Geist G1014 power distribution unit PDU

image

Contents

1. Series PDUs can optionally be configured with a Geist Power Meter that provides local monitoring and display of Current Voltage Wattage and Power Factor Environmental Temperature Operating 10 C 50 F min 45 C 113 F max Storage 259C 13 F min 65 C 149 F max Humidity Operating 5 min 95 max non condensing Storage 5 min 95 max non condensing Elevation Operating O m 0 ft min 2000 m 6561 ft max Storage O m 0 ft min 15240 m 50000 ft max Electrical See nameplate for unit ratings Receptacle Ratings IEC 320 C13 125 250 Volt 15 Amp per Receptacle Bank North American Units IEC 320 C13 125 250 Volt 10 Amp per Receptacle Bank Global Units CAUTION DOUBLE POLE NEUTRAL FUSING CAN BE PRESENT When single pole thermal breakers are used one breaker is provided in the hot conductor path and one breaker is provided in the neutral conductor path The PDU should only be serviced by the manufacturer Receptacle ratings give nameplate component voltage and current ratings Receptacle output voltage will be equal to the voltage of the AC Mains supply used to power the PDU GM1003 Rev 2 3 Rev Date 7 28 2014 Detachable Power Supply Cords Use only detachable power supply cords of the appropriate size and type as stated below with the PDU Use only with light PVC sheathed flexible cords according to IEC 60227 or ordinary tough rubber sheathed flexible cords according to IEC 60245 that termina
2. bracket and toolless mounting buttons attach PDU to rack as shown DETAIL A Single Side Mount 2 Unit Brackets TSMX2 Using single side mount 2 unit brackets and toolless mounting buttons attach PDU to rack as shown GM1003 Rev 2 8 Rev Date 7 28 2014 LEFT SIDE OPTION DETAIL A Offset Side Mount Brackets EZB 1 Using the offset side mount brackets attach PDU to rack as shown EEE EEE DETAIL A j E I d H fl IH a H E a H 4 H i DETAIL B 7 Extension Brackets XB 7 Using the 7 extension brackets attach PDU to rack as shown GM1003 Rev 2 9 Rev Date 7 28 2014 FEE ZE ZE II IX IE EEE ES de DETAIL A Hl Ji Ga EE Flush Mount Brackets FM Using flush mount brackets attach PDU to rack as shown CL XX XE LE ZE XX XE XE XE XE EE EE DETAIL A i H fi i xe ZE XZ xe IX XE IE IE IE IE IE IE IX IE IE IE IE XE TE TE EEE x 7 x Adjustable Mount Brackets AM Using adjustable mount brackets attach PDU to rack as shown GM1003 Rev 2 10 Rev Date 7 28 2014 BE Sor Sr Cox CER EEE ECESESESEOEUE T E DETAIL A SSPE EE AE IE I X XX IE IE X KE X I E AL A IE
3. energize PDU 5 Power on devices Sequential power up is recommended to avoid high inrush current Guidelines If the PDU is installed in a cabinet the ambient temperature of the rack should be no greater than 45 C Install the PDU such that the amount of airflow required for safe operation of equipment is not compromised Mount the PDU so that a hazardous condition is not achieved due to uneven mechanical loading Follow nameplate ratings when connecting equipment to the branch circuit Take into consideration the effect that overloading of the circuits might have on over current protection and supply wiring The PDU relies on the building installation for protection from over current conditions A certified overcurrent protection device is required in the building installation The overcurrent protection device should be sized according to the PDU s nameplate ratings and local national electrical codes Reliable earthing of rack mount equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit The PDU must be connected to an earthed socket outlet The PDU is intended for Restricted Access Locations only and only qualified service personnel should install and access the PDU For pluggable equipment install the PDU so that the input plug or appliance coupler may be disconnected for service Sequential power up of devices powered by the PDU is recommended t
4. I L eee EEE LEE Panel Mount Brackets PM Using panel mount brackets attach PDU to rack as shown SEE XE EE EE HE XE XE HEE XE AE XE XE XE EE EE EE TN DETAIL A 23 Conversion Mounting Brackets 23 RM Using conversion mounting brackets attach 19 PDU to 23 rack as shown GM1003 Rev 2 11 Rev Date 7 28 2014 DETAIL A DETAIL B Cable Mount Bracket CMB 1 Attach cable mount bracket to PDU as shown use tie wraps to secure cords to bracket DETAILA 19 Horizontal Panel Mount Brackets 7938 Using the 19 horizontal panel mount brackets attach PDU to rack as shown GM1003 Rev 2 12 Rev Date 7 28 2014 Optional Local Monitoring Power Meter The Geist PM 1 power meter is a low power high accuracy meter capable of measuring true RMS Current Voltage Power and Power Factor These values are individually shown on an easy to read 4 digit LED Display which continuously scrolls through the four different measured values Each one of these displayed parameters is defined below The Power Meter will automatically begin cycling through the displayed values when the PDU is connected to AC Mains power Current PDU output current draw measured in true RMS Amps Voltage PDU output voltage measured in true RMS Voltage Power PDU output power measured in Watts referred to as real or active power Power Fa
5. _JGEIST Instruction Manual Rack Power Distribution Unit BRE and VRTE Series QOD Go e EI Geist 1821 Yolande Ave Lincoln NE 68521 800 432 3219 402 474 3400 F 402 474 4369 www geistglobal com Contents Specifications eere eere eene nenne nnn nnn Overview Environmental Electrical Receptacle Ratings Detachable Power Supply Cords EMC Verification Installation 32 2 eit urpru p uscrusssuspsucsEEUEsueEES Instructions Guidelines Mounting sassnssnsnsanensnnensnnenensenennenensenennenensenennsnennsnen Optional Local Monitoring sssssnsnnsnsnnsnennenennenennnenn Power Meter Current Meter Service Tech Support eere nnne Service and Maintenance More Technical Support Table of Figures sssssnsansnnanensanensnnenssnensnnensnnensnnennnen Revision History eee eee eere nnne GM1003 Rev 2 Rev Date 7 28 2014 Specifications Overview The BRE and VRTE Series products are Power Distribution Units PDU intended for connection to a 20 Amp AC Mains circuit The BRE and VRTE Series PDUs connect to AC Mains power through an IEC 320 C19 style AC Inlet These PDUs are rated 125 250 Vac 50 60 Hz 16 A and can optionally be configured with single pole thermal breakers or hydraulic magnetic circuit breakers used for supplementary over current protection of the output receptacles The BRE and VRTE
6. ctor Ration of real PDU output power to apparent PDU output power POWER METER POWER t FACTOR Power Meter Display Current Meter The Geist CM 1 current meter is a low power high accuracy meter capable of measuring true RMS Current The value of current is continuously shown on an easy to read 4 digit LED Display The Current Meter will automatically begin to display value of output current when the PDU is connected to AC Mains power CURRENT METER AMPS 7392 Rev A Current Meter Display Real power is the power in a circuit that is transformed from electric to non electric energy while apparent power is the total power supplied to the circuit GM1003 Rev 2 13 Rev Date 7 28 2014 Service Tech Support Service and Maintenance No service or maintenance is required Do not attempt to open the PDU or you may void the warranty No serviceable parts inside It is recommended that power be removed from the unit before installing or removing any equipment More Technical Support http www geistglobal com 800 432 3219 Email support geistglobal com Or contact your distributor GM1003 Rev 2 14 Rev Date 7 28 2014 Table of Figures Full Length Bracket H 6 Mini E Brackets SLB 4 cssccsscssesecnesdoscsventssosxcecotsovsessccessnsessotessusceveecesecteectaseuencdsctoenscssensesosecsecesenavseutsesssesesceesecsteedesssssssenes 6 Vertical Ex
7. o avoid high inrush current Caution Disconnect all power cords before servicing The PDU is intended for use with TN TT or IT power supply systems 3 Branch Circuit should be sized based on the PDU s nameplate electrical rating Global Units should be powered by a 16 Amp circuit GM1003 Rev 2 5 Rev Date 7 28 2014 Mounting 7 it H m t eee gt i DETAILA Full Length Bracket Using the full length bracket mount PDU to rack as shown DETAIL B Mini L Brackets SLB 4 Using the mini L brackets attach PDU to rack as shown GM1003 Rev 2 6 Rev Date 7 28 2014 DETAIL A DETAIL B Vertical Extension Brackets VCB 1 Using the vertical extension brackets attach PDU to rack as shown DETAIL A Toolless Mounting Hardware 11621 Secure toolless mounting buttons to PDU as shown Use toolless buttons with key holed slots built into cabinet or with optional Geist key holed brackets GM1003 Rev 2 7 Rev Date 7 28 2014 TOOLLESS SHOULDER WASHER pA E DETAIL A Toolless Full Length Bracket TLFL Using full length toolless
8. te in an attachment plug meeting local national code requirements For Global units use a minimum 1 5 mm nominal conductor cross sectional area detachable power supply cord with ratings of 300 V and 75 C The power supply cord cable designation should be HO3VV F HO3VVH2 F or better For North American units use a minimum 14 AWG power supply cord with ratings of 300 V and 75 C The power supply cord cable designation should be SJT or better EMC Verification This Class A device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme a la norme NMB 003 du Canada Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment GM1003 Rev 2 4 Rev Date 7 28 2014 Installation Instructions 1 Using appropriate hardware mount PDU to rack see Mounting section for additional instructions 2 Plug PDU into de energized 20 Amp branch circuit receptacle 3 Connect devices into PDU s output receptacles It is recommended that the devices are turned off until all devices are connected to PDU 4 Turn on branch circuit to
9. tension Brackets VCB 1 cis cscccensssnsssocosssssossssessnsessonessnsesencsssssessevenencssosssnscseonsesescetsesssnadsesesssnsesescsssnseseansssnasevetes 7 Toolless Mounting Hardware 11621 ves sooo vosvenseenorsoorsonvennvenseensennsens enne enseenseenseensvennvennvenseenseonsensvensenssenseenseenorsosrsnnvense 7 Toolless Full Length Bracket TEFL avons oanoovoosvensescennennenneenensvensesvennennenneonensvenensvensennennennensvensesvensensennennenseenensvenvenvennenven 8 Single Side Mount 2 Unit Brackets TSMX2 save eee eee eee eese eese eese testen enseensvensrensrsnnvennvenneenseonsennsensenssenseenseensrsosveonvense 8 oscar crdlu4 c p XX Y 9 TY irse crabe resisa 9 Flush M nt Brackets EM DP Sse Sn 10 Adjustable Mo nt Brackets E MUI Dr 10 Panel Mount Brackets dii 11 23 Conversion Mounting Brackets 23 RM ness onveon oonconoosvensesvensennenncenensvensesvensennenneenensvensesvensennenneenenseensesvensensenneen 11 Cable Mount Bracket CMB 1 e 12 19 Horizontal Panel Mount Brackets 7938 4 eee eee Lees eee eese ee eee eese en seta rest to setae etta setas eee so Pesos esten s ease setas eaae esa ae 12 Power Meter Display Me 13 B il
10. ycs Miri Mc R 13 GM1003 Rev 2 15 Rev Date 7 28 2014 Revision History 1 0 4 23 2009 Original Published Version BP 2 0 7 28 2014 Changed logo web address and email QTN GM1003 Rev 2 Rev Date 7 28 2014