Omega Vehicle Security LDP63100 Computer Monitor User Manual
Contents
1. 3 TYPICAL INSTALLATIONS FOR NEMA 4 IP65 ENCLOSURE Figure 2 NEMA 4 IP65 LARGE DISPLAY ENCLOSURE amp SHROUD FOR LDP63100 BASEMOUNT WITH WATERTIGHT CABLE CONNECTOR ENTERING THROUGH REAR PANEL Removing the rear panel of the enclosure allows access to the Display for service Either the rear panel or housing may be drilled to accept sealed conduit fittings liquid tight cable fittings or other types of wiring connectors The enclosure may be attached to horizontal surfaces located above or below it using the mounting channels provided SUSPENDED FROM CONDUIT WITH SEALED FITTINGS SHOWN WITH SHROUD BEAM MOUNT WITH SEALED CONDUIT ENTERING FROM RIGHT SIDE Picture includes the LDP63100 NEMA Enclosure and Shroud 9 ASSEMBLY AND INSTALLATION PROCEDURE 1 Install the two mounting channels on the enclosure housing using the four 8 32 screws provided and then insert the strut nuts provided Invert enclosure if base mounting 2 If the wiring is to be routed through the housing make sure that the mounting channels are oriented properly before drilling so the Display will be readable Wiring is generally brought into the right side of the housing or rear panel closest to the terminals of the input module Drill the proper size hole in the housing or rear panel for the wiring connector or sealed conduit fitting and attach the fitting s 3 Before installing the Display into the housing be sure that the mounting channels ar
2. Enclosure rating Face only UL50 IEC 61010 1 EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 IP65 Enclosure rating Face only IEC 529 ELECTROMAGNETIC COMPATIBILITY EMC specifications determined by the model 6 ENVIRONMENTAL CONDITIONS Operating Temperature Range Determined by the model Storage Temperature Range 40 to 60 C Operating and Storage Humidity 0 to 85 max RH non condensing Altitude Up to 2000 meters 7 MOUNTING REQUIREMENTS Max panel thickness is 0 375 9 5 mm Min panel thickness for NEMA 4 IP65 sealing is 0 060 1 52 mm 8 MODULE INSTALLATION 24 pin shrouded connector on LDP63100 engages connector on input module upon installation Shroud ensures proper alignment by providing a lead in for the module connector 9 CONNECTIONS Wiring connections are made to the LDP63100 terminal block and input module via high compression cage clamp terminal blocks Input Module Wiring Instructions are provided in the included bulletin LDP63100 Terminal Block Wiring Wire Strip Length 0 3 7 5 mm Wire Gage 30 12 AWG copper wire Maximum Torque 5 7 inch lbs 0 58 0 81 N m CAUTION DISCONNECT ALL POWER BEFORE INSTALLING OR REMOVING MODULE 10 CONSTRUCTION Aluminum front panel enclosure and rear cover with textured black polyurethane paint for scratch and corrosion resistance protection Sealed front panel meets NEMA 4X IP65 specifications for indoor us
3. in the drawing Figure 2 Reinstalling an Input Module and Option Cards Figure 1 Removing an Input Module 6 2 0 INSTALLING THE DISPLAY DISPLAY INSTALLATION The LDP63100 display is intended to be mounted into a panel or enclosure The display is provided with a gasket to provide a water tight seal The recommended minimum panel thickness for NEMA 4 IP65 sealing is 0 060 1 57 mm For panel mounting prepare the panel cut out to the dimensions shown in Figure 3 The supplied template may be used to mark the cut out and hole locations on the panel After the panel cut out has been deburred slide the panel gasket over the rear of the display and onto the mounting studs Insert the display into the panel cut out as illustrated in Figure 4 Install 14 10 32 keps nuts supplied and tighten evenly for uniform gasket compression Do not over tighten the nuts By using additional mounting accessories the LDP63100 can be surface wall mounted suspended or bottom mounted Separate installation instructions are provided with the mounting accessories Environment And Cleaning The display should be installed in a location that does not exceed the maximum operating temperature and provides good air circulation Placing the system near devices that generate excessive heat should be avoided The bezel should be cleaned only with a soft cloth and neutral soap product Do NOT use solvents Continuous exposure to direct sunlight may accelera
4. 493 0607
5. I Need for Process Measurement and Control OMEGA Of Course Shop online at omega com TEMPERATURE Thermocouple RTD amp Thermistor Probes Connectors Panels amp Assemblies Wire Thermocouple RTD amp Thermistor Calibrators amp Ice Point References Recorders Controllers amp Process Monitors Infrared Pyrometers PRESSURE STRAIN AND FORCE Transducers amp Strain Gages Load Cells amp Pressure Gages Displacement Transducers Instrumentation amp Accessories FLOW LEVEL Rotameters Gas Mass Flowmeters amp Flow Computers Air Velocity Indicators Turbine Paddlewheel Systems Totalizers amp Batch Controllers pH CONDUCTIVITY pH Electrodes Testers amp Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators amp Pumps Industrial pH amp Conductivity Equipment DATA ACQUISITION Data Acquisition amp Engineering Software Communications Based Acquisition Systems Plug in Cards for Apple IBM amp Compatibles Datalogging Systems Recorders Printers amp Plotters HEATERS Heating Cable Cartridge amp Strip Heaters Immersion amp Band Heaters Flexible Heaters Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL Metering amp Control Instrumentation Refractometers Pumps amp Tubing Air Soil amp Water Monitors Industrial Water amp Wastewater Treatment pH Conductivity amp Dissolved Oxygen Instruments M4
6. LDP63100 Extra LLarge DDisplay omega com e mail info omega com For latest product manuals omegamanual info User s Guide Shop online at LP0689X OMEGAnet Online Service omega com Internet e mail info omega com Servicing North America U S A One Omega Drive P O Box 4047 ISO 9001 Certified Stamford CT 06907 0047 TEL 203 359 1660 FAX 203 359 7700 e mail info omega com Canada 976 Bergar Laval Quebec H7L 5A1 Canada TEL 514 856 6928 FAX 514 856 6886 e mail info omega ca For immediate technical or application assistance U S A and Canada Sales Service 1 800 826 6342 1 800 TC OMEGA Customer Service 1 800 622 2378 1 800 622 BEST Engineering Service 1 800 872 9436 1 800 USA WHEN Mexico En Espa ol 001 203 359 7803 e mail espanol omega com FAX 001 203 359 7807 info omega com mx Servicing Europe Czech Republic Frystatska 184 733 01 Karvin Czech Republic TEL 420 0 59 6311899 FAX 420 0 59 6311114 Toll Free 0800 1 66342 e mail info omegashop cz Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de United Kingdom One Omega Drive River Bend Technology Centre ISO 9002 Certified Northbank Irlam Manchester M44 5BD United Kingdom TEL 44 0 161 777 6611 FAX 44 0 161 777 6622 Toll Free in United Kingdom 0800 488 488 e mail sa
7. OUD INSTALLATION PROCEDURE Installing The Shroud On An LDP63100 Display In A NEMA 4 IP65 Enclosure Or Panel 1 Place a gasket over the studs extending from the rear of the front panel of the Display 2 Orient the shroud as shown in Figure 6 and place it over the display The studs of the display should now be protruding through the rear of the shroud 3 Place the other gasket over the studs 4 Install the unit into the panel or enclosure using the 10 32 keps nuts that are supplied with the Display Tighten the nuts firmly Figure 5 Figure 6 Nema 4 IP65 Shroud Installation Supplied with LDP63100 Supplied with LDP63100 DIMENSIONS In inches mm PART NUMBER INFORMATION DESCRIPTION PART NUMBERS Temperature Input 85 250 VAC power LDP63100 T Universal DC Inputs 85 250 VAC power LDP63100 DC True RMS AC Current and Volt Inputs 85 250 VAC power LDP63100 AC Process Input 85 250 VAC power LDP63100 E Strain Gage Input 85 250 VAC power LDP63100 S ACCESSORIES LDP631 SHR Shroud LDP6 PGM Programming Remote LDP6 EN SH NEMA 4 Enclosure With Shroud LDP6 ENC12 NEMA 4 Enclosure PART NUMBERS DESCRIPTION WARRANTY DISCLAIMER OMEGA ENGINEERING INC warrants this unit to be free of defects in materials and workmanship for a period of 25 months from date of purchase OMEGA s WARRANTY adds an additional one 1 month grace period to the normal two 2 year product warranty to cover handling and ship
8. R NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PROCESSING DELAYS The assigned AR number should then be marked on the outside of the return package and on any correspondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit OMEGA s policy is to make running changes not model changes whenever an improvement is possible This affords our customers the latest in technology and engineering OMEGA is a registered trademark of OMEGA ENGINEERING INC Copyright 2006 OMEGA ENGINEERING INC All rights reserved This document may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without the prior written consent of OMEGA ENGINEERING INC FOR WARRANTY RETURNS please have the following information available BEFORE contacting OMEGA 1 Purchase Order number under which the product was PURCHASED 2 Model and serial number of the product under warranty and 3 Repair instructions and or specific problems relative to the product FOR NON WARRANTY REPAIRS consult OMEGA for current repair charges Have the following information available BEFORE contacting OMEGA 1 Purchase Order number to cover the COST of the repair 2 Model and serial number of the product and 3 Repair instructions and or specific problems relative to the product Where Do I Find Everything
9. RANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIABILITY The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RETURN A
10. ay FORM A Normally open only LDP6 CDS30 Isolated quad sinking NPN open collector LDP6 CDS40 Isolated quad sourcing PNP open collector ANALOG OUTPUT PLUG IN CARD LDP6 CDL Either a 0 4 20 mA or 0 10 V retransmitted linear DC output is available from the analog output plug in card The programmable output low and high scaling can be based on various display values Reverse slopes output is possible by reversing the scaling point positions LDP6 CDL10 Retransmitted Analog Output Card COMMUNICATION PLUG IN CARDS LDP6 CDC A variety of communication protocols are available for the LDP63100 series Only one of these cards can be installed at a time When programming the unit via Crimson the RS232 or RS485 Cards must be used PROGRAMMING SOFTWARE DP6 SOFT is a Windows based program that allows configuration of the LDP63100 meter from a PC This software offers standard drop down menu commands that make it easy to program the LDP63100 meter The program can then be saved in a PC file for future use A serial plug in card is required to program the meter using the software 5 CERTIFICATIONS AND COMPLIANCES SAFETY UL Recognized Component File E313607 UL61010A 1 CSA C22 2 No 1010 1 Recognized to U S and Canadian requirements under the Component Recognition Program of Underwriters Laboratories Inc UL Listed File E313547 UL508 CSA C22 2 No 14 M95 LISTED by Und Lab Inc to U S and Canadian safety standards Type 4X Indoor
11. ction Removing The Input Module To remove the input module from the LDP63100 Display first remove all power and load circuits Then insert a flat screwdriver blade 3 16 or 1 4 into the narrow slot between the LDP63100 rear cover plate and the module s plastic cover as illustrated in Figure 1 Twist the screwdriver in the direction shown to disengage the internal connectors while firmly squeezing and pulling back on the rear finger tabs top and bottom Carefully slide the module out of the case keeping it properly aligned with the case opening 1 0 ASSEMBLING THE DISPLAY Reinstalling the Input Module To reinstall the Input Module align the module with the opening in the LDP63100 case as illustrated The module must be oriented as shown with terminal 1 toward the top of the LDP63100 case Carefully slide the module into the LDP63100 case The LDP63100 and input module connectors will begin to engage about from the bottom At this point apply a small amount of pressure to the rear of the input module to fully engage the connection Be sure the module fully snaps into the slots at the rear of the LDP63100 case The input module holder can be removed with a nut driver to make inserting the module easier The display is ready for installation Installing the Labels Each option card and the input module are shipped with a connection label These labels must be applied to the rear of the LDP63100 in the positions shown
12. e oriented properly for the type of installation planned Place the gasket that is supplied with the Display over the studs extending from the front panel of the display 4 If using the shroud refer to the Shroud Installation Procedure Place the Display with gasket through the holes in the housing as shown at right Working back and forth across the stud pattern install the 10 32 keps nuts supplied with the Display on the studs Tighten firmly 5 Mount the housing using the strut nuts and steel 20 UNC bolts and washers as shown in figure 4 6 Connect the wires to the Display per the instructions included with the personality board 7 Remove the center section of the rear panel gasket Apply the gasket to the rear panel of the enclosure by inserting the 8 32 screws through the panel and into the holes in the gasket Position the panel on the housing start all of the screws then firmly tighten them in a pattern working back and forth across the rear panel DIMENSIONS FOR THE LDP63100 DISPLAY SHROUD The optional LDP63100 Display Shroud enhances the readability of the Displays that are installed in areas with high intensity overhead light sources The Shroud can be used with the LDP63100 Display in any installation panel mount NEMA 4 IP65 Enclosure or Universal Mounting Bracket When properly assembled the Shroud will not affect the integrity of a NEMA 4 IP65 installation The Shroud weighs 1 0 pound 0 45 Kg Figure 4 SHR
13. e when properly installed Installation Category II Pollution Degree 2 Panel gasket and keps nuts included 11 WEIGHT 5 lbs 2 25 kg less module OPTIONAL PLUG IN CARDS AND ACCESSORIES LDP6 CDC4C Modbus Connector LDP6 CDC40 Modbus Terminal LDP6 CDC1C RS485 Serial Connector LDP6 CDC2C RS232 Serial Connector LDP6 CDC10 RS485 Serial Terminal LDP6 CDC20 RS232 Serial Terminal 5 CAUTION The input module main circuit board and the option cards contain static sensitive components Before handling the module or the cards discharge static charges from your body by touching a grounded bare metal object Handle the module by the rear plastic cover only and the option cards by the board edges Dirt oil or other contaminants that contact the circuit boards or components can adversely affect circuit operation WARNING Exposed line voltage exists on the input module main circuit board and the option cards DO NOT apply power to the module OR load circuits until the module is properly installed in the LDP63100 case NOTE All module and option card labels must be installed as shown for safety purposes Installing the Option Cards Prior to installing the LDP63100 Display it is recommended that the option cards be assembled first This will allow you the opportunity to insure all the boards are fitted properly into their connectors Refer to the literature enclosed with the option cards for installation instru
14. in this and corresponding literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired The protective conductor terminal is bonded to conductive parts of the equipment for safety purposes and must be connected to an external protective earthing system SPECIFICATIONS Input specifications wiring and programming information is contained in the corresponding literature shipped with the ordered model 1 DISPLAY 4 101 mm Red LED 5 Digit 19999 to 99999 2 POWER REQUIREMENTS AC Input Modules 85 to 250 VAC 50 60 Hz 18 VA LDP63100 Display 85 to 250 VAC 50 60 Hz 10 VA 3 ANNUNCIATORS Display Indication Three vertical dots on the left side of the unit identify the displays for the following modes Setpoint Indication Four vertical dots on the right side of the unit identify the setpoint ON condition with SP 1 being the top position through SP 4 at the bottom 4 LDP63100 Programming The unit is a large display designed to be remotely mounted Therefore the unit does not have a programming keypad Unit programming should be accomplished by one of the following methods Rear Terminal Block External switches can be wired via the terminal block to allow unit programming A minimum of 3 switches would be required Optio
15. les omega co uk It is the policy of OMEGA Engineering Inc to comply with all worldwide safety and EMC EMI regulations that apply OMEGA is constantly pursuing certification of its products to the European New Approach Directives OMEGA will add the CE mark to every appropriate device upon certification The information contained in this document is believed to be correct but OMEGA accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are not designed for use in and should not be used for human applications 3 LARGE LED DISPLAY READABLE TO 180 FEET VARIOUS ANALOG INPUT MODULES DC VOLTAGE AND CURRENT PROCESS SIGNALS TRUE RMS VOLTAGE AND CURRENT THERMOCOUPLE OR RTD STRAIN GAGE BRIDGE ALARMS ANALOG OUTPUT AND COMMUNICATION PROGRAMMABLE USER INPUTS UNIVERSAL AC POWERED 85 to 250 VAC PROGRAMMING SOFTWARE NEMA 4X IP65 GENERAL DESCRIPTION The LDP63100 is a versatile display that can increase productivity by offering the plant floor or production area a large visual display of their current status Whether your measurement is voltage current process temperature or strain gage the LDP63100 can satisfy your requirement Plug in option cards can add alarms analog output and communication bus capabilities making the LDP63100 a truly Intelligent Panel Meter SAFETY SUMMARY All safety regulations local codes and instructions that appear
16. nal Programming Remote LDP6 PGM This option provides a 10 foot interconnecting cable and programming box The Programming Remote contains buttons allowing easy programming of the display Optional Serial Programming You can purchase an RS232 or RS485 Comms Card and program the unit via Crimson a Windows based software program DIMENSIONS In inches mm CAUTION Risk of Danger Read complete instructions prior to installation and operation of the unit CAUTION Risk of electric shock TOP Maximum MIDDLE Minimum BOTTOM Total C US LISTED UL R IND CONT EQ 51EB 4 WARNING Disconnect all power to the unit before installing Plug in cards Adding Option Cards The LDP63100 series meters can be fitted with up to three optional plug in cards The details for each plug in card can be reviewed in the specification section of the included manual Only one card from each function type can be installed at one time The function types include Setpoint Alarms LDP6 CDS Communications LDP6 CDC and Analog Output LDP6 CDL The plug in cards can be installed initially or at a later date SETPOINT ALARMS PLUG IN CARDS LDP6 CDS The LDP63100 series has 4 available setpoint alarm output plug in cards Only one of these cards can be installed at a time Logic state of the outputs can be reversed in the programming These plug in cards include LDP6 CDS10 Dual Relay FORM C Normally open amp closed LDP6 CDS20 Quad Rel
17. ping time This ensures that OMEGA s customers receive maximum coverage on each product If the unit malfunctions it must be returned to the factory for evaluation OMEGA s Customer Service Department will issue an Authorized Return AR number immediately upon phone or written request Upon examination by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion or current heat moisture or vibration improper specification misapplication misuse or other operating conditions outside of OMEGA s control Components in which wear is not warranted include but are not limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA either verbal or written OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects OMEGA MAKES NO OTHER WAR
18. s LDP63100 PROGRAMMING The unit is a large display designed to be remotely mounted Therefore the unit does not have a programming keypad Unit programming must be accomplished by one of the following three methods 8 LIGHT WEIGHT ALUMINUM CONSTRUCTION COMPLETELY SEALED FOR WASH DOWN MOUNTING CHANNELS FOR VERSATILE INSTALLATION DESCRIPTION The NEMA 4 IP65 Large Display Enclosure is designed to protect the LDP63100 from dust and hose directed water when properly installed This light weight all aluminum unit utilizes welded seams and neoprene gaskets to meet NEMA 4 IP65 requirements A textured polyurethane coating protects against corrosion and is scratch resistant Figure 1 below shows the overall dimensions of the Enclosure The Display Enclosure with Mounting Channels weighs 9 pounds 4 1 Kg DIMENSIONS In inches mm MOUNTING Provided with the enclosure are two 20 UNC x 1 hex bolts two 20 UNC strut nuts and two washers The strut nuts can be installed anywhere in the channel by inserting them spring side down into the channels then rotating them 90 degrees clockwise until the notches engage with the lips of the channel The bolts and washers provided allow mounting to surfaces to thick 6 4 to 12 7 mm Use longer bolts for mounting to thicker surfaces Bolts fabricated from materials other than steel are not recommended Housing Only Overall Including Screwheads Figure 1 Figure
19. te the aging process of the bezel Figure 4 Installing The LDP63100 Into A Panel Figure 3 Panel Cut out for the LDP63100 DIMENSIONS In inches mm 7 Once assembled the LDP63100 has all the same functions and capabilities of our DP63500 DP63600 and DP63700 Series Intelligent Panel Meters Therefore you will find the appropriate meter information packed with the LDP63100 Simply follow the instructions to wire and program the display for your application Note Both the LDP63100 and the input module require power It is recommended to connect the primary AC power to the LDP63100 terminal block then jumper to the input module 3 0 WIRING AND PROGRAMMING THE DISPLAY LDP63100 TERMINAL BLOCK RJ12 CONNECTOR ON BOTTOM OF UNIT Rear Terminal Block External normally open switches can be wired via the terminal block to allow unit programming A minimum of 3 switches would be required Each external switch must be wired between the key and the common terminal Optional Programming Remote LDP6 PGM This optional programming remote plugs into the LDP63100 through an RJ12 connector and a 10 foot cable The buttons on the programming box function the same as the DP63500 DP63600 and DP63700 meters Simply program the LDP63100 exactly as the meter instructions indicate The programming box can be left connected to the LDP63100 for future programming changes or can be disconnected and used to program additional LDP63100 unit
Download Pdf Manuals
Related Search
Related Contents
Husqvarna 335LX-SERIES 335LS User's Manual セレーノ25 スリット窓タイプ ダイヤル式・コード式 取扱説明書 Salora 19LED7000T User's Manual Linear AK-3 User's Manual General International 75-200RC M1 Use and Care Manual GB - ENGLISH Operating Instructions [ 富士ドライケムスライド Hb-WII ] ≫PDF Mod Podge CS15062 Instructions / Assembly Honours Project Copyright © All rights reserved.