Home
AMX NXD-500iW-MB
Contents
1. af EFA For more detailed installation configuration programming file transfer and operating instructions refer to the NXD 500i Operation Reference Guide available online at www amx com STATE UNIVERSITY ee Microphone Touch screen _ I B Front Bezel Button oa FIG 1 NXD 500IW MW 5 Modero Widescreen WallMount Touch Panel Overview The NXD 500IW widescreen color panel is designed for use in high humidity INDOOR environments ranging between 50 and 95 relative humidity It includes a built in microphone speakers a mini USB port for programming and audio output and one NetLinx programmable button All power is supplied via Power Over Ethernet PoE utilizing a PS POE AF PoE Injector FG423 80 or equivalent PoE device The NXD 500IW comes in Mystique black NXD 500IW MB FG2261 09 and Mystique white NXD 500IW MW FG2261 12 The NXD 500IW supports Intercom functionality which allows two communicating panels controlled by the NetLinx Master to transmit full duplex audio signals over a network in order to be used as an Intercom system Specifications NXD 500IW FG2261 09 12 Specifications Dimensions HWD NXD 500IW with bezel 4 15 x 5 59 x 1 97 10 50 cm x 14 20 cm x 5 cm e CB TP5 Rough In Wallbox optional 4 27 x 5 14 x 3 40 10 86 cm x 13 06 cm x 8 64 cm Power e PoE Powered No local Power Supply needed Requirements e Max power draw 5 5W Memory Fact
2. 500IW Installation Guide 93 2261 09 Accessories Other AMX e CB TP5i Rough In Wallbox FG038 11 Equipment e Back Cover for the CB TP5i Rough In Wallbox FG038 12 e PS POE AF PoE Injector FG423 80 e CC USB Type A to Mini B 5 wire programming cable FG10 5965 e USB to Headphone Adaptor FG5966 23 Operating Storage Environments IP Rating Compliance Indoor Use Only The NXD 500IW is IP Rating 51 compliant Ingress of dust is not entirely prevented but it will not enter in sufficient quantity to interfere with the satisfactory operation of the device complete protection against contact Dripping water vertically falling drops shall have no harmful effect Panel Connectors and Wiring FIG 2 shows the connectors located on the NXD 500IW Modero panel The mini USB port is used both for programming the touch panel and for audio output The mini USB port automatically detects the presence of a headphone adaptor allowing the port to be used for headphone connectivity Ethernet 10 100 port Mini USB port Back box FIG 2 Connector layout on the NXD 500IW For more information on connection and use of the Panel Connectors as well as information on programming and headphone connectivity please refer to the NXD 500i Operation Reference Guide available at www amx com Front Bezel Button The NXD 500IW has only one button on the front of the device in the center of the bezel This button has several uses e Press the
3. FIG 7 designed to attach the panel to most standard wall materials This backbox has a locking tab on three of the four faces missing only on the face containing the space for the connections to help lock the backbox to the wall These locking tabs are only extended AFTER the backbox is inserted into the wall WARNING When installing the backbox make sure that the assembly is in the correct position and in the correct place Once the locking tabs are extended and locked into place removing the backbox may be difficult without having access to the back of the wall or causing damage to the wall Note In order to guarantee a stable installation of the NXD 500IW the thickness of the wall material must be a minimum of 50 inches 1 27cm and a maximum of 875 inches 2 22cm WARNING The maximum recommended torque to screw in the locking tabs on the plastic back box is 5 IN LB 56 N CM Applying excessive torque while tightening the tab screws such as with powered screwdrivers can strip out the locking tabs or damage the plastic back box 1 Prepare the area by removing any screws or nails from the drywall before beginning the cutout process 2 Cutout the surface for the back box Refer to the dimensions in the NXCD 500 Operation Reference Guide available from www amx com for more information For full warranty information refer to the AMX Instruction Manual s associated with your Product s 1 11 CAUTION Making sure
4. NXD 500IW Specifications Cont Front Panel Components Cont Microphone e Frequency response of 300 to 3400Hz used for intercom applications Speaker e Output of 40hm 2 Watts with a 300HZz low cutoff frequency Side Panel Connectors Ethernet 10 100 Port e RJ 45 port for 10 100 Mbps communication The Ethernet port automatically negotiates the connection speed 10 Mbps or 100 Mbps and whether to use half duplex or full duplex mode Power is supplied through Power Over Internet PoE NXD 500IW panels communicate with the NetLinx Master using the ICSP protocol over Ethernet LEDs show communication activity connections speeds and mode information L A link activity Yellow LED lights On when the Ethernet cables are connected and terminated correctly and then blinks when receiving Ethernet data packets SPD speed Green LED lights On when the connection speed is 100 Mbps and turns Off when the speed is 10 Mbps Mini USB Connector e 5 pin Mini USB connector used for programming firmware update and touch panel file transfer between the PC and the target panel The connector is also used for providing audio output for external speakers e Operating Temperature 0 C 32 F to 40 C 104 F e Operating Humidity 5 95 relative humidity non condensing e Storage Temperature 20 C 4 F to 60 C 140 F e Storage Humidity 5 85 RH e Indoor Installation and Operation ONLY Included e NXD
5. button once to start a previously programmed function or to turn off the display if not previously programmed e Press and hold the button for 6 seconds to put the device into Setup Mode e Press and hold the button for 9 seconds to enter Calibration Mode e Press and hold the button for 20 seconds to reboot the panel NXD 500IW Setup and System Connection 1 Carefully remove the panel from the shipping box peel the protective plastic cover from the LCD and apply power to the panel via the PoE Injector 2 From below the LCD press the Front Bezel button for 9 seconds passing over the Setup page to access the Calibration setup page and follow the on screen instructions to return to the main Setup page 3 Press the on screen Protected Setup button on the Setup page 4 Enter the panel password into the on screen keypad default is 1988 5 Press the Device Number field to open the on screen Device Number keypad and enter a value for the panel default is 32001 6 Press the System Connection button to open the System Connection page 7 Toggle the DHCP Static field to DHCP 8 Toggle the Type field to Ethernet 9 Toggle the Mode field to URL 10 Enter both the System Number and IP Address of the target Master 11 Enter a valid Username and Password if the target Master is secured 12 Press the Back button and then press the on screen Reboot button to save any changes and cycle power to the panel Installation of the NXD 50
6. that the actual cutout opening be slightly smaller than the provided dimensions is highly recommended This action provides the installer with a margin for error if the opening needs to be expanded Too little wall material removed is always better than too much 3 Remove the bezel from the NXD 500IW 4 Gently unscrew the two screws attaching the NXD 500IW to its back box These are at the bottom of the device underneath the touch screen Carefully remove the NXD 500IW from the back box NOTE While the screws are loosened you can adjust the LCD to ensure that it is parallel to the sides of the backbox if necessary While adjusting the LCD is possible it is not required in most cases 5 Thread the incoming Ethernet and mini USB wiring if mini USB access is desired from their terminal locations through the surface opening Leave enough slack in the wiring to accommodate any re positioning of the panel 6 Push the back box into the wall opening Insure that the locking tabs lie flush against the back box T Extend the locking tabs on the sides of the back box by tightening the screws inside the box until snug Not all of the tabs must be extended to lock the back box in place but extending a minimum of the top and bottom tabs is highly recommended Apply enough pressure to the screw head to keep the box flush with the wall this ensures that the locking tabs will tighten up against the inside of the wall The back box is clear
7. to allow visual confirmation that the tabs have been extended and are gripping the wall as well as in assisting with removal if necessary 8 Insert both connectors into their corresponding locations along the left side of the NXD 500IW touch panel 9 Test the incoming wiring by attaching the panel connections to their terminal locations and applying power via the PoE Injector Verify that the panel is receiving power and functioning properly to prevent repetition of the installation NOTE Do not disconnect the connectors from the touch panel The unit must be installed with the attached connectors before being inserted into the drywall 10 Insert the NXD 500IW back into the back box 11 The microphone cable is taped to the back box Connect the microphone cable to its connector making sure that the cable does not interfere with reattachment of the bezel 12 Carefully replace the two Plastite screws holding the device to the back box 13 Place the bezel Trim Ring assembly back onto the device Make sure to align the Microphone Light and PIR Motion sensor locations to their respective openings on the bezel 14 Reconnect the terminal Ethernet and USB to their respective locations on either the Ethernet port or NetLinx Master Installing the NXD 500IW into a Flat Surface using 4 screws Three 4 mounting screws not included are secured through circular holes located at the left and right sides of the NXD 500IW The most import
8. 0IW For more information on the installation of the NXD 500IW please refer to the NXD 500i Operation Reference Guide available at www amx com The NXD 500IW is contained within a clear outer housing known as the back box FIG 3 This back box is removed when installing the device into a wall or into a Rough In Box Locking tab screws Locking tabs Closed Locking tabs Open FIG 3 NXD 500IW backbox with closed and open locking tabs Removing the Bezel In certain circumstances the bezel must be removed Because the device is installed against a wall the bezel must be removed carefully to prevent the two top prongs from being broken To remove the bezel 1 Gently lift up on the bezel from the bottom Do NOT pull up from the sides or the top 2 Let the bezel fall forward from the top of the device and let it pivot from the bot tom 3 Remove the bezel from the two bottom prongs 4 When reattaching the bezel to the device make sure to align the Microphone Light and PIR Motion sensor locations on the device to their respective openings on the bezel assembly NOTE Do not remove the gasket on the underside of the bezel If the gasket should accidentally detach itself gently reinsert it in the gasket channel running around the center hole in the bezel Do NOT stretch the gasket while reinserting it Installing the NXD 500IW into a wall Unlike most AMX touchpanels the NXD 500IW comes with a clear plastic backbox
9. ant thing to remember when mounting the NXD 500IW is that the outer frame Mounting Tabs must be installed flush against the mounting surface e Refer to SP 2261 02 for detailed installation dimensions e Cutting out the surface slightly smaller than what is outlined in the installation drawings in order to make any necessary cutout adjustments is highly recommended 1 Prepare the area by removing any screws or nails from the surface before beginning the cutout process 2 Cut out the surface for the NXD 500IW 3 Remove the bezel from the NXD 500IW 4 Gently unscrew the lower right hand screw attaching the NXD 500IW to its back box These are at the bottom of the device underneath the touch screen Gently remove the NXD 500IW from the back box 5 Thread the incoming Ethernet and USB wiring from their terminal sources through the surface opening Leave enough slack in the wiring to accommodate any re positioning of the panel 6 Connect the Ethernet and USB connectors to their corresponding locations along the left side of the un powered NXD 500IW touch panel The USB connectors can be from either a USB extension cable or a wireless USB RF transmitter NOTE Do not disconnect the connectors from the touch panel The unit must be installed with the necessary connectors before being inserted into the solid surface T Carefully slide the main unit into the cutout until the Mounting Tabs of the NXD 500i lie flush against the wall 8 In
10. ory e 128 MB SDRAM default 256 MB integrated Flash Memory not upgradeable factory programmed Certifications e FCC Part 15 Class B e CE e IEC 60950 e RoHS Panel LCD Parameters e Aspect ratio 16 x 9 e Maximum brightness luminance 200 cd m2 e Channel transparency 8 bit Alpha blending e Contrast ratio 250 1 e Display colors 256 thousand colors 18 bit color depth e Dot pixel pitch 0 14 mm e Panel type TFT Color Active Matrix e Screen resolution 800 x 480 pixels HV 60 Hz frame frequency e Viewing dimensions 4 3 x 2 58 109 2 mm x 65 2 mm e 4 25 x 2 55 10 80cm x 6 48cm Viewing Angles e Up Down Left Right 85 85 85 85 IR Reception Angle Horizontal 25 left and right from center e Vertical 15 up and down from center Sample Rates Supported Audio e 48000Hz 44100Hz 32000Hz 24000Hz 22050Hz 16000HZz 12000Hz 11025Hz and 8000Hz e Full duplex VoIP capabilities Front Panel Components Intercom Light Sensor e Photosensitive light detector for automatic adjustment of the panel brightness Motion Sensor PIR e Proximity Infrared Detector to wake the panel when panel is approached Front Bezel Button Provides both access to the Setup and Calibration pages and toggles the panel between a sleep or wake state This button is also user programmable Installation Guide NXD 500 IW 5 Water Resistant Wall Flush Mount Touch Panel
11. sert and secure three 4 Mounting Screws not included into the corresponding holes located along the sides of the NXD 500IW using a grounded Phillips head screwdriver until the unit is secure and flush against the wall 9 The microphone cable is taped to the back box Connect the microphone cable to its connector making sure that the cable does not interfere with reattachment of the bezel 10 Carefully replace the two Plastite screws holding the device to the back box 11 Place the bezel back onto the device Make sure to align the Microphone Light and PIR Motion sensor locations to their respective openings on the bezel 12 Reconnect the terminal Ethernet and USB to their respective locations on either the Ethernet port or NetLinx Master 93 2261 09 REV A 2011 AMX All rights reserved AMX and the AMX logo are registered trademarks of AMX AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 800 222 0193 fax 469 624 7153 technical support 800 932 6993 www amx com amt Lr