch out of adjustment downward direction Incorrect stopping position in a i Up limit switch out of adjustment upward direction Noise NOTE Screen will operate Gear Noise with a low pitched hum Solution Verify 115125V or 220 240V If insufficient voltage rewire incoming electric line Replace fuse Reset circuit breaker Check above Tighten all loose wire connections Correct any improper connections Down Position Check for power across black and White leads Up Position Check for power across red and white leads Let motor cool down for 15 minutes Try again Check for continuity Cut off old splice and reconnect Replace motor assembly NOTE Motor is a sealed assembly Replace motor assembly See installation instructions Adjust up limit switch See installation instructions Replace motor assembly Replace motor assembly LIMITED ONE YEAR WARRANTY ON DA LITE PRESENTATION PRODUCTS Milestone AV Technologies LLC warrants certain Da Lite branded products to the original purchaser only to be free from defects in materials and workmanship for a period of one 1 year from the date of purchase by the original purchaser provided they are properly operated according to Da Lite s instructions and are not damaged due to improper handling or treatment after shipment from the factory This
Download Pdf Manuals
Related Search
Related Contents
Texas Instruments Laptop 1 User's Manual König KN-STUD70/LAMP halogen lamp CP FIVE 1.2 気体採取方法(pdf版) S8372CR4 corega Fast SW1002/1802 取扱説明書 Radiographie 786 - Patterson Dental/Dentaire Visualizar/Abrir - Universidade Federal de Pernambuco Acer Extensa 4100 User's Manual Sunny Island 3324/4248 Guide d`installation Copyright © All rights reserved.
Failed to retrieve file