Home
AMX HPX-600
Contents
1. e For terminations for which the far end of the cable is not accessible either because the cable has been run under carpet in a conduit or structure or is otherwise fixed the cable must be placed through the cutout in the table prior to installation as indicated in FIG 5 HPX Base Assembly Mounting Surface FIG 5 Inserting the Modules into the Assembly 4 Insert the HPX Modules Note the orientation of each HPX Module a small tab exists on one side of the faceplate of each module Ensure all tabs are facing the same direction see FIG 5 1 Remove one end cap of the HPX Base Assembly by removing the six sheet metal screws and one pivot screw and pivot pawl assembly 2 Slide the pre terminate modules one at a time into the HPX Base Assembly 3 Rout the cables from each module out the bottom of the HPX Base Assembly 4 Use cable ties and one or more of the sliding clips to secure the cables as needed to the HPX Base Assembly 5 Reinstall the end cap of the HPX Base Assembly by installing the six sheet metal screws and one pivot screw and pivot pawl assembly Note Do not over tighten the pivot pawl screw i e do not use a high powered drill to tighten this screw page 3 of 4
2. HPX 600 Holds up to 6 HPX Modules 7 64 194 mm 1 Carefully measure the tabletop or other mounting surface to locate the desired position of the HPX Base Assembly 2 Use the cutout template supplied with the HPX Base Assembly to mark the edges of the cutout Note that very little clearance exists between the HPX Base Assembly and the hole cutout in the mounting surface e Take care to align the cutout carefully with the edges or other appropriate features in the table or mounting surface e If the cutout is misaligned the installed unit will be misaligned e Take care to ensure that the top surface of the mounting surface is not damaged beyond the width of the trim bezel as the cutout is made e Use an appropriate drill and drill bit to make a starting hole within the boundary of the cutout Use an appropriate saw such as a jigsaw to finish the cutout e Make sure cutting tool used is appropriate for the material to be cut and will not tear or chip the top surface e Note that the process of making the cutout will create substantial dust and prepare the environment appropriately 3 Prepare the Terminations Some modules that are included in the final system require some type of backside termination Note Refer to the installation guide for each module to determine the required backside termination e The backside termination for each module can and should be completed before the module is installed into HPX Base Assembly
3. with Stereo Module with Integrated Cables HPX AV101 RGB A FG552 21 RGB with Stereo Module with Integrated Cables HPX C5400 CS A FG552 50 BL K Composite with Stereo UPX Cat5 Kit with HPX Carrier Module HPX C5400 VGA A FG552 51 BL K RGBHV with Stereo UPX Cat5 Kit with HPX Carrier Module HPX C5400 CN A FG552 52 BL K Component with Stereo UPX Cat5 Kit with HPX Carrier Module Power Outlet EU Module page 1 of 4 Installation of the HPX Base Assembly The following sections describe the preparation installation and setup of the HPX 600 900 1200 Hydraport Base Assembly A typical installation will include several various HPX modules see Compatible HPX Modules and Panels above Each HPX module has specific instructions for terminating their connections Refer to each HPX Module s Installation Guide during the installation of the Hydraport system Note Read these instructions in their entirety before beginning the installation The installation requires specific steps to be performed in specific order CAUTION This installation requires specific woodworking skills This installation should be performed by an experienced person comfortable with these types of woodworking operations Improper installation may result in damage to the mounting surface AMX is not responsible for damage caused by improper installation 1 Select a Suitable Location for the HPX Base Assembly The following figures indicate the space req
4. 5 Install the System Into The Mounting Surface 1 Install the unit into the cutout in the mounting surface e Make sure that all cables from the backside terminations pass through the cutout e For terminations for which the far end of the cable is not accessible either because the cable has been run under carpet in a conduit or structure or is otherwise fixed the cable must be placed through the cutout in the table prior to installation as indicated in FIG 5 2 Open the door and rotate the four mounting screws located inside and at each end of the HPX base assembly in order to rotate the retaining tabs out under the mounting surface Note Make sure that the retaining tabs are down and folded out of the way prior to installing the unit in the mounting surface 3 Continue to tighten the mounting screws until the mounting tabs contact the backside of the mounting surface to retain the HPX Assembly FIG 6 MOUNTING SCREWS 4PLACES LID SHOWN TRANSPARENT FOR CLAIRITY MOUNTING TAB ENDCAP SHOWN DIMMED SHOWN TIGHTENED FOR CLAIRITY MOUNTING TAB SHOWN LOOSE END VIEW FIG 6 Mounting Screws amp Mounting Tabs Note For surfaces less than 19mm thick use the supplied plastic spacers by fixing them to each end of the cutout using the supplied double sided tape FIG 7 OPTIONAL SPACER 2PLACES LOCKS IN TIGHT POSITION FIG 7 Optional spacer and mounting tabs deployed page 4 of 4 6 Install th
5. FG560 xx cc are built to accommodate the diverse connection needs of conference and meeting room visitors The HPX 600 900 1200 is designed to be mounted into a horizontal surface such as a conference room table or lectern in order to provide connectivity for power networking Audio Video and control Specific connectivity is accomplished by populating the HPX Base Assembly with various modules FIG 1 HPX 600 900 1200 Hydraport Base Assembly AMX offers 6 versions of the HPX 600 900 1200 Hydraport Base Assemblies with a variety of compatible modules HPX 600 900 1200 Hydraport Base Assemblies HPX 600 BL FG560 01 BL Hydraport Base Assembly 6M Capacity Black Trim HPX 600 SL FG560 01 SL Hydraport Base Assembly 6M Capacity Silver Trim HPX 900 BL FG560 02 BL Hydraport Base Assembly 9M Capacity Black Trim HPX 900 SL FG560 02 SL Hydraport Base Assembly 9M Capacity Silver Trim HPX 1200 BL FG560 03 BL Hydraport Base Assembly 12M Capacity Black Trim HPX 1200 SL FG560 03 SL Hydraport Base Assembly 12M Capacity Silver Trim ATTENTION Only a professional AMX qualified installer should perform this installation Installation must conform to all local codes This product may not be installed by the end user Product Specifications HPX 600 900 1200 Specifications Number of Modules Module sizes are provided in HydraPort units Supported Modules range in size from 1 2 to 4 1 2 HydraPort units HPX 600 six 6 s
6. e System Into the Mounting Surface 1 Terminate the backside connections as required for each cable exiting the HPX system 2 Secure these cables and the power cable to either of the end caps using the supplied wire ties FIG 8 SECURE CABLE USING WIRE TIE FIG 8 Bottom view with cables exiting and secured 3 Secure the cables in at least one additional location after they have been secured to the system so as to prevent undue stress on the system if the cables are inadvertently kicked snagged or pulled Note The socket outlet Connection to Mains Power branch circuit shall be installed near the equipment and shall be easily accessible Additional Documentation For more detailed installation instructions with additional drawings please refer to the HPX 600 900 1 200 Installation Guide available to view or download from www amx com For full warranty information refer to the AMX Instruction Manual s associated with your Product s 93 0560 01 REV B 4 12 2012 AMX All rights reserved AMX and the AMX logo are registered trademarks of AMX AMX reserves the right to alter specifications without notice at any time 3000 RESEARCH DRIVE RICHARDSON TX 75082 800 222 0193 fax 469 624 7153 technical support 800 932 6993 www amx com Bl Fak Dawes Installation Guide wi EP H PX 600 900 1 200 6 9 and 12 Module Connection Ports Overview The HPX 600 900 1200 family of HydraPort Connection Ports
7. ingle space modules HPX 900 nine 9 single space modules HPX 1200 twelve 12 single space modules Enclosure Black anodized metal frame with matte black plastic end caps HPX 600 900 1200 BL FG560 xx BL Clear anodized metal frame with matte black plastic end caps HPX 600 900 1200 SL FG560 xx SL Matte black module face plates on all I O modules Optional Accessories Compatible HPX Modules and Panels see below Dimensions HWD Max above mounting 0 31 7mm with lid open surface e 0 13 3mm with lid closed Max below mounting 6 94 175 mm surface Mounting surface HPX 600 8 19 x 5 44 208mm x 138mm footprint HPX 900 11 16 x 5 44 283mm x 138mm HPX 1200 14 09 x 5 44 358mm x 138mm Min mounting Min 0 75 19mm surface thickness Max 2 0 51 mm Table Cutout HPX 600 7 64 x 4 84 194mm x 123mm Dimensions HPX 900 10 59 x 4 84 269mm x 123mm HPX 1200 13 54 x 4 84 344mm x 123mm Base Assembly only HPX 600 1 8lbs 0 82Kg e HPX 900 2 4lbs 1 1Kg e HPX 1200 2 8lbs 1 3Kg Typical Installation e HPX 600 2 6lbs 1 2Kg e HPX 900 3 3lbs 1 5Kg e HPX 1200 4lbs 1 8Kg Compatible HPX Modules and Panels HPX 600 900 1200 Hydraport Base Assemblies are compatible with the following HPX Modules and Panels HPX AV101 HDMI FG552 24 Single HDMI Module with Integrated Cable HPX AV101 DVI Lo Single DVI Module with Integrated Cable HPX AV101 DVI A FG552 22 DVI
8. uirements for installing the HPX Base Assembly FIG 2 indicates the dimensions above the table 5 43 _ 138 0 See table below for the length of B for each HPX model FIG 2 Dimensions of the HPX Base Assembly above the table HPX 1200 Holds up to 12 HPX Modules 14 09 358 mm HPX 900 Holds up to 9 HPX Modules 11 14 283 mm HPX 600 Holds up to 6 HPX Modules 8 19 208 mm page 2 of 4 FIG 3 indicates the dimensions above the table 0 29 MAX 7 3 i 6 9 MAX 175 FIG 3 Dimensions of the HPX Base Assembly below the table e The Hydraport system requires a mounting surface from 0 5 13mm to 2 51mm thick e The Hydraport system requires at least 6 15 16 175 mm below the mounting surface Note Care should also be taken to ensure that the Hydraport system does not interfere with the normal use of the work space For example on a table or work surface ensure that the system does not interfere with the user s legs when they are seated at the table 2 Cut the Hole In the Mounting Surface FIG 4 provides the Hole cutout dimensions for the HPX Base Assembly 4 84 123 0 See table below for the length of A for each HPX model FOR TABLE THICKNESS 0 75 19 2 0 51 FIG 4 HPX Base Assembly Hole cutout dimensions HPX 1200 Holds up to 12 HPX Modules 13 54 344 mm HPX 900 Holds up to 9 HPX Modules 10 59 269 mm