        CyberPower CP900EPFCLCD uninterruptible power supply (UPS)
         Contents
1.  UPS is operating from its internal batteries  N  gt  PX AN 9  During a prolonged brownout or blackout  the Baw A pi e LOAD FAULT     gt     alarm will beep rapidly every 1 2 second  and the  2 SETTING TIME TO TURN O    EVENT TIME TO SHUT DOWN      3          BATT CAPACITY meter shows one 20  capacity AD        INPUT m    kVA    segment shaded  The capacity depends on how 10        OUTPUT DI   kW    i AR _ESTIMATED   Hz    much load added and the runtime left   to indicate Cama RUN TIME Li  LI ele    the UPS s batteries are nearly out of power  You ii ToTTTOTOTOTOTTOTOTOTOTOTOSOSSnnnn l Ca  should save files and turn off your equipment immediately or allow the software to shut the system  down    3  Energy Saving  The UPS in energy saving bypass mode  See    CyberPower GreenPower UPS   Technology    section for more information    4  LOAD capacity   Sensitivity setup  This meter displays the approximate output load level  in  20  increments  of the UPS battery outlets  It can also be sensitivity setup meter if you are in  programming mode  It is to control the sensitivity of the UPS to switch to Battery Mode by  selecting UPS shutdown voltage range  The higher the sensitivity  the easier the UPS will switch to  Battery Mode     10     11     12   13     14     BATTERY capacity  This meter displays the approximate charge level  in 20  increments  of the  UPS s internal battery  During a blackout or severe brownout  the UPS switches to battery power   the BATTERY icon appears  
2.  equipment with stable  220 230 output voltage  In the event of a  complete power loss  severe brownout  or over voltage  the UPS relies on its internal battery to  supply consistent 220 230 output voltage  The INPUT meter can be used as a diagnostic tool to  identify poor quality input power    EVENT  This meter records the number of power outages    MUTE  This icon appears whenever the UPS is in silent mode  The buzzer does not beep during  silent mode until the battery reaches low capacity    AVR  Automatic Voltage Regulation   This icon appears whenever your UPS is automatically  correcting low AC line voltage without using battery power  This is a normal  automatic operation  of your UPS  and no action is required on your part     For more information about functions setup  please refer to the Function Setup Guide     TECHNICAL SPECIFICATIONS       Model _______   CP900EPFCLCD  Capacity  VA  900VA 540W  Frequency Range 47 63Hz  Auto Sensing   AVR Function Yes  On Battery Output 230Vac    10   Voltage    On Battery Output 50 60Hz    1   Frequency    Transfer Time 4ms Typical  Overload Protection On Utility  Circuit Breaker  On Battery  Internal Current Limiting  Surge Protection    Lightning   Surge Yes  Protection    Network  Phone  Fax  RJ11 RJ45   One In  One Out    Modem Protection    Operating Temperature  32  F to 104  F   0  C to 40  C      Physical    Total   of UPS outlets Schuko x 6   Backup x 3      Maximum  Dimensions LxWxH  21 59  100  280M          Charging 
3. AC power source before  servicing the battery or installing a computer component    CAUTION  DO NOT USE WITH OR NEAR AQUARIUMS  To reduce the risk of fire  do not use with or  near aquariums  Condensation from the aquarium can come in contact with metal electrical contacts  and cause the machine to short out     INSTALLING YOUR UPS SYSTEM    UNPACKING   The box should contain the following     1  UPS Unit x 1   2  Telephone Cable x 1   3  USB Cable x 1   4  User Manual x 1   5  Management  software Disk x 1   6  Function Setup Guide x 1   OVERVIEW   The CP900EPFCLCD provides automatic voltage regulation for inconsistent utility power  The  CP900EPFCLCD features 405 Joules of surge protection  and provides battery backup during power  outages  The CP900EPFCLCD ensures consistent power to your computer system and its included  software will automatically save your open files and shut down your computer system during a utility  power loss    SUPPORTS Active PFC POWER SUPPLIES   This CyberPower UPS system supports High Efficiency power supplies with Active Power Factor  Correction  Active PFC   Active PFC is used to improve the efficiency of power delivery  The current US  Energy Star   Program Requirements for Computers  version 5 0  mandates Active PFC for all power  supplies over 100 watts  Additionally  programs such as 80 Plus   are often used to identify high  efficiency power supplies with Active PFC     HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR   EQUIPMENT   1 Make 
4. Current Max   0 6A  Yes  Status Indicators  Audible Alarms On Battery  Low Battery  Overload    Communication        PON ADS  secre Windows 7 Vista XP 2000 Server 2003  Linux  Edition Software    Management    Auto Charger  Auto Restart  USB interface       TROUBLESHOOTING    Circuit breaker button is Circuit breaker has    projecting from the back of   tripped due to an ti A MESS  the unit  overload  button  and then turn the UPS on     Battery not fully Recharge the battery by leaving the UPS  charged  plugged in     Contact CyberPower Systems about  replacement batteries at    Turn the UPS off and unplug at least one    The UPS does not perform  expected runtime  Battery is slightly worn    out  service cyberpower eu com    The on off switch is  designed to prevent Turn the UPS off  Wait 10 seconds and    damage by rapidly then turn the UPS on   turning it off and on     The UPS will not turn on  Contact CyberPower Systems about  replacement batteries at  service cyberpower eu com  Contact CyberPower Systems at  service cyberpower eu com  Connect the USB cable to the UPS unit  The USB cable is not and an open serial port on the back of the  connected  computer  You must use the cable that  came with the unit   The unit is not Shutdown your computer and turn the  providing UPS off  Wait 10 seconds and turn the  battery power  UPS back on  This should reset the unit     Additional troubleshooting information can be found at eu cyberpowersystems com    PowerPanel   Personal  
5. CyberPower       Reliability  Quality  Value        CP900EPFCLCD  User   s Manual    K01 0000190 00    IMPORTANT SAFETY INSTRUCTIONS    This manual contains important safety instructions  Please read and follow all instructions carefully  during installation and operation of the unit  Read this manual thoroughly before attempting to unpack   install  or operate your UPS    CAUTION  The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker  protection  DO NOT plug the UPS into an outlet that is not grounded  If you need to de energize this  equipment  turn off and unplug the UPS    CAUTION  DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT  CyberPower Systems  does not sell products for life support or medical applications  DO NOT use in any circumstance that  would affect the operation and safety of life support equipment  medical applications  or patient care   CAUTION  Hazardous live parts inside can be energized by the battery even when the AC input power  is disconnected    CAUTION  To prevent the risk of fire or electric shock  install in a temperature and humidity controlled  indoor area  free of conductive contaminants   Please see specifications for acceptable temperature  and humidity range     CAUTION  To reduce the risk of electric shock  do not remove the cover  except to service the battery   There are no user serviceable parts inside  except for the battery    CAUTION  To avoid electrical shock  turn off the unit and unplug it from the 
6. Edition is inactive        For more information  visit eu cyberpowersystems com or contact  Cyber Power Systems B V   E MAIL  sales cyberpower eu com    Entire contents copyright   2011 CyberPower Systems B V   All rights reserved  Reproduction    in whole or in part without permission is prohibited  PowerPanel   and PowerPanel   Plus are  trademarks of CyberPower Systems  USA  Inc     CE A      10    
7. TACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL  SHOCK  The likelihood of such shock will be reduced if such grounds are removed during  installation and maintenance  applicable to a UPS and a remote battery supply not having a  grounded circuit     BATTERY REPLACEMENT PROCEDURE     1  Turn off and unplug all connected equipment    2  Turn the UPS off and unplug it from the AC power source    3  Turn the UPS on its side    4  Remove the retaining screw located on the bottom of the UPS     5  Slide the battery compartment cover completely off of the unit    6  Remove the batteries from the compartment    7  Disconnect the battery wires from the batteries    8  Install the replacement batteries by connecting the red wire     and black wire     to the same color  connectors from the battery pack    9  Put the batteries back into the compartment    10  Slide back the battery compartment cover and tighten the retaining screw    11  Recharge the UPS for 8 16 hours to fully charge the battery     REMINDER  Batteries are considered HAZARDOUS WASTE and must be disposed of properly   Almost any retailer that sells lead acid batteries collects used batteries for recycling        1  ONLINE  The UPS is supplying utility power to poe EIA Reena eres  PERI       connected equipment          T U  2    i   ONLINE      BATTERY  During a severe brownout or    blackout  this icon appears and an alarm sounds  yo all   TTT        two short beeps followed by a pause  to indicate BATT  las  the
8. and the charge level decreases    FAULT  This icon appears if there is a problem with the UPS  Press the POWER button to turn off  the UPS    F01  Battery Mode or AC Utility Power Mode Overload fault  Turn on the UPS again     F02  Battery Output Short fault  Turn on the UPS again     F03  Charger Fault  Contact CyberPower Systems for support     F04  Internal Fault  Contact CyberPower Systems for support     OVER LOAD  This icon appears and an alarm sounds to indicate the battery supplied outlets are  overloaded  To clear the overload  unplug some of your equipment from the battery supplied  outlets until the icon turns off and the alarm stops    SCHEDULE  Users can setup the schedule to turn on and shut down the computer and UPS  through PowerPanel   Personal Edition software  The LCD display will show how much time that  the UPS is about to turn on or shut down    ESTIMATED RUNTIME  This displays the run time estimate of the UPS with current battery  capacity and load    OUTPUT meter  This meter measure  in real time  the AC voltage that the UPS system is  providing to the computer  such as normal AC line mode  AVR mode  and battery backup mode    Note  The OUTPUT meter shows the status of the battery backup outlets in terms of load   frequency  and voltage     INPUT meter  This meter measures the AC voltage that the UPS system is receiving from the  utility wall outlet  The UPS is designed  through the use of automatic voltage regulation  to  continuously supply connected
9. e the buzzer    6  Control Switch  Press the Control switch for 3 seconds in AC Utility Power Mode to perform a Self Test of the  battery    7  Battery and Surge Protected Outlets  The unit has three battery powered surge suppression outlets for connected equipment to ensure  temporary uninterrupted operation of your equipment during a power failure   DO NOT plug a laser  printer  paper shredder  copier  space heater  vacuum  sump pump or other large electrical  devices into the    Battery and Surge Protected Outlets     The power demands of these  devices may overload and damage the unit     8  Full Time Surge Protection Outlets  The unit has three always on surge suppression outlets    9  Circuit Breaker             Located on the back of the UPS  the circuit breaker serves to provide overload and fault protection   10  USB Port to PC  This port allows connection and communication from the USB port on the computer to the UPS unit   The UPS communicates its status to the PowerPanel   Personal Edition software   11  Communication Protection Ports RJ11 RJ45  Communication protection ports will protect any standard modem  fax  telephone line  or network  cable from surge and spikes   12  AC Input  Connect the AC Power cord to a properly wired and grounded outlet     HARDWARE INSTALLATION GUIDE    1  Your new UPS may be used immediately upon receipt  However  recharging the battery for at least 8  hours is recommended to ensure that the battery s maximum charge capacity is achie
10. ng extension cords    6  Depress the power switch to turn the unit on  The power on indicator light will illuminate and the unit  will  beep     7  If an overload is detected  an audible alarm will sound and the unit will emit one long beep  To  correct this  turn the UPS off and unplug at least one piece of equipment from the battery power  supplied outlets  Wait 10 seconds  Make sure the circuit breaker is depressed and then turn the UPS  on    8  Your UPS is equipped with an auto charge feature  When the UPS is plugged into an AC outlet  the  battery will automatically recharge    9  To maintain optimal battery charge  leave the UPS plugged into an AC outlet at all times    10  To store your UPS for an extended period  cover it and store with the battery fully charged   Recharge the battery every three months to ensure battery life     CYBERPOWER GREENPOWER UPS    TECHNOLOGY          CyberPower   s Green Commitment  CyberPower is dedicated to the development of green products  and has adopted  Green practices throughout its business  including  membership in Climate Savers  Computing Initiative  CSCI   accordance with the Restriction on Hazardous  Substances  ROHS   Waste Electrical and Electronic Equipment  WEEE  protocols   as well as ISO 14001 and IECQ QC080000  CyberPower pledges to provide the     i i   ENERGY SAVING    advanced energy solution for the environment and become a leading eco friendly TECHNOLOGY  organization in the UPS industry        Reduce Energy Cost 
11. sure that the total Volt Amp  VA  requirements of your computer  monitor  and  peripheral equipment does not exceed 900VA     2 Ensure that the equipment plugged into the battery power supplied surge outlets does  not exceed the UPS unit s rated capacity  900VA 540W for CP900EPFCLCD   If the rated unit  capacities are exceeded  an overload condition may occur and cause the UPS unit to shut down or  the circuit breaker to trip     BASIC OPERATION    DESCRIPTION    1  Power Switch  Used as the master on off switch  for equipment connected to the  battery power supplied outlets    2  Power On Indicator  This LED is illuminated when the  utility power is normal and the UPS  outlets are providing power  free of  surges and spikes    3  LCD Module Display  High resolution and intelligent LCD  display shows all the UPS  information with icons and  messages  For more information  please check the    Definitions for  Illuminated LCD Indicators     section    4  Display Switch  The switch can be used to select the LCD display contents including Input Voltage  Output Voltage  and Estimated Run Time  The toggle frequency is set to one time per 0 5 second  Press the switch  to roll down the function menu  Pressing the switch for 2 seconds will turn the LCD display on or off  while in AC Utility power mode    5  Silence Alarm Switch  The toggle frequency is set to one time per 0 5 second  Press the switch to roll up the function  menu  Holding the switch for more than 2 seconds will silenc
12. ved  Charge  loss may occur during shipping and storage  To recharge the battery  simply leave the unit plugged  into an AC outlet  The unit will charge in both the on and off position    Note  This UPS is designed with a safety feature to keep the system from being turned on during  shipment  The first time you turn the UPS on  you will need to have it connected to AC power or it will  not power up    2  If you will use the software  connect the USB cable to the USB port on the UPS    3  With the UPS unit off and unplugged  connect the computer  monitor  and any externally powered  data storage device  Zip drive  Jazz drive  Tape drive  etc  into the battery power supplied outlets   DO NOT plug a laser printer  copier  space heater  vacuum  paper shredder or other large electrical  device into the battery power supplied outlets  The power demands of these devices will overload  and possibly damage the unit    4  To protect a fax  telephone  modem line or network cable  connect a telephone cable or network  cable from the wall jack outlet to the IN jack of the UPS  Then connect a telephone cable or network  cable from the OUT jack on the UPS to the modem  computer  telephone  fax machine  or network  device    5  Plug the UPS into a 2 pole  3 wire grounded receptacle  wall outlet   Make sure the wall branch outlet  is protected by a fuse or circuit breaker and does not service equipment with large electrical  demands  e g  air conditioner  refrigerator  copier  etc  Avoid usi
13. with GreenPower UPS    Technology   CyberPower s goal is not only to provide eco friendly products but also to bring the best value for  consumers  The advanced energy saving design improves the operating efficiency and eliminates  waste energy consumption  As a result  consumers will enjoy significant energy cost savings with the  adoption of GreenPower UPS    technology     BATTERY REPLACEMENT          CAUTION  Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the  battery  Service the battery under the supervision of personnel knowledgeable of  batteries and their precautions    CAUTION  Use only the specified type of battery  See your dealer for replacement batteries   CAUTION  The battery may present the risk of electrical shock  Do not dispose of batteries in  a fire  as they may explode  Follow all local ordinances regarding proper disposal of batteries   CAUTION  Do not open or mutilate the batteries  Released electrolyte is harmful to the skin  and eyes and may be toxic    CAUTION  A battery can present a high risk of short circuit current and electrical shock  Take  the following precautions before replacing the battery    1  Remove all watches  rings or other metal objects    2  Only use tools with insulated handles    3  DO NOT lay tools or other metal parts on top of battery or any battery terminals    4  Wear rubber gloves and boots    5  Determine if the battery is inadvertently grounded  If inadvertently grounded  remove source  of ground  CON
    