1. Please read the following safety information carefully before installing the Switch WARNING Installation and removal of the unit must be carried out by qualified personnel only e This guide is intended for use by network administrators who are responsible for setting up and installing network equipment consequently it assumes a basic working knowledge of LANs Local Area Networks e The unit must be connected to an earthed grounded outlet to comply with international safety standards e Do not connect the unit to an A C outlet power supply without an earth ground connection e The appliance coupler the connector to the unit and not the wall plug must have a configuration for mating with an EN 60320 IEC 320 appliance inlet e The socket outlet must be near to the unit and easily accessible You can only remove power from the unit by disconnecting the power cord from the outlet e This unit operates under SELV Safety Extra Low Voltage conditions according to IEC 60950 The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions vii France and Peru only This unit cannot be powered from IT supplies If your supplies are of IT type this unit must be powered by 230 V 2P T via an isolation transformer ratio 1 1 with the secondary connection point labelled Neutral connected directly to earth ground tImp dance la terre Power Cord Set Canada ce
2. 15 A 125 V ou NEMA 6 15P 15 A 250 V Danemark La prise m le d alimentation doit respecterla la section 107 2 D1 de norme DK2 1a ou DK2 5a Cordon lectrique Il doit tre agr dans le pays d utilisation Suisse La prise m le d alimentation doit respecter la norme SEV ASE 1011 La prise secteur doit tre conforme aux normes CEE 7 7 SCHU KO LE cordon Europe secteur doit porter la mention lt HAR gt ou lt BASEC gt et doit tre de type HO3VVF3GO 75 minimum Bitte unbedingt vor dem Einbauen des RPU die folgenden Sicherheitsanweisungen durchlesen WARNUNG Die Installation und der Ausbau des Ger ts darf nur durch Fachpersonal erfolgen e Diese Anleitung ist fr die Benutzung durch Netzwerkadministratoren vorgesehen die fr die Installation und das einstellen von Netzwerkkomponenten verantwortlich sind sie setzt Erfahrung bei der Arbeit mit LANs Local Area Networks voraus Das Ger t sollte nicht an eine ungeerdete Wechselstromsteckdose angeschlossen werden e Das Ger t mu an eine geerdete Steckdose angeschlossen werden welche die internationalen Sicherheitsnormen erf llt e Der Ger testecker der Anschlu an das Ger t nicht der Wandsteckdosenstecker mu einen gem EN 60320 IEC 320 konfigurierten Ger teeingang haben e Die Netzsteckdose mu in der N he des Ger ts und leicht zug nglich sein Die Stromversorgung des Ger ts kann nur durch Herausziehen des Ger tenetzkabels aus
3. LiefAct Rear Panel The AC power connector is located on the rear panel of the switch INSTALLING THE SWITCH Before installing the switch verify that you have all the items listed under Package Contents Note that the switch can be installed on any suitably large flat surface or in a standard EIA 19 inch rack Package Contents The EZ Switch 10 100 includes e EZ Switch 10 100 SMC EZ1016DT or SMC EZ1024DT e Four rubber foot pads e Rack mount bracket kit e Appropriate AC power cord e This User Manual Selecting a Site Be sure to follow the site selection guidelines below when choosing a location e Select a suitable location for the switch o It should be accessible for installing cabling and maintaining the switch o The temperature and humidity should be within the ranges listed in the specifications The status LEDs should be clearly visible There should be adequate space approximately two inches on all sides for proper air flow e Make sure twisted pair cable is always routed away from power lines fluorescent lighting fixtures and other sources of electrical interference such as radios transmitters etc e Make sure that a properly grounded power outlet is within 2 44 meters 8 feet of the switch and is powered from an independent circuit breaker As with any equipment using a filter or Surge suppressor is recommended Instructions 1 Positioning the Switch For desktop or shelf mounting a
4. 2 2000 A2 2005 Limitation of voltage fluctuation and flicker in low voltage supply system according to EN 61000 3 3 1995 A1 2001 A2 2005 Immunity LVD Product family standard according to EN 55024 1998 A1 2001 A2 2003 Electrostatic Discharge according to EN 61000 4 2 2001 ED 1 2 Contact Discharge 4 kV Air Discharge 8 kV Radio frequency electromagnetic field according to EN 61000 4 3 2006 ED 3 0 80 1000 MHz with 1 kHz AM 80 Modulation 3 V m Electrical fast transient burst according to EN 61000 4 4 2004 ED 2 0 AC DC power supply 1 kV Data Signal lines 0 5 kV Surge immunity test according to EN 61000 4 5 2005 ED 2 0 AC DC Line to Line 1 kV AC DC Line to Earth 2 kV Immunity to conducted disturbances Induced by radio frequency fields EN 61000 4 6 2006 ED 2 2 0 15 80 MHz with 1 kHz AM 80 Modulation 3 V m Power frequency magnetic field immunity test according to EN 61000 4 8 2001 ED 1 1 1 A m at frequency 50 Hz Voltage dips short interruptions and voltage variations immunity test according to EN 61000 4 11 2004 ED 2 0 gt 95 Reduction 10 ms 30 Reduction 500 ms gt 95 Reduction 5000 ms EN 60950 1 2006 vi VCCI Class A TOEI FALE EFF BRS EHI RES VCCI ORCO SAM BAPE EE CT COUR AER TEN TALERD EB HO TILERBHVIET COGS IIE AAR TFT SLI BRANSZCLED DIET e
5. Caution Do not plug a phone jack connector into any RJ 45 port This switch instead use only twisted pair cables with RJ 45 connectors that conform with FCC standards TROUBLESHOOTING Diagnosing Switch Indicators 1 Symptom Power LED does not light after power on Probable Causes o AC power cord may be defective Possible Solutions o Check for loose connections o Check the power outlet by using it for another device o Replace the AC power cord 2 Symptom Link LED does not light after connection is made Probable Causes o Switch port network card or cable may be defective Possible Solutions o Check that the switch and attached device are both powered on o Be sure the network cable is connected to both devices o Verify that Category 5 or better cable is used for 10 100 Mbps connections and that the length of any cable does not exceed 100 meters 328 feet o Check the network card and cable connections for defects o Replace the defective card or cable if necessary CABLES Cable Specifications Cable Te and Specifications Cables Type Max Length Connector 2 pair Cat 3 or better 10BASE T 100 ohm UTP 100 m 328 ft RJ 45 2 pair Cat 5 or better 100BASE TX 100 ohm UTP 100 m 328 ft RJ 45 10BASE T 100BASE TX Pin Assignments Caution DO NOT plug a phone jack connector into any RJ 45 port Use only twisted pair cables with RJ 45 gt connectors that conform with FCC e ST 1 1 stan
6. LG ERICSSON 2 USER GUIDE SMC EZ1016DT EZ Switch 10 100 16 24 port SMC EZ1024DT Unmanaged Fast Ethernet Switch Copyright Information furnished by LG Ericsson USA Inc is believed to be accurate and reliable However no responsibility is assumed by LG Ericsson USA Inc for its use nor for any infringements of patents or other rights of third parties which may result from its use No license is granted by implication or otherwise under any patent or patent rights of LG Er icsson USA Inc LG Ericsson USA Inc reserves the right to change specifications at any time without notice Copyright 2011 LG Ericsson USA Inc All rights reserved LG Ericsson is a registered trademark Other products and company names are trademarks and registered trade marks of their respective holders Technical Support To Contact LG Ericsson Technical Support Phone 877 828 2673 Email support lgericssonus com Online http www lgericssonus com Warranty and Product Registration To register LG Ericsson products and to review the detailed warranty statement please refer to the LG Ericsson Website at http www lgericssonus com COMPLIANCES FCC Class A Federal Communication Commission Interference Statement This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equi
7. 16DT 16 RJ 45 10 100 BASE T ports SMC EZ1024DT 24 RJ 45 10 100 BASE T ports Indicator Panel Power Ports Link Act Dimensions SMC EZ1016DT 21 6x13 3x4 2cm 8 5x5 2x1 7in SMC EZ1024DT 26 7x16 1x4 2cm 10 5x 6 3x1 7in Weight SMC EZ1016DT 870g 1 9 lbs SMC EZ1024DT 1376g 3 Ibs MAC Address Table 8 K entries Memory Buffer SMC EZ1016DT 160Kbytes SMC EZ1024DT 160Kbytes Power Consumption SMC EZ1016DT 6 831 Watts SMC EZ1024DT 8 514 Watts Power Requirement Input Voltage 100 240 VAC 50 60 Hz Temperature Operating 0 40 C 32 104 F Humidity 10 to 90 non condensing EMC Safety Compliances CE Mark Immunity EN 61000 4 2 3 4 5 6 8 11 Emissions FCC Class A VCCI Class A LG ERICSSON SMC EZ1016DT SMC EZ1024DT Warranty Information and Product Registration To register LG Ericsson products and to review the detailed warranty statement please refer to the LG Ericsson Website at http www lgericssonus com Technical Support To Contact LG Ericsson Technical Support Phone 877 828 2673 Email support lgericssonus com Online http www lgericssonus com Copyright nformation furnished by LG Ericsson USA Inc is believed to be accurate and reliable However no responsibility is assumed by LG Ericsson USA Inc for its use nor for any infringements of patents or other rights of third parties which may result fr
8. ches are turned off the switches can save up to 59 for the power used And even under full traffic load the switches can still save up to 21 power consumption If cable length is less than 20 meters each switch can save up to 12 for the power used e Auto negotiation of half or full duplex and auto sensing of transmission speed on all ports e Auto configuration for MDI MDI X cable connection allows connections to servers workstations hubs or switches to be made with straight through cabling e ANSI IEEE 802 3u compliance ensures compatibility with standards based hubs switches and cards from any vendor e Store and forward switching ensures error free transmission e Half and full duplex flow control prevents packets from being dropped under heavy loading e Plug and play e At a glance LEDs for port and system status monitoring e Desktop and rack mountable Front Panel LEDs The front panel of the switch provides a link status LED for each RJ 45 port In addition the front panel also contains status LEDs for at a glance system monitoring The following table details the functions of the various indicators Port and Switch Status LEDs The switch is receiving power Ports Link Act The port has established a valid network connection Traffic is passing through the Off The port has not established any network connection Front Panel SMC EZ1024DT SMC EZ 101407 EZ Switch 10 100Mbps r
9. dards Use unshielded twisted pair UTP or shielded twisted pair STP cable for RJ 45 connections 100 ohm Category 3 or better cable for 10 Mbps connections or 100 ohm Category 5 or better cable for 100 Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Because all ports on this switch support automatic MDI MDI X operation you can use straight through cables for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI X and MDI port pinouts Pin MDI X Signal Name MDI Signal Name Receive Data plus RD Transmit Data plus TD Receive Data minus RD Transmit Data minus TD 3 Transmit Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD 4 5 7 8 Not used at 10 100 Mbps Not used at 10 100 Mbps PRODUCT SPECIFICATIONS EZ Switch 10 100 Standards Conformance IEEE 802 3 2002 Ethernet Fast Ethernet Full duplex flow control Communication Rate 10 and 100Mbps Communication Mode Full or half duplex at 10 100 Mbps Media Supported 10BASE T 100 ohm Category 3 or better twisted pair 100BASE TX 100 ohm Category 5 or better twisted pair Number of Ports SMC EZ10
10. der Netzsteckdose unterbrochen werden Der Betrieb dieses Ger ts erfolgt unter den SELV Bedingungen Sicherheitskleinstspannung gem IEC 60950 Diese Bedingungen sind nur gegeben wenn auch die an das Ger t angeschlossenen Ger te unter SELV Bedingungen betrieben werden Stromkabel Dies muss von dem Land in dem es benutzt wird gepr ft werden Schweiz Dieser Stromstecker mu die SEV ASE 1011Bestimmungen ein halten Das Netzkabel mu vom Typ HO3VVF3GO 75 Eine Mindestan forderung sein und die Aufschrift p lt HAR gt oder BASEC gt tragen Der Netzstecker mu die Norm CEE 7 7 erf llen SCHUKO xi Warnings and Cautionary Messages Warning This product does not contain any serviceable user parts Warning Installation and removal of the unit must be carried out by qualified personnel only Warning When connecting this device to a power outlet connect the field ground lead on the tri pole power plug to a valid earth ground line to prevent electrical hazards Caution Wear an anti static wrist strap or take other suitable measures to prevent electrostatic discharge when handling this equipment Caution Do not plug a phone jack connector in the RJ 45 port This may damage this device Les raccordeurs ne sont pas utilise pour le systeme t l phonique Caution Use only twisted pair cables with RJ 45 connectors that conform to FCC standards Warnings in German Achtung Dieses Produkt enth lt keine Teil
11. e die eine Wartung vom Benutzer ben tigen Achtung Installation und Deinstallation des Ger tes m ssen von qualifiziertem Servicepersonal durchgef hrt werden Achtung Wenn das Ger t an eine Steckdose angeschlossen wird mu der Masseanschlu n Netzstecker mit Schutzerde verbunden werden um elektrische Gefahren zu vermeiden Warnings in Korean Q o 77 202 AAT SSS 7 7 oey yaq HE SARS o BS 79 32417 A Ur AI MA Be THs Me Fage mga wy yc xii Environmental Statement The manufacturer of this product endeavors to sustain an environmentally friendly policy throughout the entire production process This is achieved though the following means e Adherence to national legislation and regulations on environmental production standards e Conservation of operational resources e Waste reduction and safe disposal of all harmful un recyclable by products e Recycling of all reusable waste content Design of products to maximize recyclables at the end of the product s life span e Continual monitoring of safety standards End of Product Life Span This product is manufactured in such a way as to allow for the recovery and disposal of all included electrical components once the product has reached the end of its life Manufacturing Materials There are no hazardous nor ozone depleting materials in this product Documentation All printed documentation for this product uses biodegradable paper that originate
12. n branchement sur une entr e d appareil EN 60320 IEC 320 e La prise secteur doit se trouver proximit de l appareil et son acc s doit tre facile Vous ne pouvez mettre l appareil hors circuit qu en d branchant son cordon lectrique au niveau de cette prise e L appareil fonctionne une tension extr mement basse de s curit qui est conforme la norme IEC 60950 Ces conditions ne sont maintenues que si l amp quipement auquel il est raccord fonctionne dans les m mes conditions France et P rou uniquement Ce groupe ne peut pas tre aliment par un dispositif imp dance la terre Si vos alimentations sont du type imp dance la terre ce groupe doit tre aliment par une tension de 230 V 2 P T par le biais d un transformateur d isolement rapport 1 1 avec un point secondaire de connexion portant l appellation Neutre et avec raccordement direct la terre masse Cordon lectrique Il doit tre agr dans le pays d utilisation Etats Unis et Le cordon doit avoir re u l homologation Can ada des UL et un certificat de CSA Les spe cifications minimales pour la corde flexible sont AWG No 18 ou AWG No 16 pour une longueur infe rieure a 2 me tres type SV ou SJ 3 conducteurs Le cordon doit tre en mesure d acheminer un courant nominal d au moins 10 A La prise femelle de branchement doit tre du type a mise a la terre mise a la masse et respecter la configuration NEMA 5 15P
13. om its use No license is granted by implication or otherwise under any patent or patent rights of LG Ericsson USA Inc LG Ericsson USA Inc reserves the right to change specifications at any time without notice Copyright 2011 LG Ericsson USA Inc All rights reserved LG Ericsson is a registered trademark Other products and company names are trademarks and registered trademarks of their respective holders EZ Switch 10 100 16 24 port Unmanaged Fast Ethernet Switch
14. pment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 ofthe FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation EC Conformance Declaration Class A SMC contact for these products in Europe is SMC Networks Europe Edificio Conata II Calle Fructu s Gelabert 6 8 20 4a 08970 Sant Joan Despi Barcelona Spain This information technology equipment complies with the requirements of the Council Directive 2004 108 EC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 2006 95 EC for electrical equipment used within certain voltage limits and the Amendment Directive 2006 95 EC For the evaluation of the compliance with these Directives the following standards were applied Vv RFI Emission Limit class A according to EN 55022 2006 EMC Limit class A for harmonic current emission according to EN 61000 3
15. ps links to each attached LAN segment all with conventional cabling and adapters Auto negotiation is used to select the optimal communication mode for each connection Auto sensing is used to select the optimal transmission speed for each connection With store and forward switching and flow control maximum data integrity is always maintained even under heavy loading Easy installation and reliability make this plug and play switch an ideal choice for smooth Fast Ethernet integration Green Saving Switches The Green Saving technologies are intelligent innovative algorithms that detect link status and distance to best save power while maintaining performance and stability e Power saving by Auto Detection of the number of active ports The SMC EZ1016DT SMC EZ1024DT switches will auto detect the link status and automatically cut off power at a given port during periods of idle when a port is unconnected or a PC is turned off After it detects an incoming signal it wakes up from power saving mode and operates in normal mode e Power saving by Cable length Auto Detection The SMC EZ1016DT SMC EZ1024DT switches can actively detect the presence of a shorter cable and determines the appropriate power level based on cable length so there ll be less power consumption when the link distance is shorter Features and Benefits e Save up to 59 of power usage with the SMC EZ1016DT SMC EZ1024DT switches If PCs connected to the swit
16. rtified The minimum specifications for the flexible cord are No 18 AWG not longer than 2 meters or 16 AWG Type SV or SJ 3 conductor The cord set must have a rated current capacity of at least 10A The attachment plug must be an earth grounding type with NEMA 5 15P 15 A 125 V or NEMA 6 15P 15 A 250 V configuration Denmark The supply plug must comply with Section 107 2 D1 Standard DK2 1a or DK2 5a Switzerland re plug must comply with SEV ASE U K The supply plug must comply with BS1363 3 pin 13 A and be fit ted with a 5 A fuse which complies with BS1362 The mains cord must be lt HAR gt or lt BASEC gt marked and be of type HO3VVF3GO 75 minimum SCHUKO The mains cord must be lt HAR gt or lt BASEC gt marked and be of type HO3VVF3GO 75 minimum IEC 320 receptacle Vili Veuillez lire fond l information de la s curit suivante avant d installer le Switch AVERTISSEMENT L installation et la d pose de ce groupe doivent amp tre confi s a un personnel qualifie e Ne branchez pas votre appareil sur une prise secteur alimentation lectrique lorsqu il n y a pas de connexion de mise a la terre mise a la masse e Vous devez raccorder ce groupe une sortie mise la terre mise la masse afin de respecter les normes internationales de curit e Lecoupleur d appareil le connecteur du groupe et non pas la prise murale doit respecter une configuration qui permet u
17. s from sustained and managed forests The inks used in the printing process are non toxic Purpose This guide details the hardware features of the switch including Its physical and performance related characteristics and how to install the switch Audience The guide is intended for use by network administrators who are responsible for installing and setting up network equipment consequently it assumes a basic working knowledge of LANs Local Area Networks Diese Anleitung ist f r die Benutzung durch Netzwerkadministratoren vorgesehen die f r die Installation und das einstellen von Netzwerkkomponenten verantwortlich sind sie setzt Erfahrung bei der Arbeit mit LANs Local Area Networks voraus xiii TABLE OF CONTENTS INTRODUCTION ass ee 2 Green Saving Switches Features and Benefits cccccccccuuuuueeeeeeeeeeeauuaes Front Panel EDS resident en PRONE Panels keiten Rear Panel issue nn ii INSTALLING THE SWITCH 5 Package Contents ren Selecting a Site naar IMStRUCEONS A a ae he ero cd ee ents TROUBLESHOOTING 7 Diagnosing Switch Indicators CABLES Hasen 8 Cable Spedifieationssun s seele 10BASE T 100BASE TX Pin Assignments PRODUCT SPECIFICATIONS 9 INTRODUCTION The EZ Switch 10 100 SMC EZ1016DT and SMC EZ1024DT are 16 24 port Fast Ethernet switches The 10BASE T 100BASE TX ports deliver dedicated 10 100 Mb
18. ttach the four adhesive foot pads to the bottom of the switch For rack mounting install into a standard EIA 19 inch rack using the included brackets Applying Power Plug one end of the power cord into the socket on the switch s rear panel and the other end into an appropriate electrical outlet Check the Power LED to be sure power is on Note It is not necessary to power off the switch before connecting or disconnecting any UTP cables as these actions will not disrupt the operation of other devices attached to the switch 3 Connecting PCs Connect each PC to an RJ 45 port on the switch using Category 5 or 5e shielded or unshielded twisted pair UTP or STP cable maximum length 100 meters 328 ft The EZ Switch 10 100 will support up to 16 or 24 PCs All ports on the switch support automatic MDI MDI X operation so you can use straight through cables for all network connections to PCs or servers or to other switches or hubs Note If an attached device does not support auto negotiation the data rate will be sensed automatically and the communication mode will default to half duplex 4 Cascading Switches and Other Network Devices All the ports on the switch support automatic MDI MDI X configuration for cable connections This allows you to use straight through cable to connect to other switches or hubs from any port on the switch No crossover cables or other device settings are needed See the Cable Specifications