Home

Neff D39GL64N0 cooker hood

image

Contents

1. en Instructions for installation and use Extractor hood Table of contents INSTRUCTION MANUAL 22 2222220222000200000nnn0nnnnnnnnnnunnnnnunnnnnnnn 2 Important safety information uuuusunnnannnonnnnnnnnnnnnnnenn 2 Environmental protection uuuuu00nnnnnnonnnnnnnnnnnnnnnnnnnnnnn 5 Environmental protection unsseeeeessnneessseeennnnnnnnnnnnnnnnnnnesnnnnnnnnnnnnenn 5 Operating Modes nenne 5 ERNAUST all LOGS ernennen 5 Circulating air One 5 Operation een 6 G ntrol panel model Terre 6 Intensive seting ana cv eucsucacacaion inna 6 Fan TUMON TIO ernennen 6 AirFresh fUNCHION een ie 6 E S A E onan ae 6 Saturation display nennen lesen een ee 6 Audible signal ussseeeesssseeeennssnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnennnennnnnnennnnn 6 Control panel Model neuen 7 Intensive Setting cccccccccsssssscsseecessssssereeesssssseeeeeeessasseeeseeesesssssaeseess T Fan UNON UMIE aeriene oea T AlFe SIUC UO M insin T INSTRUCTION MANUAL Additional information on products accessories replacement parts and services can be found at www neff international com and in the online shop www neff eshop com A Important safety information Read these instructions carefully Only then will you be able to operate your appliance safely and correctly Retain the instruction manual and installation instructions for future use or for subsequent owners The appliance can only be used safely if it is correctly insta
2. EE OAD A E E E TE E T 14 Attaching the TUS Welse 15 This appliance may be used by children over the age of 8 years old and by persons with reduced physical sensory or mental Capabilities or by persons with a lack of experience or knowledge if they are Supervised or are instructed by a person responsible for their safety how to use the appliance safely and have understood the associated hazards Children must not play with the appliance Children must not clean the appliance or carry out general maintenance unless they are at least 8 years old and are being Supervised Keep children below the age of 8 years old at a safe distance from the appliance and power cable Check the appliance for damage after unpacking it Do not connect the appliance if it has been damaged in transport This appliance is not intended for operation with an external clock timer or a remote control Danger of suffocation Packaging material is dangerous to children Never allow children to play with packaging material Danger of death Risk of poisoning from flue gases that are drawn back in Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as room air dependent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the r
3. deviating pipe diameters Installation Preparing the installation Caution Ensure that there are no electric wires gas or water pipes in the area where holes are to be made 1 Mark a vertical centre line on the wall from the ceiling to the lower edge of the extractor hood 2 Mark positions for the screws and the contour of the attachment area 3 Drill five 8 mm holes to a depth of 80 mm for the attachments and press in the wall plugs flush with the wall Checking the wall m The wall must be level vertical and adequately load bearing m The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip m The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks m The max weight of the extractor hood is 40 kg Electrical connection A Risk of electric shock Components Inside the appliance may have sharp edges These may damage the connecting cable Do not kink or pinch the connecting cable during installation The required connection data can be found on the rating plate inside the appliance to do this remove the metal mesh grease filter Length of the cable approx 1 30 m This appliance complies with the EC interference suppression regulations A Risk of electric shock lt must always be possible to disconnect the appliance from the electr
4. off the acoustic signal Repeat the Switching on the acoustic signal process Control panel model 2 Control panel fresh 1 1 vol S dd Explanation D Fan on off Noise reduction Reduce the fan settings fan run on time interval ventila tion Increase the fan settings intensive setting 1 2 P Direct selection of intensive setting 2 Light on off dimming Setting the fan Switching on the appliance m Press the button The fan starts at setting 2 Press the or button to change the fan strength Switching off Press the D button Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Press the button 7 appears in the display Press the button to switch back to the intensive setting F After approx six minutes the electronics automatically reduce the fan to a lower setting If you want to end the intensive setting before this time expires press the button Fan run on time Press the button until L appears After approx ten minutes the fan switches off automatically AirFresh function Press the button until fresh i appears The fan runs for approx five minutes per hour If you want to end the AirFresh function press the button Noise reduction function The noise reduction function reduces the fan noise Switching on the appliance Press the button The function is possible in all fan s
5. original spare parts for your domestic appliance TT Accessories for circulating air mode N not included in the delivery Basic equipment CleanAir recirculation module wide Notes 7 m Follow the installation instructions supplied with the accessories m For appliances with an additional internal filter only the CleanAir recirculation module can be used Basic equipment Starter set for circulating air mode narrow 1 Throw away filter TH Z5101X5 channel width 260 mm Throw away filter Z5101X1 channel width 260 mm 2 75102X5 channel width 345 mm Z5102X1 channel width 345 mm Z5270X0 channel width 260 mm Z51 70X1 channel width 260 mm Z5276X0 channel width 345 mm OO SID or AION Z51 70X1 channel width 345 mm INSTALLATION INSTRUCTIONS min 812 mm max 1153 mm A Important safety information Read these instructions carefully Only then will you be able to operate your appliance safely and correctly Retain the instruction manual and installation instructions for future use or for subsequent owners The appliance can only be used safely if it is correctly installed according to the safety instructions The installer is responsible for ensuring that the appliance works perfectly at its installation location The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building reg
6. ater Clean using a damp dish cloth and dry with a soft cloth Risk of damage to the electronics from penetrating moisture Never clean operator controls with a wet cloth Do not use any stainless steel clean ers Cleaning the metal mesh grease filters IN Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filter Notes m Do not use any aggressive acidic or alkaline cleaning agents m When cleaning the metal mesh grease filters also clean the holder for the metal mesh grease filters in the appliance using a damp cloth m Ihe metal mesh grease filters can be cleaned in the dishwasher or by hand In the dishwasher Note If the metal mesh grease filters are cleaned in the dishwasher slight discolouration may occur This has no effect on the function of the metal mesh grease filters m Do not clean heavily soiled metal mesh grease filters together with utensils m Place the metal mesh grease filters loosely in the dishwasher The metal mesh grease filters must not be wedged in By hand Note You can use a special grease solvent for stubborn dirt It can be ordered via the Online Shop m Soak the metal mesh grease filters in a hot soapy solution m Clean the filters with a brush and then rinse them thoroughly m Leave the metal mesh grease filters to drain Removing metal mesh grease filter 1 O
7. d carbon filter The different options for operating the appliance in circulating air mode can be found in the brochure Alternatively ask your dealer The required accessories are available from specialist retailers from customer service or from the Online Shop For appliances with an additional internal filter only the CleanAir recirculation module see Accessories for circulating air mode can be used Operation These instructions apply to several appliance variants It is possible that individual features are described which do not apply to your appliance Note Switch on the extractor hood when you start cooking and switch it off again several minutes after you have finished cooking This is the most effective way of removing the kitchen fumes Control panel model 1 Control panel Explanation fresh 1 1 D Fan on off Reduce the fan settings fan run on time interval ventila tion Increase the fan settings intensive setting 1 2 Light on off dimming Setting the fan Switching on the appliance Press the D button The fan starts at setting 2 Press the or button to change the fan strength Switching off Press the D button Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Press the button when the fan is at setting J The intensive setting f is activated Pressing the button again activa
8. ed in order to prevent an accumulation of heat Observe the specifications for your cooking appliance If gas and electric hobs are operated together the largest specified distance applies Only one side of the appliance may be installed directly next to a high sided unit or a wall The distance between the appliance and wall or high sided unit must be at least 50 mm Risk of injury Components inside the appliance may have sharp edges Wear protective gloves The appliance may fall down if it has not been properly fastened in place All fastening components must be fixed firmly and securely The appliance is heavy To move the appliance 2 people are required Use only Suitable tools and equipment Risk of electric shock Components inside the appliance may have sharp edges These may damage the connecting cable Do not kink or pinch the connecting cable during installation Risk of electric shock It must always be possible to disconnect the appliance from the electricity supply The appliance must only be connected to a protective contact socket which has been correctly installed If the plug is no longer accessible following installation of the appliance or a fixed connection is required an all pole isolating switch must be present on the installation side with a contact gap of at least 3 mm The fixed connection must only be installed by an electrician Danger of suffocation Packaging material is danger
9. er work with naked flames close to the appliance e g flambeing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal unless a closed non removable cover is available There must be no flying sparks Hot oil and fat can ignite very quickly Never leave hot fat or oil unattended Never use water to put out burning oil or fat Switch off the hotplate Extinguish flames carefully using a lid fire blanket or something similar When gas burners are in operation without any cookware placed on them they can build up a lot of heat A ventilation appliance installed above the cooker may become damaged or catch fire Only operate the gas burners with cookware on them Operating several gas burners at the same time gives rise to a great deal of heat A ventilation appliance installed above the cooker may become damaged or catch fire Never operate two gas burners simultaneously on the highest flame for longer than 15 minutes One large burner of more than 5 kW wok is equivalent to the power of two gas burners Risk of burns The accessible parts become very hot when in operation Never touch hot parts Keep children at a safe distance Risk of injury Components inside the appliance may have sharp edges Wear protective gloves tems placed on the appliance may fall down Do not place any objects on the appliance The light emitted by LED lights is very dazzling and can da
10. es service is there for you if your appliance needs Basic equipment Starter set for circulating air mode wide to be repaired We will always find the right solution in order to avoid unnecessary visits from a service technician 3 When calling us please give the product number E no and the production number FD no so that we can provide you with the correct advice The rating plate with these numbers can be found inside the appliance remove the metal mesh grease filter to gain access You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Throw away filter E no FD no A After sales service Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Basic equipment CleanAir recirculation module narrow Please find the contact data of all countries in the enclosed 5 customer service list To book an engineer visit and product advice GB 0844 8928989 Calls from a BT landline will be charged at up to 3 pence per minute A call set up fee of up to 6 pence may apply IE 01450 2655 0 03 per minute at peak Off peak 0 0088 per minute Throw away filter Trust the expertise of the manufacturer and rest assured that the repair will be carried out by trained service technicians 6 using
11. ettings except in fan setting i It also remains active after the fan is switched off Switching off the appliance Press the button Lighting The lighting can be switched on and off independently of the fan Press the button Setting the brightness Press and hold the button until the desired brightness is reached Saturation display When the metal mesh grease filters or the activated carbon filter are saturated a signal sounds for approx 4 seconds after the fan is switched off In addition this symbol is indicated on the display z If you have not yet done so the metal mesh grease filters should be cleaned now For instructions on how to clean the metal mesh grease filters please refer to the section Cleaning and maintenance While the saturation display is flashing it can be reset To do this press the button Audible signal Switching on the acoustic signal When the fan is switched off press the D and atthe same time for approx three seconds An acknowledgement signal sounds Switching off the acoustic signal Repeat the Switching on the acoustic signal process Cleaning and maintenance A Risk of burns The appliance will become hot during operation especially near the bulbs Allow the appliance to cool down before cleaning A Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a damp cloth only Before cleaning pull out the mai
12. h an activated vapour extractor hood room air is extracted trom the kitchen and neighbouring rooms a partial vacuum is produced if not enough fresh air is supplied Toxic gases from the chimney or the extraction shaft are sucked back Into the living space Adequate incoming air must therefore always be ensured An incoming exhaust air wall box alone will not ensure compliance with the limit safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means XK t In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Danger of death Risk of poisoning from flue gases that are drawn back in If installing a ventilation system in a room with a heat producing appliance connected to a chimney flue the electricity supply to the hood must be equipped with a suitable safety switch Risk of fire Grease deposits in the grease filter may catch fire The specified safety distances must be observ
13. icity supply The appliance must only be connected to a protective contact socket which has been correctly installed If the plug is no longer accessible following installation of the appliance or a fixed connection is required an all pole isolating switch must be present on the installation side with a contact gap of at least 3 mm The fixed connection must only be installed by an electrician 210 300 mm in 812 i min mm a Cee max 1163 mm dr 4 NR 13 Installation Attaching and aligning the appliance 1 Screw on the fixing bracket for the flue duct 1 Initially remove the protective foil from the back of the appliance and following installation remove the foil completely 2 When attaching the appliance ensure that it engages firmly with the brackets BJ 3 Align the appliance horizontally by turning the brackets If required the appliance can be moved to the right or left 2 iE on brackets for the extractor hood hana tight max 3 Nm mE A Securing the appliance 1 Press the safety caps with the arrow upwards onto the brackets until they engage gt 2 Screw on the Knurled nut and washer firmly 3 Screw in threaded pin leaving it protruding out of the wall by 5 9 mm amp Q CG min 5 mm 4 max 9 mm Removing the safety caps If the safety caps must be removed use a flat scre
14. lled according to the safety instructions The installer is responsible for ensuring that the appliance works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation Noise reduction function esssseesssssennnnnnnnnnsennnnnnnnnsnennnnnnnnnnnnnnnnnen l E e a E T IENEEEREREINELEUENERE RE EEHESEN 7 CAMO TSO gt Fane sacunsaisaneansnnsanadteianauheuaseceatanieeue N 7 Audible signal cccccccssssssssecessssesecensesssseneeeeessssseneeeeeesssenstenessags T Cleaning and maintenance zu222220000000000nnnnnnnnnnnnnenn 8 Trouble shooting 9 After sales service aa ana ann nenne 10 Accessories for circulating air MOde eeesenesensseeeennnnennneneeennnn 10 INSTALLATION INSTRUCTIONS 22 2222222202202n00002n000020 11 Important safety information uuuuu00nnannnonnnnnnnnnnnn 11 General information u 22220002nnn000nnnnnnnnnnnnnnnnnnnn nn 13 EXxnauUst ar MOJE ee ee ee mern 13 E A EGUO aa A ee er 13 Checking the wall een lo fae IAG SOHN EL ON ee een one 13 WIGS CA A OWN UPPRESDEERPBEREBERIANEFBEBEEHFNETNFEEREDSERTESEREERTURTEREENEENBEEEFEREEFSER 13 Preparing the installation ececeeseceesessssteeeeeessssseeeeeeessseaeeees 13
15. mage the eyes risk group 1 Do not look directly into the switched on LED lights for longer than 100 seconds Risk of electric shock A defective appliance may cause electric Shock Never switch on a defective appliance Unplug the appliance from the mains or switch off the circuit breaker In the fuse box Contact the after sales Service Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Penetrating moisture may cause an electric shock Do not use any high oressure cleaners or steam cleaners Causes of damage Caution Risk of damage due to corrosion Always switch on the appliance while cooking to avoid condensation Condensate can produce corrosion damage Always replace faulty bulbs to prevent the remaining bulbs from overloading Risk of damage due to ingress of humidity into the electronic circuitry Never clean operator controls with a wet cloth Surface damage due to incorrect cleaning Clean stainless steel surfaces in the direction of the grain only Do not use any stainless steel cleaners for operator controls Surface damage due to strong or abrasive cleaning agents Never use strong and abrasive cleaning agents Risk of damage from returning condensate I
16. ns plug or switch off the circuit breaker in the fuse box A Risk of electric shock Penetrating moisture may cause an electric shock Do not use any high pressure cleaners or steam cleaners A Risk of injury Components inside the appliance may have sharp edges Wear protective gloves Cleaning agents Observe the information in the table to ensure that the different Surfaces are not damaged by using the wrong type of cleaning agent Do not use m harsh or abrasive cleaning agents m cleaning agents with a high concentration of alcohol m hard scouring pads or sponges m high pressure cleaners or steam cleaners Wash new sponge cloths thoroughly before use Follow all instructions and warnings included with the cleaning agents Area Cleaning agents Stainless steel Hot soapy water Clean with a dish cloth and dry with a soft cloth Clean stainless steel surfaces in the direction of the grain only Special stainless steel cleaning prod ucts are available from our after sales service or from specialist retailers Apply avery thin layer of the cleaning oroduct with a soft cloth Painted surfaces Hot soapy water Clean using a damp dish cloth and dry with a soft cloth towel Do not use any stainless steel clean ers Glass cleaner Clean with a soft cloth Aluminium and plastic Glass cleaner Clean with a soft cloth Do not use a glass scraper Glass Operating controls Hot soapy w
17. nstall the exhaust duct in such a way that it falls away from the appliance slightly 1 slope Environmental protection Unpack the appliance and dispose of the packaging in an environmentally responsible manner Operating modes This appliance can be used in exhaust air mode or circulating air mode Exhaust air mode The air which is drawn in is cleaned by the grease filters and conveyed to the exterior by a pipe system Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances m Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed through the outer wall a telescopic wall box should be used Environmental protection X This appliance is labelled in accordance with the European Directive 2012 19 EU concerning used electrical and electronic appliances WEEE waste electrical and electronic equipment The guideline determines the framework for the return and recycling of used appliances as applicable Circulating air mode The air which is drawn in is cleaned by the ar grease filters and an activated carbon filter AR and conveyed back into the kitchen W amp Notes m To bind odours in circulating air mode you must install an activate
18. oom in which they are installed and discharge the exhaust gases Into the open air through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room air is extracted from the kitchen and neighbouring rooms a partial vacuum is produced if not enough fresh air is supplied Toxic gases from the chimney or the extraction shaft are sucked back into the living space Adequate incoming air must therefore always be ensured An incoming exhaust air wall box alone will not ensure compliance with the limit safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means XK t In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filter Grease deposits in the grease filter may catch fire Nev
19. ous to children Never allow children to play with packaging material General information Exhaust air mode A Risk of death Risk of poisoning from flue gases that are drawn back in The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances If the exhaust air is to be conveyed into a non functioning smoke or exhaust gas flue you must obtain the consent of the heating engineer responsible If the exhaust air is conveyed through the outer wall a telescopic wall box should be used Exhaust duct Note The appliance manufacturer does not assume any warranty for complaints attributable to the pipe section m Ihe appliance achieves its optimum performance by means of a short straight exhaust air pipe and as large a pipe diameter as possible m Because of long rough exhaust air pipes many of which are pipe bends or have diameters smaller than 150 mm the optimum extraction performance is not achieved and fan noise is increased m Ihe pipes or hoses for laying the exhaust duct must consist of non combustible material Round pipes An inner diameter of 150 mm but at least 120 mm is recommended Flat ducts The inner cross section must correspond to the diameter of the round pipes 150 mm approx 177 cm 120 mm approx 113 cm m Flat ducts should have no sharp deflections m Use sealing strip for
20. pen the lock and fold down the metal grease filter While doing this place the other hand under the metal grease filter 2 Take the metal grease filter out of the holder For edge extraction filters pull the metal grease filter downwards While doing this place the other hand under the metal grease filter Trouble shooting Malfunctions often have simple explanations Please read the following notes before calling the after sales service A Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table Problem Possible cause Solution The appliance The plug is not Connect the appliance to does not work plugged in the electricity supply Power cut Check whether other kitchen appliances are working Faulty fuse Check in the fuse box to make sure that the fuse for the appliance is OK The bulbs are faulty The lighting does not work For information on chang ing the bulbs see the Replacing Bulbs section For additional filters open the lock and fold down the metal grease filter While doing this place the other hand under the metal grease filter Notes m Grease can accumulate in the bottom of the me
21. tal grease filter m Hold the metal grease filter level otherwise grease will drip out 3 Clean the metal grease filter Installing the metal mesh grease filter 1 Insert the metal mesh grease filter While doing this place the other hand under the metal mesh grease filter 2 Fold the metal mesh grease filter upwards locking it in place Replacing bulbs A Risk of electric shock When changing the bulbs the bulb socket contacts are live Before changing the bulb unplug the appliance from the mains or switch off the circuit breaker in the fuse box Important Only use a bulb of the same type and same power see the bulb holder or rating plate inside the appliance to do this remove the metal mesh grease filter Replacing halogen bulbs Note When inserting halogen bulbs do not touch the glass tube Use a clean cloth to insert the halogen bulbs 1 Carefully remove the bulb ring using a suitable tool 2 Pull out the bulb and replace it with a bulb of the same type 3 Insert the bulb cover 4 Insert the mains plug or switch on the fuse again LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualified technician electrician only A Risk of injury The light emitted by LED lights is very dazzling and can damage the eyes risk group 1 Do not look directly into the switched on LED lights for longer than 100 seconds After sales service Our after sal
22. tes the intensive setting Pe After approx six minutes the electronics automatically reduce the fan to a lower setting If you want to end the intensive setting before the preset time expires press the button until the required fan setting is reached Fan run on time Press the button until L appears After approx ten minutes the fan switches off automatically AirFresh function Press the button until fresh appears The fan runs for approx five minutes per hour If you want to end the AirFresh function press the button Lighting The lighting can be switched on and off independently of the fan Press the button Setting the brightness Press and hold the button until the desired brightness is reached Saturation display When the metal mesh grease filters or the activated carbon filter are saturated a signal sounds for approx 4 seconds after the fan is switched off In addition this symbol is indicated on the display z If you have not yet done so the metal mesh grease filters should be cleaned now For instructions on how to clean the metal mesh grease filters please refer to the section Cleaning and maintenance While the saturation display is flashing it can be reset To do this press the button Audible signal Switching on the acoustic signal When the fan is switched off press the D and atthe same time for approx three seconds An acknowledgement signal sounds Switching
23. ulations and the regulations of the local electricity and gas Suppliers When conveying the exhaust air official and legal regulations e g state building regulations must be followed 4x 2x m This appliance is installed on the wall Follow the enclosed installation instructions for additional special accessories e g for circulating air mode m Ihe surfaces of the appliance are sensitive Avoid damaging them during installation Risk of death Risk of poisoning from flue gases that are drawn back in The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances If the exhaust air is to be conveyed into a non functioning smoke or exhaust gas flue you must obtain the consent of the heating engineer responsible Danger of death Risk of poisoning from flue gases that are drawn back in Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as room air dependent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system e g a chimney In combination wit
24. wdriver Connecting the pipes Note If using an aluminium pipe smooth the connection area beforehand Exhaust air pipe 150 mm recommended size Attach the exhaust air pipe directly to the air pipe connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately Attaching the flue duct A Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective foil from both flue ducts 3 Push one flue duct into the other Notes m To prevent scratches lay paper over the edges of the lower flue duct to protect the surface m Slots of the inner flue duct point downwards 4 Place flue ducts on the appliance 5 Push the inner flue duct upwards and attach it to the fixing brackets on the left and right 6 Press the flue duct downwards until it engages B 7 Screw the flue duct to the sides of the fixing bracket using two screws 15 Constructa Neff Vertriebs GmbH Carl Wery StraBe 34 D 81739 Munchen UL U 111111 9000852731 931007

Download Pdf Manuals

image

Related Search

Related Contents

LED LENSER®*  User Manual Microface E  2011 ARIES LIGHT DUTY PARTS AND SERVICE MANUAL    Robot Café  Instruction manual (pdf file) : Free Download, Borrow, and Streaming : Internet Archive  Stoves Genus 900  Samsung RL34LCSW Priručnik za korisnike  Descargar - Euskaltel  GIR Fast Pack-Multi 501-503P_ES-PT  