Lumiscope 1137 blood pressure unit
Contents
1. Accuracy Pressure 3 mmHg Pulse Rate 5 Inflation Pump driven Pressure Detection Semi conductor Power Supply 4x AA batteries or AC DC adaptor Auto Power Off Storage Environment Operation Environment External Dimensions 3 minutes after last operation 4 F to 140 F 10 to 95 RH 50 F to 104 F 30 to 85 RH 7 7 L x 5 0 W x 2 4 H or 19 5 L x 12 6 W x 6 2 H cm 380g batteries excluded Standard Cuff accommodates 22 34 cm arm circumference Large Adult Cuff accommodates up to 42 cm arm circumference Standard Cuff Large Adult Cuff Instruction Manual 4 AA alkaline batteries AC Adapter Net Weight Cuff Dimensions Package Contents Note Specifications are subject to modification without prior notice 18 MEMORY FUNCTIONS After measurement the last set of measured values will be saved automatically after measurement when the unit is turned off by pressing button or by automatic power off after 3 minutes 4 1 View Past Readings 1 Press the MEMOA button to enter memory function 2 If the User Page is not what you want to view press the PAGE Y button to select 3 Press the MEMO4 amp button to display the next sets of values for the user selected Past readings are displayed from the most recent to the oldest 4 This blood pressure monitor can store up to 99 sets of past readings for each user 4 x 99 4 2 V
2. SIZE 84 145MM LUMISCOPE For The Quality Of Life Advanced Upper Arm Blood Pressure Monitor Model 1137 Instruction Manual Read these instructions before using your Blood Pressure Monitor Save these instructions for future reference 1137 INS LAB RevA09 PREPARATION 2 1 Battery Installation 1 The battery cover is located on the bottom of the unit To open the battery cover push it inward and lift up 2 Insert 4 AA batteries with the polarities as indicated 3 Replace the battery cover Press it lightly until the lock securely clicks into place 2 2 Connect AC Adaptor Plug the AC 6V adaptor into the AC adaptor jack located at the side of the device next to the blood pressure cuff port Note Remove the batteries when using the AC adaptor SAFETY PRECAUTIONS Babies young children or individuals who cannot express their consent are not suitable for blood pressure measurement e Individuals with serious arteriosclerosis are not suitable for blood pressure measurement Blood pressure readings may fluctuate during pregnancy Pregnant women should consult their doctor before taking measurement e Ifthere are unusual values please consult your doctor before taking medical action Handling batteries properly As soon as batteries wear out replace them with new batteries Do not use old and new batteries together Align the polarities of batteries correctly When th
3. pulse value and HI symbol alternately Example 102 Hl 12 STORAGE amp MAINTENANCE Keep the unit away from direct sunlight extreme temperatures humidity or moisture Use a dry or slightly water dampened cloth to clean the unit Do not use alcohol benzene thinner or other volatile liquids to clean the unit Do not wash the arm cuff or expose it to liquid Remove the batteries from the unit when it will not be used for more than 3 months 17 3 6 WHO Light Indicator This unit features a 6 color LED light indicator to display blood pressure level in accordance with the WHO World Health Organization classification mmHg Grade 3 hypertension severe Red 110 i Grade 2 hypertension moderate o 105 Yellow s A 100 s Grade 1 hypertension mild x Purple o s High normal Green A 85 Normal 80 Sky Blue Optimal Blue 120 130 140 150 160 170 180 mmHg Systolic Pressure WHO Classification Color Optimal Blue Normal Sky Blue High normal Green Mild hypertension Purple Moderate hypertension Yellow WHO Light Indicator Severe hypertension Red Example If your measurement reading is 122 75 the LED light will display the color in blue 13 SPECIFICATIONS Model No Measurement Method Measurement Range 1137 Oscillometric Pressure 20 280 mmHg Pulse Rate 40 195 beats min
4. an turn it off by pressing the button OVERVIEW Monitor Page Select Down Average Values Set WHO Light Indicator Cuff Connector Features Irregular Heartbeat Detector Blood Pressure Mode and Clock Mode 4 User 396 Total Memory 4 Alarm Clock Settings 5 Mode Averaging Function Hour Day Week Month and Overall WHO World Health Organization Blood Pressure Indicator with 6 color LED Auto off Power Saving Feature Operated by 4 AA batteries or AC Adapter included 4 TAKING A MEASUREMENT Note Avoid smoking eating or exercising for 30 minutes before taking a measurement Donot move or talk during measurement Measurement may be taken on either arm however if possible always take measurements on the left arm 3 1 Sitting Correctly 1 Relax 2 Sit upright in a chair with your feet on the floor 3 Remove thick or tight fitting clothing from the upper arm Do not roll up your sleeve if it is too tight 4 Place your arm ona table so that the cuff will be at the same level as your heart 3 2 Applying the Arm Cuff 1 Place your elbow on a table with the palm facing upward Wrap the arm cuff around the upper left arm 2 Pull on the end of the cuff until it wraps securely around your upper arm Do not over tighten the cuff Allow 1 2 cm or Y2 inch between the bottom of the cuff and your elbow joint 3 Make sure the cuff is at the same level as y
5. ashes 2 Press the MEMOA or PAGE V button to select the current year 3 Press the AVG button to confirm Year Setting 4 Follow the same steps to set the Month Date Hour and Minute y C E 2 24 EON izg t ov 5 ON and OFF will then flash This is to have the clock display when the unit is not in use you can choose Clock Function ON or OFF Press MEMOA or PAGE Y button to select Press the AVG button to confirm Note If you select Clock Function ON you will continue at the Alarm Setting section Otherwise setting will end You can set a maximum of 4 alarms T r A 110 ee REE neia E E A GGUGe D GGO AAONJ EGELNE P 6 To disable Alarm Press the MEMOA or PAGE Y button to select OFF and press the AVG button to confirm 7 To set 1st Alarm Press the MEMOA or PAGE V button to select ON Press the AVG button to confirm 8 When Hour digit flashes press the MEMOA or PAGE button to select Hour Press the AVG button to confirm 9 When Minute digit flashes press the MEMOA or PAGEW button to select Minute Press the AVG button to confirm 10 Follow the same steps to set the 2nd 3rd and 4th Alarms Note Press the button anytime during clock setting alarm setting to start over if an error occurs Each alarm lasts 45 seconds or you c
6. e Repair Department voids warranty 19 Symbol on Display 1h One Hour 1d One Day Average Values of 7d One Week 30d One Month All Readings 4 3 Delete Past Readings User can delete all the past readings stored in each User Page 1 Press the PAGEW button to select the User Page you want to delete 2 Press and hold the MEMOA amp PAGEW button simultaneously for 5 seconds Symbol of ALL EE will be displayed and all past readings stored in that User Page will be deleted 15 GF Health Products Inc 2935 Northeast Parkway Atlanta Georgia 30360 telephone 800 347 5678 770 447 1609 fax 800 726 0601 678 291 3232 GRAHAM_FIELD www grahamfield com December 2009 GF Health Products Inc Made in China
7. e unit will not be used for more than 3 months remove the batteries Otherwise batteries may leak and cause damage to the unit Handling the AC adapter Never unplug the power cord with wet hands Use only the original AC adapter designed for this unit QUICK START GUIDE Avoid smoking eating or exercising for 30 minutes before taking a measurement Do not move or talk during measurement Measurement may be taken on either arm however if possible always take measurements on the left arm 1 Sit upright in a chair with your feet on the floor 2 Remove thick or tight fitting clothing from the upper arm 3 Pull on the end of the cuff until it wraps securely around your upper arm Place your arm on a table so that the cuff will be at the same level as your heart 4 Press the ON OFF button to turn on the unit Then press the START button The cuff will automatically inflate and the measurement will start 5 When the measurement is complete the cuff will automatically deflate and your systolic and diastolic pressure values and pulse rate will display 2 3 2 3 Setting the Date and Time 2 4 Setting the Alarm Note Note Set the correct date and time before taking a You will not be able to set the alarm if Clock Function measurement is set to OFF Reset date and time after replacing batteries 1 Press and hold the AVG button for a few seconds until the Year display fl
8. iew Average Readings 1 Press the AVG button to enter Average function 2 If the User Page is not what you want to view press the PAGE V button to select 3 Press the AVG button to view different Average Values 5 different Average Values are available 14 LIFETIME LIMITED WARRANTY GF Health Products Inc offers a lifetime limited warranty on defects in material and workmanship for this product except as noted below This product warranty does not cover damage caused by misuse or abuse the attachment of any unauthorized accessory alteration to the product or any other conditions whatsoever that are beyond the control of GF Health Products Inc GF Health Products Inc shall not be responsible for any type of incidental consequential or special damage To obtain warranty service on your Lumiscope Model 1137 Advanced Upper Arm Blood Pressure Monitor please contact the Lumiscope Repair Department at 1 800 672 8293 There is a 15 fee for return shipping and handling Please make checks payable to GF Health Products Inc Upon receipt we will repair or replace as appropriate the Advanced Upper Arm Blood Pressure Monitore and return it to you This warranty does not include any labor charges incurred in replacement part s installation or any associated freight or shipping charges to GF Health Products Inc Warranty is solely through the Repair Department Service of this product by anyone other than th
9. our heart Left arm Mark cloth Keep 1 2cm between elbow joint and arm cuff Display Date Systolic Time User 1 4 Memory eee Diastolic Pulse Symbol Memory recall 1 99 readings Pulse Value Package Contents Standard Large Adult Arm Cuff Arm Cuff 4x AA Alkaline Batteries 3 3 User Setting This unit allows a maximum of 4 users to store measurement records in different User Pages Press PAGE Y button to switch between User Page 1 2 3 and 4 3 4 Taking a Measurement 1 Press the O button to turn on the unit Then press the START button The cuff will automatically inflate and the measurement will start 2 When the measurement is complete the cuff will automatically deflate and your systolic and diastolic pressure values and pulse rate will display 3 Remove the arm cuff and take note of your measurement results Note You can press the button to stop measurement at any time 3 5 Heartbeat Readings Besides Systolic and Diastolic values Pulse will also be displayed after a measurement 10 SIZE 84 145MM Irregular Heartbeat This unit has a unique feature that alerts user of irregular heartbeat detection during measurement Note An irregular heartbeat is defined as a heartbeat rhythm that has a variation of more than 25 from the average rhythm detected during measurement If an irregular rhythm occurs twice or more during the
10. same measurement the display screen will show the pulse value and IH symbol alternately Example 90 IH Note Please consult your doctor if irregular heartbeat occurs often Regular but Below Normal Heartbeat If the monitor detects a pulse rate below 60 beats per minute during measurement the monitor will display the pulse value and LO symbol alternately Example 58 LO 11 TROUBLESHOOTING Symptom Possible Cause Solution No display when Batteries are Replace with new you press the worn out batteries Power Start button Battery polarities are incorrect Re align batteries in correct polarities Ensure the cuff is properly connected replace the air tube if it is broken Err P displays Failure to inflate Err 1 displays Deflating too rapidly Return for service Movement during measurement Do not move during Err 2 displays measurement Remove interfering source e g mobile phones magnets Signal interference Incorrect results Err 3 displays Measure again Note If your problem cannot be solved by the above consult a GF Health Products Inc representative Refer to the Warranty section of this manual for more information DO NOT disassemble the unit 16 Regular but Above Normal Heartbeat If the monitor detects a pulse rate above 100 beats per minute during measurement the monitor will display the