Home

Thermaltake VENTUS

image

Contents

1. N T escoxe VENTUS By Thermaltake GUI SOFTWARE GUIDE CONTENTS PAGE PAGE PAGE PAGE PAGE 01 1 23 27 28 Main Interface e Main Profiles O Link to Program e Normal Mode Battle Mode O Key Assignment Macro Setting Macro Setting Interface e Macro Manager e Macro Record Setting e Macro Record Timeline Insert Function Performance Setting Performance Interface o DPI e Polling Rate O Lift off Control Light Setting e Light Option Interface Firmware Update e How to Update Firmware CONTENT one Main interface Main Reset Register Guide Close Reset Reset all setting Register Register as Tt eSPORT S s follower and receive updates from Tt eSPORTS via E mail Guide Configuration software manual Close Close Tt eSPORTS VENTUS GUI Software VERSION 1 00 Profile 1 Profile 2 Profile 3 Profile 4 Profile 5 Switch Normal Battle Mode The light frame indicates the Mode Normal Battle you have selected Key Assignment Assign function to each button New Profile Data New Profile Data IL New Profile Data New Profile Data New Profile Data New Profile Data gt LINK TO PROGRAM New Profile Data New Profile Data Apply Cancel OK Apply Click Apply after completing profile setting and it will import setting into VENTUS Cancel Click Cancel if you wish to cancel the setting OK Click OK after setting has been completed Pr
2. DPI Enable Y Axis Key Assignment Sensitivity Level Up Level Down Setting Four Levels of DPI and change DPI by clicking the button Note DPI level will not be cycling back to the first level when it reaches the last DPI sensitivity Y Level up y Level down v Level Setting Level Setting Level Up Level Down Click the Level Setting button to set the DPI level Click the Level Setting button to set the DPI level Level Setting EC EC Click to manage DPI levels You can choose to enable the sensitivity for X Y Axis too Level 1 Level 2 Level 3 Level 4 Level 1 Level 2 3500 3500 3500 dei ESCO 3500 4100 4100 ga aE ga aa jl Enable X Y Axis mi Enable x Axis Apply Key Assignment Sensitivity On The Fly Adjusting DPI level on the fly You can set sensitivity by holding the assignment button and scroll up or down to adjust So you don t need to go through GUI to change your DPI y WV Key Assignment Sensitivity Rotate DPI level will cycle back to the first level when it reaches the highest DPI Sen sitivity Da Y Rotate Level Setting Apply Cancel Level Setting Click to manage DPI levels You can choose to enable the sensitivity for X Y Axis too Level 1 Level 2 Level 3 Level 4 3500 3500 3500 4100 E a jm Enable x Y Axis Apply 4100 AE a I Enable x Axis Apply DI Key Assignment Challenger is the Game Launch Pr
3. Insert key signal in macros that already programmed Insert Delay Time in macros that already programmed First Choose a key that you want in Macro Timeline First Choose a key that you want in Macro Timeline Second Click the INSERT button Second Click the INSERT button Third Select Insert Function Key before this or Key after this Third Select Insert Function Delay time before this or Delay time after this Fourth Select Delay Time mode Fourth Fill in the time for Default Delay Time __ ms that you want to Delay Fifth Click RECORD button and record the macro you wanted to modify Fifth Click INSERT to change the delay time End Click STOP to complete CONTENT THREE Performance Setting A Performance Interface Page 24 DPI DPI setting Page 26 Lift Off Control Adjust the sensor distance Page 25 Polling Rate Adjust Polling Rate Performance Level 1 Level 3 Level 4 A 3900 3500 l 3500 Y 3500 Enable X 1 Axis eL ift off Control Adjustment SPolling rate MHz 125 eal SUO 1000 feu tall 500 1000 Apply Apply Cancel OK APPLY Click Apply you completed the setting CANCEL Click Cancel to cancel the setting OK Click OK after DPI Setting has been fully completed Challenger is the Game O DI DPI Challenger is the Game O Dot Per Inch The Mouse DPI Do you know what is DPI meaning DPI stands for Dot Per Inch is a measurement of how sensitive
4. a mouse is The higher a mouse s DPI the farther the cursor on your screen will move when you move the mouse A mouse with a higher DPI setting detects and reacts to smaller movements DPI levels for each Profile You can choose how many levels of DPI you need for your Profile and you can use up to 4 DPI levels for each profiles Level 1 A 41080 h 2500 Enable 4 1 Axis Enable 4 7 Axis Configure a DPI Configure a DPI for X Y Axis Choose the DPI level by adjusting RED point to your preferred DPI level Choose the DPI level by adjusting both X amp Y Axis Horizontal amp Vertical to your preferred DPI level You can have different DPI level when you move for mouse horizontally and vertically by adjusting the DPI level for both X Y Axis DI Polling Rate Challenger is the Game Polling Rate A higher polling rate could decrease the lag that occurs between when you move your mouse and when the movement shows up on your screen Higher Polling Rate does not mean that you can move fast that will depends on what DPI level sPalling rate Hz 500 1000 Adjust your VENTUS Polling Rate There are 4 levels for Polling Rate to choose from 125 Hz polling rate it s reporting VENTUS s position to the computer 125 times every second Also known as 8ms 250 Hz polling rate it s reporting VENTUS s position to the computer 250 times every second Also known as 4ms 500 Hz polling rate it s reporting VENTUS s position to
5. This make VENTUS a gaming weapon that will enhance your gaming experience NORMAL Normal Mode In Normal Mode Scroll Wheel lights up Tt Dragon light with Pulse break lighting effect Two lights can turn on or off independently Battle Mode In Battle Mode light flash frequency depend on current A P M Scroll Wheel with Pulse break lighting effect Tt Dragon light with Pulse break lighting effect Once mode switched to Battle Mode reminder as below will pop up WARNING When the mode is switched to battle detection the illumination effects will change according to the clicking frequency Key Assignment Customization for each of VENTUS s button Each VENTUS s button can be customized as your preferred even the Scroll Wheel s function can be changed Customize it and make the VENTUS your very own ultimate weapon to conquer VENTUS Can Do More than You Expect Buttons Configuration Click on each button to change its function See right picture New Profile Data Click each button to assign functions New Profile Data O E Mew Profile Data a Key Assignment New Profile Data New Profile Data ni Default New Profile Data Assign macro Mew Profile Data Mew Profile Data Repeat Mew Profile Data Apply Cancel DI Key Assignment Challenger is the Game 6 Key Functions to be Assigned Each of buttons of VENTUS can be assigned by six function Default Macro T Key Sing
6. ger allows you to create delete copy import and export a profile Macro Name Macro Mame Macro Mame NEW DELETE COPY IMPORT EXPORT Manage Macro NEW DELETE COPY IMPORT EXPORT macro NEW Create a new Macro DELETE Delete existing macro COPY Duplicate an existing macro into a new macro IMPORT Import a macro that has been exported EXPORT Export macro into a file Naming Macro You will need to click on the box to change the name for the macro DI Macro record setting Challenger is the Game Macro Record Setting 3 selections provided for you to choose for setting the Delay Time Delay Time Auto Detecting Defult Delay Time ignore Delay Time Macro Delay Time Setting Delay Time Auto Detecting Delay time depend on the time you set the key at Default Delay Time ___ ms Delay time depend on the preferred time set Ignore Delay Time No delay time between key signal Macro record timeline Macro Record Timeline Allow you to program your macro as preferred RECORD STOP DELETE INSERT KEY DELAT TIME RECORD DELETE INSERT Record program Click Record to start recording via your keyboard or mouse and all signal will be recorded on this timeline Delete signal Choose the recorded signal that you wish to delete Once signal has been chosen the background will turn RED as below picture Click Delete and the selected signal will be removed Sto
7. lable for installation You will just need to plug the VENTUS and launch VENTUS s GUI and system will notify you about the new update If you missed or closed the update just re plug in VENTUS and launch VENTUS GUI and system will notify you again Your mouse firmware version is out of date To update now click Ki Cancel 2 ar r e AA VE SAN 7 TAN esPoRTS V CAN fe Thermelteke NOTE Please connect the Tt eSPORT MOUSE to the PC via the USE cable Power on the Tt eSPORT MOUSE start Update a
8. le Key Sensitivity Launch Program Disable Key Mel gnme nt Apply Default All buttons function will be set as default setting i g Left button as the Click action Macro T Key Assign macro that has been recorded from Macro Manager Single Key Set be mouse click function or keyboard per key signal Sensitivity Change DPI function there are 5 mode can be selected Launch Program Launch the pre set program directly Disable Disable button No signal no function Key Assignment Default VENTUS has its own pre configured functions which is the default If you wanted to change back to the default setting you can just choose Default and it will be changed back to the pre configured functions DI Key Assignment Challenger is the Game Macro T Key T Key is the Macro key that you programmed Key Assignment Mac roiT Ke Y Assign macro Apply Cancel Assign macro Select a programmed macro that already recorded from Macro Manager Macro record detail see Page 17 Enter Repeat Count Repeat Customize the times that you want to have the macro repeats Cancel E SI Once Macro will repeat once Multiple Times Multiple Times Macro will repeat depends on the repeat count set When press amp hold M When press amp hold Macro will keep repeating while pressing and holding Until pr Until press next time Macro will start repeating when you click and stop unless y
9. ofile VENTUS has 5 profiles setting Now you can turn on or turn off profile on your command Profile Macro Manager Profile Manager Naming Changing Profile and add delete duplicate import export profile Macro Manager Performance Light Link to Program Performance Adjust VENTUS s DPI Polling Rate Lift off Light Option Change VENTUS light Link to Program Set a program and VENTUS will turn on Profile automatically if you launch the particular program DI Profiles Challenger is the Game Tt eSPORTS 2015 New GUI Tt ESPORTS unveils the new GUI Software in 2014 Many feedbacks from gamers received and we noted all suggestions and experiences from gamers In 2015 Tt eSPORTS launches an enhanced version of GUI The software has been improved user friendly for everyone and can disable profile if you don t need it Turn on off Profile is one of Tt eSPORTS s new GUI feature and this allow gamers to switch profile quickly with just one click We believe Less is More Profile 1 Profile lt Profile 3 Profile 4 Profile 5 Switch to Profile Choose the Profile you wanted to change to Turn On or Turn Off Profile Click the BLUE BOX to enable disable Turn On Light Blue Box Turn Off Grey Blue Box Customization BAME Protile_1 Customization MAME Profile_1 Profile 1 Profile 1 Naming Profile Click the field NAME Profile 1 to name the profile Manage Profile Click
10. ogram Pre set a program and the program will showed up whenever you click on the button that has been programmed Key Assignment Launch Program Launch Program Apply Launch Program button Click the Launch Program button and system will pop out file manager for you to choose the program that you want to launch Key Assignment Disable Choose Disable if you do not want the button have any function for particular buttons Disable 4 CONTENT two Macro Settino Macro setting Interface Macro Manager Macro Mare Create Delete Copy Import Export Me Macro and Modifying Macro Name NEW DELETE IMPORT EXPORT M a C ro R e C O rd Sett i n g en Delay Time Auto Detecting 3 selections for delay time Defult Delay Time ms Ignore Delay Time INSERT vV Key after this jl Delay Time Auto Detecting CT Defult Delay Time ms 1 Ignore Delay Time Insert function Here are many function let you insert time or modify it If you want to insert time or modify program that already set RECT RS p Record Macro Timeline DELETE INSERT AA Record program here KEY DELAY TIME Macro Name COPY RECORD MU SAVE CANCEL Cancel Apply Cancel OK APPLY Click Apply when Macro Setting completed CANCEL Click Cancel to cancel the setting OK Click OK after Macro Setting has been fully completed DI Macro Manager Challenger is the Game Macro Manager Macro mana
11. ou click again Key Assignment Single Key Set only one key per button function can be chose from mouse or keyboard function Mouse function at k Left b utto n Jo L H Keyboard function Current Back Space ASS gn Apply Mouse function Mouse function Click Left button Mouse Function include left picture ClickiLeft button ApplicationiPFught ke Keyboard function You can type any keyboard signal into mouse button Scroll button i g If you set Space as one of the button when you click on the button it will act as Space I E Backward Keyboard function cea Current scroll up Scroll down Assiqn Key Assignment Sensitivity Adjust DPI sensitivity there are 5 different modes to change DPI V lc roo o L Enable X Axis Five different Mode to change DPI as below Temporary Level up Level down Un the thy Rotate DI Key Assignment Challenger is the Game aD Sensitivity Temporary Mode Once DPI level has been set pre set DPI will start when you HOLD the button pre set DPI will stop and back to the original DPI once you RELEASE the button Key Assignment Sensitivity Tem porary Enable X Y Axis Apply Temporary DPI Drag the RED point on the line to adjust DPI Enable X Y Axis Setting X Horizontal movement and Y Vertical movement to have different
12. p program Click Stop whenever recording has been completed Insert signal Click Insert to modify insert signal to existing recorded signal Macro record timeline Macro Record Timeline Once Macro Name and Recording have been completed you can proceed to programming your macro now Switch signal up or down Select the signal and click Up Down to rearrange the recorded signals Note Please be careful while arranging the Press amp Release signal DELAY TIME DEE Off des UE pl Oh DEt DEEL DEt Choose E and press UP or DOWN to arrange DEE DEE DEE Uf des ff DEEL D ft DELAY TIME Uf EE ff URL UE Pl ft st ft 1E das a EE ase IEE EEr ft ff m MZ m C9 A XY 1 A lt jm M E F e B DOD v e t v e e E t ti t e t e t t H4HDD ODA BABA OA RA OA A A A BANAN C9 1 F amp DI Insert Function Challenger is the Game Insert Delay Time or Signal between Key signal If you want to modify or insert Delay time and Key signal to the programmed macro please click the INSERT button to modify the programmed macros INSERT INSERT Key before this Delay time before this RECORD Key after this Delay time after this Delay Time Auto Detecting STOP Defult Delay Time Detult O elay Time INSERT ignore Delay Time CANCEL CANCEL Insert Key Signal before and after Insert Delay Time
13. the Triangle icon to see all profiles created SA A I A Macro Setting E i mi AZ E Click Macro Setting for Macro Advanced Settings u D M y Create Delete Duplicate Import Export Profile DI Link to Program Challenger is the Game Sync Profile with Game Do you ever feel frustrated or forget to switch profile manually while you were in game Now with TteSPORTS 2015 new GUI profile can be automatically switched once you launches a game or a program No more frustration and no more fail to remember Auto Sync Profile with Game now fa LINE TO PROGRAM Link to Program Turn On or Turn Turn ON RED Automatically turn ON with the pre set program when it is enabled A program has to be assigned beforehand Turn OFF GREY Will not turn ON with the pre set program when it is disabled A program has to be assigned beforehand Assign Program Profile will enabled automatically once the program has been launched Click the LINK TO PROGRAM button and system will pop out a file browser for you to choose which program you want to assign TINK TO PROGRAM Turn Off LINK TO PROGRAM Turn On Normal Battle Mode a Light Effect into Game TteSPORTS develop a fancy light effect Just switch the mode and you can experience a different sensation in your place When you are in Battle Mode higher A P M Action Per Minute will have a higher freguency flashes while in lower A P M the flash freguency decreases
14. the computer 500 times every second Also known as 2ms 1000 Hz polling rate it s reporting VENTUS s position to the computer 1000 times every second Also known as 1ms DI Lift Off Control Challenger is the Game O Lift Off Control Lift off trace sometimes required for particular games and some mouse pads that will influence the trace distance and affected gameplay Now with VENTUS this allow gamers to adjust the distance to the best distance they want while gaming ml ift off Control 4djustment Adjust your VENTUS Lift Off Adjust the sensitivity by adjusting the level CAUTION Lowest is not recommended as VENTUS might not be able to sense the mouse pad CONTENT Four Light Settino d Light Option Interface n a Light Option VENTUS LEFT BUTTON HEX Light You can select ON or OFF for HEX light Note HEX Light will still flash to indicate DPI levels although Scroll Wheel light has been turned off m VENTUS Scroll Wheel Light Option You can select ON or OFF for Scroll Wheel light VENTUS Tt DRAGON LOGO Light Option You can select ON or OFF for Tt DRAGON LOGO light Note Tt DRAGON LOGO will have a pulse break light effect Cancel Cancel OK OK Click OK to save the setting CANCEL Click CANCEL to cancel the setting CONTENT rive Firmware Update How to update Firmware Update Your VENTUS Firmware The New GUI can automatically detect new updates whenever there is new update avai

Download Pdf Manuals

image

Related Search

Related Contents

Téléchargez la lettre du cabinet de Novembre    Snapper 151-3845 Lawn Sweeper User Manual  Manual de Instruções Varinha Mágica 7065    下腿用シリコーンライナー - オットーボック・ジャパン  Relación de códigos de causas  BRUTUS SNOW BLADE  POLARÍMETRO POLARIMETER POLARIMÈTRE Modelo  Anhang - Lenze  

Copyright © All rights reserved.
Failed to retrieve file