Home

Valcom V-D11025A

image

Contents

1. VA 24019 www valcom com Wiring Information Wiring and Jumper Settings FA Volts 110 Volts Ground 110 Volts TA Volts Jumper Number On Off JP1 12 24 Hour Mode 12 Hour Mode 24 Hour Mode JP2 Brightness Brightest Bright JP3 Loss of Communication Alert 5 Minutes 1 Hour 12 Valcom Inc VALCOM on Roanoke VA 24019 Wiring Information 2 Wire Digital Communication Wiring Information V WMCA Master Clock 18 19 DATA IN V C6124P V CCU 24 volt outputs 24 VDC IN 2Wire Digital je 2 O Sg Gs Output to Clocks ee Se Es v V C6124P and the V CCU are ordered as a V VCU fl A AN 7 A py 7 N 7 NN k 7 ap 5 V A2412 or V A2416 V D2425 or V D2440 CiN Z D 7 N Z V A2412 or V A2416 540 563 2000 P 540 362 9800 F www valcom com Valcom Inc 540 563 2000 P VALCOM 5614 Hollins Road 540 362 9800 F Roanoke VA 24019 www valcom com Support Troubleshooting The clock is not running What do I do a Measure the input voltage to the clock The voltage should measure 85 135 volts in the 110 volt model or 10 28 volts in the 2 5 24 volt model and 16 28 volt in the 4 0 24 volt model b Make sure the transformer is an isolated transformer if using a 24 volt model c Make sure the ground wire is not touching other wires NOTE If you fail to follow instructions a and b listed above the fuses can be blown Clock is only di
2. VALCOM Installation Manual V1 03 V D2425 and V D2440 Digital Clock Valcom Inc 540 563 2000 P 5614 Hollins Road 540 362 9800 F Roanoke VA 24019 www valcom com VALCOM V D2425 and V D2440 Wired Clock Table of Contents Table of Contents 2 Flush Mount Installation 3 Surface Wall Mount Installation 4 Metal Double Mount Installation 5 Plastic Surface Wall Mount Installation 6 Plastic Surface Wall Mount Installation 7 Plastic Double Mount Installation 8 Plastic Double Mount Installation 9 Plastic Double Mount Installation 10 Wiring and Jumper Settings 11 2 Wire Digital Communication Wiring Intormation 12 Troubleshooting 13 Frequently Asked Questions 14 Compliances 15 manuals may change without prior notice Valcom Inc 5614 Hollins Road Roanoke VA 24019 540 563 2000 P 540 362 9800 F www valcom com Valcom Inc 540 563 2000 P VALCOM 5614 Hollins Road 540 362 9800 F Roanoke VA 24019 www valcom com Installation Instructions Flush Mount Installation Dm W Mount the flush mount box into the wall Connect the ground wire into the flush mount box using the tooth lockwasher and the machine screw nut included in the kit Disconnect the red filter from the display panel Connect the wiring as shown on the wiring diagram IMPORTANT If using a low voltage system 24 volt make sure that the transformer is an isolated transformer Mou
3. antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the unit to ensure compliance IC Statement for Canada only This Class B digital apparatus complies with Canadian ICES 003 CET appareil num rique de la classe B est conforme la norme NMB 003 du Canada CE Declaration of Conformity We The Sapling Company certify and declare under our sole responsibility that the SBD 1000 V D2425 and V D2440 conform with the essential requirements of the EMC Directive 2004 108 EC and LVD 2006 95 EC based on the following standards applied EN 55022 2006 EN 61000 3 2 2006 EN 61000 3 3 1995 A1 2001 A2 2005 EN 55024 1998 A1 2001 A2 2003 EN 60950 1 2006 Safety Part 1 16
4. com Installation Instructions Metal Double Mount Installation INNER HOLES OUTER HOLES DIRECT MOUNT DIRECT MOUNT TO TO GANG BOX ie WALL OR CEILING Screw hanger mounting rod included in the kit into the crossbar also included in the kit Insert wires through hanger mounting rod Install crossbar using two 2 6 32 screws into double gang box Mount the double mount box into the clock base using two 2 6 nuts and Tooth Lockwasher 6 The double mount can be mounted either on the wall or on the ceiling Insert the two 2 locking hole plugs 0 187 and the locking hole plug 0 562 into the unused holes Insert double mount case onto the hanger mounting rod Insert the support bracket onto the hanger mounting rod Screw the two 2 nuts included in the kit onto hanger mounting rod and secure the clock base to wall Connect the ground wire into the double mount box using the tooth lockwasher and machine screw nut included in the kit Disconnect the red filter from the display panel Connect the wiring as shown on the wiring diagram IMPORTANT If using a low voltage system 24 volt make sure that the transformer is an isolated transformer Mount the display panel on one side of the double mount box using four 4 black machine screws 6 included in the kit Make sure the switches are on the right side Snap the red filter into the display panel Repeat steps 9 13 for the
5. crew both housings together Using the two 2 self tapping 6 19 x 7 16 screws supplied in the assembly kit screw both back sides of the clock housings together 2 screws per clock O Feed wiring through base and pole Take the wiring coming from the switch box and begin to feed it through the center of the base of the mounting assembly until it emerges from the hole in the center of the clock housing Make sure there is roughly 1 5 2 of wiring coming from the switch box Perform this task for both clocks If installing IP clocks run bare Ethernet wire without an RJ45 connector and install the connector after it has been routed through the clock if possible this will be much easier than running the wire with the connector on If not possible make sure that there is no boot present in order for the connector to fit through the assembly If you are using an Ethernet bracket with the installation of IP clocks the assembly of the clocks in steps 6 and 7 can be accomplished before mounting the assembly to the wall in step 5 making the overall installation more simple instructions continued on next page 10 Valcom Inc 540 563 2000 P VALCOM 5614 Hollins Road 540 362 9800 F Roanoke VA 24019 www valcom com Installation Instructions Plastic Double Mount Installation 6 O Snap and screw base to metal mounting bracket Snap the base to the metal mounting bracket by first making contact with the lip in the upper side
6. d tighten the clamp After securing excess wiring plug the jack at the end of the wiring into the appropriate jack on the back of the display board Mount Display Board to Housing Using the four 4 self tapping 6 19 x 1 2 flat head screws supplied in the assembly kit take the display board and screw it to the front side of the clock housing 4 screws per clock Snap on Filter Take the red filter bezel and snap it on to the front side of the housing Snap on Frame Take the gray frame and snap it on to the front side of the housing Valcom Inc 540 563 2000 P VALCOM 5614 Hollins Road 540 362 9800 F Roanoke VA 24019 www valcom com Installation Instructions Plastic Double Mount Installation Valcom Inc 540 563 2000 P ALCON 5614 Hollins Road 540 362 9800 F Roanoke VA 24019 www valcom com Installation Instructions Plastic Double Mount Installation For metal mounting bracket Use a wall anchor that can support 50 Ibs or more with a maximum screw size of 10 1 5 Install metal mounting bracket First remove the metal mounting bracket from the inside of the double mount base by unscrewing the two 2 6 32 x 1 2 screws located on the underside of the base save these screws for step 5 Next screw the metal mounting bracket to the wall or ceiling in which the clocks are being installed To mount to the switch box screw the four 4 6 32 x 1 screws supplied in the assembly kit through the inner four hol
7. es of the metal mounting bracket Use the outer four holes to mount anchors to the wall both anchors and screws for anchors not supplied in kit For IP clocks if using an Ethernet bracket as shown in the diagram use the two 2 6 32 x 1 4 included in the assembly kit to mount the Ethernet bracket to the metal mounting bracket at this point Ethernet bracket not supplied in assembly kit Note if using a plastic switch box a ground wire must be routed through the switch box and into one 1 of the four 4 metal mounting bracket screws in order to provide ground to the metal mounting bracket Note the metal mounting bracket MUST be secured by both the screws going to the switch box AND the anchors going into the wall 2 Mount clock housings to pole Align the hole in the center each housing with one of the three holes on the mounting pole where the wiring will be routed the installer will chose which hole at the end of the pole to use based on how far they want the clock to sit from the wall Screw from the inside of the housing into the four holes surrounding the hole in the center of the housing using the four 4 8 32 x 7 16 screws supplied in the assembly kit 4 screws per clock securing both housings to the mounting pole Note end caps from one side of each clock must be removed to mount both clocks to the mounting pole Remove one end cap from each clock from the side in which the mounting pole enters the clock S
8. nt the display panel into the flush mount box using the four 4 black machine screws 6 included in the kit Make sure the switches are on the right side Snap the red filter into the display panel Valcom Inc 540 563 2000 P VALCOM 5614 Hollins Road 540 362 9800 F Roanoke VA 24019 www valcom com Installation Instructions Flush Mount Installation Figure 1 6 MIN TO CEILING Flush Mount Picture 4 0 Figure 2 mus I 6 MIN TO CEILING Front view Valcom Inc 540 563 2000 P VALCOM 5614 Hollins Road 540 362 9800 F Roanoke VA 24019 www valcom com Installation Instructions Surface Wall Mount Installation Mm BW N Mount the wall mount box into the double gang box using four machine screws 6 32 included in the kit Connect the ground wire into the flush mount box using the tooth lockwasher and machine screw nut included in the kit Disconnect the red filter from the display panel Connect the wiring as shown on the wiring diagram IMPORTANT If using a low voltage system 24 volt make sure that the transformer is an isolated transformer Mount the display panel into the flush mount box using four 4 black machine screws 6 included in the kit Make sure the switches are on the right side Snap the red filter into the display panel Valcom Inc 540 563 2000 P VALCOM 5614 Hollins Road 540 362 9800 F Roanoke VA 24019 www valcom
9. of the base and the metal mounting bracket When the base has been snapped onto the bracket take the two 2 6 32 x 1 2 pan head screws that orginally came installed on the base and screw them back into the two holes on the underside of the base to secure the base to the metal mounting bracket Connect switch box wires to clock harness Take the wiring harness supplied with the clock and make all necessary connections between the wiring harness and the switch box wires using wire nuts Perform this task for both clocks If using IP clocks wiring will not be supplied with the clocks the installer will be responsible for supplying all Ethernet wiring Plug and secure wiring Loosen and slip excess wiring through provided wire clamp comes attached to each housing and tighten the clamp After securing excess wiring plug the jack at the end of the wiring harness into the appropriate jack on the back of the display board Perform this task for both clocks Mount display board to housing Using the four 4 self tapping 6 19 x 1 2 flat head screws supplied in the assembly kit take the display board and screw it to the front side of the clock housing 4 screws per clock Snap on filter Take the red filter bezel and snap it on to the front side of each clock housing Snap on frame Take the gray frame and snap it on to the front side of each clock housing Valcom Inc 540 563 2000 P VALCOM 5614 Hollins Road 540 362 9800 F Roanoke
10. second clock Valcom Inc 540 563 2000 P VALCOM 5614 Hollins Road 540 362 9800 F Roanoke VA 24019 www valcom com Installation Instructions Plastic Surface Wall Mount Installation Valcom Inc 540 563 2000 P VALCOM 5614 Hollins Road 540 362 9800 F Roanoke VA 24019 www valcom com Installation Instructions Plastic Surface Wall Mount Installation Mount Housing to Wall and or Gang Box To mount the housing to the wall drive two 2 plastic anchors into the wall not Q supplied in kit and take two pan head screws also not supplied in kit and drive them into the plastic inserts leaving an 1 8th inch gap between the head of the screw and the wall Mount the housing to the wall by lining up the two holes in the back of the top of the housing with the two screws with the 1 8 inch gap from the wall and slide the housing onto the heads of the screws To mount the housing to the gang box take the four 4 6 32 x 1 screws supplied in kit and screw them through the four holes in the center of the inside of the housing and the four holes in the gang box Note If using a metal gang box a ground must be provided to the gang box Feed Wiring Into the Housing Take the wire coming from the inside of the gang box and feed it through the hole in the middle of the housing Plug and Secure Wiring Loosen the provided wire clamp comes attached to the inside of the housing and slip excess wiring through an
11. splaying dashes What do I do This means that the clock is receiving power but not receiving a time correction signal a Confirm that the head end is sending data to the clock power supply b Confirm that clock power supply is wired correctly The clock is displaying a time but the colons are flashing What does this mean This means that the clock at one point has received a time update but since then the correction has been lost a Confirm that the head end is sending data to the clock power supply b Check to see that all wiring is correctly 14 Valcom Inc 540 563 2000 P VALCOM 5614 Hollins Road 540 362 9800 F Roanoke VA 24019 www valcom com Support Frequently Asked Questions Can the digital clock be used as an independent clock No the V D2425 and V D2440 digital clock requires a communication input and must be used with either a master clock or a V D11025A or V D11040A digital clock Some clocks require a 9 volt battery backup for timekeeping What happens to the V D2524 or V D2540 if a power failure occurs Upon restoration of power the clock immediately receives a correction signal from the master clock and resets itself to display the correct time This occurs within seconds of power up so no battery backup is required for a timekeeping base within the individual clocks Since the clock does not require a battery backup the clock never needs to be opened How can interface the V D2524 or V D2540 with Ra
12. uland Dukane and other systems The V WMCA Master Clock or the V D11025A or V D11040A digital clock can be used as an interface between other systems and V D2524 or V D2540 clocks What happens if voltage on the power line drops from 24 VAC to lower voltage The clock will still function and will maintain the same level of brightness However the current consumption will increase proportionally to the decrease in voltage 13 Valcom Inc 540 563 2000 P VALCOM 5614 Hollins Road 540 362 9800 F Roanoke VA 24019 www valcom com Compliances C QD FCC Part 15b Industry Canada FCC Statement Information to the user for U S only This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving