Home
Pyle Power Inverter 800W
Contents
1. PNVR800 is also activated and AC power will be delivered to the AC outlet B RED It indicates the inverter shut down caused by low voltage overload or excessive temperature The ON OFF switch It enables output AC power at the AC outlet when switched ON It also acts as a manual reset for overload low battery voltage and overheat fault conditions Reset occurs by switching OFF for 5 seconds after automatic shout down then back ON again This manual reset feature prevents unexpected or hazardous restarting of connected AC loads The AC outlet Dual AC outlets are provided on one end of the PNVR300 PNVR450 and PNVR800 make sure of the power consumption required before plug in A When operated from a vehicle cigarette lighter PNVR300 PNVR450 a consumption of 220 Watts or less for PNVR300 and any combination of 115 Volt AC products with a total power consumption of 220 Watts or less for PNVR300 B When operated from the directly connection to a 12 Volt battery any combination of 115 Volt AC products with a total power consumption of 400 Watts CAUTION e Do not connect to AC DISTRIBUTION WIRING The inverter is designed for connection directly to standard electrical and electronic equipment e Do not connect the inverter to household or RV AC distribution wiring e Do not connect the inverter to any AC load circuit in which the neutral conductor is connected to ground earth or to the negative of DC battery source The
2. PYLE PNVR450 PNVR800 OWNER S MANUAL POWER INVERTER PNVR300 150WATT PNVR450 220WATT PNVR800 400WATT www pyleaudio com INTRODUCTION Thank you for purchasing the PYLE DC to AC Power Inverter The PNVR300 PNVR450 PNVR800 will deliver an efficient power to a wide variety of household AC products or electronic appliance reliably from the 12 volt outlet in your vehicle or boat or directly from a 12 Volt battery to serve such as most TVs VCRs Play Stations Work Lights Soldering Irons etc Please pay your special attention to all CAUTION and WARNING statements Improper use of this inverter can cause personnel injury property damage and or loss of life WARNING e Shock Hazard Keep away from children e The PNVR300 PNVR450 PNVR800 Generates the same potentially lethal AC power as normal household wall outlet Treat it with the same respect that you would do to any AC outlet e The PNVR300 PNVR450 PNVR800 is designed for indoor use only and not recommended for use with inductive loads such as florescent lamps compressors amp pumps e Ensure to maintain at least 2 inch 5cm air space on all sides of this inverter as its housing may become uncomfortably warm reaching 140 F 60 C under extended high power e Disconnect power to the inverter when it is not in use e Do not expose this inverter to water rain snow or spray e Do not insert foreign objects into this inverter s AC outlets e Do not leave this inverter or an
3. e load to 150 Watts PNVR300 220 Watts PNVR450 and 400 Watts PNVR800 maximum to maintain regulation SYMPTOM D THE LOW BATTERY IS MEASURED POSSIBLE CAUSES SUGGESTION The poor battery condition Recharge battery Inadequate power of excessive voltage drop Check condition of battery clips and terminals Clean or replace as necessary SPECIFICATIONS AC output voltage nominal 115 Volts AC DC input voltage range 10 15 Volts DC Maximum Continuous AC output power 150 Watts PNVR300 220 Watts PNVR450 400 Watts PNVR800 300 Watts PNVR300 440 Watts PNVR450 800 Watts PNVR800 AC output frequency 60Hz 2Hz AC output waveform modified sine wave No load current draw less than 0 85A PNVR300 less than 0 95A PNVR450 less than 0 85A PNVR800 12 8 18 AMP PNVR300 18 25 AMP PNVR450 30 35 AMP PNVR800 Optimum efficiency Ambient operating temperature range Low battery shut down point nominal 9 8 10 4 Volts High battery shut down point nominal 15 Volts Number of ac receptacles 2 PNVR300 PNVR450 PNVR800 Specifications are typical individual units might vary Specifications are subject to change and improvement without notice 8
4. fuse replacement If the inverter is overload and the spade type fuse is blown open the fuse replacement cover at the rear of inverter and replace the blown fuse with a new spade type fuse 15A for PNVR300 25A for PNVR450 and 40A for PNVR800 Determine the cause of the short circuiting before restarting the inverter BATTERY OPERATING TIME The operating time of battery will vary depending on the charge level of the battery its capacity and the power level drawn by the particular AC load The vehicle batteries are not intended for constant deep discharge they are designed to provide brief periods of very high current needed for engine starting It is strongly recommended to start the vehicle every hour or two to recharge battery before its capacity drops too low Operating the inverter from a vehicle battery until the low voltage alarm sounds will shorten the battery s life The inverter can operate whether or not the vehicle s engine is running but the normal voltage drop that occurs during starting may trigger the inverter s low voltage shutdown feature The use of a deep discharge battery is strongly advised for longer operating times Its capacity should be selected based on the desired operating time PROTECTION SYMPTOMS PROTECTION The input reverse polarity The fuse blown The low voltage battery below DC 10V The unit auto shutdown The alarm sounds The RED LED lights The high input voltage over DC 15 6V The unit auto
5. s and present an Energy Hazard To prevent irritation and burns wear protective wear and clothing and take special care to ensure no metal tools or personal objects contact the battery terminals The Power Source Connection The power source must provide between 10 3 to 15 6 Volts DC and must be able to supply the necessary current to operate the load The power source may be a battery or a well regulated 12V 30A DC power supply To obtain the power source must deliver in amperes you can divide the power consumption of the load in watt by 12 the input voltage For example the load is rated at 150 Watts the power source must be able to deliver 150 12 12 5 Amp The inverter is equipped with a heavy duty DC lighter plug that fits standard vehicle cigarette lighter and DC power outlets With this lighter plug the inverter can power loads up to 220 Watts While using the battery cable please follow these steps A Turn off the power switch and be sure no flammable fumes are present B Connect the BLACK cable to the NEGATIVE terminal and RED cable to the POSITIVE terminal of the battery The reverse polarity connection wil result in a blown fuse and may cause permanent damage to the inverter Do not use the system with positive electrical grounding C Be sure to fasten all connections between battery chips and terminals The LED indicators A GREEN It indicates the inverter is power on the cooling fan PNVR300 PNVR450
6. shutdown The overload The RED LED lights The overheat TROUBLE SHOOTING SYMPTOM A NO AC POWER OUTPUT THE RED LED LIGHTS POSSIBLE CAUSES SUGGESTION The connected AC products are rated at more than 150 Watts Use the product with a total power rating PNVR300 220 Watts PNVR450 or 400 Watts PNVR800 less than 150 Watts PNVR300 220 Watts the overload shutdown occurred PNVR450 and 400 Watts PNVR800 The connected AC products are rated at less than 150 Watts Use the product not exceeds the inverter s PNVR300 220 Watts PNVR450 or 400 Watts PNVR800 surge capacity 300 Watts PNVR300 450 the high starting surge causes the overload shutdown Watts PNVR450 and 800 Watts PNVR800 The battery is discharged alarm sounds Recharge battery The inverter overheated Turn off the inverter and allow to cool for 15 minutes Clear blocked fan PNVR300 PNVR450 PNVR800 or remove the objects covering the ventilation SYMPTOM B NO AC POWER OUTPUT NO LED LIGHTS ARE ON The fuse of inverter is blown Check to make sure the inverter is connected to a power source with correct voltage and polarity Replace fuse The inverter has been connected with reverse DC input The inverter needs repjairment polarity if the probable damage has occurred SYMPTOM C THE LOW OUTPUT OF INVERTER IS MEASURED POSSIBLE CAUSES SUGGESTION Battery voltage is too low below 10V DC Recharge battery The inverter is overload Reduc
7. y device operating unattended to avoid property damage potentially e Do not use or place this inverter near flammable materials or any places which accumulate flammable fumes e Do not connect this inverter to power utility AC distribution wiring under any circumstance e Check the input and output connectors of this inverter are tight regularly The loose connections can generate harmful heat and of damage the inverter or power source CAUTION e Do not connect any AC product to this inverter whose neutral conductor is connected to ground e Do not expose this inverter to temperature in excess of 100 F 40 C e This inverter must be connected only to batteries with a normal output voltage of 12 Volts This unit will not operate from a 6 Volt battery and will be damaged if it is connected to a 24 Volt battery FEATURES PNVR300 PNVR450 PNVR800 1 AC OUTLET 2 ON OFF SWITCH 3 POWER ON LED 4 PROTECTION LED 5 LIGHTER PLUG POWER PROTECTION INPUT 12V OPERATION CAUTION DO NOT USE THIS INVERTER WITH THE FOLLOWING e Small battery operated appliances such as RECHARGEABLE FLASHLIGHTS SOME RECHARGEABLE SHAVERS and NIGHT LIGHTS that are plugged directly into as RECEPTACLE TO RECHARGE e BATTERY CHARGERS used with certain power tool battery packs These chargers will have a WARNING LABEL stating that DANGEROUS VOLTAGE ARE PRESENT AT THE CHARGERS BATTERY TERMINALS WARNING Batteries contain corrosive material
Download Pdf Manuals
Related Search
Related Contents
ŠKODA Citigo Betriebsanleitung Omega Vehicle Security LDP63100 Computer Monitor User Manual Cables Direct 2RR-200-05 Erste Schritte mit dem TI Istruzioni per l`uso Manual de usuario Sunways Modem analógico VarioTrack MPPT solar charge regulator VarioTrack グルーの取扱説明書(例) - まつげエクステのアイコスメ[松風] HP rp rp5800 Retail System Copyright © All rights reserved.