Home
Moxa NPort 5610-16
Contents
1. TCP Socket Application Service 53 Domain Name Server domain 79 Finger protocol Finger 80 World Wide Web HTTP 119 Network news Transfer Protocol NNTP 123 Network Time Protocol 213 IPX 160 223 Reserved for future use UDP Socket Application Service 0 reserved 2 Management Utility 7 Echo 9 Discard 11 Active Users systat 13 Daytime 35 Any private printer server 39 Resource Location Protocol 42 Host name server names server 43 Whois nickname 49 Login Host Protocol Login 53 Domain Name Server domain 69 Trivial Transfer Protocol TETP 70 Gopher Protocol 79 Finger Protocol 80 World Wide Web HTTP 107 Remote Telnet Service 111 Sun Remote Procedure Call Sunrpc 119 Network news Transfer Protocol NNTP 123 Network Time protocol NTP 161 SNMP Simple Network Mail Protocol 162 SNMP Traps 213 IPX Used for IP Tunneling B 2 C SNMP Agent with MIB II amp RS 232 Like Group NPort 5600 has built in SNMP Simple Network Management Protocol agent software It supports SNMP Trap RFC1317 RS 232 like group and RFC1213 MIB II The following table lists the standard MIB II group as well as the variable implementation for NPort 5600 RFC1213 MIB II supported SNMP variables System MIB Interfaces MIB IP MIB ICMP MIB
2. Port RxCnt TxTotalcnt RxTotalCnt DSR cts DCD 1 o lo lo lo OFF OFF OFF 2 o lo o lo OFF OFF OFF 3 o lo lo lo OFF OFF OFF 4 o 0 lo lo OFF OFF OFF 5 o lo lo lo OFF OFF OFF 6 o 0 lo lo OFF OFF OFF 7 o lo lo lo OFF OFF OFF a o o o 0 OFF OFF OFF 5 36 NPort 5600 Series User s Manual Web Console Configuration Monitor Async Settings Click Async Setting under Monitor to show the run time settings for each of the four serial ports J Main Menu Monitor Async Settings Async Settings Port Baud rate Data bits Stop bits Parity FIFO RTS CTS XON XOFF DTR DSR 1 115200 8 1 None Enable ON OFF OFF 2 115200 8 1 None Enable ON OFF OFF 3 115200 8 1 None Enable ON OFF OFF 4 115200 8 1 None Enable ON OFF OFF 5 115200 8 1 None Enable ON OFF OFF 6 115200 8 1 None Enable ON OFF OFF 7 115200 8 1 None Enable on OFF OFF 8 115200 ls 1 None Enable ON OFF OFF i Change Password a Load Factory Default O Save Restart Change Password 3 Main Menu Change password LO overview ra Basic Settings Old password a Network Settings New password eo E Retype password ae Operating Settings Q Accessible IP Settings Sines C PPP User Table Settings C Auto Warning Settings J Monitor Change Password Y Load Factory Default C Save Restart Input the Old password and New password to ch
3. RJ45 Connector Female DB9 Cable Wiring 3 5 5 lt gt 3 6 lt gt 1 RJ45 Connector Male DB9 Cable Wiring 3 5 5 lt gt 2 6 lt gt 1 A 8 Male DB9 2 wire RS 485 Device 9 pins GND Data Data Female DB9 2 wire RS 485 Device 9 pins GND Data Data NPort 5600 Series User s Manual Pinouts and Cable Wiring RJ45 8 pins to Female DB25 Female DB25 RJ45 Port RJ45 Connector Male DB25 NPort 5650 i l 2 wire RS 485 Device 8 pins Cable Wiring 25 pins GND 3 7 GND Data 5 lt gt 2 Data Data 6 lt gt 8 Data RJ45 8 pins to Male DB25 RJ45 Port RJ45 Connector Male DB25 Female DB25 NPort 5650 E 2 wire RS 485 A Device 8 pins Cable Wiring 25 pins GND 3 7 GND Data 5 gt 3 Data Data 6 lt gt 8 Data Pin Assignments for DB9 and DB25 Con P Male DB9 Connector 1 DCD in DCD in 1 mel n 2 RxD in RxD in 2 CTS in A 3 TxD out TxD in 3 4 DTR out DSR in 4 5 GND GND 5 A 9 nectors in Assignments for DB9 Male and Female Connectors DB9 Female Connector O 6 DTR out 7 CTS in 8 RTS out 9 a O NPort 5600 Series User s Manual Pinouts and Cable Wiring Pin Assignments for DB25 Male and Female Connectors DB25 Male Connector DB25 Female Connector O 1 RxD in 2 14 TxD out 3 CTS in 4 RTS out 5
4. O min TCP connection is not closed due to an idle TCP connection 1 to 99 min NPort automatically closes the TCP connection if there is no TCP activity for the given time Inactivity time Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional 0 ms TCP connection is not closed due to an idle serial line 0 65535 ms NPort automatically closes TCP connection if there is no serial data activity for the given time This parameter defines the maintenances status as Closed or Listen on the TCP connection The connection is closed if there is no incoming or outgoing data through the serial port during the specific Inactivity time If the value of inactivity time is set to 0 the current TCP connection is maintained unless there s no connection close request Although the inactivity time is disabled the NPort will check the connection status between the NPort and remote host by sending keep alive packets periodically If the remote host does not respond to the packets it treats the connection as being down unintentionally NPort will then force the existing TCP connection to close ATTENTION The Inactivity time should at least be set larger than that of Force transmit timeout To prevent the unintended loss of data due to the session being disconnected it is highly recommended that this value is set large enough so that the intended data transfer is completed 5 18 NPort 5600 Serie
5. Load Default f OK X Cancel 6 16 NPort 5600 Series User s Manual Configuring NPort Administrator 10 Select a Refresh Rate the default is 3 seconds Monitor Settings Monitor Items Advanced Settings Refresh Rate Second s Auto save monitored NPort list SK X Cancel 11 Select Display warning message for new event or Play warning music for new event In the second case you must enter the path to the WAV file that you want to be played New event means that one of the 5600s in the monitor is Alive or Not Alive or has lost connection with the Monitor program Monitor Settings Monitor Items General Settings Advanced Settings Monitor and Port Monitor Message Box Setting v Display warning message for new event v Play waming music for new event C AWINDOWS Media start wav Browse gt Y OK X Cancel 6 17 NPort 5600 Series User s Manual Configuring NPort Administrator 12 Right click and select Go to start the Monitor Administrator Monitor File Function Monitor View Help F ES Exit Add Remove Go Function NPort 6 Configuration Monitor Port Monitor tis COM Mapping 00 90 E 8 OC psi Y IP Address Report L Add Target Remove Target Load Configured COM Port Ef Settings Po 13 For this example the 5 NPorts shown in the list will be monitored Administrator Monitor File Function Monito
6. NPort 5600 Series User s Manual IP Serial LIB IP Serial LIB Function Groups Server Control Port Control Input Output Data Port Status Miscellaneous Inquiry nsio_init nsio_open nsio_read nsio_Istatus nsio_break nsio_end nsio_close nsio_SetReadTimeouts nsio_data_status nsio_break_on nsio_resetserver nsio_ioctl nsio_write nsio_break_off nsio_checkalive nsio_flowctrl nsio_SetWriteTimeouts nsio_breakcount nsio_ DTR nsio_RTS nsio_lctrl nsio_baud nsio_resetport Example Program char nportip 192 168 1 10 char buffer 255 int port 1 int portid nsio_init portid nsio_open nportip port nsio_ioctl portid B9600 BIT_8 STOP_1 P_NONE sleep 1000 nsio_read port buffer 200 nsio_close portid nsio_end data buffer 255 chars 1st port port handle initial IP Serial Library 1st port nport IP 192 168 1 10 set 9600 N81 wait for 1000 ms for data read 200 bytes from port 1 close this serial port close IP Serial Library 7 3 A Pinouts and Cable Wiring In this appendix we cover the following topics Q Port Pinout Diagrams gt Ethernet Port Pinouts gt Serial Port Pinouts O Cable Wiring Diagrams gt Ethernet Cables gt Serial Cables for NPort 5610 5650 RS 232 gt Serial Cables for NPort 5630 RS 422 4 wire RS 485 gt Serial Cables for NPort 5630 2 wire RS 485 gt Serial Cables for NPort 5650 RS 422 4 wire R
7. No Yes al Data Packing a Packing length fo o 1024 4 Delimiter 1 fo Hew I Enable Delimiter 2 0 Hex F Enable a Delimiter process Do Nothing Z Processed only when Packing length is 0 a Force transmit foo 65535 ms J TCP Server Mode Local TCP port po J Command port fe a I Apply the above settings to all serial ports Local listen port will be enumerated automatically E ales Submit TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min TCP connection is not closed due to an idle TCP connection 1 to 99 min NPort automatically closes the TCP connection if there is no TCP activity for the given time After the connection is closed NPort starts listening for another host s TCP connection 5 14 NPort 5600 Series User s Manual Web Console Configuration A ATTENTION Inactivity time Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional 0 ms TCP connection is not closed due to an idle serial line 0 65535 ms NPort automatically closes the TCP connection if there is no serial data activity for the given time After the connection is closed NPort starts listening for another host s TCP connection This parameter defines the maintenances status as Closed or Listen on the TCP connection The connection is closed if there is no incoming or outgoing data through the serial port during the specific Inactivity time If the Inac
8. Initial IP Address Configuration When setting up your NPort 5600 for the first time the first thing you should do is configure the IP address This chapter introduces several methods to configure NPort s IP address Select the method that is the most convenient for you For more details about network settings see the Network Settings section from Chapter 5 Web Console Configuration This chapter includes the following sections Initializing NPort s IP Address Factory Default IP Address LCM Display recommended configuration method NPort Administration Suite lt recommended configuration method ARP Telnet Console OOOovoDO NPort 5600 Series User s Manual Initial IP Address Configuration Initializing NPort s IP Address 1 Determine whether your NPort needs to use a Static IP or Dynamic IP either DHCP or BOOTP application 2 If NPort is used in a Static IP environment you can use NPort Administration Suite ARP Web Console or Telnet Console to configure the new IP address 3 If NPort is used in a Dynamic IP environment you can use NPort Administration suite Web Console or Telnet Console to configure NPort to get an IP address dynamically with DHCP DHCP BOOTP or BOOTP A ATTENTION Consult your network administrator on how to reserve a fixed IP address for your NPort in the MAC IP mapping table when using a DHCP Server or BOOTP Server In most applications you should assign a fixed IP address to yo
9. Setting Factory Default Necessity E g 4001 None Optional Auto report period Setting Factory Default Necessity Time interval in seconds 10 Optional 5 8 NPort 5600 Series User s Manual Web Console Configuration Serial Settings Click Serial Settings located under Main Menu to display serial port settings for ports 1 and 2 NOTE Since this figure was borrowed from the manual of NPort 5200 which has only 2 RS 232 ports there are only 2 ports shown in this figure Once you have completed the hardware installation of NPort 5600 there should be either 16 or 8 ports shown in the figure depending on the model you installed The steps for changing the settings of the other ports are the same as those for Port 1 and Port 2 Serial Settings Alias Baud rate Data bits Stop bits Parity FIFO Flow ctrl Interface 115200 8 1 None Enable RTS CTS RS 232 ie 115200 fg 1 None Enable RTS CTS RS 232 3 115200 8 1 None Enable RTS CTS RS 232 y 115200 8 1 None Enable RTS CTS RS 232 y 115200 8 1 None Enable RTS CTS RS 232 y 115200 8 1 None Enable RTS CTS RS 232 3 115200 8 1 None Enable RTS CTS RS 232 y 115200 8 1 None Enable RTS CTS RS 232 A DODDUDDO To modify serial settings for a particular port click either Port 1 or Port 2 under Serial Settings located under Main Menu on the left side of the browser window Seri
10. and Progress of the search for that particular device Searching Searching for NPort Found 4 NPort s remain timeout 3 second s No Model MACAddress IP Address NPort 5650 16 00 90 E8 09 02 7A 192168 16 130 NPort 5210 00 90 E8 00 C8 3D 192 168 4 243 NPort 5210 00 90 E8 0C C9 26 192 168 4 242 NPort 5210 00 90 E8 0C C8 3E 192 168 4 241 6 6 NPort 5600 Series User s Manual Configuring NPort Administrator 3 When the search is complete the Broadcast Search window closes and the NPorts that were located are displayed in the right pane of the Administrator window For the example shown here NPort Administrator found 4 NPort Serial Device Servers on the LAN As you can see 2 of the 4 NPorts have password protection which is indicated by Lock under Status To configure one of the listed NPorts place the cursor over the row displaying that NPort s information and then right click Administrator Configuration DER File Function Configuration View Help F 2 a x Exit Search Search IP Function Configuration 4 NPort s NPort Model MAC Address IP Address 6 Configuration NPort 5210 00 90 E8 00 C9 26 192 168 4 242 Monitor NPort 5210 00 90 E8 0C C8 3E 192 168 4 241 Port Monitor NPort 5210 00 90 E8 00 C8 3D 192 168 4 243 w COM Mapping NPort 5650 16 00 90 E8 09 C2 7A 192 168 16 130 IP Address Report Description 2006 5 22 F 08 00 25 Found NPott s 4 Now 2006 5 22 FF 08 01
11. ooococccconcccocccnconcnnos 2 5 Real Time Clock ainin neea id arte 2 5 Adjustable Pull High low Resistors for the RS 485 POlTt oononcncnicnonononnnccnnncncnnnnnos 2 5 Initial IP Address Configuration ooonnmnccccnnnncccccnnnnnancccnnanenrnnnn nece rre 3 1 Imti lizing NPort s IP Address cosita taaan ds iran docto a 3 2 Factory Default IP Address ooooooonncnncnonincconcnnonononannnnononacnncnnonocncn nono none rn cnn nena canon nora ni e oaio 3 2 EENE DIE a Fe Daa iaa cida ds hate id 3 2 NPort Administration Suite 00 ce cececssesccsseceeecnecsecseeecaecsessecsessessecnesseceaseeesaeceesaeeneeaes 3 5 ARPA A a OI ie ri 3 5 Telnet Console oia iia 3 6 Choosing the Proper Operation Mode oooommnccconnnnncccnnccncnnnannnconenanncnnnos 4 1 OVIVI Wisconsin loas 4 2 Real COM Mode ic ccaiassacierd sticeiaid ale nave d hice cute Aids Raver a Antares 4 2 NARA OS 4 3 TCP Chen Modest tips 4 4 UDP Modernitas dote 4 4 Parr Connection Modena ii oo dE e a 4 4 Reverse Telnet Modenos errok eater tocante lides 4 5 Disabled Modernitas 4 5 REC2217 Modena aisla 4 5 PPP Mod annain nae eae kei Aina Ania aaa niin Ghats 4 6 Web Console Configuration ccccseseeeeesseeeeeeeseeeeeeeeeeeeeeeeenseeneeeeneeene 5 1 Opening Your Bro WSL viril cb 5 2 Basic Settings cadera Ati eee die aa A Aoi 5 3 Network Settings osito seh asco eat ita 5 5 Serial SEM ii al 5 9 Operating Settin ess ice co ollo aaa 5 11 Real COM Mode cucicionoss tio inid linia
12. 1 Delimiter i 2 Strip Delimiter Do Nothing When Delimiter 1 or Delimiter 2 is selected the data will be transmitted when an additional byte for Delimiter 1 or an additional 2 bytes for Delimiter 2 of data is received after receiving the Delimiter When Strip Delimiter is selected when the Delimiter is received the Delimiter is deleted i e stripped and the remaining data is transmitted When Do nothing is selected the data will be transmitted when the Delimiter is received 5 23 NPort 5600 Series User s Manual Web Console Configuration A ATTENTION Delimiter 2 is optional If left blank then Delimiter 1 alone trips clearing of the buffer If the size of the serial data received is greater than 1 KB the NPort will automatically pack the data and send it to the Ethernet However to use the delimiter function you must at least enable Delimiter 1 If Delimiter 1 is left blank and Delimiter 2 is enabled the delimiter function will not work properly Force transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional 0 Disable the force transmit timeout 1 to 65535 Forces the NPort s TCP IP protocol software to try to pack serial data received during the specified time into the same data frame This parameter defines the time interval during which NPort fetches the serial data from its internal buffer If data is incoming through the serial port NPort stor
13. 1 G Mus ad A a ort d A 16 3 na None 8 IE IP Address Report NPort 5650 16 192 168 16 130 Enable FIFO Ena 9600 None 8 1 7 NPort 5650 16 192 168 16 130 Disable FIFO Ena 9600 None 8 1 8 NPort 5650 16 192 168 16 130 FIFO Ena 9600 None 8 1 3 NPort 5650 16 19216816130 ESP COM Settings FIFO Ena 9600 None 8 1 10 NPort 565016 18216816130 E AppyC FIFO Ena 9600 None 8 1 11 NPort 5650 16 19216816 130 pply Change FIFO Ena 3600 None 8 1 12 NPort 5650 16 192 168 16 130 Discard Change FIFO Ena 9600 None 8 1 13 NPort 5650 16 192 168 16 130 FIFO Ena 9600 None 8 1 14 NPort 5650 16 192 168 16 130 Export COM Mapping FIFO Ena 9600 None 8 1 15 NPort 5650 16 19216816130 rot COM Mappi FIFO Ena 9600 None 8 1 16 NPort 5650 16 192 168 16 130 WPO TERE FIFO Ena 9600 None 8 1 Select the COM No COM ports that are In use or Assigned will also be indicated in this drop down list If you select multiple serial ports or multiple NPorts remember to check the Auto Enumerating function to use the COM No you select as the first COM No x x Port Number 2 Port s Selected 1st port is Port 1 Port Number 2 Pott s Selected 1st port is Port 1 Basic Settings Advanced Settings Serial Parameters Basic Settings Advanced Settings Serial Parameters COM Number COM1 current assigned A COM Number CO Auto Enumerating C
14. After choosing the proper operation mode in this chapter refer to Chapter 5 for detailed configuration parameter definitions The following topics are covered in this chapter Overview Real COM Mode TCP Server Mode TCP Client Mode UDP Mode Pair Connection Mode Reverse Telnet Mode Disabled Mode RFC 2217 Mode PPP Mode PEODCDOLDOODDO NPort 5600 Series User s Manual Choosing the proper Operation Mode Overview NPort Device Servers network enable traditional RS 232 422 485 devices in which a Device Server is a tiny computer equipped with a CPU real time OS and TCP IP protocols that can bi directionally translate data between the serial and Ethernet formats Your computer can access manage and configure remote facilities and equipment over the Internet from anywhere in the world Traditional SCADA and data collection systems rely on serial prots RS 232 422 485 to collect data from various kinds of instruments Since NPort Serial Device Servers network enable instruments equipped with an RS 232 422 485 communication port your SCADA and data collection system will be able to access all instruments connected to a standard TCP IP network regardless of whether the devices are used locally or at a remote site NPort is an external IP based network device that allows you to expand the number of serial ports for a host computer on demand As long as your host computer supports the TCP IP protocol you won t be limited by t
15. Enable or Disable Enable Required A ATTENTION If you disable both the Web Console and Telnet Console you can still use the LCM Display to configure NPort locally or Windows Administrator to configure NPort either locally or remotely over the network Network Settings Network Settings IP address 192 168 127 254 Netmask 255 255 0 0 Gateway 255 255 255 255 IP configuration Stic y DNS server 1 DNS server 2 SNMP Setting SNMP Enable Disable Community name public Contact Location IP Address report Auto report to IP E AS Auto report to TCP port faooz Auto report period 10 seconds Submit You must assign a valid IP address to NPort 5600 before it will work in your network environment Your network system administrator should provide you with an IP address and related settings for your network The IP address must be unique within the network otherwise NPort 5600 will not have a valid connection to the network First time users can refer to Chapter 3 Initial IP Address Configuration for more information You can choose from four possible IP Configuration modes Static DHCP DHCP BOOTP and BOOTP located under the web console screen s IP configuration drop down box 5 5 NPort 5600 Series User s Manual Web Console Configuration Method Function Definition Static User defined IP address
16. Netmask Gateway DHCP DHCP Server assigned IP address Netmask Gateway DNS and Time Server DHCP BOOTP DHCP Server assigned IP address Netmask Gateway DNS and Time Server or BOOTP Server assigned IP address if the DHCP Server does not respond BOOTP BOOTP Server assigned IP address IP Address Setting Factory Default Necessity E g 192 168 1 1 IP addresses of the form 192 168 127 254 Required x x x 0 and x x x 255 are invalid An IP address is a number assigned to a network device such as a computer as a permanent address on the network Computers use the IP address to identify and talk to each other over the network Choose a proper IP address which is unique and valid in your network environment Netmask Setting Factory Default Necessity E g 255 255 255 0 255 255 255 0 Required A subnet mask represents all the network hosts at one geographic location in one building or on the same local area network When a packet is sent out over the network the NPort will use the subnet mask to check if the desired TCP IP host specified in the packet is on the local network segment If the address is on the same network segment as the NPort a connection is established directly from the NPort Otherwise the connection is established through the given default gateway Gateway Setting Factory Default Necessity E g 192 168 1 1 None Optional A gateway is
17. None RTS CTS DTR DSR Xon Xoff RTS CTS Required FIFO Setting Factory Default Necessity Enable Disable Enable Required NPort s serial ports provide a 16 byte FIFO both in the Tx and Rx directions Disable the FIFO setting when your serial device does not have a FIFO to prevent data loss during communication Interface Setting Factory Default Necessity NPort 5610 16 8 RS 232 only RS 232 only Required NPort 5630 16 8 RS 422 485 only 4 wire RS 485 Required NPort 5650 16 8 RS 232 Required 5 10 NPort 5600 Series User s Manual Web Console Configuration Operating Settings 4 Operating Settings Operating Settings Port Operating mode EEN Delimiter 1 Delimiter 2 Delimiter process Force transmit o 0 Disable 0 Disable Do Nothing lo RFC 2217 Mode TCP alive check time 7 Inactivity time o TCP Compress No PPP Mode Incoming PAP Check No a Source IP address E Destination IP address G IP netmask 255 255 255 255 Modem initial string AT Inactivity time o TCP Compress No y A 3 PPP Mode Incoming PAP Check No G Source IP address m Destination IP address a IP netmask 255 255 255 255 Modem initial string AT meee Inactivity time o TCP Compress No Incoming PAP Check No PPP Mode Source IP address Click Operating Settings located under Main Menu to display the operating settings for all of NPort s
18. Obtain the NPort s MAC address from the label on its bottom panel 3 Execute the arp s command from your computer s MS DOS prompt by typing arp s 192 168 200 100 00 90 E8 xx xx xx This is where 192 168 200 100 is the new IP address and 00 90 E8 xx xx xx is the MAC address for your NPort You will need to change both numbers as described above in points and 2 4 Next execute a special Telnet command by typing telnet 192 168 200 100 6000 After issuing this command a Connect failed message will appear as shown here After the NPort reboots its IP address should be updated to the new address and you can reconnect using Telnet Web or Administrator to check that the update was successful Connect failed x Could not open a connection to 192 168 200 100 Telnet Console Depending on how your computer and network are configured you may find it convenient to use network access to set up your NPort s IP address This can be done using the Telnet program A ATTENTION Figures in this section will use 5610 8 as an example From the Windows desktop click Start and then select Run 2 Typetelnet 192 168 127 254 use the correct IP address if different from the default in the Open text input box and then click OK Run 12 1xj Type the name of a program folder document or Intemet 5 resource and Windows will open it for you Open telnet 192 168 127 254 y Cancel Browse 3 When the Teln
19. You will then be able to import this configuration file to another host and use the same COM Mapping settings in the other host Administrator COM Mapping Eek File Function COM Mapping View Help a ery Exit Add Remove Appi Configure Function COM Mapping 16 com z ICO SO O E TEC OI RR Configuration NPort 5650 16 3 i COM i Pefom p None Monitor NPort 5650 16 182 168 16 130 COMTI HiPerform Sx Add Target Port Monitor NPort 5650 16 192 168 16 130 COM12 Hi Pertorm 2S Remove Target COM Mapping NPort 5650 16 192168 16 130 COM13 Hi Perform NPort 5650 16 192168 16130 E NPort 5650 16 192168 16 130 COM22 HiPerform Disable NPort 5850 16 192168 16 130 COM23 HiPerform NPort 5650 16 19216816130 9 COM24 HiPertorm EY COM Settings NPort 5650 16 192168 16 130 10 COM25 HiPerform EJ Anny C NPort 5650 16 19216816130 11 COM26 HiPeronm 400 Change B NPort 5650 16 192 168 16 130 12 COM27 Hi Perform Discard Change B 1 NPort 5650 16 192 168 168 130 13 COM28 HiPerform E NPort 5850 16 19216816130 14 COM29 HiPerform Export COM Mapping NPort 5650 16 19216816130 15 COM30 HiPerform Y ImportCOM Mapping B 1 NPort 5650 16 192 168 168 130 16 COM31 HiPerforme gt COM21 Hi Perform 2 3 4 XP IP Address Report NPort 5650 16 192168 16 130 5 COM14 HiPerform Enable 7 8 6 24 NPort 5600 Series User s Manual Configuring NPort Administrator Off line COM Mapping 1 Add a target by entering the IP
20. 485 Device 8 pins Cable Wiring 9 pins TxD 2 gt 8 RxD GND 3 5 GND TxD 4 gt 2 RxD RxD 5 lt 3 TxD 6 lt 1 TxD RxD RJ45 8 pins to Male DB9 RJ45 Port RJ45 Connector Male DB9 Female DB9 RS 422 NPort 5650 E k 4 wire RS 485 Device 8 pins Cable Wiring 9 pins TxD 2 gt 7 RxD GND 3 5 GND TxD 4 gt 3 RxD RxD 5 lt 2 TxD 6 lt 1 RxD TxD A 7 NPort 5600 Series User s Manual Pinouts and Cable Wiring RJ45 8 pins to Female DB25 RJ45 Port NPort 5650 8 pins TxD GND TxD RxD RxD Female DB25 RJ45 8 pins to Male DB25 RJ45 Port NPort 5650 8 pins TxD GND TxD RxD RxD RJ45 Connector EJ Cable Wiring 2 gt 5 3 7 4 gt 3 5 lt 2 6 lt 8 RJ45 Connector Male DB25 EJ Cable Wiring 2 gt 4 3 7 4 gt 2 5 lt 3 6 lt 8 Male DB25 RS 422 4 wire RS 485 Device 25 pins RxD GND RxD TxD TxD Female DB25 RS 422 4 wire RS 485 Device 25 pins RxD GND RxD TxD TxD Serial Cables for NPort 5650 2 wire RS 485 RJ45 8 pins to Female DB9 RJ45 Port NPort 5650 8 pins GND Data Data RJ45 8 pins to Male DB9 RJ45 Port NPort 5650 8 pins GND Data Data
21. 5210 0x80000312 0x0332 NPort 5232 0x80000312 0x1332 NPort 52321 0x80005610 0x5618 NPort 5610 8 0x80005610 0x5613 NPort 5610 16 0x80005610 0x5638 NPort 5630 8 0x80005610 0x5633 NPort 5630 16 0x80005610 0x5658 NPort 5650 8 0x80005610 0x5653 NPort 5650 16
22. 5600 should send that series of characters during a time interval less than the Force transmit timeout for NPort 5600 and the total length of data must be less than or equal to NPort 5600 s internal buffer size The serial communication buffer size for NPort 5600 is 1 KB per port PPP Mode Operating Settings Port 1 Operation mode PPP Mode pd Inactivity time 0 0 65535 ms TCP Compress No y Incoming PAP Check No y Source IP address Destination IP address IP netmask 255 255 255 255 Modem initial string AT I Apply the above settings to all serial ports Submit J Load Factory Default 0 Save Restart PPP provides standard PPP service for dial in Inactivity time Setting Factory Default Necessity 0 to 65535 ms 0 Optional Idle time setting for auto disconnection 0 min means it will never disconnect TCP IP compression Setting Factory Default Necessity Yes or No No Optional Depends on whether the remote user s application requests compression 5 30 NPort 5600 Series User s Manual Web Console Configuration Incoming PAP check Setting Factory Default Necessity Yes or No No Optional Depends on whether the remote user s application requests PAP check Source IP address Setting Factory Default Necessity Source IP address Required Destination IP address Setting Facto
23. Add the target to which you would like to map COM ports Administrator COM Mapping File Function COM Mapping View Help F 2 El E Exit Add Remo Apply Cor Function COM Mapping 0 COM IP Address Parameter Configuration Monitor zZ Port Monitor 2 Aad Tongo COM Mapping X IP Address Report 4 The NPort list that appears is the list generated by the previous Broadcast Search Select the NPort to which you would like to map COM ports Select From List Rescan Select All Clear All No Mode MAC Address IPAddress 1 NPort 5650 16 00 90 E8 09 C2 7A 192 168 16 130 O2 NPort 5210 00 90 E8 0C C8 3E 192 168 4 241 a NPort 5210 00 90 8 0C C9 26 192 168 4 242 Os NPort 5210 00 90 E8 0C C8 3D 192 168 4 243 6 21 NPort 5600 Series User s Manual Configuring NPort Administrator 5 Select COM Setting to modify COM No default setting etc Administrator COM Mapping Eile Function COM Mapping View Help F 2 a El ES Exit Add Remove Apply Configure Function NPort COM Mapping 16 COM No Model IPAddress Por COMPot Mode Paametes 1 192 168 16 130 a Configuration NPort 5650 16 LiPerfomance FIFO Ena 9600 None 8 1 Monitor 2 NPort 5650 16 192 168 16 130 22 Add Target FIFO Ena 9600 None 8 1 E Port Monitor 3 NPort 5650 16 192 168 16 130 FIFO Ena 9600 None 8
24. Assign IP Address 6 13 NPort 5600 Series User s Manual Configuring NPort Administrator 2 The Import Configuration function is used to import an NPort configuration from a file into one or more of the same model NPort To import a configuration first select the target servers use the left mouse button to select servers simply hold down the Ctrl key when selecting the second third etc NPort Administrator Configuration File Function Configuration View Help F 2 Ey Exit Search SearchIP Locate Configure Web Function Configuration 4 NPort s NPort No Model MACAddress IP Address Status Configuration 1 NPort 5210 00 30 E8 00 C9 26 192 168 4 242 Monitor 2 NPort 5210 00 90 E8 0C C8 3E 192 168 4 241 Lock Port Monitor 3 NPort 5210 00 90 8 0C C8 3D 1921684243 rd COM Mapping TI NPort 5650 16 00 90 E8 09 C IP Address Report Broadcast Search Specify by IP Address Locate Unlock Configure Web Upgrade Firmware DEORE BI Export Configuration Import Configuration Message Log 2 Monitor Log 0 Assign IP Address No Time Description ATTENTION You can simultaneously import the same configuration file into multiple NPort 5600s that are of the same model To select multiple NPort 5600s hold down the Ctrl key when selecting an additional NPort 5600 or hold down the Shift key to select a block of NPort 5600s Monitor There are two methods
25. Begin Empty Optional E g Begin 192 168 1 11 End Empty End 192 168 1 20 Port 4001 5 24 NPort 5600 Series User s Manual Web Console Configuration Local listen port Setting Factory Default Necessity 1 to 65535 4001 Required The UDP port that NPort listens to and that other devices must use to contact NPort To avoid conflicts with well known UDP ports the default is set to 4001 Pair Connection Mode Pair Connection Mode employs two NPort 5600 device servers in tandem and can be used to remove the 15 meter distance limitation imposed by the RS 232 interface One NPort 5600 is connected from its RS 232 port to the COM port of a PC or other type of computer such as hand held PDAs that have a serial port and the serial device is connected to the RS 232 port of the other NPort 5600 The two NPort 5600 device servers are then connected to each other with a cross over Ethernet cable both are connected to the same LAN or in a more advanced setup they communicate with each other over a WAN i e through one or more routers Pair Connection Mode transparently transfers both data and modem control signals although it cannot transmit the DCD signal between the two NPorts Pair Connection Master Mode When using Pair Connection Mode you must select Pair Connection Master Mode for the Operation mode of one of the NPort 5600 device servers In effect this NPort 5600 will be acting as a TCP client Opera
26. Enter IP address 255 255 255 255 e g 192 168 1 1 255 255 255 255 Hosts on a specific subnet can access the NPort Enter IP address 255 255 255 0 e g 192 168 1 0 255 255 255 0 Any host can access the NPort Disable this function Refer to the following table for more details about the configuration example Allowable Hosts Input format Any host Disable 192 168 1 120 192 168 1 120 255 255 255 255 192 168 1 1 to 192 168 1 254 192 168 1 0 255 255 255 0 192 168 0 1 to 192 168 255 254 192 168 0 0 255 255 0 0 192 168 1 1 to 192 168 1 126 192 168 1 0 255 255 255 128 192 168 1 129 to 192 168 1 254 192 168 1 128 255 255 255 128 PPP User Table PPP User Table Settings Index User Name Password wN e a un 5 32 NPort 5600 Series User s Manual Web Console Configuration Auto Warning Settings Auto warning E mail and SNMP Trap MO xm I Main Menu Auto warning Email and SNMP trap Q Overview Basic Settings Mail server O Network Settings Mail server aC i E Sars H a TS I my server requires authentication J Operating Settings A p 5 User name F U Accessible IP Settings Hal PPP Us
27. Female DB9 Female DB25 RS 422 4 wire RS 485 Device 25 pins RxD RxD TxD TxD GND Serial Cables for NPort 5630 2 wire RS 485 RJ45 Port RJ45 Connector Female DB9 Male DB9 2 2 wire RS 485 NPort 5630 E il Ki Dede 8 pins Cable Wiring 9 pins Data 5 gt 3 Data Data 6 lt gt 1 Data GND 7 7 GND RJ45 8 pins to Male DB9 RJ45 Port RJ45 Connector Male DB9 Female DB9 E ARI 2 wire RS 485 NPort S630 al Ki Device 8 pins Cable Wiring 9 pins Data 5 gt 2 Data Data 6 lt gt 1 Data GND 7 8 GND RJ45 8 pins to Female DB25 RJ45 Port RJ45 Connector Female DB25 Male AN DB25 NPort 5630 l i 2 wire RS 485 NW Device 8 pins Cable Wiring 25 pins Data 5 lt gt 2 Data Data 6 lt gt 8 Data GND 7 4 GND A 6 NPort 5600 Series User s Manual Pinouts and Cable Wiring RJ45 8 pins to Male DB25 RJ45 Port RJ45 Connector Male DB25 Female DB25 NPort 5630 ET 2 wire RS 485 Device 8 pins Cable Wiring 25 pins Data 5 lt gt 3 Data Data 6 lt gt 8 Data GND 7 _ 5 GND Serial Cables for NPort 5650 RS 422 4 wire RS 485 RJ45 8 pins to Female DB9 RJ45 Port RJ45 Connector Female DB9 Male DB9 EN oA RS 422 NES 70 J ll lt 4 wire RS
28. Fiber Model Real Time Clock Adjustable Termination Resistor for the RS 485 Port VVVVV VV V NPort 5600 Series User s Manual Getting Started Panel Layout The following figures depict the front and rear panels of the NPort 5600 series Front panel of NPort 5600 series NPort 561016 Rear panel of NPort 5600 series AC Power e AC POWER 100 240V 47 63Hz Serial ports 9 10 11 12 13 14 15 16 1 2 3 4 5 6 A 8 LAL AG AL A Rear panel of NPort 5600 series DC Power Serial port keble 2 3 asera pO Ws peaa ECO Oo eg ge e ew oe OA Rear panel of NPort 5650 Fiber model Pipe Serial ports 9 10 11 12 13 14 15 16 UU 1 2 3 4 5 6 7 8 E Link e FEFEFE VEA VA E FEFFE gt aan AC POWER 100 240V 47 63Hz Reset Button Press the Reset button continuously for 5 sec to load factory defaults Use a pointed object such as a straightened paper clip or toothpick to press the reset button This will cause the Ready LED to blink on and off The factory defaults will be loaded once the Ready LED stops blinking after about 5 seconds At this point you should release the reset button 2 2 NPort 5600 Series User s Manual Getting Started Connecting the Hardware This section describes how to connect NPort 5600 Series to serial devices for first time testing
29. NPort driver will work faster with PurgeComm The Serial Parameter settings shown here are the default settings when the NPort is powered on However the program can redefine the serial parameters to different values after the program opens the port via Win 32 API COM Port Settings E xj Port Number 2 Port s Selected 1st port is Port 1 Basic Settings Advanced Settings Serial Parameters Baud Rate pe Parity None Data Bits 8 oa Stop Bits 1 Flow control None V Apply All Selected Ports Y OK X Cancel 6 23 NPort 5600 Series User s Manual Configuring NPort Administrator 7 After setting the COM Mapping remember to select Apply Change to save the information in the host system registry The host computer will not have the ability to use the COM port until after Apply Change is selected Administrator COM Mapping File Function COM Mapping View Help A A nde B off Exit Add Remove Apply Configure Function COM Mapping 16 COM ee a NPort 5650 16 192168 16 130 COMTI HiPe Py Add Target NPort 5850 16 192 168 16 130 COM12 HiPe COM Mapping NPort 565018 190168 18130 o eee ort j A 1b rPe ID Arase Napon NPort 5650 16 192 168 16 130 COM21 HiPe Enable NPort 5650 16 192168 16 130 COM22 HiPe Disable NPort 5650 16 192168 16 130 COM23 HiPe NPort 5650 16 192168 16 130 COM24 HiPe Sf COM Settings NPort 5650 16 192 168 16 130 10 COM25 HiPe m NPort 5650 16 192168 16 130 11 COM26 H
30. SNMP MIB UdpInDatagrams tcpRtoAlgorithm snmpInPkts UdpNoPorts tcpRtoMin snmpOutPkts UdpInErrors tcpRtoMax snmpInBad Versions UdpOutDatagrams tcpMaxConn snmpInBadCommunityNames UdpLocalAddress tcpActiveOpens snmpInASNParseErrs UdpLocalPort tcpPassiveOpens snmpInTooBigs tcpAttempFails snmpInNoSuchNames Address Translation MIB __ tcpEstabResets snmpInBad Values AtlfIndex tcpCurrEstab snmpInReadOnlys AtPhysAddress tcpInSegs snmpInGenErrs AtNetAddress tcpOutSegs snmpInTotalReq Vars Address Translation MIB TCP MIB SNMP MIB AtNetAddress tcpRetransSegs snmpInTotalSet Vars tcpConnState snmpInGetRequests tcpConnLocalAddress snmpInGetNexts tcpConnLocalPort snmpInSetRequests tcpConnRemAddress snmpInGetResponses tcpConnRemPort snmpInTraps tcpInErrs snmpOutTooBigs tcpOutRsts snmpOutNoSuchNames snmpOutBad Values snmpOutGenErrs snmpOutGetRequests snmpOutGetNexts snmpOutSetRequests C 2 NPort 5600 Series User s Manual SNMP Agent with MIB II amp RS 232 Like Group TCP MIB SNMP MIB snmpOutGetResponses Address Translation MIB snmpOutTraps snmpEnableAuthenTraps RFC1317 RS 232 MIB objects Generic RS 232 like Group O General Port a Asynchronous rs232Number rs232PortTable rs232AsyncPortTable rs232PortEntry rs232AsyncPortEntry rs232PortIndex rs232AsyncPortIndex rs232PortType rs232AsyncPortBits rs232PortInSigNumber rs232AsyncPortStopBits rs232Port
31. SysDescr itNumber ipForwarding IcmpInMsgs SysObjectID ifIndex ipDefaultTTL IcmpInErrors SysUpTime ifDescr ipInreceives IcmpInDestUnreachs SysContact ifType 1pInHdrErrors IcmpInTimeExcds SysName ifMtu ipInAddrErrors IcmpInParmProbs SysLocation ifSpeed ipForwDatagrams IcmpInSrcQuenchs SysServices ifPhysAddress ipInUnknownProtos IcmpInRedirects ifAdminStatus ipInDiscards IcmpInEchos ifOperStatus ipInDelivers IcmpInEchoReps ifLastChange ipOutRequests IcmpInTimestamps ifInOctets ipOutDiscards IcmpTimestampReps ifInUcastPkts ipOutNoRoutes IcmpInAddrMasks ifInNUcastPkts ipReasmTimeout IcmpOutMsgs ifInDiscards ipReasmReqds IcmpOutErrors ifInErrors ipReasmOKs IcmpOutDestUnreachs ifInUnknownProtos ipReasmFails IcmpOutTimeExcds ifOutOctets ipFragOKs IcmpOutParmProbs ifOutUcastPkts ipFragFails IcmpOutSrcQuenchs ifOutNUcastPkts ipFragCreates IcmpOutRedirects ifOutDiscards ipAdEntAddr IcmpOutEchos ifOutErrors ipAdEntIfIndex IcmpOutEchoReps NPort 5600 Series User s Manual SNMP Agent with MIB II amp RS 232 Like Group System MIB Interfaces MIB IP MIB ICMP MIB ifOutQLen ipAdEntNetMask IcmpOutTimestamps ifSpecific ipAdEntBcastAddr IcmpOutTimestampReps ipAdEntReasmMaxSize IcmpOutAddrMasks IpNetToMedialfIndex IcmpOutAddrMaskReps IpNetToMediaPhysAddress IpNetToMediaNetAddress IpNetToMediaType IpRoutingDiscards UDP MIB TCP MIB
32. a network gateway that acts as an entrance to another network Usually the computers that control traffic within the network or at the local Internet service provider are gateway nodes NPort needs to know the IP address of the default gateway computer in order to communicate with the hosts outside the local network environment For correct gateway IP address information consult the network administrator IP Configuration Setting Factory Default Necessity Static Static Required DHCP DHCP BOOTP BOOTP 5 6 NPort 5600 Series User s Manual Web Console Configuration A ATTENTION In Dynamic IP environments the firmware will retry 3 times every 30 seconds until network settings are assigned by the DHCP or BOOTP server The Timeout for each try increases from 1 second to 3 seconds to 5 seconds If the DHCP BOOTP Server is unavailable the firmware will use the default IP address 192 168 127 254 Netmask and Gateway for IP settings DNS server 1 DNS server 2 Setting Factory Default Necessity E g 192 168 1 1 None Optional IP addresses of the form x x x 0 and x x x 255 are invalid When the user wants to visit a particular website the computer asks a Domain Name System DNS server for the website s correct IP address and the computer users the response to connect to the web server DNS is the way that Internet domain names are identified and translated into IP addresses A domain
33. address and selecting the Model Name without physically connecting the NPort to the network Add NPort gt Select From List No Model MACAddess IP Address 8 Input Manually IP Address 192 168 16 130 Model NPort 5650 16 Ports 16 Port s J OK X Cancel Administrator COM Mapping File Function COM Mapping View Help x COM Mapping 16 com o Configuration NPort 5650 16 192 168 16 130 Hi Performance FIFO Ena 9600 None 8 1 Monitor NPort 5650 16 192 168 16 130 HiPerformance FIFO Ena 9600 None 8 1 Port Monitor NPort 5650 16 192 168 16 130 Hi Performance FIFO Ena 9600 None 8 1 ri COM Mapping NPort 5650 16 192 168 16 130 Hi Performance FIFO Ena 9600 None 8 1 XP IP Address Report NPort 5650 16 192 168 16 130 Hi Performance FIFO Ena 9600 None NPort 5650 16 192 168 16 130 Hi Performance FIFO Ena 9600 None NPort 5650 16 192 168 16 130 Hi Performance FIFO Ena 9600 None NPort 5650 16 192 168 16 130 Hi Performance FIFO Ena 9600 None NPort 5650 16 192 168 16 130 Hi Performance FIFO Ena 9600 None NPort 5650 16 192 168 16 130 Hi Performance FIFO Ena 9600 None NPort 5650 16 192 168 16 130 Hi Performance FIFO Ena 9600 None NPort 5650 16 192 168 16 130 Hi Performance FIFO Ena 9600 None NPort 5650 16 192 168 16 130 Hi Performance FIFO Ena 9600 None 8 1 NPort 5650 16 192 168 16 130 Hi Performance FIFO Ena 9600 None 8 1 NPort 5650 1
34. and encode Compared to using only one TCP port to control serial communication such as REC 2217 IP Serial Library uses a command port to communicate with NPort in user s program IP Serial Library not only runs with excellent efficiency but also runs without any decode or encode problems How to install IP Serial Library IP Serial Lib comes with the NPort Administration Suite Refer to the IPSerial directory for more detail about the function definitions EN NPortAdminSuite File Edit View Favorites Tools Help Back gt al A search E Folders History fe E XxX A Edy address NPortAdminSuite Folders Se 3 1 Gs Desktop i 4 30 2003 10 27 AM EA My Documents Lino il 4425 2003 TO 29 My Pictures NPortAdminSuite File Folder 4 28 2003 4 01 PM 8 my Computer ToDo SOS TTS A H 6 Local Disk C VERSION sa unins000 11KB DAT File 4 28 2003 4 01 PM E TEST D Text Document E uninsO00 85KB Application 1 8 2003 12 00 AM E pian oe Settings Modified 3 17 2003 3 23 AM El version 1KB Text Document 3 17 2003 3 23 AM E a Personal Data Size 110 bytes 5 Program Files H O Accessories C Common Files E ComPlus Applications J Internet Explorer im microsoft Frontpage 2 Microsoft Office E Microsoft Visual Studio G MWSnap a NetMeeting fea NPortAdminSuite 2 Outlook Express 2 Windows Media Player H E Windows NT m WINNT Attributes normal EE El
35. covered in this chapter Overview Q Installing NPort Administrator Q Configuration gt Broadcast Search gt Unlock Password Protection gt Configuring NPort 5600 gt Upgrading Firmware gt Export Import Monitor Port Monitor COM Mapping gt On line COM Mapping gt Off line COM Mapping A IP Location Ooo NPort 5600 Series User s Manual Configuring NPort Administrator Overview NPort Administrator lets you easily install and configure your NPort 5600 Series product over the network NPort Administrator provides five function groups that ease the installation process allow off line COM mapping and provide monitoring and IP location server functions NPort Administrator is an integrated software suite that bundles NPort Administrator and the IP Serial Library and provides everything you need to remotely manage monitor and modify your NPort from a remote location Installing NPort Administrator 1 Once the Setup program starts running click Next when the Welcome window opens to proceed with the installation 1 Setup NPort Administration Suite Welcome to the NPort Administration Suite Setup Wizard This will install NPort Administration Suite Yer1 1 on your computer It is recommended that you close all other applications before continuing Click Next to continue or Cancel to exit Setup A Setup NPort Administration Suite j 1504 x Select Destination Dir
36. droit dois dis deis cade 5 11 TEP Server Mode s cs cssucssieesveissssensieddssessbesssvscassstyscsssroavtedssdussesssouseuseeesesovctsecoeees 5 14 TEP Clients MO erste cice tests sck cet eseae a 5 18 Chapter 6 Chapter 7 Appendix A Appendix B UDP Mode sois ati 5 23 Pair Connection Mode oicicscccscssssccecssee eiiie E EREE RER sends 5 25 Reverse Telnet Modest its ia 5 27 Disabled Mode aci ie aa Liar O 5 28 REC2217 Moderato dai 5 28 PPPModeiiot ii 5 30 Accessible TP Seting mii iria r pa 5 31 PPP User Table ruido 5 32 AUtOo Wade viciado poate ee 5 33 Auto warning E mail and SNMP TraP cocconccnonncnnoninnoncnnncnncnncnncnnonononorononnonccnncnnon 5 33 Event TV Pe ra a ren 5 34 Mod 5 36 Monitor LIMe cular did add dida 5 36 Monitor ASC a 5 36 Monitor ASync Settii i s camion its 5 37 Change Password dennen nine 5 37 Load Factory Defaults rrr edesten r tira eii 5 38 Configuring NPort AdMiniStratOF oooommccccnnnnnncnnnnnsnccnnnnnennnnnnccrnnnanannnnns 6 1 O VEVIE Wii iii elias ds aca nebucues te diia Da ill dada 6 2 Installing NPort Administrator eee eeecseeeecseeneeeecsseeccssecaeesecseesecnaeeeesaecaesaecseesesnaeeeeeas 6 2 Conf suration a 6 5 Broadcast Search sss sissies iia ie 6 6 Unlock Password Protection ccccesceesseesceesceeeceseeeseeeeeseceseeeaecaecaaecaeeeaeeeneeeneees 6 7 Configuring NPort S600 aio fies etico salsas nice 6 10 Upgr ding Firmware enoe neen reip Tbe E S EE a EES 6 12 Export Impor
37. for all signals RS 422 485 16 8 RJ45 8 pin RS 422 Tx Tx Rx Rx GND RS 485 2 wire Data Data GND RS 485 4 wire Tx Tx Rx Rx GND 15 KV ESD for all signals ADDC Automatic Data Direction Control RS 232 422 485 16 8 RJ45 8 pin RS 232 TxD RxD RTS CTS DTR DSR DCD GND RS 422 Tx Tx Rx Rx GND RS 485 2 wire Data Data GND RS 485 4 wire Tx Tx Rx Rx GND 15 KV ESD for all signals RS 485 Data Direction ADDC Automatic Data Direction Control 4 KV Burst EFT EN61000 4 4 2 KV Surge EN61000 4 5 NPort 5600 Series User s Manual Introduction Advanced Built in Features HMI Buzzer Real Time Clock Watch Dog Timer LCM display with four push buttons Serial Communication Parameters Parity Data Bits Stop Bit Flow Control Transmission Speed Software Features Protocols Utilities OS Driver Support Configuration Power Requirements Power Input Power Consumption Mechanical Material Dimensions W x H x D None Even Odd Space Mark 5 6 7 8 15 2 RTS CTS XON XOFF DSR DTR Excluded NPort 5630 50 bps to 921 6 Kbps ICMP IP TCP UDP DHCP BOOTP Telnet DNS SNMP HTTP SMTP SNTP Rtelnet ARP PPP RFC2217 NPort Administrator for Windows 98 ME NT 2000 X P 2003 Vista 2008 XP x64 2003 x64 Vista x64 2008 x64 Real COM drivers for Windows 95 98 ME NT 2000 XP Vista 2008 XP x64 2003 2003 x64 Vista x64 2008 x64 Real
38. lt d gt lt u gt lt m gt lt q gt SNMP SNMP SNMP SNMP Auto Auto Auto View Back Quit community contact location IP report to IP IP report to TCP port IP report period settings to main menu Key in your selection 1 IP address 192 168 127 254 Set IP address success any key to continue 8 Type m or M and then press Enter to return to the main menu lt lt Main Menu gt Network settings gt gt IP address Netmask Gateway IP configuration DNS server 1 DNS server 2 i gt lt 2 lt 3 lt 4 lt 5 gt lt 6 gt lt lt 8 gt lt 9 lt a gt b gt cc lt d gt Cu lt m gt lt q gt Key in SNMP SNMP SNMP SNMP Auto Auto Auto View Back Quit your community name contact location IP report to IP IP report to TCP port IP report period settings to main menu selection m 9 Types or S and then press Enter to Save Restart the system 3 8 NPort 5600 Series User s Manual Initial IP Address Configuration 10 Type y or Y and then press Enter to save the new IP address and restart NPort Ready to restart Cy Yes lt n gt No Key in your selection 3 9 4 Choosing the Proper Operation Mode In this chapter we describe the various NPort 5600 operation modes The options include an operation mode that uses a driver installed on the host computer and operation modes that rely on TCP IP socket programming concepts
39. purposes We cover Wiring Requirements Connecting NPort 5610 30 50 16 8 s Power Connecting NPort 5610 16 8 48V s Power Grounding NPort 5610 16 8 48V Connecting to the Network Connecting to a Serial Device and LED Indicators Wiring Requirements A ATTENTION Safety First Be sure to disconnect the power cord before installing and or wiring your NPort 5600 Series Wiring Caution Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Temperature Caution Please take care when handling NPort 5600 When plugged in NPort 5600 s internal components generate heat and consequently the casing may feel hot to the touch You should also pay attention to the following points e Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communication wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separately e You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares similar electrical cha
40. string is usually set to the street address where the NPort is physically located 5 7 NPort 5600 Series User s Manual Web Console Configuration IP Address Report When NPort 5600 series products are used in a dynamic IP environment users must spend more time with IP management tasks For example if NPort works as a server TCP or UDP then the host which acts as a client must know the IP address of the server If the DHCP server assigns a new IP address to NPort the host must have some way of determining NPort s new IP address NPort 5000 series products help out by periodically reporting their IP address to the IP location server in case the dynamic IP has changed The parameters shown below are used to configure the Auto IP report function There are two ways to develop an Auto IP report Server to receive NPort s Auto IP report 1 Use NPort Administrator s IP Address Report function 2 Auto IP report protocol which can automatically receive the Auto IP report on a regular basis is also available to help you develop your own software Refer to Appendix E for the Auto IP report protocol Auto report to IP Setting Factory Default Necessity E g 192 168 1 1 None Optional IP addresses of the form x x x 0 and x x x 255 are invalid Reports generated by the Auto report function will be sent automatically to this IP address Auto report to TCP port
41. 0 Series User s Manual Web Console Configuration Destination IP address 1 Setting Factory Default Necessity IP address or Domain Address None Required E g 192 168 1 1 Allows NPort to connect actively to the remote host whose address is set by this parameter Destination IP address 2 3 4 Setting Factory Default Necessity IP address or Domain Address None Optional E g 192 168 1 1 Allows NPort to connect actively to the remote host whose address is set by this parameter E ea SS Local Port 1 2 3 4 setting sd Factory Default TCP Port No 5011 Port 1 5012 Port 2 Required 5013 Port 3 5014 Port 4 Connection control Setting Factory Default Necessity Startup None Any Character None Any Character Inactivity Time DSR ON DSR OFF Startup None Required DSR ON None DCD ON DCD OFF DCD ON None The meaning of each of the above settings is given in the table below In general both the Connect condition and Disconnect condition are given 5 21 NPort 5600 Series User s Manual Web Console Configuration Connect Disconnect Description Startup None A TCP connection will be established on startup and will remain default active indefinitely A TCP connection will be established when any character is Any Character None received from the serial interface and will remain active indefinitely A TCP connection will be established when an
42. 177 254 OODOCUUDOD fia 160 127 254 fess 25500 ID Address report 1921682149 fs002 i0 seconde NPort 5600 Series User s Manual Auto IP Report Protocal And then you can develop your own programs to receive this information from the NPort Here is NPort s Auto IP Report Protocol We provide an example for you to easily develop your own programs You can find this example on Moxa s website Auto IP Report Format Moxa 4 bytes Info 0 Info 1 oF Info n Info n Field ID Length Data Length 1 1 Variable Length is Length Field ID List ID Value Description Length Note 1 Server Name Variable ASCII char 2 Hardware ID 2 Little endian 3 MAC Address 6 6 bytes MAC address If the MAC address is 00 90 E8 01 02 03 the MAC O is 0 MAC 1 is 0x90 hex MAC 2 is OxE8 hex and so on 4 Serial Number 4 DWORD Little endian 5 IP Address 4 DWORD Little endian 6 Netmask 4 DWORD Little endian 1 Default Gateway 4 DWORD Little endian 8 Firmware Version 4 DWORD JLittle endian Ver1 3 4 0x0103040 9 AP ID 4 DWORD Little endian AP ID amp Hardware ID Mapping Table AP ID Hardware ID Product 0x80005000 0x0504 NPort 5410 0x80005000 0x0534 NPort 5430 0x80005000 0x1534 NPort 54301 0x80000312 0x0312 NPort 5230 0x80000312 0x0322 NPort
43. 51 ATTENTION Before modifying NPort 5600 s configuration use Broadcast Search to locate all NPort 5600s connected to the LAN or use Specify by IP Address to locate a particular NPort 5600 Unlock Password Protection 1 If the NPort is password protected then you will not be able to use the right click method to open the configuration page A eee xl Target is password protected Please Unlock first x 6 7 NPort 5600 Series User s Manual Configuring NPort Administrator Instead select an NPort with Lock status right click the locked NPort and then select the 2 Unlock button Administrator Configuration DE ES File Function Configuration View Help F 2 gt Exit Search SearchIP Locate Configure Web Function Configuration 4 NPort s gt No Model MACAddress IP Address Status o Configuration NPort 5210 00 30 E8 0C C9 26 192 168 4 242 Monitor NPort 5210 00 90 E8 0C C8 3E 192 168 4 241 Lock i NPort 5210 00 90 8 00 08 3D 192 168 4 243 COM Mapping E es 00 90 E8 09 C2 74 BD Brondcest Search X IP Address Report Sar Ek Specify by IP Address Export Configuration Import Configuration Message Log 1 Monitor Log 0 Assign IP Address 2006 5 22 FF 08 00 25 Found NPort s 4 Now 2006 5 22 FF 08 02 35 3 After entering the correct password the Administrator will display a message box as shown here The NPort is now unlocked x G Unlock ok x
44. 6 192 168 16 130 Hi Performance FIFO Ena 9600 None 8 1 NPort 5650 16 192 168 16 130 Hi Performance FIFO Ena 9600 None Administrator COM Mapping File Function COM Mapping View Help F 2 a ey Exit Add Remove Apply Configure Function COM Mapping 16 COM Configuration Monitor 2 NPort 5650 16 19216816130 2 L Add Target Port Monitor 3 NPort 5650 16 19216816130 3 COM12 i COM Mapping 4 NPort 5650 16 192 168 16 130 4 COM13 Remove Target Ed 5 NPort 5650 16 192168 16130 5 COM14 A IPdkleas Report NPort 5650 16 192168 16130 6 COM21 cote 7 NPort 5650 16 19216816130 7 COM22 Disable 8 NPort 5850 16 19216816130 8 COM23 3 NPort 5650 16 19216816130 9 COM24 EE COM Settings 10 NPort 5850 16 192168 16 130 10 COM25 11 NPort 5650 16 192168 16 130 11 COM26 a Apply Change 12 NPort 5650 16 192168 16 130 12 COM27 Discard Change 13 NPort 5650 16 192168 16130 13 COM28 N 14 NPort 5650 16 192 168 16 130 14 COM29 Export COM Mapping 15 NPort 5650 16 192168 16 130 15 COM30 v 16 NPort 5850 16 192 168 16 130 16 COM31 Import COM Mapping fon None 8 1 None 6 25 NPort 5600 Series User s Manual Configuring NPort Administrator IP Location When NPort 5600 series products are used in a dynamic IP environment users must spend more time with IP management tasks NPort 5600 series products help out by periodically reporting their IP address to the
45. B9 RJ45 Port RJ45 Connector Female DB9 Male DB9 NPort 5610 E RS 232 NPort 5650 Ill lt Device 8 pins Cable Wiring 9 pins DSR 1 4 DTR RTS 2 gt 8 CTS GND 3 5 GND TxD 4 gt 2 RxD RxD 5 lt 3 TxD DCD 6 lt 1 DCD CTS 7 lt 7 RTS DTR 8 gt 6 DSR A 3 NPort 5600 Series User s Manual Pinouts and Cable Wiring RJ45 8 pins to Male DB9 RJ45 Port RJ45 Connector Male DB9 Female DB9 NPort 5610 RS 232 NPort 5650 En gi Device 8 pins Cable Wiring 9 pins DSR 1 6 DTR RTS 2 gt 7 CTS GND 3 5 GND TxD 4 gt 3 RxD RxD 5 lt 2 TxD DCD 6 lt 1 DCD CTS 7 lt 8 RTS DTR 8 gt 4 DSR RJ45 8 pins to Female DB25 RJ45 Port RJ45 Connector Female DB25 Male NPort 5650 Device J DB25 NPort 5610 E RS 232 o ll 8 pins Cable Wiring 25 pins DSR 1 lt 20 DTR RTS 2 gt 5 CTS GND 3 7 GND TxD 4 gt 3 RxD RxD 5 lt 2 TxD DCD 6 lt 8 DCD CTS 7 lt 4 RTS DTR 8 gt 6 DSR RJ45 8 pins to Male DB25 RJ45 Port RJ45 Connector Male DB25 Female l Y DB25 NPort 5610 ET RS 232 NPort 5650 Device 8 pins Cable Wiring 25 pins DSR 1 6 DTR RTS 2 gt 4 CTS GND 3 7 GND TxD 4 gt 2 i RxD RxD 5 3 TxD DCD 6 lt 8 DCD CTS 7
46. DTR out 6 E 4 20 DSR in 13 25 O B Well Known Port Numbers In this appendix which is included for your reference we provide a list of Well Known port numbers that may cause network problems if you set NPort 5600 to one of these ports Refer to RFC 1700 for Well Known port numbers or refer to the following introduction from the IANA The port numbers are divided into three ranges the Well Known Ports the Registered Ports and the Dynamic and or Private Ports The Well Known Ports range from 0 through 1023 The Registered Ports range from 1024 through 49151 The Dynamic and or Private Ports range from 49152 through 65535 The Well Known Ports are assigned by the IANA and on most systems can only be used by system processes or by programs executed by privileged users The following table shows famous port numbers among the well known port numbers For more details please visit the IANA website at http www iana org assignments port numbers TCP Socket Application Service 0 reserved 1 TCP Port Service Multiplexer 2 Management Utility 7 Echo 9 Discard 11 Active Users systat 13 Daytime 15 Netstat 20 FTP data port 21 FTP CONTROL port 23 Telnet 25 SMTP Simple Mail Transfer Protocol 37 Time Time Server 42 Host name server names server 43 Whois nickname 49 Login Host Protocol Login NPort 5600 Series User s Manual Well Known Port Numbers
47. IP location server in case the dynamic IP has changed e Receive NPort s IP location report e Centralize NPort s IP management in a dynamic IP environment 1 Configure NPort with Dynamic IP settings For example DHCP BOOTP and DHCP BOOTP Assign the remote Auto IP report server s IP address and UDP port Network Settings lip address 192168127254 Notmask ess 2500 Gateway fess 255255255 IP configuration C ED mes waming Saingi lows server 1 7 Y Chango Password C Loed rectors Defour OS Server 2 7 SaveMestart SAMP Rotting SIMP 6 Enable C Disable Community name pbc Contact i Location IP Addros lt roport auto report to IP frozves2140 fauto raport to UDP port faoa fauto report period a pro taconite Eile Function IP Address Report View Help F Ey gt a Exit Settings Go te Function IP Address Report Stopped Port 4002 0 No Mode MaCaddess IP Address Count_ Previous Time LastTime a Configuration Monitor Port Monitor rig COM Mapping 9 IP Address Report 3 Then configure the Local Listen Port to be the same as the NPort s Auto report to UDP port setting IP Location Settings Local UDP Listen Port 4002 J I e OK X Cancel 4 Click GO to start receiving the Auto IP address report from the NPort 6 26 NPort 5600 Series User s Manual Configuring NPort Administrator DER 4 Administrator IP Addr
48. MT If you would like to modify the real time clock select Local time NPort s firmware will modify the GMT time according to the Time Zone Time zone Setting Factory Default Necessity User selectable time zone GMT Greenwich Mean Time Optional Local time Setting Factory Default Necessity las cd GMT Greenwich Mean Time Optional 1900 1 1 2037 12 31 Click the Modify button to open the Modify time settings window to input the correct local time 101 Modify time settings Date Time eooo y ph Ah fo h feo Submit Close Time server Setting Factory Default Necessity IP or Domain address None Optional E g 192 168 1 1 or time stdtime gov tw NPort 5600 uses SNTP RFC 2030 for auto time calibration Input the correct Time server IP address or domain address Once NPort is configured with the correct Time Server address NPort will request time information from the Time server every 10 minutes 5 4 NPort 5600 Series User s Manual Web Console Configuration Console The Disable option for Web Console and Telnet Console is included for security reasons In some cases you may want to Disable one or both of these Console utilities as an extra precaution to prevent unauthorized users from accessing your NPort The factory default for both Web Console and Telnet Console is Enable Setting Factory Default Necessity
49. NPort 5600 Series User s Manual Ninth Edition June 2008 www moxa com product MOXA 2008 Moxa Inc all rights reserved Reproduction without permission is prohibited NPort 5600 Series User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice Copyright O 2008 Moxa Inc All rights reserved Reproduction without permission is prohibited Trademarks MOXA is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are periodically made to the information herein to correct such errors and these changes a
50. NPort 5600 Series User s Manual Configuring NPort Administrator 4 The previous Lock status will switch to Unlock status Administrator will keep this NPort in the Unlock status throughout this Administrator session Administrator Configuration DAR File Function Configuration View Help F 2 2 ES Exit Search SearchIP Function Configuration 4 NPort s Ez NPort Model MAC Address IP Address Status Configuration NPort 5210 00 90 E8 00 C9 26 192 168 4 242 Monitor NPort 5210 00 90 E8 00 C8 3E 192 168 4 241 Lock Port Monitor NPort 5210 00 90 E8 00 C8 3D 192 168 4 243 COM Mapping NPort 5650 16 00 90 E8 09 C2 74 192 168 16 130 Unlock X IP Address Report Message Log 2 Monitor Log 0 Description 2006 5 22 FF 08 00 25 Found NPort s 4 2006 5 22 FF 08 03 36 Unlock Ok NPort 5650 16 00 90 E8 09 C2 74 Now 2006 5 22 FF 08 03 40 The six states are as follows note that the term Fixed is borrowed from the standard fixed IP address networking terminology Lock The NPort is password protected Broadcast Search was used to locate it and the password has not yet been entered from within the current Administrator session Unlock The NPort is password protected Broadcast Search was used to locate it and the password has been entered from within the current Administrator session Henceforth during this Administrator session activating various utilities for this NPort will n
51. OMS in use Auto Enumerating COM Number for Selected Ports COMA assigned COMS Selected Ports lt y OK X Cancel Hi performance mode is the default for Tx mode If the driver completes sending data out to the NPort the driver will respond Tx Empty to the program Under classical mode the driver will not notify the user s program that Tx is completed until all Tx data has been sent out from the NPort this mode will cause lower throughput If you want to ensure that all data is sent out before further processing classical mode is recommended Enable Disable Tx Rx FIFO If disabled NPort will send one byte each time the Tx FIFO becomes empty and an Rx interrupt will be generated for each incoming byte This will result in a faster response and lower throughput If you want to use XON XOFF flow control we recommend setting FIFO to Disable 6 22 NPort 5600 Series User s Manual Configuring NPort Administrator COM Port Settings Post Number 1 Poris Selected 1st port is Port 1 _ Basic Settings Advanced Setting Serial Parameters Tx Mode Hi Pertormance FIFO Enable Ca Fast Flush only flush local buffer We have added one optional Fast Flush function to Moxa s new NPort Real COM driver NPort Administrator Suite for 2G NPort adds it after version 1 2 For some applications the user s program will use the Win32 PurgeComm function before it r
52. OutSigNumber rs232AsyncPortParity rs232PortInSpeed rs232PortOutSpeed The Input Signal Table The Output Signal Table rs232InSigTable rs2320utSigTable rs232InSigEntry rs232OutSigEntry rs232InSigPortIndex rs2320utSigPortIndex rs232InSigName rs2320utSigName rs232InSigState rs232OutSigState C 3 D Auto IP Report Protocol NPort Series provides several ways to configure Ethernet IP addresses One of them is DHCP Client When you set up the NPort to use DHCP Client to configure Ethernet IP addresses it will automatically send a DHCP request over the Ethernet to find the DHCP Server And then the DHCP Server will send an available IP address to the NPort The NPort will use this IP address for a period of time after receiving it But the NPort will send a DHCP request again to the DHCP Server Once the DHCP Server realizes that this IP address is to be released to other DHCP Client the NPort then will receive a different IP address For this reason users sometimes find that the NPort will use different IP addresses not a fixed IP address In order to know what IP address the NPort is using you need to set up parameters in Network Settings via Web browser The figure below is NPort Web console configuration window Enter the IP address and the Port number of the PC that you want to send this information to J Pan Web Console Mierosoll Internet Federer Fie A Meb Sea e o ODD Bean afwees Gury D OT OB Adress E tmr 168
53. P Address Report 16 Click the Alive column The Monitor program will sort the NPort list and put all Not Alive NPorts at the top of the list 2101 x Eile Function View Help F Exit RR Function Monitor Running 5 NPort s No Model MAC Address IPAddress live gt NPort 5230 00 90 E8 22 3 192 168 127 Not Alive NPort 5410 00 90 E8 00 0 192 168 4 105 Not Alive NPort 5430 00 90 E8 00 01 09 192 168 3 135 Alive NPort 5210 00 90 E8 00 02 50 192 168 3 119 Alive NPort 5610 8 00 90 E8 00 00 12 192 168 4 128 Alive fi Configuration Monitor Port Monitor 4 COM Mapping X IP Address Report TWN ja 17 If the NPort gets reconnected a warning will be displayed to remind the user the NPort is now Alive Alert New Monitor Event 1 Event s Stop Music Please check Monitor message window for more information 2006 5 22 FF 08 30 14 NPort 5650 16 192 168 16 130 is alive again 18 The NPort that was reconnected and is now Alive will be shown in black color Ai a File Function Monitor View Help F E Exit Add Remove A Stop Function Monitor Running 4 NPort s No Model MACAddress IP Address Configuration 1 NPort 5210 00 90 E8 00 C8 3E 192 168 4 241 Alive Monitor 2 NPort 5210 00 30 E8 00 C9 26 192 168 4 242 Alive Port Monitor 3 NPort 5210 00 90 E8 0C C8 3D 192 168 4 243 Alive 4 NPo
54. P port is the TCP port that NPort uses to listen to connections and that other devices must use to contact NPort To avoid conflicts with well known TCP ports the default is set to 4001 Command port Setting Factory Default Necessity 1 to 65535 966 Optional The Command port is a listen TCP port for IP Serial Lib commands from the host In order to prevent a TCP port conflict with other applications the user can set the Command port to another port if needed IP Serial Lib will automatically check the Command Port on NPort so that the user does not need to configure the program 5 17 NPort 5600 Series User s Manual Web Console Configuration TCP Client Mode Operating Settings Port 1 r Operation mode TCP Client Mode h O ser TCP alive check time Do 99 min qa A Inactivity time o0 0 65535 ms 0 Pp Ignore jammed IP No Yes a Data Packing P Packing length D 0 1024 Delimiter 1 0 Hex I Enable a Delimiter 2 0 Hex M Enable gf B Delimiter process Do Nothing 7 Processed only when Packing length is 0 zi Force transmit fp o 65535 ms TCP Client Mode Destination IP Address Destination IP address 1 tC f007 Destination IP address 2 D Destination IP address 3 O wo Destination IP address 4 DOO o TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional
55. RS 485 Port In some critical environments you may need to add termination resistors to prevent the reflection of serial signals When using termination resistors it is important to set the pull high low resistors correctly so that the electrical signal is not corrupted Since a particular pull high low resistor value cannot fit all environments the NPort 5650 uses DIP switches to set the pull high low resistor values for each serial port 2 5 NPort 5600 Series User s Manual Getting Started To set the pull high low resistors to 150 KQ make sure both of the assigned DIP switches are in the OFF position This is the default setting To set the pull high low resistors to 1 KQ make sure both of the assigned DIP switches are in the ON position A ATTENTION Do not use the 1 KQ setting on the NPort 5650 when using the RS 232 interface Doing so will degrade the RS 232 signals and shorten the maximum allowed communication distance NPort 5650 DIP Switches O O 2 6 S1 for Port 1 S2 for Port 2 S3 for Port 3 S4 for Port 4 S5 for Port 5 S6 for Port 6 S7 for Port 7 S8 for Port 8 S9 for Port 9 S10 for Port 10 S11 for Port 11 S12 for Port 12 S13 for Port 13 S14 for Port 14 S15 for Port 15 S16 for Port 16 3
56. S 485 gt Serial Cables for NPort 5650 2 wire RS 485 gt Pin Assignments for DB9 and DB25 Connectors NPort 5600 Series User s Manual Pinouts and Cable Wiring Port Pinout Diagrams Ethernet Port Pinouts CA Pin RS 232 1 Tx 2 Tx 3 Rx 6 Rx Serial Port Pinouts RS 232 Port Pinouts for NPort 5610 7 5 RS 232 DSR in RTS out GND TxD out RxD in DCD in CTS in WIAD MN A uN Re DTR out RS 422 485 Port Pinouts for NPort 5630 Pin RS 422 2 wire 4 wire RS 485 RS 485 1 2 ay 3 TxD 4 TxD 5 RxD Data 6 RxD Data 7 GND GND 8 2E pn RS 232 422 485 Port Pinouts for NPort 5650 RS 422 2 wire Pin RS 232 4 wire RS 485 RS 485 l I 1 DSR 2 RTS TxD 3 GND GND GND 4 TxD TxD 5 RxD RxD Data 6 DCD RxD Data 7 CTS 8 DTR NPort 5600 Series User s Manual Pinouts and Cable Wiring Cable Wiring Diagrams Ethernet Cables Straight Through Cable ME RJ45 Plug Pin 1 Cable Wiring ls N 00 N 00 ln Cross Over Cable IE RJ45 Plug Pin 1 Cable Wiring N 00 DON Serial Cables for NPort 5610 5650 RS 232 RJ45 8 pins to Female D
57. TCP IP protocol software to try to pack serial data received during the specified time into the same data frame This parameter defines the time interval during which NPort fetches the serial data from its internal buffer If data is incoming through the serial port NPort stores the data in the internal buffer NPort transmits data stored in the buffer via TCP IP but only if the internal buffer is full or if the Force transmit time interval reaches the time specified under Force transmit timeout The optimal Force transmit timeout depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and none for parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should set Force transmit timeout to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If the user wants to send the series of characters in the same packet the serial device attached to NPort should send that series of characters during a time interval less than the Force Transmit timeout for NPort and the total length of data must be less than or equal to NPort s internal buffer size The serial communication buffer size for NPort is 1 KB per port 5 20 NPort 560
58. TTY driver for Linux 2 4 x 2 6 x kernel Fixed TTY drivers for SCO Unix SCO OpenServer 5 OpenServer 6 UnixWare 7 UnixWare 2 1 SVR4 2 QNX 4 25 QNX 6 Solaris 10 FreeBSD 5 FreeBSD 6 Web Browser Telnet Console or Windows Utility 100 to 240 VAC 47 to 63 Hz or 48 VDC 20 to 72 VDC 20 to 72 VDC NPort 5610 16 8 141 mA for 100V 93 mA for 240V NPort 5610 16 8 48V 135 mA at 48V max NPort 5630 16 8 152 mA for 100V 98 mA for 240V NPort 5650 8 16 158 mA 100 VAC 102 mA 240 VAC ine 5650 S SC 8 16 164 mA 100 VAC 110 mA 240 NPort 5650 M SC 8 16 174 mA 100 VAC 113 mA 240 VAC SECC sheet metal 1 mm 190 x 44 5 x 478 mm including ears 190 x 44 5 x 440 mm without ears NPort 5600 Series User s Manual Introduction Environment Operating Temperature Storage Temperature Regulatory Approvals EMC Safety WARRANTY 0 to 55 C 32 to 131 F 5 to 95 RH 20 to 85 C 4 to 185 5 to 95 RH FCC Class A CE Class A UL CUL T V 5 years 2 Getting Started This chapter includes information about installing NPort 5600 Series The following topics are covered O Panel Layout Q Connecting the Hardware gt Wiring Requirements gt Connecting NPort 5610 30 50 16 8 s Power Connecting NPort 5610 16 8 48V s Power Grounding NPort 5610 16 8 48V Connecting to the Network Connecting to a Serial Device LED Indicators Link Indicator on the Rear Panel of NPort 5650
59. al Settings Port 01 Port alias Prca Serial Parameters Baud rate 115200 z Data bits ba Stop bits hz Parity None gt Flow control RTS cTs y FIFO C Disable Enable Interface RS 232 Only I Apply the above settings to all serial ports Submit Port alias Setting Factory Default Necessity 1 to 15 characters None Optional E g PLC No 1 Port Alias is specially designed to allow easy identification of the serial devices which are connected to NPort s serial port 5 9 NPort 5600 Series User s Manual Web Console Configuration A Serial Parameters ATTENTION Check the serial communication parameters in your Serial Device s user s manual You should set up NPort s serial parameters with the same communication parameters used by your serial devices Baudrate Setting Factory Default Necessity 50 bps to921 6 Kbps 115 2 Kbps Required Data bits Setting Factory Default Necessity 5 6 7 8 8 Required When the user sets Data bits to 5 bits the stop bits setting will automatically change to 1 5 bits Stop bits Setting Factory Default Necessity 1 1 5 2 1 Required Stop bits will be set to 1 5 when Data bits is set to 5 bits Parity Setting Factory Default Necessity None Even Odd Space Mark None Required Flow control Setting Factory Default Necessity
60. ame data frame This parameter defines the time interval during which NPort fetches the serial data from its internal buffer If data is incoming through the serial port NPort stores the data in the internal buffer NPort transmits data stored in the buffer via TCP IP but only if the internal buffer is full or if the Force transmit time interval reaches the time specified under Force transmit timeout The optimal Force transmit timeout depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and none for parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should set Force transmit timeout to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If the user wants to send the series of characters in the same packet the serial device attached to NPort should send that series of characters during a time interval less than the Force Transmit timeout for NPort and the total length of data must be less than or equal to NPort s internal buffer size The serial communication buffer size for NPort is 1 KB per port Local TCP port Setting Factory Default Necessity 1 to 65535 4001 Required The Local TC
61. ange the password Leave the password boxes blank to erase the password In this case the NPort will not have password protection ATTENTION If you forget the password the ONLY way to configure NPort is by using the Reset button on NPort s casing to Load Factory Defaults Remember to export the configuration file using Windows Administrator when you finish the configuration By using the Import function of Windows Administrator your configuration can be re loaded into NPort after resetting the parameters to their factory defaults Refer to Chapter 6 for more details about the Export and Import function 5 37 NPort 5600 Series User s Manual Web Console Configuration Load Factory Defaults Load Factory Default This function will reset all MOXA NPort Server settings to their factory default values Be aware that previous settings will be lost DODDDDDDDD Submit This function will reset all of NPort s settings to their factory default values Be aware that previous settings will be lost 5 38 6 Configuring NPort Administrator NPort Administrator and Web Console are two powerful tools that can be used to configure the settings of your NPorts Choose the method that is most convenient for you Note that this chapter uses NPort 5230 as an example to introduce the installation and configuration of NPort Administration Suite The functions and definitions are the same as for NPort 5600 The following topics are
62. ation J Main Menu Event Type f Overview O Basic Settings Cold start E Mail F Trap A Network Settings Warm start I Mail I Trap eQ Serial Settings Authentication failure F Mail I Trap a SHER IEEE i IP address changed E Mail J Accessible IP Settings Co PPP User Table Settings Password changed E Mail a By Auto Wanna SAE DCD changed i La E mail and SNMP Trap Port Mail Trap MS Event Type Port 1 F Mail I Trap C Monitor Port 2 F Mail I Trap C Change Password Port 3 I Mail I Trap C Load Factory Default port 4 T mail I Trap C Save Restart Port 5 F Mail F Trap Port 6 F Mail F Trap Port 7 F Mail I Trap Port 8 F Mail I Trap DCD changed The DCD Data Carrier Detect signal has changed also indicating that the modem connection status has changed For example a DCD change to high also means Connected between local modem and remote modem If the DCD signal changes to low it also means that the connection line is down When the DCD changes NPort 5610 will immediately send an e mail or send an SNMP trap DSR changed The DSR Data Set Ready signal has changed also indicating that the data communication equipment s power is off For example a DSR change to high also means that the DCE is powered ON If the DSR signal changes to low it also means that the DCE is powered off When the DSR changes NPort 5610 will immediately send an e mail or send an SNMP t
63. automatically on your computer when you install NPort Administration Suite 4 2 NPort 5600 Series User s Manual Choosing the proper Operation Mode A ATTENTION The important point is that Real COM Mode allows users to continue using RS 232 422 485 serial communications software that was written for pure serial communications applications The driver intercepts data sent to the host s COM port packs it into a TCP IP packet and then redirects it through the host s Ethernet card At the other end of the connection the NPort accepts the Ethernet frame unpacks the TCP IP packet and then transparently sends it to the appropriate serial device attached to one of the NPort s serial ports Real COM Mode allows several hosts to have access control over the same NPort The driver that comes with your NPort controls host access to attached serial devices by checking the host s IP address Modify the Accessible IP Setting table when the legal IP address should be required in your application TCP Server Mode In TCP Server mode NPort provides a unique TCP Server Mode IP Port address on a TCP IP network NPort waits J passively to be contacted by the host computer allowing the host computer to establish a connection with and get data from the serial device This operation mode also supports up to 4 simultaneous connections so that multiple hosts can collect data from the same serial device at the same time As illus
64. available to start the Monitor function 1 First use Broadcast Search under the Configuration Function group and then click Monitor gt Add Target gt Select target from the list 2 First click Monitor and then Add Target gt Rescan 3 Select Broadcast under the Configuration menu bar item Administrator Configuration File Function Configuration View Help F 2 2 Ey ET a Exit Search Search IP Function Configuration 4 NPort s P NPort No Model MAC Address IP Address Status o 1 NPort 5650 16 00 90 E8 09 C27A 192168 16 130 Unlock Monitor 2 NPort 5210 00 90 E8 00 C8 3E 192 168 4241 Lock Port Monitor 3 NPort 5210 00 90 E8 0C C8 3D 192 168 4 243 di COM Mapping 4 NPort 5210 00 90 E8 0C C9 26 192 168 4 242 IP Address Report 6 14 NPort 5600 Series User s Manual Configuring NPort Administrator 4 Click Monitor 5 6 Administrator Monitor File Function Monitor View Help F Exit Add Remove Go Function IP Address 92 168 4 242 Not Alive 1 Port Monitor tim COM Mapping e X IP Address Report Select Add Target Administrator Monitor File Function Monitor View Help F a gt m Exit Add Remove Go Stop Function Monitor Stopped 4 NPort s a Configuration NPort 5210 AO ma 74 0 ig L Add Target th COM 2 Remove Target A PA ced Configured COM Port SF Settings gt Go B Sp When you select add
65. ce that the bottom three options in level 2 and all of the options in level 3 have either a C or D attached The meaning is as follows e C configurable i e you are allowed to change the setting of this option e D display only i e the setting for this option is displayed but it cannot be changed This does NOT necessarily mean that the number does not change only that you cannot change it 3 3 NPort 5600 Series User s Manual Initial IP Address Configuration Level 1 Level 2 Level 3 Main Menu Server Serial number D setting Server name C Firmware ver D Model name D Network Ethernet status D setting MAC address D IP config C IP address C Netmask C Gateway C DNS server 1 C DNS server 2 C Serial set Select port C Baudrate C Data bit C Stop bit C Parity C Flow control C Tx Rx fifo C Interface C Tx Rx bytes D Line status D Op Mode set Select port C Select mode C mode Real COM TCP server TCP client UDP svr cli Alive timeout Alive timeout Alive timeout Delimiter 1 C Max connection Inact time Tnact time Delimiter 2 C Delimiter 1 Max connection Delimiter 1 Force Tx C Delimiter 2 Delimiter 1 Delimiter 2 Dest IP start 1 C Force Tx Delimiter 2 Force Tx Dest IP end 1 C Force Tx Dest IP 1 Dest port 1 C Local TCP port TCP port 1 Dest IP start 2 C Command port Dest IP 2 Dest IP end 2 C TCP port 2 Dest port 2 C Dest IP 3 Dest IP start 3 C TCP port 3 Dest IP e
66. check to make sure the NPort is connected correctly to the network and then install the driver on the host computer The second way is with Off line COM Installation without connecting the NPort to the network first Off line COM Mapping can decrease the system integrator s effort by solving different field problems Via off line installation the user can process the host software installation and then install the NPort to different fields Use the following procedure to map COM ports 1 On line COM Mapping Connect NPort to the network gt Set NPort to the proper IP address gt Map COMs to your host gt Apply Change Off line COM Mapping Map COMs to your host gt Apply Change gt Connect NPort to the network gt Configure NPort s IP address 6 20 NPort 5600 Series User s Manual Configuring NPort Administrator On line COM Mapping 1 Broadcast Search for NPorts on the network Administrator Configuration File Function Configuration View Help 2 2 y E Exit Search Search P Function Configuration 0 NPort s No Medel MAC Address IP Address Status Configuration Monitor Port Monitor 2 Broadcast Search th COM Mapping 2 Specify by IP Address 9 IP Address Report File Function COM Mapping View Help h 8 amp Ext Add Function COM Mapping 0 COM Parameter Configuration Monitor Port Monitor 0 COM Mapping 9 IP Address Report 3
67. ded into NPort by using the NPort Administrator Import function Refer to Chapter 6 for more details about using the Export and Import functions ATTENTION If your NPort application requires using password protection you must enable the cookie function in your browser If the cookie function is disabled you will not be allowed to enter the Web Console Screen Basic Settings Basic Setting Server name a NP5610 8_43 Time IDODDDDE Time zone GMT Greenwich Mean Time Dublin Edinburgh Lisbon London Local ti 2006 YA la f2 fe E le E 2 Modify Time server 19216816 Settings Web console Enable Disable Telnet console Enable Disable a LCM password protect No Yes Reset button protect E No Yes 5 3 Submit NPort 5600 Series User s Manual Web Console Configuration A ATTENTION Server name Setting Factory Default Necessity 1 to 39 characters NP model name Port No _ Serial No Optional This option is useful for specifying the location or application of different NPorts Time NPort 5600 has a built in Real Time Clock for time calibration functions Functions such as Auto warning Email or SNMP Trap can add real time information to the message First time users should select the time zone first The Console will display the real time according to the time zone compared to G
68. eads or writes data With our design after the program uses this Purge Comm function the NPort driver will keep querying NPort s firmware several times to make sure there is really no data queued in the NPort firmware buffer rather than just flushing the local buffer This kind of design is used because of some special considerations However it might take more time on the order of several hundred milliseconds than a native COM1 because it needs to work via Ethernet That s why the native COM ports on the motherboard can work fast with this function call but NPort requires much more time In order to accommodate other applications that require a faster response time the new NPort driver implements a new Fast Flush option Note that by default this function is disabled To begin with make sure there are some PurgeComm functions being used in your application program In this kind of situation you might find that your NPort exhibits a much poorer operation performance than when using the native COM1 port Once you have enabled the Fast Flush function you can check to see if there has been an improvement in performance By default the optional Fast Flush function is disabled If you would like to enable this function from the NPort Administrator double click the COM ports that are mapped to the NPort and then select the Fast Flush checkbox You should find that when Fast Flush is enabled the
69. ectory Where should NPort Administration Suite be installed Select the folder where you would like NPort Administration Suite to be installed then click Next RAEE Accessories Common Files ComPlus Applications Internet Explorer microsoft frontpage y S d test The program requires at least 1 8 MB of disk space lt Back Cancel NPort 5600 Series User s Manual Configuring NPort Administrator 3 Click Next to install the program using the default program name or select a different name a Setup NPort Administration Suite Select Start Menu Folder Where should Setup place the program s shortcuts Select the Start Menu folder in which you would like Setup to create the program s shortcuts then click Next Microsoft Office NPort Administration Suite coca 4 Click Install to proceed with the installation a Setup NPort Administration Suite Ready to Install Setup is now ready to begin installing NPort Administration Suite on your computer Click Install to continue with the installation or click Back if you want to review or change any settings Destination directory D Program Files NPortAdminSuite Start Menu folder NPort Administration Suite 5 The Installing window reports the progress of the installation 18 Setup NPort Administration Suite E loj xi Installing Please wait while Setup installs NPort Administration Suite on yo
70. er Table Settings Password Auto Warning Settings rom E mail address INP5610 8_43 NP5610 8 E mail and SNMP Trap O Event Type C Monitor E mail address 2 E mail address 1 a Sie SPSS STA E mail address 3 eT SNMP trap server lt _ Submit Mail Server Mail server Setting Factory Default Necessity IP or Domain Name None Optional User name Setting Factory Default Necessity 1 to 15 characters None Optional Password Setting Factory Default Necessity 1 to 15 characters None Optional From E mail address Setting Factory Default Necessity 1 to 63 characters None Optional E mail address 1 2 3 4 Setting Factory Default Necessity 1 to 63 characters None Optional A ATTENTION Consult your Network Administrator or ISP for the proper mail server settings Auto warning function may not work properly without proper settings NPort SMTP AUTH support LOGIN PLAIN CRAM MD5 RFC 2554 5 33 NPort 5600 Series User s Manual Web Console Configuration SNMP Trap Server SNMP trap server IP or domain name Setting Factory Default Necessity IP or Domain Name None Optional Event Type Event Type Cold start Warm start I mail T Trap Authentication failure FP mail I Trap IP address changed I Mail Password changed I Mail DCD changed Port Mail Trap Port 1 I Mail T T
71. eries b Hina pa Z Router Modem lt gt n PPP PPP Dialin Dialin Modem Internet PC Notebook 4 6 5 Web Console Configuration The Web Console is the most user friendly method available to configure NPort 5600 Series This chapter will introduce the Web Console function groups and function definitions The figures in this chapter were borrowed from the manual for NPort 5200 which uses the same Web Console user interface as NPort 5600 DOODOO Ooo Opening Your Browser Basic Settings Network Settings Serial Settings Operating Settings Real COM Mode TCP Server Mode TCP Client Mode UDP Mode Pair Connection Mode Reverse Telnet Mode Disabled Mode RFC 2217 Mode PPP Mode Accessible IP Settings PPP User Table Auto Warning Settings gt Auto warning E mail and SNMP Trap gt Event Type VVVVVV VV V Monitor gt Monitor Line gt Monitor Async gt Monitor Async Settings Change Password Load Factory Default NPort 5600 Series User s Manual Web Console Configuration Opening Your Browser 1 Open your browser with the cookie function enabled To enable your browser for cookies right click your desktop Internet Explorer icon select Properties click the Security tab and then select the three Enable options as shown in the figure below zixl Security Settings ES General Security content Connections Programs Advanced Settings Select a Web content zone to specify it
72. es products have the following features Make your serial devices Internet ready Easy to use LCM Liquid Crystal Module interface for setting up the IP address Versatile socket operation modes including TCP Server TCP Client and UDP Easy to use Windows Utility for mass installation Supports 10 100 Mbps Ethernet auto detectable Supports 16 8 port RS 232 or RS 422 485 interface or RS 232 422 485 interface Built in 15 KV ESD protection for all serial signals Supports SNMP MIB II for network management 1 2 NPort 5600 Series User s Manual Introduction Product Specifications LAN Ethernet Protection Optical Fiber Distance Min TX Output Max TX Output Sensitivity NPort 5610 Serial Interface Interface No of Ports Port Type Signals Serial Line Protection NPort 5630 Serial Interface Interface No of Ports Port Type Signals Serial Line Protection RS 485 Data Direction NPort 5650 Serial Interface Interface No of Ports Port Type Signals Serial Line Protection Power Line Protection 10 100 Mbps RJ45 Built in 1 5 KV magnetic isolation Multi mode 0 to 2 km 1310 nm 62 5 125 um 500 MHz km Single mode 0 to 40 km 1310 nm 9 125 um 3 5 PS nm km Multi mode 20 dBm Single mode 0 to 40 km 5 dBm Multi mode 14 dBm Single mode 0 to 40 km 0 dBm 36 to 32 dBm Single 34 to 30 dBm Multi RS 232 16 8 RJ45 8 pin TxD RxD RTS CTS DTR DSR DCD GND 15 KV ESD
73. es the data in the internal buffer NPort transmits data stored in the buffer via TCP IP but only if the internal buffer is full or 1f the Force transmit time interval reaches the time specified under Force transmit timeout The optimal Force transmit timeout depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and none for parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should set Force transmit timeout to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If the user wants to send the series of characters in the same packet the serial device attached to NPort should send that series of characters during a time interval less than the Force Transmit timeout for NPort and the total length of data must be less than or equal to NPort s internal buffer size The serial communication buffer size for NPort is 1 KB per port Destination IP address 1 Setting Factory Default Necessity IP address range Begin Empty Required E g Begin 192 168 1 1 End Empty End 192 168 1 10 Port 4001 Destination IP address 2 3 4 Setting Factory Default Necessity IP address range
74. ess Report File Function IP Address Report View Help FS Exit Settings Go IP Address Report Stopped Port 4002 0 No Model MAC Address IP Address Function Configuration Monitor Port Monitor rir COM Mapping Q IP Address Report 6 27 7 IP Serial LIB The following topics are covered in this chapter Q Overview O IP Serial LIB Function Groups O Example Program NPort 5600 Series User s Manual IP Serial LIB Overview What is IP Serial Library IP Serial Library is a Windows library with frequently used serial command sets and subroutines IP Serial Library is designed to reduce the complexity and poor efficiency of serial communication over TCP IP For example Telnet can only transfer data but it can t monitor or configure the serial line s parameters Why Use IP Serial Library For programmers who are familiar with serial communication IP Serial Library provides well designed function calls that have the same style as Moxa s PComm Library IP Serial Library is amazingly simple and easy to understand By including it in your VB C or Delphi programming environment you can program your own TCP IP application with the ability to control serial communication parameters NPort Serial Device Servers use 2 TCP ports for communication between the NPort and host computer s Real COM driver NPort uses a data port and command port to provide pure data transfer without decode
75. et window opens if you are prompted to input the Console password input the password and then press Enter Note that this page will only appear if the NPort is password protected Model name MAC address Serial Ho Firmvare version Please keyin your passvord NPort 5600 Series User s Manual Initial IP Address Configuration 4 Type 2 to select Network settings and then press Enter 5 Type 1 to select IP address and then press Enter 6 Use the Backspace key to erase the current IP address type in the new IP address and then press Enter lt lt Main Menu gt Network settings gt gt IP address Netmask Gateway IP configuration DNS server 1 DNS server 2 lt i gt lt 2 gt 3 gt lt 4 gt lt 5 gt lt 6 gt 7 gt lt 8 gt 93 lt a gt lt b gt lt c gt lt d gt Cu lt m gt lt q gt SNMP SNMP SNMP SNMP Auto Auto Auto View Back Quit community contact location IP report to IP IP report to TCP port IP report period settings to main menu Key in your selection 1 IP address 192 168 127 253 NPort 5600 Series User s Manual Initial IP Address Configuration 7 Press any key to continue lt lt Main Menu gt Network settings gt gt IP address Netmask Gateway IP configuration DNS server 1 DNS server 2 lt i gt lt 2 gt lt 3 lt 4 lt 5 gt lt 6 gt 2 gt lt 8 gt lt 9 lt a gt lt b gt cc
76. evice servers ensure the compatibility of network software that uses a standard network API Winsock or BSD Sockets by providing TCP Server Mode TCP Client Mode and UDP Mode And thanks to NPort s Real COM TTY drivers software that works with COM TTY ports can be set up to work over a TCP IP network in no time This excellent feature preserves your software investment and lets you enjoy the benefits of networking your serial devices instantly The NPort 5600 serial device servers support automatic IP configuration protocols DHCP BOOTP and manual configuration via NPort s handy web browser console Both methods ensure quick and effective installation and by using NPort 5600 s Windows Utility installation is very straightforward since all system parameters can be stored and then copied to other device servers simultaneously Package Checklist The Moxa NPort 5600 Series products are shipped with the following items Standard Accessories e 1 16 or 8 port serial device server e NPort Documentation amp Software CD e NPort 5600 Quick Installation Guide e Power cord Optional Accessories CBL RJ45M9 150 RJ45 8 pin to DB9 Male cable 150 cm CBL RJ45F9 150 RJ45 8 pin to DB9 Female cable 150 cm CBL RJ45M25 150 RJ45 8 pin to DB25 Male cable 150 cm CBL RJ45F25 150 RJ45 8 pin to DB25 Female cable 150 cm NOTE Notify your sales representative if any of the above items is missing or damaged Product Features The NPort 5600 Seri
77. ew gt Basic Settings t porta Network Settings Operation mode UDP Mode Y s0 Serial Settings Data Packing oS Operating Settings Packing length o 0 1024 Delimiter 1 lo Hex Enable Port 3 Delimiter 2 0 Hex Enable Port 4 Delimiter process DoNothing__ v Processed only when Packing length is 0 Port 5 a gt F RE Force transmit e 0 65535 ms Se UDP Mode Port 8 Begin End HOE Destination IP address 1 4001 Destination IP address 2 Destination IP address 3 Destination IP address 4 Local Listen port 4001 Mo 4001 4001 Apply the above settings to all serial ports Local listen port will be enumerated automatically Submit Required Factory Default Default 0 The Delimiter Process will be followed regardless of the length of the data packet If the data length in bytes matches the configured value the data will be forced out The data length can be configured for 0 to 1024 bytes Set to 0 if you do not need to limit the length Delimiter 1 Setting Factory Default Necessity 00 to FF None Optional Delimiter 2 Setting Factory Default Necessity 00 to FF None Optional Once the NPort receives both delimiters through its serial port it immediately packs all data currently in its buffer and sends it to the NPort s Ethernet port Factory Default Delimiter process Setting Necessity Do nothing Delimiter
78. he Ctrl key when selecting additional NPort 5600s or hold down the Shift key to select a group of NPort 5600s Upgrading Firmware 1 Input the password to Unlock the NPort and then right click a specific NPort and select the Upgrade Firmware function to start upgrading the firmware lt Administrator Configuration Cc 6 x File Function Configuration View Help F 2 ES Ey 2 Exit Search SearchIP Locate Configure Web Function Configuration 4 NPort s NPort No Model MAC Address IP Address Status fi Configuration 1 NPort 5210 00 90 E8 0C C9 26 192 168 4 242 Monitor 2 NPort 5210 D0 90 E8 0C C8 3E 192 168 4 241 Lock Port Monitor 3 NPort 5210 00 90 E8 0C C8 3D_ _ 192 168 4 243 fim COM Mapping NPort 5650 16 00 90 8 09 02 74 a Broadcast Search IP Address Report e amp Specify by IP Address Z Locate Z Unlock Ef Configure E Web Export Configuration lt J Import Configuration Message Log 2 Monitor Log 0 Assign IP Address q SS q q lt T g 2 Select the correct ROM file to be downloaded to the NPort Visit Moxa s website at www moxa com for the latest firmware release select Fie ee Select File File Name Browse Y Ok X Cancel 6 12 NPort 5600 Series User s Manual Configuring NPort Administrator 3 Wait patiently while the Upgrade Firmware action is being processed Sta Inn Processing please
79. he Ethernet interface Ignore jammed IP For previous versions of NPort 5200 when Max connections gt 1 and the serial device is transmitting data if any one of the connected hosts was not responding NPort 5200 would wait until the data had been transmitted successfully before transmitting the second group of data to all hosts For the current version of NPort 5200 if you select Yes for Ignore jammed IP the host that is not responding will be ignored but the data will still be transmitted to the other hosts 5 15 NPort 5600 Series User s Manual Web Console Configuration A ATTENTION Allow driver control If max connection is greater than 1 NPort will ignore driver control commands from all connected hosts However if you set Allow driver control to YES control commands will be accepted Note that since NPort 5200 may get configuration changes from multiple hosts the most recent command received will take precedence Packing length Default 0 The Delimiter Process will be followed regardless of the length of the data packet If the data length in bytes matches the configured value the data will be forced out The data length can be configured for 0 to 1024 bytes Set to 0 if you do not need to limit the length Delimiter 1 Setting Factory Default Necessity 00 to FF None Optional Delimiter 2 Setting Factory Default Necessity 00 to FF None Optional Once t
80. he NPort receives both delimiters through its serial port it immediately packs all data currently in its buffer and sends it to the NPort s Ethernet port Delimiter process Do nothing Delimiter 1 Delimiter 2 Strip Delimiter Do Nothing When Delimiter 1 or Delimiter 2 is selected the data will be transmitted when an additional byte for Delimiter 1 or an additional 2 bytes for Delimiter 2 of data is received after receiving the Delimiter When Strip Delimiter is selected when the Delimiter is received the Delimiter is deleted i e stripped and the remaining data is transmitted When Do nothing is selected the data will be transmitted when the Delimiter is received Delimiter 2 is optional If left blank then Delimiter 1 alone trips clearing of the buffer If the size of the serial data received is greater than 1 KB the NPort will automatically pack the data and send it to the Ethernet However to use the delimiter function you must at least enable Delimiter 1 If Delimiter 1 is left blank and Delimiter 2 is enabled the delimiter function will not work properly 5 16 NPort 5600 Series User s Manual Web Console Configuration Force transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional 0 Disable the force transmit timeout 1 to 65535 Forces the NPort s TCP IP protocol software to try to pack serial data received during the specified time into the s
81. he data will be forced out The data length can be configured for 0 to 1024 bytes Set to 0 if you do not need to limit the length Delimiter 1 Setting Factory Default Necessity 00 to FF hex None Optional Delimiter 2 Setting Factory Default Necessity 00 to FF hex None Optional Once the NPort 5600 receives both delimiters through its serial port it immediately packs all data currently in its buffer and sends it to the NPort 5600 s Ethernet port Delimiter 2 is optional If left blank then Delimiter 1 alone trips clearing of the buffer If the size of the serial data received is greater than 1 KB the NPort 5600 will automatically pack the data and send it to the Ethernet However to use the delimiter function you must at least enable Delimiter 1 If Delimiter 1 is left blank and Delimiter 2 is enabled the delimiter function will not work properly Delimiter process Setting Factory Default Necessity Do nothing Delimiter 1 Delimiter 2 Strip Delimiter Delimiter 1 or Delimiter 2 The data will be transmitted when an additional byte for Delimiter 1 or an additional 2 bytes for Delimiter 2 of data is received after receiving the Delimiter Do Nothing Optional Strip Delimiter When the Delimiter is received the Delimiter is deleted i e stripped and the remaining data is transmitted Do nothing The data will be transmitted when the De
82. he host computer s bus limitation such as ISA or PCI or lack of drivers for various operating systems In addition to providing socket access NPort also comes with a Real COM TTY driver that transmits all serial signals intact This means that your existing COM TTY based software can be preserved without needing to invest in additional software Three different Socket Modes are available TCP Server TCP Client and UDP Server Client The main difference between the TCP and UDP protocols is that TCP guarantees delivery of data by requiring the recipient to send an acknowledgement to the sender UDP does not require this type of verification making it possible to offer speedier delivery UDP also allows multicasting of data to groups of IP addresses Real COM Mode NPort comes equipped with COM drivers that work Real COM Mode with Windows 95 98 ME NT 2000 XP systems and also TTY drivers for Linux systems The driver COM3 IP Port establishes a transparent connection between host and serial device by mapping the IP Port of the NPort s serial port to a local COM TTY port on the host computer This operation mode also supports TCP IP up to 4 simultaneous connections so that multiple Ethernet hosts can collect data from the same serial device at the same time Driver Mode RS 232 422 485 Device A ATTENTION The driver used for Real COM Mode comes with the NPort Windows Administrator The driver 1s installed
83. ice for checking if the TCP connection is alive If there is no response NPort 5600 series will disconnect the original connection Inactivity time Setting Factory Default Necessity 0 to 65535 ms 0 Optional Idle time setting for auto disconnection 0 min means it will never disconnect Local TCP port Setting Factory Default Necessity 1 to 65535 4001 Optional Each of NPort s serial ports is mapped to a TCP port To avoid conflicts with TCP ports set port numbers to 4001 for port1 4002 for port 2 etc like the default values Map lt CR LF gt Setting Factory Default Necessity CR LF or CR LF CR LF Optional If data received through NPort 5600 s Ethernet port is sent using the enter command the data will be transmitted out the serial port with an added 1 carriage return line feed if you select the lt CR LF gt option i e the cursor will jump to the next line and return to the first character of the line 2 carriage return if you select the lt CR gt option i e the cursor will return to the first character of the line 3 line feed if you select the lt LF gt option i e the cursor will jump to the next line but not mov horizontally 5 27 NPort 5600 Series User s Manual Web Console Configuration Disabled Mode Operating Settings Port 1 Operation mode Disabled 7 T Apply the ab
84. ire El ApplyChange NPort 5650 16 192168 16 130 12 COM27 HiPe NPort 5850 16 19216816130 13 COM28 Hipo Y Pics Change NPort 5650 16 19216816130 14 COM29 HiPe amp Export COM Mapping NPort 5650 16 19216816130 15 COM30 HiPe NPort 5650 16 19216816130 16 COM31 HiPe Import COM Mapping 8 Select Discard Change to tell Administrator NOT to save the COM Mapping information to the host Administrator COM Mapping DER File Function COM Mapping View Help 2 M oS Exit Add Remove Appl Configure Function COM Mapping 16 COM NPort 5650 16 2 1 TCom2 HiPerformy None NEon SE5016 18216816130 HiPerform 22 Add Target B NPort 5650 16 192 168 16 130 HiPerfom gt lt COM Mapping NPort 585016 192168 16 130 HiPerforn a Remove Target O NPort 5650 16 192 168 16 130 Hi Pertorm Enable IP Address Report NPort 5850 16 192 168 16 130 HiPerfom NPort 5650 16 192168 16 130 Hi Perform Disable NPort 5650 16 192168 16 130 HiPetform 7 NPort 565016 192 168 16 130 HiPerform T COM Settings NPort 565016 192168 16 130 HiPerform 8 1 NPort 5650 16 192 168 16 130 Hi Perform E Anny Change 8 1 NPort 565016 192 168 16 130 Hi Perfom Discard Change HF NPort 5850 16 192168 16 130 HiPerfom n B 1 NPort 5650 16 192168 16 130 HiPerfomi 2s Export COM Mapping NPort 5650 16 192 168 16 130 Hi Perform p NPort 5650 18 192 168 16 130 HiPerfom e nport COM Mapping 9 To save the configuration to a text file select Export COM Mapping
85. limiter is received Force transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional 0 Disable the force transmit timeout 1 to 65535 Forces the NPort 5600 s TCP IP protocol software to try to pack serial data received during the specified time into the same data frame 5 29 NPort 5600 Series User s Manual Web Console Configuration This parameter defines the time interval during which NPort 5600 fetches the serial data from its internal buffer If data is incoming through the serial port NPort 5600 stores the data in the internal buffer NPort 5600 transmits data stored in the buffer via TCP IP but only if the internal buffer is full or if the Force transmit time interval reaches the time specified under Force transmit timeout The optimal Force transmit timeout depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should set Force transmit timeout to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If the user wants to send a series of characters in the same packet the serial device attached to NPort
86. llow cookies that are stored on your computer or allow per session cookies NPort 5600 series uses cookies only for password transmission NPort 5600 Series User s Manual Web Console Configuration 4 The NPort 5600 homepage will open On this page you can see a brief description of the Web Console s nine function groups Welcome to NPort s web console Model Name NPort 5610 8 Mac Address 00 90 E8 09 34 BA Serial No 43 Firmware Version a a System Uptime 0 days 00h 12m 15s NPort s web console provide the following function groups Basic Settings Server name real time clock time server IP address and Web console Telnet console Enable Disable function DODOODDDDDDOD Network Settings IP address netmask default gateway static IP or dynamic IP DNS SNMP IP location report Serial Settings Baud rate start bits data bits stop bits flow control UART FIFO Operating Settings Operation mode TCP alive check inactivity delimiters force transmit timeout ATTENTION If you can t remember the password the ONLY way to start configuring NPort is to load factory defaults by using the Reset button located near the NPort s RJ45 Ethernet port Remember to use NPort Administrator to export the configuration file when you have finished the configuration After using the Reset button to load factory defaults your configuration can be easily reloa
87. lt 5 RTS DTR 8 gt 20 DSR A 4 NPort 5600 Series User s Manual Pinouts and Cable Wiring Serial Cables for NPort 5630 RS 422 4 wire RS 485 RJ45 8 pins to Female DB9 RJ45 Port RJ45 Connector Female DB9 NPort 5630 E lt 8 pins Cable Wiring TxD 3 gt 5 TxD 4 _______ __ gt 2 RxD 5 lt 3 RxD 6 lt 1 GND E 7 7 RJ45 8 pins to Male DB9 RJ45 Port RJ45 Connector Male DB9 NPort 5630 E 8 pins Cable Wiring TxD TxD YY RxD AA RxD NOOB W GND RJ45 8 pins to Female DB25 RJ45 Port RJ45 Connector o a nN Female DB25 NPort 5630 E 8 pins Cable Wiring TxD TxD RxD VY RxD NOOB W AA GND BONWN A 5 Al WY Male DB9 RS 422 4 wire RS 485 E Device E 9 pins RxD RxD TxD TxD GND Female DB9 Device RS 422 4 wire RS 485 E 9 pins RxD RxD TxD TxD GND Male DB25 RS 422 E 4 wire RS 485 Device 25 pins RxD RxD TxD TxD GND NPort 5600 Series User s Manual Pinouts and Cable Wiring RJ45 8 pins to Male DB25 RJ45 Port RJ45 Connector Male DB25 NPort 5630 8 pins Cable Wiring TxD TxD RxD RxD GND YY NN lt lt NOOB W RJ45 8 pins to
88. n Delimiter 1 alone trips clearing of the buffer If the size of the serial data received is greater than 1 KB the NPort will automatically pack the data and send it to the Ethernet However to use the delimiter function you must at least enable Delimiter 1 If Delimiter 1 is left blank and Delimiter 2 is enabled the delimiter function will not work properly Delimiter process Do nothing Delimiter 1 Delimiter 2 Strip Delimiter Do Nothing When Delimiter 1 or Delimiter 2 is selected the data will be transmitted when an additional byte for Delimiter 1 or an additional 2 bytes for Delimiter 2 of data is received after receiving the Delimiter When Strip Delimiter is selected when the Delimiter is received the Delimiter is deleted 1 e stripped and the remaining data is transmitted When Do nothing is selected the data will be transmitted when the Delimiter is received Force transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional 0 Disable the force transmit timeout 1 to 65535 Forces the NPort s TCP IP protocol software to try to pack serial data received during the specified time into the same data frame 5 13 NPort 5600 Series User s Manual Web Console Configuration This parameter defines the time interval during which NPort fetches the serial data from its internal buffer If data is incoming through the serial port NPort stores the data in
89. name is an alphanumeric name such as moxa com that it is usually easier to remember A DNS server is a host that translates this kind of text based domain name into the numeric IP address used to establish a TCP IP connection In order to use NPort s DNS feature you need to set the IP address of the DNS server to be able to access the host with the domain name NPort provides DNS server 1 and DNS server 2 configuration items to configure the IP address of the DNS server DNS Server 2 is included for use when DNS sever is unavailable NPort plays the role of DNS client Functions that support domain name in NPort are Time Sever IP Address TCP Client Destination IP Address Mail Server SNMP Trap IP Address and IP Location Server SNMP Settings Community name Setting Factory Default Necessity 1 to 39 characters public Optional E g Support 886 89191230 300 A community name is a plain text password mechanism that is used to weakly authenticate queries to agents of managed network devices Contact Setting Factory Default Necessity 1 to 39 characters None Optional E g Support 886 89191230 300 The SNMP contact information usually includes an emergency contact name and telephone or pager number Location Setting Factory Default Necessity 1 to 39 characters None Optional E g Floor 1 office 2 Specify the location string for SNMP agents such as NPort This
90. nananononnnnanononana nano nana cnn nana B 1 Appendix C Appendix D SNMP Agent with MIB Il Auto IP Report Protocol amp RS 232 Like Group cccecssseeeeeeeseseeeeeeees 1 Introduction The Moxa NPort 5600 Series of advanced serial device servers make it easy to network enable your serial devices The NPort 5600 Series includes 8 models NPort 5610 16 NPort 5610 8 8 or 16 RS 232 ports with AC power NPort 5610 16 48V NPort 5610 8 48V 8 or 16 RS 232 ports with DC power NPort 5630 16 NPort 5630 8 8 or 16 RS 422 485 ports with AC power and NPort 5650 16 NPort 5650 8 8 or 16 RS 232 422 285 ports with AC power In this manual we often refer to the eight products collectively as 5600 or 5600 Series The following topics are covered in this chapter Overview O Package Checklist O Product Features Q Product Specifications NPort 5600 Series User s Manual Introduction Overview The NPort 5600 Series serial device servers are designed to make your industrial serial devices Internet ready instantly The compact size of the NPort 5600 device servers makes them the ideal choice for connecting your RS 232 NPort 5610 16 8 RS 422 485 NPort 5630 16 8 or RS 232 422 485 NPort 5650 16 8 serial devices such as PLCs meters and sensors to an IP based Ethernet LAN making it possible for your software to access serial devices anywhere over a local LAN or the Internet The NPort 5600 serial d
91. nd 3 C Dest IP 4 Dest port 3 C TCP port 4 Dest IP start 4 C TCP connect Dest IP end 4 C Dest port 4 C Local port C Console Web console C Telnet console C Ping C Save Restart C The part of the LCM operation that still requires some explanation is how to edit the configurable options In fact you will only encounter two types of configurable options The first type involves entering numbers such as IP addresses Netmasks etc In this case you change the number one digit at a time The up cursor A is used to decrease the highlighted digit the down cursor V is used to increase the highlighted digit and the sel button is used to move to the next digit When the last digit has been changed pressing sel simply enters the number into NPort 5600 Series memory The second type of configurable option is when there are only a small number of options from which to choose although only one option will be visible at a time Consider the 3 4 NPort 5600 Series User s Manual Initial IP Address Configuration Parity attribute under Serial set as an example Follow the tree graph to arrive at the following Parity screen The first option None is displayed with a down arrow all the way to the right This is an indication that there are other options from which to choose Press the down cursor button once to see Odd as the second option Press the down cursor button again to see Even as the third option Press the down c
92. ng Factory Default Necessity 00 to FF None Optional Once the NPort receives both delimiters through its serial port it immediately packs all data currently in its buffer and sends it to the NPort s Ethernet port 5 19 NPort 5600 Series User s Manual Web Console Configuration A ATTENTION Delimiter 2 is optional If left blank then Delimiter 1 alone trips clearing of the buffer If the size of the serial data received is greater than 1 KB the Nport will automatically pack the data and send it to the Ethernet However to use the delimiter function you must at least enable Delimiter 1 If Delimiter 1 is left blank and Delimiter 2 is enabled the delimiter function will not work properly Delimiter process Do nothing Delimiter 1 Delimiter 2 Strip Delimiter Do Nothing Required When Delimiter 1 or Delimiter 2 is selected the data will be transmitted when an additional byte for Delimiter 1 or an additional 2 bytes for Delimiter 2 of data is received after receiving the Delimiter When Strip Delimiter is selected when the Delimiter is received the Delimiter is deleted 1 e stripped and the remaining data is transmitted When Do nothing is selected the data will be transmitted when the Delimiter is received Force transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional 0 Disable the force transmit timeout 1 to 65535 Forces the NPort s
93. ntrol commands will be accepted Note that since NPort 5200 may get configuration changes from multiple hosts the most recent command received will take precedence When Max connection is set to 2 3 or 4 this means that NPort will be using a multi connection application i e 2 3 or 4 hosts are allowed access to the port at the same time When using a multi connection application NPort will use the serial communication parameters set in the console All of the hosts connected to that port must use the same serial settings If one of the hosts opens the COM port with parameters that are different from NPort s console setting data communication may not work properly 5 12 NPort 5600 Series User s Manual Web Console Configuration A ATTENTION Packing length Default 0 The Delimiter Process will be followed regardless of the length of the data packet If the data length in bytes matches the configured value the data will be forced out The data length can be configured for 0 to 1024 bytes Set to 0 if you do not need to limit the length Delimiter 1 Setting Factory Default Necessity 00 to FF None Optional Delimiter 2 Setting Factory Default Necessity 00 to FF None Optional Once the NPort receives both delimiters through its serial port it immediately packs all data currently in its buffer and sends it to the NPort s Ethernet port Delimiter 2 is optional If left blank the
94. ost on the network to initiate a connection The difference is that the RAW mode does not provide the conversion function provided by Telnet If the connected devices need to use the CR LF conversion function when controlling then users must choose Rtelnet mode Disabled Mode Setting the operation mode of a particular port to Disabled disables that port RFC2217 Mode RFC2217 is a standard driver that provides Virtual COM function RFC2217 defines general com port control options based on telnet protocol Any 3rd party driver supporting RFC2217 can be used to implement virtual COM on NPort 5600 series The driver establishes a transparent connection between host and serial device by mapping the IP Port of the NPort 5600 series serial port to a local COM port on the host computer RFC2217 Mode supports 1 connection 4 5 NPort 5600 Series User s Manual Choosing the proper Operation Mode PPP Mode NPort 5600 Device Server supports standard PPP service for out of band management if the Ethernet network crashes The PPP function enables dial in access for users who need a remote access solution When a user at a remote site uses PPP dial in to connect to NPort 5600 NPort 5600 plays the role of a dial in server After the PPP connection is established the user can remotely manage the NPort 5600 Please refer to Chapter 5 for detailed information and configuration instructions Web Server E mail Server TCP IP NPort 5600 S
95. ot require re entering the server password Blank The NPort is not password protected and Broadcast Search was used to locate it Fixed The NPort is not password protected and Search by IP address was used to locate it Lock Fixed The NPort is password protected Specify by IP address was used to locate it and the password has not yet been entered from within the current Administrator session Unlock Fixed The NPort is password protected Specify by IP address was used to locate it and the password has been entered from within the current Administrator session Henceforth during this Administrator session activating various utilities for this NPort will not require re entering the server password NPort 5600 Series User s Manual Configuring NPort Administrator Configuring NPort 5600 1 To start NPort Administrator click Start gt NPort Administration Suite gt NPort Administrator fan Accessories IE Startup ET UC Finder gt fH NPort Administration Suite E IP Serial Lib Reference an NPort Windows Driver Manager gt AA E Y E version info 2 Input the password to Unlock the NPort Right click a specific NPort and select configure to start the configuration Administrator Configuration File Function Configuration View Help FL a x Exit Search SearchIP Locate Configure Web Function Configuration 4 NPort s Status Configura
96. ove settings to all serial ports aa a a IARA aa When Operation mode is set to Disabled that particular port will be disabled Select the Apply the above settings to all serial ports option to apply this setting to the other ports RFC2217 Mode Operating Settings Port 1 Operation mode RFC 2217 Mode A TCP alive check time 0 99 min Data Packing Packing length 0 0 1024 Delimiter 1 0 Hex C Enable Delimiter 2 0 Hex C Enable Delimiter process Do Nothing v Processed only when Packing length is 0 Force transmit 9 0 65535 ms Cl Apply the above settings to all serial ports Submit TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min TCP connection is not closed due to an idle TCP connection 1 to 99 min NPort 5600 automatically closes the TCP connection if there is no TCP activity for the given time After the connection is closed NPort 5600 starts listening for another Real COM driver connection from another host 5 28 NPort 5600 Series User s Manual Web Console Configuration A ATTENTION Packing length Setting Factory Default Necessity 0 to 1024 0 Optional Default 0 The Delimiter Process will be followed regardless of the length of the data packet If the data length in bytes matches the configured value t
97. peration mode Pair Connection Slave Mode y TCP alive check time P o 99 min Local TCP port 14001 I Apply the above settings to all serial ports Submit Accessible IP Settings PPP User Table Settings C Auto Warning Settings Monitor Change Password C Load Factory Default UU Save Restart TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Required 0 min TCP connection is not closed due to an idle TCP connection 1 to 99 min NPort 5600 closes the TCP connection automatically if there is no TCP activity for the given time Local TCP port Setting Factory Default Necessity TCP port No e g 4001 4001 Required This Port No must be the same port No that you set up for the Pair Connection Master device server 5 26 NPort 5600 Series User s Manual Web Console Configuration Reverse Telnet Mode Operating Settings Port 1 Operation mode Reverse Telnet Mode X TCP alive check time 7 0 99 min Inactivity time 0 0 65535 ms Local TCP port 4001 Map lt CR LF gt CR LF y I Apply the above settings to all serial ports O Pots O Accessible IP Settings PPP User Table Settings Auto Warning Settings SC Monitor 3 Change Password C Load Factory Default Cy Save Restart TCP alive check time Setting Factory Default Necessity 0 to 99 min 0 Optional Specifies the time sl
98. r View Help F a m Exit Add Remove o Stop Function Monitor Running 3 4 NPort s No Model MAC Address IP Address Configuration 1 NPort 5650 16 00 90 E8 09 C2 74 192 168 16 130 Alive Monitor 2 NPort 5210 00 90 E8 00 C8 3E 192 168 4 241 Alive Part Monitor 3 NPort 5210 00 90 E8 0C C9 26 192 168 4 242 Alive 4 NPort 5210 00 90 E8 00 C8 3D 192 168 4 243 Alive ih COM Mapping X IP Address Report 14 When one of the NPorts loses connection with the Monitor program a warning alert will display automatically The warning music will be played at the same time Alert New Monitor Event 1 Event s Stop Musi Please check Monitor message window for more information _ Stop Musie 2006 5 22 FF 08 27 22 NPort 5650 16 192 168 16 130 is lost connection 6 18 NPort 5600 Series User s Manual Configuring NPort Administrator 15 In the Monitor screen you can see that the Not Alive NPort is marked with red color Administrator Monitor Eile Function Monitor View Help g amp JL gt E Exit Add Remove Go Stop Function Monitor Running 4 NPort s No Model MACAddress IP Address Configuration 1 NPort 5210 D0 90 E8 0C C8 3E 192 168 4 241 Alive Monitor 2 NPort 5210 D0 90 E8 0C C9 26 192 168 4 242 Alive Port Monitor 3 NPort 5210 00 90 E8 0C C8 3D 192 168 4 243 Alive MA COM Mapping 4 NPort 5650 16 00 90 E8 09 C 192 168 16 1 Not Alive X I
99. racteristics can be bundled together Keep input wiring and output wiring separate e Where necessary it is strongly advised that you label wiring to all devices in the system Connecting NPort 5610 30 50 16 8 s Power Connect NPort 5610 30 16 8 s 100 240 VAC power line with its AC connector If the power is properly supplied the Ready LED will show a solid red color until the system is ready at which time the Ready LED will change to a green color Connecting NPort 5610 16 8 48V s Power To connect NPort 5610 16 8 48V s power cord with its terminal block follow the steps given below 2 3 NPort 5600 Series User s Manual Getting Started 1 Loosen the screws on the V and V_terminals of NPort 5610 16 8 48V s terminal block eSjajeje 2 Connect the power cord s 48 VDC wire to the terminal block s V terminal and the power cord s DC Power Ground wire to the terminal V V block s V_ terminal and then tighten the terminal block screws Note NPort 5610 16 8 48V can still operate even if the DC 48V and DC Power Ground are reversed If the power is properly supplied the Ready LED will show a solid red color until the system is ready at which time the Ready LED will change to a green color You should use 8 kg cm of screw torque and 22 14 AWG of suitable electric wire to connect NOTE NPort 5610 16 8 48V s power cord to its terminal block Grounding NPort 5610 16 8 48V Gro
100. rap Mail Setting Factory Default Necessity Enable Disable Disable Optional This feature helps the administrator manage how the NPort sends e mail to pre defined e mail boxes when the enabled events such as Cold start Warm start Authentication failure etc occur To configure this feature click the Event Type Mail checkbox Trap Setting Factory Default Necessity Enable Disable Disable Optional This feature helps the administrator manage how the NPort sends SNMP Trap to a pre defined SNMP Trap server when the enabled events such as Cold start Warm start Authentication failure etc occur To configure this feature click the Event Type Trap checkbox A ATTENTION DCD changed and DSR changed event only supported by those models which have these two signals For example NPort 5210 5410 and NPort 5610 5 35 NPort 5600 Series User s Manual Web Console Configuration Monitor Monitor Line Click Line under Monitor to show the operation mode and status of each connection IPx for each of the four serial ports Monitor Line Port 1 IRFC 2217 Mode Listen 2 PPP Mode Closed 3 PPP Mode Closed 4 PPP Mode Closed 5 PPP Mode Closed 6 PPP Mode Closed Fa PPP Mode Closed 8 PPP Mode Closed Monitor Async Click Asyne under Monitor to show the current status of each of the four serial ports
101. rap Port 2 FP mail I Trap Port 3 FE Mail I Trap Port 4 I Mail I Trap Port 5 I Mail T Trap Port 6 FP mail I Trap Port 7 E Mail I Trap Port 8 FP mail T Trap Cold start This refers to starting the system from power off contrast this with warm start When performing a cold start NPort will automatically issue an Auto warning message by e mail or send an SNMP trap after booting up Warm start This refers to restarting the computer without turning the power off When performing a warm start NPort will automatically send an e mail or send an SNMP trap after rebooting Authentication failure The user inputs a wrong password from the Console or Administrator When authentication failure occurs NPort will immediately send an e mail or send an SNMP trap IP address changed The user has changed NPort s IP address When the IP address changes NPort will send an e mail with the new IP address before NPort reboots If the NPort is unable to send an e mail message to the mail server within 15 seconds NPort will reboot anyway and abort the e mail auto warning Password changed The user has changed NPort s password When the password changes NPort will send an e mail with the password change notice before NPort reboots If the NPort is unable to send an e mail message to the mail server within 15 seconds NPort will reboot anyway and abort the e mail auto warning 5 34 NPort 5600 Series User s Manual Web Console Configur
102. re incorporated into new editions of the publication Technical Support Contact Information Wwww moxa com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa China Shanghai office Toll free 800 820 5036 Tel 486 21 5258 9955 Fax 86 10 6872 3958 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 Table of Contents INTrodUcilON ira 1 1 OVA VI West ii A ii 1 2 Package Checklists niaren rea araea a E on EEA EE ASE E E EA EEEO EAEE VEETEE RES 1 2 Product Feature Scere a ee o erene estou colic Ales EE OE AE EEE EEE EEEE ERGS 1 2 Product Specificationsis iia E EE E E E E EAE 1 3 Getling Saelices 2 1 A AN 2 2 Connecting the HardWare saretan ae aloe 2 3 Wiring Requirements cia a ie a 2 3 Connecting NPort 5610 30 50 16 8 s POoWeT ooconoonccnocncccoconononcnncnncononononccnnrnnonncnnos 2 3 Connecting NPort 5610 16 8 48V s POWER oooooccoccconoconononnonnnancnncnonononononccnnonnonconno 2 3 Grounding NPort 5610 16 8 48V oe cccecsseeeceeceeeecseeecseeeeceaeeeessecaeeseenereeeeaeeees 2 4 Connecting to the NetWork cnoic mere ai netsins akea a a a s aa 2 4 Connecting to a Serial Devices sietett ororen EEEa EAE A E EREE NE ninos 2 5 LED Indicators iia dali 2 5 Link Indicator on the Rear Panel of NPort 5650 Fiber Model
103. rolls up through a list of items shown on the LCM panel s second line Vv A pee down through a list of items shown on the LCM panel s second SEL select selects the option listed on the LCM panel s second line The buttons are manipulated in a manner similar to the way a modern cellular phone operates As you move through the various functions and setting options note that the top line shows the current menu or submenu name and the bottom line shows the submenu name or menu item that is activated by pressing the SEL button Detailed Menu Options The best way to explain all of NPort s LCM functions is to refer to the table shown on the next page There are three main levels 1 2 and 3 with each level represented by a separate column The first thing to remember is that the MENU button is used to move back and forth between the LCM panel s default screen and main menu screen In addition you only need to remember to e Use the SEL button to move up one level i e left to right on the tree graph e Use the MENU button to move down one level i e right to left on the tree graph e Use the cursor keys A and V to scroll between the various options within a level i e up and down on the tree graph As you use the buttons to operate the LCM display you will notice that with very few exceptions moving up one level causes the bottom line of the display to move to the top line of the display You will also noti
104. rt 5650 16 00 90 E8 09 C2 74 19216816130 Alive tim COM Mapping X IP Address Report 6 19 NPort 5600 Series User s Manual Configuring NPort Administrator Port Monitor 1 The process described here is the same as in the previous Monitor section The only difference is that you can select more items under Port Monitor than under Monitor Administrator Port Monitor File Function Port Monitor View Help 2 x Exit Add Remove Function Go Port Monitor Stopped 22 Port s Pa NPort i Configuration Monitor i COM Mapping MAC Address IP Address Pot OP Mode Alive 92 1 Pair Conr Pair C X IP Address Report oD de e Not Alive N EARRA R 0088882 TREDI 2 Select or de select Monitor Items Use the single arrowhead buttons to move highlighted items from one box to the other Use the double arrowhead buttons to move all items from one box to the other Mentor ema Geral Settings Advanced Settings Selected mena gt Model eel MAL Addes l IP Addons Pon 4 y OP Mode kd Alve l Losd Det Y or X Carcel COM Mapping NPort Administration Suite comes with Windows 95 98 ME NT 2000 XP Real COM drivers After you install Windows Administration Suite there are two ways to set up the NPort s serial port as your host s remote COM port The first way is with On line COM Mapping On line COM Mapping will
105. ry Default Necessity Destination IP address Required Designation IP address is IP address of remote dial in server IP netmask Setting Factory Default Necessity IP netmask Optional NPort 5600 automatically assigns the netmask 255 255 255 255 We recommend leaving this space blank Modem Initial stream Setting Factory Default Necessity Modem Initial stream AT Optional Accessible IP Settings j Accessible IP Settings a o F Enable the accessible IP list Not checking Enable will allow all IPs to connect Hy No Activate the rule IP Address Netmask HO TE A am GA a tp a 3 E pr a aC A JP i El Lan 6 r COCO p lt a D lp 8 r ti i sCl 9 r CAE E 10 C Do o e 11 mj ida Eel A gt mj R al El ml a O 14 C i NPort has an IP address based filtering method to control access to itself Accessible IP Settings allows you to add or block remote host IP addresses to prevent unauthorized access Access to NPort is controlled by IP address That is if a host s IP address is in the accessible IP table then the host will be allowed to access the NPort You can allow one of the following cases by setting the parameter 5 31 NPort 5600 Series User s Manual Web Console Configuration Only one host with a specific IP address can access the NPort
106. s User s Manual Web Console Configuration A ATTENTION Inactivity time is ONLY active when TCP connect on is set to Any character Ignore jammed IP For previous versions of NPort 5200 when Max connections gt 1 and the serial device is transmitting data if any one of the connected hosts was not responding NPort 5200 would wait until the data had been transmitted successfully before transmitting the second group of data to all hosts For the current version of NPort 5200 if you select Yes for Ignore jammed IP the host that is not responding will be ignored but the data will still be transmitted to the other hosts Allow driver control Factory Default If max connection is greater than 1 NPort will ignore driver control commands from all connected hosts However if you set Allow driver control to YES control commands will be accepted Note that since NPort 5200 may get configuration changes from multiple hosts the most recent command received will take precedence Packing length Default 0 The Delimiter Process will be followed regardless of the length of the data packet If the data length in bytes matches the configured value the data will be forced out The data length can be configured for 0 to 1024 bytes Set to 0 if you do not need to limit the length Delimiter 1 Setting Factory Default Necessity 00 to FF None Optional Delimiter 2 Setti
107. s security settings Cookies a Allow cookies that are stored on your computer 9 09 O Dal Local intranet Trusted sites Restricted O Enable O Prompt g Allow per session cookies not stored sites Internet A f This zone contains all Web sites you O Disable haven t placed in other zones Enable O Prompt Security level for this zone Downloads Move the slider to set the security level For this zone B File download O Disable 5 Medium Safe browsing and still Functional Prompts before downloading potentially unsafe content Unsigned ActiveX controls will not be downloaded Appropriate for most Internet sites Custom Level O Enable AY ant demmlasd 4 Reset custom settings Reset to Medium y Reset cma 2 Type 192 168 127 254 in the Address input box use the correct IP address if different from the default and then press Enter 3 Input the password if prompted The password will be transmitted with MD5 encryption over the Ethernet Note that you will not be prompted to enter the password if the NPort is not currently password protected 3 Input Password Microsoft Internet Explorer Fie Edit View Favorites Tools Help Back gt 2 A Asearch GFavorites Ahistory Eby Address http 192 168 127 254 Input password Password uo ATTENTION If you use other web browsers remember to Enable the functions to a
108. serial ports Real COM Mode Operating Settings Port 1 Operation mode Real COM Mode TCP alive check time 7 o 99 min Max connection e Ignore jammed IP No Yes Allow driver control No Yes a Data Packing Packing length o 0 1024 Delimiter 1 O Hex Enable Delimiter 2 0 Hex Clenable Delimiter process Do Nothing xj Processed only when Packing length is 0 Force transmit o 0 65535 ms C Apply the above settings to all serial ports Submit TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional 0 min TCP connection is not closed due to an idle TCP connection 1 to 99 min NPort automatically closes TCP connection if there is no TCP activity for the given time After the connection is closed NPort starts listening for another Real COM driver connection from another host 5 11 NPort 5600 Series User s Manual Web Console Configuration A ATTENTION Max connection Setting Factory Default Necessity 1 2 3 4 1 Required Max connection is usually used when the user needs to receive data from different hosts simultaneously The factory default is 1 In this case only one specific host can access this port of the NPort and the Real COM driver on that host will have full control over the port Max connection 1 Allows only a single ho
109. ssible IPs Auto Warming IP Address Report Password Jodel Name Basi z z NPort 5230 asie Network Sei OperatingMode MAC Address Modify 00 90 E8 22 33 44 Server Mame NP5230_666 sa Number Modi Time Zone GMT Greenwich Mean Time Dublin Edinbur i Local Date 12 1 2000 Firmware Ver Ver 1 0 0 Local Time 12 01 20 AM Time Server bk Modify lt v Enable Telnet Console Click the Modify check box to modify configuration Jf OK x Cancel Configuration xj aman Accessible IPs Auto Warning IP Address Report Password Sere Basic i z NPort 5230 Network Se al OperatngMode MAC Address Mody 00 90 E8 22 33 44 erver Name NP5230_656 Serial Number Y Modify 666 Time Zone GMT Greenwich Mean Time Dublin Edinbur Local Date 5 19 2003 M Firmware Ver Ver 1 0 0 Local Time a May 2003 nl Time Server Sun Mon Tue Wed Thu 1 gt AO Tr A O Mois 11 12 13 14 15 EnablewWebl 18 E 20 21 22 5 26 7 28 2 lt v Enable Telnet Today 4 28 2003 Click the Modify check box to modify configuration Y DK X Cancel 6 11 NPort 5600 Series User s Manual Configuring NPort Administrator ATTENTION You can simultaneously modify the configurations of multiple NPort 5600s that are of the same model To select multiple NPort 5600s hold down t
110. st s Real COM driver to open the specific NPort serial port Max connection 2 to 4 Allows 2 to 4 hosts Real COM drivers to open the specific NPort serial port at the same time When multiple hosts Real COM drivers open the serial port at the same time the COM driver only provides a pure data tunnel without control ability That is this serial port parameter will use firmware s settings not depend on your application program AP Application software that is based on the COM driver will receive a driver response of success when the software uses any of the Win32 API functions The firmware will only send the data back to the driver on the host Data will be sent first in first out when data comes into the NPort from the Ethernet interface Ignore jammed IP For previous versions of NPort 5200 when Max connections gt 1 and the serial device is transmitting data if any one of the connected hosts was not responding NPort 5200 would wait until the data had been transmitted successfully before transmitting the second group of data to all hosts For the current version of NPort 5200 if you select Yes for Ignore jammed IP the host that is not responding will be ignored but the data will still be transmitted to the other hosts Allow driver control If max connection is greater than 1 NPort will ignore driver control commands from all connected hosts However if you set Allow driver control to YES co
111. target you will see an NPort list that looks the same as when using Configuration gt Broadcast Search Check the NPort you would like to Monitor and then click OK Add NPort Select From List Rescan SelectAll Clear All No Model MAC Address IPAddress NPort 5210 00 90 E8 0C C9 26 192 168 4 242 NPort 5210 00 90 E8 0C C8 3E 192 168 4 241 NPort 5210 00 90 E8 0C C8 3D 192 168 4 243 NPort 565016 00 90 E8 09 C27A 192 168 16 130 Input Manually IP Address Model NPort 5110 y OK X Cancel 6 15 NPort 5600 Series User s Manual Configuring NPort Administrator 7 The NPort list will now appear on the Monitor screen Administrator Monitor Elle Function Monitor View Help F a Exit Add Remove Go Function Monitor Stopped 4 ahi NPort 5 NPort A COM Mapping X IP Address Report 8 Administrator Monitor File Function Monitor View Help FL 2 a Exit Add Remove Go Function 0 Configuration G3 Port Monitor pr COM Mapping Y IP Address Report Remove Target Load Configured COM Port El Settings 9 Select or de select Monitor Items Use the single arrowhead buttons to move highlighted items from one box to the other Use the double arrowhead buttons to move all items in one box to the other Monitor Settings General Settings Advanced Settings De selected Items Selected Items COM Number Model i MAC Address IP Address Alive
112. ted to process user requirements is displayed in the right section The activity Log which displays messages that record the user s processing history is shown in the bottom section Administrator Configuration File Function Configuration View Help F 2 2 x Exit Search SearchIP Function Configuration 0 NPort s Ez NPort No MAC Address IP Address Status Configuration Monitor Port Monitor COM Mapping 9 IP Address Report lt Message Log 0 Monitor Log 0 Description NPort 5600 Series User s Manual Configuring NPort Administrator Broadcast Search The Broadcast Search function is used to locate all NPorts that are connected to the same LAN as your computer 1 Since the Broadcast Search function searches by MAC address and not IP address all NPorts connected to the LAN will be located regardless of whether or not they are part of the same subnet as the host Administrator Configuration File Function Configuration View Help E S 2 F 2 a Exit Search SearchIP Function Configuration O NPort s No Model MAC Address IP Address Status Configuration Monitor Port Monitor 2 Broadcast Search pea Z Specify by IP Address NE ress Hepon Message Log 0 Monitor Log 0 No Time Description Now 2006 5 22 FF 07 50 00 2 The Broadcast Search window will open and display the Model IP Address MAC Address
113. the internal buffer NPort transmits data stored in the buffer via TCP IP but only if the internal buffer is full or 1f the Force transmit time interval reaches the time specified under Force transmit timeout The optimal Force transmit timeout depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and none for parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should set Force transmit timeout to be larger than 8 3 ms so in this case it must be greater than or equal to 10 ms If the user wants to send the series of characters in the same packet the serial device attached to NPort should send that series of characters during a time interval less than the Force Transmit timeout for NPort and the total length of data must be less than or equal to NPort s internal buffer size The serial communication buffer size for NPort is 1 KB per port TCP Server Mode lOperating Settings Port 1 Operation mode TCP SeverMode y TCP alive check time 7 o 99 min Inactivity time fo o 65535 ms y Max connection pa Ignore jammed IP F No Yes Allow driver control
114. ting Settings Port 1 Operation mode Pair Connection Master Mode y TCP alive check time Fo 99 min Destination IP address 4001 F Apply the above settings to all serial ports Submit a Accessible IP Settings PPP User Table Settings 7 Auto Warning Settings C Monitor 1 Change Password O Load Factory Default O Save Restart TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Required 0 min TCP connection is not closed due to an idle TCP connection 1 to 99 min NPort 5600 closes the TCP connection automatically if there is no TCP activity for the given time 5 25 NPort 5600 Series User s Manual Web Console Configuration Destination IP address Setting Factory Default Necessity IP address or Domain Name blank Optional E g 192 168 1 1 TCP port No 4001 Required The Pair Connection Master will contact the network host that has this IP address Data will be transmitted through the port No 4001 by default Note that you must configure the same TCP port No for the device server acting as the Pair Connection Slave Pair Connection Slave Mode When using Pair Connection Mode you must select Pair Connection Slave Mode for the Operation mode of one of the NPort 5600 device servers In effect this NPort 5600 will be acting as a TCP server Operating Settings Port 1 O
115. tion 1 NPort 5210 00 90 E8 0C C9 26 192 168 4 242 Monitor 2 NPort 5210 00 90 E8 0C C8 3E 192 168 4 241 Lock Port Monitor 3 NPort 5210 00 90 E8 0C C8 3D 192 168 4 243 if COM Mapping Bronicest Search IP Address Report o p k Specify by IP Address Locate Unlock Configure Web Upgrade Firmware Export Configuration Import Configuration Message Log 2 Monitor Log 0 Assign IP Address 3 The progress bar shows that Administrator is retrieving configuration information from the specific NPort x Please wait 26 29 89 X Cancel 6 10 NPort 5600 Series User s Manual Configuring NPort Administrator 4 Refer to Chapter 5 for each parameter s function definition To modify the configuration you must first click in the modify box to activate the parameter setting box xl Information Accessible IPs Auto Warning IP Address Report Password Pot 525 Network Serial Operating Mode NPort 5230 MAC Address Modify 00 90 E8 22 33 44 ServerName NP5230_666 Serial Number C Modify 666 Time Zone GMT Greenwich Mean Time Dublin Edinbur ea Do Local Date 17 1 2000 Ver 1 0 0 Local Time 42 01 20 AM Time Server Modify y Enable web Console v Enable Telnet Console Click the Modify check box to modify configuration Y OK X Cancel x bavi Acce
116. tivity time is set to 0 the current TCP connection is kept active until a connection close request is received Although Inactivity time is disabled the NPort will check the connection status between the NPort and remote host by sending keep alive packets periodically If the remote host does not respond to the packet NPort assumes that the connection was closed down unintentionally NPort will then force the existing TCP connection to close The Inactivity time should at least be set larger than that of Force transmit timeout To prevent the unintended loss of data due to the session being disconnected it is highly recommended that this value is set large enough so that the intended data transfer is completed Max connection Setting Factory Default Necessity 1 2 3 4 1 Required Max connection is usually used when the user needs to receive data from different hosts simultaneously The factory default only allows 1 connection at a time Max connection 1 NPort only allows 1 host to open the TCP connection to the specific serial port Max connection 2 to 4 Allows 2 to 4 host s TCP connection request to open this NPort serial port at the same time When multiple hosts establish a TCP connection to the specific serial port at the same time NPort will duplicate the serial data and transmit to all of the hosts Ethernet data is sent on a first in first out basis to the serial port when data comes into NPort from t
117. trated in the figure data transmission TOE Serer proceeds as follows Se i i ORequest a 1 The host requests a connection from the NPort connection configured for TCP Server Mode OProceed with data transmission RS 232 422 485 2 Once the connection is established data can be transmitted in both directions from the host to the NPort and from the NPort to the host 4 3 NPort 5600 Series User s Manual Choosing the proper Operation Mode TCP Client Mode In TCP Client mode NPort can actively establish a TCP connection to a pre defined host computer when serial data arrives After the data has been transferred NPort can automatically disconnect from the host computer by using the TCP alive check time or Inactivity time settings Refer to chapter 5 for more details As illustrated in the figure data transmission proceeds as follows 1 The NPort configured for TCP Client Mode requests a connection from the host Once the connection is established data can be transmitted in both directions from the host to the NPort and from the NPort to the host UDP Mode Compared to TCP communication UDP is faster and more efficient In UDP mode you can multicast data from the serial device to multiple host computers and the serial device can also receive data from multiple host computers making this mode ideal for message display applications Pair Connection Mode Pair Connection Mode employs t
118. ts scenic E eO EE EE e EEE E EEE SE 6 13 MOMO inci dd Ea di ia 6 14 Port Monto ind A 6 20 COM MappME ii o ieee ites 6 20 On line COM Mapping was acini pl retar a dain aes 6 21 Off line COM Mapping venia ida 6 25 TP TG Cation OO 6 26 IP Seral CB cocos tara 7 1 O VIE Wii ie DA a A da ii ai 7 2 IP Serial LIB Function Groups sscsycscheecsecusssspedithssvesetis aa ea aeaa aE E a anioe 7 3 Example Program citrico EEEE EEEE EE piscis 7 3 Pinouts and Cable Wiring cccssseeeeeeeseeeeeeeeseneeeeeeeeeeeeeenseeneeeeneeseaees A 1 Port Pinout Diagrams oiie niner eanan i a eri eeo e i aedes i ert A 2 Ethernet Port Pinout e eener e eneee ia e eee peesi SEES EONA EE EE ENEE aE o TESE SSE A 2 Serial Port PimOuts snenie ereer aiie ris EEEE o EEEE EE R a A 2 Cable Wiring Diderams uba ti A 3 EthernetiCableS coin if A 3 Serial Cables for NPort 5610 5650 RS 232 c ccccscccsssccsseceesceeseesececseceseeeesseenees A 3 Serial Cables for NPort 5630 RS 422 4 wire RS 485 ococoooocooocccononoonnconnnconnncnnnos A 5 Serial Cables for NPort 5630 2 wire RS 485 ooooooccococooocccononoooncconononnncnnnnccnnnconoos A 6 Serial Cables for NPort 5650 RS 422 4 wire RS 485 ococoococoooccconnnoonnconnnocnnnconoss A 7 Serial Cables for NPort 5650 2 wire RS 485 ocococoocococococononononcconononnnconanononcconoss A 8 Pin Assignments for DB9 and DB25 Connectors ccconconocnoccononononcnnninnonanononnonannnonos A 9 Well Known Port Numbers cccccconoccccconnononi
119. unding and wire routing helps limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices Sepa The Shielded Ground sometimes called Protected Ground contact is the second contact from the right of the 5 pin power terminal block connector v V located on the rear panel of NPort 5610 16 48V 5610 8 48V Connect the SG wire to the Earth ground SG A ATTENTION This product is intended to be mounted to a well grounded mounting surface such as a metal panel Connecting to the Network Connect one end of the Ethernet cable to NPort 5600 s 10 100M Ethernet port and the other end of the cable to the Ethernet network There are 2 LED indicators located on the bottom left and right corners of the Ethernet connector If the cable is properly connected NPort 5600 will indicate a valid connection to the Ethernet in the following ways The bottom right corner LED indicator maintains a solid green color when the cable is properly connected to a 100 Mbps Ethernet network LAN The bottom left corner LED indicator maintains a solid orange color when the cable is properly connected to a 10 Mbps Ethernet network LAN 2 4 NPort 5600 Series User s Manual Getting Started Connecting to a Serial Device Connect the serial data cable between NPort 5600 and the serial device LED Indicators The front panels of NPort 5600 ha
120. ur NPort Factory Default IP Address NPort products are configured with the following default private IP address Default IP address 192 168 127 254 IP addresses of the form 192 168 xxx xxx are referred to as private IP addresses since it is not possible to directly access a device configured with a private IP address from a public network For example you would not be able to ping such a device from an outside Internet connection NPort applications that require sending data over a public network such as the Internet require setting up the server with a valid public IP address which can be leased from a local ISP LCM Display We recommend using the LCM display and four push buttons to configure the IP address for the first time Basic Operation If the NPort is working properly the LCM panel will display a green color The red Ready LED will also light up indicating that the NPort is receiving power After the red Ready LED turns green you will see a display similar to P 5 6 Al 0 il 6 3 8 1 2 1 6 8 i 2 Ff Z 3 4 Where e NP5610 16 is the NPort s name e 38 is the NPort s serial number e 192 168 127 254 is the NPort s IP address 3 2 NPort 5600 Series User s Manual Initial IP Address Configuration There are four push buttons on NPort s nameplate Going from left to right the buttons are Button Name Action MENU menu activates the main menu or returns to an upper level A up cursor sc
121. ur computer Creating program icons 6 3 NPort 5600 Series User s Manual Configuring NPort Administrator 6 Read through the installation notes and then click Next to proceed a Setup NPort Administration Suite Information Please read the following important information before continuing When you are ready to continue with Setup click Next NPort Administration Suite 1 Component List 1 Utilities 2 Real Com Mode Support Package 3 IP Serial Lib Package 2 Utilities Provides Configure Monitor and COM mapping administration utilities for NPort 3 Real Com Mode Support Package Provides a misc lib for Real COM management 4 IP Serial Lib Package 7 Click Finish to complete the installation of NPort Administration Suite zox Completing the NPort Administration Suite Setup Wizard Setup has finished installing NPort Administration Suite on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup 6 4 NPort 5600 Series User s Manual Configuring NPort Administrator Configuration The Administrator Configuration window is divided into four parts The top section contains the function list and online help area Windows NT does not support this chm file format The five Administrator function groups are listed in the left section A list of NPort 5600 serial device servers each of which can be selec
122. ursor button again to see Space as the fourth option Press the down cursor button yet again to see the last option Mark To choose the desired option press the SEL button when the option is showing on the screen NPort Administration Suite ARP A ATTENTION In order to use this setup method both your computer and NPort must be connected to the same NPort Administration Suite consists of some useful utility programs that are used to configure and manage your NPorts See Chapter 6 for details on how to install NPort Administration Suite and how to use this suite of useful utilities to set up IP addresses and configure your NPort You can make use of the ARP Address Resolution Protocol command to set up an IP address for your NPort The ARP command tells your computer to associate the NPort s MAC address with the intended IP address You must then use Telnet to access the NPort at which point the Device Server s IP address will be reconfigured LAN Or you may use a cross over Ethernet cable to connect the NPort directly to your computer s Ethernet card Your NPort must be configured with the factory default IP address 192 168 127 254 before executing the ARP command as described below 3 5 NPort 5600 Series User s Manual Initial IP Address Configuration Take the following steps to use ARP to configure the IP address 1 Obtain a valid IP address for your NPort from your network administrator 2
123. ve several LED indicators as described in the following table LED Name LED Color LED Function off Power is off or power error condition exists Steady on Power is on and NPort is booting up Jen Blinking Indicates an IP conflict or DHCP or BOOTP Ready server did not respond properly Steady on Power is on and NPort is functioning normally green Blinking The NPort has been located by NPort Administrator s Location function orange Serial port is receiving data 1 16 green Serial port is transmitting data off No is being transmitted or received through the serial port Link Indicator on the Rear Panel of NPort 5650 Fiber Model The rear panels of NPort 5600 have a link indicator as described in the following table LED Name LED Color LED Function off Fiber is disconnected Link green Fiber is connected and no data is being transmitted blinking Fiber is connected and data is being transmitted Real Time Clock NPort 5600 s real time clock is powered by a lithium battery We strongly recommend that you do not replace the lithium battery without the presence of Moxa s technical support engineers If you need a battery change contact Moxa for assistance A ATTENTION There is risk of explosion if the battery is replaced by an incorrect type You need to dispose used batteries according to the instructions Adjustable Pull High low Resistors for the
124. wait X Cancel Status No Model Macaddess IPAddress NPort 5230 00 90 E8 22 33 44 192 168 127 254 Waiting ATTENTION You can simultaneously upgrade the firmware of multiple NPort 5600s that are of the same model To select multiple NPort 5600s hold down the Ctrl key when selecting an additional NPort 5600 or hold down the Shift key to select a block of NPort 5600s Export Import 1 Input the password to Unlock the NPort and then right click a specific NPort and select the Export function to start Exporting the configuration file The Export Configuration function is a handy tool that can be used to produce a text file containing the current configuration of a particular NPort Administrator Configuration File Function Configuration View Help F Exit Search SearchIP Locate Configure Web Function Configuration 4 NPort s By NPort x MAC Address IP Address Status fi Configuration NPort 5210 00 90 E8 0C C9 26 192 168 4 242 ES Monitor ort 90 E8 00 C8 168 4 oc E Moni NPort 5210 00 90 E8 0C C8 3E 192 168 4241 Lock Pott Monitor 3 NPort 5210 00 90 E8 0C C8 3D 192 168 4243 fi COM Mapping 00 90 E8 09 C2 7A 192 1626 ot lich IP Address Report Broadcast Search Specify by IP Address Locate Unlock Configure Web Upgrade Firmware a Export Configuration J Import Configuration Message Log 2 Monitor Log 0 No Time Description
125. wo NPort 5600 in tandem and can be used to remove the 15 meter distance limitation imposed by the RS 232 interface One NPort 5600 is connected from its RS 232 port to the COM port of a PC or other type of computer such as hand held PDAs that have a serial port and the serial device is connected to the RS 232 port of the other NPort 5600 The two NPort 5600 units are then connected to each other with a cross over Ethernet cable both are connected to the same LAN or in a more advanced setup they communicate with each other over a WAN i e through one or more routers Pair Connection Mode transparently transfers both data and modem control signals although it cannot transmit the DCD signal between the two NPorts 4 4 TCP Client Mode E O TCP IP Ethernet Request a connection Proceed with data transmission TCP Client RS 232 422 485 Device UDP Mode y Directly proceed with data transmission a connection required TCP IP Ethernet RS 232 422 485 Device NPort 5600 Series User s Manual Choosing the proper Operation Mode Reverse Telnet Mode Unix Windows NT TCP IP NPort 5600 Series JOUlaL ee Router Server Console management is commonly used by connecting to Console AUX or COM ports of routers switches and UPS units Rtelnet works the same as RAW mode in that only one TCP port is listened to after booting up The system then waits for a h
126. y character is received from the serial interface and will be disconnected when the Inactivity time out is reached Any Character Inactivity Time A TCP connection will be established when a DSR On signal is DSR On DSR Off received and will be disconnected when a DSR Off signal is received DSR On None A TCP connection will be established when a DSR On signal is received and will remain active indefinitely A TCP connection will be established when a DCD On signal is DCD On DCD Off received and will be disconnected when a DCD Off signal is received DCD On None A TCP connection will be established when a DCD On signal is received and will remain active indefinitely A ATTENTION Up to 4 connections can be established between NPort and hosts The connection speed or throughput may be low if one of the four connections is slow since the 1 slow connection will slow down the other 3 connections A ATTENTION The Destination IP address parameter can use both IP address and Domain Name For some applications the user may need to send the data actively to the remote destination domain name 5 22 NPort 5600 Series User s Manual Web Console Configuration UDP Mode MOXA Pot 9 Port 10 Port 11 Port 12 Port 13 Port 14 Port 15 Port 16 U Accessible IP Settings DDD Hear Tahla Cattinr Y gt QI Main Menu Operating Settings C Overvi