Home
APC Condenser 1 EC Fan
Contents
1. e s Transformers 3 User interface connectors 4 M Main controller board Relay board Ground lug N Main circuit breaker power feed A Main circuit breaker power feed B Automatic transfer switch ATS contactors ATS timers ATS transformer 501 only ATS timer circuit breakers Fan circuit breakers Controller circuit breaker Humidifier circuit breaker Heater circuit breaker Heater contactors 00 e e e o e e o o o o o o o o o Humidifier contactor eje eje e e e eje eje e e s e e e e e e o Bi ge gem OG SEET Fe InRow RP Technical Data Manual Air cooled Electrical Panel Note ACRP 101 shown Transformers User interface connectors Main controller board Relay board Ground lug Main circuit breaker Compressor fu
2. 176 6 91 FRONT COLD AISLE Dimensions are shown in mm in Water supply to chiller Water supply from chiller Condensate overflow Communication connections 27 80 mm 1 09 in Power connections dual feed Condensate drain Humidifier supply InRow RP Technical Data Manual 31 Air cooled Piping Diagram Bottom piping Top piping Mc Condenser Condenser Hot gas Hot gas na2543a RP Receiver RP Receiver 7 Note Shutoff valves shown nearest to the condensers are not supplied by Pressure relief Check valve o Pitch in direction of refrigerant flow 4 mm per m 0 5 in per 10 ft valve Dex Shutoff valves K 3 P trap NG Head pressure control valve NG S trap INN Inverted P trap All lines are Type L copper tubing Note Route piping through the top or bottom of the InRow RP Note Trap the vertical discharge line every 6 m 20 ft to ensure proper oil return Note The maximum piping run is 61 m 200 ft equivalent length Size the piping pursuant to accepted refrigeration practice Warning Do not install the air cooled condenser below the indoor equipment The N condenser must be positioned above or at the same level as the equipment to ensure proper function 32 InRow RP Technical Data Manual Air cooled Piping Access top REAR HOT AISLE
3. 36 ACCD75207 1 viu I ERU EUR TEUER a nva s 37 ACCD75208 ACCD75209 37 Air cooled Condenser Features 37 Guide Specifications ooi occu OO Guidelines for Installation 44 Room preparation 44 Service dCCess 2 20 d dor aea c EL ww Er CR a e 44 Receiving the Unit 44 Rigging dinh E 44 Condensate Drain 44 ii InRow RP Technical Data Manual Overview The modular row based computer room cooling system offers efficient predictable and economical cooling for a variety of spaces Critical environmental requirements now reach far beyond the confines of the traditional data center or computer room to encompass a larger suite of applications referred to as technology rooms Critical environment applications include Computer rooms Telecommunication facilities Clean rooms Power equipment Medical equipment rooms LAN WAN environments A worldwide network of APC representatives is fully qualified to provide engineering sales installation and service for our products APC warrants all parts for 18 months from shipment and 12 months from startup Extended warranties are available Capacity The InRow RP chilled water
4. 380 14 98 2 3 CH CH 325 12 81 2 C DP PD DH DH DH D D H H D H DH D NA HS OD DH D tu gt a oO oo 177 6 97 Hug Hu Hu Hu 0 D a D Hu Hu Hu a EE EI Er EI Er EI EI EI EE E EI IEN See See d E EI Ei E EL EL E Ei E Zi EE E Er E EL Er EI E E EL E E EN na2274a 4 211 8 29 176 6 92 a FRONT COLD AISLE Dimensions are shown in mm in Chilled water supply Chilled water return Trough for communication cables Power connections dual feed Humidifier supply Condensate drain 0060000 30 InRow RP Technical Data Manual Bottom Chilled Water Piping Access bottom view looking up REAR HOT AISLE 187 7 35 184 7 24 425 16 72 co c wo 6 6 o e ROO d d Ut e e e E O 0 x SIR Lee L In sar SOR i E c0 Kd 57 25 2 25 M 6060606606060606 5 5 C E 115 4 53 gt T Jr MT Ho cH Rls lan 5
5. 738 29 04 gt 547 21 54 4 40 1 58 4 558 21 97 EE EE pom N n D D n NJ 5 m0 u nunnne D n n DH n H H D o o alSN D H H el D H H Dp5pgpngpgnggb a H D o o 5 Qo ils Ir Lal CH S FRONT COLD AISLE Refrigerant discharge line Refrigerant liquid line Pressure relief valve discharge line Trough for communication cables Power connections Humidifier water supply 92006000 8 Condensate drain Dimensions are shown in mm in InRow RP Technical Data Manual 33 Air cooled Piping Access bottom view looking up 34 REAR HOT AISLE 479 18 86 345 13 58 57 25 2 25 6006960606060606 EN 115 4 53 s 141 5 54 176 6 91 E t E C a 1 FRONT COLD AISLE Pressure relief valve access 27 80 mm 1 09 in Refrigerant liquid line Refrigerant discharge line Condensate overflow 50 00 mm 1 97 in Communication connections 27 80 mm 1 09 in Power connections Condensate drain
6. e a sae 6 Height Adapters 6 Flex Hose Piping 6 Microprocessor Controller 7 Microprocessor Controller 7 Open Architect re Ves Eam ux xay e 7 Control Type asra ask rr gard RERBA TTE TAI UR 7 FUNCHONS ck REY x ear ta e RE 7 IM PRIIBRERPPPEPICTCC 7 Control sasa gera EE A eee A ae 7 DIM cM m 8 Chilled Water Only Alarms 8 Air cooled Only Alarms 8 InRow RP Technical Data Manual InRow RP Models 2 Chilled Water Interior Components front of unit 10 Air cooled Interior Components front of unit 12 Air cooled Interior Components back of unit 13 Chilled Water and Air cooled User Interface Connections 14 Chilled Water Electrical 15 Air cooled Electrical Panel 16 Performance Specifications 17 Chilled Water Performance Specifications 5 5 C 42 F EWT 17 Chilled Water Performance Specifications 7 2 C 45 F EWT 18 Chilled Water Performance Specifications 8 9 C 48 F EWT 19 Chilled Water Performance Specifications 10 C 50 F E
7. FLOW METER 1 Flow meter shall be factory piped inside the unit and connected to microprocessor controls to provide water flow rate through the unit The microprocessor controller shall also use this information to provide total unit capacity out of the unit while in operation 2 Flow meter shall be stainless steel construction turbine type meter compatible with glycol water solutions up to 5096 with accuracy of 1 596 or better on range 5 50 GPM CABLE WATER DETECTOR OPTIONAL 1 Theoptional leak detection sensing cable shall be shipped loose with the unit If water or other conductive liquids contact the cable anywhere along its length the main controller visually and audibly annunciates the leak 2 The optional detector shall be provided with a 6 1 m 20 ft of cable Cable may be cascaded up to 24 4 m 80 ft BRIDGE POWER CABLE TROUGH 1 Anoverhead power distribution bridge that sits between adjacent NetShelter racks and allows for removal of the unit without disrupting the overhead power cabling is available as an accessory 2 Cable trough shall be constructed of 1 5 mm 16 gauge cold rolled steel with a black powder coat finish BRIDGE DATA PARTITION 1 Anoverhead cable distribution that sits between adjacent Netshelter racks and allows for removal of the unit without disrupting overhead cabling is available as an accessory 2 Data partition shall be constructed of 1 5 mm 16 gauge cold rolled steel with a black
8. Humidifier water supply Dimensions are shown in mm in InRow RP Technical Data Manual Air Cooled Condensers Mechanical Data Sound Sound Air Quantity Fan Unit Connection Size Weight Capacity SKU Ambient Pr P Tem essure ressure Hot my MBH 1F P dbA dbA Vs CFM Qty KW Ga Liquid Kg Lbs pp kW 1C TD ACCD75201 95 35 67 62 4955 10500 1 22 13 8 1 1 3 8 in 163 360 8 8 4 6 ACCD75202 105 40 70 65 10383 22000 2 4 4 1 5 8 in 15 8 in 290 640 14 6 7 7 ACCD75203 115 46 72 68 14819 31400 3 6 6 21 8in 2 1 8 in 458 1010 25 8 13 6 ACCD75204 95 35 67 62 4955 10500 1 22 13 8 10 1 3 8 in 163 360 8 8 4 6 ACCD75205 105 40 70 65 10383 22000 2 4 4 15 8in 15 8 in 290 640 14 6 7 7 ACCD75206 115 46 72 68 14819 31400 3 6 6 2 1 8 in 2 1 8 in 458 1010 25 8 13 6 ACCD75207 95 35 54 51 5711 12100 1 2 2 42 mm 22 mm 173 381 17 6 9 3 ACCD75208 105 40 57 54 11940 25300 2 2 2 42mm 28 mm 307 677 27 1 14 3 ACCD75209 115 46 57 55 11374 24100 2 4 4 54 35 mm 360 792 48 2 254 at 10 ft and 100 Fan Speed at 10 ft and Max Compressor Speed Selected Ambient Temp Note Specifications given for conditions at sea level Electrical Data SKU Voltage FLA MCA MOP 208 230 7 0 15 0 25 ACCD75201 3 ph 60 Hz 208 230 14 0 20 0 35 ACCD75202 3
9. 12 15 2 52 000 15 2 52 000 1 00 0 6 10 0 11 3 7 7 7 14 13 1 45 000 13 1 45 000 1 00 0 5 7 6 6 2 1 8 8 16 11 1 38 000 11 1 38 000 1 00 0 4 5 8 4 1 4 10 18 9 3 32 000 9 3 32 000 1 00 0 3 4 5 3 0 9 11 1 20 7 7 26 000 7 7 26 000 1 00 0 2 3 5 2 0 5 29 4 C DB 18 1 C WB 85 F DB 64 5 F WB 5 5 10 23 8 81 000 23 8 81 000 1 00 1 1 17 7 31 10 4 6 6 12 21 1 72 000 21 1 72 000 1 00 0 8 13 2 18 6 01 7 7 14 18 5 63 000 18 5 63 000 1 00 0 6 10 1 11 3 7 8 8 16 16 1 55 000 16 1 55 000 1 00 0 5 7 9 7 2 3 32 2 C DB 18 9 C WB 90 F DB 66 1 F WB 5 5 10 31 5 108 000 31 5 108 000 1 00 1 4 22 8 51 17 1 6 6 12 28 3 97 000 28 3 97 000 1 00 1 1 17 2 30 9 9 35 0 C DB 19 8 C WB 95 F DB 67 7 F WB 5 5 10 40 6 139 000 40 6 139 000 1 00 1 8 28 7 80 26 8 Note All values are accurate to 5 and based on full speed with standard filters Note Reduce airflow and cooling capacity specifications by 7 for cooling units run at low input voltage 380 V Note Any CW flow rate of 0 19 l s 0 32 1 5 3 0 GPM 5 0 GPM may cause an increased error in flow rate and power calculation A fluid flow fault may result Any flow rate under 0 19 1 3 0 GPM may also display as 0 in the flow rate and power calculation Note For sustained operation a maximimum flow rate of 2 2 l s 34 GPM is recommended This may be exceeded by 25
10. 58 19 4 8 8 16 45 3 155 000 44 8 153 000 0 99 1 3 19 9 39 13 2 10 18 42 1 144 000 41 7 142 000 0 99 1 0 16 5 28 9 2 11 1 20 38 7 132 000 38 7 132 000 1 00 0 9 13 7 19 6 5 37 8 C DB 20 7 C WB 100 F DB 69 2 F WB 7 7 14 56 194 000 56 7 194 000 1 00 1 8 28 1 77 25 6 8 8 16 53 2 182 000 53 2 182 000 1 00 1 5 23 1 53 17 6 10 18 49 8 170 000 49 8 170 000 1 00 1 2 19 3 37 12 5 40 6 C DB 21 6 C WB 105 F DB 70 8 F WB 8 8 16 62 3 213 000 62 3 213 000 1 00 1 7 26 9 70 23 6 Note All values are accurate to 5 and based on full speed with standard filters Note Reduce airflow and cooling capacity specifications by 7 for cooling units run at low input voltage 380 V Note Any CW flow rate of 0 19 l s 0 32 1 6 3 0 GPM 5 0 GPM may cause an increased error in flow rate and power calculation A fluid flow fault may result Any flow rate under 0 19 1 3 0 GPM may also display as 0 in the flow rate and power calculation Note For sustained operation a maximimum flow rate of 2 2 l s 34 GPM is recommended This may be exceeded by 25 for peak conditions To convert feet of water to PSIG use the following formula ft H20 2 307 PSIG 20 InRow RP Technical Data Manual Chilled Water Performance Specifications 12 8 C 55 F EWT Total CW i
11. Low Watt Density Capacity kW BTU hr 6 20 500 Stages 2 FILTERS PLEATED STANDARD Quantity 3 Size mm in 418 x 470 16 45 x 18 5 Depth mm in 96 3 78 Efficiency 6 30 FILTERS PLEATED OPTIONAL Quantity 3 Size mm in 418 x 470 16 45 x 18 5 Depth mm in 96 3 78 Efficiency 6 85 PHYSICAL DATA Weight kg Ibs 378 833 Height mm in 199 78 40 Width mm in 600 23 62 Depth mm in 1070 42 13 CONNECTION SIZES Refrigerant Discharge 7 8 in ODF brazed Maximum pressure drop bar PSI 0 7 10 Liquid 7 8 ODF brazed Humidifier Supply Line mm in 6 35 1 4 Condensate Drain Drain Line mm in 12 7 1 2 Note Reduce airflow and cooling capacity specifications by 7 for cooling units run at low input voltage 380 V InRow RP Technical Data Manual 25 Sound Performance Data Chilled Water Tested Sound Data Fan Speed Airflow m s Sound Power dB at Frequency Hz re 10 2w Lp Sound Pressure dB SCFM re 20 microPa 125 250 500 1000 2000 4000 8000 dBA dBA 35 1 13 2500 69 5 37 5 63 5 60 0 54 0 47 5 40 0 65 4 54 9 50 1 79 3800 84 0 79 0 75 5 69 5 67 5 58 5 53 5 76 9 66 8 70 2 55 5400 92 0 87 0 83 5 79 0 74 5 69 5 63 5 85 9 75 0 85 3 04 6450 92 0 95 0 89 0 84 5 79 0 74 5 69 0 90 6 80 7 100 3 26 69
12. 000 32 5 111 000 0 94 0 9 13 8 19 6 5 11 1 20 31 8 109 000 29 9 102 000 0 94 0 7 11 5 14 4 6 29 49 DB 18 1 C WB 85 F DB 64 5 F WB 6 6 12 50 8 174 000 47 8 163 000 0 94 1 9 29 5 84 28 4 7 7 14 47 7 163 000 44 8 153 000 0 94 1 5 23 9 56 18 7 8 8 16 44 1 151 000 41 9 143 000 0 95 1 2 19 4 38 12 5 10 18 41 2 141 000 39 1 134 000 0 95 1 0 16 2 26 8 8 11 1 20 37 8 129 000 36 3 124 000 0 96 0 8 13 5 19 6 2 32 29 DB 18 9 C WB 90 F DB 66 1 F WB 7 7 14 54 5 186 000 52 3 179 000 0 96 1 7 27 1 71 23 8 8 8 16 51 4 175 000 49 3 168 000 0 96 1 4 22 4 49 16 6 10 18 47 8 163 000 46 3 158 000 0 97 1 2 18 6 35 11 6 11 1 20 44 8 153 000 43 4 148 000 0 97 1 0 15 7 25 8 32 35 0 C DB 19 8 C WB 95 F DB 67 7 F WB 7 7 14 62 0 212 000 60 2 205 000 0 97 1 9 30 6 90 30 3 8 8 16 58 8 201 000 57 0 195 000 0 97 1 6 25 4 63 21 3 10 18 55 6 190 000 53 9 184 000 0 97 1 4 21 4 45 15 2 11 1 20 52 4 179 000 50 9 174 000 0 97 1 2 18 3 33 11 1 37 8 C DB 20 7 WB 100 F DB 69 2 F WB 8 8 16 66 4 227 000 65 0 222 000 0 98 1 8 28 6 79 26 6 10 18 63 1 215 000 61 8 211 000 0 98 1 5 24 2 57 19 2 11 1 20 59 8 204 000 58 7 200 000 0 98 1 3 20 7 42 14 3 40 6 C DB 21 6 WB 105 F DB 70 8 F WB 10 18 71 4 244 000 70 0 239 000 0 98 1 7 27 3 72
13. 2 InRow 2 Scalable for High 2 Hot Aisle Containment System 3 Standard Features En Nana aaa Dada d Insulated Cabinet 4 Variable Speed Fans 4 Shutdown Input Alarm Output 4 Chilled Water Flow Meter 4 2 way 3 way Floating Point Valve CW 4 Counterflow Cooling Coil Condensate 4 Electric 2225 ga nee D reg NA oe GA LS 4 30 ASHRAE 52 1 4 Pipe Adapters CW only 4 Pipe Adapters Air Cooled 4 Selectable Top or Bottom Piping Connections 4 Dual Position Float Condensate Management 5 Network Management Card 5 Bay Kit InRow RP NetShelter SX 5 Remote Temperature Sensors 5 Humidifier niue IQ eau dq tke 5 Optional Features Cable Water Detector 6 Network Cable e EN NK ENN rk ha EIN ENN NNN EN 6 85 ASHRAE 52 1 6 PowerTrough E cde eee ee aaa a RA RR 6 Data Partition ics elc a AN E
14. 24 3 11 1 20 68 1 233 000 66 7 228 000 0 98 1 5 23 4 54 18 02 Note All values are accurate to 5 and based on full speed with standard filters Note Reduce airflow and cooling capacity specifications by 7 for cooling units run at low input voltage 380 V Note Any CW flow rate of 0 19 I s 0 32 1 5 3 0 GPM 5 0 GPM may cause an increased error in flow rate and power calculation A fluid flow fault may result Any flow rate under 0 19 1 5 3 0 GPM may also display as 0 in the flow rate and power calculation Note For sustained operation a maximimum flow rate of 2 2 l s 34 GPM is recommended This may be exceeded by 25 for peak conditions To convert feet of water to PSIG use the following formula ft H2O 2 307 PSIG InRow RP Technical Data Manual 17 Chilled Water Performance Specifications 7 2 C 45 F EWT Temperature dr 1 Total Net nsibl t nsible Heat Total CW DB wet bulb WB RACH T ie pose eod a Coa Pressure Drop C F kW BTU hr kW BTU hr SHR kPa ft H20 26 7 C DB 17 1 C WB 80 F DB 62 8 F WB 5 5 10 40 8 139 000 39 6 135 000 0 97 1 8 28 8 81 27 03 6 6 12 37 9 130 000 36 8 126 000 0 97 1 4 22 5 50 16 6 7 7 14 35 1 120 000 34 1 116 000 0 97 1 1 18 0 32 10 9 8 8 16 32 5 111 000 31 5 108 000 0 97 0 9 14 6 22
15. 56 0 191 000 1 00 1 5 24 3 58 19 4 10 18 52 6 180 000 52 6 180 000 1 00 1 3 20 4 41 13 9 11 1 20 49 4 169 000 49 4 169 000 1 00 1 1 17 3 30 9 9 40 6 C DB 21 6 C WB 105 F DB 70 8 F WB 7 7 14 68 6 234 000 68 6 234 000 1 00 2 1 33 7 109 36 5 8 8 16 64 9 222 000 64 9 222 000 1 00 1 8 28 0 76 25 4 10 18 61 3 209 000 61 3 209 000 1 00 1 5 23 5 54 18 2 Note All values are accurate to 5 and based on full speed with standard filters Note Reduce airflow and cooling capacity specifications by 7 for cooling units run at low input voltage 380 V Note Any CW flow rate of 0 19 I s 0 32 1 5 3 0 GPM 5 0 GPM may cause an increased error in flow rate and power calculation A fluid flow fault may result Any flow rate under 0 19 1 3 0 GPM may also display as 0 in the flow rate and power calculation Note For sustained operation a maximimum flow rate of 2 2 l s 34 GPM is recommended This may be exceeded by 25 for peak conditions To convert feet of water to PSIG use the following formula ft H20 2 307 PSIG InRow RP Technical Data Manual 19 Chilled Water Performance Specifications 10 C 50 F EWT Temperature dry bulb DB wet bulb CW Delta T Cade BE ae CW Flow Rate e S CF kw BTU hr k
16. InRow RP protocol is open for integration with all building management systems Communication interface on the system can be MODBUS RS485 or Ethernet Control Type Controller utilizes proportional integral derivative PID a time proven precision environmental control method This allows for custom tuning of control variables to achieve desired system response Functions Supply and Return Air Conditions Operational Mode Control Event Logging Alarms Redundant Group Control FanSpeed Adjustment Input Output Module Programming InRow RP Technical Data Manual Critical Alarm LED Warning Alarm LED Check Log LED Status LED Liquid Crystal Display LCD Menu Selection scroll keys Escape key Enter key GEHALT Help key Logging The event log keeps a record of all alarms and events Each event log contains a time date stamp as well as operating conditions at the time of occurrence The controller also displays run time in hours for major components air filters fans and condensate pump as well as humidifier heater and compressor for the air cooled unit Control The backlit four line by twenty character display is password configurable Alarms The microprocessor controller shall activate a visible and audible alarm in the following occurrences CoolFail Rack inlet temperature violation Rack inlet temperature sensor fault Air filter c
17. The unit shall be equipped with an automatic transfer switch ATS The ATS shall automatically switch from a main power supply to a secondary power supply in the event of a power outage without change in equipment operation The ATS shall monitor the main power supply so that when the power is restored to the primary source it will automatically switch from the secondary source back to the main power source MAIN DISCONNECT SWITCH 1 Unit shall be provided with Thermal Magnetic circuit breakers with interrupt capacity ratings per UL489 CSA C22 2 IEC 947 Voltage kAIC 200 240V 50 60Hz 50 380 415V 50Hz 36 460 480V 60Hz 22 2 Chilled Water Units shall include main disconnect switches located on the E panel in order to individually disconnect dual A B power inputs 3 Air cooled Units shall include a main disconnect switch located on the E panel in order to disconnect power input 4 Acondenser disconnect shall be field supplied MICROPROCESSOR CONTROLLER 1 Monitoring and Configuration The display shall allow monitoring and configuration of the air conditioning unit through a menu based control Functions include status reporting set up and temperature set points Four LEDs report the operational status of the connected air conditioning unit 2 Controls The microprocessor controller shall come equipped with control keys to allow the user to navigate between menus select items and input alpha numeric informat
18. accuracy shall be within 1 degree F accuracy Remote Temperature Sensors Three remote rack inlet temperature sensors shall be shipped with the unit to provide control input based on rack inlet temperature Internal Humidity Sensors Humidity sensors shall be mounted behind both the front and rear doors and shall provide control input based on humidity in supply air Humidifier sensor shall be 3 RH accuracy full scale Water Temperature Sensors Internal supply and return chilled water temperature sensors shall be installed into sealed wells Wells are filled with thermal conducting heat transfer grease to provide accurate temperature sensors SELECTABLE TOP OR BOTTOM PIPING CHILLED WATER ONLY l Pipe connections The unit equipped with field connection from either the top or bottom of the unit Unit connections shall be made internal to the unit Pipe adapter The unit shall include two pipe adapters that convert a 31 75 mm 1 1 4 in NPT to a 31 75 mm 1 1 4 in BSPT manufactured in accordance with BS21 Pipe adapters shall ship loose with the unit for field installation where applicable InRow RP Technical Data Manual SELECTABLE TOP OR BOTTOM PIPING AIR COOLED ONLY 1 Pipeconnections The unit is equipped with field connection from either top or bottom of the unit Unit connections shall be made internal to the unit 2 Pipe adapters The unit shall include 1 in Rotolock to sweat adapters and associated Teflon seals
19. for peak conditions To convert feet of water to PSIG use the following formula ft H20 2 307 PSIG 22 InRow RP Technical Data Manual Chilled Water Data General MODEL ACRP 500 Series MODULATING VALVES Size 3 Way Ball Valve NPT mm in 25 4 1 AIR SYSTEM FANS Standard Filter Installed Air Volume 1 8 SCFM 3162 6700 Fan Motor W HP 1100 1 5 Number of Fans 3 COOLING COIL COPPER TUBE ALUMINUM FIN Face Area m ft 0 74 7 9 Rows Deep 4 Fins per meter Fins per inch 468 12 HUMIDIFICATION SOLID STATE ELECTRODE CANISTER Flush Cycle Automatic Capacity kg hr Ibs hr 3 0 6 6 kW 2 25 REHEAT Electric Equally Loaded Three Stage Finned Tubular Low Watt Density Capacity kW BTU hr 9 0 30 700 Stages 3 FILTERS PLEATED STANDARD Quantity 4 Size mm in 418 x 470 16 45 x 18 5 Depth mm in 96 3 78 Efficiency 6 30 FILTERS PLEATED OPTIONAL Quantity 4 Size mm in 418 x 470 16 45 x 18 5 Depth mm in 96 3 78 Efficiency Yo 85 PHYSICAL DATA Weight kg Ibs 352 776 Height mm in 199 78 40 Width mm in 600 23 62 Depth mm in 1070 42 13 CONNECTION SIZES Chilled Water Supply Line mm in 35 0 1 3 8 Return Line mm in 35 0 1 3 8 Humidifier Supply Line mm in 6 35 1 4
20. i Pressure tn uuu ype cuiua D C F kW BTU hr kW BTU hr SHR kPa ft H20 26 7 C DB 17 1 WB 80 F DB 62 8 F WB 5 5 10 24 7 85 000 24 7 85 000 1 00 1 2 18 3 33 11 3 6 6 12 22 3 76 000 22 3 76 000 1 00 0 9 13 9 20 6 7 7 7 14 20 0 68 000 20 0 68 000 1 00 0 7 10 8 12 4 2 8 8 16 17 8 61 000 17 8 61 000 1 00 0 5 8 6 8 2 8 10 18 15 8 54 000 15 8 54 000 1 00 0 4 6 9 5 1 8 11 1 20 13 9 48 000 13 9 48 000 1 00 0 4 5 6 4 1 2 29 4 DB 18 1 WB 85 DB 64 5 WB 5 5 10 31 3 107 000 31 3 107 000 1 00 1 4 22 6 50 16 9 6 6 12 28 5 97 000 28 5 97 000 1 00 1 1 17 3 30 10 2 7 7 14 25 8 88 000 25 8 88 000 1 00 0 9 13 6 19 6 5 8 8 16 23 3 80 000 23 3 80 000 1 00 0 7 10 8 8 4 2 10 18 21 0 72 000 21 0 72 000 1 00 0 6 8 8 8 2 8 11 1 20 18 7 64 000 18 7 64 000 1 00 0 5 7 2 6 1 8 32 2 DB 18 9 WB 90 DB 66 1 WB 5 5 10 39 1 133 000 39 1 133 000 1 00 1 7 27 7 75 24 9 6 6 12 35 9 123 000 35 9 123 000 1 00 1 3 21 3 45 15 02 7 7 14 32 8 112 000 32 8 112 000 1 00 1 1 16 9 29 9 7 8 8 16 30 0 102 000 30 0 102 000 1 00 0 9 13 6 19 6 5 10 18 27 2 93 000 27 2 93 000 1 00 0 7 11 1 13 4 4 35 0 C DB 19 8 WB 95 F DB 67 7 F WB 6 6 12 44 2 151 000 44 2 151 000 1 00 1 6 25 9 66 21 9 7 7 14 40 8 139 000 40
21. ph 60 Hz 208 230 21 0 22 8 40 ACCD75203 3 ph 60 Hz 460 3 5 15 0 15 ACCD75204 3 ph 60 Hz 460 ACCD75205 3 ph 60 Hz 7 0 15 0 15 460 ACCD75206 3 ph 60 Hz 10 5 15 0 20 ACCD75207 00 99 3 ph 50 Hz ACCD75208 i 74 3 ph 50 Hz ACCD75209 100 74 N A N A 3 ph 50 Hz FLA Full Load Amps MCA Minimum Circuit Amperes Maximum Overcurrent Protection InRow RP Technical Data Manual ACCD75201 and ACCD75204 4248 49 13 514 0029 1 zeg gt Dimensions are shown in mm in Note All condensers shown on this page have eight 22 mm 0 875 in mounting holes on their lower rails 36 InRow RP Technical Data Manual ACCD75207 Dimensions are shown in mm in All condensers shown on this page have 16 mm 0 63 in mounting holes on each of their lower legs Air cooled Condenser Features Available in one to three fan configurations APC offers air cooled condensers with a vertical air discharge pattern These condensers utilize variable speed EC motor technology for improved sound and energy performance 60 Hz specific features Constructed with aluminum housing Weatherproof control panel with a factory mounted door interrupt disconnect switch 50 Hz specific features Constructed with painted galvanized steel Note A disconnect should be field supplied based on MOP numbers InRow RP Technical Data Manual 37 38 Guide Specifications PART 1 GEN
22. powder coat finish COOLING FLUIDS Chilled Water and solutions of propylene or ethylene glycol up to 50 may be used Solutions of brine or other aqueous salt are NOT permitted FREEZE PROTECTION Per ASHRAE Handbook Fundamentals 2001 21 5 a maximum of 30 ethylene glycol and 3596 propylene glycol are needed for freeze protection Please consult ASHRAE handbook for more details InRow RP Technical Data Manual 43 Guidelines for Installation The InRow RP provides reliable accurate temperature control of computer rooms laboratories and other environments that require close tolerance control The unit incorporates the latest system design innovations to provide you with optimum efficiency reliability and accuracy of control The InRow RP unit will provide years of trouble free service when installed and maintained by technically qualified personnel For more detailed information see the InRow RP Installation manual 990 2696 air cooled and 990 2710 chilled water Room preparation During the design of the room consideration should be given to the following factors ease of entry for the system floor loading factors and accessibility of piping and wiring The room must be sealed with a vapor barrier to minimize moisture infiltration Polyethylene film plastic sheeting is a good vapor barrier for ceiling and wall applications Rubber or plastic based paints should be applied to concrete floors and walls The room should
23. 00 90 0 96 5 90 5 85 0 80 5 76 0 70 5 91 7 81 9 Weighted Sound Pressure dBA in a 232 2 m 8200 f room at 6 ft 1 8 m distance Air cooled Tested Sound Data Fan Speed Airflow m s Sound Power dB at Frequency Hz re 1012W Lp Sound SCFM Pressure dB re 20 microPa 125 250 500 1000 2000 4000 8000 dBA dBA 50 1 27 2700 84 5 87 5 78 0 71 5 75 0 66 5 65 5 83 4 72 8 75 1 79 3800 92 5 90 0 84 0 81 5 TUS 71 5 68 5 87 6 76 8 100 2 26 4800 90 0 98 0 91 0 85 0 81 0 76 5 72 0 92 3 82 8 Weighted Sound Pressure dBA in a 8200 f 232 2 m room at 6 ft 1 8 m distance Based on compressor operating at full speed Electrical Data SKU Voltage MCA MOP LRA RLA FLA Hz Power kW ACRP100 200 240 80 1 100 160 50 0 N A 50 60 19 ACRP101 460 480 39 9 50 139 23 2 N A 60 21 ACRP102 380 415 N A N A 139 23 2 32 50 60 20 500 200 240 46 8 50 N A N A N A 50 60 14 501 460 480 24 8 30 60 14 502 380 415 N A N A N A 24 50 60 15 Note Above data is based on maximum operating condition Local or national codes may require the installation of an external disconnect The disconnect must be rated properly for the equipment Local or national codes may require the installation of external disconnects Two disconnects would be required and must be rated properly for the equipment MCA Minimum Circuit Ampacity MOP Maximum Overcurrent Protection LRA Locked Rotor Amps RL
24. 05 F DB 70 8 F WB 8 8 16 69 6 238 000 69 6 238 000 1 00 1 9 29 9 86 28 9 10 18 66 1 226 000 66 1 226 000 1 00 1 6 25 3 63 21 02 11 1 20 62 7 214 000 62 7 214 000 1 00 1 4 21 7 46 15 5 Note All values are accurate to 5 and based on full speed with standard filters Note Reduce airflow and cooling capacity specifications by 7 for cooling units run at low input voltage 380 V Note Any CW flow rate of 0 19 l s 0 32 1 5 3 0 GPM 5 0 GPM may cause an increased error in flow rate and power calculation A fluid flow fault may result Any flow rate under 0 19 1 5 3 0 GPM may also display as 0 in the flow rate and power calculation Note For sustained operation a maximimum flow rate of 2 2 l s 34 GPM is recommended This may be exceeded by 25 for peak conditions To convert feet of water to PSIG use the following formula ft H20 2 307 PSIG 18 InRow RP Technical Data Manual Chilled Water Performance Specifications 8 9 C 48 F EWT i i Total CW Pressure Ee C F kW BTU hr kW BTU hr SHR kPa ft H20 26 7 C DB 17 19 WB 80 F DB 62 8 F WB 5 5 10 35 7 122 000 34 6 118 000 0 97 1 6 25 5 63 21 3 6 6 12 32 9 112 000 31 9 109 000 0 97 1 2 19 7 39 12 9 7 7 14 30 3 103 000 29 4 100 000 0 97
25. 1 0 15 7 25 8 3 8 8 16 27 7 95 000 26 9 92 000 0 97 0 8 12 7 17 5 5 10 18 25 3 86 000 24 5 84 000 0 97 0 7 10 4 11 3 9 11 1 20 22 7 78 000 22 3 76 000 0 98 0 5 8 5 8 2 5 29 49 DB 18 19 WB 85 F DB 64 5 F WB 5 5 10 42 3 145 000 41 5 142 000 0 98 1 9 29 9 86 28 9 6 6 12 39 4 134 000 38 6 132 000 0 98 1 5 23 3 53 17 8 7 7 14 36 5 125 000 35 8 122 000 0 98 1 2 18 6 35 11 6 8 8 16 33 7 115 000 33 1 113 000 0 98 1 0 15 1 23 7 9 10 18 31 1 106 000 30 4 104 000 0 98 0 8 12 5 16 5 3 11 1 20 28 5 97 000 27 9 95 000 0 98 0 7 10 4 12 3 9 32 2 C DB 18 9 C WB 90 F DB 66 1 F WB 6 6 12 47 0 161 000 46 1 157 000 0 98 1 7 27 5 73 24 5 7 7 14 43 9 150 000 43 0 147 000 0 98 1 4 22 1 48 16 2 8 8 16 40 9 140 000 40 1 137 000 0 98 1 1 18 1 33 10 9 10 18 37 6 128 000 37 2 127 000 0 99 0 9 14 9 23 7 6 11 1 20 34 8 119 000 34 4 118 000 0 99 0 8 12 5 16 5 3 35 0 C DB 19 8 C WB 95 F DB 67 7 F WB 7 7 14 51 4 176 000 50 9 174 000 0 99 1 6 25 6 64 21 5 8 8 16 48 2 165 000 47 7 163 000 0 99 1 3 21 1 44 14 8 10 18 45 0 154 000 44 6 152 000 0 99 1 1 17 6 31 10 4 11 1 20 42 0 143 000 41 6 142 000 0 99 0 9 14 8 22 7 6 37 8 C DB 20 7 C WB 100 F DB 69 2 F WB 7 7 14 60 0 205 000 59 4 203 000 0 99 1 9 29 7 85 28 6 8 8 16 56 0 191 000
26. 30 5 104 000 Sensible kW BTU hr 30 5 104 000 35 0 C DB 19 9 C WB 95 F DB 67 8 F WB Total kW BTU hr 33 7 115 000 Sensible kW BTU hr 33 7 115 000 37 8 C DB 20 7 C WB 100 F DB 69 3 F WB Total kW BTU hr 36 9 126 000 Sensible kW BTU hr 36 9 126 000 40 6 C DB 21 6 C WB 105 F DB 70 8 F WB Total kW BTU hr 36 6 125 000 Sensible kW BTU hr 36 6 125 000 Airflow reduced to 4000 SCFM at this condition to maintain adequate return gas temperature Note Unit is not recommended for use with total loads of 10 kW or less Note Shaded lines represent leaving air temperatures above ASHRAE specifications of 25 C 77 F at maximum airflow Note Reduce airflow and cooling capacity specifications by 7 for cooling units run at low input voltage 380 V 24 InRow RP Technical Data Manual Air cooled Data General MODEL ACRP 100 Series AIR SYSTEM FAN Standard Filter Installed Air Volume I s SCFM 2265 4800 Fan Motor W HP 1100 1 5 Number of Fans 2 COOLING COIL COPPER TUBE ALUMINUM FIN Face Area m ft 56 6 0 Rows Deep 4 HUMIDIFICATION SOLID STATE ELECTRODE CANISTER Flush Cycle automatic Capacity kg hr Ibs hr 3 6 6 kW 2 25 Electric Equally Loaded Two Stage Finned Tubular
27. 7 4 10 18 29 8 102 000 28 9 99 000 0 97 0 8 12 0 15 5 1 11 1 20 27 3 93 000 26 5 90 000 0 97 0 6 10 0 3 7 29 4 C DB 18 1 C WB 85 F DB 64 5 F WB 6 6 12 45 0 154 000 43 7 149 000 0 97 1 7 26 4 68 22 6 77 14 42 0 144 000 40 8 139 000 0 97 1 3 21 2 44 14 8 8 8 16 39 1 134 000 38 0 130 000 0 97 1 1 17 4 30 10 2 10 18 36 3 124 000 35 2 120 000 0 97 0 9 14 4 21 7 2 11 1 20 33 3 114 000 32 6 111 000 0 98 0 8 11 9 15 5 1 32 2 C DB 18 9 C WB 90 F DB 66 1 F WB 6 6 12 52 3 179 000 51 2 175 000 0 98 1 9 30 4 89 29 8 7 7 14 49 2 168 000 48 2 165 000 0 98 1 5 24 5 59 19 9 8 8 16 46 1 157 000 45 2 154 000 0 98 1 3 20 2 41 13 6 10 18 42 7 146 000 42 3 144 000 0 99 1 1 16 7 28 9 5 11 1 20 39 8 136 000 39 4 135 000 0 99 0 9 14 1 20 6 9 35 0 C DB 19 8 C WB 95 F DB 67 7 F WB 77 14 57 2 195 000 56 0 191 000 0 98 1 8 28 3 78 26 1 8 8 16 53 4 182 000 52 9 181 000 0 99 1 5 23 2 53 17 8 10 18 50 3 172 000 49 8 170 000 0 99 1 2 19 5 38 12 7 11 1 20 47 2 161 000 46 7 160 000 0 99 1 0 16 5 28 9 2 37 8 C DB 20 7 C WB 100 F DB 69 2 F WB 8 8 16 61 6 210 000 61 0 208 000 0 99 1 7 26 6 69 23 1 10 18 58 3 199 000 57 7 197 000 0 99 1 4 22 4 50 16 6 11 1 20 55 1 188 000 54 5 186 000 0 99 1 2 19 1 36 12 2 40 6 C DB 21 6 C WB 1
28. 77 879 61 912 70 947 66 983 86 1021 32 1061 28 1103 10 1146 80 1193 00 1241 69 f3 Ib 13 58 14 09 14 62 15 18 15 76 16 36 17 00 17 67 18 37 19 11 19 89 Density g m Ib fC 1185 37 1137 31 1089 26 1057 22 1009 16 97713 94510 913 05 865 00 832 97 800 92 0 074 0 071 0 068 0 066 0 063 0 061 0 059 0 057 0 054 0 052 0 050 Density Ratio 1 000 0964 0929 0 895 0 862 0 830 0 799 0 769 0 739 0711 0 683 Capacity Correction 1 000 0 981 0 962 0933 0 913 0 884 0 865 0 846 0 826 0 807 0 787 Density ratio is used for air flow correction factor Capacity correction is used for performance derate Air cooled Performance Specifications NET COOLING CAPACITY Entering Air Temperature ACRP 100 Series 22 2 C DB 15 5 C WB 72 F DB 60 F WB Total kW BTU hr 22 8 78 000 Sensible kW BTU hr 19 0 65 000 23 9 C DB 16 2 C WB 75 F DB 61 1 F WB Total kW BTU hr 25 2 86 000 Sensible kW BTU hr 21 7 74 000 26 7 C DB 17 1 C WB 80 F DB 62 8 F WB Total kW BTU hr 26 9 92 000 Sensible kW BTU hr 26 9 92 000 29 4 C DB 18 1 C WB 85 F DB 64 6 F WB Total kW BTU hr 29 0 99 000 Sensible kW BTU hr 29 0 99 000 32 2 C DB 19 0 C WB 90 F DB 66 2 F WB Total kW BTU hr
29. 8 139 000 1 00 1 3 20 6 42 14 1 8 8 16 37 5 128 000 37 5 128 000 1 00 1 1 16 7 28 9 5 37 8 C DB 20 7 C WB 100 F DB 69 2 F WB 7 7 14 49 8 170 000 49 8 170 000 1 00 1 6 24 8 60 20 1 40 6 C DB 21 6 C WB 105 F DB 70 8 F WB 7 7 14 59 7 204 000 59 7 204 000 1 00 1 9 29 5 84 28 2 Note All values are accurate to 5 and based on full speed with standard filters Note Reduce airflow and cooling capacity specifications by 7 for cooling units run at low input voltage 380 V Note Any CW flow rate of 0 19 1 5 0 32 1 5 3 0 GPM 5 0 GPM may cause an increased error in flow rate and power calculation A fluid flow fault may result Any flow rate under 0 19 1 3 0 GPM may also display as 0 in the flow rate and power calculation Note For sustained operation a maximimum flow rate of 2 2 1 5 34 GPM is recommended This may be exceeded by 25 for peak conditions To convert feet of water to PSIG use the following formula ft H20 2 307 PSIG InRow RP Technical Data Manual 21 Chilled Water Performance Specifications 15 5 60 F EWT Total CW ng ewet ie Cw raw Rate Pressure kW BTU hr kW BTU hr SHR kPa ft H20 26 7 C DB 17 1 WB 80 F DB 62 8 F WB 5 5 10 17 5 60 000 17 5 60 000 1 00 0 9 13 5 19 6 2 6 6
30. A Rated Load Amps FLA Full Loa 26 d Amps InRow RP Technical Data Manual Dimensional Data InRow RP Assembled Module 029 1994 78 39 9 5 SCH na2465a Dimensions are shown in mm in InRow RP Technical Data Manual 27 SX to VX Height Adapter SX to 48U SX Height Adapter na2445a 28 Dimensions are shown in mm in InRow RP Technical Data Manual na2446a Piping and Mechanical Connections Chilled Water Piping Diagram InRow InRow Bottom piping RP RP Return Suppl Top piping Return InRow InRow RP RP Flex hose or copper Circuit setter field installed Copper tubing Pry Hose end drain with cap Y strainer with 20 mesh screen field CX Isolation valve installed Blow down may be installed on Y strainer InRow RP Technical Data Manual 29 Top Chilled Water Piping Access top view Note Top or bottom entry can be chosen individually for each type of connection i e power condensate drain humidifier water supply chilled water supply and chilled water return Top piping configuration will have the same valves and strainers as bottom piping configuration REAR HOT AISLE 1 58 2 32 59 2 32 554 21 81 554 21 81 40 59 105 4 12 1 58 p d H 73 2 86 v 737 29 02 9 635 24 99 gt
31. AMAGES FOR LOSS OF BUSINESS CONTRACT REVENUE DATA INFORMATION OR BUSINESS INTERRUPTION RESULT ING FROM ARISING OUT OR IN CONNECTION WITH THE USE OF OR INABILITY TO USE THIS PUBLICATION OR THE CONTENT EVEN IF AMERI CAN POWER CONVERSION CORPORATION HAS BEEN EXPRESSLY ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AMERICAN POWER CONVERSION CORPORATION RESERVES THE RIGHT TO MAKE CHANGES OR UPDATES WITH RESPECT TO OR IN THE CONTENT OF THE PUBLICATION OR THE FORMAT THEREOF AT ANY TIME WITHOUT NOTICE Copyright intellectual and all other proprietary rights in the content including but not lim ited to software audio video text and photographs rests with American Power Conversion Corporation or its licensors All rights in the content not expressly granted herein are reserved No rights of any kind are licensed or assigned or shall otherwise pass to persons accessing this information This Publication shall not be for resale in whole or in part Contents OVOFVIOW EEN Capacity tue Stk aaa Ee Re E Rr E EUER eek a ana ASS 1 Room Air Distribution 1 Configuration Ae Ka D E yx c a EEN a a 1 Compliance 1 Chilled Water Standard Features 1 Air cooled Standard Features 1 EE 1 Scalable Solution for Critical Environments
32. APC by Schneider Electric InRow RP Chilled Water Direct Expansion 50 60 Hz AIR COOLED ACRP100 ACRP101 ACRP102 CHILLED WATER ACRP500 ACRP501 ACRP502 Technical Data American Power Conversion Legal Disclaimer The information presented in this manual is not warranted by the American Power Conversion Corporation to be authoritative error free or complete This publication is not meant to be a substitute for a detailed operational and site specific development plan Therefore American Power Conversion Corporation assumes no liability for damages violations of codes improper installation system failures or any other problems that could arise based on the use of this Publication The information contained in this Publication is provided as is and has been prepared solely for the purpose of evaluating data center design and construction This Publication has been compiled in good faith by American Power Conversion Corporation However no representa tion is made or warranty given either express or implied as to the completeness or accuracy of the information this Publication contains IN NO EVENT SHALL AMERICAN POWER CONVERSION CORPORATION OR ANY PARENT AFFILIATE OR SUBSIDIARY COMPANY OF AMERICAN POWER CONVERSION CORPORATION OR THEIR RESPECTIVE OFFICERS DIREC TORS OR EMPLOYEES BE LIABLE FOR ANY DIRECT INDIRECT CONSE QUENTIAL PUNITIVE SPECIAL OR INCIDENTAL DAMAGES INCLUDING WITHOUT LIMITATION D
33. Condensate Drain Drain Line mm in 12 7 1 2 For sustained operation a maximimum flow rate of 2 2 l s 34 GPM is recommended This may be exceeded by 25 for peak conditions Maximum working pressure for the unit is 300 psig 2068 4 kPa Note Reduce airflow and cooling capacity specifications by 7 for cooling units run at low input voltage 380 V InRow RP Technical Data Manual 23 Glycol Correction Factors Performance Criteria Glycol Solution Percent Weight of Solution 0 1096 20 30 40 50 Capacity Ethylene 1 00 0 97 0 93 0 88 0 81 0 75 Propylene 1 00 0 96 0 90 0 82 0 77 0 74 Pressure Drop Ethylene 1 00 1 04 1 13 1 21 1 31 1 41 Propylene 1 00 1 09 1 20 1 35 1 52 1 67 All correction factors are based on unit entering conditions of 29 4 C 85 F DB 18 1 C 64 5 F WB 1368 6 L S 6950 CFM 1 72 L S 27 3 GPM and 7 2 C 45 F EFT Multiply capacity of device or system by factor above for solution Multiply pressure drop of system by factor above for solution Glycol concentrations over 50 are not recommended Altitude Correction Factors for InRow Products Room Condition 72 DB 50 RH Altitude m ft 0 305 610 915 1219 1524 1829 2134 2438 2743 3048 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Specific volume cm g 847
34. ERAL 1 01 1 02 1 03 SUMMARY A The environmental control system shall be designed specifically for precision temperature and humidity control applications It will automatically monitor and control heating cooling humidifying dehumidifying and filtering functions for the conditioned space The system shall be built to the highest quality engineering and manufacturing standards and shall be floor mounted and configured for horizontal airflow with draw through air pattern to provide uniform air distribution over the entire face of the coil DESIGN REQUIREMENTS A The system shall be as described in the following specification as manufactured by APC 1 Model 4 2 Total net cooling capacity kW MBH 3 Sensible net cooling capacity kW MBH 4 Return air dry bulb temperature C F DB 5 Return air wet bulb temperature C F WB 6 Humidity RH 7 Air Volume L s CFM 8 Humidifier capacity kg hr Ibs hr 9 Electrical supply V Hz SUBMITTALS A Submittals shall be provided with the proposal and shall include capacity data electrical data physical data electrical connection drawing and piping connection drawing QUALITY ASSURANCE A The system shall be factory tested prior to shipment Testing shall include but not be limited to complete pressure and leak testing to ensure system integrity Hi Pot test and controls calibration and settings The system shall be NR
35. TL listed MCA and electrical system shall be UL Listed to UL 1995 and CSA 22 2 No 236 WARRANTY A System parts shall be warranted for a period of 18 months from date of shipment and 12 months from startup PART 2 PRODUCT 2 01 STANDARD COMPONENTS A CABINET CONSTRUCTION l Exterior panels shall be 1 2 mm 18 gauge steel Front and rear exterior panels shall be 1 2 mm 18 gauge perforated steel with 69 5 open free area and equipped with a keyed lock to provide a means of securing access to the internal components of the unit The frame shall be constructed of 1 5 mm 16 gauge formed steel welded for maximum strength All units shall provide maintenance from the front and rear allowing units to be placed within a row of racks All exterior panels and frame shall be powder coated for durability and attractive finish Exterior frame and panel color shall have color values L 74 50 a 53 b 48 20 Units shall include casters and leveling feet to allow ease of installation in the row and provide a means to level the equipment with adjacent IT racks InRow RP Technical Data Manual VARIABLE SPEED FAN ASSEMBLY 1 Variable Speed Fans The unit is equipped with variable speed electronically commutated 400 mm backward incline fans complete with Inlet Volute 2 Fan Protection discharge finger guard Outlet of the fan should include a cage type finger guard AUTOMATIC TRANSFER SWITCH CHILLED WATER ONLY
36. W BTU hr SHR S GPM kPa ft H50 26 7 C DB 17 1 C WB 80 F DB 62 8 F WB 5 5 10 32 6 111 000 31 8 109 000 0 98 1 5 23 5 54 18 02 6 612 29 9 102 000 29 2 100 000 0 98 1 1 18 1 33 11 1 7 7 14 27 4 93 000 26 7 91 000 0 98 0 9 14 3 21 6 9 8 8 16 24 9 85 000 24 3 83 000 0 98 0 7 11 5 14 4 6 10 18 22 6 77 000 22 0 75 000 0 98 0 6 9 4 10 3 2 11 1 20 20 4 70 000 19 9 68 000 0 98 0 5 7 7 VER 29 4 C DB 18 1 C WB 85 F DB 64 5 F WB 5 5 10 39 6 135 000 38 6 132 000 0 98 1 8 28 0 76 25 6 6 6 12 36 6 125 000 35 7 122 000 0 98 21 8 47 15 7 7 714 33 8 115 000 32 9 112 000 0 98 1 1 17 3 30 10 2 8 8 16 31 1 106 000 30 3 103 000 0 98 0 9 14 0 20 6 7 10 18 28 5 97 000 27 7 95 000 0 98 0 7 11 5 14 4 6 11 1 20 26 0 89 000 25 3 86 000 0 98 0 6 9 5 10 3 2 32 2 C DB 18 9 C WB 90 F DB 66 1 F WB 6 6 12 43 6 149 000 43 2 147 000 0 99 1 6 25 6 64 21 5 7 7 14 40 5 138 000 40 1 137 000 0 99 1 3 20 5 42 13 9 8 8 16 37 6 128 000 37 2 127 000 0 99 1 1 16 7 28 9 5 10 18 347 119 000 34 4 117 000 0 99 0 9 13 8 20 6 5 11 1 20 32 0 109 000 31 7 108 000 0 99 0 7 11 5 14 4 6 35 0 C DB 19 8 C WB 95 F DB 67 7 F WB 6 6 12 51 9 177 000 51 4 175 000 0 99 1 9 30 1 88 29 3 7 7 14 48 5 166 000 48 0 164 000 0 99 1 5 24 2
37. WT 20 Chilled Water Performance Specifications 12 8 C 55 F EWT 21 21 Chilled Water Performance Specifications 15 5 C 60 F EWT 22 Chilled Water Data 23 Glycol Correction Factors 24 Altitude Correction Factors for InRow Products 24 Air cooled Performance Specifications 24 Air cooled Data General 25 Sound Performance Data 26 El ctrical Data 5 3 mulam xx v A E 26 Dimensional Data 27 InRow RP Assembled 27 SX to VX Height 28 SX to 480 SX Height Adapter 28 Piping and Mechanical Connections 29 Chilled Water Piping Diagram 29 Top Chilled WaterPiping Access top view 30 Air cooled Piping Diagram 32 Air cooled Piping Access 33 Air Cooled Condensers 35 Mechanical Data saa as ma wand a Ae SN Us 35 Electrical Datar ev ate eee SN a a 35 ACCD75201 and ACCD75204 36 ACCD75202 ACCD75205 36 ACCD75203 ACCD75206
38. al Data Manual Humidifier The humidifier is a self contained steam generating type factory piped and wired with a disposable cylinder and an automatic solid state control circuit Humidifier canisters are replaceable The humidifier controller communicates directly to the microprocessor controller and provides complete status and control at the operator interface Optional Features Cable Water Detector A leak detection cable is placed on the floor or subfloor around all possible leak sources If water or other conductive liquids contact the cable anywhere along its length the microprocessor controller announces the leak visually audibly and across the network The 6 1 m 20 ft cable may be cascaded to make custom lengths up to 24 4 m 80 ft Network Cable Various lengths of network cable are available to ship with your cooling system The network cable is used to interconnect multiple cooling units in a redundant group as well as to connect the network management card to your LAN 85 ASHRAE 52 1 Filter Electrical equipment requires clean particle free air thus making the filtration of the air extremely important Optionally the system uses a 85 efficient 100 mm 4 in deep loading pleated filter Deeper filters produce a lower pressure drop requiring less energy during normal operation The 100 synthetic media will not absorb moisture and is resistant to most common chemicals The filter is moistu
39. alve actuator fault Fluid flow fault Entering fluid temperature high violation Entering fluid temperature sensor fault Leaving fluid temperature sensor fault Power source failure Fluid calibration High discharge pressure Low suction pressure High suction pressure Compressor drive failure Compressor drive warning Compressor run hours violation Compressor drive RS485 communication fault Excessive compressor cycling InRow RP Technical Data Manual ba Air flow decreased while compressor off bb Suction pressure sensor failure bc Discharge pressure sensor failure bd High pressure switch active be Fan speed decreased to avoid high pressure event only bf Compressor speed decreased to avoid high pressure event only bg Compressor high pressure bh Oil return pump active Logging The microprocessor controller shall log and display all available events Each alarm log shall contain time date stamp as well as operating conditions at the time of occurrence Controller shall display the run time hours for major components NETWORK MANAGEMENT CARD The unit shall include a network management card to provide management through a computer network through TCP IP Management through the network should include the ability to change set points as well as view and clear alarms COOLING COIL AND CONDENSATE PAN 1 Chilled Water Cooling coil shall use raised lance type corrugated aluminum fin and 12 7 mm 1 2 in OD copper tu
40. and rear exterior panel are constructed of 1 2 mm 18 gauge perforated steel with 69 596 open free area Insulation 1s 80 1 kg m 5 lb ft density and complies with ASTM E84 rating of 25 50 All panels include a key latch for safety and security for easy access and removal Variable Speed Fans The InRow RP unit is equipped with variable speed electrically commutated 400 mm 15 8 in backward incline direct drive fans The chilled water unit is equipped with three fans while the air cooled unit has two In order to provide uniform airflow over the cooling coil the fans provide a draw through air pattern Fans are easily serviced in the field Shutdown Input Alarm Output The unit provides one field connection input for remote shutdown and one field connection alarm output Chilled Water Flow Meter Internal piping of the unit includes a flow meter wired into the microprocessor controller to display chilled water flow and determine operating performance 2 way 3 way Floating Point Valve CW Only A floating point valve is microprocessor controlled to regulate the amount of chilled water into the cooling coil to maintain desired conditions The standard valve pressure rating is 4136 8 kPa 600 psig The maximum operation pressure of the unit is 2068 4 kPa 300 psig The valve is user configurable to be two way or three way Counterflow Cooling Coil Condensate Pan Designed for high sensible heat rat
41. be coils Fin shall be a minimum of 0 0055 in thick Tube wall shall be a minimum of 0 016 in thick Coil tube sheets shall be a minimum 1 2 mm 18 gauge G90 galvanized steel Coil shall be rated for a maximum pressure of 2757 9 kPa 400 psig Coil headers are equipped with drip plates in the bottom to route the condensate accumulating on the header tubes to the condensation pan Coil is configured in a counterflow arrangement to optimize heat transfer efficiency Direct Expansion Cooling coil shall use raised lance type corrugated aluminum fin and 12 7 mm 1 2 in OD copper tube coils Fin shall be a minimum of 0 0055 in thick Tube wall shall be a minimum of 0 016 in thick Coil end supports shall be a minimum 1 2 mm 18 gauge G90 galvanized steel Coil shall be rated for a maximum pressure of 3447 3 kPa 500 psig and the coils are certified in accordance with UL207 Coil header is equipped with a drip plate in the bottom to capture and direct the condensation accumulating on the suction header tube to the drain pan Coil has 6 circuits complete with brass distributor and copper distribution tubes VARIABLE SPEED COMPRESSOR VFD ASSEMBLY AIR COOLED ONLY l Compressor The unit shall be configured with a variable speed reciprocating hermetic compressor using a matched VFD As a result the compressor speed can be varied through a range between 30 and 85 Hz to accommodate varying load conditions VFD firmware is written to include oil re
42. be thoroughly insulated to minimize thermal loads and make up air if required should be preconditioned to reduce additional temperature filtration and moisture loads Service access At least 914 mm 36 in of clear space must be left in the front and rear of the unit for routine service In order to service the unit outside of the row an area of 1219 mm 48 in of clear space is required in the front and rear of the unit while it is in the row Receiving the unit Your InRow RP unit has been tested and inspected prior to shipment To ensure that you have received the unit in excellent condition perform a careful inspection of the crating and the unit immediately upon receipt Verify that all parts ordered were received as specified and that the unit is the correct size and voltage necessary to fulfill your environmental control needs Report any damage discovered to the freight carrier If necessary contact the APC field service department for help in repairing or replacing damaged parts While APC is not responsible for damage incurred in transit we want to make sure that you have no undue delays in your system start up Please refer to the unpacking sheet for more information Rigging The unit is manufactured with a formed steel frame for maximum strength and unit integrity However as with all electrical and mechanical equipment you must take care with proper rigging of your unit When using a forklift to move the unit use the shi
43. configuration is available in one size with a capacity that is up to 60 kW based on the particular application of the unit The InRow RP air cooled configuration is available in one size with a capacity that is up to 37 kW Room Air Distribution Row based systems are placed in line with rack enclosures At least one system is used per hot aisle Air is drawn in through the rear of the system cooled and discharged into the cold aisle thereby neutralizing the sensible heating effects of the data processing equipment The InRow RP delivers high volumes of airflow to eliminate hot spots in densely populated environments Configuration Chilled Water e Air cooled Compliance Approval UL Listed VDE CE e C tick C UL Listed c UL us LISTED Chilled Water Standard Features Insulated cabinet Backward inclined impeller Variable speed fans 3 Shutdown input alarm output Chilled water flow meter e 2 way 3 way floating point valve Humidifier Counter flow cooling coil Electric reheat Pleated 100 mm 4 in filter NPT to BSPT pipe adapters Topor bottom piping Condensate management with dual position float Network management card Baying Kit InRow RP to NetShelter amp SX rack Remote temperature sensor 3 Microprocessor controller Automatic transfer switch InRow RP Technical Data Manual Air cooled Standard Features Insulated cabinet Backward inc
44. essor drive warning Compressor run hours violation Compressor drive RS485 communication fault Excessive compressor cycling Air flow decreased while compressor off Suction pressure sensor failure Discharge pressure sensor failure High pressure switch active Fan speed decreased to avoid high pressure event only Compressor speed decreased to avoid high pressure event only Compressor high pressure Oilreturn pump active InRow RP Models Hinged rear doors Casters all swiveling Side panel lock Door handle and lock Removable side panel Q Display interface Q Adjustable leveling foot Hinged front door InRow RP Technical Data Manual Chilled Water Interior Components front of unit 10 TRAIT Ed ET amp UTI na2090a LER WV RTT NGT ET ETT 83 P Condensate drain pan User interface connectors Electric heater for reheat Electrical panel Fan Q Supply temperature sensors Fan guard Main feed breakers Q Humidifier Ladder diagrams 12 Condensate pump Supply humidity sensor InRow RP Technical Data Manual Chilled Water Interior Components back o
45. f unit Kee Chilled water coil Rear doors Chilled water control actuator Air filters Chilled water three way valve body Return humidity sensor Flow meter Return temperature sensor Pipe chase InRow RP Technical Data Manual 11 Air cooled Interior Components front of unit o o oO 6080 o 12 Electric heater for reheat Condensate drain pan Thermal expansion valve Receiver Compressor Variable Frequency Drive for compressor Supply air temperature sensor o00000 e Main circuit breaker Fan Fan guard Electrical panel Ladder diagrams Communication and external device connectors Humidity sensor InRow RP Technical Data Manual Air cooled Interior Components back of unit AA Evaporator coil Shutoff valves top piping only Condensate drain pan Air filters Sight glass Pipe chase Filter dryer Humidity sensor Condensate pump Return air temperature sensor Humidif
46. ier InRow RP Technical Data Manual 13 Chilled Water and Air cooled User Interface Connections na2009a 14 e e e e e e e o e e o o o o o o o o o Rack inlet temperature sensors 1 2 3 A Link IN A Link OUT Network port Console port Alarm output NC Normally Closed Alarm output COM Common Alarm output NO Normally Open Supply GND Ground Supply 12 Vdc current limit 20 mA Supply 24 Vdc current limit 20 mA Customer input 12 30 Vac Vdc 24 Vde 11 mA Supply COM BMS DI RXTX BMS RXTX BMS GND Supply air temperature sensor front Supply air humidity sensor front Display interface Note For a top installation control wiring is routed through the wire channel located at the top left hand corner just above the user interface connectors For a bottom installation the control wiring is routed to the access hole in the bottom of the equipment through wire clamps from the interface connectors Then the wiring is routed down along the electrical panel and secured with wire clamps InRow RP Technical Data Manual Chilled Water Electrical Panel Note ACRP501 shown
47. ion 3 Alarms The microprocessor controller shall activate a visible and audible alarm in the occurrence of the following events Cool Fail Rack inlet temperature violation Rack inlet temperature sensor fault Air filter clogged Air filter run hours exceeded Filter DP sensor failure Supply air sensor fault Soe Return air sensor fault re Supply air high temperature violation Return air high temperature violation InRow RP Technical Data Manual 39 40 i g NS af ag ah ai aj ak al am an ao ap aq ar as at au av aw ax ay az Fan fault Fan run hours exceeded Water detection fault Condensate pump fault Condensate run hours exceeded Humidifier water conductivity high violation Humidifier fault tolerance exceeded Humidifier low water Humidifier excessive output reduction Humidifier drain fault Humidifier cylinder full Humidifier replace cylinder Humidifier RS485 communication fault Humidifier run hours violation Humidity high low violation Supply humidity sensor fault Return humidity sensor fault Heater fault Heater run hours exceeded Heater interlock shutdown Group communication fault Internal communication fault A link isolation relay fault External communication fault Input contact fault Invalid supply setpoint Idle mode active Coil fluid v
48. ios the coil is constructed with copper tubes raised lance type aluminum fins and 1 2 mm 18 gauge galvanized steel end plates Coil headers are equipped with anti drip shields in case of condensation Condensate pan 1s UL94 V 0 thermal formed non ferrous material sloped for positive drainage for higher indoor air quality Electric Reheat Electric reheat elements are low watt density wired for three phase and loaded equally on all three phases and electrically and thermally protected by both automatic and manual reset thermal cut outs Reheat elements are stainless steel fin tubular construction InRow RP Technical Data Manual 30 ASHRAE 52 1 Filter The filtration of conditioned air is extremely vital to maintaining the clean particle free environment required by electrical equipment The system uses a 30 efficient 100 mm 4 in deep loading pleated filter Deeper filters produce a lower pressure drop requiring less energy during normal operation The filter is moisture resistant up to a 100 relative humidity Filters are easily replaceable from the rear of the unit MERV 8 per ASHRAE 52 2 EN779 G4 Pipe Adapters CW only Standard pipe connections are 38 1 mm 1 1 2 in NPSM manufactured in accordance with ANSI B 1 20 1 Pipe Adapters Air Cooled only Standard pipe connections are 31 75 mm 1 1 4 in 12 UNF female Rotolock manufactured in accordance with ANSI B1 1 The adapter converts the
49. k and simple Expansion kits with necessary ceiling tile and all baying hardware can be ordered to increase the size of the hot aisle by one rack on each side The end doors can be easily removed and re attached for expansion The enclosed hot aisle prevents any warm return air from mixing with cold supply air In effect all surrounding room air can act as supply air to the system The hot aisle containment system is beneficial in any environment It can be deployed quickly in any controlled space without expensive additions to the infrastructure such as raised floor or ductwork 85 63 na2763b NetShelter NetShelter 1798 58 81 1155 70 1325 88 3037 80 45 50 52 20 119 60 NetShelter NetShelter NetShelter NetShelter Y La d d EE IL gt 600 600 600 600 600 600 23 62 23 62 23 62 23 62 23 62 23 62 Dimensions are shown in mm in InRow RP Technical Data Manual Standard Features Insulated Cabinet ll POWDER af COATED TOUGH The frame is constructed of 1 5 mm 16 gauge formed steel for maximum strength Cabinet is serviceable from the front and rear All exterior panels and corner posts on the frame are powder coated for durability and an attractive finish Front
50. lined impeller Variable speed fans 2 Shutdown input alarm output Humidifier Cross circuited cooling coil Electric reheat Pleated 100 mm 4 in filter Pipe adapters Topor bottom piping Condensate management with dual position float Network management card Bayingkit InRow RP to NetShelter SX rack Remote temperature sensor 3 Microprocessor controller Variable speed reciprocating compressor using VFD control Liquid line solenoid valve Pressure equalization solenoid Accessories Cableleak detector Bayingkit InRow RP to NetShelter VX rack NetShelter SX 42U to 48U height adapters NetShelter VX 42U height adapters Bridge trough power cable shield Data cable bridge partition Flex hose piping kits Scalable Solution for Critical Environments InRow Advantages The row based solution improves energy efficiency and cooling ability in a number of ways First the InRow RP draws air directly from the hot aisle allowing the InRow RP to take advantage of higher heat transfer efficiency due to higher temperature differences It can then discharge room temperature air directly in front of the servers it is cooling This increases energy efficiency by allowing the chiller to operate at higher leaving water temperatures Placing the cooling unit in the row enables the unit to operate at higher return and supply air temperatures yielding 10096 sensible capacity This significan
51. logged Air filter run hours exceeded Filter DP sensor failure Supply air sensor fault Return air sensor fault Supply air high temperature violation lt Return air high temperature violation lt Fan fault Fanrun hours exceeded Water detection fault Condensate pump fault Condensate run hours exceeded lt Humidifier water conductivity high violation Humidifier fault tolerance exceeded Humidifier low water Humidifier excessive output reduction Humidifier drain fault e Humidifier cylinder full lt Humidifier replace cylinder Humidifier RS485 communication fault Humidifier run hours violation Humidity high low violation Supply humidity sensor fault Retum humidity sensor fault Heater fault Heater run hours exceeded Heater interlock shutdown Group communication fault nternal communication fault A link isolation relay fault External communication fault Input contact fault Invalid supply setpoint dle mode active Chilled Water Only Alarms Coil fluid valve actuator fault Fluid flow fault Entering fluid temperature high violation Entering fluid temperature sensor fault Leaving fluid temperature sensor fault Power source failure Fluid calibration InRow RP Technical Data Manual Air cooled Only Alarms High discharge pressure Low suction pressure High suction pressure Compressor drive failure Compr
52. m support contact for contact information For information on how to obtain local customer support contact the APC representative or other distributors from whom you purchased your APC product Entire contents copyright 2009 American Power Conversion Corporation All rights reserved Reproduction in whole or in part without permission is prohibited APC the APC logo and InRow are trademarks of American Power Conversion Corporation All other trademarks product names and corporate names are the property of their respective owners and are used for informational purposes only 990 2469E 001 9 2009
53. onal filter shall be 8596 efficient per ASHRAE Standard 52 1 MERV 13 per ASHRAE 52 2 EN779 F7 HUMIDIFIER 2 Humidifier shall be able to modulate capacity The humidifier shall be self contained steam generating type factory piped and wired with disposable cylinder and automatic solid state control circuit Humidifier canisters shall be replaceable The humidifier controller shall communicate directly to the microprocessor controller and provide complete status and control at the operator interface Humidifier shall control flush cycling and conductivity via automated controls Humidifier shall be capable of producing up to 3 kg 6 6 Ib of steam per hour ELECTRIC REHEAT 1 Reheat elements shall be low watt density wired for three phase loaded egually on all three phases and shall be electrically and thermally protected by both automatic and manual reset cutouts Reheat capacity shall be 9 kW for chilled water and 6 kW for air cooled Reheat coils shall be stainless steel fin tubular construction Heater casing shall be 0 9 mm 20 gauge G90 galvanized steel Heater shall be provided with self engaging electrical connectors upon installation Heater with manually connected conductors are not acceptable TEMPERATURE AND HUMIDITY SENSORS l Internal Temperature Sensors Thermister temperature sensors shall be mounted behind the front and rear doors to provide control inputs based on supply and return air temperature Sensor
54. pping skid to protect the bottom of the unit When using chains cables or rope to lift the unit use spreader bars to prevent damage to the finished panels Four threaded M10X16 holes are provided in the top of the frame to accommodate lifting eye bolts that can be utilized to lift the unit Condensate Drain 44 Condensation from the evaporator pan is collected and discharged by the condensate pump to a 3 8 in 10 mm I D condensate line supplied with the unit Additional condensate piping is required to route to building condensate system NOTE Because of an ongoing program dedicated to product improvement specifications are subject to revisions without notice APC assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions InRow RP Technical Data Manual APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests www apc com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides customer support information www apc com support Global support searching APC Knowledge Base and using e support Contact the APC Customer Support Center by telephone or e mail Local country specific centers go to www apc co
55. re resistant up to a 100 relative humidity Filters are easily replaceable from the rear of the unit MERV 13 per ASHRAE 522 EN779 F7 Power Trough Overhead power distribution between adjacent NetShelter racks allows for removal of the InRow RP without disrupting overhead power cabling InRow RP Technical Data Manual Data Partition Overhead cable distribution between adjacent NetShelter racks allows for removal of the InRow RP without disrupting overhead cabling Height Adapters To match height of the InRow RP to various rack heights height adapters are available for NetShelter 420 VX and 48U SX racks Flex Hose Piping Kits For hard piping to the chilled water InRow RP stainless steel flex piping kits are available The kits ship with two 0 914 m 3 ft or 1 828 m 6 ft pipes depending on selection Connections are 1 25 in NPT to 1 5 in NPSM OFS female Microprocessor Controller Microprocessor Controller The microprocessor controller is standard on each system The controller provides precision control for the demanding requirements of Computer rooms Telecommunication facilities Clean rooms Power equipment Medical equipment rooms e LAN WAN environments The easy to use display allows the operator to select options from the device s menu driven interface to control and monitor the connected air conditioning system Open Architecture The
56. rotolock to a sweat adapter Selectable Top or Bottom Piping Connections Unit includes both top and bottom piping connections Top piping connects to internal stubs and routes piping upward out of the unit Bottom piping connects to internal stubs and routes piping downward out of the unit All connections utilize unions or rotolok fittings for ease of installation and service Dual Position Float Condensate Management The pump is factory wired and piped internally to the condensate drain pan and humidifier outlet The pump is capable of pumping a maximum of 18 m 60 ft at 0 009 1 5 8 45 GPH which may include a maximum lift of 3 5 m 11 5 ft of head A dual position float is included with the unit One position is used for condensate pump control the other to alarm condensate pump failure which shuts down the RP to prevent condensate pump overflow Network Management Card Permits multi level access to monitoring control and event notification features over the user s network Bay Kit InRow RP NetShelter SX Baying kits made of 1 5 mm 16 gauge steel enable baying of the cooling system to APC NetShelter SX enclosures Remote Temperature Sensors To control the unit based on rack inlet temperature three remote sensors are provided These sensors measure at 4 m 13 ft from the connection point inside the RP The sensors are used for remote placement in the field on adjacent IT racks InRow RP Technic
57. se block ACRP100 ACRP101 Compressor circuit breaker ACRP102 Fan circuit breakers Controller circuit breaker Humidifier circuit breaker Heater circuit breaker Heater contactors e e oe e e o oO o o oO o o o o Humidifier contactor o Hm o ILLI o S i O 5 i D D ana t 1 my gn seu 5 CH 16 InRow RP Technical Data Manual Performance Specifications Chilled Water Performance Specifications 5 5 C 42 F EWT Temperature dry bulb Gw Delta T Total Net Sensible Net Sensible Heat CW Flow Total CW DB wet bulb WB C F Capacity Capacity Ratio Rate Pressure Drop C F kW BTU hr kW BTU hr SHR Vs GPM kPa ft H20 26 7 C DB 17 1 C WB 80 F DB 62 8 WB 6 6 12 44 3 151 000 40 7 139 000 0 92 1 6 25 9 66 21 95 7 7 14 40 8 139 000 37 9 129 000 0 93 1 3 20 6 42 14 1 8 8 16 37 8 129 000 35 2 120 000 0 93 1 1 16 8 29 9 5 10 18 34 6 118
58. tly reduces the need for humidification Scalable for High Density The predictable performance of the row based architecture makes it well suited for high density applications The focus on heat removal instead of cold air delivery is the key to making this approach scalable The modular design of the InRow RP allows it to be easily added in the row as the demand for cooling increases The additional benefit of the row based architecture is the ability to add hot aisle containment Containing the hot aisle further reduces any chance of hot and cold air streams mixing This provides ultimate predictability and allows the cooling capacity to be matched to the IT heat load 2 InRow RP Technical Data Manual Hot Aisle Containment System Modular ceiling tiles and doors can be used to enclose the hot aisle This increases the densities that can be handled in a single rack enclosure by eliminating mixing of hot and cold air streams This method called load neutralization removes the heat from the hot aisle cools it and then returns it to the surrounding room area at or slightly below room temperature The warmer return air temperatures that are achieved in this application increase the capacity of the air conditioner Use of modular ceiling tiles across a 914 4 mm 3 ft hot aisle that connects two opposite rack enclosures makes expansion quic
59. turn protection in cases where pipe velocities may drop to low speeds during low loading periods Compressor is electrically protected through the VFD Compressor utilizes a noise cap for noise reduction Sight glass provided for air cooled system oil charging 3 WAY MODULATING VALVE CHILLED WATER ONLY 1 A floating point valve shall be microprocessor controlled to automatically direct the proper amount of chilled water in the cooling coil to maintain desired conditions A shut off valve located in the bypass line may be manually adjusted for 2 way flow if so desired Three way control valve shall be rated for 300 WOG with brass body and stainless steel ball Valve Actuator Actuator shall be direct connect rotary floating point style actuator with potentiometer feedback and should be capable of being replaced without disconnecting piping from the valve Ability for manual operation is also provided InRow RP Technical Data Manual 41 42 CONDENSATE PUMP Factory installed and wired condensate pump shall pump at 31 99 I h 8 45 at 3 5 m 11 5 ft of head Pump shall have a dual position internal float and a reservoir made of polymeric materials to prevent corrosion FILTERS l The standard filters shall be 30 efficient per ASHRAE Standard 52 1 UL Class 2 8 per ASHRAE 52 2 Filters shall be EN779 G4 efficient The 96 mm 3 75 in deep pleated filters shall be replaceable from the rear of the unit The opti
Download Pdf Manuals
Related Search
Related Contents
Captioning - National Court Reporters Association EN13 manual WLG25USB UG Aerocool XPredator BR USER`S MANUAL Nesis II - Kanardia 20. Korrosionsschutz des Kessels Kit detection de drogue sur matière Héroine Brune+Blanche-2200 User Manual - Simply Computer Software, Inc. Copyright © All rights reserved.