Home
Posiflex CR-4000N cash box tray
Contents
1. 3 Set S1 for security code to open cash drawer In normal practice the security code is suggested to be a non displayable ASCII character For example a hexadecimal number between 01 to 1F Please refer to rear panel illustration below Part 4 CR4001 4101 4211 4002 4102 4212 4003 4103 4213 Rear panel illustration AC 12V I P PARALLEL O P DB25F Switch is ON when pushed up SERIAL O P DB9M S182 SERIAL I P DB9F PARALLEL I P DB25M GROUND S1 Set security code Default Setting BIT 1 2 3 OFF and BIT 4 5 6 7 8 ON Security code is 07H BIT 1 2 3 4 5 6 7 8 Number to be added to the security code if OFF i Be EE E S2 BIT1 ON and BIT2 OFF to receive security code via Pin2 of P4 DB9F BIT1 OFF and BIT2 ON to receive security code via Pin3 of P4 DB9F BIT3 OFF and BIT4 ON for dedicated RS 232C BIT3 ON and BIT4 OFF for non dedicated RS 232C denotes factory default setting CR4004 4104 4214 6214 1 Open the PC case Put the 616P PHONE JACK metal bracket with power connector into one of the I O windows 2 Connect the cable to the HDD type power connector of PC power d supply See illustration S below Then close the PC powER CORDA case d Part 5 3 Connect the DB 9 connector to the computer s serial port of COM1 or COM2 Connect the 4P phone plug connector to the added I O bracket See below illustration 4PIN PHONE JACK CR4015 4005 II 411
2. 21863018010 which has a 8 pin plug at one end to connect to the cash drawer and a 6 pin plug at the other end to connect to the POS system printer This cable serves for most popularly used POS equipment such as all Posiflex POS terminals all Posiflex POS printers most Epson POS printers most Star POS printers and all other compatibles The user may cut the 6 pin end and assemble this free end according to his POS printer specification if the POS printer used utilizes different connection The cable connection on the wires is as below Wire color Function Drawer open sense Drawer open sense return 24V to solenoid Drawer kick pulse b For CR4001 4101 4211 4002 4102 4212 21863137210 21863237210 with one 9PM and one 9PF connector c For CR4003 4103 4213 21863231810 with one 25PM and one 25PF connector For CR4004 4104 4214 6214 The serial signal cable is already built on e For CR 4015 4005 H 4115 4105 II 4215 II 4225 6015 6215 USB cable is already built on Power Source depend on model a For CR 4000 4020 4100 4210 6210 not applicable b For CR 4001 4101 4211 4002 4102 4212 4003 4103 4213 CR4005 II 4105 II 4215 II 6215 Power adapter 12VAC 1 5A c For CR4004 4104 4214 6214 Power connector cable and I O bracket plate d For CR 4015 4115 4225 6015 There is no power adaptor needed the power source drain from USB port directly Part 3 IN
3. for drawer kickout 4 Install the USB utility driver from Posiflex Product Information CD with Posiflex POS system or visit our web sites http www posiflex com or http www posiflex com tw or http www posiflexusa com for latest updates UPOS driver application Applied for all Posiflex cash drawer Please first find in Posiflex Product Information CDROM or download from Posiflex web sites for UPOS driver setup In this application CR4XX3 and CR4XX4 6214 respond to openDrawer command only CR4XX0 6210 CR4XX1 and CR4XX2 are compliant to UPOS version 1 7 and CR4015 4115 4225 4XX5 II 6015 6215 are compliant to UPOS version 1 8 SPECIFICATIONS MECHANICAL Dimensions 428 W x 460 D x 100 H mm CR 4000 428 W x 456 D x 100 H mm CR 6000 Weight 7 0 Kg CR 4000 8 8 Kg CR 6000 Removable tray with a lock on cover option ELECTRICAL Power Source Solenoid Drive for CR 4000 4020 4100 4210 6210 Pulse Amplitude 12 to 24 VDC Pulse Width 100 to 250 msec Pulse Duty Cycle 10 max Max Current Consumption 0 75A 12 VDC 1 5A 24 VDC AC Adaptor for CR 4001 4101 4211 4002 4102 4212 4003 4103 4213 4005 II 4105 H 4215 II 6215 Input Voltage 120 VAC 10 240 VAC 10 50 60 Hz Output Voltage 12 VAC at 1 5 A Part 7 DC Power Kit for CR 4004 4104 4214 6214 12 V DC and 5 V DC Interface Direct Drive CR 4000 4020 4100 4210 6210 Serial RS232C CR 4001 CR 4002
4. CR 4004 CR 4101 CR 4102 CR 4104 CR 4211 CR 4212 CR 4214 6214 Baud rate 9600 9600 150 19200 Parity None none none even or odd Data Bits 8 8 Tor 8 Stop Bits 1 or 2 lor2 lor2 Parallel IEEE1284 CR 4003 4103 4213 USB 1 1 CR 4015 4005 II 4115 4105 II 4225 4215 II 6015 6215 Security Code CR 4002 4102 4212 4003 4103 4213 1 255 factory preset value 7 CR 4015 4005 II 4115 4105 I 4225 4215 II USB PID CR 6015 6215 Drawer Open Sense CR 4000 4020 4100 4210 Drawer open sense circuit CR 6210 shorts when open CR 4001 4101 4211 4002 4102 4212 Pe ee nn wan drawer open CR 4015 4005 II 4115 4105 II 4225 4215 II CR 6015 6215 Through USB driver KEYLOCK OPERATION Lock D Physically lock the drawer Open CO Open the drawer by the key Standby vy Automatically open the drawer by POS printer or POS system or interface Keylock signal control Part 8 STRUCTURE Check Slot Inside CR 4000 4001 4002 4003 4004 4005 II 4015 4100 4101 4102 4103 4104 4115 4105 II Bill compartment Bill Clip ee EE LEE TREN TS SE SS EY Say Ses Dt eeh OS o Coin compartment Cash Tray Coin Roll Storage Tray for CR 4020 Cash Tray SET Part 9 Tray for CR 4210 4211 4212 4213 4214 4225 4215 II 6210 6214 6015 6215 BiN compartment Coin Roll Storage Bill Weight Coin compartment Caution For CR 4015 CR 4115 CR 4225 C
5. from the furnishing performance or use of this material This information is provided as is and Posiflex Technology Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential hardware concerns for general user and is subject to change without notice Posiflex reserves the right to alter product designs layouts or drivers without notification The system integrator shall provide applicative notices and arrangement for special options utilizing this product The user may find the most up to date information of the hardware from web sites http www posiflex com or http www posiflex com tw All data should be backed up prior to the installation of any drive unit or storage peripheral Posiflex will not be responsible for any loss of data resulting from the use disuse or misuse of this or any other Posiflex product All rights are strictly reserved No part of this documentation may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying or otherwise without prior express written consent from Posiflex Technology Inc the publisher of this documentation Copyright Posiflex Technology Inc 2011 All brand and product names and trademarks are the property of their r
6. 5 4105 II 4225 4215 II 6015 6215 1 Define a drawer number for the cash drawer so that this cash drawer is going to respond accordingly in USB communication Follow the table below for Switch settings to adjust the switch S1 according to this drawer number if it is not 7 Please note that within each system there should never be any 2 USB interface cash drawers carrying the same drawer number Rear View Connect to USB AC12v yp SI Port of Main PC l NS Power Jack of CR4005 II 4105 II USB Connector from CR4015 4005 II 4215 I1 6215 4115 4105 II 4225 4215 H 6015 6215 Rear View of Model CR4015 4005 II 4115 4105 II 4225 4215 II 6015 6215 Cash Drawer with USB Interface For CR 4015 4115 4225 CR 6015 there is no AC power input in back panel Switch settings Drawer 0 1 2 3 4 5 6 7 SW1 ON OFF ON OFF ON OFF ON OFF SW2 ON ON OFF OFF ON ON OFF OFF SW3 ON ON ON ON OFF OFF OFF OFF Sw4 ON Vendor Class OFF HID Class Default setting Drawer 7 SW1 OFF SW2 OFF SW3 OFF SW4 OFF Part 6 2 Connect USB connector of cable coming out from the rear side of the USB interface cash drawer to USB port of main PC 3 Check the specification of power adaptor on its nameplate Insert the power adaptor into the correct power outlet Insert the output plug to the jack at rear side of CR4005 II 4105 H 4215 H 6215 to supply power
7. CR 4000 6000 SERIES POSIFLEX CASH DRAWER USER S MANUAL FCC Notes Rev BO This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual may cause interference to radio communications It has been tested and found to comply with limits for a Class A digital device pursuant to subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures to correct the interference Warranty Limits Warranty terminates automatically when any person other than the authorized technicians opens the machine The user should consult his her dealer for the problem happened Warranty voids if the user does not follow the instructions in application of this merchandise The manufacturer is by no means responsible for any damage or hazard caused by improper application About This Manual Posiflex has made every effort for the accuracy of the content in this manual However Posiflex will assume no liability for any technical inaccuracies or editorial or other errors or omissions contained herein nor for direct indirect incidental consequential or otherwise damages including without limitation loss of data or profits resulting
8. R 6015 which use USB port as power source the drawer kick out duty cycle should not less then 15 seconds otherwise it may not kick out the drawer POSIFLEX S EN 131454 JAE PRN Ba dh gt Hee EHR Sra ch FURR PE ak oe HAF RMAF Re EEN Part 10
9. STALLATION CR4000 4020 4100 4210 6210 Connect the drawer to POS systepp printer as shown below 8P Telephone Plug POS System or Printer E 6P Telephone Plug 8P Telephone Jack CASH DRAWER With Printer Interface CR4001 4101 4211 1 Connect the drawer serial I P port to the computer COM port Connect the power adapter output to the Power Input jack 2 No other RS232C devices should be connected to the serial O P port 3 Set position 3 of S2 to OFF and position 4 of S2 to ON Please refer to rear panel illustration CR4002 4102 4212 1 Connect the drawer serial I P port to the computer COM port Connect the power adapter output to the Power Input jack 2 Other RS232C device can be connected to the serial O P port when needed as long as the security code makes no influence to this RS232C device 3 Set position 3 of S2 to ON and position 4 of S2 to OFF Set S1 for security code to open cash drawer In normal practice the security code is suggested to be a non displayable ASCII character for example a hexadecimal number between 01 to IF Please refer to rear panel illustration below CR4003 4103 4213 1 Connect the drawer parallel I P port to the computer LPT port Connect the power adapter output to the Power Input jack 2 Other parallel device such as a printer can be connected to the parallel O P port when needed as long as the Security code makes no influence to this parallel device
10. espective holders P N 19240901050 Part 1 MODEL NUMBERS CR421X 4225 Model CR400X 4015 CR410X 4115 CR6015 621X Bill Compartment 5 Adjustable 5 Fixed 5 Fixed Bill clip Plastic Metal Metal Coin compartment 9 Fixed 9 Fixed 5 Fixed Coin Roll storage 1 Underneath Cash Tray 4 Behind Cash Tray Note 1 CR 4020 series is a special model having 9 bill compartments with plastic bill clip and no coin compartment 2 CR 621X series is heavy duty metal casing INFERFACE APPLICATION Model Number Interface Security Power Code Source CR 4000 4020 4100 12 24 V Pulse 4210 CR 6210 Erinterdrive NAA Printer CR 4001 4101 4211 Dedicated RS232 serial N A CR 4002 4102 4212 Non dedicated RS232 on 255 12VAC serial Adaptor CR 4003 4103 4213 Parallel 0 255 CR 4004 4104 4214 CR 6214 Dedicated RS232 serial N A 12VDC PC CR 4005 II 4105 II 12VAC 4215 II CR 6215 USB USB PID Adaptor CR 4015 CR 4115 GE USB USB PID USB Port CARTON CONTENTS 1 Cash drawer pre assembled 2 User s manual 3 Separators of bill compartment 4 pcs for CR4000 4 CR4005 II and CR4015 only 4 Key 2 pcs There is a key serial No sticker on the cash drawer bottom plate If user lost the key he she can order the key according to this number 5 Signal Cable depend on model Part 2 a For CR4000 4020 4100 4210 6210 The standard signal cable is d wa