1. POWERS CSME OUTPUT may cn OUTPUT amg GSM POWER SOCKET CONTENTS Thank you for purchasing the GSM power socket The GSM power socket is a remotely controlled power socket using any 2G Pay as you Go SIM Not Three as they are purely a 3G Network The power supply output of the socket can be turned on or off remotely by SMS Short Message System command or locally controlled by its function buttons It is an intelligent power socket that can be controlled anytime and anywhere by a mobile phone The GSM power socket is designed for any electrical appliance for business or domestic use up to 13 Amp for the UK version and 16 Amp for the Schuko version with a power consumption of up to 3 Kw It can be used for any type of device and IEC13 conversion cables for PCs and Servers are available When used with the plug in temperature sensor the GSM power socket can switch power on or off according to the environment temperature It is suitable for power control of heating or cooling equipment by keeping the environmental temperature within a pre set range or at a fixed temperature value All services and functions need to be supported by the GSM network and a SIM card This instruction manual provides both a quick start set up and also more advanced settings if the user wishes to programme the GSM power socket by temperature or time date CONTENTS important Informations ea enea aa use seedy cess ae aa eio Safety
2. Main Electricity Supply Restored together with a temperature reading When the external power supply is resumed the output of the GSM socket will keep the same status as that of before the external power supply failure if the power switch of the GSM socket is not turned off For example if the device connected to the GSM power socket was ON before the external power supply was cut off the device will turn back ON when power is restored If the power supply is switched on and off quickly the GSM power socket will send the outstanding SMS messages The GSM power socket will notify the master user when there are any external power changes CHAPTER 3 ADVANCED SETTINGS CHAPTER 3 ADVANCED SETTINGS 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 DEFINING THE USERS 3 1 1 Changing the Master Number 3 1 2 Adding an Additional User Number 3 1 3 Checking Additional User s Number s 3 1 4 Deleting an Additional User Number CONTROLLING THE OUTPUT BY CALLING CONTROLLING THE OUTPUT BY A TIME DELAY CONTROLLING THE OUTPUT BY TIME DATE 3 4 1 Turning ON the Control Output by Time Date Function 3 4 2 Setting the Time Date to Control the Output 3 4 3 Turning OFF the Control Output by Time Date Function CONTROLLING THE OUTPUT BY TEMPERATURE 3 5 1 Turning ON the Control Output by Temperature Function 3 5 2 Setting the Temperature Range to Control the Output 3 5 3 Turning OFF the Control Output by Temperature
3. Function SMS NOTIFICATION UPON THE SOCKET OUTPUT CHANGING CHECKING THE SOCKET STATUS RESETTING THE SOCKET 17 18 CHAPTER 3 ADVANCED SETTINGS 3 1 DEFINING THE USERS 3 1 1 CHANGING THE MASTER NUMBER To change the master number please send the following SMS command to the socket 14 NewMasterNumber 3 1 2 ADDING AN ADDITIONAL USER NUMBER Up to 4 additional user s number s can control this socket Additional users have the authority to turn the socket s output on off To add additional users the master must send the following SMS command 06 AdditionalNumber To add several users at the same time the master must send the following SMS command 06 AdditionalNumber1 AdditionalNumber4 The number required is the additional user s mobile number Successful SMS reply 4 The additional number has been set successfully 3 1 3 CHECKING ADDITIONAL USER S NUMBER S Refer to Chapter 3 7 Check status 3 1 4 DELETING AN ADDITIONAL USER NUMBER To delete an additional user number please send the following SMS command to the socket 113 AdditionalNumber To delete several additional users numbers please send the following SMS command to the socket 113 AdditionalNumber1 AdditionalNumber4 To delete all users additional numbers please send the following SMS command to the socket 113 Successful SMS reply Additional numbers have been deleted Failed SMS reply 4
4. Recommendations Disclaimer NOCE Tarii renion an a E borat eter Sa RSET CHAPTER 1 FEATURES AND ACCESSORIES Tet Mai FUNCIONS saiicta a oa i 132 LISt ORCOMUENUSE 3 N o enai p EAR OEE AAE aE Ajah anra ENE AAEE 1 37 Schematic Drawings nseni neraino a a np a S Ei 1 4 Temperature Sensor Drawing 1 5 LED Light Indicators KEY sei honeen niia ses a O CHAPTER 2 QUICK START 2 1 Installing the SIM Card and Temperature Sensor 00 ccceeeeeeeeeees 13 2 2 Turning the Socket ON OFF wisazckeetansddaedechai ess asd asad ern ah ranean 13 2 37 User AuthOnsation LOVES wcicsisavs cuedaadats rea ebr aea maa neart ius 14 2 4 Setting the Master Number 2 5 Setting the Date Time GMT 2 6 Controlling the Output Power 2 7 Notification of Power Supply LOSS 2 0 0 0 cece cceeeeeeeeeeeeeneeeeee ees 16 CHAPTER 3 ADVANCED SETTINGS Sid Defining TRG USES seve vers cgiaakeanantrnneitandii ei eaa dabooard aia Aas 3 1 1 Changing the Master Number saccra 3 1 2 Adding an Additional User Number 0 0cceeeeeeeeeees 3 1 3 Checking Additional User s Number s ys 3 1 4 Deleting an Additional User Number 0 0ceeeeeeeeees 3 2 Controlling the Output by Calling 2 eee teteeeeeeeeeten ees 3 3 Controlling the Output by a Time Delay A 3 4 Controlling the Output by Time Date n 3 4 1 Turning ON the Control Output by Time Date Function 3 4 2 Setting the Time Date to Control the O
5. The additional number does not exist CHAPTER 3 ADVANCED SETTINGS 3 2 CONTROLLING THE OUTPUT BY CALLING If the master user calls the GSM power socket the socket output will be switched on off automatically when the user hears the ring tone in the phone The call will end automatically if the user doesn t hang up the call By default this function is de activated first the function needs to be enabled To enable this function please send the following SMS command 18 1 To disable this function the master user sends the following SMS command 18 0 Successful SMS reply Control the socket power output status by calling de activated Control the socket power output status by calling activated 3 3 CONTROLLING THE OUTPUT BY A TIME DELAY The GSM power socket can be set by SMS command so there is a delay in turning on or turning off the output of the socket NOTE When the Delayed output function is applied the pre set timed switching of the socket output function will be overridden When any functions of the socket are over ridden i e if the socket output is delayed to turn off after 10 minutes and then you send an SMS command to turn the socket off after 2 minutes the delayed output function will be cancelled This is the same if you set the power socket output to turn on at 9am and turn off at 59m Monday to Friday and the send an SMS to turn the power socket off at 3pm or by pressing the M button to turn the s
6. The socket is not Possible GSM socket fault Turn the power socket off f responding at all check the SIM card or Do not attempt to programme it except as instructed if there is a reset to factory settings problem please try to resolve it through the general 6 The socket has power The network signal is Try the socket in an area troubleshooting section if the problem cannot be solved contact and the GSM LED light weak or the network is where the signal is your supplier keeps flashing busy stronger The SIM card is locked Unlock the SIM card The SIM card is not active Check with the network provider that the SIM card is still active 7 The socket is replying Another master user is Send the command to The master number already programmed change the master user already exists 8 The socket is replying The command you have Refer to the user manual Invalid format please entered is not in the right check and try again later format or the command does not exist 9 The socket is replying The user is not preset Refer to the user manual No authorisation user within the socket 28 CHAPTER 6 MAIN TECHNICAL APPENDIX SMS COMMANDS LIST 29 Category Function Command Input Power Socket 110 250v 50hZ Time Set the socket time 152 Add a master number 00 Output Power Socket Relay Max 13 Amp Change the master number 14 NewMasterNumber Operating Temperature 10 C to 50 C Add an additional number 06 Add
7. ERATURE 3 5 1 TURNING ON THE CONTROL OUTPUT BY TEMPERATURE FUNCTION The external temperature sensor must be inserted into the I O port of the GSM socket The output status of the socket can then be controlled by the environment temperature automatically If the GSM power socket is being controlled by the delay function or the time date function the temperature control will only be valid when the socket output is on To enable the control by temperature function the master user must send the following SMS command 159 1 21 22 CHAPTER 3 ADVANCED SETTINGS Successful SMS reply Auto controlled by external temperature sensor activated 3 5 2 SETTING THE TEMPERATURE RANGE TO CONTROL THE OUTPUT When the temperature function has been set successfully the scheduled parameters will be saved in the socket These settings are saved in the GSM power socket and will remain until the socket is reset to factory settings If the socket loses external power or the power switch is turned off these parameters are still saved within the socket Heating Description When connected a heating device to the GSM power socket i e in the winter when the temperature is low and the device might be used to turn a heater on to keep the environment warm the mode is heating command code is 0 When the environment temperature goes below than the minimum set value it will turn on the output power on Then when it has reached
8. TION To disable the control by temperature function the master user must send the following SMS command 159 0 Successful SMS reply Auto controlled by external temperature sensor de activated 3 6 SMS NOTIFICATION UPON THE SOCKET OUTPUT CHANGING The GSM power socket will by default notify the master when the socket output has changed The master user can enable disable this SMS notification To disable the SMS notifications the master user must send the following SMS command Turn ON SMS notification s upon the socket output changing Default 11 1 Turn OFF SMS notification s upon the socket output changing 11 0 Successful SMS reply Set no SMS notification when socket output changed Set SMS notification once socket output changed 23 24 CHAPTER 3 ADVANCED SETTINGS 3 7 CHECKING THE SOCKET STATUS To check the socket s operating status the master user sends following SMS command 07 After receiving the SMS command the GSM power socket will send an SMS message confirming the status of the socket LE Number Master Number Status ON Temp 20 Temp Control Function OFF Schedule Control Function OFF Delay Control Function OFF Check socket output status 000 After receiving the SMS command the GSM power socket will send an SMS message confirming the sockets output status LE Status ON Temp 20 Check delayed switch on off the socket parameters 138 After receiving the SMS comman
9. at SIM Card has credit at all times for this product to be effective Master user s SMS command format code content Additional user s number s command format code content password The password must be a four digit number The original password is 1234 The maximum digits that are allowed for the phone number is sixteen The GSM power socket will reply to the user after it receives an SMS command The symbol must not be ignored when typing an SMS command Do not include any spaces within the commands NB Although we recommend PAYG SIMS to be used with the GSM power socket contract SIMS can also be used however PAYG SIM s are much more cost effective as the GSM power socket can only send SMS messages SAFETY RECOMMENDATIONS SAFETY RECOMMENDATIONS This socket is designed for business or domestic use for any appliance not exceeding 13 Amps for UK version and 16 Amps for Schuko version or 3 Kw output This socket was designed for indoor use do not use it in a wet chemically aggressive dusty environment o not open up the GSM power socket there are no serviceable parts inside D This socket uses wireless signal transmissions please keep it away from electronic equipment that may be likely to cause interference K S eep the socket and its accessories out of reach of children hould the GSM socket not function as detailed in this instruction book please contact your supplier for technical support I
10. cover you will see a SIM card holder See 8 on 2 2 TURNING THE SOCKET ON OFF Figure 1 2 3 USER AUTHORISATION LEVEL 3 Slide the metallic cover of the holder in the direction of OPEN then lift 2 4 SETTING THE MASTER NUMBER he metallic cover up and towards you 2 5 SETTING THE DATE TIME GMT 4 Put the SIM card with the gold contacts face down and the slight corner cut out of the SIM at the bottom left 2 6 CONTROLLING THE OUTPUTPOWER 5 Slide back the metallic cover in the direction of LOCK and make sure 2 7 NOTIFICATION OF POWER SUPPLY LOSS he SIM card locks into place 6 The SIM card will be fixed in the holder N Insert the temperature sensor into the I O port see 3 Figure 1 2 2 TURNING THE SOCKET ON OFF 1 Turn the power switch to ON position see 7 on Figure 1 2 Plug the GSM power socket into a UK 13 Amp Schuko socket 3 The Green power light will illuminate and the Blue GSM light will flash for about 20 seconds before staying on constantly to confirm GSM signal is available PLEASE MAKE SURE THE SIGNAL IN THE AREA IS GOOD 4 The socket is now ready to be programmed for remote use Note The unit can be turned off by the switch see 7 Figure 1 when not required for a period of time CHAPTER 2 QUICK START 2 3 USER AUTHORISATION LEVEL All settings can be adjusted via SMS command s The GSM power socket has two levels of control Master User Only the master user has authorisati
11. d the GSM power socket will send an SMS message confirming the sockets delay output status I E Status ON Output will cut off after 5 minutes I E Status ON Delay Control function OFF Check Control output by time date function parameters 128 After receiving the SMS command the GSM power socket will send an SMS message confirming the Time Date control parameters I E Schedule control function ON Monday 12 00 15 00 I E Schedule control function OFF Monday 12 00 15 00 Check temperature range control of parameters 159 After receiving the SMS command the GSM power socket will send an SMS message confirming the temperature control parameters I E Status OFF Temp Control OFF Temp 24 Mode Heating Range 20 30 If No temperature sensor connected is received it means the GSM power socket cannot detect the temperature sensor please check if the temperature sensor is inserted to the I O port CHAPTER 3 ADVANCED SETTINGS 3 8 RESETTING THE SOCKET This function resets all programmed settings to their original parameters including deleting all additional users numbers timing parameters and temperature parameters If the setting status is wrong and you have tried re entering the commands the socket can be reset to it s factory settings Note This function needs to be used carefully as it also erases all setting values To reset the GSM power socket to factory sett
12. f the GSM power socket is faulty or the issue cannot be resolved after technical support please contact your supplier DISCLAIMER NOTICE DISCLAIMER NOTICE We operate a policy of continuous development and therefore we reserve the right to make changes and improvements to the design functionally or any part of the socket as described in this document without prior notice For the latest information please contact your supplier We cannot be held responsible in any way should this product be used other than for the intended purpose We accept no responsibility for any loss of income or any damages whether consequential or indirectly and however caused due to the use of this socket CHAPTER 1 FEATURES AND ACCESSORIES CHAPTER 1 FEATURES AND ACCESSORIES 9 CHAPTER 1 FEATURES AND ACCESSORIES 1 1 MAIN FUNCTIONS The GSM power socket uses a PAYG SIM card The GSM power socket is operated remotely by SMS command Output Max 13 Amp for UK version and 16 Amp for Schuko version M button To manually control output power on off Time delayed control of output power on off Auto operation by pre set time times days The GSM power socket is supplied with a plug in external temperature sensor 1 5 LIGHT INDICATORS e Automatic operation by pre set upper lower temperature thresholds on off Receive temperature reading in the location via a simple SMS command Supports 1 master and 4 additional numbers users e Automatic time date synchronizatio
13. g command to set the time 152 Successful SMS reply The time of the device has been regulated automatically 2 6 CONTROLLING THE OUTPUT POWER Method 1 Master Please send the following command to turn the power socket output ON 01 Additional User Please send the following command to turn the power socket output ON 01 password Master Please send the following command to turn the power socket output OFF 02 Additional User Please send the following command to turn the power socket output OFF 02 password Successful SMS reply The socket power output has been switched on The socket power output has been switched off Method 2 Press the M button See 3 on Figure 1 on the side of the socket for 2a second until the output light goes on off and then again to turn the output back on off 15 CHAPTER 2 QUICK START 2 7 NOTIFICATION OF POWER SUPPLY LOSS External power supply lost If the GSM power socket is disconnected from external AC power or a loss of the AC power occurs all functions of the socket are deactivated including the M button and the GSM power socket will notify the master Main Electricity Supply Lost together with a temperature reading External power supply restored If the power socket is reconnected with external AC power or the external AC power is restored and the power socket is available again the SMS notification will be sent to the master
14. ings the master user sends following SMS command 08 Successful SMS reply Reset the socket to factory setting successfully 25 R5 GENERAL TROUBLESHOOTING 27 26 CHAPTER 4 MAINTENANCE CHAPTER 4 MAINTENANCE CHAPTER 5 GENERAL TROUBLESHOOTING No General Trouble Possible Reason Solution e g 1 The power LED has The socket has no power Check that there is turned off supply external power available 2 The GSM LED light has The socket can t find or The SIM card is not turned off identify the SIM card installed correctly power off the socket check the SIM card is inserted Store and use the remote socket responsibly correctly then turn the To maintain the integrity of the GSM ket do not st P o maintain tne integrity o e ower socket GO not store or a inareaswhe s 3 A hi a idity and do not all 3 The M button is not There is no power Check that there is use inargas pia re er IS Very AIgA NUM l y a 2 Q allow turning the output on off available or the power external power available or water or other liquids into the socket otherwise it might cause a socket is off turn the power socket on malfunction 4 The GSM power socket There are insufficient Top up the SIM card with Do not store or use the socket in a dusty environment won t respond to any funds on the SIM card credi commands LED Do not use alcohol acetone and other similar solvents to clean it indicators are working simply wipe with a soft wet cloth 5
15. itionalNumber Define the Add several numbers 06 AdditionalNumber1 Users AdditionalNumber4 Store Temperature 20 C to 60 C Delete an additional number 113 AdditionalNumber Delet addit b 113 AdditionalNumber1 Cete Several adenional NUMOerS AdditionalNumber4 elative Humidi 10 90 Without Condensation elete all additional numbers 113 Relative Humidi Without Cond i Del Il additional b 113 Switch the socket output ON O1 master Communication Protocols GSM Phase 2 2 including data operation ee socket output OFF 024 master Switch the socket output ON Switching additional users FOIA Rasswords on off output Data Interface GSM SIM 1 8V 3 0V Socket manually Switch the socket output OFF 02 Password additional users re he output to switch ON OFF HABHA y Calling External Temperature Sensor 10 C to 50 C j A Disable the output to switch ON OFF 18 0 by calling Default BA Delay switching ON the output 138 1 Minutes ela GSM Working Band EGSM900 DCS1800 ki Delay switching OFF the output 138 0 Minutes 30 APPENDIX SMS COMMANDS LIST APPENDIX SMS COMMANDS LIST Category Timing Control Temperature Control SMS Notifications Checking the Status Reset to Factory Settings Function Enable auto control time date unction Set the time period for the output control to switch ON OFF Disable auto control time date unction Default Enable auto control temperature u
16. n Receive SMS message on external power failure 1 1 MAIN FUNCTIONALITY 1 2 LIST OF CONTENTS 1 3 SOCKET INSTRUCTIONS 1 4 TEMPERATURE SENSOR INSTRUCTION 1 2 LIST OF CONTENTS e 1x GSM power socket e 1x External plug in temperature sensor e 1x User manual 10 CHAPTER 1 FEATURES AND ACCESSORIES CHAPTER 1 FEATURES AND ACCESSORIES 11 1 3 SCHEMATIC DRAWINGS 1 4 TEMPERATURE SENSOR DRAWING Temperature sensor Standard 3 5mm interface bata port Figure 2 Temperature Sensor Drawing Temperature sensor port m button Electrical outlet 1 5 LED LIGHT INDICATORS KEY Indicator Action Status No Light No Mains Power Available Power Light Indicator light Green LED Power GSM Output Constant Light Mains Power Available Socket plugs i a No Light no GSM Signal Socket Switched GSM Blue Light Searching GSM Network Sending Flashing Light an SMS Power switch No Light Socket Power to Connected Device Output Light OFF SIM card holder Red LED c Socket Power to Connected Device onstant ON Figure 1 GSM socket instructions CHAPTER 2 QUICK START CHAPTER 2 QUICK START 13 CHAPTER 2 QUICK START 2 1 INSTALLING THE SIM CARD AND TEMPERATURE SENSOR 1 The power switch should be in the OFF position See 7 on Figure 1 please make sure the power socket is off before inserting the SIM Card 250 INSTALL THE SIM CARD ANDTEMPERATURE SENSOR 2 Open the socket s SIM
17. nction Set the temperature period for the output control to switch ON OFF Disable auto control temperature unction Default SMS notification upon the socket output changing Default No SMS notification upon the socket output changing Check the socket s operating status Check the socket s output status Check the socket s delayed output parameters Check the socket s time date parameters Check the sockets temperature parameters Reset the socket Command 28 1 29 WorkDay StartTime EndTime 28 0 59 1 59 Mode LowTemp HighTemp 59 1 1 1 1 0 07 000 138 128 159 08
18. nd will remain until the socket is reset to factory settings If the socket loses external power or the power switch is turned off these parameters are still saved within the socket To set the time date control parameters the master user sends following SMS command 129 WorkDay StartTime EndTime WorkDay One digit the values lie in the range of 0 to 8 The following table contains the descriptions of each value Value Corresponding Day Value Corresponding Day Value Corresponding Day F Everyday 3 Wednesday 6 Saturday 1 Monday 4 Thursday 0 Sunday 2 Tuesday 5 Friday 8 Monday Friday CHAPTER 3 ADVANCED SETTINGS StartTime and EndTime Consists of 4 digits hh mm and works on a 24 hour clock the StartTime and EndTime should be in the same day and the EndTime must be later than StartTime during the period The socket output will switch on at the StartTime and cut off at the EndTime For example 129 1 0000 2130 0000 is 00 00 AM hh mm 2130 is 9 30PM Successful SMS reply The schedule is set successfully WorkDay StartTime EndTime Timing control the socket activated de activated 3 4 3 TURNING OFF THE CONTROL OUTPUT BY TIME DATE FUNCTION To disable the control by date time function the master user must send the following SMS command 128 0 Successful SMS reply Timing control the socket de activated 3 5 CONTROLLING THE OUTPUT BY TEMP
19. ocket off To reset these functions they need to be turned on again i e by sending 128 1 again the formula does not need to be re entered Sending an SMS command also cancels the temperature range function in the same way as the other examples To delay the output switching ON after a set number of minutes the master user sends the following SMS command 138 1 Minutes To delay the output switching OFF after a set number of minutes the master user sends the following SMS command 138 0 Minutes Minutes are time parameters its range is 0 720 If the minutes are set to O the function will be invalid and the current output status of the socket won t be changed 19 20 CHAPTER 3 ADVANCED SETTINGS Successful SMS reply The socket power output is cut off now will switch on after minutes The socket power output is switch on now will cut off after minutes 3 4 CONTROLLING THE OUTPUT BY TIME DATE 3 4 1 TURNING ON THE CONTROL OUTPUT BY TIME DATE FUNCTION The output of the GSM power socket can be set to switch on for a period To enable the control by date time function the master user must send the following SMS command 128 1 Successful SMS reply Schedule control function ON Sunday 00 00 00 00 3 4 2 SETTING THE TIME DATE TO CONTROL THE OUTPUT When the time date has been set successfully the scheduled parameters will be saved in the socket These settings are saved in the GSM power socket a
20. on to use all the features of the GSM power socket Only one master number can be programmed per socket The master number can be changed to another number by sending an SMS command Additional users Four additional users have authorisation to use two commands to switch on or cut off the socket output The other mobile phone users have no authorisation to use the GSM power socket If there are any changes made to the GSM power socket the master user always gets the notifications 2 4 SETTING THE MASTER NUMBER The user must send the following SMS to the socket from their mobile phone they will then become the master Please send the following command to add a master number 00 Successful SMS reply Welcome to the GSM socket Your password is 1234 Failed SMS reply If a user tries to add another master user the GSM power socket will send an SMS stating The master user already exists to change the master number please refer to Chapter 3 1 4 Please note unless otherwise stated SMS commands to the socket can only be sent by the master user CHAPTER 2 QUICK START 2 5 SETTING THE DATE TIME GMT Important note If the power socket is being used for the first time or it has been reset the master user must set the socket time according to the current time of the SMS centre If the time is not set the power socket will use the original pre set start date time from 00 00 00 1st June 2004 Please send the followin
21. the maximum set value the output will be cut off Cooling Description When connecting a cooling device to the GSM power socket i e in the summer when the temperature is high and the device might be used to turn on an air conditioning unit to keep the environment cool the mode is cooling command code is 1 When the environment temperature goes above the maximum set value it will turn the output power on Then when it has reached the minimum set value the output will be cut off Heating To set the temperature contro parameters the master user sends the following SMS command 159 0 MinimumTempValue MaximumTempValue LE 15940 10 20 When the room temperature is lower than 10 degrees the output power to the device will automatically turn on but when it has reached 20 degrees then the output will be turned off automatically If temperature drops below 10 degrees again the output will be switched on CHAPTER 3 ADVANCED SETTINGS Cooling To set the temperature control parameters the master user sends the following SMS command 159 1 MinimumTempValue MaximumTempValue L E 1594 1 20 30 When the temperature is higher than 30 degrees the output power to the device will automatically turn on but when it has reached 20 degrees then the output will be turned off automatically If the temperature goes above 30 degrees again the output will be switched on 3 5 3 TURNING OFF THE CONTROL OUTPUT BY TEMPERATURE FUNC
22. utput 3 4 3 Turning OFF the Control Output by Time Date Function CONTENTS CONTINUED INFORMATION 5 CONTENTS IMPORTANT INFORMATION 3 5 Controlling the Output by Temperature cece eee teeeee ences e 3 5 1 Turning ON the Control Output by Temperature Function 2 3 5 2 Setting the Temperature Range to Control the Output 3 5 3 Turning OFF the Control Output by Temperature Function 23 3 6 SMS Notification Upon the Socket Output Changing ee 3 7 Checking the Socket Status enaena en 3 8 Resetting THE SOCKON mrar icecenvias attudeneca sei eh raast aan aana aiaia PLEASE READ THIS IMPORTANT INFORMATION The SIM card mobile number is referred to as the GSM socket number CHAPTER 4 MAINTENANCE eere 26 in this manual CHAPTER 5 GENERAL TROUBLESHOOTING 27 Before using this socket check if mobile phones can be used in the area We recommend before choosing your network provider you check the CHAPTER 6 MAIN TECHNICAL eens 28 signal strength of where the socket is to be located and make sure it is stro APPENDIX SMS COMMANDS LIST l a 29 ea S Be sure to keep the password and mobile number safe we recommend you change the pre set password of 1234 and do not disclose this information to anyone other than the authorised users in order to ensure there is no misuse A PAYG SIM Card is required for use in this product please make sure the th