Home

Omnitron iConverter 10/100

image

Contents

1. Note Attaching an auto negotiating UTP port toa non auto negotiating manual forced hard coded UTP port may result in an unpredictable port setting with excessive collisions and poor link performance When operating in Manual mode both mating ports MUST be set manually to the same speed and duplex mode RJ45 Crossover Push Button Switch not shown When connecting the UTP to a hub or switch set switch to Straight Through factory setting When connecting to a workstation set to Crossover Page 8 BOARD MOUNTED DIP SWITCHES 4 _ BE RFD Remote Fault Detect Enable 3 C BPOEN Backplane Enable 2 E LP Link Propagate Link Segment 1 FLOWEN Flow Control Enable PAUSE lt Down Fig 4 Board Mounted DIP Switches LINK MODES SW4 and SW1 The module supports multiple link modes for fault detection and isolation Link Segment should be used for the initial installation of the module Once installed and operational the link mode can be modified Link modes are controlled by DIP switch 2 and 4 BPOEN A and B Backplane Enable DIP Switch When the A and B Backplane Enable BPOEN DIP switch is in the UP position both the A and B backplane ports are enabled and connect to the backplane to facilitate In Band management When the BPOEN switch is in the DOWN position factory setting both ports are disabled and disconnected from the backplane Page 9 SPECIFICAT
2. On Full Duplex detected Blinking Collision in HDx mode UTP Link Green On Link Rapid Blinking activity 0 5Hz blinking SFD error detected Page 11 Warning The operating description in this Instruction Manual is for use by qualified personnel only To avoid electrical shock do not perform any servicing of this unit other than that contained in the operating instructions unless you are qualified and certified to do so by Omnitron Systems Technology Inc Warranty This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment TO REGISTER COMPLETE AND MAIL OR FAX THE ENCLOSED REGISTRATION FORM Or you may register your product on the Internet at www omnitron systems com During the warranty period Omnitron will at its option repair or replace a product which is proven to be defective For warranty service the product must be sentto an Omnitron designated facility at Buyer s expense Omnitron will pay the shipping charge to return the product to Buyer s designated US address using Omnitron s standard shipping method Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate use and or maintenance of the equipment by Buyer Buyer supplied e
3. 0Mbps fiber port and two 10 100 Ethernet backplane ports A and B that can connect to adjacent modules within the same chassis When the 10 100 A and B ports are enabled using the BPOEN DIP Switch they connect via the chassis backplane to the slots on the left and right sides of the 10 100 module When another switch based module with backplane port connections such as a second 10 100 or an NMM is installed in an adjacent slot it can be connected via the backplane to the 10 100 to facilitate a multi module configuration Chassis A Lin Backplane Arink Internal Internal 10 100 10 100 select g switch chip switch chip NMM UTP Fiber UTP 4 port 10 100 UTP 10 port 100 port 10 100 port Switch NMM Module 10 100 Module 4Tx Module Fig 1 10 100 Application Example Page 3 DIP SWITCH SETTINGS Front Panel DIP switch Settings Fiber Full Duplex FDX __ HDX Fiber Half Duplex UTP Auto Negotiate AN Man UTP Manual UTP 100Mbps 100 EE 10 UTP 10Mbps UTP Full Duplex FDX _ HDX UTP Half Duplex Fig 3 Front Panel Dip Switches Fiber Full Half Duplex FDX HDX DIP switch When in the Fiber Full Half Duplex DIP switch is in the Fiber Full Duplex FDX position factory setting the fiber port operates in Full Duplex mode When in the Fiber Half Duplex HDX position the fiber port operates in Half Duplex
4. IONS Model Type 10 100 Protocols 100BASE FX 10BASE T or 100BASE TX UTP Fiber SC ST LC MT RJ Connectors Single Fiber SC UTP X over LS LP RFD SFD Auto Man 10 100 FDX HDX Flow Control Controls Power F O FDX HDX FO link activity Auto FDX HDX 10 100 UTP link activity LED Displays Page 13 FLOWEN Flow Control PAUSE DIP switch When the Flow Control FLOWEN DIP switch is in the UP position flow control functionality is enabled When the module is configured for FDX PAUSE functionality is enabled When the module is configured for HDX jam functionality is enabled When flow control is enabled a port will generate either a pause or jam frame when internal resources are not available to receive the next incoming frame When the DIP switch is in the DOWN position factory default flow control is disabled Page 10 SPECIFICATIONS W 0 850 x D 4 5 x H 2 8 UL CE FCC Class A Power i 0 95A 3 3VDC typical C Standard 0 to 50 Temperature Wide 40 to 60 C Storage 40 to 80 C 5 to 95 non condensing MTBF hrs 1 050 000 Page 14 LED INDICATORS LED COLOR DESCRIPTION Power Yellow On Power Fiber FDx Green On Full Duplex selected F O Link Green On Link Rapid Blinking activity 0 5Hz blinking SFD error detected UTP Auto Green On Auto Negotiation enabled UTP 100 Green On 100 Mbps link UTP 10 Green On 10 Mbps link UTP FDx Green
5. P port transmits a Link signal only when receiving a Link at the fiber port The fiber port transmits a Link signal only when receiving a Link signal at both the fiber port and the UTP port As a result fiber faults no Link received at the fiber are looped back and can be reported to the network core In addition connecting two back to back converters which are both set to SFD facilitates dual loop back where fiber faults are reported to both ends of the network A blinking fiber link LED on a converter indicates a fault of the transmit fiber or UTP cables of that converter Fig 3 e NOTE Connecting two converters with both set to RFD mode is not supported and will cause a lockup NOTE Converters in SFD mode must be deployed in pairs Page 5 ABOUT THIS MANUAL This document supports revision xx 19 or later of the 10 100 This revision incorporates the following features 1 Product support Flow Control via the on board DIP switch selections 2 Symmetrical Fault Detection has been added to the module OVERVIEW The iConverter 10 100 converters support the IEEE 802 3 Ethernet standard and convert between Ethernet 10BASE T or 100BASE TX unshielded twisted pair UTP and Fast Ethernet fiber 100BASE FX Models are available for multimode MM and single mode SM dual fiber and single mode single fiber The 10 100 supports Half Duplex and Full Duplex modes and features a crossover UTP switch for easy attachment to hu
6. bs switches and workstations The 10 100 can be used as a standard two port UTP to fiber converter It can also use its two additional 10 100 backplane ports to connect to adjacent modules and accommodate flexible network configurations like In Band management and multi module configurations The iConverter 19 Module 5 Module or 2 Module Chassis have backplanes that facilitate connectivity between adjacent modules The 10 100 can be used in an unmanaged or managed fashion When unmanaged it can be installed in a chassis without an iConverter Network Management Module NMM or iConverter 10 100M To be managed an NMM module Page 2 LS LS ro Fiber gt gt a UTP UTP Oj OM Ole Switch 1 Converter A Converter B Switch 2 LS LS gt PX gt b j4 O j4 Switch 1 Converter A Converter B Switch 2 LP LP gt O gt X gt c O je Oje oje Switch 1 Converter A Converter B Switch 2 LP RFD LP gt O PY PA d Xj WI Oo Switch 1 Converter A ConverterB Switch 2 SFD SFD gt O X gt ot x e Wt OO KOM Switch 1 Converter A Converter B Switch 2 LEDLit 4 LED Blinking JX LED Off O LED Status depends on connected device Fig 2 10 100 Link Modes Page 6 or 10 100M module must be installed in the same chassis PORT STRUCTURE Using a 4 port switch design the 10 100 features a front plane 10 100 UTP port a front plane 10
7. mode and its distance is limited by the IEEE 802 3 standard to 412 meters UTP Auto Manual Negotiate AN MAN DIP switch When the UTP Auto Manual Negotiate DIP switch is in the UTP Auto Negotiate AN position factory setting the converter auto negotiates and matches the 10 100 speed and duplex mode of a mating auto negotiating device connected to its UTP port When the UTP Auto Manual Negotiate DIP switch is in the UTP Manual Man position the converter does not auto negotiate and operates in the mode selected by the Full Half Duplex FDX HDX and 10 100 DIP switches UTP 10 100 DIP switch When the UTP Auto Manual Negotiate DIP switch is in the UTP Manual Man position the UTP 10 100 Page 7 Fig 1 depicts a chassis with three modules plugged into three of its adjacent backplane slots The adjacent slots are connected via the backplane using the A and B 10 100 links In this example the 10 100 in the center slot connects to the slot on its left using the A link and to the slot on its right using the B link In this example the module on the left is a Network Management Module NMM and it connects via its A backplane port to the 10 100 facilitating In Band management via the fiber uplink The module on the right is a 4 port 10 100 switch module 4Tx and it connects via its B backplane port to the 10 100 facilitating a 5 port 10 100 Ethernet switch with a fiber u
8. osr Omnitron Systems Technology Inc iConverter 10 100 User Manual Connector Type Fiber Type Distance LC MM 5km 8380 0 8382 0 8384 0 8386 0 SM 30km 8381 1 8383 1 8385 1 8387 1 SM 60km 8381 2 8383 2 8387 2 SM 120 km 8383 3 8387 3 iConverter 10 100 Single Fiber Modules E aa iloisin Tx 1310nm Tx 1550 nm onnector Distance Rx 1550 nm Rx 1310 nm Type SM SC 20 km 8390 1 8391 1 SM SC 40 km 8390 2 8391 2 SM SC 60 km 8390 3 8391 3 For wide temperature 40 to 60 C add a W to the end of the model number Consult factory for extended temperature 40 to 75 C models When using single fiber SF media converter models the Tx wavelength on one end has to match the Rx wavelength on the other In Link Propagate LP a port transmits a Link signal only when receiving a Link at its other port For example the UTP transmits a Link only when receiving a Link at the fiber port Fig 2 c In Remote Fault Detection Link Propagate RFD LP the UTP port transmits a Link signal only when receiving a Link at the fiber port The fiber port transmits a Link signal only when receiving Link signals at both the fiber port and the UTP port As a result fiber faults no Link received at the fiber are propagated forward and looped back for fault reporting at both the network core and the customer location Fig 2 d In Symmetrical Fault Detection SFD the UT
9. plink configuration This 3 module configuration provides an effective 5 port 10 100 managed switch with a fiber uplink configuration This example shows how the 10 100 can be used either as a traditional managed or unmanaged media converter or to create flexible and effective network switch configurations For more information about individual chassis A and B backplane links please refer to the specific chassis user manual LINK MODES In order to accommodate different user needs the 10 100 supports four different linking modes see Fig 2 In Link Segment LS a port transmits a Link signal independently of any received Link at any other port For example the UTP transmits a Link regardless of the fiber receiving a Link Fig 2 a amp b Page 4 DIP switch selects the speed of the UTP port When in the 100 position factory setting the UTP port operates at 100 Mbps When in the 10 position the UTP port operates at 10 Mbps UTP Full Half Duplex FDX HDX DIP switch When the UTP Auto Manual Negotiate DIP switch is in the UTP Manual Man position the UTP Full Half Duplex FDX HDX DIP switch selects the duplex mode of the UTP port When in the Full Duplex FDX position factory setting the UTP port operates in Full Duplex mode When in the Half Duplex HDX position the UTP port operates in Half Duplex Set the duplex mode to match the connecting device and check for link status
10. quipment Buyer supplied interfacing unauthorized modifications or tampering with equipment including removal of equipment cover by personnel not specifically authorized and certified by Omnitron or misuse or operating outside the environmental specification of the product including but not limited to voltage ambient temperature radiation unusual dust etc orimproper site preparation or maintenance No other warranty is expressed or implied Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose Page 15 MOUNTING AND CABLE ATTACHMENT iConverter modules are hot swappable and can be installed into any chassis in the iConverter family 1 Carefully slide the iConverter module into the installation slot aligning the module with the installation guides NOTE Ensure that the module is firmly seated against the backplane 2 Secure the module by securing the panel fastener screw attached to module to the chassis front 3 Attach the UTP port via a category 5 cable to a 100BASE TX or 10BASE T Ethernet device 4 Attach the fiber port via an appropriate multimode or single mode fiber cable to a 100BASE FX Ethernet device The iConverter transmit Tx must attach to the receive side on other device the receive Rx must attach to the transmit 5 When using single fiber SF media converter models the Tx wavelength on one end has to match the Rx wavelength on the o
11. ther Note that based on this guideline the SF media converter models must be used in pairs such as the 8390 1 matched with the 8391 1 Page 12 Exclusive Remedies The remedies provided herein are the Buyer s sole and exclusive remedies Omnitron shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any legal theory TECHNICAL SUPPORT For help with this product contact our Technical Support Phone 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 140 Technology Dr 500 Irvine CA 92618 USA E mail support omnitron systems com URL www omnitron systems com Form 040 08380 001M 6 11 Page 16