Home

Datalogic 94A151107 mobile device charger

image

Contents

1. interference and 2 this device must accept any interference received including interference which may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 822000692 Rev B DATALOGIC Kyman NET Vehicle Cradle The Kyman NET Vehicle Cradle allows charging the Kyman NET mobile computer battery and holding it securely in your vehicle It also functions as a serial communication interface between a Host typically a Laptop PC and the RS232 contacts on the mobile computer gt Microphone Loudspeaker os Ext Microphone Headset Jack LED Indicator Mobile Computer Contacts A upu Mounting Holes G Adhesive Stylus Holder Power Connector Jack RS232 Connector Figure 1 Kyman NET Vehicle Cradle External microphone headset jack microphone and speaker allow managi
2. ACCESSORIES 94A051013 WIN NET VEHICLE POWER Cable containing an 8A slow blow fuse for powering CAB CRADLE the vehicle cradle from the car cigarette lighter 94ACC1306 ADJUSTABLE ARM KIT FOR positionable arm for mounting the cradle in the VEHICLE CRADLE vehicle TECHNICAL FEATURES Kyman NET Vehicle Cradle Electrical Features Power Supply from 10 to 32 VDC Consumption with mobile computer Max 1 8A Quiescent Consumption Max 5mA without mobile computer Indicators Power on LED green Charge Time Li when mobile computer is off Communication Features Interface RS232 Baud Rate up to 115200 b sec Environmental Features Working Temperature 20 to 50 C 4 to 140 F Storage Temperature 20 to 70 C 4 to 158 F Humidity 90 non condensing Degree of Protection IP20 Vibration Resistance EN60068 2 64 frequency range 5 1000 Hz acceleration RMS 3 1 g initial slope 26dB oct 5 10 Hz final slope 3dB oct 10 1000 Hz Shock Resistance EN60068 2 29 25g 6ms duration 500 shock impacts Battery must be charged at a temperature ranging from 0 to 45 C 32 to 113 F lon Battery max 2 5 hours FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use this equipment The device complies with PART 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful
3. ng a vocal communication see related paragraph on next page MOUNTING THE KYMAN NET VEHICLE CRADLE The Kyman NET Vehicle Cradle can be mounted to the desired surface using the 4 screws together with the 4 nuts Figure 2 Mounting the Kyman NET Vehicle Cradle POWERING THE KYMAN NET VEHICLE CRADLE CONNECTION Once the cradle has been mounted it is necessary to prepare the power cable termination to connect the The Kyman NET Vehicle Cradle can be connected to a host by means of an RS232 interface cradle to the vehicle power source Brown wire connect to a V 10 to 32 Vdc vehicle power source Blue wire connect to the vehicle ground wire or chassis ground RS232 Connection The Kyman NET Vehicle Cradle can be connected to the host by means of any standard null modem Green Yellow wire not connected cable A 9 pin female D Sub connector must be connected to the RS232 port of the cradle Once the host has been turned on insert the Kyman NET mobile computer into the cradle For connection to the vehicle power source it is Pues Pin 9 of the Vehicle Cradle RS232 connector normally not connected in null modem cables supplies possible to use the in line fuse with holder regulated 5 Vdc 5 500 mA max power supplied with the cradle lt gt Host Computer Verify that the a 8 A slow blow fuse is contained within the holder then splice it to the end of the i Fi 3 F Hold brown wi
4. nication takes place through the Kyman NET Mobile Computer integrated mobile computer loudspeaker and microphone Once inserted into the vehicle cradle the communication has to be managed by the cradle itself Thus the mobile computer must be configured through the volume settings applet available in the Windows CE NET control panel to correctly manage the communication refer to the Kyman NET User s Manual for more details Vocal Communication requires Kyman NET Mobile Computer SW version 1 34 or later Figure 6 Extracting the Mobile Computer from the Kyman NET Vehicle Cradle
5. re of the cable Make the distance ute PUSO MONIGI between fuse holder and power connection point as Brown Wire short as possible and apply a caution label on the Kyman NET vA Standard Null fuse holder Vehicle Cradle HH Modem Cable Once the power cable termination has been Figure 4 Fuse Holder Connection EFH ET completed it is possible to connect the Kyman To Vehicle Battery NET Vehicle Cradle to the vehicle power INSERTING THE KYMAN NET INTO THE VEHICLE CRADLE Ei eee OUeeeuoe For correct functioning first insert the Pinout mobile computer into the cradle Then push it towards the upper part of the cradle The Null Modem Cable allowing the RS232 connection has the following pinout until the retaining roller clicks Cradle side Host PC side 9 pin D sub 9 pin D sub male b n female 1 o am 7 8 lt CTS 24 RXD 3 When the cradle is powered insert the mobile computer and the green LED will turn on If the mobile computer is not 5 E 5 inserted the LED remains off while the 6 lt 4 cradle is still powered 7 RTS gt gt 5 V Figure 5 Inserting the Mobile Computer into the Kyman NET Vehicle Cradle 3 2 Figure 8 Null Modem Cable Pinout EXTRACTING THE KYMAN NET FROM THE VEHICLE CRADLE CONFIGURING KYMAN NET MOBILE COMPUTER FOR VOCAL COMMUNICATION To extract Kyman NET push the clip of the retaining roller up and extract the By default vocal commu

Download Pdf Manuals

image

Related Search

Related Contents

Plant RNA/DNA Purification Kit - Protocol  Model 835-3 User`s Manual - Berkeley Nucleonics Corporation  Philips Bulb 925694145503  DENVER BPB-100C - Besøg masterpiece.dk      CP500 Manual do Utente Portuguese  MOB1 user manual  manual CEP todas as linguas c  Model 2188 Turntable 1.2-m, 1.5-m, 2.0-m - ETS  

Copyright © All rights reserved.
Failed to retrieve file