Home
Eminent EM6514 remote power controller
Contents
1. e EM6514 e Domotica Wall Switch Sensor e Manual 2 0 Using the sensor In the following figure you can see one of the most common situations to use an EM6514 Wall Switch Sensor in combination with the EM6556 Mini Switch By using the EM6556 Mini Switch sold separately not included you are able to use your existing wall switch to activate a scene at your own desire 1 EM6514 EM6556 Figure 1 EM6514 Wall Switch Sensor EM6556 Mini Switch 2 1 Use case example Switching hall and or ceiling light If your hall light or ceiling light can be controlled by using a wall switch you can use EM6514 Wall Switch Sensor and EM6556 Mini Switch to update the normal situation for the home automated situation The benefits of doing this e Automatically enabling the light when you enter your house for example when using the alarm system e Automatically enabling the light on a smoke alarm to find your way out of your house e Automatically enabling the light on a burglary alarm to scare off intruders And you are still able to control the light manually using your existing wall switch 4 ENGLISH 2 2 Use case example Change your living room into the right ambience Want to set your room into the right ambience No problem Use an EM6514 Wall Switch Sensor in your living room to trigger your self defined scene For example this scene can power up your TV dim the lights near the TV and switch off other lights in your
2. room The benefits of doing this Using your existing wall switch to enable more devices instead of only a ceiling light Reduce energy consumption by disabling several devices and lights using the same existing wall switch sensor e Getin the right mood with one click instead of switching on off other devices and lights manually 3 0 Installing the sensor 3 1 Installing the wall switch sensor into a wall switch box Take the sensor out of the packaging Open the wall switch box where you want to install the sensor Check if the power is really switched off for example by using a voltage tester Disconnect the neutral wire and live wire from the sensor Connect the dry contact cables white to the wall switch Connect the blue neutral wire of the mains with a N input of the sensor and tighten the screw 7 Connect the 230v live wire of the mains with the L input of the sensor Often this wire has a brown color 8 Make sure all wires are fully inserted into the sensor 9 Turn on the main switch to enable the mains again Ore ONS 11 5 ENGLISH Test whether the device works by pressing the button on the sensor Be careful and avoid touching the wires The LED on the sensor will be lit The connected device will also be turned on Do not close the junction box yet 3 2 Assigning the sensor to the e Domotica e Centre There are two situations possible when assigning the sensor to the e Centre if You ass
3. I EMINENT e DOMOTICA MANUAL EM6514 e Domotica Wall Switch Sensor WWW EMINENT ONLINE COM 2 ENGLISH EM6514 e Domotica Wall Switch Sensor Table of contents MO IMtrOGUCHION 22 22 hc2c Seed et headin ede eeestier tains dives Acasa niet decent artis 2 1 1 Functions and features aissis iE e ETE Na dani 2 1 2 PackiNg CONTSMIS ii seve ceceec cen seecesceesiescag ccvasecaexsuseas stan dacesten ccag i aaa tagidagi 3 2 0 Using the SENSOM ivcistise eedievecse vice ivveveis eani diari eaaa aa aE panaia Ea Eai iiai 3 2 1 Use case example Switching hall and or ceiling light eeeeeeeeeeeeeeeene 3 2 2 Use case example Change your living room into the right ambience 4 3 0 Installing the SENSO sirieias anedig vaginas dadan asaan 4 3 1 Installing the wall switch sensor into a wall switch DOX ceeeeeeeeeeeeteeeeeeees 4 3 2 Assigning the sensor to the e Domotica Centre cccccecceseeeeeeeeeeeeeeeeeeees 5 3 3 Adding the sensor to the already installed e Domotica e Centre 0 0 5 4 0 Removing the SCNSOM scceeceesceseeeeeneeeeeeseaeeeeeseaeesseeeeaeeesaeeeaeessaeseseessaeeeaeeeeaees 6 5 0 Frequently Asked QueSTIONS eceecceeeceeeeeeeeeeeereseaeeseeeeaeetaeseaeesaeeeaeeseneeeeerentes 6 6 0 Service ANd SUPPOFT eee eee ceeneeeeeeeeeeeeeeeneeeaeeteeeeaeeseeeeaeeseaeeeaeessaeeteeeseaeeeneeeeaees 8 7 0 Warning and points Of attention ee eeeeeeeeeeeeeene
4. econd hand Eminent product the remaining period of warranty is measured from the moment of purchase by the product s first owner The Eminent warranty applies to all Eminent products and parts inextricably connected to and or mounted on the main product Power supply adapters batteries antennas and all other products not integrated in or directly connected to the main product and or products of which without reasonable doubt can be assumed that wear and tear show a different pattern than the main product are not covered by the Eminent warranty Products are not covered by the Eminent warranty when subjected to incorrect improper use external influences and or when opened by parties other than Eminent 10 ENGLISH 9 0 Declaration of Conformity To ensure your safety and compliance of the product with the directives and laws created by the European Commission you can obtain a copy of the Declaration of Conformity concerning your product by sending an e mail message to info eminent online com You can also send a letter to Eminent Computer Supplies P O Box 276 6160 AG Geleen The Netherlands Clearly state Declaration of Conformity and the article code of the product of which you would like to obtain a copy of the Declaration of Conformity The information contained in this document e DOMOTICA has been created with the utmost care No le gal rights can be derived from these contents Eminent cannot be held responsible nor
5. eeeeeeeaeeseeeeeaeeseaeeseeseaeeenneeeaees 8 8 0 Warranty conditions ee cece eeeeceeeeeeeeeeeeeeeeeeaeeeeeeseaeeseeeeaeesseeesaeesaeeteeeseaeeeaneeeaees 9 9 0 Declaration of Conformity 0 0 ceeeeceeeeeeeeeeeeeeeeeeeeeneeeeeeeeeeseaeeseeeeaeeseeeseeeenaeeeneeees 10 1 0 Introduction Congratulations with the purchase of this high quality Eminent product This product has undergone extensive testing by Eminent s technical experts Should you experience any problems with this product you are covered by a five year Eminent warranty Please keep this manual and the receipt in a safe place 1 1 Functions and features The wireless Z Wave enabled EM6514 e Domotica Wall Switch Sensor allows you to turn on and turn off your illumination and other electrical devices in a room In combination with the e Domotica e Centre you can save a lot on your electricity account and reduce the amount of stand by consumption You will not only save money but you will also protect the environment by using the EM6514 The sensor can be installed behind almost any existing wall switch and therefore can be used throughout your entire house The sensor can also act as a repeater by picking up the wireless signal of other e Domotica devices and broadcast this signal forward This way you can make sure your entire house is provided with the comfort the EM6514 delivers 3 ENGLISH 1 2 Packing contents The following parts need to be present in the packing
6. ign the sensor to the e Domotica e Centre during the installation process of the e Centre itself The installation wizard of the e Centre will move along several steps during the installation process of the e Centre itself meaning you can add all your e Domotica devices through the e Centre s own website http ecentre For this installation you have to follow the steps shown on screen You can add your sensor to the already installed e Centre This is described in the next chapter 3 3 Adding the sensor to the already installed e Domotica e Centre 1 2 3 xo w Make sure your computer is completely started Open your computer s web browser Fill in http ecentre in the address bar of your web browser and press the Enter key on your keyboard The webpage of the e Centre will be shown If the Wizard is started click Exit Wizard to go to the e Domotica Products page Click the Include button The e Centre will start to search for new e Domotica devices Press the button on your new sensor three times A message will appear Product found Give the connected and found device a name choose a location and click Save The sensor has now been added to the e Centre The e Centre will now be able to read the sensor 6 ENGLISH 10 You can now put the sensor in the wall switch box We suggest to disable the mains by turning off the main switch of the house when putting the se
7. liable for the information contained in this document Trademarks all brand names are trademarks and or registered trademarks of their respec tive holders Eminent is a member of the Intronics Group EM6514 03 2012
8. nsor in the wall switch box 4 0 Removing the sensor In some cases it might be necessary to remove exclude the sensor from your e Centre Follow these instructions to do so 1 Make sure your computer is completely started 2 Open you computer s web browser 3 Fill in http eCentre in the address bar of your web browser and press the Enter key on your keyboard 4 The openings screen of the Eminent e Centre will be shown If the Installation Wizard starts click Exit Wizard to continue 5 Click the Exclude button Press the button on your sensor three times 7 The device has now been deleted a message will appear to confirm this D 5 0 Frequently Asked Questions Q cannot open http ecentre using my internet browser A Go to your e Centre touchscreen and press Devices press Settings and check if your e Centre has received an IP address wired or wireless If not check the settings of your e Centre using a network cable If yes open the page using the IP address For example if the IP address on screen is 192 168 1 30 you can enter this address in the address bar of your browser like this http 192 168 1 30 Press Enter on your keyboard to open the page Q What is the maximum wireless range of my e Domotica devices A Thanks to the network s repeating option amplifiers the wireless range of the e Domotica devices is virtually unlimited Both the EM6514 senso
9. r and the EM6556 mini switch act as a repeater Without repeating the maximum wireless range indoor is approximately 15 meters You can optimize the wireless range by adding an extra EM6556 mini switch EM6550 switch or EM6551 dimmer and then use the Optimize function in the e Centre s webpage Q What kind of LED indications does the sensor have A The sensor is not included to a system out of the box The LED will flash on and off at 2 second intervals Once the sensor is included to a system the LED will be off when the sensor is turned off and lit when the sensor is turned on by pressing on the button When a overload state occurs and the sensor is ON the LED will flash on and off at 0 5 second intervals The on off button is disabled in this state The overload state can be cleared by disconnecting and reconnecting the wiring Q 7 ENGLISH How do include or exclude the sensor into a different Z wave controller Inclusion Have your Z wave Controller entered inclusion mode press the On off button of the sensor three times Exclusion Have your Z wave Controller entered inclusion mode press the On off button of the mini switch three times Once the node has been included the LED will go into an interval of two seconds on and two seconds off Reset Press the On Off button three times to enter inclusion mode Within one second press On Off button again until LED is off The home ID and node ID will be cleared and rese
10. t to factory default Association Have a Z wave remote module entered in association mode first Press link button three times within 1 5 seconds to enter association mode The LED will blink for 0 5 sec and then go off Configuration Basic Set Level The Basic Set Command is sent with value to have the receiving device recognize the value for controlled level for example if the Basic Set Command sent to dimmer with value the dimmer would activate the luminance according to the value for example 0 Off 1 99 On Binary Switch Device Dim Level Multilevel Switch Device Configuration command Function Basic Set Level Parameter number 1 Size 1 Range 0 99 Default 99 Configuration Amount of Delay seconds This is applied to determine the delay time setting to send the Basic Set Off command when the manual switch input at NO open Example 0 immediately Off 1 127 delay 1 127 second to Off Configuration command Function Amount of delay Parameter number 2 Size 1 Range 0 127 Default 1 8 ENGLISH 6 0 Service and support This users manual has been carefully written by Eminent s technical experts If you have problems installing or using the product please fill out the support form at the website www eminent online com support You can also contact us by phone Below you will find a list with phone numbers for each supported country Country Phone number Rate per minute Belgium Du
11. tch 070 277 286 0 30 Belgium French 070 277 286 0 30 Denmark 45 69918565 Local Costs Finland 35 8942415826 Local Costs Germany 1805 982 234 0 14 Italy 39 0240042016 Local Costs Norway 47 21075033 Local Costs Spain 807 080 042 0 41 Sweden 46 840 309985 Local Costs The Netherlands 0900 3646368 0 45 UK 905 871 0013 0 30 Rates mentioned in this table do not include cell phone charges 7 0 Warning and points of attention Due to laws directives and regulations set out by the European parliament some wireless devices could be subject to limitations concerning its use in certain European member states In certain European member states the use of such devices could be prohibited Contact your local government for more information about this limitations Always follow up the instructions in the manual especially where it concerns devices which need to be assembled Warning In most cases this concerns an electronic device Wrong improper use may lead to severe injuries Repairing of the device should be done by qualified Eminent staff The warranty immediately voids when products have undergone self repair and or by misuse For extended warranty conditions please visit our website at www eminent online com warranty 9 ENGLISH 8 0 Warranty conditions The five year Eminent warranty applies to all Eminent products unless mentioned otherwise before or during the moment of purchase When having bought a s
Download Pdf Manuals
Related Search
Related Contents
WiseScript Editor Reference - SymWISE Support Site Maintenance Lugar de fabricación y embalaje Modo de empleo Ventajas Anamorphic Lens with Lens Changer Unit P7000 Guide de pose Terrasse Monacor PAK-15DMP La belle endormie s`est réveillée POS Solution User Guide Interprofessionnalité et Intégration 5 - HES Copyright © All rights reserved.