WMG-Administrator! Messaging Switch Software Installation

image

Contents

1. P T ooopana oop Power Distribution Panel O OJ Blank Panel Ol O Ol Blank Panel O Ol OJ Blank Panel O OJ Ba l 1 UCC O S 9 O Ol lll a iii ai UCC lo 7 fe Ml Mi A Te ucc r o fm Ol O Ol Mill f ucc lo Ve ol o d Blank Panel ef alee SB SE lt 8 By ik fa Power Inverter a 9 8 b d Blank Panel z Figure 1 3 WMG MS Typical DC Powered Third Cabinet Configuration with Four UCCs April 1998 6880493G51 A 1 9 Introduction WMG Administrator Messaging Switch Software Installation Wireless Message Gateway Control Center The Wireless Message Gateway Control Center is the user interface to the WMG MS Using the graphical interfaces system operators can oversee and manage WMG MS operations such as system configurations statistics alarms classes of service and subscriber administration Using an x terminal to access the Wireless Message Gateway Control Center operators can perform the following tasks e Configure system parameters e Administer Wireless Message Gateway Control Center user permissions e View WMG MS statistics and alarms e Define classes of service and subscriber profiles The Wireless Message Gateway Control Center provides the following features
2. 30 Disconnect the cable going from Port 1 on the back of the Terminal Server and the NCD serial port This completes the procedure for configuring the WMG MS terminal Repeat the above procedure for the remaining terminal servers using the corresponding IP addresses see Appendix B April 1998 6880493G51 A 2 31 Installing WMG System Software WMG Administrator Messaging Switch Software Installation NCD User Services Terminal Emulator E File Options Fonts Cursors Keys change Change login and or admin password gateway Examine modify gateway table host Examine modify host table kill Kill TCP connections on serial line line Terminal configuration organised by line port Terminal configuration organised by port quit Return to connections menu server Examine modify Server parameters stats Examine Server statistics trap Examine modify SNMP Trap parameters x Terminal server shutdown in progress tservi Loading initialisation file tftpboot iolan3502 config Received 10K in 0 seconds average 10K sec Cksum 0 tservi 904 Image load complete Figure 2 15 Administration Menu Terminal Server Configuration for TNPP optional Note This procedure assumes that power is shut off to the terminal server 1 Connect the serial cable from the NCD console serial port to port 1 on Terminal Server 2 2 Turn on power to Terminal Server 2 3 Verify that the power indicator on the power sw
3. You have now completed the ethernet switch software configuration to the specifications of the WMG MS Note Repeat this procedure for each ethernet switch in the system 2 42 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software Configuring File Server Software To configure the File Server FS connect a terminal server serial port to the serial console port on the file server This terminal server port was configured in terminal server configuration procedures Before configuring the FS ensure that both Power Distribution Panel switches are turned on for the FS There is one power circuit for the Redundant Array of Independent Disks RAID and a separate power circuit for the system controller If possible power up the RAID before applying power to the controller Setting Up the FS 1 Insert Network Appliance System Bootup Disk version 3 1 4d 2 From the Terminal Emulator window at the omc prompt type the following telnet tserv1 10004 lt Return gt 3 Push the power distribution switch for Disk Storage RAID to the ON position 4 Verify that both disk storage power supply LEDs left front above power connector top is shelf status bottom is power supply status are ON green 5 Push the power distribution panel switch for the file server to ON position 6 Push the file server power switch to ON position 7 Verify that the file server LED status
4. TouchTone DTMF dual tone multifrequency Transaction ID The identification used to note a particular event related to the message flow within the system typically used to identify a particular message for acknowledgment Transmitter A radio station device that transmits the outbound radio protocol to the PMU Transport Medium Method of transporting data from one location to another wireline wireless network Trunk A single voice channel within a telephone span line 30 trunks for E1 24 for T1 Urgent A message condition that indicates that the system will notify the subscriber when these messages are present in the DMS or the Mailbox before notifying of the presence of other messages Voice Mail Common term for the Audio Mailbox Table A 2 Telecommunications Terminology Sheet 1 of 6 Name or Acronym Definition 80486 A 6 A microprocessor from Intel 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Wireless Messaging System Terminology Table A 2 Telecommunications Terminology Sheet 2 of 6 Name or Acronym Definition ACK Acknowledge AMG Motorola s Advanced Messaging Group Bell 103 Modem line specification 300 bps Bell 202 Modem line specification 1200 bps BellCore Bell Communications Research BMS Billing Management System Capcode PMU radio signaling
5. 38 39 40 41 42 43 45 46 47 48 49 50 51 52 53 54 DO Press lt Select gt until IP BYTE 3 0 appears on the printer display Press lt Item gt until IP BYTE 4 0 appears on the printer display Press lt Value gt then lt gt until IP BYTE 4 50 appears on the printer display Press lt Select gt until IP BYTE 4 50 appears on the printer display Press lt 60 gt to place the printer in the on line mode Press lt Item gt until SM BYTE 1 appears on the printer display Press lt Value gt then lt gt until 255 appears in the printer display Press lt Select gt Press lt Item gt button until SM BYTE 2 appears on the printer display Press lt Value gt then lt gt until 255 appears in the printer display Press lt Select gt Press lt Item gt until SM BYTE 3 appears on the printer display Press lt Value gt then lt gt until 0 appears in the printer display Press lt Select gt Press lt Item gt until SM BYTE 4 appears on the printer display Press lt Value gt then lt gt until 0 appears in the printer display Press lt Select gt Press lt Item gt until LG BYTE 1 appears on the printer display Press lt Value gt then lt gt until 10 appears in the printer display Press lt Select gt 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System
6. Table 1 1 Conventions Used in This Manual Example Convention Description lt Return gt Dual angle brackets lt gt Hila keys or Ned irae a lt Control O gt Dual angle brackets and plus sign rom thie keyboard lor key commands ine 1 plus sign indicates to hold down the first key lt ctrl o gt and press the second key Ok button Palatino bold Indicates fields in a GUI requiring input or File pull down menu Palatino bold plus single bracket gt activation or menu pull down and pop up File gt New commands hs ucc vru config chn_data Lowercase Helvetica Indicates system output for example information displayed in the GUI and x terminal windows hs ucc vru config chn_data Lowercase Helvetica bold 6880493G51 A Indicates system input for example information entered into the system by the user April 1998 WMG Administrator Messaging Switch Software Installation Introduction WMG MS Overview The Motorola WMG MS is designed for the advanced messaging industry The WMG MS maintains the subscriber database receives message inputs and manages information such as voice mail services For valid remote callers the system sends the message over the Wide Area Network WAN to the remote messaging switch for processing The local transmitter broadcasts the messages The WMG MS offers several messaging applications which require increased message processing file storage system availability and
7. 17 Verify that the system SCSI IDs are properly set type probe scsi all lt Return gt For Ultra based systems type Y lt Return gt to continue 18 Verify the following settings For Themis based systems target 3 OMC disc drive target 4 4 mm DAT tape drive target 6 external CD ROM drive For Ultra based systems target 0 OMC disk drive target 4 4 mm DAT tape drive target 6 external CD ROM drive This completes setting the OMC open boot parameters April 1998 6880493G51 A 2 15 Installing WMG System Software WMG Administrator Messaging Switch Software Installation Defining the OMC System Identification and Configuration Configure the system setup information before running the WMG installation scripts 1 Insert the Solaris Hardware 2 5 1 CD ROM part number 8280520F33 into the CD ROM drive 2 Type the following at the ok prompt boot cdrom lt Return gt The boot takes approximately four minutes 3 Select the type of terminal in use see Figure 2 6 For the x terminal emulator type 12 lt Return gt NCD User Services Terminal Emulator aimi File Options Fonts Cursors Keys What type of terminal are you using ANSI Standard CRT DEC T52 DEC T100 Heathkit 19 Lear Siegler ADM31 PC Console Sun Command Tool Sun Horkstation Televideo 910 10 Televideo 925 11 Hyse Model 50 12 X Terminal Emulator xterms 13 Other Type the number of your choice and press
8. 19 20 21 22 April 1998 is the Ethernet controller in slot 0 on the mother board If the Filer has the quad ethernet port expansion option no setup is required for these ports in this WMGMS release Enter the netmask for the network interface e0 by typing 255 255 255 0 lt Return gt Select media type for network interface e0 Press lt Return gt to use the default value of tp Press lt Return gt to retain the unconfigured defaults of IP addresses for expansion ports ela elb elc or eld For each prompt a Enter the IP address for Network Interface ela lt Return gt b Enter the IP address for Network Interface e1b lt Return gt c Enter the IP address for Network Interface elc lt Return gt d Enter the IP address for Network Interface eld lt Return gt e Enter the IP address for Network Interface f8 lt Return gt At the prompt enter name of the default gateway press lt Return gt At the prompt IP address of the gateway press lt Return gt Enter the name of the administration host the voice LAN name assigned to the CP by typing omcv lt Return gt Enter the IP address of the administration host OMC by typing 177 4 78 17 lt Return gt The file server setup is complete Press lt Setup gt and open New Telnet Window Select Terminals gt New Telnet 6880493G51 A 2 45 Installing WMG System Software WMG Administrator Messaging Switch Software Installation 23
9. Motorola and FLEX are trademarks of Motorola Inc Other trademarks are noted as such throughout this document Antares and Dialogic are trademarks of Dialogic Corporation HP and LaserJet are registered trademarks of Hewlett Packard Company Intel is a registered trademark and 80286 and Pentium are trademarks of Intel Corporation UnixWare is a registered trademark of Novell Inc Solaris is a registered trademark of Sun Microsystems Inc Static Stop is a registered trademark of Barco Chemical Products Informix is a registered trademark of Informix Software Inc Trademarks contained herein are the acknowledged property of their respective owners Important Safety Information The installation maintenance and or operation of this equipment may present potentially unsafe conditions including but not limited to electrical shock improper voltage to components and improper operation that can cause personal injury death or damage to property Read Instructions Read all the safety instructions before operating the equipment Retain these safety instructions for future reference Specialized procedures and instructions are required and must be followed Also all applicable safety procedures such as Occupational Safety and Health Administration OSHA requirements National Electric Code Requirements local code requirements safe working practices and good judgement must be used by personnel April 1998 6880493G51 A v Fore
10. hall File Options Fonts Cursors Install Solaris Software Initial The screens that follow let you tailor how Solaris is installed on your system The main tasks you must perform to install Solaris software on your system are Selecting a system type Selecting Solaris software Selecting disks to hold the software youve selected Specifying how files systems are laid out on the disks After completing these tasks a summary of your selections called a profile is displayed You can go back and change selections as many times as you like before starting to install Solaris gt To continue press F2 i F2_Continue F3_Go Back FS_Exit F6_Help Figure 2 7 Install Solaris Software tnitial April 1998 6880493G51 A 2 19 Installing WMG System Software WMG Administrator Messaging Switch Software Installation NCD User Services Terminal Emulator 2 If you exit the Solaris installation program all selections youve made on screens will be deleted However you can restart the Solaris installation program from a UNIX shell gt To exit the Solaris installation program press F2 gt To cancel the exit press F5 F2_Exit Installation F5_Cancel Figure 2 8 Exit Solaris Installation Window Installing the OMC Load Tape Use this procedure to load the OMC tape 1 Verify that the 4 mm DAT installation tape is the correct part number 0180302F82 and version 2 Verify that the 4 mm DAT c
11. 6880493G51 A 2 71 Installing WMG System Software WMG Administrator Messaging Switch Software Installation 6 7 8 At the prompt type no and press lt Return gt Repeat Step 1 through Step 6 for CP2 and use cp2c as the node name to telnet to CP2 At the prompt System must be rebooted type yes and press lt Enter gt Installing the UCC System Application 1 At the omc prompt type ed wmgucc lt Return gt Type tar xvf ucc tar_file lt Return gt At the omc prompt type chmod x ucc_app_ install ucc_extract ucc_chan_cfg lt Return gt Verify that the mode was changed type Is al ucc_app_install ucc_extract ucc_chan_cfg lt Return gt Execute the script type ucc_app_install lt Return gt The UCC Application Installation window appears see Figure 2 29 NCD User Services Terminal Emulator File Options Fonts Cursors eH X KKK KK KK HH ed wmgucc tar xvf tar_file README ucc 4475 bytes 9 tape blocks channel_cfg 49340 bytes 97 tape blocks ucc tar 22732800 bytes 44400 tape blocks ucc_app install 1922 bytes 4 tape blocks ucc_chan_cfg 5131 bytes 11 tape blocks ucc_extract 3862 bytes 8 tape blocks ucc_install tar 174080 bytes 340 tape blocks wmgdsp cof 251078 bytes 491 tape blocks chmod x ucc_app install ucc_extract ucc_chan_cfg ls al ucc_app_install ucc_extract ucc_chan_cfg r xr xr x 1 51087 7002 1922 Dec 3 19 56 ucc_app_install r xr xr x 1 51087 7002 5131 Dec
12. 2 Identify your system 3 Install Solaris software About navigation The mouse cannot be used If your keyboard does not have function keys or they do not respond press ESC the legend at the bottom of the screen will change to show the ESC keys to use for navigation F2_Continue F6_Help Figure 2 25 Solaris Installation Program Window 4 Press lt F2 gt to continue The Identify This System window appears 5 Press lt F2 gt to continue The Host Name window appears 6 Type the host name that is cp1 or cp2 of the system and press lt F2 gt to continue The Network Connectivity window appears 7 Use the arrow keys to select Yes for Networked and press lt F2 gt The Primary Network Interface window appears 8 Accept the default for the primary network interface Press lt F2 gt to continue 2 62 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 10 11 12 13 14 15 16 17 18 April 1998 The IP Address window appears Type the Internet Protocol IP address for the onboard ethernet interface le0 or hme0 this is the IP address for the host name For CP1 type 177 3 77 10 lt F2 gt For CP2 type 177 3 77 11 lt F2 gt The Confirm Information window appears Verify that the network information entered in the previous windows If the information is correct press lt F2 gt to co
13. Messaging Switch Software Installation 31 Type shutdown y g0 i6 lt Return gt The UCC SCO UnixWare OS installation is now complete 3 44 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software Restoring the UCC System Cloning Tape Use this procedure to restore the SCO UnixWare software Antares and Dialogic packages Set up the system software in preparation for installation of UCC system application software The symbol UCC gt is the UCC prompt to input information as described below Note UCC hardware WinBIOS and ethernet boards must be configured identically to the master system the UCC used to create the clone tape A clone tape for each UCC must be previously created and the replacement hard drive must be identical to the original for this procedure to work If the replacement hard drive is not identical to the original you must start with the first procedure in this chapter see paragraph Running the WinBIOS Setup The entire process takes approximately eight hours Hardware Requirements e External DAT tape drive e SCSI cable e VGA board e VGA monitor Software Requirements e System Recovery disks 2 for SCO UnixWare 2 1 1 e System Recovery DAT tape 1 for SCO UnixWare 2 1 1 Procedure Perform the following steps for systems that have UnixWare and UCC application software currently installed 1 From the SCO UnixWare 2 1 1 log
14. N Press lt Esc gt to save the changes and return to the Setup menu 9 Select Advanced from the main menu and press lt Return gt The Advanced Setup window appears Note To change a setting press the lt Return gt key to access the Options pop up menu Use the arrow keys to toggle choices 9 Define the Advanced Setup settings see Table 3 2 Some fields do not apply to all versions The UCC Version column identifies fields specific to a certain UCC version Table 3 2 Advanced Setup Window Settings Sheet 1 of 2 Field Setting UCC Version Typematic Rate Chars S 30 166 MHz box Ver R03 System Keyboard Absent Primary Display Absent Above 1 MB Memory Test Disabled Memory Test Tick Sound Disabled Parity Error Check Enabled 166 MHz box Ver R03 3 6 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software Table 3 2 Advanced Setup Window Settings Sheet 2 of 2 Field Setting UCC Version Hit DEL Message Display Enabled Extended BIOS RAM Area 0 300 166 MHz box Ver R03 Wait For F1 If Any Error Disabled System Boot Up Num Lock Off Floppy Drive Seek At Boot Enabled Floppy Drive Swapping Disabled System Boot Up Sequence A C Password Checking Setup Cache Memory Both Adapter Shadow Cacheable Disabled System BIOS Shadow Cacheable Enabled ISA Video Shadow C00
15. Time Zone type the appropriate time zone and press lt Return gt 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software 16 Press lt Return gt to reboot UCC The UCC system configuration is complete April 1998 6880493G51 A 3 41 Installing the UCC Software WMG Administrator Messaging Switch Software Installation Generating the Clone Tape Generate a clone tape for each UCC in the system This procedure reduces the recovery time of new hard drive replacement to approximately an hour 1 Plug in and power up the tape drive 2 Set the SCSI ID to 2 3 Verify that two 3 5 in 1 44 MB disks and a 4 mm DAT tape are available for use Note Ifthe system is running type lt Control Alt Del gt to reboot During the memory test power down the UCC 4 Power on the UCC 5 At the root prompt type root lt Return gt 6 At the password prompt type motorola lt Return gt 7 To set the run level to 1 type init 1 lt Return gt 8 At the root prompt type root lt Return gt 9 At the password prompt type motorola lt Return gt 10 From the prompt type sysadm format lt Return gt The UnixWare Operations Administration and Maintenance window appears 11 Insert a blank disk in the UCC drive 12 Select Diskette for Devices Available lt F3 gt 3 42 6880493G51 A April 1998 WMG Administrator Messaging Switch Sof
16. Wireless Messaging System Terminology WMG Administrator Messaging Switch Software Installation A 12 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Appendix B IP Addresses and Network Diagram This appendix contains the default IP addresses for WMG MS and a network diagram for VME based Themis systems The subnet mask for 10 x x is 255 255 0 0 The subnet mask for 17 x x is 255 255 255 0 Table B 1 WMG MS Address Assignments Sheet 1 of 2 IP Address Host Name Subsystem Name Connect to LAN 177 4 77 17 omcc qel OMC 177 4 78 17 omcv qed 10 5 0 2 omc hme0 OMC 177 7 77 16 omcterm1 OMC Terminal OMC 177 7 77 17 omcterm2 OMC Terminal optional OMC 177 4 77 35 tserv1 Terminal Server OMC 10 4 0 2 cp1_rfc qel RFC 177 4 78 10 cplv qed 177 4 77 10 cpic qe2 177 7 77 12 cp1dcc 177 3 77 10 cp1 hmeO Control 10 4 0 3 cp2_rfc qe1 177 3 77 11 cp2 hme0 177 4 78 11 cp2v qed 177 4 77 11 cp2c qe2 177 7 77 13 cp2dcc 177 4 77 61 ucc1dci 177 4 77 101 ucc1c UCC HI Control April 1998 6880493G51 A B 1 IP Addresses and Network Diagram WMG Administrator Messaging Switch Software Installation Table B 1 WMG MS Address Assignments Sheet 2 of 2 IP Address Host Name Subsystem Name Connect to LAN 177 4 78 101 ucciv UCC1c Voice 177 4 77 102 ucc2c UCC 2 Control 177 4 78 102 ucc2v UCC
17. type y lt Return gt Press lt Return gt to continue Type lt Shift gt and press lt Return gt to exit the vi editor At the prompt Do you wish to review the release notes type the appropriate response y n and press lt Return gt Eject the protocol disk Installation of the protocol is complete 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software Loading Dialogic Patches Use this procedure to load Dialogic patches 1 10 11 12 13 14 15 16 17 18 Insert the Dialogic Patches disk part number 0180302F43 into disk drive Type tar xv lt Return gt Type cd tmp patches ptr4202 lt Return gt Type Install lt Return gt Press lt Return gt at the prompts to continue At the prompt Do you want to continue type y lt Return gt At the prompt Do you want to build the new kernel type y lt Return gt Press lt Return gt to complete the patch installation Type cd tmp patches ptr4846 lt Return gt Type install lt Return gt Press lt Return gt at prompts to continue At the prompt Do you want to continue Installation type y lt Return gt At the prompt Do you want to build the new kernel type y lt Return gt Press lt Return gt to complete the patch installation Remove the floppy disk from UCC Type cd lt Return gt Type shutdown y g0 i6 lt Return gt The system
18. 2 72 Figure 2 30 UCC File Extraction Window 2 74 Figure B 1 Themis Based Systems Network Diagram B 3 xvi 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation BF 21 gt Table 1 1 Table 2 1 Table 3 1 Table 3 2 Table 3 3 Table 3 4 Table 3 5 Table 3 6 Table 3 7 Table 3 8 Table A 1 Table A 2 Table B 1 April 1998 Conventions Used in This Manual 1 4 Terminal Server Navigation Keys 2 25 Using WinBIOS Navigation Keys 3 5 Advanced Setup Window Settings Sheet 1 of 2 3 6 Chipset Setup Window Settings 3 8 Chipset Setup Window Settings 3 9 Peripheral Setup Window Settings 3 10 Using EZStart Navigation Keys 3 11 Ethernet Board Settings 3 14 Using UnixWare Navigation Keys 3 15 The Wireless Messaging System Glossary List Sheet 1 of 6 A 1 Telecommunications Terminology Sheet 1 of 6 A 6 WMG MS Address Assignments Sheet 1 of 2 B 1 6880493G51 A xvii WMG Administrator Messaging Switch Software Installation xviii 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Chapter 1 Introduction This manual describes the WMG Administrator Messaging Switch WMG MS software installation and includes information on the following topics About This Manual 1 2 Purpose 1 3 Audience 1 3 Other Publications 1 3 Conventions Used in this Manual 1 4 WMG MS Overview 1 5 WMG MS Subsystems and Peripherals 1
19. 3 19 56 ucc_chan_cfg r xr xr x 1 51087 7002 3862 Dec 3 19 56 ucc extract ucc_app_instal1 Figure 2 29 UCC Application Installation Window 2 72 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 6 Input the UCC ID number of the UCC being installed For the UCC type 1 lt Return gt Or for the second UCC type 2 lt Return gt 7 Press lt Return gt to continue The UCC File Extraction screen appears 8 Extract the tar file Type Y from the prompt Do you want to extract the tar file Note Note Once the tar file extraction has been done for the first UCC it is unnecessary to repeat it for the second UCC 9 Typen to install from DAT tape 10 Type wmgucc lt Return gt for the install directory location The UCC File Extraction window appears see Figure 2 30 11 Press lt Return gt to continue April 1998 6880493G51 A 2 73 Installing WMG System Software WMG Administrator Messaging Switch Software Installation NCD User Services Terminal Emulator eE File Options Fonts Cursors xxxkxx UCC File Extraction x Copyright C 1995 1997 MOTOROLA INC All Rights Reserved Do you want to extract the tar file Y N N1 Y Install from DAT tape y n Input the install directory location eg usr local wmgucc Figure 2 30 UCC File Extraction Window 12 Define the type of board Note Note The following secti
20. 6 Wireless Message Gateway Control Center 1 10 April 1998 6880493G51 A 1 1 Introduction WMG Administrator Messaging Switch Software Installation About This Manual The WMG Administrator Messaging Switch Software Installation manual includes the following chapters e Introduction This chapter introduces the WMG Administrator messaging switch WMG MS and provides an overview of the product functions and organization e Installing WMG MS System Software This chapter contains information and procedures for installing the WMG MS system and application software including the Solaris operating system and peripheral software for the central processor s the OMC the X terminal and the File Server FS e Installing the UCC Software This chapter contains information and procedures to reload system and application software to an existing UCC or to install and configure the software on a new UCC e Subsystem Power Up Procedure This chapter contains information and procedures for starting up the WMG MS in the proper sequence and testing each subsystem for basic functionality e Abbreviations and Acronyms Listing This appendix provides a list of telecommunications abbreviations and acronyms e IP Addresses and Network Diagram This appendix provides the factory default values and configuration for the WMG MS IP Adresses and internetwork configuration e Wireless Messaging System Terminology This appendix provides a lis
21. Available to ISA EISA 166 MHz box Ver R03 IRQ14 Available to ISA EISA 166 MHz box Ver R03 IRQ15 Available to ISA EISA 13 Press lt Esc gt to save the changes and return to the main menu 14 Select Chipset Setup from the main menu and press lt Return gt The Chipset Setup window appears 3 8 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software 15 Define the settings see Table 3 4 Table 3 4 Chipset Setup Window Settings Field Setting Advanced Power Management Disabled IRQ1 Break Event Enabled IRQ3 Break Event Disabled IRQ4 Break Event Disabled IRQ5 Break Event Disabled IRQ6 Break Event Enabled IRQ7 Break Event Disabled IRQ8 Break Event Disabled IRQ9 Break Event Disabled IRQ10 Break Event Disabled IRQ11 Break Event Disabled IRQ12 Break Event Enabled IRQ13 Break Event Disabled IRQ14 Break Event Disabled IRQ15 Break Event Disabled Note Do not set the unlisted events 16 Press lt Esc gt to save the changes and return to the Setup menu 17 Select Peripheral from the menu and press lt Return gt The Peripheral Setup window appears 18 Define the settings see Table 3 5 April 1998 6880493G51 A 3 9 Installing the UCC Software WMG Administrator Messaging Switch Software Installation Table 3 5 Peripheral Setup Window Settings Field Setting UCC Version Programming
22. Default Use only the Setup window for the initial UCC software configuration WinBIOS Keyboard Conventions Table 3 1 Using WinBIOS Navigation Keys Key Description lt Enter gt Press Enter key to make a selection and continue Return lt Tab gt Press Tab key lt Esc gt Press Esc key lt Del gt Press Del key Arow Kev Press the left right up down keys to move the cursor to the left of right of y above below the current location lt gt oe Press the lt gt and lt gt keys to adjust values lt Alt H gt Press the Alt key and the letter H for online help Procedure Follow these steps to run the WinBIOS Setup program 1 Turn on the Power Distribution Panel PDP switch for UCC1 2 Power up UCC1 the switch is inside the right front door 3 Verify that the power LED is ON green April 1998 6880493G51 A 3 5 Installing the UCC Software WMG Administrator Messaging Switch Software Installation Pe Press lt Del gt to run WinBIOS Setup during memory testing and scanning The WinBIOS Setup menu appears g Select Standard from the main menu and press lt Return gt The Standard Setup window displays five icons a Define the setting and press lt Esc gt after each entry a Date use lt gt and lt gt to set the current date and time b Floppy A 1 44 MB 3 5 in c Floppy B Not Installed d Master Disk SCSI e Slave Disk Not Installed
23. Installing WMG System Software WMG MS Software Installation Overview The factory installs and configures software and for the WMG MS subsystems and peripherals In some cases software must be loaded at the site for upgrades system expansion or troubleshooting This chapter provides procedures for loading the WMG MS software including the Solaris version operating system and software for the following subsystems e X terminal e Operation and Maintenance Center OMC Central Processor CP 1 CP2 e Terminal Server TS e File Server FS Software Used by the WMG MS The WMG MS uses the following vendor software for processing and managing messages Solaris operating system for the CP Informix for the system database e Network Appliance for the FS Special Precautions and Instructions e Prior to starting any procedure check that all calibration stickers on the test equipment are current e Equipment can be damaged by improper cable installation Ensure that cables are correctly oriented with their jacks prior to mating e Adhere to all warnings on equipment and in operating instructions e Always observe static safety precautions when handling static sensative parts April 1998 6880493G51 A 2 3 Installing WMG System Software WMG Administrator Messaging Switch Software Installation System Software Installation Required Materials At the system level the WMG MS uses the Solaris operating system an
24. NIS Installation and Configuration window select No for Configure NIS Now Select Apply and press lt Return gt From the Mouse Selection window type 4 No Mouse and press lt Return gt 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software 52 At the Owner s Account window type a Owner s name wmgucc lt Return gt b Owner s login ID wmguce lt Return gt c Owner s user number 101 lt Return gt 102 for UCC2 103 for UCC3 53 Select Apply and press lt Return gt 54 Press lt Return gt to continue Note Keep a record of the owner s name and login ID for reference The next window prompts you to enter passwords for New Password Root Password and Administrator s Password 55 Type motorola for each password new password root password and Administrator s password and press lt Return gt 56 When prompted to confirm the password type the password again and press lt Return gt 57 From the SCO UnixWare log in window type motorola for the password and type wmgucc Press lt Return gt to log on Note For this stage of the UnixWare installation open an icon by moving the yellow outline box to it and pressing lt Spacebar gt Then press lt Alt F gt to open the File menu Scroll down the File menu and select the Open option This opens the icon To back out of the window select lt Alt F gt to open the File menu scroll down th
25. Node Name type ucc1c lt Return gt The UCCs are named ucclc ucc2c Use the proper UCC name 21 Set Date and Time to the current date and time and select the appropriate time zone from the displayed list Press lt F10 gt to apply April 1998 6880493G51 A 3 17 Installing the UCC Software WMG Administrator Messaging Switch Software Installation 22 Read the messages contained in the Install Menu and press lt Return gt to continue 23 From the Install Menu select View or Change Package Selection lt Return gt The Package Selection window appears In the Package Selection window use the arrow keys to move around the window and the spacebar to select or deselect the parameters 24 Press lt F5 gt to select all 25 Use the arrow keys to move the cursor and lt Spacebar gt to deselect the following packages a Basic UnixWare Packages Additional Platform Utilities Language Supplement Printer Support b Networking Packages NetWare Networking NetWare UNIX Client NetWare Integration Kit c UnixWare Documentation All User and Administration documentation d Graphics Packages DynaText Document Browser e Page down using the lt PgDn gt key f Advanced UnixWare Auditing Optimizing C Compilation System 26 Press lt Return gt to return to the Install Menu 27 Select Accept All Settings and Install Now lt Return gt Note The installation process takes approximately 30 minutes 28 Re insert t
26. Note Add the patches in the following order 06 05 07 15 When all the patches are installed type cd lt Return gt 16 Type shutdown y g0 i6 lt Return gt The system reboots to the SCO UnixWare window Installation of the UnixWare patch is complete 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software Installing E1 or T1 Dialogic Software Perform the following steps to install the E1 or T1 Dialogic board software 1 10 From the SCO UnixWare 2 1 1 login window press lt AIt E gt to exit At the root prompt type root lt Return gt At the password prompt type motorola lt Return gt Insert the Dialogic SR 4 2 disk part number 8280520F39 number 1 of 10 in the UCC drive Type installpkg lt Return gt Type F to install from a floppy disk Press lt Return gt to continue The system displays installation in progress messages To confirm the drive number you wish to install from default 0 1 type 0 lt Return gt At the prompt Do you wish to continue with the installation type Y lt Return gt Type the full directory path for tmp directory and press lt Return gt Note Depending on the Dialogic packages you choose to install you may have the option of 11 12 April 1998 installing libraries At the prompt Do you wish to install the available libraries yn type N lt Return gt At t
27. Press lt Select gt Press lt Item gt until TIMEOUT appears on the printer display Press lt Value gt Press lt gt until 90 appears in the printer display Press lt Select gt Local printer set up is complete for HP 5M Defining a Network Printer Use this procedure if using a network printer 1 From the omc prompt type jetadmin lt Return gt The HP JetAdmin main menu appears Select Configuration type 1 lt Return gt The Configuration menu appears Select Add printer to local spooler type 3 lt Return gt Enter the network printer name type laserjet lt Return gt The printer parameters menu appears Type 6 lt Return gt for Additional printer configuration Type 1 lt Return gt for Model Script The Model Script Printer screen appears Based on the printer model enter the following a Ifthe printer type is a 4MP type net_lj4x lt Return gt a Ifthe printer type is a 5M type net_I5jx lt Return gt The Configurable Parameters screen appears Type 4 lt Return gt to change the True End Of Job to OFF 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 10 11 12 13 14 15 April 1998 If the Banner Page Option is ON Type 5 lt Return gt to change to OFF Type q lt Return gt to move to the queue parameters screen Type 5 lt Return gt to change the default queue to YES Type 0 lt Retu
28. Return 128 Figure 2 6 Terminal Selection 2 16 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 10 11 12 April 1998 Read the display and press lt F2 gt to continue The Identify This System window appears Read the display and press lt F2 gt to continue The Host Name window appears Type the host name for the system ome lt F2 gt The Network Connectivity window appears Accept the default for Networked Yes lt F2 gt The IP Address window appears Type the factory default for the OMC 10 5 0 2 lt F2 gt The Confirm Information window appears Verify that the network information entered in the previous windows is correct If the information is correct press lt F2 gt to continue The Name Service window appears Provide the name service information a Use the arrow keys to select None for the name service b Press lt Return gt to mark the selection c Press lt F2 gt to continue The Confirmation Information windows appears Press lt F2 gt to continue The Subnets window appears Specify that the system is part of a subnet a Use the arrow keys to select Yes b Press lt Return gt to mark the selection c Press lt F2 gt to continue The Netmask window appears 6880493G51 A 2 17 Installing WMG System Software WMG Administrator Messaging Switch Software Installation 13 Define th
29. Return gt At the prompt type Y to verify that the following information is correct T1 E1 voice INI HD 1 Address E0000 IRQ 10 Modtype SCBUS The message repeats for each T1 or E1 board in the system Press lt Return gt to continue the installation At the prompt press lt Return gt to continue the installation At the prompt insert disk number 2 into the drive and press lt Return gt At the prompt insert disk number 3 into the drive and press lt Return gt At the prompt insert disk number 4 into the drive and press lt Return gt At the prompt insert disk number 6 into the drive and press lt Return gt The system displays the prompts Finished reading from diskettes Please wait Installing Voice Development Package Install in progress Press lt Return gt to continue the installation 6880493G51 A 3 31 Installing the UCC Software WMG Administrator Messaging Switch Software Installation 31 32 33 34 35 36 37 38 3 32 At the prompt Would you like to review release notes YN type the appropriate response The system displays the messages Based on your configuration Dialogic drivers will now be installed The installation of the Dialogic Generic Voice Development Platform Version 4 2 is now complete Press lt Return gt to continue the installation The system displays Installing NETWORK Development Package Install in progress Press lt Return gt to contin
30. Subscriber Storybook Personal Address The individual Radio Channel Address used to send a message to a particular PMU PMU Serial Number An identifying number unique to each PMU Private A message condition that indicates that the message cannot be transferred diverted or transmitted to another subscriber other than the originally intended subscriber Private Mailing List A subscribe defined group used for Mailbox messaging Prompt A tone or voice indication to the caller that provides information about the caller s choices and responds to the caller during a message entry session or a subscriber information management session Radio Channel Address The identification used by the radio signaling protocol to address a PMU inbound and outbound sometimes called RIC or Capcode ReceiveList List of canned texts that a PMU uses to interpret outbound alphanumeric messages Receiver A radio receiving device that receives the inbound messages from the PMU RF Audience Receiver Concentrator A device that receives data from the receivers and forwards it to the messaging system A 4 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Wireless Messaging System Terminology Table A 1 The Wireless Messaging System Glossary List Sheet 5 of 6 Term Description Registration The PMU s identification of itself and its locatio
31. System and Database 2 13 Setting the OMC Open Boot Parameters 2 13 Defining the OMC System Identification and Configuration 2 17 Installing the OMC Load Tape 2 21 Disconnecting the OMC CD ROM Themis Systems 2 23 Configuring the Terminal Server 2 25 Terminal Server Configuration 2 26 Terminal Server Configuration for TNPP optional 2 31 Configuring the Ethernet Switch 2 36 Setting the Ethernet Switch System Level Parameters 2 37 Setting the Ethernet Switch Bridge Level Parameters 2 38 Setting IP Level Parameters 2 39 Configuring File Server Software 2 42 Setting Up the FS 2 42 Local Printer Setup 2 47 Setting up the HP4MP 2 47 Setting up the HP5M 2 49 Defining a Network Printer 2 53 Installing the WMG CP Operating System 2 55 Loading CP1 Tape and Boot CD ROM 2 55 Setting the CP1 Open Boot Parameters 2 57 Setting the Open Boot Parameters 2 58 Identifying the CP1 System 2 59 Loading the CP1 Installation Tape 2 64 April 1998 6880493G51 A 2 1 Installing WMG System Software WMG Administrator Messaging Switch Software Installation Disconnecting the CP1 CD ROM 2 66 Loading WMG Applications 2 68 Overview 2 68 File Server Configuration 2 68 OMC System Application Installation 2 69 Creating the OMC Database 2 69 CP1 or CP2 System Application Installation 2 70 Installing the UCC System Application 2 71 2 2 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation
32. Type 10 5 0 2 OMC and press lt Return gt 24 At the omc prompt type the following mount fsv mnt lt Return gt cd mnt lt Return gt tar xvf usr local wmg config Utilities fileserv31c 3 1 4d tar_i lt Return gt cd lt Return gt umount mnt lt Return gt 25 Return to the FSV Telnet window type telnet fsv and press lt Return gt 26 Type passwd and press lt Return gt 27 Enter motorola twice to confirm the password 28 Type maxfiles 99999999999 The system displays max inode count cannot exceed lt nnnnn gt 29 Type maxfiles lt nnnnn gt the number obtained in Step 28 30 Type download lt Return gt 31 Remove the System Boot disk 32 Type reboot and press lt Return gt The system reboots as indicated by the prompt for a password see Figure 2 20 33 Press lt Cntl 1 gt 34 At the prompt telnet gt type quit lt Return gt The file server is configuration is complete 2 46 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software NCD User Services Terminal Emulator ud File Options Fonts Cursors Keys Tue Apr 22 07 36 54 CDT rc System shut down with reboot command Testing SIO Testing LCD Probing devices Open Firmware by FirmWorks Copyright 1995 FirmVorks all rights reserved 1 4_i Testing 64MB Complete Finding image Loading 4 4 disk 0 Complete Starting NetApp Release 3 1 4d Mon A
33. Voice boards in the system 0 lt Return gt Enter the number of T1 E1 Frontend HD boards in the system 0 lt Return gt Enter the number of T1 E1 voice INI HD boards in the system 0 Type the number 1 2 or 3 of E1 or T1 boards your system has and lt Return gt Enter the selected IRQ level for all T1 E1 voice INI HD boards 5 10 lt Return gt Enter the memory address for all T1 E1 voice INI HD boards D8000 E0000 lt Return gt Enter the board ID 0 F for T1 E1 voice INI HD board 1 0 1 lt Return gt Note If your system has two E1 or T1 boards proceed to Step 18 otherwise skip to Step 20 3 30 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software 18 At the prompt Enter the board ID 0 F for T1 E1 voice INI HD board 2 2 type 2 lt Return gt Note If your system has three E1 or T1 boards proceed to Step 19 otherwise skip to Step 20 19 20 21 22 23 24 25 26 27 28 29 30 April 1998 At the prompt Enter the board ID 0 F for T1 E1 voice IN HD board 2 3 type 3 lt Return gt At the prompt Enter the module type for T1 E1 voice INI HD board 1 NETWORK type SCBUS lt Return gt At the prompt Enter the number of LSI Frontend HD boards in the system 0 press lt Return gt At the prompt Enter the number of D 41E TYPE boards in the system 0 press lt
34. a menu option and press lt Return gt The IP Level menu appears see Figure 2 18 ping Send an ICMP echo request statistics Display statistics Type q to return to the previous menu or for help Select menu option ip inter Menu options summary Display summary information detail Display detail information define Define a new interface modify Modify an existing interface remove Remove an interface addAdvertisement Add an advertisement address removedAdvertisement Remove an advertisement address Type q to return to the previous menu or for help Select menu option ip interface define Enter IP address 177 4 77 30 Enter subnet mask 255 255 0 0 Enter cost 1 Enter interface type management management Enter advertisement address es 177 4 255 255 Figure 2 18 IP Level Parameters 2 Type inter at the prompt Select menu option ip and press lt Return gt The IP Interface menu appears 3 At the prompt Select menu option ip interface type def and press lt Return gt a Enter the IP address for enet1 or enet2 177 4 77 30 for enet1 or 177 4 77 31 for enet2 b Enter the subnet mask type 255 255 255 0 and press lt Return gt c Enter broadcast address press lt Return gt to accept the default 2 40 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 10 11 12 13 14 15 16 Ap
35. can contain any number of characters but only the first eight characters in the password are significant For example if you create alb2c3d4e5f 6 as your root password you can use alb2c3d4 to gain root access You will be prompted to type the root password twice for security the password will not be displayed on the screen as you type it gt If you do not want a root password press RETURN twice Root password Jj Press Return to continue Figure 2 28 Root Password Window 5 Type motorola or a specified root password as the root password and press lt Return gt 6 Record the root password for future use 7 At the prompt repeat the password entry to confirm 8 Login to the CP1 by typing root for the login name and press lt Return gt 9 Type motorola or a specified root password and press lt Return gt The WMG MS installation script is complete April 1998 6880493G51 A 2 67 Installing WMG System Software WMG Administrator Messaging Switch Software Installation Disconnecting the CP1 CD ROM Use this procedure to eject the DAT tape and the CD ROM 1 Type mt f dev rmt Olb rewoffl and press lt Return gt 2 Eject the CD ROM disk Type eject and press lt Return gt in the NCD Terminal Emulator window For Ultra CPs type exit at the prompt power down the CP and disconnect the serial cable Disconnecting the CP1 CD ROM on Themis Systems Use this procedure to disconnect
36. electronic information BBS for service notices and the latest software releases call the Paging One Call Support Center To request additional manuals or parts please contact the Motorola Americas Parts Division telephone 800 422 4210 facsimile 847 538 8198 To request a part number contact the Parts Identification Group telephone 847 538 0021 For Motorola Infrastructure and communicator test equipment contact the Motorola Test Equipment Center telephone 800 505 8378 April 1998 6880493G51 A iii U L JO Foreword WMG Administrator Messaging Switch Software Installation Global Service Organization Motorola provides Infrastructure and communicator technical support through authorized or company owned Service Centers Motorola also provides service for communicators on a contract basis For contract service information please contact your local Motorola representative or the Paging One Call Support Center Motorola Inc Paging One Call Support Center 5401 North Beach St MS E112 Fort Worth TX 76137 2794 telephone 800 520 7243 or 817 245 4663 facsimile 817 245 2141 Service Training Motorola through its Advanced Messaging Technical Training Group in Fort Worth Texas offers courses on communicators messaging switches transmitters and receivers These courses are taught on the site or at a customer s location Students learn to install configure and maintain Motorola messag
37. name of the terminal server type tserv1 IP address enter the IP address of the terminal server type 177 4 77 35 Subnet mask enter the value that corresponds with the IP type 255 255 255 0 Ethernet Address Accept default Language English or the appropriate language Identification leave blank Lock Disabled Password limit 5 change if desired CR to initiate Yes 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation WMG Administrator Messaging Switch Software Installation Installing WMG System Software j SNAP encoding Disabled k Boot host Type 177 4 77 17 l Boot file leave blank For IOLAN v3 5 02 leave blank For IOLAN v4 00 19 usr local wmg config iolan40019 boot m Init file modify the path to the terminal server configuration file on the CP For IOLAN v3 5 02 usr local wmg config iolan3502 config For IOLAN v4 00 19 usr local wmg config iolan40019 config n Domain name leave blank o Name server leave blank 27 Press lt Return gt 28 Select Save amp Exit from the Commands pop up menu and press lt Return gt The Administration menu appears 29 Select reboot Reboot Server press lt Return gt then press the lt Spacebar gt see Figure 2 15 The message Terminal Server Shutdown in progress appears If the reboot is successful the message Image Load Complete appears and the terminal server login prompt displays tserv1 gt
38. networking capabilities of the system The modular WMG MS architecture is upgraded as the demand for system resources increases As an integral element in the messaging network the WMG MS provides the following services Multi frequency FLEX roaming protocol One and two way tone only numeric and text messaging Integrated voice and messaging mail boxes Detailed subscriber database Graphical User Interface GUI Statistics and alarm information Callers and subscribers access the system over the Public Switched Telephone Network PSTN The system accepts standard T1 or E1 trunk spans Each WMG MS is connected to other elements in the Wireless Messaging System by a network of land lines satellite links or radio links see Figure 1 1 The addition of a return communications path creates a number of new messaging applications These applications require the WMG MS to provide increased message processing file storage system availability and networking capabilities The modular WMG MS architecture is designed to meet these needs today and as technology evolves April 1998 6880493G51 A 1 5 Introduction WMG Administrator Messaging Switch Software Installation Wireless Message Gateway Control Center 4 Sy A lt EE Ari AS annona Inputs from callers KI and subscribers RF Management System Connection to the e m Radio F through the telephone gt gt ai
39. of the following software e WinBIOS Setup e Ethernet board s e UnixWare 2 1 operating system e UnixWare 2 1 2 operating system e UnixWare 2 1 patches e UnixWare 2 1 2 patches e NIC E1 or T1 Dialogic e Global Call development e R2 protocol E1 only e UAP board e Clone install script e Cloning tape Because of the wide range of UCC functionality several software interfaces are associated with the hardware The following procedures provide navigation and keystroke information Some familiarity with PC based software behavior is helpful to perform the installation tasks 3 2 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software Required Tools and Equipment Installing the UCC software requires the following items April 1998 A CD ROM drive connected to the UCC SCSI port with the SCSI ID for the CD ROM drive set to 1 A VGA board in the UCC and a VGA monitor connected to the VGA board Two 3 5 in 1 44 MB DOS formatted disks One blank 4 mm DAT tape A SCSI DAT drive with a blank 4 mm DAT cartridge connected to the UCC A CD ROM drive is connected to the UCC SCSI port with the SCSI ID for the CD ROM drive to 1 Software for UnixWare 2 1 SCO DR DOS Bootable disk part 0180302F36 SCO UnixWare Installation disk part 0180302F36 SCO UnixWare Host Bus Adapters disk part 0180302F36 Software for UnixWare 2 1 2 SCO D
40. ok prompt type setenv diag switch true lt Return gt Note For Ultra CPs skip to Step 4 Modify NVRAM From the ok prompt type nvedit lt Return gt 5 From line 0 type xx 3e00 0003 2e spacec lt Return gt 6 From line 1 type cd obio zs 0 0 lt Return gt Note Note In the following step there is a space between the quotation mark and the letter k in the word keyword 7 From line 2 type keyboard delete atiribute lt Return gt 8 Press lt Ctrl C gt to exit nvedit 9 Store the NVRAM changes type April 1998 6880493G51 A 2 59 Installing WMG System Software WMG Administrator Messaging Switch Software Installation 10 11 12 13 14 nvstore lt Return gt At the ok prompt type setenv use nvramrc true lt Return gt Verify the changes by typing printenv lt Return gt The updated parameter information is displayed at the end of this section Reboot the processor type reset lt Return gt During the RAM tests press lt Break gt The system responds with the ok prompt Verify that the system SCSI IDs are properly set type probe scsi all lt Return gt Verify the following settings target 4 4mm DAT tape drive target 6 CDROM For Themis based CPs target 3 CP1 and CP2 disc drive For Ultra base CPs target 0 CP1 and CP2 disc drive Note Repeat the above procedure for CP2 if equipped Identifying the CP1 System 1 Insert th
41. that allows callers to use a feature Maildrop Messages that are received in a communicator that replace an earlier message in the same reserved memory location Mailbox Messages Messages deposited in the WMG for retrieval later by the subscriber Master Group A group that includes other groups and subscribers MessageBook List of canned texts used with the AddressBook for inbound messaging Message Communicator see Communicator Message Transfer The transmission of previously received messages to another destination Modem A device that converts a telephone line communication medium to a serial line medium typically used for computers to enter messages to the gateway or for remote access to the gateway Messaging Switch MS A device that can perform the following functions accepting message deposits managing the subscriber database and features or sending messages over the radio network One MS can encompass all three functions Messaging Switch Home MS A device that can manage the subscriber database and subscriber features H and store messages for each subscriber Messaging Switch Input MS I A device that can accept message deposits and send the messaging information to the MS H often the MS I and MS H are the same physical device Messaging Switch MS O A device that can send messages over the radio network and perform batching encoding and scheduling Messaging System The entire paging n
42. 0 c Required Settings I O Base 280 IRQ 3 RAM base D000 d Boot ROM accept defaults e Network Interface Automatic Media Detection Press lt Alt S gt to save the parameter settings Select OK in the status window The first ethernet board is now configured The same basic steps are repeated to configure the second board Select Previous from the Custom Installation window The EZStart V 5 46 for Ethernet window appears 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software 15 16 17 18 19 20 21 22 23 24 April 1998 Press lt Alt S gt to choose Select Adapter Highlight the second entry second ethernet card in the list and press lt Return gt from the Ethernet Adapter Selection menu The EZStart V 5 46 for Ethernet window appears Press lt Alt C gt to select Custom Setup The Custom Installation window appears Press lt Alt S gt to select Setup The Custom Setup window appears Use the arrow keys to highlight lt Return gt to select and lt Tab gt to move through the fields to set the following parameters a Addressing Mode Memory Mapped b RAM Base D400 c Plug and Play Adapter Feature Disabled d Required Settings I O Base 300 IRQ 5 e Boot ROM accept defaults f Network Interface Automatic Media Detection Press lt Alt S gt to save the parameter settings Se
43. 0 32K Disabled ISA Adapter Shadow C800 16K Disabled ISA Adapter Shadow CC00 16K Disabled ISA Adapter Shadow D000 16K Disabled ISA Adapter Shadow D400 16K Disabled ISA Adapter Shadow D800 16K Disabled ISA Adapter Shadow DCOO 16K Disabled IDE Block Mode Disabled Primary Ctrl 32 Bit Transfer Enabled 166 MHz box Ver R03 Primary Master LBA Mode Disabled Primary Slave LBA Mode Disabled Secondary Cirl Drives Present None Boot to PnP Operating System No 166 MHz box Ver R03 OS2 Above 64 MB Memory Support Disabled 166 MHz box Ver R03 April 1998 6880493G51 A 3 7 Installing the UCC Software WMG Administrator Messaging Switch Software Installation 10 Press lt Esc gt to save the changes and return to the main menu 11 Select Chipset from the main menu and press lt Return gt The Chipset Setup window appears 12 Define the settings see Table 3 3 Table 3 3 Chipset Setup Window Settings Field Setting UCC Version ISA VGA Frame Buffer Size Disabled PCI VGA Palette Snooping Disabled PCI VGA Buffering Disabled On Board PCI SCSI Enabled On Board PCI IDE Disabled 166 MHz box Ver R03 On Board PCI Video Enabled 166 MHz box Ver R03 Boot To PnP operating system No 75 MHz box Ver R02 OS2 Above 64 MB Memory Support Disabled 75 MHz box Ver R02 IRQ5 Available to ISA EISA IRQ9 Available to ISA EISA IRQ10 Available to ISA EISA IRQ11 Available to PCI PnP IRQ12
44. 2 Voice 177 4 77 62 ucc3dci 177 4 77 103 ucc3c UCC 3 optional expansion cabinet Control 177 4 78 103 ucc3v UCC 3 optional expansion cabinet Voice 177 4 77 104 ucc4c UCC 4 optional expansion cabinet Control 177 4 78 104 ucc4v UCC 4 optional expansion cabinet Voice 177 4 77 105 ucc5c UCC 5 optional expansion cabinet Control 177 4 78 105 ucc5v UCC 5 optional expansion cabinet Voice 177 4 77 106 ucc6c UCC 6 optional expansion cabinet Control 177 4 78 106 ucc6v UCC 6 optional expansion cabinet Voice 177 4 77 107 ucc7c UCC 7 optional expansion cabinet Control 177 4 78 107 ucc7v UCC 7 optional expansion cabinet Voice 177 4 77 108 ucc8c UCC 8 optional expansion cabinet Control 177 4 78 108 ucc8v UCC 8 optional expansion cabinet Voice 177 4 77 109 ucc9c UCC 9 optional expansion cabinet Control 177 4 78 109 ucc9c UCC 9 optional expansion cabinet Voice 177 4 77 10 10 ucc10c UCC 10 optional expansion cabinet Control 177 4 78 10 10 ucc10v UCC 10 optional expansion cabinet Voice 177 4 78 21 fs1 File server Voice 177 4 78 22 fs2 File server Voice B 2 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installa IP Addresses and Network Diagram OAP IPNP GW To RFC IPNP WMtp LAN Zyplex Hub port 9 a RFC LAN cp1_rfc 1 Twisted Pair emma mnm m RFC LAN cp2_rfc IP Address 10 4 0 2 IP Address 10 4 0 3 Twisted Pair ir cp2 Ti ee ge IP Address 177 3 77 11 Voice LAN cpiv Twisted Pa
45. 5 8 s s m 3 os 5 a 8 g I ol 5 s 5 s p ke O ol O ao as 9 7 o O g o O ie O _ WI000N0000000000 6 lo GA oL Ao O a L g O Ol o ojo o LUTU ol L o o E oo E3 Oo fy D an ssas ree ink al o an a OF oO O o a a lo ol Blank Panel e o O Ol f i o mo oO of ojo ol Oo z Q p TU LUILIU o ve lo q 6 d lo ol Mt E o q s L o Soi Mm El lo o 0 LC l A o o 5 iilii oi i lo o e Eia T A Mi LI S U 301SRH 127d Figure 1 2 WMG MS Typical Redundant DC Powered Two Cabinet Configuration Without SS7 1 8 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Introduction
46. 7 NCD User Services Terminal Emulator a jE File Options Fonts Cursors Keys Administrator ADMINISTRATION MENU Terminal 1 access Remote System Access PPP change Change login and or admin password gateway Examine modify gateway table host Examine modify host table kill Kill TCP connections on serial line line Terminal configuration organised by line port Terminal configuration organised by port quit Return to connections menu reboot Reboot Server Herver Examine uodify Server parameters stats Examine Server statistics trap Examine modify SNMP Trap parameters CHASE IOLAN v3 5 02 CDi tserv1 Figure 2 16 Administration Menu 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation x Administrator Name IP address Subnet mask Ethernet address Language Identification Lock Password limit CR to initiate SNAP encoding Boot host Boot file Init file MOTD file Installing WMG System Software SERYER CONFIGURATION Terminal 1 e Ctserv1 J 177 4 77 35 J 255 255 255 0 J 00 80 d4 00 9b e6 CEnglish Disabled 5 J Yes Disabled 177 4 77 17 Boot diagnostics Enabled L C usr local wmg config iolan3502 config Debug mode Domain name Name server Host to boot Server image Specify IP address or host name CHASE IOLAN v3 5 02 CDi Figure 2 17 Server Configuration window 20 Enter the following information in the rel
47. 8 WMG Administrator Messaging Switch Software Installation Installing WMG System Software setenv diag switch true lt Return gt Change the diag service parameter by typing the following at the ok prompt For Themis based systems type setenv diag device fastdisk lt Return gt For Ultra based systems type setenv diag device disk lt Return gt For Ultra based systems skip to Step 13 7 10 11 12 13 14 April 1998 At the ok prompt type setenv boot device fastdisk lt Return gt Modify the NVRAM at the ok prompt by typing nvedit lt Return gt At line 0 type the following devalias fastdisk iommu f e0000000 sbus f e0001000 QLGC isp 1 10000 sd 3 0 lt Return gt Press lt Ctl C gt to exit nvedit Store the NVRAM changes type nvstore lt Return gt At the ok prompt type setenv use nvramrc true lt Return gt At the ok prompt type printenv lt Return gt The OMC parameters window displays Verify that the information in the OMC parameters window is correct see Figure 2 5 Repeat this procedure to correct any errors 6880493G51 A 2 13 Installing WMG System Software WMG Administrator Messaging Switch Software Installation NCD User Services Terminal Emulator hel File Options Fonts Cursors Keys lt 0 gt ok setenv ttya mode 9600 8 n 1 s ttya mode 9600 8 n 1 s lt 0 gt ok setenv diag device fastdisk diag device lt 0
48. 880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software Configuring the Ethernet Switch To configure the ethernet switch a terminal server serial port must be connected to the terminal serial port on the ethernet switch This terminal server port was configured in the previous section paragraph Configuring the Terminal Server Use the following procedure to configure the LanPlex 2500 ethernet switch 1 Select Terminals from the NCD User Services window 2 Select New Telnet from the Terminals drop down menu 3 Press lt Setup gt from the Wireless Message Gateway Control Center and select Terminals gt New Telnet The NCD Telnet window appears 4 At the telnet window enter ome lt Return gt for the service 5 Push the power distribution panel switch for Ethernet Switch 1 to ON position 6 Push the Ethernet Switch 1 power switch back side to ON position 7 Verify that the Power LEDs are ON green 8 Login as root and enter motorola or a specified root password 9 From the omc prompt in the NCD window type the following For enet 1 type telnet tserv1 10005 lt Return gt For enet 2 type telnet tserv1 10006 lt Return gt The 5 digit number is the port number in the form of 100xx with xx being the two digit terminal server port number for instance 06 The resulting would be 10006 in this example The port is 10005 for ethernet switch 1 and 10006 fo
49. Administrator Messaging Switch Software Installation Installing the UCC Software 11 12 13 14 Press lt Return gt at the prompt You have not installed any packages Type n for Strong Encryption Supplement The system reboots to complete the update process When the packaging command completes the system is finished Verify that the disk Drive and the CD ROM tray is empty UnixWare 2 1 2 OS Installation is now complete Installing Unixware 2 1 2 OS Patches Follow these steps to upgrade the UnixWare 2 1 2 OS 1 April 1998 Plug in the tape drive and set the SCSI ID to 2 Power on the UCC At the SCO Login Window press lt Alt E gt to get a command line At the root prompt type root lt Return gt At the password prompt type motorola lt Return gt Type init 1 and lt Return gt At the root prompt type root lt Return gt At the password prompt type motorola lt Return gt Insert the 44mm DAT WMG UCC 2 1 1 OS Upgrade and Patches tape part number 0180302F17 6880493G51 A 3 27 Installing the UCC Software WMG Administrator Messaging Switch Software Installation 10 Type tar xvf dev rmt ctape1 lt Return gt 11 Type ed ux2 1 1 and lt Return gt 12 Type addpatch06 lt Return gt 13 Press lt Return gt at the prompts to accept all defaults 14 Type the following to add the remaining patches addpatchxx lt Return gt Where xx is 06 05 07
50. Emergency Recovery menu and press lt Return gt 3 46 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software 16 17 18 19 20 21 22 23 24 25 26 27 April 1998 Once the SCO UnixWare OS reboots press lt Alt E gt to exit the Welcome window At the login prompt type root lt Return gt At the password prompt type motorola lt Return gt Change directories At the UCC prompt type cd ucc_install lt Return gt Execute the following script to configure the system At the UCC prompt type ucc_system_install lt Return gt Type the UCC ID The range of UCCS a system can have is 1 64 For the first UCC type 1 lt Return gt Press lt Return gt to continue At the prompt Configure TELCO boards type N lt Return gt At the prompt Configuring UCC for redundant CPs type Y lt Return gt for a system with redundant CPs N lt Return gt for a system with a single CP At the prompt Configuring UCC for SS7 type N lt Return gt Press lt Return gt to continue At the time zone prompt type Q lt Return gt 6880493G51 A 3 47 Installing the UCC Software WMG Administrator Messaging Switch Software Installation 3 48 28 Type the appropriate time zone and press lt Return gt 29 Press lt Return gt to reboot the UCC 30 Install the UCC system software at this time see pa
51. G51 A April 1998 WMG Administrator Messaging Switch Software Installation Chapter 3 Installing the UCC Software This chapter describes the installation of the Universal Communications Controller UCC software UCC Software Installation Overview 2 Required Tools and Equipment 3 Running the WinBIOS Setup 5 Pentium 166 MHz CPU 5 Pentium 75 MHz CPU 5 Configuring the Ethernet Boards 12 EZStart Keyboard Conventions 12 Procedure 12 Installing UnixWare 2 1 or 2 1 2 16 UnixWare Keyboard Conventions 16 Procedure 17 Installing UnixWare 2 1 1 OS Upgrade 24 Installing UnixWare 2 1 1 OS Patches 25 Installing UnixWare 2 1 2 OS Upgrade 27 Installing Unixware 2 1 2 OS Patches 28 Installing E1 or T1 Dialogic Software 30 Installing the Global Call Development Package 35 Installing the R2 Protocol Disk E1 Option Only 37 Loading Dialogic Patches 38 Loading the UCC System Installation Script 39 Configuring the UCC System 41 Generating the Clone Tape 43 Restoring the UCC System Cloning Tape 46 Hardware Requirements 46 Software Requirements 46 Procedure 46 April 1998 6880493G51 A 3 1 Installing the UCC Software WMG Administrator Messaging Switch Software Installation UCC Software Installation Overview The Motorola factory installs the UCC software Use this procedure to reload software to an existing UCC or to load software to anew UCC The UCC requires the installation and configuration
52. Item gt until ETALR appears on the printer display Press lt Value gt then lt gt until OFF appears on the printer display Press lt Select gt Press lt Item gt until CFG TCP IP appears on the printer display Press lt Value gt then lt gt until YES appears on the printer display Press lt Select gt Press lt Item gt until BOOTP appears on the printer display Press lt Value gt then lt gt until BOOTP NO appears on the printer display Press lt Item gt until BOOTP NO appears on the printer display Press lt Item gt until IP BYTE 1 0 appears on the printer display Press lt Value gt then lt gt until IP BYTE 1 10 appears on the printer display Note Hold down the lt gt button for automatic incrementing or decrementing 30 31 32 33 34 35 April 1998 Press lt Select gt until IP BYTE 1 10 appears on the printer display Press the lt Item gt until IP BYTE 2 0 appears on the printer display Press the lt Value gt then lt gt until IP BYTE 2 5 appears on the printer display Press lt Select gt until IP BYTE 2 5 appears on the printer display Press lt Item gt until IP BYTE 3 0 appears on the printer display Press lt Value gt then lt gt until IP BYTE 3 0 appears on the printer display 6880493G51 A 2 51 Installing WMG System Software WMG Administrator Messaging Switch Software Installation 36 37
53. MS H Messaging Switch Home MS I Messaging Switch Input MS O Messaging Switch Output N1 Nippon trunk level 1 NewsPager NewsPager Corporation of America signaling code NFS Network File Server A 8 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Wireless Messaging System Terminology Table A 2 Telecommunications Terminology Sheet 4 of 6 Name or Acronym Definition NIC Network Interface Controller OMC Operation and Maintenance Center os Operating System PCI Personal Computer Interface Pentium A microprocessor from Intel PIN Personal Identity Number PMU Personal Message Unit pager or radio receiver POCSAG Post Office Code Standardization Advisory Group PSTN Public Switched Telephone Network RAID Redundant Array of Inexpensive Disks RAM Random Access Memory ReFLEX Two Way Asymmetric radio signaling protocol RF Radio Frequency RIC Radio Identity Code RISC Reduced Instruction Set Computer RS 232 Serial interface specification RX Receiver SCSI Small Computer System Interface SDD Software Design Document SLIP Synchronous Line Interface Protocol SNMP Simple Network Management Protocol SPARC Scalable Processor Architecture SRS Software Requirements Document T1 Trunk level 1 U S A TAM Two way Asymmetric April 1998 6880493G51 A A 9 Wireless Messaging System Terminology WMG Ad
54. Mode Manual OnBoard FDC Enabled OnBoard IDE Disabled 75 MHz box Ver R02 Serial Port1 3F8H Serial Port2 Disabled Parallel Port 378H Parallel Port Mode Normal 19 Press lt Esc gt to save the changes and return to the main menu 20 Press lt Esc gt to save the system configuration and exit the setup menu The Exit Setup window appears 21 Select Save Changes and Exit and press lt Return gt The system automatically reboots 22 During the system boot memory test turn off power to the system The WinBIOS Setup is complete 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software Configuring the Ethernet Boards The EZStart utility program configures the ethernet SMC EtherEZ 8416 boards EZStart Keyboard Conventions The EZStart utility program uses the following navigation keys see Table 3 1 Table 3 6 Using EZStart Navigation Keys Key Description lt Enter gt oe Return Press the Enter key to select a highlighted function lt Tab gt Press the Tab key to move to the next field or button lt Shift Tab gt Press Shift Tab keys to move to a previous field or button Press the up or down keys to move the cursor above or below the current Arrow Keys selection lt F1 gt Press the F1 key to obtain help lt Spacebar gt Press the spacebar to display a menu of values for a highlighted item lt Alt underscored Press and h
55. R DOS Bootable disk part 0180302F49 SCO UnixWare Installation disk part 0180302F49 SCO UnixWare Host Bus Adapters disk part 8280520F49 6880493G51 A 3 3 Installing the UCC Software WMG Administrator Messaging Switch Software Installation e Additional Software Note SMC EtherEZ ISA LAN Adapters disk SCO UnixWare Host Bus Adapters Patch disk part 0180302F54 SCO UnixWare 2 1 1 OS upgrades and patches tape part 0180302F17 Dialogic Development Package 4 2 disks part 8280520F39 Antares Developer Base Package Version 2 01 R 3 disk part 820520F40 UnixWare 2 0 SCbus SR 4 2SC disks Global Call part 8280520F48 R2 Protocol part 8280520F43 Dialogic Patches part 01v80302F43 Dialogic ICAPI Call Control Library for Global Call disks UCC R3 1 Install Scripts disk part 0180302F23 SCO UnixWare UCC Clone Install Script disk UnixWare activation key and CD ROM serial number Have the WMG MS release notes available when installing the software in this chapter Software is continually changing and the release notes may contain important information relating to the software or procedures that are covered in this book 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software Running the WinBIOS Setup The main menu of the WinBIOS Setup program divides into the following four windows e Setup e Utility e Security e
56. Return gt config_fs factory lt Return gt 2 Enter the filer server host name by typing fsv lt Return gt 3 Login to the file server by typing telnet fsv lt Return gt 4 Type motorola or a specified root password at the password prompt and press lt Return gt 5 Log into the file server and reconfigure the server using the new setup installed with the config_fs script Type reboot and press lt Return gt at the fsv gt prompt April 1998 6880493G51 A 2 69 Installing WMG System Software WMG Administrator Messaging Switch Software Installation 6 The filer server will close the telnet connection during reboot OMC System Application Installation Use this procedure to install the OMC system application 1 At the omc prompt run the install script by typing install factory lt Return gt Type y and press lt Return gt to specify x terminals for the system Enter the IPs for each x terminal For the first x terminal type omcterm1 lt Return gt For a second x terminal if required type omcterm2 lt Return gt Press lt Return gt to continue Type n and press lt Return gt to reboot later Creating the OMC Database Use the following procedure to create the OMC database 1 2 70 Run the install_after_reboot script to set up the license files and the database and to tape archive symbolic links by typing cd usr local wmg config lt Return gt install_after_reb
57. Software 56 57 58 59 60 61 62 63 65 66 67 68 69 70 71 72 73 74 75 April 1998 Press lt Item gt until LG BYTE 2 appears on the printer display Press lt Value gt then lt gt until 5 appears in the printer display Press lt Select gt Press lt Item gt until LG BYTE 3 appears on the printer display Press lt Value gt then lt gt until 0 appears in the printer display Press lt Select gt Press lt Item gt until LG BYTE 4 appears on the printer display Press lt Value gt then lt gt until 2 appears in the printer display Press lt Select gt Press lt Item gt until GW BYTE 1 appears on the printer display Press lt Value gt then lt gt until 10 appears in the printer display Press lt Select gt Press lt Item gt until GW BYTE 2 appears on the printer display Press lt Value gt then lt gt until 5 appears in the printer display Press lt Select gt Press lt Item gt until GW BYTE 3 appears on the printer display Press lt Value gt then lt gt until 0 appears in the printer display Press lt Select gt Press lt Item gt until GW BYTE 4 appears on the printer display Press lt Value gt then lt gt until 2 appears in the printer display 6880493G51 A 2 53 Installing WMG System Software WMG Administrator Messaging Switch Software Installation 76 77 78 79
58. Solaris ID and system environment ID Informix keycards Report Writer WMG application licenses e WMG MS release notes Software is continually changing and the release notes may contain important information that is not in this book April 1998 6880493G51 A 2 5 Installing WMG System Software WMG Administrator Messaging Switch Software Installation Configuring the X Terminal The x terminal is the display interface for the WMG Control Center The WMG Control Center is a Graphical User Interface GUI for issuing commands setting up system parameters and generating reports The WMG MS x terminal has two configuration environments the NCD windows environment and the NCD Boot Monitor The windows environment is a GUI and the Boot Monitor is menu driven The initial configuration of the x terminal in this procedure occurs in the Boot Monitor Later procedures in the WMG MS configuration occurs through the windows environment Use the following procedures to configure the x terminal 1 Power up the x terminal The NCD windows environment appears 2 Press the following keys at the same time lt Ctrl Left Alt gt and lt Setup gt The Boot Monitor command line prompt appears 3 Load the default values a b c d e Type nv lt Return gt Type L lt Return gt Type S lt Return gt Type Y lt Return gt Type q lt Return gt 4 Press lt Setup gt at the Boot Monitor prompt The Boot Monitor ma
59. System Software WMG Administrator Messaging Switch Software Installation 2 22 NCD User Services Terminal Emulator 2 File Options Fonts Cursors tmp umg_setup Beginning WMG Package Installation for omc at Mon Apr 14 16 05 07 PDT 1997 xex After System reboots Check usr tmp wmg_install log for more information x Installation of INFORMIX products requires a serial number and a key enter serial number and key for the following INFORMIX EMBEDDED SQL Run Time Facility Yersion 7 10 UC1 Copyright C 1984 1994 Informix Software Inc Enter your serial number for example INF X999999 gt AAA HI123546 Enter your serial number KEY uppercase letters only gt ABCDEF INFORMIX OnLine Dynamic Server Yersion 7 10 UC1 Copyright C 1986 1994 Informix Software Inc Enter your serial number for example INF X999999 gt AAA IL23456 Enter your serial number KEY uppercase letters only gt ABCDEF Figure 2 9 Information Installation Script Menu 9 10 Type the Informix OnLine Dynamic Server serial number key uppercase letters only and press lt Return gt Define IP addresses for WMG standard host names Press lt Return gt at each prompt to accept defaults The license type codes Informix and IP addresses for WMG MS standard host names are now defined The WMG installation script formats the disc drive and loads the OMC After all WMG MS software is installed the system reboot
60. WMG Administrator Messaging Switch Series Wireless Messaging System System Version Two Way 3 0 One Way 1 07 Software Version 3 3 7 Software Installation Issue Date April 1998 6880493G51 A MA MOTOROLA WMG Administrator Messaging Switch Series Wireless Messaging System System Version Two Way 3 0 One Way 1 07 Software Version 3 3 7 Software Installation Issue Date April 1998 6880493G51 A AA MOTOROLA WMG Administrator Messaging Switch Software Installation Foreword General Information The information in this manual has been reviewed for accuracy However no responsibility is assumed for inaccuracies Motorola reserves the right to make changes to any products discussed herein The information in this document is subject to change without notice Motorola assumes no liability for hardware or software damage or loss of data because of errors or omissions in this manual Motorola does not assume any liability arising from the application or use of any products or circuits described herein Neither does Motorola convey any license under its patents or right of others Refer questions concerning the contents of this manual or requests for related circuit board information to the following location Motorola Inc Paging Systems Group Multimedia Publications Department 5401 North Beach St MS E230 A Fort Worth TX 76137 2794 or telephone 817 245 2824 To access on line
61. able 3 8 Using UnixWare Navigation Keys Key Description lt Enter gt Press the Enter key to make a selection and continue In windows where you Return must type data in multiple fields lt Return gt moves the cursor to the next field lt F10 gt In windows where you must type data in multiple fields press the F10 key to apply and continue In other windows the F10 key is the same as lt Return gt lt Tab gt Press the Tab key to move to the next field on a window lt Shift Tab gt Press and hold the Shift and Tab keys to move to the previous field Press the left right up and down arrow keys to move the cursor to the left of Arrow Keys right of above or below the current location Press the PgDn key to move to the next page of a window with more than one lt PgDn gt page of data The window footer informs you when a window contains more than one page Press the PgUp key to move to the previous page of a window with more than lt PgUp gt one page of data lt F1 gt Press the F1 key to display help for the current window or menu option lt F2 gt Press the F2 key to display choices if available provided for the current field April 1998 6880493G51 A 3 15 Installing the UCC Software WMG Administrator Messaging Switch Software Installation Note Some UCCs have Seagate ST 3 5 in hard drives These drives require a separate HBA disk supplied by Seagate Installation and hard driv
62. address CCITT Comit Consultatif International T l graphe et T l phone CCS7 Common Channel Signaling System 7 CDR Call Detail Record CEPT Committee of European Post and Telephone CLI Call Line Identity cos Class of Service CP Central Processor CPU Central Processing Unit DCI Digital Channel Interface DID Direct Inward Dialing DOS Disk Operating System DS1 Digital Signal 1 T1 physical DSP Digital Signal Processor DTMF Dual Tone MultiFrequency E1 European trunk level 1 ERMES European Radio Message System FAX Facsimile transmission FS File Server April 1998 6880493G51 A A 7 Wireless Messaging System Terminology WMG Administrator Messaging Switch Software Installation Table A 2 Telecommunications Terminology Sheet 3 of 6 FTP File Transfer Protocol GSC Golay Sequential Code GUI Graphical User Interface ICD Interface Control Document InFLEXion Two way Asymmetric Voice and data radio signaling protocol 1 0 Input Output ICC Intelligent Communications Controller ID Identity IDE Integrated Disk Electronics ISA Industry Standard Architecture for PCs ISDN Integrated Services Digital Network kbps Thousand bits per second LAN Local Area Network MB MegaBytes million bytes MF R1 MultiFrequency Region 1 MFC R2 MultiFrequency Compelled Region 2 MHz MegaHertz MIPS Millions of Instructions Per Second MS Messaging Switch
63. artridge is write protected 3 Verify that the Informix version number for the serial number and the serial number key matches the Informix version in the installation script prompt 4 Insert the installation tape into the 4 mm DAT tape drive of OMC 2 20 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 5 Enter the following UNIX commands at the prompt cd lt Return gt tar xvf dev rmt Olb lt Return gt tmp wmg_setup lt Return gt Note The wmg_setup installation process takes several hours The installation script prompts for the Informix serial number and serial number key see Figure 2 9 Two Informix products Embedded SQL Run Time and OnLine Dynamic Server part number 8280520F25 and 8280520F24 require serial numbers and serial number keys The Informix serial number information comes in a manner similar to the license quantities from the Informix license and key cards Note Verify that in the Informix serial number and the serial number key that are identical to those found on the license cards 6 Type the Informix Embedded SQL Run Time Facility serial number and press lt Return gt 7 Type the Informix Embedded SQL Run Time Facility serial number key uppercase letters only and press lt Return gt 8 Type the Informix OnLine Dynamic Server serial number and press lt Return gt April 1998 6880493G51 A 2 21 Installing WMG
64. arts failing which Motorola shall bill and the Customer shall pay the full current list price of the Advance Replacement Parts 10 To secure payment of the list price of Advance Replacement Parts if the defective items are not returned to Motorola the Customer hereby grants to Motorola a purchase money security interest in any Advance Replacement Parts Revised July 1997 xi Excluded Equipment 11 The following equipment is excluded from this Warranty and is covered instead by the Original Equipment Manufacturer s Warranty a Equipment which is not an integral part of a basic system configuration and which is not manufactured by Motorola such as batteries and satellite dish LNBs b Peripheral equipment such as printers modems data loggers video display terminals and lightning and surge protectors and c Equipment which is not listed in Motorola s Price Book Force Majeure 12 Motorola shall not be responsible for failure to discharge its obligations under this Warranty due to delays by suppliers material shortages strikes lockouts or other labor disputes disturbances government regulations floods lightning fires wars accidents acts of God and any other causes beyond Motorola s reasonable control Default and Termination 13 14 Motorola shall have the right to immediately terminate this Warranty and to suspend its performance under this Warranty upon notification to the Customer if the Cus
65. ct the CD ROM drive using the following procedure April 1998 6880493G51 A 2 23 Installing WMG System Software WMG Administrator Messaging Switch Software Installation Disconnecting the OMC CD ROM Themis Based Systems Disconnect the CD ROM drive using the following procedure 1 Eject the DAT tape and CD ROM disk while using the same NCD terminal emulator window as in the previous installation a Eject the DAT tape by typing the following in the NCD terminal emulator window mt f dev rmt Olb rewoffl lt Return gt a Eject the CD ROM disk by typing the following in the NCD terminal emulator window eject lt Return gt 2 Log out of the OMC by typing exit lt Return gt 3 Wait for the OpenBoot ok prompt 4 Turn off the power to the CD ROM and OMC Power down the CD ROM and the OMC before disconnecting the serial console cable 5 Disconnect the serial console cable 6 Power up the OMC 7 Press lt Setup gt to display the NCD User Services window after the OMC boots 8 Select the Console option 9 Select Reboot in the NCD Console Window The x terminal reboots 2 24 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software Configuring the Terminal Server The terminal server provides the serial connections for the WMG MS subsystem components Specific keys on the keyboard control the navigation through the terminal server u
66. ctions Menu appears press lt Return gt and select CLI and press lt Return gt to get to the local prompt 15 At the local prompt type the following login sequence su lt Return gt iolan lt Return gt 16 At the ADMIN local prompt type the following sequence facreset lt Return gt y lt Return gt Wait for the message System is Shutting Down message 17 Turn off the power to the terminal server 18 Turn on the power to the terminal server 2 26 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 19 At the local login prompt type the command su lt Return gt 20 At the local prompt type the command set term vt100 lt Return gt The Connections menu appears 21 Press lt Return gt from the Connections menu to display the Commands pop up menu 22 Select Admin Mode from the Commands Pop up menu see Figure 2 11 The Administration menu appears 23 Select the password field and press lt Return gt NCD User Services Terminal Emulator File Options Fonts Cursors Keys Name tserv maint CONNECTIONS MENU Terminal 1 Connection Host xxx FREE Commands FREE Telnet xxx FREE Rlogin xx FREE Port idmin mode fl This option allows you to configure parameters affecting the Server box eg hosts table other terminals CHASE IOLAN v3 5 02 CDi tsery1 Figure 2 11 Terminal Server Connection
67. d by a short code Cell A small group of transmitters smaller than a subzone that transmits simultaneously Central Office The telephone switching bureau that supplies the spans to the messaging site usually the PSTN Communicator A device that receives and transmits messages over wireline or radio links see note usually a belt worn device that an individual carries also the PMU PCD or message communicator Coverage Area A collection of Service Areas April 1998 6880493G51 A A 1 Wireless Messaging System Terminology WMG Administrator Messaging Switch Software Installation Table A 1 The Wireless Messaging System Glossary List Sheet 2 of 6 Term Description Deferral A message not sent at the first opportunity but sent at a specified time and date Deregistration Communicator no longer registered on the system Destination The point to which a message is to be sent Direct Messages Messages destined for a Message Communicator as opposed to Mailbox Messages Diversion A message redirected to another destination or subscriber other than that specified by the caller Escalation Group A group in which a message is automatically sent one by one to each member until an acknowledgment is received Event A report of an occurrence within the system Fault A report of an occurrence that indicates that something is not functioning properly Feature Availab
68. d the Informix database software Most of the installation and configuration of the operating system and database is performed using an automated WMG MS installation script The WMG MS uses preset factory default Internet Protocol IP addresses to define the Control LAN Voice LAN OMC LAN and RF Conductor RF C LAN Appendix B lists the default IP addresses host names and configuration drawings to use when installing WMG software To modify system IP addresses use the vi text editor or other editor of your choice consult your network administrator The address values and host names are located on the CP1 CP2 and the OMC in the etc hosts file Note Use the customer s IP plan when makeing changes to the etc hosts file to avoid installation errors The installation of some applications require that the IP address for that host be identified at the time of installation Changing the IP address of that host at a later time may require that the application be reinstalled Following the procedures in this chapter overwrites existing files data and system configuration information Required Tools and Equipment for Themis SPARC 20 based Systems Assemble the following items to perform the software installation procedures for Themis SPARC 20 based systems e External CD ROM drive External or stand alone CD ROM drive configured for use with the Openboot EEPROM SCSI 2 cabling for the external SCSI 2 connection on the back of
69. de Openboot diagnostic messages begin to scroll in the NCD Terminal window 8 When the RAM test and initialization begins press lt Break gt The system responds with an ok prompt April 1998 6880493G51 A 2 11 Installing WMG System Software WMG Administrator Messaging Switch Software Installation Installing the OMC Operating System and Database The WMG installation script performs most of the installation automatically though some configuration information must be entered manually The installation script handles the following tasks e Solaris Formatting the disk drive type Installing the Solaris software Installing Solaris patches e IP address definition e Informix Installing the ESQL run time and Dynamic Server run time tapes There are two phases to the Solaris and Informix installation process e Defining system identification and configuration e Running the OMC installation script Note The OMC installation requires a CD ROM caddy Setting the OMC Open Boot Parameters 1 Reset NVRAM to factory defaults by typing set defaults lt Return gt 2 At the ok prompt reboot the processor board by typing reset lt Return gt 3 During the RAM tests press lt Break gt The system responds with the ok prompt 4 Change the TTYA mode parameter Type the following at the ok prompt setenv ttya mode 9600 8 n 1 s lt Return gt 5 At the ok prompt type 2 12 6880493G51 A April 199
70. e 1 Verify that the 4 mm DAT installation tape provided is the correct part number 0180302F15 and version 2 Insert the installation tape into the 4 mm DAT tape drive of CP1 or CP2 3 Enter the following UNIX commands at the prompt April 1998 6880493G51 A 2 65 Installing WMG System Software WMG Administrator Messaging Switch Software Installation cd lt Return gt tar xvf dev rmt Olb lt Return gt tmp wmg_ setup lt Return gt 4 Define IP addresses for WMG standard host names Accept the IP defaults by pressing lt Return gt at each prompt The system prompts for confirmation Note Consult your network administrator for IP information If your system IP map differs from the WMG standard system IPs modify as necessary The WMG system diagram shows the pre set standard system IPs see Appendix B When the IP addresses for WMG standard host names are defined the WMG MS installation script formats the disc drive and loads the CP1 tape After the WMG MS software installation completes the CP1 board reboots from the disc drive Note The wmg_setup installation process takes approximately three hours The Root Password window appears see Figure 2 28 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software NCD User Services Terminal Emulator File Options Fonts Cursors On this screen you can create a root password A root password
71. e Re Management T network _ gt III I System j Messages to and from subscribers Tas Communicators WMG Administrator 202 01SRH Figure 1 1 The WMG Administrator MS and the Wireless Messaging System WMG MS Subsystems and Peripherals The following subsystems comprise the WMG MS e The Central Processor CP maintains a copy of the subscriber database the Operations and Maintenance Center OMC maintains the master subscriber database messaging and routing functions e The UCC provides the interface of the PSTN to the WMG MS using T1 or E1 trunk spans e The File Server controls the storage of voice and data messages using a Redundant Array of Inexpensive Disks RAID system e The OMC provides an operator interface through a graphical user interface GUI called the Wireless Message Gateway Control Center The WMG MS OMC accesses the Network Management System through the controller 1 6 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Introduction The WMG MS is made up of one or more cabinets depending on redundancy and capacity requirements The third and following cabinets usually contain additional UCC for expanded messaging capacity see Figure 1 2 and Figure 1 3 In a typical redundant system two cabinets house the standard subsystems including
72. e using a fully qualified name if running DNS Please Please Please Please Please Please Please Please Please Please Please enter enter enter enter enter enter enter enter enter enter IP address for Network netmask 255 255 0 0 media type for Network IP address for Network netmask 255 255 0 0 IP address for Network IP address for Network IP address for Network fsv Interface e0 177 4 78 21 255 255 255 0 Interface e0 100tx tp tp Interface ela 177 4 78 22 255 255 255 0 Interface elb Interface elc Interface eid the name of the default gateway The administration host is given root access to the filer s fete files for system administration To allow etc root access to all NFS clients enter RETURN below enter the name of the administration host omcv IP address for omev 177 4 78 17 Please enter timezone US Pacific PRC Now type reboot for changes to take effect Figure 2 19 File Server Setup Menu 12 Enter the host name for the FS by typing fsv lt Return gt 13 Enter the IP address for network Interface e0 by typing 177 4 78 21 lt Return gt 2 44 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software This is the address of the file server voice LAN Note The Setup program provides the names of each interface In the above step network interface e0 14 15 16 17 18
73. e File menu and select the Exit option 58 From the Welcome to Unixware 2 1 menu press lt Alt D gt to select delete welcome 59 Select the following icons in succession Admin_Tools Networking and Dialup_Setup 60 From the Dialup_Setup window select Actions lt Return gt 61 From the Actions menu select Set up Devices Device and New 62 Navigate through the following fields see Table 3 1 and set the following parameters a Port Com1 b Connect to Direct April 1998 6880493G51 A 3 21 Installing the UCC Software WMG Administrator Messaging Switch Software Installation 63 64 65 66 c Configure port as Bidirectional d Speed other 9600NP e Portis Enabled When the parameters are correct select Add and press lt Return gt Return to the UnixWare Desktop by selecting Exit from the various windows From the main menu select Save and Exit lt Return gt Press lt Ctrl Alt Del gt to reboot the UCC If installing UnixWare 2 1 operating system OS then installation is complete 67 Power off during RAM testing UnixWare installation is complete 3 22 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software Installing UnixWare 2 1 1 OS Upgrade If you have installed UnixWare 2 1 2 part number 0180302F49 then install the 2 1 2 OS upgrade and patches outlined in paragraph Installing UnixWare 2 1 2 OS Up
74. e Operator and group security The Wireless Message Gateway Control Center uses UNIX security procedures for password administration and expiration Statistics The Wireless Message Gateway Control Center collects statistics from each WMG MS subsystem CP UCC FS and OMC The Statistics Viewer produces statistical reports The format and content of the reports are configurable Alarms The Wireless Message Gateway Control Center receives and reports alarm conditions Alarm conditions have assigned severity levels Visual indicators alert operators that alarms have been received Alarms are stored in log files for later analysis Configuration The Wireless Message Gateway Control Center provides the capability for managing system configurations operational service status and network and subsystem parameters Subscriber management The Wireless Message Gateway Control Center provides the capability for managing the subscriber database 1 10 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Chapter 2 Installing WMG System Software This chapter describes the WMG Administrator Messaging Switch WMG MS software installation for Version 3 1 WMG MS Software Installation Overview 2 3 Software Used by the WMG MS 2 3 System Software 2 4 Installing the Operating System 2 4 Configuring the X Terminal 2 7 Setting the OMC Serial Connection 2 11 Installing the OMC Operating
75. e Solaris 2 5 1 Hardware CD ROM into the CD ROM drive Type boot cdrom and press lt Return gt at the ok prompt Select the type of terminal in use see Figure 2 24 type 12 if using the X Terminal Emulator and press lt Return gt 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software NCD User Services Terminal Emulator sm File Options Fonts Cursors Keys Hhat type of terminal are you using ANSI Standard CRT DEC T52 DEC T100 Heathkit 19 Lear Siegler ADM31 PC Console Sun Command Tool Sun Horkstation Televideo 910 10 Televideo 925 11 Hyse Model 50 12 X Terminal Emulator xterms 13 Other Type the number of your choice and press Return 12 Figure 2 24 Select Type of Terminal The Solaris Installation Program window appears see Figure 2 25 April 1998 6880493G51 A 2 61 Installing WMG System Software WMG Administrator Messaging Switch Software Installation NCD User Services Terminal Emulator jo File Options Fonts Cursors Keys The Solaris Installation Program You are now interacting with the Solaris installation program The program is divided into a series of short sections ft the end of each section you will see a summary of the choices youve made and be given the opportunity to make changes As you work with the program you will complete one or more of the following tasks 1 Identify peripheral devices
76. e netmask of the subnet a Enter the subnet value in the Netmask field that corresponds to the internet class IP address by typing 255 255 0 0 lt F2 gt The Time Zone Region window appears 14 Specify the default time zone a Use the arrow keys to select the appropriate country value then press lt Return gt b Use the arrow keys to select the appropriate time zone file then press lt Return gt The Date and Time window appears c Enter the appropriate date and time for the selected country The Confirm Information window appears 15 Verify that the information entered on the previous windows is correct 16 Press lt F4 gt to make changes if needed 17 Press lt F2 gt to continue 18 After confirming the information by pressing lt F2 gt the Install Solaris Software Initial window appears see Figure 2 7 Note Wait until the CD ROM finishes reading the CD This takes approximately two minutes 19 Press lt F5 gt to exit Solaris installation and to begin the WMG installation script The Exit Installation window appears see Figure 2 8 20 Press lt F2 gt to exit Solaris installation Note The system saves all information defined until to this point The system displays the prompt The WMG installation script is ready for execution 2 18 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software NCD User Services Terminal Emulator
77. e recognition are not possible without this disk Novell supports Quantum hard drives Procedure Follow these steps to install the UnixWare Personal Edition 2 1 operating system onto the UCC 1 Insert the SCO UnixWare Installation disk Version 2 1 disk into UCC drive A 2 Place the SCO UnixWare Personal Edition Version 2 1 CD ROM into the CD ROM drive part number 0180302F36 or 0180302F49 3 Power up the UCC Note The Unixware window takes approximately 3 minutes to appear Do not enter any key strokes during this time Wait until the ASCII Welcome Banner appears 4 Press lt Return gt after the Welcome to UnixWare 2 1 Installation message displays 5 Select US ASCII for keyboard type and press lt Return gt 6 Type the CD ROM serial number and activation key from Certificate of License and Authenticity The serial number and activation key are case sensitive enter the information exactly as it appears Note The license key for the software and the CD ROM serial number are a matched set The license key and serial number are different for each UCC Use the appropriate license key and serial number for each UCC in systems with more than one UCC 7 Press lt F10 gt to apply The UnixWare 2 1 Installation menu appears with a Choices pop up menu 8 Select Continue Installation lt Return gt 9 Remove the UnixWare 2 1 Installation disk from the UCC disk drive 3 16 6880493G51 A April 1998 WMG Administra
78. ers Dirt or other foreign matter should not be allowed to accumulate in the interior of the enclosure Damage Requiring Service Do not attempt to perform service functions that are not described in the operating instructions All other servicing should be referred to qualified service personnel vi 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Foreword Telephone Line Installation All telephone line connections to the equipment should be accomplished with the telephone lines disconnected from the network interface Motorola is not responsible for static damage to equipment not sold under the Motorola logo Motorola Inc 1999 All rights reserved Printed in the U S A April 1998 6880493G51 A vii Foreword WMG Administrator Messaging Switch Software Installation viii 6880493G51 A April 1998 PSG Limited Equipment Warranty for Non U S and Non Canadian Markets General Terms 1 Motorola Paging Systems Group PSG manufactured infrastructure equipment is warranted to be free from defects in material and workmanship to the original purchaser only as set forth herein This Warranty covers only that equipment identified in paragraph 1 that is used in the manner and for the purpose intended This Warranty specifically excludes any and all software products from any source PSG software products are the subject of the PSG Software Maintenance Program addressed separatel
79. etwork and components units Network Provider The owner and operator of the entire messaging network infrastructure including the gateway RF manager transmitters and receivers sometimes the Network Provider and System Operator are the same entity Network Management System A device that manages and monitors all elements of the messaging system terminal RF manager Tx Rx can provide the means to control operations or optimize the use of resources April 1998 6880493G51 A A 3 Wireless Messaging System Terminology WMG Administrator Messaging Switch Software Installation Table A 1 The Wireless Messaging System Glossary List Sheet 4 of 6 Term Description Notification Message The message generated to the PMU when a message is deposited in a mailbox Operator An individual that interfaces with the gateway to perform configuration messaging or management tasks Originator The individual or computer system that deposits a message or service request into the gateway Outbound message A message sent by the system to the PMU Outlinking A connection to a destination outside the gateway telephone or network that the gateway establishes see Inlinking Pager Type The PMU model including its capabilities Paging Terminal A messaging system accepting message deposits and sending them to their destinations Password An access code for the Subscriber Information Management Mailbox DMS
80. evant fields a Name enter a name for the terminal server that matches the host name of the terminal server type tserv2 b IP address enter the IP address of the terminal server Type 177 4 77 36 c Subnet mask enter the value that corresponds with the IP Type 255 255 255 0 d Ethernet Address Accept default e Language English f Identification leave blank g Lock Disabled h Password limit 5 April 1998 6880493G51 A 2 35 Installing WMG System Software WMG Administrator Messaging Switch Software Installation i CR to initiate Yes j SNAP encoding Disabled k Boot host 177 4 77 17 l Boot file usr local wmg config iolan3502_vbIck16 boot m Init file leave blank n Domain name leave blank o Name server leave blank 21 Press lt Return gt then select Save amp Exit from the Commands Pop up menu 22 Press lt Return gt The Administration menu appears see Figure 2 15 23 Select reboot Reboot Server press lt Return gt then press the spacebar The message Terminal Server Shutdown in progress appears If the reboot is successful the message Image Load Complete appears and the terminal server login prompt is displayed tserv2 gt 24 Disconnect the cable going from Port 1 on the back of the Terminal Server the to NCD serial port This completes the procedure for configuring the terminal server 25 After all the terminal servers are configured close the NCD widow 2 36 6
81. f the menu and the Unix Config Directory a Type usr local wmg config lt Return gt 2 8 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software Note Be certain to enter the trailing slash b Use the arrow keys to highlight the TFTP selection c For TFTP Order use the default of 2 d For NFS Order press D to disable e For MOP Order press D to disable f For LOCAL use the default of 1 14 Use the right arrow key to select Done from the top of the main menu 15 Select Reboot The following prompt appears Save Parameters and reboot Press lt Return gt to confirm 16 Press lt Return gt to save the settings and reboot The x terminal reboots and displays the NCD windows environment window Setting the OMC Serial Connection 1 Connect a serial cable from the NCD x terminal to the OMC console port ttya see Figure 2 2 and Figure 2 3 Serial Port Auxillary F E o o o o o o 9 bq p a 5 5 5 5 5 F Io Te p eld pd pd p q bf Ses SNL O S p qeee Serial Port Figure 2 2 Connecting the NCD X Terminal to the OMC TTYA B Port Themis Systems April 1998 6880493G51 A 2 9 Installing WMG System Software WMG Administrator Messaging Sw
82. fteen 15 working days of receipt of the equipment e Motorola shall at its cost ship the repaired or replaced item to the Customer If the Customer has requested Express Shipping the Customer shall pay Motorola an expedite fee and f Equipment which is repaired or replaced by Motorola shall be free of defects in material and workmanship for the remainder of the original Warranty or for 90 days from the date of repair or replacement whichever is longer All other terms of this Warranty shall apply to such repairs or replacements Advance Replacements 9 During the Warranty Period a At the Customer s request and for the Customer s convenience Motorola may supply the Customer with Advance Replacement Parts parts furnished in advance of Motorola s receipt of defective items Motorola s provision of such parts will be contingent on part availability and on the Customer s maintaining a satisfactory credit standing with Motorola b Motorola shall ship the Advance Replacement Parts requested by the Customer within 48 hours of Motorola determining that such service is appropriate if stock is available at the Motorola service location If stock is not available Motorola will make reasonable efforts to locate and provide it to the Customer within ten 10 working days c The Customer shall return defective items to the Motorola Area Customer Care Center within thirty 30 days from the date of shipment of the Advance Replacement P
83. grade If you have installed UnxiWare 2 1 part number 0180302F36 follow these steps to install the UnixWare 2 1 1 OS upgrade 1 Plug in the DAT tape drive and set the SCSI ID to 2 2 Power up the UCC 3 Press lt AIt E gt at the SCO login to go to the command line 4 At the root prompt type root lt Return gt 5 At the password prompt type motorola lt Return gt 6 Type initi lt Return gt 7 At the root prompt type root lt Return gt 8 At the password prompt type motorola lt Return gt 9 Insert the 44mm DAT WMG UCC 2 1 1 OS Upgrade and Patches tape part number 0180302F17 10 Type tar xvf dev rmt ctape1 lt Return gt 11 Type cd ux2 1 1 lt Return gt 12 Type upgrade211 lt Return gt 13 Press lt Return gt to select all packages April 1998 6880493G51 A 3 23 Installing the UCC Software WMG Administrator Messaging Switch Software Installation 14 Press lt Return gt to continue with installation 15 Select 1 to disable Single UNIX Specification conformance now and press lt Return gt 16 Select 2 to continue with installation and press lt Return gt Note This process takes approximately 15 minutes 17 Select 1 to continue and press lt Return gt 18 Select 3 to skip backup and press lt Return gt 19 Select 2 to continue with the installation Note This process takes approximately 30 minutes 20 Remove the tape and press lt Return gt
84. gt ok nvedit fastdisk 0 devalias fastdisk iommu f c0000000 sbus F e0001000 QLGC isp 1 10000 sd 3 0 1 lt 0 gt ok nvstore lt 0 gt ok setenv use nvramrc true use nvramrc true lt 0 gt ok setenv tpe link test true tpe link test lt 0 gt ok printenv Parameter Name tpe link test output device input device keyboard click keymap ttyb rts dtr of F ttyb ignore cd ttya rts dtr of F ttya ignore cd ttyb mode ttya mode fcode debug local mac address screen columns screen rows selftest megs scsi initiator id sbus probe list auto boot watchdog reboot diag file diag device boot file boot device silent mode use nvramrc nvramrc sunmon compat security mode security password true Yalue true screen keyboard false false true false true true false fastdisk fastdisk false true devalias fastdisk iommu false none Figure 2 5 Openboot Parameters for OMC 2 14 6880493G51 A Default Yalue true screen keyboard false false true false true 9600 8 n 1 9600 8 n 1 false false 80 34 1 7 fe0123 true false net disk net false false false none April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 15 Reboot the system at the ok prompt type reset lt Return gt 16 Press lt Break gt during the RAM tests The system responds with the ok prompt
85. he HBA Drivers 2 1 disk when the prompt appears and press lt Return gt Note Ifthe UCC prompts for CBxx HBA disk then use part number 0180302F54 otherwise use 0180302F36 or 0180302F49 29 When the UnixWare Installation prompt appears remove the HBA Drivers 2 1 disk and the CD ROM and press lt Return gt to reboot 30 From the Network Interface Card Selection Support Utility Summary window select Add an Entry for a card and press lt Return gt 3 18 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software 31 32 33 34 35 36 37 38 39 40 41 April 1998 Press lt PgDn gt to select SMC_EtherEZ_Ethernet_8416 and press lt Return gt From the Configuring SMC_EtherEZ_Ethernet_8416 pop up menu use the lt F2 gt key to select the following options for card 1 a IRQ 3 b I O Address 280 29F c Memory D0000 D3FFF Press lt F10 gt to apply Select Add an Entry for a card and press lt Return gt Press lt PgDn gt to select SMC_EtherEZ_Ethernet_8416 From the Configuring SMC 8416 pop up menu type the following options for card 2 a IRQ 5 lt F2 gt b I O Address 300 31F lt F2 gt C Memory D4000 D7FFF lt F2 gt Press lt F10 gt to apply The Configuration Information for cards 1 and 2 appears Select Accept All Entries and press lt Return gt Respond Yes to the Are You Sure pop up prompt The s
86. he prompt Y for a single rebuild and N for individual package rebuilds yn type Y lt Return gt 6880493G51 A 3 29 Installing the UCC Software WMG Administrator Messaging Switch Software Installation 13 Select the following modules for installation by pressing Y lt Return gt at the prompt D 42 Development Package n DMX Demonstration Package n FAX Development Package n NETWORK Development Package n TTS Development Package n VR Development Package n Voice Demonstration Package n Voice Development Package n 14 At the prompt type Y to verify that the following modules are selected for installation NETWORK Development Package Voice Development Package 15 Have the Dialogic board configuration information ready before continuing 16 At the prompt Do you wish to continue with installation yn type Y lt Return gt 17 At the following prompts press lt Return gt to accept the default values that are listed in parenthesis or type the values provided and press lt Return gt Enter the number of MSI boards in the system 0 lt Return gt Enter the number of DMX boards in the system 0 lt Return gt Enter the number of DTI 211 boards in the system 0 lt Return gt Enter the number of DTI 212 boards in the system 0 lt Return gt Enter the number of DTI 1xx boards in the system 0 lt Return gt Enter the number of HD
87. in menu appears see Figure 2 1 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software Keyboard Monitor Network Help Use the arrow keys to navigate through the menus listed across the top of the screen Left Right Go to previous or next menu Up Down Go to previous or next field within the current menu Control U Delete to beginning of line Escape Restore previous value Help for each field within a menu is shown along the bottom of the screen Exit via the Done menu at the right of the screen 301SRH 53 Figure 2 1 Boot Monitor Main Menu The main menu displays the names of the six menus To move from one menu item to the next use the left and right arrow keys As you navigate through the menu bar the active menu name highlights and the corresponding window displays Below the window a smaller help window displays instructions 5 Use the right arrow key to select Keyboard The window displays available keyboard settings 6 Select IBMPS 2 if your keyboard is the N 101 MPS type otherwise select n 101 See the label on the bottom of the keyboard for information 7 Press the arrow keys to select Monitor The Monitor window displays the available settings 8 Select the appropriate setting 1280 x 1024 70 Hz color for the NCD HMX model and press the right arrow key April 1998 6880493G51 A 2 7 Installing WMG System Software WMG Administrat
88. in window press lt Alt E gt to exit 2 Login as the root user At the root prompt type root lt Return gt April 1998 6880493G51 A 3 45 Installing the UCC Software WMG Administrator Messaging Switch Software Installation 3 At the password prompt type motorola lt Return gt 4 Remove the UnixWare software by executing fdisk to delete the partition Log in the UCC as a root user and type UCC gt fdisk Return gt UCC gt 3 lt Return gt Delete a partition UCC gt 1 lt Return gt Partition to delete UCC gt Y Yes lt Return gt UCC gt 4 Exit lt Return gt 5 Power down the UCC 6 Insert SCO UnixWare Emergency Backup Disk 1 into the floppy disk drive 7 Connect the tape unit with the SCSI ID set to 2 8 Power up the UCC 9 When asked for the second Backup Disk remove Emergency Backup Disk 1 and insert Emergency Backup Disk 2 into floppy disk drive and press lt Return gt 10 At the window the hard disk is NOT sane press lt Return gt 11 Select Restore Disk s from the Emergency Recovery Menu and press lt Return gt 12 Insert SCO UnixWare Emergency Backup Tape into the tape drive and press lt Return gt Note This procedure may take 45 60 minutes to complete 13 At the window Disk s is are successfully restored press lt Return gt 14 Remove SCO UnixWare Emergency Backup Disk 2 and remove the DAT tape drive cable 15 Choose Reboot from the
89. ing systems The classrooms at Motorola are equipped to ensure hands on experience in practical lab exercises Training courses range from a basic introduction to communicators and messaging systems to customized classes on specific systems and large system applications To obtain a course catalog or scheduling information please call 817 245 2184 or 800 724 3588 and ask for the training coordinator Computer Software Copyrights The Motorola products described in this manual might include copyrighted Motorola computer software stored in semiconductor memories and other media Laws in the United States and other countries preserve for Motorola certain exclusive rights for copyrighted computer programs including the exclusive right to copy or reproduce in any form the copyrighted computer software Accordingly any copyrighted Motorola computer software contained in the Motorola products described in this manual cannot be copied or reproduced in any manner without the express written permission of Motorola iv 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Foreword Furthermore the purchase of Motorola products does not grant either directly or by implication estoppel or otherwise any license under the copyrights patents or patent applications of Motorola except for the normal nonexclusive royalty free license to use that arises by operation of law in the sale of a product Trademarks
90. inter display Note Hold down the lt gt button for automatic incrementing 20 Press lt Return gt until IP BYTE 1 10 appears on the printer display 21 Press lt Item gt until IP BYTE 2 0 appears on the printer display 22 Press lt gt until IP BYTE 2 5 appears on the printer display Note Hold down the lt gt button for automatic incrementing 23 Press lt Return gt until IP BYTE 2 5 appears on the printer display 24 Press lt Item gt until IP BYTE 3 0 appears on the printer display 25 Press lt gt until IP BYTE 3 0 appears on the printer display Note Hold down the lt gt button for automatic incrementing 26 Press lt Return gt until IP BYTE 3 0 appears on the printer display 27 Press lt Item gt until IP BYTE 4 0 appears on the printer display 28 Press lt gt until IP BYTE 4 50 appears on the printer display Note Hold down the lt gt button for automatic incrementing 29 Press lt Return gt until IP BYTE 4 50 appears on the printer display 30 Press lt On Line gt to place the printer in the on line mode April 1998 6880493G51 A 2 49 Installing WMG System Software WMG Administrator Messaging Switch Software Installation Local printer set up is complete for HP 4MP Setting up the HP 5M Use the printer control panel to perform the following configuration procedure for the HP 5M printer 1 Verify that that the printer has paper No
91. ir Me Media P i Sea AOT Twisted Pair qe 0 Voice LAN cp2v IP Address 177 4 78 10 Conxsier ie aes e IP Address 177 4 78 11 Control LAN cpic Twisted Pair Me Media Twisted Pair X Control LAN cp2c IP Address 177 4 77 10 U7 77 UT UT MOIener PF Bg pT TTT ttt IP Address 177 4 77 11 Control LAN cptdec 10Base2 10Base2 Control LAN cp2dcc IP Address 177 7 77 12 IP Address 177 7 77 13 cpi IP Address 177 3 77 10 ENET Switch 10Base2 Master Backup IP Address 177 4 77 30 IP Address 177 4 77 31 NO ese 10Base2 10Base2 Converter Converter ucc1dci UCC1C 23 l IP Address 177 4 77 61 Twisted Pair 1 Twisted Pair Control LAN ucc1c File Server IP Address 177 4 77 101 Voice LAN 10Base2 Voice LAN ucc1 IP Address 177 4 78 21 fs1 IPAddress 177 4 70 401 IP Address 177 4 78 22 fs2 10Base2 Control LAN ucc2c IP Address 177 4 77 102 10Base2 Voice LAN ucc2v RS232 10Base2 IP Address 177 4 78 102 RS232 uce3dci UCC3C Terminal Server i He Adress 1174762 IP Address 177 4 77 35 RS232 Control LAN ucc3c 7 IP Address 177 4 77 103 a __ Alarm Panel Voice LAN ucc3v RS232 IP Address 177 4 78 103 RS232 Control LAN ucc4c IP Address 177 4 77 104 Voice LAN ucc4v IP Address 177 4 78 104 Control LAN ucc5c 1e 0 IP Address 10 5 0 2 omc qe 1 IP Address 177 4 77 105 Saphenous i Voice LAN ucc5v i IP Address 177 4 77 17 IP Address 177 4 78 105 eet B7 oice omcv i IP Address 177 4 78 17 1 Twisted Pa
92. ir qe 0 Twisted Pair Media Media Converter Conygrter 10Base2 10Base2 Media Converter B5 Figure B 1 Themis Based Systems Network Diagram To Xterm Printer and OAP To RFC POMC Control LAN Xyplex Hub port 6 1998 IP Addresses and Network Diagram WMG Administrator Messaging Switch Software Installation B 4 6880493G51 A April 1998 MOTOROLA 1999 Motorola Inc
93. is as follows Left LED Active is OFF this will ON green when there is CPU activity Middle LED STDBY SERV is OFF Note if ON yellow this is a problem Right LED Power is ON green 8 Attheprompt Selection 1 5 type 4 lt Return gt to install new file system 9 At the prompt Zero disks and install a new file system type y lt Return gt 10 At the prompt This will erase all data on the disks are you sure type y lt Return gt 11 At the prompt hot spare type no lt Return gt April 1998 6880493G51 A 2 43 Installing WMG System Software WMG Administrator Messaging Switch Software Installation The file server responds with a list of setup prompts requesting configuration information see Figure 2 19 File Options Fonts Cursors Keys fsv gt setup NetApp Release 3 1 4d Mon Aug 26 18 18 33 PDT 1996 System ID 0016782275 slot slot slot slot slot slot 0 System Board Memory Size 0 SCSI Host Adapter 0 3 Disks 0 Ethernet Controller MAC Address 64 MB 11 7GB e0 00 a0 98 00 05 be Twisted pair Quad Ethernet Controller ela MAC Address elb MAC Address elc MAC Address eld MAC Address NVRAM Memory Size 00 c0 95 0 2b 96 Twisted pair 00 c0 95 0 2b 97 Twisted pair 00 c0 95 0 2b 98 Twisted pair 00 c0 95 0 2b 99 Twisted pair 2 MB Dual SCSI Host Adapter SCSI Host Adapter 9a SCSI Host Adapter 9b Please enter the new hostnam
94. itch Software Installation Serial Port Auxillary gt oO gt ae E 351SRH 01 Figure 2 3 Connecting the NCD X terminal to the OMC console Port Ultra Based Systems 2 Select the NCD Window Manager from the NCD window by selecting WindowMgr gt NCD Window Manager The NCD User Services Console window appears see Figure 2 4 3 Select Terminals From the NCD User Services window The NCD User Services Terminal Emulator window appears 2 10 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software NCD User Services Console am Console Login Terminals WindowMgr Utilities Setup Statistics Messages New Terminal New 3270 Keymap Editor New Telnet New Serial EC New Dialer Figure 2 4 NCD User Services Console Window 4 Select serial port The connecting to serial port 1 success message displays 5 From the Serial window select Fonts then select Jumbo 6 Push the power distribution panel switch for the OMC to ON position 7 Turn the OMC power switch on For Themis based systems the power switch is on the front side For Ultra based systems the power switch is on the back si
95. itch is ON green 4 From the local prompt type su lt Return gt 2 32 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software Note Ifthe Connections Menu appears press lt Return gt select CLI then press lt Return gt to get to 10 11 12 13 14 15 16 17 18 April 1998 the local prompt At the local prompt type su lt Return gt iolan lt Return gt At the ADMIN local prompt type facreset lt Return gt Type y to continue Wait for the message System is Shutting Down Turn off the power to the terminal server Turn on the power to the terminal server At the local login prompt type su lt Return gt At the local prompt type set term vt100 lt Return gt The Connections menu appears see Figure 2 11 From the Connections menu press lt Return gt to display the Commands pop up menu Select Admin Mode from the Commands pop up menu The Administration menu appears Select the password field and press lt Return gt Type the password iolan press lt Return gt The Administration menu displays with additional fields see Figure 2 16 From the Administration Menu select server Examine modify Server parameters 6880493G51 A 2 33 Installing WMG System Software WMG Administrator Messaging Switch Software Installation 2 34 19 The Server Configuration window appears see Figure 2 1
96. le A feature available for use by subscriber Feature Denied A feature programmed for operation but not yet functioning for a subscriber Feature Inactive A feature no longer functioning for the subscriber Feature Invoked The feature used by the system to process a call or message for the subscriber Feature Unavailable A feature not longer available for use by the subscriber Feature Undefined A feature no longer programmed with the parameters necessary for operation Gateway The messaging terminal WMG Graphical User Interface GUI The operator interface provided by the system with user friendly graphical images Group A system defined collection of subscribers for which one message is destined Inbound message A message sent by a communicator to the system Information Service Address The Radio Channel Address used to send a message to a group of communicators simultaneously Information Service Provider A registered message originator that can also manage a set of subscribers A 2 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Wireless Messaging System Terminology Table A 1 The Wireless Messaging System Glossary List Sheet 3 of 6 Term Description Inlinking A connection from a destination outside the WMG telephone or network that the WMG allows to be established see Outlinking Legitimization Code A code
97. lect OK in the status window From the Custom Installation window select Previous The EZStart V 5 46 for Ethernet window appears Press lt Alt S gt for Select Adapter Verify that the settings see Table 3 7 6880493G51 A 3 13 Installing the UCC Software 3 14 Table 3 7 Ethernet Board Settings Board Number 1 O Base IRQ RAM Window ROM Window 1 280 3 D000 D1FF None 2 300 5 D400 D5FF None 25 Press lt Alt X gt to exit Note Disregard the disk error message cannot load the file AANCOMMAND COM 26 Turn the system power off and eject the disk Configuration is complete for the SMC EtherEZ 8416 ethernet boards 6880493G51 A WMG Administrator Messaging Switch Software Installation April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software Installing UnixWare 2 1 or 2 1 2 UnixWare provides the operating system for the UCC Before installing this software connect an external CD ROM drive to the SCSI port 1 Connect an external CD ROM drive to the SCSI port on the back of the UCC 2 Set the SCSI ID for the CD ROM drive to 1 UnixWare Keyboard Conventions The UnixWare installation uses function keys for navigation see Table 3 1 Each key does not apply to every window Some windows use additional function keys for window specific options The status line at the bottom of the window indicates when these keys are active and the available options T
98. less the printer has paper in the paper tray 2 Turn the printer power distribution switch ON 3 Turn the printer ON 4 Press lt On Line gt on the front control panel to set the printer to off line 5 Press lt Menu gt until MIO MENU appears on the printer display 6 Press lt Item gt until CFG NETWORK NO appears on the printer display 7 Press lt gt until CFG NETWORK YES appears on the printer display 8 Press lt Return gt until CFG NETWORK YES appears on the printer display 9 Press lt Item gt until TCP IP OFF appears on the printer display 10 Press lt gt until TCP IP ON appears on the printer display 11 Press lt Return gt until TCP IP ON appears on the printer display 12 Press the lt Item gt until CFG TCP IP NO appears on the printer display 13 Press lt gt until CFG TCP IP YES appears on the printer display 14 Press lt Return gt until CFG TCP IP YES appears on the printer display 2 48 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 15 Press lt Item gt until BOOTP YES appears on the printer display 16 Press lt gt until BOOTP NO appears on the printer display 17 Press lt Return gt until BOOTP NO appears on the printer display 18 Press lt Item gt until IP BYTE 1 0 appears on the printer display 19 Press lt gt until IP BYTE 1 10 appears on the pr
99. m Software SERYER CONFIGURATION Terminal 1 e Ctserv1 J 177 4 77 35 J 255 255 255 0 J 00 80 d4 00 9b e6 CEnglish C Disabled 5 J Yes Disabled 177 4 77 17 Boot diagnostics Enabled L C usr local wmg config iolan3502 config Debug mode NS Port 53 Host to boot Server image Specify IP address or host name CHASE IOLAN v3 5 02 CDi Figure 2 13 Server Configuration Window for Version 3 5 02 April 1998 6880493G51 A 2 29 Installing WMG System Software File Administrator SERYER CONFIGURATION REMOTE ADMIN e NCD User Services Terminal Emulator Options Fonts Cursors Keys Name Ctserv1 J Debug mode CO IP address 177 4 77 35 Subnet mask 255 255 255 0 Ethernet address 00 80 d4 00 d7 79 Ethernet interface AUTO J Language English 1 Identification J Lock Disabled Password limit 5 J CR to initiate Yes SNAP encoding Disabled Boot host 177 4 77 17 Boot diagnostics Enabled Boot file C usr local wmg config iolan40019 boot Init file C usr local umg config iolan40019 config J Domain name J Name server NS Port 53 Name of file on host to boot on power up IOLAN RACK v4 00 19 a CDi tserv1 Figure 2 14 Server Configuration Window for Version 4 00 19 26 Define the following parameters in the Server Configuration window a aa 0 oa n ma Pp 9 jio 2 30 Name enter a name for the terminal server that matches the host
100. ministrator Messaging Switch Software Installation Table A 2 Telecommunications Terminology Sheet 5 of 6 TAP Telocator Alpha Protocol TCP IP Transmission Control Protocol Internet Protocol TDP Telocator Data Protocol TIPP Telocator Internetworking Paging Protocol TIS Telocator Inter Switch paging application protocol TME Telocator Message Entry TNPP Telocator Network Paging Protocol TouchTone DTMF TSI Time Slot Interchange TX Transmitter UAP Universal Applications Processor UCC Universal Communications Controller UNIX A computer operating system UTC Universal Time Coordinated V 21 Modem line specification 300 bps V 22 Modem line specification 2400 bps V 27 Fax line specification 4800 bps V 29 Fax line specification 9600 bps V 32 Modem line specification 9600 bps V 42 Modem line specification 19 200 bps Vac Volts AC Vdc Volts DC VMEbus Versa Module Europa Windows Microsoft Windows system for PCs WMG Motorola s Wireless Message Gateway A 10 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Wireless Messaging System Terminology Table A 2 Telecommunications Terminology Sheet 6 of 6 Name or Acronym Definition WMtp Wireless Messaging transfer protocol X 25 Packet switching standard CCITT X 400 Message handling system standard CCITT April 1998 6880493G51 A A 11
101. n to the system Reverse Channel Address The identification used by the PMU when sending an inbound message to the system ResponseList List of canned texts that a PMU uses to respond to outbound messages RF Channel The radio frequency channel used by the PMU RF manager The transmitter network controller RF Conductor Roaming Area A Coverage Area in which the message can be temporarily sent to a PMU Scripting The operator s ability to customize the call or command flow for some functions of the gateway Sender ID A code that identifies the caller Service Area An area in which the message will be sent specifying the RF manager ID RF Channel and Zone Service Provider The individual or business entity that sells operates and maintains the messaging functions for the public the system operator sells or leases time and resources to this entity Signaling Scheme The radio protocol used to communicate with the PMU Span A group of telephone trunk lines Speech to Text The conversion of voice into a numeric message alphanumeric massage or a command Subchannel The splitting of one RF Channel into subchannels that are used for independent radio traffic Subscriber The individual who is the registered person for a Message Communicator or PMU Subscriber Active The system accepts and transmits messages for the subscriber Subscriber COS A set of characteristics that are shared by subscriber
102. nstallpkg lt Return gt Type F to install from the floppy disk Press lt Return gt to continue An installation in progress message appears Eject the Dialogic ICAPI Call Control Library disk 1 of 2 and insert the Dialogic ICAPI Call Control Library disk 8280520F44 2 of 2 Press lt Return gt to continue Press lt Return gt to continue At the prompt Do you wish to install the library type y and press lt Return gt Press lt Return gt to continue Press lt Return gt A message appears stating that installation is complete Remove the ICAPI Call Control Library disk 2 of 2 Installation of the Global Call Development Package is complete April 1998 6880493G51 A 3 35 Installing the UCC Software WMG Administrator Messaging Switch Software Installation Installing the R2 Protocol Disk E1 Option Only Install the R2 protocol as follows 1 10 11 12 13 14 Insert the R2 protocol disk part number 8280520F43 in the UCC floppy drive Type installpkg lt Return gt Type F to install from the floppy disk Press lt Return gt to begin installation Press lt Return gt to continue At the prompt Edit Inbound Call Support protocol file s type n lt Return gt At the prompt Edit Outbound Call Support protocol file s type n lt Return gt Press lt Return gt to continue At the prompt Do you wish to continue type y lt Return gt At the prompt Continue Installation
103. ntinue The Name Service window appears Provide name service information by using the arrow keys to select None for the name service then press lt Return gt to mark the selection Press lt F2 gt The Name Service Confirmation window appears Press lt F2 gt to continue The Subnets window appears Specify that the system is part of a subnet by using the arrow keys to select Yes and press lt Return gt Press lt F2 gt to continue The Netmask window appears Accept the default of 255 255 255 0 for the netmask Press lt F2 gt to continue The Time Zone Regions window appears Verify that the information entered on the previous windows If the information is correct press lt F2 gt Specify the default time zone by using the arrow keys to select the Other Specify time zone file and press lt Return gt Select the appropriate file name and press lt Return gt Enter the international time for the selected country Press lt F2 gt The Confirm Information window appears 6880493G51 A 2 63 Installing WMG System Software WMG Administrator Messaging Switch Software Installation 2 64 19 Verify that the information entered in the previous windows If the information is correct press lt F2 gt to continue Press lt F4 gt to make changes The Install Solaris Software window appears see Figure 2 26 NCD User Services Terminal Emulator File Options Fonts Cursors Install Solaris S
104. oftware Initial The screens that follow let you tailor how Solaris is installed on your system The main tasks you must perform to install Solaris software on your system are Selecting a system type Selecting Solaris software Selecting disks to hold the software youve selected Specifying how files systems are laid out on the disks After completing these tasks a summary of your selections called a profile is displayed You can go back and change selections as many times as you like before starting to install Solaris gt To continue press F2 i F2_Continue F3_Go Back F5_Exit F6_Help Figure 2 26 Install Solaris Software 20 Press lt F5 gt to exit the Solaris Installation The Exit Installation window appears see Figure 2 27 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software NCD User Services Terminal Emulator hall If you exit the Solaris installation program all selections youve made on screens will be deleted However you can restart the Solaris installation program from a UNIX shell gt To exit the Solaris installation program press F2 gt To cancel the exit press F5 F2_Exit Installation F5_Cancel Figure 2 27 Exit Solaris Installation Window 21 Press lt F2 gt to exit Solaris installation The system saves all information defined to this point and displays the prompt Loading the CP1 Installation Tap
105. old the Alt key and underscored character to select a function that is character gt not highlighted For example use lt Alt x gt to Exit lt F3 gt lt F4 gt Press F3 or F4 keys to close the current window Procedure Follow these steps to configure the ethernet boards 1 Insert the DR DOS bootable disk Release 6 0 into the UCC floppy drive 2 Power up the UCC 3 After the boot up memory check verify that the system detects both the hard drive and CD ROM drive The hard drive is SCSI ID 00 and the CD ROM is SCSI ID 01 4 Set the date and time and press lt Return gt April 1998 6880493G51 A 3 11 Installing the UCC Software WMG Administrator Messaging Switch Software Installation 10 11 12 13 14 3 12 Remove the DR DOS disk and insert the SMC EZStart SuperDisk version 2 4 Setup disk 1 of 1 Type ezstart lt Return gt The EZStart Ethernet Adapter Selection menu appears If a license menu appears type lt Alt Y gt to accept the licensing agreement Select the first entry first ethernet card in the list by pressing lt Return gt or lt Alt S gt The EZStart V 5 46 for Ethernet window appears Press lt Alt C gt to select Custom Setup The Custom Installation window appears Press lt Alt S gt to select Setup The Custom Setup window appears Navigate through the fields to set the following parameters see Table 3 1 a Addressing Mode Memory Mapped b RAM Base D00
106. on explains how to identify E1 or T1 or UAP boards The system has E1 boards if one of the following options are on the vend ticket YS69AD or Y569AE The system has T1 boards if vend ticket is YS69AF 13 Type E1 or T1 lt Return gt 14 Enter the number of voice channels use 24 channels for each T1 installed and use 30 channels for each E1 installed According to the type of channel in your system multiply the number of channels for a single board 24 or 30 by the total number of boards and enter the value lt Total number of channels gt lt Return gt 2 74 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 15 Type n lt Return gt at the prompt Does this UCC support SS7 16 Select a TELCO configuration a If the channel type is E1 type r2_8_nop lt Return gt b If the channel type is T1 type dtmf_7_wink_pre and type 1 lt Return gt to input the prepend digit 17 Press lt Return gt for no area code 18 Press lt Return gt for no area name 19 Press lt Return gt to continue The system displays the message uccxx Application Installation was successful 20 Press lt Return gt to reboot the UCC 21 Repeat ucc_app_install for all UCCs in the system This concludes the WMG MS software installation April 1998 6880493G51 A 2 75 Installing WMG System Software WMG Administrator Messaging Switch Software Installation 2 76 6880493
107. oot factory lt Return gt Type yes and press lt Return gt to set up WMG licenses Enter the appropriate licenses as indicated on the vend ticket Type y and press lt Return gt to run db initialization Confirm the db initialization 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 10 11 12 13 At the prompt Load WMG database press lt Return gt At the prompt Please mount tape 1 on usr informix archive_tape_dev press lt Return gt The system displays end of install_after_reboot messages At the prompt System must be rebooted reboot now press lt Return gt Wait until OMC reboots In the application x login window login as root and enter motorola as password From the WMG application menu do the following a Select System b Select Text Editor c Select edit WMG ini d Select Search and look for Pipes e At the end of the line press lt Return gt Type Pipe 1000 IPNPTEST1234 rfc_ipnp Select Save and Exit CP1 or CP2 System Application Installation 1 April 1998 Select Administration from the WMG Application window Type telnet cp1c and press lt Return gt Type root for the login name and press lt Return gt to login to CP1 Type motorola or a specified root password and press lt Return gt Run the install script by typing cd usr local wmg config lt Return gt install factory lt Return gt
108. or Messaging Switch Software Installation The Dots Per Inch pop up menu appears 9 Change the dots per inch setting to 100 10 Press the right arrow key to select Network The Network window displays the current network settings 11 Press spacebar until NVRAM selection is highlighted 12 Configure the network settings as follows a Enter the terminal omcterm1 or omcterm2 IP address Type 10 5 0 16 if this NCD is omcterm1 Type 10 5 0 17 for omcterm2 b Enter the first boot host IP address type 10 5 0 2 c Use the default value of 0 0 0 0 for the second boot host IP address type 0 0 0 0 d Use the default value of 0 0 0 0 for the third boot host IP address type 0 0 0 0 e Enter the gateway IP address type 0 0 0 0 f Make the subnet mask a C class IP type 255 255 0 0 g Enter the broadcast IP address type 10 5 255 255 h Use the default for the Terminal NCDnet address type 0 0 jis Use the default for the Host NCDnet Address type 0 0 Use the default for the Router NCDnet Address type 0 0 k Press the spacebar until No for SNAP 802 2 Encapsulation is highlighted ALL IP addresses used in this manual are the factory default values and are not suitable for use as the customer specific IP addresses needed to configure the WMG MS system You must have the customer IP address plan to continue the configuration and installation process 13 Use the right arrow key to select Boot from the top o
109. owMgr gt NCD Window Manager The NCD User Services Console window appears see Figure 2 23 NCD User Services Console aE Console Login Terminals WindowMgr Utilities Setup Statistics Messages New Terminal New 3270 Keymap Editor New Telnet New Serial New Dialer Figure 2 23 NCD User Services Console Window 3 Select Terminals gt New Serial from the NCD User Services window The NCD User Services Terminal Emulator window appears Select serial port The message connecting to serial port 1 success displays From the Serial window select Fonts then select Jumbo Turn the power on at the PDP and at the CP Openboot diagnostic messages begin to scroll in the NCD Terminal window When the RAM test initialization begins press the lt Break gt key The system responds with an ok prompt Reset NVRAM to factory defaults type set defaults lt Return gt 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 9 Reboot the processor type reset lt Return gt 10 During the RAM tests press lt Break gt The system responds with the ok prompt Setting the Open Boot Parameters 1 Change the ttya mode parameter From the ok prompt type setenv ttya mode 9600 8 n 1 s lt Return gt 2 Change the diag service parameter From the ok prompt type setenv diag device disk lt Return gt 3 From the
110. r ethernet switch 2 The ethernet switch responds with a prompt for access level and password 10 Type adm at the prompt and press lt Return gt April 1998 6880493G51 A 2 37 Installing WMG System Software WMG Administrator Messaging Switch Software Installation 11 Press lt Return gt at the password prompt The Administrative Console menu appears Note For help using the Administrative Console enter a question mark Setting the Ethernet Switch System Level Parameters 2 38 Use this procedure to set the ethernet switch system level parameters 1 10 At the Administrative Console type sys and press lt Return gt The System menu appears At the System menu type nvD and press lt Return gt The System nvData window appears At the System nvData window type reset and press lt Return gt Type Y lt Return gt to continue The ethernet switch will reboot At the prompt type adm and press lt Return gt At the password prompt press lt Return gt The Administrative Console top level menu appears At the prompt Select a menu option type sys and press lt Return gt The System menu appears At the prompt Select menu option system type tim and press lt Return gt The system displays the current date and time Type Y and press lt Return gt to change the time Enter a new date and time 12hr format if necessary using the default format of mm dd yy and hh mm s
111. ragraph UCC Software Installation Overview or the README ucc file found on the release tapes Installation of UCC cloning tape is complete This process completes the entire UCC installation 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Appendix A Wireless Messaging System Terminology This chapter contains two tables Table A 1 and Table A 2 Table A 1 The Wireless Messaging System Glossary List Sheet 1 of 6 Term Description AddressBook List of destinations used with the MessageBook for inbound messaging Alarm A report following an evaluation and interpretation of an event or fault that is usually routed to a system operator Automatic Attendant Group A group where the caller may choose from a list one member to receive the message Barring Message deposit is not accepted Billing Interface A system interface providing subscriber provisioning capabilities and past messaging information to an external computer Billing Management System A device that uses the Billing Interface to provision subscribers and retrieve message information Bureau Service An operator service providing message deposits information management and secretarial services for callers and subscribers Caller The individual who enters a message or service request into the gateway Canned Message A message that is predefined within the system or a communicator and is reference
112. rator Messaging Switch Software Installation Installing WMG System Software Motorola part number 5880567501 DB25 RJ45 adapter Motorola part number 5880550S01 DB9 RJ45 adapter Motorola part number 0180301F97 serial RJ45 RJ45 cable kit This connection requires a Null modem and DB25 DB9 adapter For Ultra based CPs 1 If the CP is running log on to the CP perform a CP software shutdown and turn the power off at the PDP and at the CP 2 Before applying power to the computer attach the DB25 DB9 serial maintenance cable between TTYA on the computer to the auxiliary serial port on the back of the x terminal see Figure 2 22 je o of of 1O lt Jo OOOO TTYA Serial Port z Auxillary 2 Figure 2 22 Connecting the X Terminal to the Ultra Primary or Secondary CP The following are the part numbers for the components of the serial cable Motorola part number 5880567501 DB25 RJ45 adapter Motorola part number 5880550S01 DB9 RJ45 adapter Motorola part number 0180301F97 serial RJ45 RJ45 cable kit April 1998 6880493G51 A 2 57 Installing WMG System Software WMG Administrator Messaging Switch Software Installation Setting the CP1 Open Boot Parameters 1 Turn on the NCD Window Manager Select Wind
113. rebuilds the kernel and then reboots The Dialogic patches are complete April 1998 6880493G51 A 3 37 Installing the UCC Software WMG Administrator Messaging Switch Software Installation Loading the UCC System Installation Script Perform the following steps to load the UCC system installation script 1 10 11 12 From the SCO UnixWare 2 1 1 login window press lt AIt E gt to exit At the root prompt type root lt Return gt At the password prompt type motorola lt Return gt Insert the UCC Install Script disk part number 0180302F23 in the disk drive At the prompt type tar xv lt Return gt Type cd ucc_install lt Return gt Type ucc_master_install lt Return gt At the prompt Type of board T1 or E1 E1 type the kind of NIC card the system has E1 or T1 lt Return gt If the system is using E1 boards at the prompt Install CN1 R2 Protocol type y lt Return gt At the prompt Number of boards 1 2 or 3 2 type the number of E1 or T1 boards 2 is the default value and press lt Return gt At the prompt Installing DSP board Yes or No No Type Y lt Return gt if your system has UAP boards Type N lt Return gt if your system does not have UAP boards If the system has UAP boards type the number of UAP boards in this UCC usually 4 For example type 4 lt Return gt Press lt Return gt to continue 6880493G51 A April 1998 WMG Administrator Me
114. ril 1998 d Enter the cost press lt Return gt to accept the default of 1 e Select all and press lt Return gt f Type q to return to the Select Main option ip window g Select in to enter ip interface window Type dis and press lt Return gt The system displays the defined IP parameters Verify the IP parameters for each of the subnets At the prompt Select menu option ip interface type q and press lt Return gt to return to the previous menu At the prompt Select menu option ip type rip and press lt Return gt The system displays Enter RIP mode off passive active type off and press lt Return gt At the prompt Select menu option ip type ping and press lt Return gt Enter the destination IP address to ping type 177 4 77 17 and press lt Return gt The enet responds that the address is alive At the prompt Select menu option ip type q and press lt Return gt to return to the previous level menu At the prompt Select menu option type sys and press lt Return gt to return to the previous level menu The Administrative Console top level menu appears At the prompt Select menu option system type reb and press lt Return gt Type y for yes to reboot the system and press lt Return gt Exit from the terminal session type Ctl At the telnet gt prompt type quit 6880493G51 A 2 41 Installing WMG System Software WMG Administrator Messaging Switch Software Installation
115. rn gt to configure The configuration screen appears Press lt Return gt at the OK to configure prompt Press lt Return gt to continue Type q and press lt Return gt to return to the main menu 6880493G51 A 2 55 Installing WMG System Software WMG Administrator Messaging Switch Software Installation Installing the WMG CP Operating System Loading CP1 Tape and Boot CD ROM Use this procedure to load the CP tape and boot the CD ROM For Themis based CPs 1 If the CP is running log on to the CP perform a CP software shutdown and turn the power off at the Power Distribution Panel PDP and at the CP 2 Remove the SCSI 2 terminator at the rear of the CP 1 VME chassis and attach the SCSI 2 cable for the CD ROM drive 3 Set the SCSI ID for the CD ROM drive to 6 4 Attach the connector labeled J2 on the three connector end of the serial console cable to the auxiliary DB9 serial port on the back of the x terminal and attach the single connector end of the cable to the TTYA B port on the front face of CP1 see Figure 2 21 Serial Port Auxillary jo 0O Gay 301SRH 297 Figure 2 21 Connecting the X Terminal to the Themis CP1 or CP2 TTA B Port The following are the part numbers for the components of the serial cable 2 56 6880493G51 A April 1998 WMG Administ
116. s April 1998 6880493G51 A 2 27 Installing WMG System Software WMG Administrator Messaging Switch Software Installation 2 28 24 Type the password iolan is the default password and press lt Return gt The Administration menu displays with additional fields 25 Select server Examine modify Server parameters from the Administration menu and press lt Return gt see Figure 2 12 The Server Configuration window appears see Figure 2 13 NCD User Services Terminal Emulator J File Options Fonts Cursors Keys Administrator ADMINISTRATION MENU Terminal 1 access Remote System Access PPP change Change login and or admin password gateway Examine modify gateway table host Examine modify host table kill Kill TCP connections on serial line line Terminal configuration organised by line port Terminal configuration organised by port quit Return to connections menu reboot Reboot Server PHerver Exanine modify Server parameters stats Examine Server statistics trap Examine modify SNMP Trap parameters CHASE IOLAN v3 5 02 CDi tserv1 Figure 2 12 Administration Menu 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation x Administrator Name IP address Subnet mask Ethernet address Language Identification Lock Password limit CR to initiate SNAP encoding Boot host Boot file Init file MOTD file Domain name Name server Installing WMG Syste
117. s Subscriber Inactive A subscriber profile programmed in the system but not available for use by the subscriber Subscriber Information The ability to manage the Subscriber Storybook DMS and Mailbox features Management Subscriber Profile A set of characteristics shared by subscribers April 1998 6880493G51 A A 5 Wireless Messaging System Terminology WMG Administrator Messaging Switch Software Installation Table A 1 The Wireless Messaging System Glossary List Sheet 6 of 6 Term Description Subscriber Storybook The set of parameters that define the characteristics and capabilities of the subscriber Subscriber Undefined A subscriber profile no longer programmed in the system Subscription The subscriber s definition in the gateway where features services and Message Communicator information are stored the Subscriber Storybook Subzone The subdividing of transmitters in one zone into smaller groups that cover smaller geographical areas several subzones can exist within one zone SuperUser A system operator that has overall control of the gateway and all other operators System Provider The individual or business entity that owns and operates the gateway messaging terminal the network provider sells or leases the gateway to the system operator if they are separate entities Text to Speech The conversion of numeric or alphanumeric messages into voice also used to enunciate messages
118. s AM or PM and press lt Return gt to accept At the prompt Select menu option system type nam and press lt Return gt 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 11 At the prompt Select menu option system type the system name and press lt Return gt Type enet1 for ethernet switch 1 or enet2 for ethernet switch 2 12 At the prompt Select menu option system type q and press lt Return gt to return to the previous level menu Setting the Ethernet Switch Bridge Level Parameters Use this procedure to set the ethernet switch bridge level parameters 1 At the prompt Select a menu option type bri and press lt Return gt The Bridge menu appears 2 At the prompt Select menu option bridge type stpS and press lt Return gt 3 The system prompts to enter a new value disabled or enabled type ena and press lt Return gt 4 At the prompt Select menu option bridge type stpM and press lt Return gt 5 The system prompts to enter a new value 20 type 6 and press lt Return gt 6 At the prompt Select menu option bridge type stpF and press lt Return gt 7 The system prompts to enter new value 15 type 4 and press lt Return gt April 1998 6880493G51 A 2 39 Installing WMG System Software WMG Administrator Messaging Switch Software Installation Setting IP Level Parameters 1 Type ip at the prompt Select
119. s from the disc drive The WMG MS system default IP addresses are contained in Appendix B Note This section takes approximately four hours to complete The Root Password window appears see Figure 2 10 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 11 12 13 Type motorola or a customer specified root password as the root password and press lt Return gt Record the root password for future use Repeat the password entry to confirm The installation is complete NCD User Services Terminal Emulator File Options Fonts Cursors On this screen you can create a root password A root password can contain any number of characters but only the first eight characters in the password are significant For example if you create alb2c3d4e5f 6 as your root password you can use aib2c3d4 to gain root access You will be prompted to type the root password twice for security the password will not be displayed on the screen as you type it gt If you do not want a root password press RETURN twice Root password Jj Press Return to continue Figure 2 10 Root Password Window 14 15 Log in to the OMC type root lt Return gt Type motorola or a customer specified root password and press lt Return gt After defining the system identification and configuration and running the WMG MS installation script disconne
120. ser interface windows and menus see Table 2 1 Table 2 1 Terminal Server Navigation Keys Left Arrow Moves the cursor left Right Arrow Moves the cursor right Up Arrow Moves the cursor up Down Arrow Moves the cursor down lt Tab gt Moves the cursor right Moves the cursor back one field or deletes a character depending on how lt Back Space gt the user configures this key lt Del gt Deletes a character lt Spacebar gt Toggles through the options for a particular field Selects the option the cursor is positioned on or selects the list of options lt Retum gt from the Connections Menu lt Esc gt Cancels the current command or takes the user back one menu April 1998 6880493G51 A 2 25 Installing WMG System Software WMG Administrator Messaging Switch Software Installation Terminal Server Configuration Use the following procedure to configure the terminal server Note Power to the terminal server must be shut off before starting this procedure 10 Use an RJ 45 DB9 adapter part number 58R80550S01 and a null modem to connect the serial cable from the NCD console serial port to port 1 on Terminal Server 1 11 Push the PDP switch for Terminal Server 1 to the ON position 12 Push the Terminal Server 1 power switch to on Note This is the down position 13 Verify that the Power indicator light is on green 14 From the login prompt type su lt Return gt Note Ifthe Conne
121. ss Lightning Accidental damage Negligence neglect mishandling abuse or misuse Force Majeure and Damage caused by Shipper s Return of Equipment 8 If an item of PSG infrastructure equipment malfunctions or fails in normal use within the Warranty Period a The Customer shall promptly notify the nearest Motorola Area Customer Care Center CCC of the problem and provide the serial number of the defective item Motorola shall then at its option either resolve the problem over the telephone or issue a Return Authorization Number to the Customer The Customer shall at its cost ship the item to the Motorola Area CCC location designated at the time the Return Authorization Number is issued The Return Authorization Number must be shown on the label attached to each returned item A description of the fault must accompany each returned item The returned item must be properly packed and the insurance and shipping charges prepaid Motorola shall either repair or replace the returned item The replacement item may be new or refurbished When refurbished it shall be equivalent to new in operation When a returned item is replaced by Motorola the returned item shall become the property of Motorola x Revised July 1997 d Subject to all the terms of this Warranty part availability and the clearance of Customs Motorola shall complete the repair or exchange of Motorola manufactured equipment returned under Warranty within fi
122. ssaging Switch Software Installation Installing the UCC Software 13 Remove the floppy disk and press lt Return gt to reboot the system The system displays a series of installation and configuration messages When these messages conclude installation of the clone script is complete April 1998 6880493G51 A 3 39 Installing the UCC Software WMG Administrator Messaging Switch Software Installation Configuring the UCC System Configure the UCC as follows 1 10 11 12 13 14 15 At the root prompt type root lt Return gt At the password prompt type motorola lt Return gt Set the run level to 1 type init 1 lt Return gt At the prompt UCC gt Login type root lt Return gt At the prompt UCC gt Password type motorola lt Return gt To change directories to install type ed ucc_install lt Return gt To execute the following script to configure the system type ucc_system_install lt Return gt Type the UCC ID The range is 1 64 and reflects the total number of UCCs a system can have If this is the first UCC type 1 lt Return gt Press lt Return gt to continue Type N lt Return gt at the prompt Configure TELCO boards Type Y lt Return gt at the prompt Configure UCC for redundant CPs Type N lt Return gt at the prompt Configuring UCC for SS7 Press lt Return gt to continue Press lt Space bar gt until Time Zone prompt appears At the prompt
123. t The system reboots to the SCO UnixWare 2 1 1 login window Installation of the UnixWare patch is complete April 1998 6880493G51 A 3 25 Installing the UCC Software WMG Administrator Messaging Switch Software Installation Installing UnixWare 2 1 2 OS Upgrade Follow this procedure to upgrade UnixWare 2 1 2 part number 0180302F49 1 10 Press lt Alt E gt to get to the command line At the root prompt type root lt Return gt At the password prompt type motorola lt Return gt To set the run level to 1 type init 1 lt Return gt This command changes the run level to 1 and logout At the root prompt type root lt Return gt At the password prompt type motorola lt Return gt Type usr bin installed lt Return gt The following message appears This script will install Update 2 1 1 Update 2 1 2 and the Internet components Press lt Return gt The following message appears update211 update212 pmd Installation of Unixware Update 2 1 1 in progress Please Wait Installation of UnixWare Update 2 1 2 update212 was successful At the prompt type the Serial Number and Activation Key from the SCO Unixware Internet Server Certificate of License and Authenticity The Serial Number and Activation Key are case sensitive enter the information exactly as it appears then Apply Type No to all Internet Fast Start Set packages then Apply 6880493G51 A April 1998 WMG
124. t of WMG MS terms and definitions 1 2 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Introduction Purpose This manual presents installation and configuration instructions for the WMG MS software This manual also includes software installation instructions for the UCC and peripheral equipments Audience This manual is intended for system administrators and technicians responsible for installing WMG MS software and hardware Motorola recommends users of this manual have a strong knowledge of messaging systems UNIX and telecommunications in general Motorola WMG MS training is recommended see the Service Training section in the foreword of this manual Other Publications e WMG Administrator Subscriber Database Operation number 6880492G22 e WMG Administrator UCC Port Administration number 6880492G23 e WMG Administrator System Administration number 6880492G21 e WMG Administrator Installation number 6880493G15 e WMG Administrator Hardware Installation Ultra Computer number 6880493G50 e WMG Administrator Hardware Installation Themis Computer number 6880493G52 Note You should also have the appropriate test equipment instruction manuals available April 1998 6880493G51 A 1 3 Introduction WMG Administrator Messaging Switch Software Installation Conventions Used in this Manual Table 1 1 defines the notational conventions used in this manual
125. te The front panel menu does not respond unless the printer has paper in the paper tray 2 Turn the printer power distribution switch ON 3 Turn the printer ON 4 Press lt On Line gt on the front control panel of the printer to set the printer to off line 5 Press lt Menu gt until HP MIO MENU appears on the printer display 6 Press lt Item gt until CFG NETWORK NO appears on the printer display 7 Press lt Value gt until CFG NETWORK YES appears on the printer display 8 Press lt Select gt until CFG NETWORK YES appears on the printer display 9 Press lt Item gt until NOVELL appears on the printer display 10 Press lt Item gt then lt gt until NOVELL ON appears on the printer display 11 Press lt Value gt then lt gt until NOVELL OFF appears on the printer display 12 Press lt Select gt 13 Press lt Item gt then lt gt until DLC LLL appears on the printer display 14 Press lt Value gt then lt gt until OFF appears on the printer display 15 Press lt Select gt 16 Press lt Item gt until TCP IP appears on the printer display 2 50 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software 17 18 19 20 21 22 23 24 25 26 27 28 29 Press lt Value gt then lt gt until ON appears on the printer display Press lt Select gt Press lt
126. tem 2 56 Loading WMG Applications 2 69 Installing the UCC Software 3 1 UCC Software Installation Overview 3 2 Required Tools and Equipment 3 3 Running the WinBIOS Setup 3 5 Configuring the Ethernet Boards 3 11 Installing UnixWare 2 1 or 2 1 2 3 15 Installing UnixWare 2 1 1 OS Upgrade 3 23 Installing UnixWare 2 1 2 OS Upgrade 3 26 Installing E1 or T1 Dialogic Software 3 29 Installing the Global Call Development Package 3 34 Installing the R2 Protocol Disk E1 Option Only 3 36 April 1998 6880493G51 A xiii Contents WMG Administrator Messaging Switch Software Installation Loading Dialogic Patches 3 37 Loading the UCC System Installation Script 3 38 Configuring the UCC System 3 40 Generating the Clone Tape 3 42 Restoring the UCC System Cloning Tape 3 45 Wireless Messaging System Terminology A 1 IP Addresses and Network Diagram B 1 xiv 6880493G51 A April 1998 Figures Figure 1 1 Figure 1 2 Figure 1 3 Figure 2 1 Figure 2 2 Figure 2 3 Figure 2 4 Figure 2 5 Figure 2 6 Figure 2 7 Figure 2 8 Figure 2 9 Figure 2 10 Figure 2 11 Figure 2 12 Figure 2 13 Figure 2 14 Figure 2 15 Figure 2 16 Figure 2 17 Figure 2 18 Figure 2 19 Figure 2 20 Figure 2 21 Figure 2 22 Figure 2 23 Figure 2 24 Figure 2 25 April 1998 WMG Administrator Messaging Switch Software Installation The WMG Administrator MS and the Wireless Messaging System 1 6 WMG MS Typical Red
127. the CPs the OMC the FS terminal server s and ethernet switches Each cabinet of the WMG MS contains a power distribution panel PDP and if the site power is 48Vdc each cabinet contains a power inverter The first cabinet houses the CP OMC and the FS The second cabinet houses up to six DC configuration or seven UCCs 110 or 220 Vac configuration and ethernet switches The third through eleventh cabinets contain only UCCs seven in the DC configuration eight in the AC configuration If the system comes with the full redundant option it contains two of the following subsystems e CP e Media converter e Ethernet switch WMG MS also includes the following peripheral devices e Terminal servers e Alarm notification device e Printers optional e Power inverter optional April 1998 6880493G51 A 1 7 Introduction WMG Administrator Messaging Switch Software Installation O POWER DISTRIBUTION PANEL OJ O POWER DISTRIBUTION PANEL OJ lo 1239 45 67 swn o lo 123 4 5 6 7 8 8 oH B Q op Tro z el lo AND 1 d lo Ol O g H b
128. the CD ROM drive from Themis based CPs after completing the previous procedure 3 Type sync lt Return gt 4 Type halt lt Return gt This shuts down the Solaris operating system 5 Wait for the OpenBoot ok prompt 6 Turn off the power to the CD ROM and the CP 7 Disconnect the SCSI cable between the CD ROM drive and the CP SCSI port on the back of the CP chassis 8 Plug the SCSI 2 terminator into the SCSI port on the back of the CP1 9 Remove the console cable connected to the serial port of the x terminal 10 Turn the power on to CP1 The system reboots Repeat this procedure starting from the paragraph Loading CP1 Tape and Boot CD ROM for CP2 if equipped 2 68 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software Loading WMG Applications This section describes the procedure for installing and configuring the WMG MS application software Overview WMG MS applications install after the WMG MS system software and the UCC software The following shows the WMG MS applications installation process e FS config configfs factory e OMC install install factory e Create OMC database install_after_reboot e CP1 and CP2 install install factory e UCC install ucc_app_install e License Report Writer setiqlic File Server Configuration 1 At the omc prompt run the file server install script by typing cd usr local wmg config lt
129. the CP VME chassis SCSI termination appropriate for the CD ROM drive e Software Media Solaris CD ROM version 2 5 1 Hardware 8280520F33 SunSoft label information May 1996 Part 704 5235 10 Revision A WMG installation tape Package Load DAT Tape 0180302F82 2 4 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing WMG System Software e X terminal supplied with the system e Serial cable made of the following three parts Motorola Part 5880567S01 DB25 RJ45 adapter Motorola Part 5880550S01 DB9 RJ45 adapter Motorola Part 0180301F97 serial RJ45 RJ45 cable kit e Software license information for the following Solaris ID and system environment ID Informix keycards Report Writer WMG Application licenses Required Equipment for Sun Ultra based systems Assemble the following items to perform the software installation procedures for Ultra based systems e Software Media Solaris CD ROM version 2 5 1 Hardware 8280520F33 SunSoft label information May 1996 Part 704 5235 10 Revision A The WMG installation tape Package Load DAT Tape 0180302F82 e X terminal supplied with the system e Serial cable made of the following three parts Motorola Part 5880567S01 DB25 RJ45 adapter Motorola Part 5880550S01 DB9 RJ45 adapter Motorola Part 0180301F97 serial RJ45 RJ45 cable kit e Software license information for the following
130. tion Installing the Global Call Development Package Use this procedure to install the Global Call Development Package 1 10 11 12 13 14 15 From the SCO UnixWare window type lt Alt E gt to exit At the root prompt type root lt Return gt At the password prompt type motorola lt Return gt Insert the Dialogic Global Call disk part number 8280520F44 1 of 2 in the UCC disk drive At the prompt type installpkg lt Return gt Type F to install from the floppy disk Press lt Return gt to continue The system displays the message Installation in progress At the prompt eject the Dialogic Global Call disk 1 of 2 and insert the Dialogic Global Call disk part number 8280520F44 2 of 2 Press lt Return gt to continue At the prompt Do you wish to install the library type y lt Return gt At the prompt Do you wish to install the demos type y lt Return gt At the prompt Do you wish to change the default destination type n lt Return gt At the prompt Would you like to view the release notes type the appropriate response and press lt Return gt At the prompt eject the Global Call disk 2 of 2 Insert the Dialogic ICAPI Call Control Library disk part number 8280520F44 1 of 2 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software 16 17 18 19 20 21 22 23 24 Type i
131. to reboot Installation of the UnixWare upgrade is complete Installing UnixWare 2 1 1 OS Patches 3 24 Follow these steps to upgrade the UnixWare 2 1 1 OS 1 At the SCO UnixWare 2 1 1 window press lt AIt E gt to exit 2 At the root prompt type root lt Return gt 3 At the password prompt type motorola lt Return gt 4 Type cd ux2 1 1 lt Return gt 5 Type addpatch01 lt Return gt 6 Press lt Return gt at each prompt to accept all defaults 7 Press lt Return gt to continue with installation 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software 8 Type the following to add the remaining patches addpatchxx lt Return gt Where xx is 02 03 04 06 05 07 The Network Interface Card Support utility executes while installing patch 03 Note Add patches in this order 02 03 04 06 05 07 Patch 06 must be installed before patch 05 The command Addpatch07 displays the error message driver does not exist Disregard this message 9 For each patch press lt Return gt to select all defaults 10 Install patch 04 after the following prompt Release Notes IMPORTANT NOTICE Package ptf3123 locks down ptf 3107 Package pft3107 cannot be removed 11 Press lt Return gt at the Network Interface Card Support Utility window 12 When all patches are installed type cd lt Return gt 13 Type shutdown y g0 i6 lt Return g
132. tomer a Assigns or transfers the Customer s rights or obligations under this Warranty without the prior written consent of Motorola or b Within thirty 30 days of written demand by Motorola fails to pay 1 any charge for Advance Replacement Parts supplied under this Warranty if the Customer has not timely returned the defective items or 2 any other amount that may be due Notwithstanding any such termination of the Warranty to the Customer the Customer shall remain responsible for all amounts then due Limitation of Liability 15 IN NO EVENT SHALL MOTOROLA BE LIABLE FOR ANY INDIRECT INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THIS WARRANTY EVEN IF MOTOROLA HAS BEEN ADVISED OF THE POSSIBILITY THEREOF INCLUDING WITHOUT LIMITATION LOST PROFITS AND REVENUES FAILURE TO REALIZE EXPECTED SAVINGS LOST DATA OR ANY CLAIMS AGAINST THE CUSTOMER BY A THIRD PARTY Revised July 1997 WMG Administrator Messaging Switch Software Installation Contents Introduction 1 1 About This Manual 1 2 WMG MS Overview 1 5 Installing WMG System Software 2 1 WMG MS Software Installation Overview 2 3 System Software Installation Required Materials 2 4 Configuring the X Terminal 2 6 Installing the OMC Operating System and Database 2 12 Configuring the Terminal Server 2 25 Configuring the Ethernet Switch 2 37 Configuring File Server Software 2 43 Local Printer Setup 2 48 Installing the WMG CP Operating Sys
133. tor Messaging Switch Software Installation Installing the UCC Software 10 Insert the UnixWare Host Bus Adapter Drivers Patches Release 2 1 disk 0180302F54 11 From the Choices pop up menu select Install Host Bus Adapter Driver HBA lt Return gt The system displays Please wait loading HBA hardware driver 12 From the Choices pop up menu select Install Another HBA Diskette lt Return gt 13 Insert the UnixWare Host Bus Adapter Drivers Release disk part number 0180302F36 or 0180302F49 The system displays please wait loading HBA hardware driver 14 From the Choices pop up menu select Continue Installation lt Return gt 15 Again from the Choices pop up menu select Continue Installation lt Return gt The system displays Please wait while the system hardware drivers are loaded 16 From the Select Installation Method window select Install From CD ROM lt Return gt Note Ifthe CD ROM option does not appear check the CD ROM cable power or for an incorrect software driver 17 From the Choices pop up menu select Yes continue the installation and press lt Return gt 18 If you have previously installed UnixWare 2 1 select Perform Destructive Installation and press lt Return gt The Destructive Installation pop up menu appears 19 From the Destructive Installation pop up menu select Use the Entire Disk for UnixWare 2 1 Erase All Partitions lt Return gt 20 For the System
134. tware Installation Installing the UCC Software 13 Press lt F2 gt to display Choices for the Format Removable Media pop up window 14 Press lt F3 gt to select diskette1 from the Device Drive Choices pop up window 15 Press lt F3 gt to continue from the Format Removable Media pop up menu 16 To save select 3 5 1 44 lt F3 gt 17 From the Format Removable Media pop up window press lt F3 gt to continue The message Formatting in Progress appears 18 Eject disk 1 insert disk 2 and press lt F3 gt to continue 19 Press lt F3 gt to continue with formatting of the second disk 20 When the message Format of Volume Complete appears remove the second disk 21 Press lt F6 gt for cancel to back out of this menu 22 Press lt F7 gt for the Command menu Use the down arrow to scroll and select Exit 23 From the prompt type emergency_disk diskette1 lt Return gt 24 Insert Clone disk 1 and press lt Return gt 25 When the prompt appears eject Clone disk 1 insert Clone disk 2 and press lt Return gt 26 Insert the blank 4 mm DAT tape in the tape drive 27 Type emergency_rec ctape1 lt Returm gt 28 Press lt Return gt to continue The process takes approximately 30 minutes When complete the message Creation of Emergency Recovery Tape was successful appears 29 Eject the floppy disk 30 Eject the 4 mm DAT tape April 1998 6880493G51 A 3 43 Installing the UCC Software WMG Administrator
135. ue the installation At the prompt Do you wish to continue installing DTI drivers yn type N lt Return gt At the prompt Do you wish to continue with installation yn type Y lt Return gt At the prompt Would you like to view the release notes yn type the appropriate response and press lt Return gt The system displays the message The installation of the Dialogic DTI UNIX Development Package Version 4 2 is now complete Press lt Return gt to continue the installation The system displays the messages The following package installations now require a UNIX system kernel rebuild Dialogic Generic Voice Development Platform Version 4 2 At the prompt Do you wish to build a kernel now yn type Y lt Return gt The system displays The unix kernel will be rebuilt to include your configuration changes during the next system reboot Installation complete Unix kernel rebuilt successfully Reboot the system before starting the Dialogic Packages 6880493G51 A April 1998 WMG Administrator Messaging Switch Software Installation Installing the UCC Software 39 Remove the disk from the disk drive 40 Type shutdown y g0 i6 lt Return gt After rebooting the SCO UnixWare 2 1 1 Welcome window appears The installation of the System Release for Dialogic Version 4 2 is now complete April 1998 6880493G51 A 3 33 Installing the UCC Software WMG Administrator Messaging Switch Software Installa
136. ug 26 18 18 33 PDT 1996 Copyright c 1992 1996 Network Appliance Inc Scanning for disk drives Configuring disk drives 0 0 0 1 0 2 Loading file system ifconfig ioctl SIOCAIFADDR File exists NFS server is running Tue Apr 22 07 37 45 CDT rc NetApp Release 3 1 4d boot complete Password Tue Apr 22 07 37 49 CDT asup_main System Notification mail sent Password Tue Apr 22 07 37 49 CDT asup_main System Notification mail sent Tue Apr 22 07 38 27 CDT tty_login_mgr Login from console fsv gt maxfiles 1935629 The new maximum number of files specified is more than twice as big as it needs to be based on current usage patterns Increasing the maximum number of files consumes disk space and the number can never be decreased Are you sure you want to increase the maximum number of files yes fsv gt maxfiles Maximum number of files is currently 1935629 9300 used Figure 2 20 File Server Configuration April 1998 6880493G51 A 2 47 Installing WMG System Software WMG Administrator Messaging Switch Software Installation Local Printer Setup The HP 4MP and HP 5M printers are supported for use with the WMG MS This section contains a separate configuration procedure for each printer Setting up the HP 4MP Use the printer control panel to perform the following configuration procedure for the HP 4M printer 1 Verify that that the printer has paper Note The front panel menu does not respond un
137. undant DC Powered Two Cabinet Configuration Without SS7 1 8 WMG MS Typical DC Powered Third Cabinet Configuration with Four UCCs 1 9 Boot Monitor Main Menu 2 7 Connecting the NCD X Terminal to the OMC TTYA B Port Themis Systems 2 9 Connecting the NCD X terminal to the OMC console Port Ultra Based Systems 2 10 NCD User Services Console Window 2 11 Openboot Parameters for OMC 2 14 Terminal Selection 2 16 Install Solaris Software Initial 2 19 Exit Solaris Installation Window 2 20 Information Installation Script Menu 2 22 Root Password Window 2 23 Terminal Server Connections 2 27 Administration Menu 2 28 Server Configuration Window for Version 3 5 02 2 29 Server Configuration Window for Version 4 00 19 2 30 Administration Menu 2 32 Administration Menu 2 34 Server Configuration window 2 35 IP Level Parameters 2 40 File Server Setup Menu 2 44 File Server Configuration 2 47 Connecting the X Terminal to the Themis CP1 or CP2 TTA B Port 2 56 Connecting the X Terminal to the Ultra Primary or Secondary CP 2 57 NCD User Services Console Window 2 58 Select Type of Terminal 2 61 Solaris Installation Program Window 2 62 6880493G51 A xv Figures WMG Administrator Messaging Switch Software Installation Figure 2 26 Install Solaris Software 2 64 Figure 2 27 Exit Solaris Installation Window 2 65 Figure 2 28 Root Password Window 2 67 Figure 2 29 UCC Application Installation Window
138. word WMG Administrator Messaging Switch Software Installation Heed Admonitions Adhere to all warnings on the equipment and in the operating instructions Follow all operating and use instructions Two safety admonitions are used in this instruction manual to indicate e Equipment damage This safety admonition applies to an operating or maintenance procedure practice or condition which if not strictly observed could result in damage to the equipment or database e Personal injury or injury that may result in death This safety admonition applies to an operating or maintenance procedure practice or condition which if not strictly observed could result in serious personal injury or death Mounting Mount the equipment only as recommended by the manufacturer Situate the equipment away from heat sources such as radiators heat registers stoves or other equipment including amplifiers that produces heat Power Sources and Grounding Connect the equipment to the type of power source described in the installation instructions or as marked on the equipment Take precautions to avoid defeating the grounding or polarization provisions of the equipment Disconnect the power to the equipment by a circuit breaker when left unused for long periods of time Cleaning Clean the outside of the equipment by using only a damp cloth Do not immerse the equipment in any type of liquid including water Do not use liquid cleaners or aerosol clean
139. y This Warranty shall commence 30 days after the date of shipment of the PSG infrastructure equipment The term of Warranty for all PSG infrastructure equipment is one 1 year parts and labor Limitations And Qualifications of Warranty 6 Revised July 1997 ix VOU I F LIMITATION THE REMEDY UNDER THIS WARRANTY IS LIMITED TO MOTOROLA S REPAIR OR REPLACEMENT OF DEFECTIVE EQUIPMENT THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE This Warranty does not cover nor include a remedy for damages defects or failure caused by a The equipment or any part of it NOT having been installed modified adapted repaired maintained transported or relocated in accordance with Motorola technical specifications and instructions b ph mB ag Storage not conforming to the Shipping Receiving and Installation section of the applicable Motorola Equipment Manual Environmental characteristics not conforming to the applicable Motorola Equipment Manual Nonconformance with the Equipment Operating Instructions in the applicable Motorola Equipment Manual External causes including without limitation use in conjunction with incompatible equipment unless such use was with or under Motorola s prior written consent Cosmetic damages Damages caused by external electrical stre
140. ystem responds installing drivers From the Multiple Card Init Setup Values window select the first card on the list and enter the following information a Configure as gateway no b Device handle SMC8K_0 c Node Name uce1v ucc2v ucc3v and so on for additional UCCs d Network Frame Type leave blank Press lt F10 gt to apply 6880493G51 A 3 19 Installing the UCC Software WMG Administrator Messaging Switch Software Installation 42 From the System Values window enter the following information a System IP address for ucclv 177 4 78 101 See Appendix B for additional UCC IP addresses b System Netmask Oxffffff00 Note Disregard the remaining entry fields 43 44 45 46 Press lt F10 gt to apply Select the second card from the Multiple Card Init Setup Values pop up window and enter the following information a Configure as gateway no b Device handle SMC8K_1 c Node Name ucc1c ucc2v ucc3v and so on for additional UCCs d Network Frame Type leave blank Press lt F10 gt to apply From the Inet Setup Values From System Values window enter the following information a System IP address 177 4 77 101 See Appendix B for additional UCC IP addresses b System Netmask Oxffffff00 Note Disregard the remaining entries 47 48 49 50 51 Press lt F10 gt to apply Select Exit from Init Setup lt Return gt From the Network Information Service