Home

Olympia Protect 6060

image

Contents

1. NOTE Change the batteries Battery charge empty 1 bAtt off appears in the display The sensor affected e g Open Sen sor01 is displayed 2 If you activate the alarm system 5 successive short acoustic signals are issued NOTE Change the batteries A connection between the sensor and base unit is no longer guaran teed GDC GY Remote Control 1 Use a precision screwdriver to loosen the screw in the battery com partment on the underside of the wireless remote control 2 Remove the cover of the battery compartment Remove the battery contained 4 Insert a new CR2430 3 V lithium battery in the battery compartment ensure correct polarity 5 Replace the cover on the battery compartment 6 Replace and tighten the screw Base Unit The B icon in the display indicates a low battery capacity in the base unit Change the batteries wo 1 Use a screwdriver to loosen the screw in the battery and connection socket compartment on the underside of the base unit 2 Remove the lid from the battery and connection socket compartment 3 Remove the batteries contained 4 Insert three new AAA alkaline batteries in the battery compartment pay attention to correct polarity 5 Replace the lid on the battery and connection socket compartment 6 Replace and tighten the screw OPERATING INSTRUCTIONS Regular Maintenance and Servicing Regular Maintenance and Servicing Base Unit 1 Disconnect the base
2. You can rename the sensor if necessary Confirm it by pressing _OK_ 6 Voice Record appears in the display Press B sc to retain the standard message or press to record an individual message 7 Confirm it by pressing C OK Se NOTE If you do not confirm by pressing the button recording is automatically ended after 10 seconds 8 Your individual message is played back The main menu reappears in the display OPERATING INSTRUCTIONS GDC GY Deregistering Sensors 1 Enter the Entry Code Confirm it by pressing OK 2 Press the 4 button Review appears in the display 3 Press the buttons CA and to select the sensor to be deregistered 4 Press the button Delete appears in the display 5 Confirm it by pressing C 0K Empty appears in the display 6 Press the B sc button twice to exit from the menu System Extension You can order accessories and options for the wireless alarm system via the following web site www olympia vertrieb de Y Products Y Security Products Wireless Alarm Systems Page 27 Changing the Batteries Changing the Batteries If the battery charge of the sensors is low or practically empty the following status messages appear in the display Battery capacity low 1 bAtt Lo appears in the display The sensor affected e g Open Sen sor01 is displayed 2 If you activate the alarm system 5 successive short acoustic signals are issued Ee
3. alarm call numbers and 1 emergency call number SOS can be stored Messages for alarm calls can be set up individually for each re spective sensor up to max 10 seconds long Automatic dialling of the next number when the number called is engaged e Handsfree function on the base unit in the case of an SOS Telephone silent alarm siren alarm can be set individually or com bined Large LC display 1 numeric line in 7 segments for 24 characters 1 alphanumeric line in 5x7 dot matrix for 13 characters 9 icons as status indicators Display lighting in yellow and blue Warning in the event of a low battery charge status base unit and all registered sensors Power failure backup in the base unit Base unit has a remote control facility Upgradable for operation with max 32 sensors Simple integration of new sensors smoke detectors Plug and Play GDC GY Scope of Delivery Base unit Power adapter plug 1 1 Telephone connection cable 1 1 Remote control Batteries 3x alkaline AAA 1x lithium CR2430 3 V Assembly material Screws dowels adhesive tape Operating instructions 1 Please check the contents of the package carefully If anything is missing or has been damaged during transport DO NOT put the wireless alarm system into operation In such cases contact your sales outlet with your purchase receipt to hand or the OLYMPIA service centre LE NOTE Keep the packagin
4. or neighbours In the event of an alarm the internal telephone dialling unit dials these phone numbers automatically in the sequence they were entered beginning with memory location 0 and communicates the status via the voice messages assigned to the respective sensors In the case of an engaged signal or no connec tion is possible the next phone number is automatically dialled A total of three dialling cycles are completed The internal telephone dialling unit is deactivated when a subscriber called answers the call made and presses the numeric key 1 on his telephone or 3 dialling cycles have been completed Ee NOTE Save as many phone numbers as possible This increases the probability of reaching a contact person in the event an alarm is triggered If for example you only save two phone numbers and both are engaged when the alarm call is sent the dialling cycle soon comes to an end Ee NOTE Do not forget to inform the contact persons that they will be called by your alarm system automatically if an alarm is triggered and agree on a sequence of actions if the alarm is triggered OPERATING INSTRUCTIONS GDC CY Configuration Memory locations 0 9 buttons C O to Qwxz are available to enter up to 10 phone numbers Each phone number can be composed of up to 24 characters digits In addition a name with up to 13 characters letters can be assigned to each phone number Ee NOTE Unjustified requests for pol
5. the product itself contained in this document is correct The product and its accessories described in this document are subject to constant improvement and further development For this reason we reserve the right to modify components accessories technical specific ations and related documentation of the product described herein at any time without notice Intended Use The wireless alarm systems from the Protect 6XXX Series enable you to monitor rooms and buildings as long as the local conditions are such that they enable a reliable transmission link to the sensors e g door window contact smoke detector In addition all doors and windows must be equipped with door window contacts A condition for complying with the intended use is that the equipment is installed correctly and the information in this operating instruction manual is observed and maintained Any other use is considered unintended use Unauthorised modifications or reconstructions not described in this operating instruction manual are not permitted and could cause the product to be damaged Furthermore risks through short circuits fire electric shock etc cannot be ruled out GB CE CY Page 5 Product Features Scope of Delivery Product Features Wireless alarm system with emergency call panic room screening and handsfree functions Transmit function to activate outdoor sirens etc Integrated telephone dialling unit with outgoing message Up to 10
6. unit from the power outlet before cleaning it 2 Clean the surface of the housing with a soft lint free cloth Never use any chemicals or scouring agents Ee NOTE Never immerse the equipment in water OPERATING INSTRUCTIONS GB CE CY Page 29 Information on Disposal Information on Disposal The implementation of European law in national laws and direct ives obliges you to dispose of consumable goods appropriately This serves to protect both persons and the environment The adjacent symbol indicates that electrical and electronic apparat us and batteries no longer required must be disposed of separ ate from normal household waste Old or unwanted devices must be disposed of at collection wasa points provided by public waste authorities Batteries and power packs must be disposed of at shops ge which sell batteries or collection points which provide the corres f us ponding containers Packaging materials must be disposed of according to local regulations OPERATING EXGE2CY INSTRUCTIONS Technical Data The wireless alarm systems in the Protect 6XXX Series operate within the frequency band specially reserved for security technology in the 868 MHz frequency range This ensures that interference to the wireless alarm sys tem by other consumer products such as baby monitors is ruled out However it cannot be ruled out that the radio transmission suffers intermit tent or continuous interference due t
7. 28 Base Unit ass reda E T aR N ed en en ne yuna NR YE 28 Regular Maintenance and Servicing 29 B se Unit 4 23 00 2422 y cr a ie sapa aa 29 Information on Disposal 30 Technical Data uu uuu s su au R eee eee 31 Base Unit a ara a NA E ee toner A 31 Remote Control aR s usss eee ha NR RKR Wea ek ee na he 31 Technical Modifications 31 CE Mark 3 2 2 tina as a es 32 OPERATING GB CE CY INSTRUCTIONS Introduction Warranty Dear Customer we are pleased that you have chosen this equipment In the case of a defect please return the device together with the receipt and original packing material to the point of sale OPERATING INSTRUCTIONS Introduction User Information The alarm system is a passive security product and has been conceived as a deterrent Additional measures are necessary to prevent and hinder burglary and theft You can obtain all the necessary information on this from your local police station Read the operating instruction manual thoroughly before connecting and starting the system for the first time The operating instruction manual will help prevent application errors and at the same time ensure you can ex ploit all the technical options provided by the wireless alarm system to the full Disclaimer of Liability We cannot guarantee that the information which relates to the technical properties of the product or to
8. OLYMPIA Protect 6XXX Series Wireless Alarm System Il OLYMPIA fp Instruction Manual 17 12 2012 en Olympia Business Systems Vertriebs GmbH Zum Kraftwerk 1 45527 Hattingen Contents Introduction 5 Configuration cece cece eee nennen 15 Warranty u anere ft tlie ote nel N bates 5 General Information 15 User Information a 22er Ease ta ed eee teed een 5 Selecting the Language 15 Disclaimer of Liability 0 a a Ses eee 5 Enthy Codes s e EE ake eels INITIIERT TUNG 15 Intended Use 24421422242 abd bebe ee eh Ra ee R RT NR ARTE N 5 Setting the Date Time 16 Product Features 6 Individual Outgoing Messages 16 Scope of Delivery ect Velde NA sete Marge ae Ae ted Ann 6 Activating the Internal Telephone Dialling Unit with OGM Function 17 z Savi SOS E Call Number 18 Safety Information 7 ee Emergency Call Number ven Tigger Delay sn teh ee 19 Significance of the Symbols 7 Arming lp lt UT 19 Important Safety Information 7 i Alarm Period re as Ea a SD y Su ei 20 Installation Base Unit 8 j f I i Key Tone On OT irn 20 VL on ae the een
9. S GB CE CY Page 25 Resetting the Factory Settings RESET Resetting the Factory Settings RESET Ee NOTE Please note that when carrying out a RESET all the user settings are deleted The registra tion of the sensors is retained After a RESET has been executed the 4 digit Entry Code is 1 2 3 4 Proceed as follows to reset the factory settings on the wireless alarm sys tem 1 Use a screwdriver to loosen the screw in the battery and connection socket compartment on the underside of the base unit 2 Press the RESET button The alarm system acknowledges a RESET by means of an acoustic signal 3 Close the battery and connection socket compartment and tighten the screw GDC GY OPERATING INSTRUCTIONS Registering and Deregistering Sensors System Extention Registering Sensors Up to 32 sensors can be registered on the wireless alarm system If you purchase optionally available sensors such as additional remote controls smoke detectors etc they must be registered manually Proceed as follows to register the sensors 1 Enter the Entry Code Confirm it by pressing C ox 2 Press the 4 button to open the menu Use the 4 and buttons to select the Register menu option Confirm it by pressing _OK_ 3 Search appears in the display 4 Activate the sensor to be registered To do this please refer to the description supplied with the sensor 5 Open Sensor01 or SmokeSensor01 appears in the display
10. The main menu reappears in the display 6 Press to exit from the menu Entry Code Proceed as follows to change the Entry Code G N 1 Enter the device specific Entry Code Confirm it by pressing C ox 2 The menu is opened by pressing the Menu button 4 briefly 3 Select the Entry Code menu option Confirm it by pressing The default Entry Code appears in the display The first digit flashes Enter the 4 digit Entry Code 4 Confirm it by pressing _OK_ The main menu reappears in the display 5 Note your individual Entry Code down and keep it in a safe place 6 Press to exit from the menu Page 15 Configuration Setting the Date Time 6 Text or numbers which have been entered can be deleted by press ing the X button 1 Enter the device specific Entry Code Confirm it by pressing _oK_ ar iR button j ae c i 7 Voice Record appears in the display Confirm it by pressing 2 The menu is opened by pressing the Menu button 4 briefly Cox D 3 Select the Date Time menu option Confirm it by pressing _OK_ 8 Speak your individual voice message for the selected sensor into the 4 Display 01 01 2010 unit e g BalconyDoor 5 Use the keypad on the base unit to enter the day month and year 9 Press the button to confirm the message and end recording Confirm it by pressing _OK_ gt peat Se NOTE If you do not confirm by pressing the 6 Display 00 00 Se N 1 button recording is automatica
11. a yama Rn 3 a wc a 8 ee 20 Preparing and Connecung MNE Base UMN Ea ETES supai ab Remote Control u uu uuu taa s tuputu atau puas tu EAD 21 Positioning the B Unit aa S E ded bes Seed tide edad Abk 9 ee Flood and Smoke Detectors 21 Wall Installation 9 i 2 S 1 Overview of Monitoring Functions 22 Operating Elements and Indicators 10 ee nu E Switching the Monitoring Functions On Off 22 Function Assignment to Buttons Base Unit 10 Alarmi Modeni utka yy bahaya ku ua ats 23 Display ICONS u ua 8 A es NR KRN RON KR CNN 11 AL Home Mode lt eskera kuonea N 0 NR NEN NR NR NR N RN tan 23 Overview Of LEDS nn ay eerie Tg ne met Du hu 12 Silent Mode ry u a u nee 23 Function Assignment to Buttons Remote Control 12 Disarmed Mode sns ee Sr aa essen ne a en ae 24 Menu Structure 13 OPERATING INSTRUCTIONS GB CE CY Page 3 Contents Panic Alarm r q 9520 ea 24 Emergency Call SOS 24 Remote Access Via Telephone 25 Resetting the Factory Settings RESET 26 Registering Sensors 27 Deregistering Sensors 27 System Extension 27 Changing the Batteries 28 Remote Control res kia
12. d the internal telephone dialling unit is activated delete digits and letters Alarm mode The system is armed on burglary the acoustic alarm signal and internal tele phone dialling unit are activated OPERATING INSTRUCTIONS Operating Elements and Indicators At Home mode The system is armed Display Icons on burglary the acoustic alarm signal is issued 0 9 Digit keys On pressing the button gt 3 sec a 2 sec hat SOS Ca D a o dialling pause is activated In Text mode Switch between upper and lower case j 11 tj De hae O o ooo o O RIRE Tap 11 lt gt Qt 2 ABC2A aaaG abc2 z aa c FERN If an alarm is triggered no acoustic 3 DEF 3 6 E alarm is issued internal telephone def3eeee dialling unit is activated 4 GHI4iiil Alarm mode If an alarm is triggered an acoustic ghi4iiti alarm is issued internal telephone 5 JKL5 dialling unit is activated jkl5 At Home Mode If an alarm is triggered an acoustic alarm is issued GT al Emergency call Internal telephone dialling unit is ac 7 PARSTR tivated pqrs7R Be Time delay Time delay is activated Be TUV S000 U 8 Keylock Key lock is activated tuv8 0 B Internal telephone Connection is being made WXYZ9 dialling unit is ac wxyz9 tivated Recording mode Voice message is being recorded Memory space Indicates the memory location of the display phone number OPERATING INSTRUCTIONS GB CE CY Page 11 Operatin
13. delay To switch off the panic alarm enter your 4 digit Entry Code on the base unit Confirm it by pressing C OK _ Or you can press the button on the remote control GDC GY Emergency Call SOS You can trigger the SOS emergency call function by pressing the button on the base unit or the button on the remote control unit de pending on the configuration The internal telephone dialling unit is auto matically activated when phone numbers have been stored The emer gency call number is dialled first then up to 10 stored phone numbers in succession A voice message requests the subscriber called to press the 1 button on their phone mobile The handsfree function is automatically activated and enables communication between the caller and subscriber called There are three ways to end the SOS function a Enter your 4 digit Entry Code on the base unit and confirm it by pressing the button b Press the button on the remote control c The subscriber called takes the call executes a function with in 24 seconds refer to Activating the Internal Telephone Dialling Unit with OGM Function and then ends the call OPERATING INSTRUCTIONS Remote Access Via Telephone Remote Access Via Telephone K The wireless alarm system can be operated by remote access using a Activate the handsfree function telephone You can use a telephone to activate or deactivate the alarm system and switch the handsfree and screening functions o
14. e display 6 Press to exit from the menu The table below indicates how the flood and smoke detectors are triggered according to the various settings Standard Activate The button on the remote control can be configured as an SOS emer lt Phore call Alarm signal Phone call Alarm signal gency call or Panic button via the base unit awanu Enter the device specific Entry Code Confirm it by pressing C OK 7 At Home mode The menu is opened by pressing the Menu button 4 briefly Silent mode a EE ES Select the Remote Key menu option Contim it by pressing COK Use the CA and buttons to select the Remote SOS or Remote PANIC function 5 Confirm it by pressing C OK 7 The main menu reappears in the display 6 Press B sc to exit from the menu O N OPERATING INSTRUCTIONS GB CE CY Page 21 Monitoring Functions Overview of Monitoring Functions Switching the Monitoring Functions On Off gt EP NOTE Before switching any functions on inform all Internal telephone dialling the other people living in the residence regard function alarm signal unit activated ing the location and method of operation of the Ee NOTE The alarm period of the acoustic alarm is re stricted from a minimum of 1 minute to a max Emergency call mo Yes with handsfree function The wireless alarm system distinguishes between 4 types of alarm en 1 amp Alarm mode alarm signal is issued and interna
15. ems Concrete steel Unshielded electrical apparatus walls GDC GY Preparing and Connecting the Base Unit Ee NOTE The alarm system can also be operated without a telephone connection In the event the alarm is triggered however the internal telephone dialling unit is not activated Power socket O e TAE N connector Telephone connection socket connector 1 Use a screwdriver to loosen the screw in the battery and connection socket compartment on the underside of the base unit 2 Remove the lid from the battery and connection socket compartment 3 Plug the RJ11 connector in the base unit socket 4 Insert three AAA alkaline batteries in the battery compartment pay attention to correct polarity 5 Connect the power adapter plug to the base unit Replace the lid on the battery and connection socket compartment 7 Replace and tighten the screw O OPERATING INSTRUCTIONS Installation Positioning the Base Unit Wall Installation It is possible to setup the device in a user friendly inclined position on a After having found a suitable location for the base unit you can begin with table or desk To do this insert the two legs 1 supplied in the recesses for the installation the wall installation bracket 2 on the rear of the base unit pow i 2 u WARNING Risk of fatal i
16. fuse in the fuse box prior disconnecting the relevant plug from the power socket The wireless alarm system and packaging materials must not be used as toys by children LE NOTE This operating instruction manual contains OPERATING INSTRUCTIONS CDIIEJEN important information on setting up and hand ling the equipment The manual must be en closed with the equipment if handed over to others Page 7 Installation Installation Base Unit Information on Selecting the Installation Location The base unit should be installed or positioned in a central location e g in the hallway of an apartment house in relation to the area to be monitored in order to keep all transmission paths as short as possible Place the base unit in a location where a power socket 230 V 50 Hz and telephone connection socket for the integrated telephone dialling unit are available Choose a location within the area being monitored to ensure that no intruders can approach the base unit and manipulate it The base unit and power adapter plug must not be used in damp rooms cellar bathroom etc or in the direct vicinity of sources of heat The base unit should not be installed setup on or in the direct vicin ity of large metallic objects or sources of electrical interference be cause this reduces the transmission range Examples of sources of interference Metallic objects Source of electrical interference Loudspeaker syst
17. g Elements and Indicators m Seco Function Assignment to Buttons Remote Control Battery indicator Battery capacity of base unit is low Overview of LEDs With power supply Without power supply red yellow red yellow Emergency call or panic function can be optionally con figured on the base unit Alarm mode On burglary acoustic alarm is signal issued and internal telephone dialling unit is activated At Home mode On burglary an acoustic alarm is issued Deactivate key lock on base unit Stop alarm signal Switch alarm system inactive Silent mode on pressing the Alarm and At Home mode buttons simultaneously OPERATING GDY INSTRUCTIONS Menu Structure G Review Register Trigger Delay Arming Delay Flood amp Smoke Remote Key Entry Code OPERATING INSTRUCTIONS Open Sensor01 Voice Record Remote 1 Voice Record Search Open Sensor01 Voice Record Remote 1 Voice Record Duration Delay 0 240S Trigger Tone On Off Delay 0 240S Standard Activate Remote SOS Remote PANIC 1234 GDC CY Menu Structure Page 13 Menu Structure Key Tone Key Tone On Key Tone Off Contrast Contrast 1 5 Language Deutsch Espanol Nederlands Dansk Portugu s English Frangais Date Time 01 01 2010 00 00 Alarm period Time 1 10Min OPERATING GBEICH INSTRUCTIONS Configuration General Information Ee NOTE Before beginning to
18. g in a safe place to protect the equipment from damage should it need to be dispatched in future Ee NOTE This operating instruction manual relates to the base unit of the alarm system The sensors are described in separate manuals OPERATING INSTRUCTIONS Safety Information Safety Information Important Safety Information Please observe the following safety information to ensure the wireless Significance of the Symbols alarm system can be used safely and reliably AN WARNING Indicates potentially dangerous situations If you are uncertain or have any doubts about the functioning meth which could lead to fatal or severe personal od of the equipment during assembly and installation contact a injury if the information is ignored CAUTION Indicates potentially dangerous situations which could lead to minor personal injury if the information is ignored Ee NOTE Indicates potentially dangerous situations which could lead to property or environmental damage if the information is ignored specialist In case of doubt do not complete assembly and installa tion work yourself Never open the equipment Never use the device when it is wet or in the vicinity of a bathtub shower or such Repairs to defective equipment must always be completed by au thorised service technicians Never touch the power adapter plug on the base unit with wet or damp hands If the power adapter plug shows signs of damage disconnect the
19. he wireless alarm system Please note that the Copyright of this operating instruction manual is by Olympia and therefore must not be further copied published or sold in any form The information contained in the operating instruction manual is only intended for personal use C All rights reserved
20. ice fire and rescue services are liable for costs Save the phone numbers as follows 1 Enter the device specific Entry Code Confirm it by pressing C ox 2 Press the button Location Key appears in the display 3 Select a memory location button C O _ CQw z If you have not yet stored a phone number Empty appears as information in the display Confirm it by pressing _OK_ 4 Enter the phone number including the access code Confirm it by pressing _OK_ 5 Enter the name associated with the phone number Confirm it by pressing _OK_ 6 Press to exit from the menu Page 17 Configuration After having entered phone numbers ensure that they are correct in re spect of the alarm calls You can do this by triggering a silent alarm The telephone numbers you have entered are dialled in succession in the pro grammed sequence 1 Enter the device specific Entry Code Confirm it by pressing _oK_ 2 On pressing the key Silent mode is activated Silent mode is indicated in the display by the amp icon after the selected arming delay has expired 3 Now trip the silent alarm on any of the door window contacts e g open door window Ee NOTE When Silent mode is active there is no acous tic alarm signal The display lights up yellow and indicates which sensor has been triggered The internal telephone dialling unit is activated after the trigger delay has expired e The subscriber called takes the call and
21. inactive The acoustic alarm can be switched off via the base unit or the wireless remote control refer to Disarmed Mode in Chapter Monitoring Functions Pressing the SOS emergency call button activates the internal telephone dialling unit as long as phone numbers have been entered and stored beforehand refer to Configuring the Internal Telephone Dialling Unit with OGM Function The unit is activated regardless of whether the alarm system is armed or disarmed The emergency call number is dialled first then up to 10 stored phone numbers in succession A voice message requests the subscriber answering to press the 1 button on their phone The handsfree function is automatically activated on the base unit and enables communication between the caller and subscriber called SR URTE Function Assignment to Buttons Base Unit I ko SS SS fo OLYMPIA Button Emergency Call button Activates the internal telephone dialling unit Confirmation gt E Panic button Triggers an acoustic alarm signal Open the menu scroll up in the menu increase the loudspeaker volume in Handsfree mode Open the Location Key function for phone numbers scroll down in the menu reduce the loudspeaker volume in Handsfree mode m sc gt Disarmed mode The system is deactivated close the menu stop the countdown Silent mode The system is armed when the alarm is trippe
22. l telephone dialling unit is activated 2 ft At Home mode acoustic alarm signal is issued 3 amp Silent mode al telephone dialling unit is activated A message requests the sub scriber called to press the 1 button on their phone mobile The 4 Disarmed mode When Disarmed mode is set the alarm system is deactivated No Yes with screening function wireless alarm system es At Home mode imum of 10 minutes depending on the config No No Yes When Alarm mode is active and an alarm is triggered an acoustic When At Home mode is active and an alarm is triggered only an When Silent mode is active and an alarm is triggered only the intern screening function is activated The monitoring functions are confirmed by a voice message Ee NOTE When triggered the smoke detector always issues an acoustic alarm signal immediately regardless of the wireless alarm system The response of the base unit depends on the type of alarm and setting defined in the Flood amp Smoke menu option OPERATING EXGE2CY INSTRUCTIONS You can define the required type of alarm as follows using either the base unit or the remote control unit supplied ee NOTE If an outdoor siren is registered on the base unit the alarm can only be stopped by the re mote control unit after 15 seconds at the earli est Alarm Mode Ee NOTE You should activate Alarm mode when you leave your apartment or house Before doing so check that all the doors and wind
23. lay You can set an activation delay between 0 and 240 seconds The alarm system is armed after this period has expired You must leave your apart ment house within this period through the door which will subsequently be monitored An acoustic signal is issued by the base unit every second for the period of the set delay time 1 Enter the device specific Entry Code Confirm it by pressing C OK 2 The menu is opened by pressing the Menu button 4 briefly 3 Select the Arming Delay menu option Confirm it by pressing Cok gt 4 Use the CA and buttons to set the required delay time 5 Confirm it by pressing C OK 7 The main menu reappears in the display 6 Press to exit from the menu Page 19 Configuration Alarm Period Key Tone On Off The base unit is equipped with an integrated siren The duration of the It is possible to switch the key tone feature for the base unit on and off acoustic alarm can be selected between a minimum of 1 minute to a max imum of 10 minutes The alarm period is preset to 3 minutes an alarm 1 Enter the device specific Entry Code Confirm it by pressing C ex gt period up to 3 minutes is permitted in Germany 2 The menu is opened by pressing the Menu button CA briefly l ae i 3 Select the Key Tone menu option Confirm it by pressing _OK_ 1 Enter the device specific Entry Code Confirm it by pressing C ox 4 Use the CA and buttons to select the Key Tone On or 2 The menu is
24. lly ended after 7 Enter the time as hour and minute 10 seconds an it by pressing C oK The main menu reappears in the 10 Your individual message is played back The main menu reappears p ay in the display 9 Press miese to exit from the menu 11 Press to exit from the menu Individual Outgoing Messages Ee NOTE You can record an individual message of up to max 10 seconds for each sensor door window contact smoke detector The standard mes sage is replaced by your individual voice mes sage and played when the telephone dialling unit is activated Proceed as follows to record an individual messages for each respective sensor Enter the device specific Entry Code Confirm it by pressing C OK The menu is opened by pressing the Menu button A briefly Select the Review menu option Confirm it by pressing C ox Select the respective sensor required by pressing the 4 and buttons Confirm it by pressing C ox 5 The first letter of the sensor selected flashes You can rename the sensor e g BalconyDoor KitchenWindow etc Confirm it by press ing OK O N OPERATING Page 16 GBIE CH INSTRUCTIONS Activating the Internal Telephone Dialling Unit with OGM Function The internal telephone dialling unit is deactivated if no telephone numbers have been entered and saved You can enter up to 10 individual telephone or mobile phone numbers of contact persons such as relatives friends
25. n Activate the screening function in the room Activate Alarm mode Activate At Home mode ivate Si Ee NOTE The base unit takes your call after 8 rings An swering machines operate according to the same principles of taking a call after a specific number of rings For this reason you must not connect an answering machine to the same telephone connection to which the alarm sys tem is connected Activate Silent mode Activate Disarmed mode End the handsfree or screening function Proceed as follows to operate your alarm system by remote access using 8 End remote access via telephone facility a telephone ey 6 Remote access to your alarm system is interrupted when you press 1 Dial the phone number of the telephone connection to which your the button twice on your telephone alarm system is connected 2 Wait until the alarm system takes the call following the eighth ring You will hear a long acoustic signal LE NOTE As soon as a connection is established with the alarm system Remote appears in the base unit s display 3 Enter your 4 digit Entry Code 4 When you enter the Entry Code correctly you hear 2 short acoustic signals If you enter the Entry Code incorrectly 3 times the connec tion is interrupted 5 Use the keypad on your telephone to execute the following functions refer to table The monitoring functions are confirmed by a voice message OPERATING INSTRUCTION
26. njury through electric shock or gas explosion Pay attention that you do not 1 2 damage electric cables or gas pipes H 7 LJ Ee NOTE Also pay attention to water pipes ny 1 At the installation location insert two screws in the wall 100 mm ee Z apart and aligned horizontally It may be necessary to drill the holes S first and then insert dowels in which to tighten the screws depending A on the properties of the wall 2 Screw the screws in the wall using a screwdriver until there is approx 3 mm clearance from the bottom edge of the screw head to the wall 3 Hook the base unit over the screws 4 Plug the TAE connector in the socket labelled N on the telephone connection socket of your telephone connection 5 Connect the power adapter plug to a properly installed 230 V 50 Hz power socket The base unit is then ready to use OPERATING INSTRUCTIONS GB CE CY Page 9 Operating Elements and Indicators Operating Elements and Indicators The base unit is equipped with an SOS emergency call button for emer gency situations and a Panic button in the event of a direct threat The wireless remote control unit is provided with a button which can be con figured either as an Emergency Call or Panic button refer to Configuring the Wireless Remote Control Unit Pressing the Panic button triggers an immediate acoustic signal intended as a deterrent regardless of whether the alarm system is active or
27. number including the access code Confirm it by pressing _OK_ 5 Enter the name associated with the phone number Confirm it by pressing _OK_ 6 Press to exit from the menu OPERATING EXGE2CY INSTRUCTIONS Trigger Delay The alarm is triggered after a delay so that if someone enters through the main door they can disarm the alarm system before the acoustic alarm and internal telephone dialling unit are activated You can set a trigger delay between 0 and 240 seconds If one of the sensors is tripped the system must be switched to be dis armed for this period so that no alarm is triggered You can select whether an acoustic signal should be issued from the base unit during this period or not 1 Enter the device specific Entry Code Confirm it by pressing _oK_ 2 The menu is opened by pressing the Menu button 4 briefly 3 Select the Trigger Delay menu option Confirm it by pressing 4 Select the Duration menu option Confirm it by pressing ox Use the CA and buttons to set the required delay time 6 Confirm it by pressing the button The system returns to the previous menu level 7 Select the Trigger Tone menu option Confirm it by pressing Ca 8 Use the CA and buttons to select Off or On 9 Confirm it by pressing the button The system returns to the previous menu level 10 Press B sc to exit from the menu ZU OPERATING INSTRUCTIONS GDC CY Configuration Arming De
28. o defective components of other elec trical or electronic products such as ventilators and antenna amplifiers In addition radio transmission can be subject to interference from external sources with wilful intent Base Unit Weight 228 g without batteries Dimensions WxHxD 172 x 105 x 31 mm Frequency 868 MHz Battery 3 AAA alkaline Power adapter plug 6 Vac 500 mA Number of sensors 32 OPERATING INSTRUCTIONS GDC GY Technical Data Remote Control Weight namen 24g Dimensions WxHxD 40 x 60 x 14 5 mm Frequency 868 MHz Battery Lithium CR2430 3 V Technical Modifications This operating instruction manual serves purely for information purposes Its content is not part of any contract for sale All the data relates to nominal values The equipment and options de scribed may differ from country to country according to national require ments Page 31 CE Mark CE Mark The device fulfils the requirements stipulated in the EU Directive 1999 5 EC R amp TTE The CE Mark on the device confirms conformity GDC CY OPERATING INSTRUCTIONS PIN Code This is your individual preset PIN code If you want to change this predefined PIN code please refer to Chapter Configuration in this operating instruction manual Keep this operating manual in a safe place away from t
29. opened by pressing the Menu button 4 briefly Key Tone Off function 3 Select the Alarm period menu option Confirm it by pressing 5 Confirm it by pressing COK The main menu reappears in the Cok D display 4 Use the CA and buttons to set the required alarm period 6 Press to exit from the menu 5 Confirm it by pressing C OK 7 The main menu reappears in the display f Setting the Display Contrast 6 Press Mesc to exit from the menu The display contrast can be adjusted to one of five different settings 1 Enter the device specific Entry Code Confirm it by pressing C ox 2 The menu is opened by pressing the Menu button briefly 3 Select the Contrast menu option Confirm it by pressing _OK_ 4 Use the CA and buttons to adjust the contrast according to your needs 5 Confirm it by pressing C OK 7 The main menu reappears in the display 6 Press to exit from the menu OPERATING GBEICH INSTRUCTIONS Configuration Remote Control Flood and Smoke Detectors Fe You can set up the base unit so that flood and smoke detectors trigger an alarm when the base unit is disarmed 1 Enter the device specific Entry Code Confirm it by pressing C ox 2 The menu is opened by pressing the Menu button 4 briefly 3 Select the Flood amp Smoke menu option Confirm it by pressing Cok 4 Use the CA and buttons to select Standard or Activate 5 Confirm it by pressing C OK 7 The main menu reappears in th
30. operate the base unit de activate the key lock function You need the 4 digit Entry Code to do this The default device specific Entry Code is provided in the battery compartment of the base unit The key lock is reactivated automatically when no buttons are pressed for a period of 10 seconds You can also activate the key lock function manu ally by pressing the button The SOS and Panic buttons are excluded from the key lock function and are always functional Operation The menu is opened by pressing the Menu button 4 briefly Navigate through the menu using the arrow buttons 4 and vo Confirm selections and entries by pressing the button If values are set in certain menus they are accepted and saved Text or numbers which have been entered can be corrected by pressing the button Press the Wesc button briefly to move one menu level back Ifno button is pressed for a period of 10 seconds the menu is auto matically closed and the key lock activated OPERATING INSTRUCTIONS GDC CY Configuration Selecting the Language There is a range of languages available for selection Enter the device specific Entry Code Confirm it by pressing C ox The menu is opened by pressing the Menu button 4 briefly Select the Language menu option Confirm it by pressing C ox Select the language required by pressing the a and buttons 5 Confirm it by pressing C OK
31. ows provided with a door window contact are closed Base unit 1 Enter the device specific Entry Code Confirm it by pressing _oK_ 2 Press the button Remote control 1 Press the button OPERATING INSTRUCTIONS GDC CY Monitoring Functions At Home Mode Ee NOTE During the night when you are asleep you should activate At Home mode Before doing so check that all the doors and windows are closed Base unit 1 Enter the device specific Entry Code Confirm it by pressing C ox 2 Press the button Remote control 1 Press the button Silent Mode ee NOTE When you leave your apartment or house you can activate Silent mode instead of Alarm mode Before doing so check that all the doors and windows are closed Base unit 1 Enter the device specific Entry Code Confirm it by pressing C OK 2 Press the button Remote control 1 Press the and buttons simultaneously Page 23 Monitoring Functions Disarmed Mode Ee NOTE When the system is disarmed you can move freely within the living quarters without trigger ing any alarms Base unit 1 Enter the device specific Entry Code Confirm it by pressing _oK_ Remote control 1 Press the button Panic Alarm You can activate a panic alarm as a deterrent by pressing the button on the base unit or the button on the remote control unit de pending on the configuration The panic alarm is triggered immediately without any
32. the individual message recorded for the sensor triggered is played e The subscriber called is also requested to press digit key 1 on their telephone The screening function is activated This function enables the subscriber to screen the room in which the base unit is located If the subscriber called does not initiate a function within 24 seconds the next phone number is automatically dialled e Silent mode is deactivated by pressing the button on the re mote control entering your Entry Code on the base unit and con firming by pressing the button or when the subscriber called ends the call Saving an SOS Emergency Call Number You can save an SOS emergency call number which is subsequently called first by pressing the button on the base unit or depending on the configuration the button on the remote control Following this number the other phone numbers stored maximally 10 are called in suc cession refer to Activating the Internal Telephone Dialling Unit with OGM Function Save the SOS number as follows Ee NOTE Unjustified requests for police fire and rescue services are liable for costs 1 Enter the device specific Entry Code Confirm it by pressing C ox 2 Press the button Location Key appears in the display 3 Press the button as the selected memory location If you have not yet stored a phone number Empty appears as information in the display Confirm it by pressing C ox 4 Enter the phone

Download Pdf Manuals

image

Related Search

Related Contents

FABRICANTES DE BASCULAS TORREY  Quantum Audio Tape Drives A-Series User's Manual    11285 Profess_Gebranw_Umschlag RZ.indd  搭載していた充電池が発火したラジコンヘリコプター  eky dijital mekanik i̇ng  Manual de instrucciones Balanza compacta  Installation Manual Installation Manual  デイ&ナイトドームカメラ(バリ) KBC  Guide d`administration du systÅ©me de Sun Cluster 2.2  

Copyright © All rights reserved.
Failed to retrieve file