Home
Chief KSA1022B
Contents
1. VERTICAL INSTALLATION CABLE Baap as 60 DEPTH FROM WALL Sh 1022 SHOWN V ESSORY KWG KWK MOUNTS MOUNTING SURFACE KWG AND KWK MOUNTS SOLD SEPARATELY 240 947 E E E TE 691 254 co 4 1000 06 Y i 16 00 n mia 3 9 i 450 HORIZONTAL INSTALLATION jns pt we ttt gt HOLE SIZE 508 eis S 2000 5200 SSH KSA 1022 SHOWN KWG MOUNTS V NEED KWG MOUNTS SOLD SEPARATELY FLEXIBLE REMO VEABLE CABLE MANAGEMENT COVERS Installation Instructions KSA 1022 LEGEND Tighten Fastener Apretar elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Pencil Mark Marcar con l piz Stiftmarkierung Marcar com l pis Segno a matita Potloodmerkteken Marquage au crayon Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou Phillips Screwdriver Destornillador Phill
2. Figure 22 1 Remove side cover to slide locking plate brackets B into wall track accessory A at the desired mounting location See Figure 23 NOTE Locking plate brackets must be inserted into center channel on wall track accessory 2 Reinstall side cover to wall track accessory after all locking plate brackets have been inserted See Figure 23 B wall bracket Figure 23 3 Use hex key J to install 10 button head cap screws E through 10 washers and wall plate not included into center holes of locking plate brackets B See Figure 23 4 Refer to corresponding installation manual to complete installation of specific computer hardware NOTE Wall brackets must be secured by installing screws through the top and bottom holes of the bracket See Figure 23 Cable Management NOTE Complete installation of computer hardware prior to enclosing the cable within the wall track accessory 1 Tuck cable inside cable management flap See Figure 22 Remove side cover to wall track accessory Pull cable through cable management flap until cable outlet plug extends outside the wall track accessory See Figure 22 13 KSA 1022 Installation Instructions 4 Reinstall side cover ma
3. Anchor Metal Channel SIDE VIEW Figure 12 Snap off plastic straps on anchor at wall by pushing side to side snapping off straps level with flange of plastic cap See Figure 13 Repeat steps 6 through 9 for each mounting hole Steel Stud Drywall Plastic Cap Anchor Metal Channel SIDE VIEW Figure 13 Place wall track accessory over anchors and align mounting holes in display mount with holes in anchors See Figure 3 Insert 1 4 20 x 1 3 4 Phillips pan head screws D through corresponding mounting hole on wall track accessory and into anchor C and tighten until flush against mount DO NOT overtighten See Figure 14 Repeat steps 11 through 12 for remaining 2 mounting holes KSA 1022 Installation Instructions WARNING IMPROPER INSTALLATION CAN LEAD TO EQUIPMENT FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT Overtightening of mounting hardware can damage the steel studs DO NOT overtighten mounting hardware Steel Stud Drywall Dia 3 oQ Wall Track Accessory Anchor Metal Channel SIDE VIEW Figure 14 Horizontal Installation Using Steel Studs NOTE Wall track accessory may be mounted horizontally to two studs that are 16 20 or 24 apart orto three studs that are 16 apart After determining the site meets the installa
4. Figure 2 Vertical Installation on Drywall WARNING Drywall must be at least 1 2 thick in order to install wall track accessory 1 Using wall track accessory A as a template mark location of six mounting holes on wall making sure it will be level See Figure 3 allie OR e X6 UN o D Figure 3 KSA 1022 Installation Instructions 2 Drill six 1 2 holes at locations marked in Step 1 See Figure 3 3 Hold metal channel on anchor C flat alongside plastic straps and slide channel through hole See Figure 4 Drywall Plastic Straps Figure 4 4 Holding plastic straps on anchor C pull anchor away from wall until channel rests flush behind wall making sure anchor channel is positioned vertically on stud See Figure 5 5 Slide plastic cap on anchor C towards wall until flange of cap is flush with wall See Figure 5 Drywall Plastic Cap Anchor Metal Channel SIDE VIEW Figure 5 6 Snap off plastic straps on anchor at wall by pushing side to side snapping off straps level with flange of plastic cap See Figure 6 7 Repeat steps 3 through 6 for each mounting hole Drywall Q Plastic Cap Plastic Straps Anchor Metal Channel SIDE VIEW Figure 6 8 Place walltrack accessory over anchor
5. Figure 17 9 Snap off plastic straps on anchor at wall by pushing side to side snapping off straps level with flange of plastic cap See Figure 18 10 Repeat steps 6 through 9 for each mounting hole Steel Stud Drywall Plastic Cap Plastic Straps Anchor Metal Channel SIDE VIEW Figure 18 11 Place wall track accessory over anchors and align mounting holes in display mount with holes in anchors See Figure 13 12 Insert 1 4 20 x 1 3 4 Phillips pan head screws D through corresponding mounting hole on wall track accessory and into anchor C and tighten until flush against mount DO NOT overtighten See Figure 14 13 Repeat steps 11 through 12 for remaining mounting holes WARNING IMPROPER INSTALLATION CAN LEAD TO EQUIPMENT FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT Overtightening of mounting hardware can damage the steel studs DO NOT overtighten mounting hardware Steel Stud Drywall ovo Wall Track Accessory Anchor Metal Channel SIDE VIEW Figure 19 Computer Hardware Installation on Horizontal Bracket WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the weight of each component attached to the KSA 1022 wall track accessory doe
6. See Figure 8 Install four two studs or six three studs 12 x 2 1 2 round pan wood screws F through wall accessory holes into the holes drilled in Step 4 See Figure 9 Dual studs 9 oL 4 Ge 2 EN Triple studs Q Qox Figure 9 KSA 1022 Installation Instructions Site Requirements for Steel Studs A WARNING IMPROPER INSTALLATION CAN LEAD TO EQUIPMENT FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT The figure below identifies the minimum reguirements for installation of display mounts onto a steel stud structure If the structure or its components do not meet these requirements contact the mount manufacturer for specific instructions before attempting installation It should also be noted that no other equipment should be mounted to the same stud 16 20 or 24 Studs may be used for Single or Dual Studs shown Only 16 Studs may be used for Triple Studs Must be centered on stud If back side of wall is unfinished drywall must be installed to a minimum of one stud left and right of the stud s being used to install the mount Drywall must be secured to studs with screws 12 on center N There must be a minimum of 1 7 8 48mm clearance inside wall Drywall 1 2 minimum Drywall Thickness See hazard statement on page 2 Steel Stud 2 x 4 25ga minimum a Stud type and structural strength must confo
7. and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the weight of each component attached to the KSA 1022 wall track accessory does not exceed 25 Ibs 11 3 kg or the specific weight limit for the attached mounting device Additionally there is a limit on how many components may be mounted on each bracket depending on the mounting method Refer to the table below for details Two Mount Maximum Three Mount Maximum Horizontal dual stud mounting Horizontal triple stud mounting Vertical drywall mounting Vertical single stud mounting WARNING The KSA 1022 wall track accessory CANNOT be installed horizontally on drywall without the use of wood or steel studs The drywall must have a minimum thickness of 1 2
8. INSTALLATION INSTRUCTIONS SFP WALL TRACK ACCESSORY CHIEF KSA 1022 Our Mounts Your Vision KSA 1022 Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries collectively Milestone intend to make this manual accurate and complete However Milestone makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document Chief is a registered trademark of Milestone AV Technologies All rights reserved IMPORTANT WARNINGS AND CAUTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions WARNING Failure to read thoroughly understand
9. her wall track accessory will be mounted horizontally or vertically WARNING There is a limit on how many components may be mounted on each bracket depending on the mounting method Refer to the table below for details Three Mount Maximum Two Mount Maximum Horizontal dual stud mounting Vertical drywall mounting Vertical single stud mounting WARNING The KSA 1022 wall track accessory CANNOT be installed horizontally on drywall without wood or steel studs Horizontal triple stud mounting NOTE It may be necessary to remove cable management flaps from wall track accessory in order to expose holes to be used for installation Vertical Installation using Wood Studs 1 Using stud finder or similar method locate stud 2 Align the middle mounting holes on mount with stud making sure mounting holes are centered on stud See Figure 1 Mounting holes centered on stud Figure 1 3 Using wall track accessory A as a template mark location of three mounting holes on wall See Figure 1 4 Drill three 7 64 holes See Figure 1 Install three 12 x 2 1 2 round pan wood screws through small center bracket holes and into drilled holes See Figure 2
10. ips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis pointe cruciforme Adjust Ajustar Einstellen Ajustar Regolare Afstellen Ajuster Open Ended Wrench Llave de boca Gabelschl ssel Chave de bocas Chiave a punte aperte Steeksleutel Cl fourche Remove Quitar Entfernen Remover Rimuovere Verwijderen Retirez By Hand mano Von Hand Com mao Amano Met de hand Ala main Optional Opcional Optional Opcional Opzionale Optie En option C d 3 Hex Head Wrench Llave de cabeza hexagonal e 9 9 OO CG Sechskantschl ssel Chave de cabeca sextavada Chiave esagonale Zeskantsleutel Cl t te hexagonale Security Wrench Llave de seguridad Sicherheitsschl ssel Chave de seguran a Chiave di sicurezza Veiligheidssleutel Cl de s curit KSA 1022 Installation Instructions TOOLS REQUIRED FOR INSTALLATION e Ze za 1 0 2 1 8 included 7 64 B 6 6 De AM F 6 H 6 J 1 10 1 8 Installation Instructions KSA 1022 WALL TRACK INSTALLATION 1 Determine mounting location on wall 2 Determine whet
11. king sure the cable runs through the cable hole See Figure 22 cable management flap typical Figure 24 14 Installation Instructions KSA 1022 15 KSA 1022 Installation Instructions CHIEF Our Mounts Your Vision Chief Manufacturing a division of Milestone AV Technologies 8834 00004 2008 Milestone AV Technologies www chiefmfg com 10 08 USA International Europe Asia Pacific A P F A P F A 570 8401 Eagle Creek Parkway Savage MN 55378 800 582 6480 952 894 6280 877 894 6918 952 894 6918 Fellenoord 130 5611 ZB EINDHOVEN The Netherlands 31 0 40 2668620 31 0 40 2668615 Room 24F Block D Lily YinDu International Building LuoGang BuJi Town Shenzhen CHINA 3l rb p zs Sp ESI oS DER 24F 86 755 8996 9226 486 755 8996 9217
12. rm to the North American Specification for the Design of Cold Formed Steel Structural Members 362 S 125 18 C Shaped S Stud Section Installation Instructions KSA 1022 Vertical Installation using Steel Studs After determining the site meets the installation requirements 1 Identify desired mounting location on wall 2 Using a stud finder or similar method locate stud 3 Align the middle mounting holes on mount with stud making sure mounting holes are centered on stud See Figure 10 4 Using wall track accessory as a template mark location of three mounting holes on wall See Figure 10 A Sai 1 Mounting holes centered on stud 0 X T d Figure 10 5 Drill three 1 2 holes in locations marked in Step 4 6 Hold metal channel on anchor C flat alongside plastic 7 straps and slide channel through hole See Figure 11 Drywall Plastic Sae N Figure 11 Holding plastic straps anchor C pull anchor away from wall until channel rests flush behind wall making sure Plastic Cap 10 11 12 13 Plastic Straps anchor channel is positioned vertically on stud See Figure 12 Slide plastic cap on anchor C towards wall until flange of cap is flush with wall See Figure 12 Steel Stud Drywall gg
13. s and wall plate not included into center holes of locking plate brackets B See Figure 21 Refer to corresponding installation manual to complete installation of specific computer hardware 12 Figure 21 Installation Instructions KSA 1022 Computer Hardware Installation on Vertical Bracket WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the weight of each component attached to the KSA 1022 wall track accessory does not exceed 25 Ibs 11 3 kg or the specific weight limit for the attached mounting device Additionally there is a limit on how many components may be mounted on each bracket depending on the mounting method Refer to the table below for details Two Mount Maximum Three Mount Maximum Horizontal dual stud mounting Horizontal triple stud mounting Vertical drywall mounting Vertical single stud mounting WARNING For vertical mounting on wood or steel studs a minimum distance of 8 must exist between mounted devices For vertical mounting on drywall a minimum distance of 16 must exist between mounted devices See Figure 22 Wood or Steel Studs Drywall 0 D 0 i minimum H 16 T min 0 9 WI 0 0 0 D 0 0
14. s and align mounting holes in display mount with holes in anchors See Figure 6 9 Insert 1 4 20 x 1 3 4 Phillips pan head screws D through corresponding mounting hole on wall track accessory and into anchor C and tighten until flush against mount DO NOT overtighten See Figure 7 10 Repeat steps 8 through 9 for remaining 5 mounting holes Drywall D x 6 o Wall Track Accessory Anchor Metal Channel SIDE VIEW Figure 7 Installation Instructions KSA 1022 Horizontal Installation using Wood Studs NOTE Wall track accessory may be mounted horizontally to two studs that are 16 20 or 24 apart orto three studs that are 16 apart 1 Use a stud finder or similar method to determine location of studs 2 Drawavertical line down the center of the studs to be used See Figure 8 3 Remove cable management flaps from wall track accessory to expose holes to be used for installation 4 Using wall track accessory as a template mark location of three mounting holes on wall Make sure wall track accessory is level See Figure 8 WARNING Only long holes may be used to mount device on dual studs DO NOT mount device using the small holes unless mounting on three studs RS Triple Studs Figure 8 5 Drill 7 64 holes at each marked location
15. s not exceed 25 Ibs 11 3 kg or the specific weight limit for the attached mounting device Additionally there is a limit on how many components may be mounted on each bracket depending on the mounting method Refer to the table below for details Two Mount Maximum Three Mount Maximum Horizontal dual stud mounting Horizontal triple stud mounting Vertical drywall mounting Vertical single stud mounting WARNING For horizontal dual stud mounting on wood or steel studs a minimum distance of 8 must exist between mounted devices For horizontal triple stud mounting on wood or steel studs a minimum distance of 14 must exist between mounted devices See Figure 20 11 KSA 1022 Installation Instructions 1 8 minimum a 0000 0 Dual Stud Mounting 14 minimum EN ES 090 0 029209000 Triple Stud Mounting Figure 20 wall bracket Remove side cover to slide locking plate brackets B into wall track accessory A at the desired mounting location See Figure 21 NOTE Locking plate brackets must be inserted into the top channel and second channel from the bottom Reinstall side cover to wall track accessory after all locking plate brackets have been inserted See Figure 21 Use hex key J to install 10 button head cap screws E through 10 washer
16. tion requirements 1 Identify desired mounting location on wall 2 Use a stud finder or similar method to determine location of studs 3 Draw a vertical line down the center of the studs to be used See Figure 8 4 Using wall track accessory A as a template mark location of three mounting holes on wall Make sure wall track accessory is level See Figure 8 WARNING Only long holes may be used to mount device on dual studs DO NOT mount device using the small holes unless mounting on three studs 5 Drill 1 2 holes at each marked location See Figure 8 10 ee Dual Studs Triple Studs Figure 15 6 Hold metal channel on anchor D flat alongside plastic straps and slide channel through hole See Figure 16 Drywall Plastic Straps Figure 16 7 Holding plastic straps on anchor C pull anchor away from wall until channel rests flush behind wall making sure anchor channel is positioned vertically on stud See Figure 17 8 Slide plastic cap on anchor C towards wall until flange of cap is flush with wall See Figure 17 Installation Instructions KSA 1022 Steel Stud Drywall Plastic Cap Anchor Metal Channel SIDE VIEW