Tripp Lite SmartPro 120V 700VA 450W Line-Interactive Sine Wave UPS, Dual Voltage, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial
Contents
1. Since the runtime performance of all UPS bat teries will gradually deplete over time it is recommended that you periodically perform a self test see MUTE TEST Button description to determine the energy level of your UPS batteries BEFORE a blackout or severe brownout occurs During a prolonged blackout or severe brownout you should save files and shut down your equipment since battery power will eventually be depleted When the LED turns red and an alarm sounds continuously it indicates the UPS s batteries are nearly out of power and UPS shutdown is imminent BATTERY WARNING LED this LED lights red and an alarm sounds inter mittently after you initiate a self test see MUTE TEST Button description to indicate the UPS batteries need to be recharged or replaced Allow the UPS to recharge continuously for 12 hours and repeat the self test If the LED contin ues to light contact Tripp Lite for service If your UPS requires battery replace ment visit www tripplite com to locate the specific Tripp Lite replacement bat tery for your UPS 4 200511135 93 2513 SMART700DV OM qxd pos 3 28 PM Page 7 Basic Operation continued Other UPS Features Rear Panel E 15 amp 120V NEMA 5 15R E LO po AC Receptacles Your UPS features 15 amp AC outlets These output recep tacles provide your connected equipment with AC line power du
2. 200511135 93 2513 SMART700DV OM qxd pos 3 28 PM Page 1 POwner s Manual SMART700DV Intelligent Line Interactive UPS System e 120V 230V Auto Sensing Input 120V Output Not suitable for mobile applications Test mply With lards FOR HOME OR OFFICE USE important Safety Instructions gt CT gt CT TA Base Operat Storage anasomiee O baton Repiacemen CTN 1 TEN TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com Copyright 2006 Tripp Lite All rights reserved 4 200511135 93 2513 SMART700DV OM qxd gong 3 28 PM Page 2 Important Safety Instructions VAN SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during the installation operation and storage of all Tripp Lite UPS Systems Failure to heed these warnings will void your warranty UPS Location Warnings The UPS is heavy Use caution when lifting it Install your UPS indoors away from excess moisture or heat dust or direct sunlight e For best performance the ambient temperature near your UPS should be between 0 C and 40 C between 32 F and 104 F Leave adequate space around all sides of the UPS for proper ventilation Do not obstruct its vents or fan openings UPS Connection Warnings e The UPS contains its own energy source battery The output terminals may be live even when the UPS is not co
3. ON see Step 3 below The BATTERY CHARGE LED will be the only LED illuminated El Plug your equipment into the UPS NOTE Your UPS is designed to support only elec tronic equipment You will overload the UPS if the total VA ratings for all the equipment you connect exceeds the UPS s Output Capacity 700VA To find your equipment s VA ratings look on their name plates If the equipment is listed in amps multiply the number of amps by 120 to determine VA Example 1 amp x 120 120 VA If you are unsure if you have overloaded the UPS s outlets see OUTPUT LOAD LEVEL LED description Ej Turn the UPS ON Press and hold the ON OFF STANDBY button for one second The alarm will beep once briefly after one second has passed Release the button 200511135 93 2513 SMART700DV OM qxd pos 3 28 PM Page 4 Optional Installation These connections are optional Your UPS will function properly without these connections E USB and RS 232 Serial Communications Use the included USB cable see E and or DB9 serial cable see D to connect the communication port on your equipment to the communication port of your UPS Install on your equipment the Tripp Lite PowerAlert Software appropriate to your equipment s operating system Consult your PowerAlert manual for more information H EPO Port Connection This optional feature is only for those applications which reguire conn
4. a self test may cause the UPS to shut down and cease supplying output power in the event of a blackout or brownout If the BATTERY WARNING LED remains lit and the alarm continues to sound after the test the UPS batteries need to be recharged or replaced Allow the UPS to recharge continuously for 12 hours and repeat the self test If the LED remains lit contact Tripp Lite for service If your UPS requires battery replacement visit www tripplite com to locate the specific Tripp Lite replacement battery for your UPS The alarm will beep once briefly after the indicated interval has passed 4 200511135 93 2513 SMART700DV OM qxd gong 3 28 PM Page 6 Basic Operation continued Indicator Lights Front Panel All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned ON POWER LED this green LED lights continuously when the UPS is ON and supplying connected equipment with AC power from a utility source The LED flashes and an alarm sounds 4 short beeps followed by a pause to indicate the UPS is operating from its internal batteries during a blackout or severe brownout If the blackout or severe brownout is prolonged you should save files and shut down your equipment since internal battery power will eventually be depleted See BATTERY CHARGE LED description below VOLTAGE CORRECTION LED this green LED lights continuously whenever the UPS is automatically correctin
5. cts Input Breaker Protect your electrical circuit from overcurrent draw from the UPS load If this breaker trips remove some of the load then reset it by pressing the breaker in 200511135 93 2513 SMART700DV OM qxd gong 3 28 PM Page 8 Storage and Service Storage Before storing your UPS turn it completely OFF with the UPS ON and receiving utility power press and hold the ON OFF STANDBY button for one second an alarm will beep once briefly after the interval has passed then unplug the UPS from the wall outlet If you store your UPS for an extended period of time recharge the UPS batteries once every three months plug the UPS into a wall outlet allow it to charge for 12 hours then unplug it and place it back in storage Note after you plug the UPS in it will automatically begin charging its batteries however it will not supply power to its outlets see Quick Installation section If you leave your UPS batteries discharged for an extended period of time they will suffer a permanent loss of capacity Service Before returning your UPS for service follow these steps 1 Review the installation and operation instructions in this manual to ensure that the service problem does not originate from a misreading of the instructions 2 If the problem continues do not contact or return the UPS to the dealer Instead call Tripp Lite at 773 869 1233 A service technician will ask for the UPS s model number serial number and
6. de will automatically charge its batteries but will not supply power to its outlets until it is turned ON The alarm will beep once briefly after the indicated interval has passed If fully charged MUTE TEST Button To Silence or Mute UPS Alarms briefly press and release the MUTE TEST button To Run a Self Test with your UPS plugged in and turned ON press and hold the MUTE TEST button for two seconds Continue holding the button until the alarm beeps several times and the UPS performs a self test See Results of a Self Test below Note you can leave connected equipment on during a self test Your UPS however will not perform a self test if the UPS is not turned on see ON OFF STANDB Y Button description CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical grounding and may introduce a damaging surge into your network connections Results of a Self Test The test will last approximately 10 seconds as the UPS switches to battery to test its load capacity and battery charge If the OUTPUT LOAD LEVEL LED remains lit red and the alarm continues to sound after the test the UPS s outlets are overloaded To clear the overload unplug some of your equipment and run the self test repeatedly until the OUTPUT LOAD LEVEL LED is no longer lit red and the alarm is no longer sounding CAUTION Any overload that is not corrected by the user immediately following
7. ection to a facility s Emergency Power Off EPO circuit When the UPS is connected to this circuit it enables emergency shutdown of the UPS s inverter Using the cable provided connect the EPO port of your UPS see EJ toa user supplied normally closed or normally open switch according to the circuit diagram see EJ The EPO port is not a phone line surge sup pressor do not connect a phone line to this port OPTION 1 USER SUPPLIED NORMALLY CLOSED SWITCH 45 JUMPER y k N C EPO SWITCH NO CONNECTION USER SUPPLIED NORMALLY OPEN SWITCH NO EPO SWITCH O EE 2 NO CONNECTION 200511135 93 2513 SMART700DV OM qxd pos 3 28 PM Page 5 Basic Operation Buttons Front Panel ON OFF STANDBY Button To turn the UPS ON with the UPS plugged into a live AC wall outlet press and hold the ON OFF STANDBY button for one second Release the but ton If utility power is absent you can cold start the UPS i e turn it ON and supply power for a limited time from its batteries by pressing and holding the ON OFF STANDB Y button for one second To turn the UPS OFF with the UPS ON and receiving utility power press and hold the ON OFF STANDB Y button for one second Then unplug the UPS from the wall outlet The UPS will be completely OFF After you plug the UPS into a live AC outlet the UPS in Standby mo
8. g high or low AC voltage on the utility line without the assistance of battery power The UPS will also emit a slight clicking noise These are normal automatic operations of the UPS no action is required on your part QUTPUT LOAD LEVEL LED this multicolored LED indicates the approximate electrical load of equipment connected to the UPS s AC outlets It will turn from green light load to yellow medium load to red overload If the LED is red either illuminated continuously or flashing clear the overload immediately by unplugging some of your equipment from the outlets until the LED changes from red to yellow or green CAUTION Any overload that is not corrected by the user immediately may cause the UPS to shut down and cease supplying output power in the event of a blackout or brownout BATTERY CHARGE LED when the UPS is operating from utility power this LED indicates the approximate charge state of the UPS s internal batteries red indicates the batteries are beginning to charge yellow indicates the batteries are roughly midway through charging and green indicates the batteries are fully charged When the UPS is operating from battery power during a blackout or severe brownout this LED indicates the approximate amount of energy ulti mately affecting runtime which the UPS s batteries will provide red indicates a low level of energy yellow indicates a medium level of energy and green indicates a high level of energy
9. nce at his own expense The user must use shielded cables and connectors with this product Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification your Tripp Lite product has been assigned a unique series number The series number can be found on the product nameplate label along with all required approval markings and information When requesting compliance information for this product always refer to the series number The series number should not be con fused with the marking name or model number of the product Note on Labeling Two symbols are used on the label V AC Voltage V DC Voltage Warranty Registration Visit www tripplite com warranty today to register the warranty for your new Tripp Lite product You ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product No purchase necessary Void where prohibited Some restrictions apply See website for details 200511135 93 2513 SMART700DV OM qxd pos 3 28 PM Page 11 200511135 93 2513 SMART700DV OM qxd gong 3 28 PM Page 12 TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com 4 200511135 93 2513
10. nel using the same number and type of batteries sealed Lead Acid The batteries are recyclable Refer to your local codes for disposal requirements or in the USA only call 1 800 SAV LEAD or 1 800 8 BATTERY 1 800 822 8837 or visit www rbrc com for recycling information Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges R B C Visit Tripp Lite on the Web at www tripplite com to locate the specific replacement battery for your UPS During hot swap battery replacement the UPS will not provide backup power in the event of a blackout or other power interruptions Do not operate UPS without batteries 200511135 93 2513 SMART700DV OM qxd pos 3 28 PM Page 3 Quick Installation El Plug the UPS into a wall outlet supplying either 120V or 230V nominal AC power Use the included detachable power cord The IEC 320 end connects to the AC input receptacle on the rear of the UPS the NEMA 5 15 end connects to the wall outlet To plug the UPS into a wall outlet that does not accept a NEMA 5 15 plug simply replace the included power cord with a detachable cord from another piece of equipment such as a computer Then use the includ ed power cord to connect the equipment to the UPS NOTE After you plug the UPS into a live AC outlet the UPS in Standby mode will automatically charge its batteries but will not supply power to its outlets until it is turned
11. nnected to an AC supply e Connect your UPS to a properly grounded AC power outlet Do not modify the UPS s plug in a way that would eliminate the UPS s connection to ground Do not use adapters that eliminate the UPS s connection to ground Do not plug your UPS into itself this will damage the UPS and void your warranty If you are connecting your UPS to a motor powered AC generator the generator must provide filtered frequency regulated computer grade output Connecting your UPS to a generator will void its Ultimate Lifetime Insurance Equipment Connection Warnings Do not use Tripp Lite UPS Systems for life support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors or extension cords to the output of your UPS This might overload the UPS and will void the surge suppressor and UPS warranties Battery Warnings Batteries can present a risk of electrical shock and burn from high short circuit current Observe proper precautions Do not dispose of the batteries in a fire Do not open the UPS or batteries Do not short or bridge the battery terminals with any object Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles There are no user serviceable parts inside the UPS Battery replacement should be performed only by authorized service person
12. purchase date and will attempt to correct the problem over the phone 3 If the problem requires service the technician will issue you a Returned Material Authorization RMA number which is required for service If you require packaging the technician can arrange to send you proper packaging Securely pack the UPS to avoid damage during ship ping Do not use Styrofoam beads for packaging Any damages direct indirect special inci dental or consequential to the UPS incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under warranty UPS Systems shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid Mark the RMA number on the outside of the package If the UPS System is within the 2 year warranty period enclose a copy of your sales receipt Return the UPS for service using an insured car rier to the address given to you by the Tripp Lite service technician 200511135 93 2513 SMART700DV OM qxd pos 3 28 PM Page 9 Battery Replacement Under normal conditions the original batteries in your UPS will last many years See Safety section before replacing batteries The batteries are designed for hot swap replacement i e leaving the UPS in ON mode but some qualified service personnel may wish to put the UPS in the OFF mode and disconnect equipment before proceeding Procedure El Remove Front Panel B Disconnect Batteries E Remove Dispose of Ba
13. ring normal operation and battery power during blackouts and brownouts The UPS protects equipment connected to these receptacles against damaging surges and line noise If you have a serial or USB connection to your UPS you can remotely reboot connected equipment by turning the receptacles OFF and ON using Tripp Lite s PowerAlert Software Communications Ports USB or RS 232 These ports connect your UPS to any workstation or server Use with Tripp Lite s PowerAlert Software and included cables to enable your computer to automatically save open files and shut down equipment during a blackout Also use PowerAlert Software to monitor a wide variety of AC line power and UPS operating conditions Consult your PowerAlert Software manual or contact Tripp Lite Customer Support for more information See USB and RS 232 Serial Communications in the Optional Installation section for installation instructions EPO Emergency Power Off Port Your UPS features a EPO port that may be used to connect the UPS to a contact closure switch to enable emergency inverter shutdown See Optional Installation Accessory Slot Remove the small cover panel from this slot to install optional accessories to remotely monitor and control your UPS Refer to your accessory s manual for installation instructions Contact Tripp Lite Customer Support at 773 869 1234 for more information including a list of available SNMP network management and connectivity produ
14. tteries El Ada Batteries El Connect Batteries Attach connectors black to black and red to red D Replace Front Panel 200511135 93 2513 SMART700DV OM gxd 1 2006 3 28 PM Page 10 Model SMART700DV Input Voltage 120V or 230V AC nominal auto sensing Input Frequency 50 or 60 Hz auto sensing Input Receptacle IEC 320 C14 Accepts detachable power cords Included cord features NEMA 5 15 plug Output Voltage 120V AC Output Frequency 50 or 60 Hz Output Capacity VA 700 Output Capacity Watts 450 Output Receptacles 6 NEMA 5 15R Communications Ports 1 USB 1 RS 232 Emergency Power Off EPO Port 1 The policy of Tripp Lite is one of continuous improvement Specifications are subject to change without notice This product designed and engineered in the USA FCC RADIO TV INTERFERENCE NOTICE Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when operated in a commercial environ ment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications Operation of this equipment is likely to cause harmful interference in which case the user will be required to correct the interfere
Download Pdf Manuals
Related Search
Related Contents
Kenmore 21 cu. ft. Counter-Depth Side-by-Side Refrigerator - Black Manufacturer's Warranty 6` x 6` x 6` Shed-in-a-Box® Assembly Instructions MANUEL D`INSTRUCTIONS VKM-GB(M) DeviceNet P.54A-39 - Evo X Service Manuals Téléchargez notre notice d`utilisation ici (48Ko, PDF) Operation Manual Copyright © All rights reserved.