1. Software TecnoManager downloadable free of charge from www tecnoware com Telephone and Modem protection RJ11 RJ45 plugs included Output sockets 4 UPS Output sockets IEC type 2 ONLY FILTERED Output sockets IEC type Dimension W x H x D 13 x 18 2 x 32 cm Net Weight 7 8 Kg 8 6 Kg 10 4 Kg Technical data may change without prior notice Connect the printers to the ONLY FILTERED Output sockets UPS ERA LED 1 5 2 0 2 6 11 User s manual 9 Maintenance 9 1 UPS Cleaning Before starting any cleaning operation be sure that 1 The AC Input Voltage for the UPS has been removed 2 The UPS is OFF Use only a cloth dampened with water to clean the unit If UPS works in an environmental unusually dusty or dirty remove the dirty from the ventilation holes Before restarting the UPS be sure it is completely dry If any liquid gets inside the UPS do not start the unit and contact Technical Service immediately 9 2 Battery If the UPS is NOT going to be used for a long period of time ensure that the batteries are left fully charged If the UPS has not been used for more than three months go through the First Start Up procedure described in the chapter 5 before using it again Please keep in mind that the batteries must be recharged at least once a month Take in mind that batteries are recharged automatically if the UPS works in Normal mode or if the UPS is o
2. 2 Personal Computers with 550W PSU 450W real power 2 LCD Monitors 80W 2 Printers 170W 2 Personal Computers with 650W PSU 550W real power 2 LCD Monitors 80W 2 Printers 280W Technology Line Interactive with Stabilizer Nominal Input Voltage Single phase 230 Vac Input Voltage Range 20 25 Input Output Frequency 50 60 Hz automatic selection Input Frequency Range 5 Nominal Output Voltage Single phase 230 Vac Output Voltage Regulation Normal mode Through AVR Automatic Voltage Regulation Output Voltage Regulation Battery mode 5 Output Inverter Waveform Modified Sinewave Accepted Overload lt 130 Certifications CE Standards CEl EN 62040 1 2009 Low Voltage Directive CEI EN 62040 2 2006 EMC Directive Efficiency 92 Battery Type Lead acid sealed free maintenance Number of batteries 2 Nominal Battery Voltage 24 Vdc Battery Specifications 12 Vdc 7 2 Ah 6 cells 12 Vdc 9 Ah 6 cells Backup Time typical 10 min 8 min Battery Charge Time typical 4 hours Hot Swap Battery Included Audible Noise at 1 meter lt 45 dBA Cooling Natural Fan cooling Environmental Operative Specification Temperature 0 40 C Humidity 0 95 without condensation Altitude max 3 000 mt Computer Interface 1 USB port UPS Management Software
3. is back within range the UPS switches automatically to the Normal mode Make sure that the UPS never indicates Overload condition Do not connect a load greater than rated value to the UPS see POWER specifications in the chapter Technical Characteristics as this may damage the unit In this case the warranty is void 6 5 Fault Condition The UPS indicates the Fault condition by LCD display by lighting of the Fault led and by emitting a continuous acoustic alarm During Fault condition the UPS doesn t supply Output power and so all the supplied devices are switched off 7 Communication Interfaces The UPS is factory equipped with USB Communication Interface On the UPS rear side there is the connector of the Interface To activate USB communication it is sufficient to connect the USB cable only The USB signal is isolated through photo couplers from the dangerous voltages that are present inside the UPS Connecting to the Web site www tecnoware com it is possible to download free of charge the update UPS management Software TecnoManager compatible with the most popular Operative Systems User s manual 10 UPS ERA LED 1 5 2 0 2 6 8 Technical Characteristics UPS ERA LED Model 1 5 2 0 2 6 Power 1500 VA 1050 W 2000 VA 1400 W 2600 VA 1820 W Recommended for 1 Personal Computer with 650W PSU 550W real power 1 LCD Monitor 80W 1 Printer 420W
4. or a LAN TNV 3 type connections 6 Computer Interface USB connector it is the communication USB port The 2 ONLY FILTERED Output receptacles red colour 4 protect only the devices connected from overvoltages and disturbances of the AC line Please connect ONLY the NON critical devices to the ONLY FILTERED Output receptacles In case of anomaly to the AC line black out ONLY the UPS Output receptacles black colour 3 continue supplying the correct power to all connected equipment Please connect all the non critical devices to the UPS Output receptacles UPS ERA LED 1 5 2 0 2 6 7 User s manual Electrical Installation and First Start Up We advise you to follow the steps below explained for greater safety 1 Switch off all the devices Personal Computer or other electronic devices that need to be supplied by the UPS 2 Connect the UPS Input socket to the AC line outlet Through the Personal Computer supplying cable It is mandatory to ground the AC line outlet according to the Safety Standards Carefully check the grounding make sure that the utility power is available and that its range falls within the UPS specifications refer to the Specifications chapter 3 Press the ON OFF button on the front panel the UPS emits a brief acoustic signal turns on the Leds and performs a functioning SELF TEST After some seconds the UPS starts to work in Normal mode the Line Led in blue color is on Leav
5. rings or other metal objects b Use tools with insulated handles c Wear rubber gloves and boots d Do not lay tools or metal parts on top of batteries IN e Disconnect the charging source prior to connecting or disconnecting battery u terminals f Determine if battery is inadvertently grounded If inadvertently grounded remove source from ground CAUTION Do not dispose of batteries in a fire The batteries may explode CAUTION Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes It may be toxic 9 4 Operator Safety Whenever the UPS is not responding anymore to original characteristics the UPS must be made non operative and every usage not authorised must be avoided After it will be necessary to refer to qualified technical personnel Original safety characteristics might not be if for example the UPS has visible damage or irregular operation UPS ERA LED 1 5 2 0 2 6 13 User s manual 10 Troubleshooting Alarms and problems you may encounter during operating the UPS are given in the table below Apply the suggestions corresponding to each anomaly as described into the table If your anomaly is excluded or the suggested actions do not solve your problem consult the Technical Service Please give the following information to the Technical Service Model and serial number of the UPS which can be found on the nameplate on the bottom side of the UPS Desc
6. s manual 4 UPS ERA LED 1 5 2 0 2 6 4 EXTERNAL DESCRIPTION 4 1 Front Panel The front panel informs the user about operating status alarm conditions and measurements Front panel shown below consists of two parts 1 3 Leds that show the functioning modes alarm and fault conditions 2 ON OFF button enables the user to turn ON OFF the UPS A TECNOWARE Figure 1 Front panel UPS ERA LED 1 5 2 0 2 6 5 User s manual 4 1 1 Leds and ON OFF Button Please refer to figure 2 321 4 Figure 2 LCD Display 1 Line LED this blue led is always on in LINE mode 2 Battery LED this yellow led is on in BATTERY mode 3 Fault LED this FAULT led red switches on to indicate the excessive or the OVERLOAD condition or generic FAULT 4 ON OFF Button to turn ON and OFF the UPS User s manual 6 UPS ERA LED 1 5 2 0 2 6 4 2 Rear Side 4 4 UPS ERA LED 1 5 2 0 UPS ERA LED 2 6 Figure 2 Rear Side 1 Grounded AC Input power socket IEC C14 type to connect the UPS to the AC utility line Input fuse electrical specification max current 10 A ERA LED 1 5 2 0 2 6 voltage 250 V Grounded UPS Output receptacles IEC C13 type black colour to supply critical loads Grounded ONLY FILTERED Output receptacles IEC C13 type red colour to supply NON critical loads 0 kh WwW N Telephone protection RJ11 RJ45 IN OUT connectors to protect and filter a phone line an ADSL
7. Battery Led in yellow color and by an acoustic signal every 10 seconds 6 3 Low Battery and Automatic Restart In Battery mode ERA LED indicates the Low Battery condition whenever the battery reaches a charge level allowing connected devices to operate for approximately one more minute The UPS warns operators of Low Battery by lighting of Line and Battery Leds and by emitting an acoustic signal every second If AC Input does not come back on within few minutes the UPS shuts down automatically thus preventing the batteries from discharging excessively the UPS stops supplying Output power deactivates control panel indication and goes to a waiting state Once AC Input comes back on the UPS restarts automatically and after some seconds it goes back to work in Normal mode After a complete discharge the UPS needs 4 hours to recharge completely the batteries The UPS recharges batteries automatically if it works in Normal mode or if it is off and connected to the AC Input Line UPS ERA LED 1 5 2 0 2 6 9 User s manual 6 4 Load Control When the Output load is higher than nominal value the UPS warns of Overload condition by emitting a continuous acoustic alarm The UPS warns of an Overload less than 110 by acoustic alarm An Overload between 110 and 130 is accepted for about 30 seconds and after UPS switches automatically off The UPS switches immediately off if the Overload is higher than than 130 Once the requested power
8. TECNOWARE Uninterruptible Power Supply ERA LED 1 5 ERA LED 2 0 ERA LED 2 6 User s manual Index Safety Warnings ies 2 1 Introduction i 3 2 General Characteristics ooooocooccoorocnroccrnnccnncocorocccncconoroccrocconoconoso 4 3 Receipt and site selectioN ooooooocccnroccronconncoconocccnnccnorocanocconoconoso 4 4 EXTERNAL DESCRIPTION c css ccccccsseccntccssecccecstecetsvetectteceteceteesteosssonsscese 5 4 1 _ Front Panel rare Haase tele 5 4 1 1 Leds and ON OFF Button ce ccc eece nce e eee e eee eee eeceeeceeeeeseeeeeseeeeees 6 4 2 Rear Side aus ae endeten ieee eh ceeded ae are a 7 Electrical Installation and First Start Up cccccccscccsscccsscccesscesssceees 8 FUR CCTONING oie crete ree iaa 9 6 1 lt NOrmal MOde iii nn A E 9 6 2 Battery Moderan 2 A ee ee 9 6 3 Low Battery and Automatic Restart ooooccocococcronnncccncarononanoncarono os 9 6 4 Load Control eu nn nee nennen denen 10 6 5 _Fault Condition unseren bag 10 Communication Interfaces ooocooccoccconccnncoccnoncconccnoconoroccconccnoconoso 10 TechnicaliCharacteristics nu ed 11 Maintenance schnellst 12 9 1 UPS Cleaning esse ies Led re aes Savi eee hae Sheds 12 932 ROO 12 9 3 Battery Replacement erssssssesnnsnnnnennnnnnnnnnennnnnnnnnnnnssnnnnennennnn 12 9 47 Operator Safety ars rn cda 13 10 T ro bleshooting 2 423 20 200 R00 0 ce stececa es cctecettcatecass heran e
9. TY instructions for the operator for the UPS correct installation and gives useful advice on the product and battery maintenance For any type of problem please refer to this manual before calling the customer service ERA LED is constantly being developed and improved consequently your unit may differ somewhat from the description contained in this manual This manual includes the following models e ERALED 1 5 1 5 KVA e ERA LED 2 0 2 0 KVA e ERA LED 2 6 2 6 KVA In this manual ERA LED will simply be referred to as UPS UPS ERA LED 1 5 2 0 2 6 3 User s manual 2 General Characteristics ERA LED has all the advanced features which guarantee maximum reliability and safety All functions are controlled by a microprocessor giving full guarantee of high reliability Output Voltage regulation through AVR Automatic Voltage Regulation Overload protection both in normal mode and in battery mode High performance battery charger which extends the battery medium life ensuring an optimal recharge Start up even if the electrical network is not available Automatic restart after an automatic shut down due to a low battery condition once the AC utility power returns Adapts automatically to 50 or 60 Hz input frequency 3 Leds to show the functioning modes alarm and fault conditions Acoustic signals of various kinds indicating functioning modes and alarm fault condition Communication with t
10. are user serviceable Any repair or maintenance work must be performed exclusively by qualified technical personnel authorized by TECNOWARE TECNOWARE declines any responsibility if this warning is disregarded Warning to the technical personnel authorized for Service since internal components are connected to the batteries they will remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing the positive cable red colour from the positive pole of the battery It is compulsory to ground the UPS according to Safety Standards The AC mains power supply socket used to power the UPS must have an earth connection In the event of AC main power supply failure when the UPS works in Battery mode do not unplug the power supply cable to the UPS to ensure earth continuity to the connected loads Since the AC mains power supply cable acts as a separation device the AC mains power socket used to supply the UPS and or the rear side of the UPS must be accessible to easily disconnect the cable in case of dangerous conditions Risk of electric shock at the Output lines when the UPS is ON Risk of electric shock at the Output lines while the unit is connected to the AC utility line Do not obstruct ventilation slots or holes and do not rest any object on top of the UPS Do not insert objects or pour liquids in the ventilation holes Ins
11. e the UPS in Normal mode for at least 4 hours in order to completely recharge the batteries 4 Switch the UPS off by pressing again the ON OFF button 5 Connect the devices to be supplied to the UPS outputs by using only the included cables Be sure all the devices have the main switch in ON position 6 Turn on the UPS again Check that it starts working correctly and it doesn t signal any sort of anomaly Moreover be sure that all the devices connected to the UPS outputs are working correctly Check that the UPS do not go in overload status otherwise it is necessary to remove part of the Output load 7 Simulate a black out by removing the AC Input line The UPS starts working in Battery mode the Line Led blue color is off and the Battery Led yellow color icon is on Moreover the UPS emits a brief acoustic signal every 10 seconds 8 Be sure that all the devices connected to the UPS outputs are working correctly and the UPS doesn t signal any sort of anomaly 9 Restore the AC Input line after few seconds the UPS turns back in Normal mode Before using ERA LED normally leave it in Normal mode in order to charge the batteries completely as specified at point 3 The batteries reach the 90 of their capacity after about 4 hours of recharge It is compulsory to ground earth the UPS according to the Safety Standards Risk of electric shock at the Output lines if the UPS is ON even when the UPS is not connected to AC u
12. en 14 Conformity to the European Directives cceecescccsccescceccesccesscescesceess 15 Product Disposicion lest 15 Lead Batteries ierre ek Ks Re rica 15 Copyright 2014 TECNOWARE s r l All rights reserved All trademarks are property of their respective owners TECNOWARE s r l Via Montetrini 2E Loc Molino del Piano 50065 Pontassieve Fl Italy www tecnoware com Edition September 2014 version 1 0 No part of this manual may be reproduced even partially without the authorisation of TECNOWARE s r l TECNOWARE s r l reserves the right to change specifications at any time and without notice UPS ERA LED 1 5 2 0 2 6 1 User s manual Safety Warnings Read this manual carefully and completely before installing and using the TECNOWARE ERA LED Uninterruptible Power Supply which from here after will also be referred to as UPS This manual should be kept close to the UPS and read before the UPS is installed and used The UPS must be used only by properly trained personnel To ensure correct and safe operations it is necessary that operators and maintenance personnel observe the general safety Standards as well as the specific instructions included in this manual Risk of electric shock do not remove the cover The UPS contains internal parts which are at a high Voltage and are potentially dangerous capable of causing injury or death by electric shock There are no internal parts in the UPS which
13. ff and connected to the AC Input Line Battery life strongly depends on the ambient temperature There are also other factors like the number of charge discharge cycles the discharge depth humidity and altitude The recommended environmental specifications for a correct use of batteries are listed in the Technical Specifications section 9 3 Battery Replacement Battery replacement must be performed exclusively by qualified and authorized technical personnel We advise you to follow the steps below explained for greater safety 1 Turn the UPS off and disconnect the AC Input Line for the UPS 2 Unscrew the 4 screws on the UPS bottom side Remove the case cover and so you can access to the battery location Disconnect the battery wires and gently extract batteries from the case The new batteries must be exactly the same type as the original one Put inside the new batteries and connect them as the original one O vw a Ww Reassemble the case cover User s manual 12 UPS ERA LED 1 5 2 0 2 6 Battery replacement must be performed exclusively by qualified technical personnel authorized by TECNOWARE TECNOWARE declines any responsibility if this warning is disregarded When replacing batteries replace with the same type and number CAUTION A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries a Remove watches
14. he computer through USB interface Protects and filters the telephone line Fast swappable battery High efficiency Maximum reliability Smart design and easy to use 3 Receipt and site selection Carefully remove the UPS from its packaging and carry out a meticulous inspection We recommend keeping the original packaging in a secure place in case you need to send the UPS for maintenance purposes In case of transport damage notify the carrier and dealer immediately We recommend paying attention to the below points in order to choose a correct placement for your UPS The UPS is designed to operate in a protected environment e g offices We therefore recommend installing it in a place with very little or no humidity dust or smoke In all circumstances see the Technical Characteristics chapter for environmental specifications and check that the selected area meets these specifications During normal operation the UPS discharges a minimal amount of heat So it is necessary to leave at least 20 cm of unobstructed space all around the UPS in order to keep it properly ventilated Do not obstruct ventilation holes Do not insert objects or pour liquids in the ventilation holes Do not rest any object on top of the UPS Do not keep liquids flammable gases or corrosive substances near the unit Install the UPS on a properly tiled floor Avoid the installation on a floor that is not tiled flat User
15. ntil the AC Input Line returns to normal conditions Electronic board failure Refer to Technical Service Battery Autonomy is too short Battery is not fully charged Recharge the battery for at least 6 hours Electronic board failure Refer to Technical Service OVERLOAD alarm OVERLOAD condition Disconnect all devices that cause the overload condition FAULT alarm FAULT condition Check if UPS is in OVERLOAD condition Refer to Technical Service The UPS does not communicate with The UPS Management Software sends a communication error Check that the USB cable is correctly connected between the UPS and the Computer the Computer The Software is not correctly installed Install correctly the specific Software for your Computer s Operative System If the described anomalies should continue despite the advised troubleshooting or should they manifest in any other form please contact TECNOWARE SERVICE www tecnoware com User s manual 14 UPS ERA LED 1 5 2 0 2 6 CE Conformity to the European Directives TECNOWARE S r l confirms that ERA LED models comply with the requirements set out in the Low Voltage Directive Safety 2006 95 EC and following amendments the EMC Electro Magnetic Compatibility Directive 2004 108 EC and following amendments The following standards were applied Low Voltage Directive Safet
16. ription of anomaly Risk of electric shock do not remove the cover The UPS contains internal parts that are at a high Voltage and are potentially dangerous capable of causing injury or death by electric shock There are no internal parts in the UPS that are user serviceable Any repair or maintenance work must be performed exclusively by qualified technical personnel authorized by TECNOWARE TECNOWARE declines any responsibility if this warning is disregarded Warning to the technical personnel authorized for service since internal components are connected to the batteries they will remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing the positive cable red colour from the positive pole of the battery ANOMALY POSSIBLE CAUSE ACTION TO SOLVE The UPS does not turn on ON OFF button Press the ON OFF button and check that is pushed Batteries are flat Recharge the batteries for at least 4 hours Electronic board failure Refer to Technical Service The UPS always function in Battery mode Input mains power cable is disconnected Check the input mains power cable Check the presence of the electrical mains Input mains fuse is burnt Replace the fuse with another of the same type Black out conditions surge Over Voltage or Low Voltage Wait u
17. tall the UPS indoors in a protected clean and moisture free environment Do not expose to the direct sun light Do not keep liquids flammable gases or corrosive substances near the UPS User s manual 2 UPS ERA LED 1 5 2 0 2 6 1 Introduction ERA LED is a Line Interactive UPS Uninterruptible Power Supply specifically designed to protect your computer from any type of irregularities in the AC line such as black outs under or over voltages micro interruptions which often cause damage to your Hardware and Software Under normal AC line condition ERA LED performs output voltage regulation and filters frequently occurring electrical disturbances such as transients spikes interferences etc thus protecting all devices connected to the outlets and recharging the batteries in an ideal way In case of anomaly to the AC line the UPS continues feeding the protected equipment ERA LED is equipped with USB interface which can be used to notify a power failure or a low battery condition directly to a computer this makes it possible to automatically save your data during an extended black out with the most widespread operating systems Windows Mac OS X Linux etc Read this manual carefully before using the ERA LED it includes important safety warnings and useful advices for correct use and installation This manual is a guide that enables you to correctly install and use your ERA LED This manual includes important SAFE
18. tility line Risk of electric shock at the Output lines while the unit is connected to the AC utility line Risk of electric shock do not remove the cover The UPS contains internal parts which are at a high Voltage and are potentially dangerous capable of causing injury or death by electric shock There are no internal parts in the UPS that are user serviceable Any repair or maintenance work must be performed exclusively by qualified technical personnel authorized by TECNOWARE TECNOWARE declines any responsibility if this warning is disregarded Disregard for these warnings may lead to a risk of electric shock to operators User s manual 8 UPS ERA LED 1 5 2 0 2 6 6 Functioning 6 1 Normal Mode The UPS typically works in Normal mode Input mains power is available and its amplitude is within specifications The Normal mode is identified by the lighting of Line Led in blue color During Normal mode the UPS recharges the batteries and keeps them in an optimal charging voltage 6 2 Battery Mode The UPS automatically runs in Battery mode if the AC Input Line voltage amplitude gets out of security limits in case of a black out or over voltage low voltage in this case the UPS supplies the required output power by its internal battery and by the Inverter block The UPS automatically returns in Normal mode a few seconds after the AC Input Line is recovered The Battery mode is identified by the lighting of
19. y CEI EN 62040 1 2009 EMC Directive Electro Magnetic Compatibility CEI EN 62040 2 2006 Product Disposal UPS ERA LED cannot be disposed as an urban waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of the same or of any parts can be damaging for the environment and for human health A correct waste disposal of products having the dustbin symbol marked by a cross help to avoid negative consequences to the environment and to human health Lay Lead Batteries ERA LED models contain lead acid sealed maintenance free batteries The batteries cannot be disposed as an urban waste but must be treated in conformity with 2006 66 CE European Directive any violation is indictable with financial sanctions as established into 2006 66 CE European Directive P UPS ERA LED 1 5 2 0 2 6 15 User s manual a TECNOWARE po wer systems TECNOWARE s r l www tecnoware com