1. Refit the cover and handle Only to be used with alkaline batteries Recovery from a flat battery Should the battery pack become discharged the latch will no longer function This could be in the locked or unlocked state Holding a PP3 9V battery up to the contacts on the bottom of the unit will allow the circuitry to operate normally A valid user card can then be used to open the door to access the batteries Where the lock has a key override this will always be available to unlock the door and gain entry Page 6 PaxLock reset The PaxLock holds address information for the bridge that it is bound to This will cause problems if the unit is to be used on another system The unit requires a hardware reset to clear its bridge information This is achieved as follows Remove the inside handle from the door by loosening the securing grub screw Remove the cover by holding the bottom edge and pulling it towards you The cover will lift off at the top when the bottom edge is clear of the housing Locate the red reset button at the top of the unit Hold the button down and wake up the unit by pressing the front push button The unit will give a beep when the reset has started You can now release the reset button The Red and Green LED s will both flash until the process has finished Refit the cover and handle You can now enrol the unit Specifications esws M oe Loe evens st
2. Disables the door alarm functions Operating mode requires contact switch Reader operatingmodg Events Shows the events for this control unit only Access Rights Lists users who have access through this door Timed operating mo During this timezone At no time This reader will operate as amp Inactive E Acu 00817268 Normal Operation Presenting a valid user token to the unit will cause the LED to briefly flash Green and the door will unlock The presentation of a barred or unknown user token is indicted by a Red LED display The external handle is only engaged once access has been granted The inside handle is always engaged LED indications Net2Air wireless communication The access control unit connects to the Net2 system using Paxton Net2Air proprietary wireless technology through a Net2Air bridge Radio signals do not always behave as you might expect For example a mobile phone that displays a full signal on one part of the site will lose signal completely only a few metres away These problems can be addressed by using the Net2 site surveyor kit 690 200 See also AN1095 Net2 wireless access control How does it work lt http paxton info 974 gt AN1096 How to plan a Net2 wireless installation lt http paxton info 975 gt Ins 30096 Net2Air site surveyor lt http paxton info 1015 gt Radio frequency This product should not be installed within 3 metres of other wi
3. 12 11 2012 Ins 30168 Net2 PaxLock y Paxton Technical Support 6 01273 811011 support paxton co uk Technical help is available Monday Friday from 07 00 19 00 GMT Saturday from 09 00 13 00 GMT Documentation on all Paxton products can be found on our website http www paxton co uk This wireless unit requires a Net2Air bridge to communicate with the server PC Net2Air Site Surveyor 690 200 This access control unit uses wireless communication It is recommended that a Net2Air site surveyor is used to determine the best position for the bridge and control units This unit requires Net2 v4 23 or later software Call Technical Support if you require advice Parts list Front Lock Assembly Rear Lock Assembly Door Handle x 2 Mounting screw short x 2 Mounting screw medium x 2 Mounting screw long x 2 8 mm Spindle AA battery x 4 4 mm Allen Key Tools List Power Drill Small flat blade terminal screwdriver Drill bits 10 mm 16 mm Pencil Philips screwdriver 4mm Allen key supplied Page 1 Installing the hardware Step 1 Marking out The lock case and cylinder not supplied must first be fitted to the door ensuring that a 22 24 mm diameter hole is drilled for the follower As shown on the template provided Slide the spindle through the lock to allow the template to locate over it Ensure that the template is square to the door edge by using the
4. he default setting If this has been turned off it must be enabled in the Server Configuration Utility An entry is then made on the Doors screen and a special icon is used to denote the wireless connection Net2 has NO PaxLock detection function It is recognised that there could be security issues if the wireless units were detectable from outside the site During installation a PaxLock unit binds to a Net2Air bridge which will then only talk to registered units Devices cannot be added to the system if commissioning mode is disabled Page 4 Software Configuration a Net2 Access Control 5 Events ACU serial number 11223344 8 Users Door name TACU 11223344 Access levels f W Timezones E Doors Unlock the door during Apply Door open time second Fea e Cancel Door name Name the Door E Acu 00210856 E Acu 00273223 F Acu 00365237 E Acu 00365522 E acu 00365661 E Acu 00366034 E acu 00425303 E acu 00550276 E acu 00560432 E Acu 00620581 E Acu 00658921 E Acu 00754451 E acu 00787973 E acu 00805012 E acu 00811797 E acu 00815174 Door open time Set the door open time Unlock the Door during Holds the door unlocked during this timezone Set to At No Time for normal user operation Reader Outputs Alam Events Access tights Reader details Mell Reader Local settings for the reader Output Configures the lock for timed release or toggle mode Alarm Enables
5. hernet bridge lt http paxton info 920 gt Download the latest version of Net2 software at http paxton info 1438 before commissioning this product The current specification for compatible PC hardware network and operating systems is available on our website at the following link http paxton info 720 Some of the Net2 features e g Fire alarm integration Anti passback Lockdown are not available on this product as wireless communication is not suitable for data critical applications Enrolling a PaxLock A PaxLock must bind to a Net2Air bridge before it will enrol itself onto the Net2 system The term bind is used to denote the fixed relationship between a wireless unit and its bridge 1 Create a user record in the database and assign a Net2 token to the user This record can be deleted after the installation is complete 2 You must now wake up the PaxLock by using the front push button 3 Present the user token to the PaxLock 4 The Red and Green LED s will flash alternately while the unit configures The PaxLock transmits the number and waits for a response from Net2 If more than one bridge replies the unit checks the signal strength and selects the strongest bridge to communicate with The Net2 software confirms that the token number is in the database and registers the PaxLock bridge binding The LED s will go out when the process has finished The software must be in commissioning mode which is t
6. ored in ACU win no server corner lool C Z years or 30 000 oF in Typical battery life 2 years or 30 000 ops 3 years or 60 000 ops Max Low power mode n Pearrertrequeney PACU per Net2Airbrage Recommended sf O oo o o S o o Net2Air wireless range FP 20m Min environment Max Cee a E A e i mm mm Dimensions Depth Mi Max CE The declaration of conformity is available on request Contact details are provided at http paxton info 596 The Net2 PaxLock is EN1634 1 2008 FD30 and FD60 Fire resistant This product is not suitable for retail sale All warranties are invalid if this product is not installed by a competent person Page 7
7. reless equipment operating on a 2 4Ghz frequency To ensure optimum performance other wireless networks should avoid WiFi channels 1 2 and 3 to reduce the possibility of interference Page 5 Sleep mode The PaxLock is a standalone unit and stays asleep while there is no user activity The Net2 server cannot wake up the unit If the PIR is activated or the front button is pressed it powers up the reader circuits in readiness for a token read Should nothing occur within 3 seconds the unit will go back to sleep If a token is read then the PaxLock moves into full operation The token number is checked against the stored database and access is granted or denied as per a standard Net2 control unit The PaxLock now sends this data via its Net2Air bridge connection to the Net2 server software If any updates need to be sent to the unit including changes to the user data these are transmitted back The unit will then go back to sleep waiting for further activity After 1 hour of inactivity the PaxLock will send a heartbeat to the Net2 PC which responds with any updates This keeps the PaxLock updated even when there is no activity at the door and maximises battery life During the 1 hour sleep period any changes made at the PC will not be received If an immediate update is required the unit must be woken up by pressing the front button or presenting a user card Where a door is held unlocked by software it will still receive updates ever
8. s are provided in three lengths Short Door width 35 mm to 45 mm Med Door width 40mm to 50 mm Long Door width 45 mm to 60mm Step 6 Wiring Plug the wiring harness into the socket in the rear lock assembly Step 7 Wiring contact switch option Where a contact switch is fitted connect the wires to the terminal block provided on the pcb Step 8 Fitting the batteries Clip in the 4 x AA Alkaline batteries with reference to the label displayed below the holder assembly Step 9 Fitting the rear cover Locate the top of the cover over the housing and push flush to the door Page 3 Step 10 Fitting the handles Fit the two handles and secure with the grub screws provided Check the mechanical operation of the lock and that the handles operate freely Software installation The Net2 software should be loaded on the controlling PC and at least one Net2Air bridge configured to communicate with the unit Full documentation is supplied with the Net2Air bridge unit and also on the website as follows AN1051 Installing Net2 software lt http paxton info 1520 gt Ins 30084 Net2Air USB bridge lt http paxton info 926 gt Ins 30085 Net2Air Et
9. top and bottom ruler scales Mark the 2 x 10 mm 1 x 16 mm holes Remove the template and repeat the procedure for the other side Step 2 Drilling Remove the lock if required and drill the 2 x 10 mm holes for the mounting screws and 1 x 16 mm hole for the wiring harness To ensure accuracy you should drill these holes from both sides of the door towards the centre This also avoids the risk of damaging the door face when the drill breaks through Step 3 Contact switch optional If a contact switch is to be fitted an additional hole is required in the edge of the door Drill a hole of the required size to receive the switch assembly This should intersect the 16 mm hole drilled previously to take the wiring harness Feed the contact wires through the door to exit on the inside Step 4 Attach the Spindle The spindle is locked into the front lock assembly by means of a spring loaded pin Ensure that the spindle pin and the hole in the square drive are in alignment before depressing the pin and sliding the bar into the assembly The pin will then latch into the hole securing the spindle in place Page 2 Step 5 Mounting on the door Present the front lock assembly to the door passing the wiring harness through the 16 mm hole Present the rear lock assembly to the door and join the two parts together with the two mounting screws Mounting screw
10. y hour To force an immediate update the unit must by activated by pressing the front button A card can then be presented to initiate the update request Low power mode Low Power mode is available as a global setting in the Net2 server configuration utility or on individual Doors screens It is very useful for units that require low activity but have a high rate of passing traffic e g corridor In low power mode the PaxLock must be woken up by pressing the front button This ensures that incidental handle or PIR activity does not cause an unnecessary drain on battery power or communications activity If woken the PaxLock will initiate a transmission if it has been asleep for more than 1 hour It will always initiate an update every six hours Low battery warning As the battery voltage falls the unit will update the Net2 server with its battery condition This voltage level is displayed as a coloured battery icon alongside the door in the Doors screen When the batteries approach the end of their life an Event is sent to Net2 Using Net2 Trigger and Actions an email or text message can be sent to a staff member or engineer to schedule a battery change Battery replacement Remove the inside handle from the door by removing the securing grub screw Remove the cover by holding the bottom edge and pulling it towards you The cover will lift off at the top when the bottom edge is clear of the housing Remove and replace batteries

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書  DMX USB PRO Mk2 Manual de Usuario  Leading the way to healthy crops. USER GUIDE: Agdia  Midi-Cell - LabWrench  Mode d`emploi  Harbor Freight Tools Single Action Strut Spring Compressor Product manual  Operating instructions Present Weather Sensor OTT Parsivel2  DWM-110 German manual---德国  PV-GS200 - Fine Arts  Bedienungsanleitung  