1. 8 Repeat Steps 4 through 7 for remaining mounting hole Steel Stud Drywall Plastic Ca Mounting holes centered on stud Figure 9 4 Hold metal channel on anchor flat alongside plastic straps and slide channel through hole See Figure 10 Drywall Plastic sie N Plastic Straps Anchor Metal Channel SIDE VIEW Figure 12 Figure 10 5 Holding plastic straps on anchor B pull anchor away from wall until channel rests flush behind wall making sure anchor channel is positioned vertically on stud See Figure 11 6 Slide plastic cap on anchor B towards wall until flange of cap is flush with wall See Figure 11 KSA 1020 Installation Instructions 9 Place mounting bracket over anchors and align mounting holes in mounting bracket with holes in anchors See Figure 13 10 Insert 1 4 20 x 1 3 4 Phillips pan head screw E into mounting hole on mounting bracket and into anchor B and tighten until flush against mounting bracket DO NOT overtighten See Figure 13 11 Repeat Steps 9 and 10 for remaining mounting hole Steel Stud Drywall ov E x2 N Figure 14 3 Move flag to closed position in order to fully secure mount to bracket See Figure J Mounting
2. For desk mounting proceed to Installing to Desk section Installing to Wood Studs 1 Determine location for mount keeping in mind CPU size and safety requirements 2 Use the removed mounting bracket as a template and mark through top and bottom holes of wall bracket See Figure 7 3 Drill two 7 64 diameter pilot holes at marked spots into wood stud See Figure 7 mounting bracket Figure 7 4 Install two 12 x 2 1 2 Phillips wood screws G through bracket and drywall into wood stud See Figure 7 5 Ensure bracket is vertical then tighten screws NOTE Proceed to Mounting CPU to Wall section to complete installation KSA 1020 Installation Instructions Site Requirements for Using Steel Studs WARNING IMPROPER INSTALLATION CAN LEAD TO EQUIPMENT FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT The figure below identifies the minimum requirements for installation of display mounts onto a steel stud structure If the structure or its components do not meet these requirements contact the mount manufacturer for specific instructions before attempting installation lt should also be noted that no other equipment should be mounted to the same stud 16 or 24 on center Studs Mount Installation Location Must be centered on stud If back side of wall is unfinished drywall must be installed to a minimum of one stud left and right of the stud s bein
3. to be inserted for mounting See Figure 5 NOTE Top and bottom knobs can be removed and inserted into the front square holes in order to allow for large CPU s to be installed See Figure 5 NOTE Flanges may be reversed in order to allow for narrow CPU s to be installed in a secure manner If this is done be sure to also remove and reinstall strap so that the buckle is facing out for easy adjustment Figure 5 6 Set CPU in CPU mount A See Figure 6 7 Use adjustment knobs to compress mount around CPU until CPU is tightly secured in mount A See Figure 6 y gt NN ATI SN o Figure 6 8 Tighten front strap to desired tension WALL MOUNT INSTALLATION WARNING FAILURE TO PROVIDE ADEQUATE STRUCTURAL STRENGTH FOR THIS MOUNT CAN RESULT IN SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT It is the installer s responsibility to make sure the structure to which this mount is attached can support five times the combined weight of the mount and all equipment attached to it Reinforce the structure as required before installing the mount NOTE Mount may be installed using 2 x 4 wood studs steel studs or it may be installed directly into drywall For steel stud and drywall installation proceed to Site Requirements for Using Steel Studs section
4. Bracket Anchor Metal Channel S SIDE VIEW Figure 13 O Installing CPU Mount to Wall CAUTION Overtightening screws may cause wall bracket to compress into soft wall surface resulting in difficult mount installation 1 Ensure bracket flag is in the open position See Figure O S7 2 Insert mounting buttons into the four large mounting holes on the bracket and lower into place See Figure 14 23 2 OD Latch closed rear view Latch open Figure 15 Installation Instructions KSA 1020 Installing Mount to Desk WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the desk to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component NOTE The following instructions are for mounting with full 360 swivel capability for easy cord access If this capability is not desired connect mounting bracket using two screws as demonstrated in the Installing to Wood Studs section 1 Determine location for mount keeping in mind CPU size and safety requirements 2 Using bracket and swivel bearing D as a template mark and drill one 17 64 diameter pilot hole through underside of des
5. INSTALLATION INSTRUCTIONS Wall and Desk CPU Mount S CHIEF KSA 1020 Our Mounts Your KSA 1020 Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries collectively Milestone intend to make this manual accurate and complete However Milestone makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document Chief is a registered trademark of Milestone AV Technologies All rights reserved A IMPORTANT WARNINGS AND CAUTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions DIMENSIONS WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory
6. U SURFACE 109 4 29 Installation Instructions KSA 1020 LEGEND Tighten Fastener Apretar elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Pencil Mark Marcar con lapiz Stiftmarkierung Marcar com lapis Segno a matita Potloodmerkteken Marquage au crayon Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella a y Kruiskopschroevendraaier Tournevis pointe cruciforme Open Ended Wrench Llave de boca Gabelschl ssel Chave de bocas Chiave a punte aperte Steeksleutel Cl fourche TOOLS REQUIRED FOR INSTALLATION 4 7 64 17 64 1 2 1 2 2 A 1 E 2 1 4 20 x xa A LL C 4 DE 3 8 x 1 1 4 4 Rubber edger 3 D 1 Swivel bearing G 2 12 x 2 1 2 KSA 1020 I
7. g used to install the mount Drywall must be secured to studs with screws 12 on center There must be a minimum of 1 7 8 48mm clearance inside wall Drywall 1 2 minimum Drywall Thickness Both Sides of Stud See Hazard statement on page 2 Steel Stud 2 x 4 25ga minimum Stud type and structural strength must conform to the North American Specification for the Design of Cold Formed Steel Structural Members 362 S 125 18 C Shaped S Stud Section Figure 8 Installation Instructions KSA 1020 Installing to Steel Studs or Drywall Steel Stud WARNING IMPROPER INSTALLATION CAN LEAD TO Drywall EQUIPMENT FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT 1 Determine location for mount keeping in mind CPU size and Plastic Cap safety requirements 2 Use the removed mounting bracket as a template and mark through top and bottom holes of wall bracket making sure mounting holes are centered on stud See Figure 9 Ga gt gt 3 Drilltwo 1 2 diameter pilot holes at marked spots into wood stud See Figure 9 x 2 Anchor Metal Channel Side View 00O Figure 11 7 Snap off plastic straps on anchor at wall by pushing side to side snapping off straps level with flange of plastic cap See Figure 12
8. k at desired mounting location Ensure entire mount will clear the outer edge of desk See Figure 16 Desk Mounting bracket Figure 16 3 Install 3 8 x 1 1 4 hex head lag screw F through bearing D and mounting bracket into hole drilled in Step 2 See Figure 16 Ensure bracket flag is in the open position See Figure 15 Insert four mounting buttons into four mounting holes on the bracket See Figure 17 Latching flag desk not shown 6 Figure 17 Slide buttons into locked position within holes Move flag to closed position in order to fully secure mount to bracket See Figure KSA 1020 Installation Instructions 10 Installation Instructions KSA 1020 11 KSA 1020 Installation Instructions S CHIEF Our Mounts Your Vision Chief Manufacturing a products division of Milestone AV Technologies 8834 002003 Rev00 2011 Milestone AV Technologies a Duchossois Group Company www chiefmfg com 05 11 USA International Europe Asia Pacific gt TU 8401 Eagle Creek Parkway Savage MN 55378 800 582 6480 952 894 6280 877 894 6918 952 894 6918 Fellenoord 130 5611 ZB EINDHOVEN The Netherlands 31 0 40 2668620 31 0 40 2668615 Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong 852 2145 4099 852 2145 4477 a
9. nstallation Instructions ASSEMBLY Installation of Protective Rubber Edging 1 Place four strips of protective rubber edging C over the sharp edges located on the top and bottom of the mount A See Figure 1 Figure 1 CPU Installation 1 Release bracket from mount by moving flag to open position See Figure 2 2 Remove bracket from mounting buttons on back of mount See Figure 2 If hanging mount underneath desk remove mounting buttons to reinstall them in the holes in which they will be used If mounting vertically move mounting buttons to the four holes on top of the mount See Figure 3 If mounting horizontally move mounting buttons to the top four holes on the back See Figure 3 Vertical button location Horizontal button location Figure 3 4 Loosen adjustment knob at the back of the mounting unit and adjust height of mount to a height greater than the height of the CPU Loosen strap at the front of the mount if necessary See Figure 4 Latch closed Latch open Strap Figure 2 Figure 4 Installation Instructions KSA 1020 5 Loosen adjustment knobs on top and bottom of the mount and slide flanges in order to allow for the CPU
10. warranty It is the installer s responsibility to make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component The wall to which the mount is being attached may have a maximum drywall thickness of 5 8 1 6cm Do not install drywall anchors into the seam between drywall pieces WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components attached to this accessory does not exceed 40 Ibs 18 1 kg UN DER DESKMWOUNTEDCONFIGY 0 N LY AVAILABLE WITH CSA 1020 HO N POT AT AULD WITH KY RA PR 1 11 10 N DICI O ALLINOMEMORKSTATION Br LI ni ni CRI WALL MOUNTED CONFIGURATION 9 75 18 00 HEIGHT OF CPURANGE 0 191 1 50 WIDTH OF CPU RANGE 38 1 50 MOUNTING SURFACE TO CP
Download Pdf Manuals
Related Search
Related Contents
- Solarclarity Rennes connection integrale.qxd Samsung SAMSUNG PL150 Uporabniški priročnik 家庭 - ELPA 朝日電器株式会社 Tableau de gestion des archives Ministère de l`Agriculture et de la 取扱説明書 - オフィスチェアブランド BAUHUTTE(バウヒュッテ) GalaRio 1.1 User`s Guide Telular 1X User's Manual 4646 Adapter Kit 7-3465 (I).p7.0 SPA LoTUS MANUEL D`INSTALLATIoN ET D Copyright © All rights reserved.