Home
Eaton ENV800H uninterruptible power supply (UPS)
Contents
1. lt IMPORTANT SAFETY G INSTRUCTION SAVE THESE INSTRUCTION This manual contains important instructions for models ENV400L H ENV600L H ENV800L H that should be followed during installation and maintenance of the UPS and batteries Safety Caution This UPS utilizes voltage that may be hazardous Do not attempt to disassemble the unit The unit contains no user replaceable parts Only factory service personnel may perform repairs Internal battery voltage is 12Vdc Sealed lead acid 6 cells battery Connection to any other type of receptacle other than a two pole three wire grounded receptacle may result in shock azard as well as violate local electrical codes In the event of an emergency press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the PS Do not place beverages or any other liquid containing vessels on or near the unit This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in locations where there is standing or running water or excessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum c
2. On Off To turn on the UPS unit press the power switch lightly To turn off the UPS unit press the power switch again DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged Just simply press the power switch to turn on the UPS Green Power Function This Series are equipped with Green Power Function For saving power and protecting battery the method of deep discharging protection is adopted on inverter mode Free Software Download WinPower WinPower is a brand new UPS monitoring software which provides user friendly interface to monitor and control your UPS This unique software provides safely auto shutdown for multi computer systems while power failure With this software users can monitor and control any UPS on the same LAN no matter how far from the UPSs S WinPower Manager Ver 1 0 o x System Logs UPS Tools Monitor Preference Language Help KEE E UPS Status UPS Normal S cs 2000 com aa 3 war peni On Battery a fst 00 00 00 backup 1 s Model OFF LINE Com Port COMI BATTERY Temp 380 C 00y 200401720 14 44 33 Agent Start gt Installation procedure 1 Go to the website 2 Choose the operation system you need and follow the instruction described on the website to downl
3. Sounding every 2 seconds Fault Continuously Sounding PROTECTION Full Protection Discharge overcharge and overload protection PHYSICAL ENVIRONMENT Dimension mm DxWxH 330x100x140 Net Weight Operating Environment 5kgs 6kgs 6 5kgs 0 40 C 0 90 relative humidity non condensing Noise Level Less than 40dB INTERFACE USB Windows 98 2000 ME XP W Trouble Shootin o Symptom Possible Cause Remedy No LED 1 Missing battery 1 Charge battery up display on to 8 hours the front 2 Battery defect 2 Replace with the panel same type of battery 3 Power switch is not 3 Press the power pressed switch again Alarm buzzer Overload of the UPS Verify that the load beeps matches the UPS continuously capability specified when AC inthe specs supply is normal When power 1 Overload of the UPS 1 Remove some failure noncritical load backup time 2 Battery voltage is 2 Charge battery 8 is short too low hours or more 3 Battery defect due to 3 Replace with the high temperature same type of operation battery environment or improper operation to battery Mains normal 1 Fuse is blown 1 Replace the same but LEDis type of fuse flashing 2 Power cord is loose 2 Reconnect the power cord properly If any abnormal situations occur that are not listed above please call service people immediately
4. ETN Powering Business Worldwide USER MANUAL Eaton ENV400L H Eaton ENV600L H Eaton ENV800L H www eaton com nvups Front Panel 1 Power Switch 2 LED Indicators AC Mode Green Lighting Battery Mode Green Flashing COTA Back Panel 1 Output 2 AC fuse 3 Modem Phoneline Surge Protection 4 AC Input 5 USB Communication Port 6 Breaker RD z MODEL Specification ENV400L H ENV600L H ENV800L H CAPACITY VA 400VA 600VA 800VA INPUT Voltage 110 120VAC or 220 230 240VAC Voltage Range 81 145VAC or 162 290VAC Frequency 45 65Hz Auto sensing Voltage 110 120VAC or 220 230 240VAC Voltage Regulation Batt Mode 10 Frequency 50Hz or 60Hz Frequency Regulation Batt Mode 1Hz Output Waveform Modified Sinewave BATTERY Battery Type 12V4 5Ahx1 12V7Ahx1 12V9Ahx1 Backup Time at a PC load with 15 monitor 8 min 22 min 30 min Recharge Time 8 hours to 90 after complete discharge Typical 2 6 ms INDICATOR AC Mode Green lighting Backup Mode Backup Mode Green flashing Sounding every 10 seconds Low Battery Sounding every second Overload Sounding every 0 5 seconds Battery Replacement
5. leaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heater or furnaces Do not open or mutilate the battery or batteries Release PA is harmful to the skin and eyes It may be oxic Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole at the connectors of the battery when maintenance or service work inside the UPS is necessary Safety Caution Do not dispose of batteries in a fire as they may explode A battery can presenta risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries f 1 Remove watches rings or other metal objects from the hands 2 Use tools with insulated handles 3 Wear rubber gloves and boots 4 Do not lay tools or metal parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminal Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required pee eons Keep unauthorized personnel away from atteries When replacing batteries replace with the same number and type
6. oad the software 3 When downloading all required files from the internet enter the serial No 511C1 01220 0100 478DF2A to install the software When your computer restarts the WinPower software will appear as a green plug icon located in the system tray near the clock
7. of sealed lead acid battery This uggabie type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA Unplug the UPS prior to cleaning and do not use liquid or spray detergent 3 amp Wichtige Sicherheitshinweise Bitte lesen Sie diese Hinweis sorgfaltig durch Vor jedem rcinigen ist das Ger t vom Stromnetz zu trennen Verwenden Sie Keine Fl ssig oder Aerosolreiniger Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung Das Ger t ist vor Feuchtigkeit zu schutzen Offncn Sie niemals das Ger t Das Ger t darf aus Gr nden der elektrischen Sicherheit nur von authorisicrtem Servicepersonal geoffnct Werdcn Bei der Installation is darauf zu achten das der Gesamtableitstrom der USV und der and der USV angeschlossenen Verbraucher den Maximalwert von 3 5mA nicht ubershreiten VORSICHT Explosionsgetahr bei unsachgemaBen Austausch der Batterie Ersatz nur durch denselben order einem wom Hersteller empfoblenem hnlichen typ Entsorgung gebrauchter Batterien nach Angaben des Hertellers Introduction This UPS is specially designed for Personal Computer with multi functions Its ligh
8. ree from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high On the other hand place the UPS unit away from the monitor at least 20cm to avoid interference Charging This unit is shipped from the factory with its internal battery fully charged however some charge may be lost during shipping and the battery should be recharged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours 8 hours Computer Connection Connect one computer related device into each of the power receptacles supplied on the back of the UPS Modem Phoneline Connection O Plug incoming internet line into the In socket at the back of the UPS Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS Plug the other end to the modem input socket as shown below Incoming Internet line Serial cable Connection D To allow for unattended system shutdown for your operating system For the USB serial cable only available for the models with USB port just simply plug into the UPS and PC and it will be auto detected Turn
9. t weight compact design perfect fits to the limited working environment The line of UPS is equipped with boost and buck AVR to stabilize input voltage range Itis also built in with DC start function This function enables the UPS to be started up without AC power supplied The download software helps users monitor UPS inside status The main features of this UPS are listed below Microprocessor control guarantees high reliability Equipped with Boost and Buck AVR to stabilize the input voltage DC Start Function Free Software Download from the Internet Please check Free Software Download for detail information Green Power Function for energy saving Auto restart while AC recovery Compact size Light weight Provides Modem and Phoneline Surge Protection Provide AC Overload Protection USB lt gt g Installation and Operation Installing this UPS is as easy as following the steps shown Be aware of the Power Switch must be kept in the ON position otherwise the UPS will be disabled and your equipment will not be protected during a power failure Inspection J Remove the UPS from its package and inspect it for damage that may have occurred during shipping If any damage is discovered re pack the unit and return it to the place of purchase Placement 2 Install the UPS unit in any protected environment that provides adequate airflow around the unit and is f
Download Pdf Manuals
Related Search
Related Contents
STB software User guide for phase rotation meter TM603 Scarica l`allegato LED BUTTERFLY user manual.cdr - Professional Sound Light 2_5 eSATA USB Evolution User Guide Portails La Toulousaine NetOp School 5.5 - Teacher Copyright © All rights reserved.
Failed to retrieve file