Tripp Lite SMX2200RT2UTAA uninterruptible power supply (UPS)
Contents
1. CERTIFICATIONS UPS Certifications UPS Certification details WARRANTY Product Warranty Period U S Canada amp Puerto Rico Related Items Optional Products Product Type External Battery Packs 2 4 milliseconds 174V 220V 158V 230V 166V 240V 266V 220V 278V 230V 290 V 240V Cold start operation supported Hot swappable batteries Greater than 95 efficiency GREEN UPS Individually controllable load banks Tested to CE EU Tested to GOST Russia Tested to SASO Saudi Arabia Meets FCC Part 15 Category A EMI ROHS Restriction of Hazardous Substances TAA Compliant CE IEC 62040 TUV with GS mark 2 year limited warranty Related Model Description BP48V24 2U BP48V242U External Battery Pack for UPS System Qty External Battery Packs BP48V60RT 3U External Battery Pack and Cable 3U Expandable Blue 2 Point 1 Connector Power Distribution PDU12IEC Basic PDU Power Distribution Unit Safe reliable power distribution 1 for critical networking equipment Rackmount Wallmount Kits 2POSTRMKITWM Enables 2 Post Rackmount or Wallmount Installation of Select 1 Rackmount UPS Systems SNMP Accessories ENVIROSENSE Monitors temperature humidity and contact closure inputs Requires 1 SNMPWEBCARD or switched PDU SNMP Accessories SNMPWEBCARD For remote monitoring and control via SNMP Web or Telnet 1 Software WATCHDOGSW WatchDog Service Monitoring Reboot Software 1 Surge Protectors
2. DCATV Network Surge Suppressor Essential protection for TV VCR coaxial 1 lines Surge Protectors DNET1 Network Surge Suppressor Essential protection for data and 1 communication lines Surge Protectors DTEL2 Network Surge Suppressor Essential protection for data and 1 communication lines Tower Stands 2 9USTAND Enables Tower Placement of Rackmount UPS Systems 1 USB Hubs Accessories U022 010 10 ft USB2 0 A B Gold Device Cable 1 A Male to B Male More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModellD 4398 Copyright 2011 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products
3. and overvoltages from 158 290V 2200VA 1600W power handling capability and full time sine wave output offers guaranteed compatibility with networking telecom and other sensitive electronic applications 8 C13 outlets including 3 load banks 1 outlet each that are individually switchable via software interface to reboot select equipment on demand or shed less significant loads to extend battery runtime for more critical equipment Supports simultaneous remote monitoring of UPS and site power conditions via built in USB and DB9 monitoring ports HID compliant USB interface enables full integration with built in power management and auto shutdown features of Windows and Mac OS X Includes PowerAlert UPS monitoring and unattended shutdown software with complete cabling Built in accessory slot supports SNMP with optional SNMPWEBCARD adapter Emergency Power Off EPO interface offers option for instantaneous power off of UPS and connected equipment in case of fire or emergency Multi function audible alarms and 5 front panel LEDs offer at a glance notification of UPS and line power status Network grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges and line noise Attractive all black color scheme 2 year warranty Package Includes e SMX2200RT2UTAA TAA Compliant UPS System e PowerAlert Software CD and cabling e EPO cabling e 3 IEC320 C13 to C14 jumper cables e Owner s manual with warranty in
4. TTERY Full load runtime minutes Half load runtime minutes Expandable battery runtime External battery pack compatibility DC system voltage VDC Battery recharge rate included batteries Replacement battery cartridge internal UPS battery replacement Battery Access Battery replacement description VOLTAGE REGULATION Voltage regulation description Overvoltage correction Undervoltage correction Severe undervoltage correction Pure Sine wave 8 2A 220V 8 0A 230V 7 5A 240V 220V AC 230V AC 240V AC C20 inlet IEC320 C20 input connection accepts a variety of detachable cordsets to match country or site specific wall receptacles 15A 6 min 1600w 17 min 800w Extended runtime supported via optional external battery packs BP48V24 2U limit 1 BP48V60RT 3U multi pack compatible 48 Less than 4 5 hours from 10 to 90 RBC94 2U Front panel battery access door Hot swappable user replaceable batteries Automatic voltage regulation AVR maintains line power operation with an input voltage range of 158 to 290 Voltage reduction of 12 applies when input is between 232 266V 220V 244 278V 230V or 254 282V 240V Voltage boost of 12 applies when input voltage is between 174 198V 220V 183 206V 230V or 191 216 Voltage boost of 24 applies when input voltage is between 158 206V 230V or 166 190V 240V LEDS ALARMS amp SWITCHES LED Indicators Alarms A
5. Tripp Lite ewe Oe 1111 West 35th Street TRIPP LITE Chicago IL 60609 USA r Telephone 773 869 1234 E mail saleshelp tripplite com Model SMX2200RT2UTAA TAA Compliant SmartPro Expandable Rack Tower UPS Intelligent line interactive network power management system Highlights e Compliant with the Federal Trade Agreements Act TAA for GSA Schedule purchases e 2200VA 2 2kVA line interactive extended run 2U rack tower UPS e Maintains sine wave 230V nominal output during brownouts to 158 and overvoltages to 278V e Network communications supported via HID compliant USB port DB9 serial port SNMP Web card slot and EPO interface e Current monitoring and switched PDU control via 3 controllable load banks e Input C20 inlet Output 8 C13 Jumpers Includes 3 C13 to C14 cables e 2 year warranty Description Tripp Lite s SMX2200RT2UTAA is compliant with the Federal Trade Agreements Act TAA for GSA Schedule purchases This intelligent line interactive rack tower uninterruptible power supply prevents data loss downtime and equipment damage due to power outages voltage fluctuations and transient surges Requires only two rack spaces 2U in a standard rack enclosure Large internal batteries offer 17 min half load runtime and 6 min at full load Runtime is expandable with optional BP48V24 2U or BP48V60RT 3U external battery packs Maintains regulated 230V nominal output without using battery power during brownouts
6. aterial Cooling method ENVIRONMENTAL 350 Instantaneous Yes 4 post 19 inch rackmount mounting rail kit included 2 post rackmount 2POSTRMKITWM Wallmount 2POSTRMKITWM Tower 2 9USTAND Rackmount 3 5 x 17 5 x 19 8 9 x 44 4 x 48 3 2U Tower requires 2 9USTAND 17 5 x 3 5 x 19 44 4 x 8 9 x 48 3 61 27 7 9 x 23 5 x 20 22 9 x 59 7 x 50 8 72 32 7 Steel Fan Operating Temperature Range Storage Temperature Range Relative Humidity AC mode BTU hr full load Battery mode BTU hr full load COMMUNICATIONS Communications interface Network monitoring port description PowerAlert software Communications cable WatchDog compatibility 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 0 to 95 non condensing 54 9 538 USB HID enabled DB9 Serial EPO emergency power off Slot for SNMP Web interface Supports detailed monitoring of UPS and site power conditions Included USB and DB9 cabling included Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer time Low voltage transfer to battery power setpoint High voltage transfer to battery power setpoint SPECIAL FEATURES Cold Start startup in battery mode during a power failure High availability UPS features Green amp high efficiency features
7. formation Features e Compliant with the Federal Trade Agreements Act TAA for GSA Schedule purchases e 2200VA 1600W output power capacity compatible with 230V 50 60Hz power e 2U rack tower UPS installs in standard 19 in rack enclosures with an installed depth of only 19 in e Protects sensitive networking equipment from blackouts voltage fluctuations and transient surges e Large internal batteries offer 17 min runtime at half load 1100VA and 6 min at full load 2200VA e Runtime is expandable with external battery packs BP48V24 2U limit 1 or BP48V60RT 3U multi pack compatible e 8 C13 outlets including 3 load banks 1 outlet each that are individually switchable via software interface to reboot select equipment on demand or shed less significant loads to extend battery runtime for more critical equipment e IEC320 C20 input connection accepts a variety of detachable cordsets to match country or site specific wall receptacles e Line interactive automatic voltage regulation AVR corrects inputs from 158 278VAC back to usable 230V nominal levels without consuming battery power e Network interfaces support simultaneous communications via HID compliant USB port DB9 serial port and SNMPWEBCARD slot e Included PowerAlert UPS monitoring software supports safe unattended shutdown monitoring and control via local connected servers plus any number of additional servers over IP e HID compliant USB interface enables full integration with bu
8. ilt in power management and auto shutdown features of Windows and Mac OS X e Emergency Power Off EPO interface with cable e Built in accessory slot supports SNMP with optional SNMPWEBCARD adapter e Multi function audible alarms and set of 5 front panel LEDs e UPS battery set ships fully assembled no time consuming connection of internal batteries by user is required e 2 year warranty Specifications OUTPUT Output Volt Amp 2200 Capacity VA Output kVA capacity 2 2 kVA Output Watt Capacity 1600 watts Output kW capacity 1 6 Output power factor 0 7 Nominal Output Voltage s Supported Nominal Voltage details Frequency compatibility Output voltage regulation line mode Output voltage regulation Battery mode Built in UPS output receptacles Included output power cables Built in controllable switched load banks Basic PDU options Switched PDU options Output AC waveform AC mode 220V 230V 240V 230V default voltage selection via back panel dipswitches 50 60 Hz 15 8 5 8 C13 outlet s Includes 3 C13 to C14 output power cables Three switchable single outlet C13 load banks PDUNV 1U 2 C19 12 C13 outlets PDUMH15HVNET 1U 8 C13 outlets Sine wave Output AC waveform battery mode INPUT Rated input current at maximum load Nominal Input Voltage s Supported UPS input connection type UPS input connection description Input circuit breaker BA
9. larm cancel operation Switches 5 LEDs indicate line power battery power overload voltage regulation and battery low replace status Audible alarm indicates power failure overload and low battery conditions Power fail alarm can be silenced using alarm cancel switch once silenced alarm will re sound to indicate low battery status 2 Switches control off on power status and alarm cancel self test operation rear panel protected switches support low high charger settings SURGE NOISE SUPPRESSION UPS AC suppression joule rating UPS AC suppression response time EMI RFI AC noise suppression PHYSICAL Installation form factors supported with included accessories Installation form factors supported with optional accessories Primary form factor UPS Power Module dimensions in primary form factor height x width x depth inches UPS Power Module dimensions in primary form factor height x width x depth cm Installed whole system total rack space height rack spaces Secondary form factor Installed whole system dimensions in secondary form factor height x width x depth inches UPS dimensions in secondary form factor height x width x depth cm UPS Power Module weight Ibs UPS Power Module weight kg UPS Shipping dimensions height x width x depth inches UPS Shipping dimensions height x width x depth cm Shipping weight Ibs Shipping weight kg UPS housing m