Home

Omnitron iConverter 10/100M2

image

Contents

1. COMMAND LINE INTERFACE To access the Command Line Interface CLI connect the 10 100M2 RS 232 Console Port to the COM port of a computer equipped with terminal emulation software such as HyperTerminal The Console Port DCE is a mini DIN 6 female connector which can be changed to a DB 9 connector with the included adapter The 10 100M2 Console Port is a standard asynchronous serial interface Start HyperTerminal and select the correct COM Port in the HyperTerminal Connect To window Set the serial port to the following Bits Per Second 57 600 Stop Bits 1 Data Bits 8 Parity NONE Hardware Flow Control NONE Once connected press lt ENTER gt to bring up a command line prompt on the attached PC Anew 10 100M2 module does not have a password and will skip the Password Entry screen and go straight to the Management Options screen If a password has been set the Password Entry screen will be displayed Type the password and press lt ENTERs the 10 100M2 will respond with the Management Options screen
2. Management Options iConverter Serial Agent Network Management 1 Chassis and Module Management 2 Set Module Name Preferences Management Module Preferences IP and Control Preferences SNMP Preferences Abandon Preference Changes Save Preference Changes Restore Factory Defaults Restart Management Module Other Networking Features Management Module Maintenance 10 Firmware Update 11 Set Date Time IP Address 192 168 1 220 Chassis Number 1 Enter Choice lt H gt elp E lt x gt it gt Figure C Command Line Interface Menu Options The CLI interface allows for the detailed configuration of the module It is recommended to configure the module with an IP address associated with the attached network Also SNMP traphost address should be configured if the module is managed with an SNMP based Management System See the 10 100M2 User Manual for complete information 4 VERIFY OPERATION Once the module has been installed and configured per steps 1 3 verify the module is operational by viewing the LED indicators The Power LED indicates the NEMO Siete aor 100Mbps ae ee module is receiving power Fiber Optics Green No Fiber Link on Fiber link is active a a EQ inking Fiber Data Activity The Fiber Optic link LED indicates the fiber optic connection has been established Verify the Link Mode On Blinking State 40Mbps not On 10Mbps mode selected Green ave and the UTP link is active Blinking UTP D
3. andwidth Control rate limiting capabilities The 10 100M2 can be managed using Omnitron s NetOutlook SNMP Management Software 3rd Party SNMP Client Telnet or the Command Line Interface CLI For more information including the complete User Manual on the 10 100M2 module access Omnitron s documentation download web page to view all relevant documents http www omnitron systems com downloads php INSTALLATION PROCEDURE 1 Configure DIP Switches 2 Install Standalone Module and Connect Cables 3 Configure Module via Command Line Interface 4 Verify Operation 1 CONFIGURE DIP SWITCHES DIP SWITCH BANK 1 SW1 UTP FIBER PAUSE ENABLE When a port is operating in Up Auto Negotiation AN its Pause operation mode is oss oo determined by the Pause sw Bank 1 capability advertised during AN between itself and the link partner The port advertises its Pause capability Symmetrical or No Pause during AN based on the Pause Disable Enable DIP switch setting When a port is operating in Manual mode its Pause operation mode is based on the Pause Disable Enable DIP switch setting SW2 FIBER FULL HALF DUPLEX Setting this DIP switch to Half Duplex HDX facilitates a connection that supports Down Figure A DIP Switch Location Half Duplex Setting this DIP switch to Full Duplex FDX facilitates a connection that supports Full Duplex operation SW3 UTP AUTO MANUAL When
4. ata Activity selection is set to Link Segment UTP port 100Mbps not O 100Mbps mode selected LS Until a stable link is 00 Mbps Green active and UTP link is active 100 Blinking UTP Data Activity established leave the Link Mode configured for LS After a Link presence is established the Link Mode selection can be modified The UTP link LED indicates the module has established a connection across its UTP port UTP port Half Duplex PEN Full Duplex Green when UTP link One FUN DUPIE Xana UTP link EDX eee is active FDX is active Review Link Modes section for other LED display patterns Figure D LED Indicators Form 040 8900N 001 B Omnitron Systems Technology 140 Technology Dr 500 Irvine CA 92618 949 250 6510 tel 949 250 6514 fax www omnitron systems com osr Omnitron Systems Technology Inc iConverter 10 100M2 Standalone Module QUICK START GUIDE The Omnitron iConverter 10 100M2 is a carrier class Network Interface Device NID that provides 10BASE T or 100BASE TX 10 100 to 100BASE FX Fiber media conversion with integrated management The 10 100M2 conforms to Ethernet in the First Mile EFM fiber standards to support Fiber to the X FT TX Metropolitan access and Enterprise LAN networks 10 100M2 media converters are used to provide managed copper demarcation points at the customer premises and network edge offering service provisioning functions such as Quality of Service and B
5. emote Fault Detect Link Segment RFD LS Down Up Factory Default PAUS Pause Enable HDX Fiber Full Duplex Fiber Half Duplex AN MAN UTP Auto Negotiate UTP Manual 100 10 UTP 100Mbps UTP 10Mbps FDX HDX UTP Full Duplex UTP Half Duplex See Link Mode Selection Remote Fault Detect Link Propagate RFD LP Symmetrical Fault Detect SFD Asymmetrical Link Propagate P1 to P2 ALP P1 P2 See Link Mode Selection Asymmetrical Link Propagate P2 to P1 ALP P2 P1 See Link Mode Selection Asymmetrical RFD LP P1 to P2 Figure B DIP Switches 2 INSTALL STANDALONE MODULE AND CONNECT CABLES a The 10 100M2 Network Interface Device NID is available in tabletop and wall mounting models For wall mounting attach the NID to a wall backboard or other flat surfaces For tabletop installations place the unit on a flat level surface Attach the rubber feet to the bottom of the NID to prevent the unit from sliding Make sure the unit is placed in a safe dry and secure location To power the unit using the AC DC adapter connect the AC DC adapter to the AC outlet Then connect the barrel plug at the end of the wire on the AC DC adapter to the 2 5mm DC barrel connector center positive on the chassis Confirm that the unit has powered up properly by checking the power status LED located on the front of the unit To power the unit using a DC power source prepare a power cable using a two conductor in
6. sulated wire not supplied with a 14 AWG gauge minimum Cut the power cable to the length required Strip approximately 3 8 of an inch of insulation from the power cable wires Connect the power cables to the standalone unit by fastening the stripped ends to the DC power connector Connect the power wires to the DC power source The Power LED should indicate the presence of power WARNING Note the wire colors used in making the positive and negative connections Use the same color assignment for the connection at the DC power source NOTE If mounting with a safety ground attachment use the safety ground screw at the rear of the unit b When using a 10 100M2 SFP model 8919N 0 insert the SFP Fiber transceiver into the Port 1 SFP receptacle on the 10 100M2 NOTE The release latch of the SFP Fiber transceiver must be in the closed up position before insertion c Connect the UTP port via a Category 5 cable to a 10BASE T or 100BASE TX Ethernet device d Connect an appropriate multimode or single mode fiber cable to the fiber port of the installed module It is important to ensure that the transmit TX is attached to the receive side of the device at the other end and the receive RX is attached to the transmit side Single fiber SF media converter models operate in pairs The TX wavelength must match the RX wavelength at the other end and the RX wavelength must match the TX wavelength at the other end 3 CONFIGURE MODULE VIA
7. this DIP switch is in the UTP Auto Negotiate AN position factory default the UTP port automatically determines the speed and duplex mode of the connecting UTP device When the UTP AN Man DIP switch is in the Auto Negotiate AN position and the UTP 10 100 DIP switch is in the 100 position the UTP port auto negotiates to 100Mbps or 10Mbps When in the 10 position the UTP port only operates at 10Mbps When the UTP AN Man DIP switch is in the Auto Negotiate AN position and the UTP Full Half Duplex DIP switch is in the Full Duplex FDX position the UTP port auto negotiates to Full or Half Duplex When in the Half Duplex HDX position the UTP port functions only in Half Duplex SW4 UTP 10 100Mbps When the UTP AN Man DIP switch is in the manual Man position the 10 100 DIP switch determines the speed of operation for the UTP port SW5 UTP FULL HALF DUPLEX When the UTP AN Man DIP switch is in the manual Man position the UTP Full Half Duplex FDX HDX DIP switch determines the duplex operation mode of the UTP port SW6 SW7 SW8 LINK MODES The module supports multiple link modes for fault detection and isolation Link Segment should be used for the initial installation of the module Once installed and operational the link mode can be modified SW7 SW8 Link Mode Selection Down Down Link Segment LS Factory Default ia ance Link Propagate LP R

Download Pdf Manuals

image

Related Search

Related Contents

VAG K2 device User Manual Version: 4.0  05088 delta-xt baby-foot instructions d`assemblage - Migros  Micro RPM    SAMABA3G - User's Manual  PFP13077 2630 Documentation.book  Manuel d`installation et d`entretien Détecteur  20 - Club Français du Refendu  

Copyright © All rights reserved.
Failed to retrieve file