Home

APC Rack PDU,Basic, Zero U,5.7kW,120&208V

image

Contents

1. www apc com Rack Power Distribution Unit AP7562 AP7563 AP7564 General Information Description This booklet provides information on installing and operating the Rack Power Distribution Units PDUs AP7562 AP7563 and AP7564 o SSS2SS262EE5 ESRB Sass gt 3 9 J al J BSSe222 2225222222222 SARARIR SS5565585559 i AP7562 AP7563 AP7564 42 NEMA 5 20 outlets 21 NEMA 5 20 outlets 36 IEC 320 C13 outlets 6 NEMA L6 20 outlets 6 IEC 320 C19 outlets NEMA L21 20 plug NEMA L21 20 plug NEMA L21 20 plug General Information Inventory for AP7562 and AP7564 Quantity 3 Item Cord retention tray with 12 flat head screws and 48 wire ties Mounting brackets with 4 flat head screws Warranty registration card Inventory for AP7563 Quantity Item 2 Cord retention tray with 8 flat head screws and 24 wire ties 2 Mounting brackets with 4 flat head screws 1 Warranty registration card Receiving inspection Inspect the package and contents for shipping damage and make sure that all parts were sent Report any damage immediately to the shipping agent and report missing contents damage or other problems immediately to APC or your APC reseller Please recycle later use or dispose of them appropriately fs The shipping materials are recyclable Please save them for 2 Rack Power Distribution Unit AP7562 AP7563 A
2. Rack PDU 1 Note the serial number and date of purchase The serial number is located on the bottom of the PDU 2 Contact Customer Support at a phone number located on the back cover A technician will try to help you solve the problem by phone 3 If you must return the product the technician will give you a return material authorization RMA number If the warranty expired you will be charged for repair or replacement 4 Pack the unit carefully The warranty does not cover damage sustained in transit Enclose a letter with your name address RMA number and daytime phone number a copy of the sales receipt and a check as payment if applicable 5 Mark the RMA number clearly on the outside of the shipping carton 6 Ship by insured prepaid carrier to the address provided by the Customer Support technician Rack Power Distribution Unit AP7562 AP7563 AP7564 Life Support Policy General policy Examples of life support devices American Power Conversion APC does not recommend the use of any of its products in the following situations In life support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to affect significantly its safety or effectiveness In direct patient care APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that a the ri
3. 7 Warranty and Service Limited warranty Warranty limitations Obtaining service APC warrants the Rack PDU to be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser Except as provided herein APC makes no warranties express or implied including warranties of merchantability and fitness for a particular purpose Some jurisdictions do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser Except as provided above in no event will APC be liable for direct indirect special incidental or consequential damages arising out of the use of this product even if advised of the possibility of such damage Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise This warranty gives you specific legal rights and you may also have other rights which vary according to jurisdiction To obtain support for problems with your
4. P7564 How to Install the Rack PDU Attach the cord Attach the cord retention trays to the Rack PDU using four flat head retention trays screws provided per tray Attach cords to the tray Attach a cord to the tray by looping the cord and securing it to the tray using a wire tie provided unplug it from the Rack PDU without removing the wire tie Q Each cord must be secured to the tray so that you can Note Rack Power Distribution Unit AP7562 AP7563 AP7564 How to Install the Rack PDU Mounting options You can install the Rack PDU in one of two ways using toolless mounting pegs provided or the mounting brackets provided To install the Rack PDU using the toolless mounting method install it in the rear of the NetShelter VX Enclosure in the cable channel directly behind the rear vertical mounting rails e To install the Rack PDU using the mounting brackets install it on a vertical mounting rail on your rack or enclosure Toolless mounting 1 Slide the mounting pegs into the holes located in the channel in the rear panel of the enclosure 2 Snap the Rack PDU into place by pushing it downward until it locks into position Q You can mount two Rack PDUs on one side of the enclosure by using the toolless mounting method Note 4 Rack Power Distribution Unit AP7562 AP7563 AP7564 How to Install the Rack PDU Bracket moun
5. r support information www apc com support Global support searching APC Knowledge Base and using e support e Contact an APC Customer Support center by telephone or e mail Regional centers Direct InfraStruXure Customer Support 1 877 537 0607 toll free Line APC headquarters U S Canada 1 800 800 4272 toll free Latin America 1 401 789 5735 USA Europe Middle East Africa 353 91 702000 Ireland Japan 0 35434 2021 Australia New Zealand South Pacific 61 2 9955 9366 Australia area Local country specific centers go to www apc com support contact for contact information Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support Entire contents copyright 2004 American Power Conversion All rights reserved Reproduction in whole or in part without permission is prohibited APC the APC logo InfraStruXure and NetShelter are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions All other trademarks product names and corporate names are the property of their respective owners and are used for informational purposes only PANGA AOAO NYA pao InfraStruXure APC
6. sks of injury or damage have been minimized b the customer assumes all such risks and c the liability of American Power Conversion is adequately protected under the circumstances The term life support device includes but is not limited to neonatal oxygen analyzers nerve stimulators whether used for anesthesia pain relief or other purposes autotransfusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dialysis systems neonatal ventilator incubators ventilators for adults and infants anesthesia ventilators infusion pumps and any other devices designated as critical by the U S FDA Hospital grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems APC does not claim that units with these modifications are certified or listed as hospital grade by APC or any other organization Therefore these units do not meet the requirements for use in direct patient care Rack Power Distribution Unit AP7562 AP7563 AP7564 9 APC www apc com APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways e Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests www ape com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides custome
7. ting To mount the Rack Rack PDU vertically in a NetShelter or any standard EJA 310 rack or enclosure 1 Attach the vertical mounting brackets to the Rack PDU aus Rack Power Distribution Unit AP7562 AP7563 AP7564 5 How to Install the Rack PDU 2 Install the Rack PDU on a vertical mounting rail in your rack or enclosure Q Q Q Q Q D Q a Q Q Q Q D D Q Q 6 Rack Power Distribution Unit AP7562 AP7563 AP7564 Specifications Electrical AP7562 AP7563 AP7564 Nominal input voltage 120V 120V or 208 V 208V Acceptable input voltage 10 Nominal input voltage Input frequency 47 63 Hz Cord length 3 ft Input connectors NEMA L21 20 plug Output connectors 42 NEMA 5 20 21 NEMA 5 20 36 IEC 320 C13 outlets 6 NEMA L6 20 6 IEC 320 C19 outlets outlets Maximum total current draw 16 A per Phase Physical Size H x W x D 70 00 x2 19x 1 73 in 177 80 x5 56x4 39 cm Weight 12 Ib 5 44 kg Shipping weight 19 5 Ib 8 85 kg Environmental Elevation above MSL Operating 0 15000 ft 0 4500 m Storage 0 50000 ft 0O 15000 m Temperature Operating 5 to 45 C 23 to 115 F Storage 25 to 65 C 13 to 149 F Humidity Operating 5 95 RH Non condensing Storage 5 95 RH Non condensing Compliance Safety verification UL cUL 60950 Rack Power Distribution Unit AP7562 AP7563 AP7564