Home

MCP-310-49002-0N

image

Contents

1. Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands 31 0 73 6400390 31 0 73 6416525 sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Super Micro Computer Inc 4F No 232 1 Liancheng Rd Chung Ho 235 Taipei County Taiwan R O C 886 2 8226 3990 886 2 8226 3991 www supermicro com tw support supermicro com tw 886 2 8226 5990 SC743 X9 Universal Air Shroud User s Guide Notes Chapter 2 System Safety Please read and follow all safety precautions below before using your Supermicro product 2 1 Electrical Safety Precautions Basic electrical safety precautions should be followed to protect yourself from harm and the server from damage Be aware of how to power on off the enclosure power supplies and the individual blades as well as the room s emergency power off switch disconnection switch or electrical outlet If an electrical accident occurs you can then quickly remove power from the system Do not work alone when working with high voltage components Power should always be disconnected from the blade module when removing or installing such system components as the mainboard memory modules and processors When working around exposed electrical circuits another person who is familiar with the power off controls should be nearby to switch off the power if necessary Use only one hand when workin
2. e Place the blade module cover and any system components that have been removed away from the system or on a table so that they won t accidentally be stepped on e While working on the system do not wear loose clothing such as neckties and unbuttoned shirt sleeves which can come into contact with electrical circuits or be pulled into a cooling fan Remove any jewelry or metal objects from your body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present After accessing the inside of the system replace the blade module s cover before installing it back into the blade enclosure 2 3 Electrostatic Discharge Precautions Electrostatic discharge ESD is generated by two objects with different electrical charges coming into contact with each other An electrical discharge is created to neutralize this difference which can damage electronic components and printed circuit boards The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD Use a grounded wrist strap designed to prevent static discharge Keep all components and printed circuit boards PCBs in their antistatic bags until ready for use e Touch a grounded metal object before removing the board from the antistatic bag Do not let components or PCBs come into contact with your clot
3. 3 4 for details on configuring the air shroud 2 Secure the rear edge of the SC743 air shroud Component Part A to the top rear part of the chassis interior so that the SC743 air shroud mounting screw holes are aligned in with the mounting screw holes of the chassis Align it so that the slot of the air shroud s front mounts with the mounting tab at the top front part of the chassis interior see Figure 3 7 Figure 3 7 Inserting Air Shroud onto a System Mainboard Mounting Holes in Rear of Component A Mounting Slot on Air Mounting Holes in Top Rear Edge Mounting Tab of Chassis Interior De on Chassis li 3 Make sure the SC743 X9 universal air shroud is mounted directly on the mainboard of its system so that the air shroud covers the system mainboard over the CPU s and memory slots 3 7 SC743 X9 Universal Air Shroud User s Guide NOTE The air shroud should be mounted flush with the power supply housing if installing properly Some cables are supposed to go under the air shroud Detach breakaway tabs if required for cable access 4 Secure the top cover back on your system 3 8 Disclaimer The products sold by Supermicro are not intended for and will not be used in life support systems medical equipment nuclear facilities or systems aircraft ai
4. Ge GR Re 2 1 2 2 General Safety Precautions 2 2 2 3 Electrostatic Discharge Precautions U 2 2 2 4 Operating Precautions 2 2 Chapter 3 Configuration and Installation 3 1 Ke RE EE EE ee N 3 1 3 2 SC743 X9 Universal Air Shroud Componen e 3 1 Component PartB i e Ee LEKE eg ika a Aina ee EER ES eg ee Ee 3 2 Component Pat Dui EE ER genie intimes 3 3 Component Part E sis esse ees ne dike dek ige ee er ad sewaba nek yada ken 3 4 3 3 Removing Breakable Tabs for Cabling 3 5 3 4 Configuring the SC743 X9 Universal Air Shroud 3 6 3 5 Installing the SC743 X9 Universal Air Shroud 3 7 SC743 X9 Universal Air Shroud User s Guide Notes Vi Chapter 1 Introduction 1 1 Overview The SC743 X9 universal air shroud is a configurable air shroud for system mainboards to enable maximum efficient air flow through the system It can be configured to fit 12 X13 MB Extended ATX sized system mainboards The SC743 X9 universal air shroud is optimized for use with Supermicro SC743 series chassis designs and for Supermicro X9DRx X8DTx and H8DGx series mainboards See Chapter 3 for configuration details 1 2 Product Checklist of Typical Components
5. arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California USA The State of California County of Santa Clara shall be the exclusive venue for the resolution of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful interference with radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be required to correct the interference at your own expense Manual Revison 1 0 Release Date September 22 2011 Unless you request and receive written permission from Super Micro Computer Inc you may not copy any part of this document Information in this document is subject to change without notice Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders Copyright 2011 by Super Micro Computer Inc All r
6. Components Item Description M OW SC743 X9 universal air shroud component main body Part A SC743 X9 universal air shroud component moving part Part B SC825 826 216 213 X9 universal air shroud component tear drop 33mm Part D SC743 X9 universal air shroud component moving part Part E The SC743 X9 universal air shroud comes with the main body and three detachable component parts Figure 3 1 and Table 3 1 See below for details on these various component parts These component parts can be used to create multiple different configurations for use in sytems The SC743 X9 universal air shroud is optimized for use with Supermicro X9DRx X8DTx and H8DGx series mainboards See Section 3 4 for further details on configurations 3 1 SC743 X9 Universal Air Shroud User s Guide Component Part B Figure 3 2 Moving Component Part B The SC743 X9 universal air shroud s Component Part B Figure 3 2 can be moved in and out to resize the X9 universal air shroud s size to fit the mainboard using three sliding positions A B and C The bottom of Component Part B can be detached to allow for cable access under the air shroud Chapter 3 Configuration and Installation Component Part D Figure 3 3 Component Part D Component Part D Locking Tabs The SC743 X9 universal air shroud s Component Part D Figure 3 3 33mm wide tear drop module can be mounted on the undersi
7. SUPERMICR SC743 X9 Universal Air Shroud User s Guide Revison 1 0 SC743 X9 Universal Air Shroud User s Guide The information in this User s Guide has been carefully reviewed and is believed to be accurate The vendor assumes no responsibility for any inaccuracies that may be contained in this document makes no commitment to update or to keep current the information in this manual or to notify any person or organization of the updates Please Note For the most up to date version of this manual please see our web site at www supermicro com Super Micro Computer Inc Supermicro reserves the right to make changes to the product described in this manual at any time and without notice This product including software and documentation is the property of Supermicro and or its licensors and is supplied only under a license Any use or reproduction of this product is not allowed except as expressly permitted by the terms of said license IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA Any disputes
8. The SC743 X9 universal air shroud comes packaged with components parts as shown in Table 1 1 Table 1 1 SC743 X9 Universal Air Shroud Parts and Components Part Number MCP 310 49002 0N MCP 310 49009 1N MCP 310 49010 1N MCP 310 29005 1N MCP 310 49011 1N Description SC743 Intel DP X9 universal PC air shroud 12 x13 MB SC743 X9 universal air shroud component main body Part A SC743 X9 universal air shroud component moving part Part B SC825 826 216 213 X9 universal air shroud component tear drop 33mm part D SC743 X9 universal air shroud component moving part Part E Quantity connected f NOTE The default configuration is for Component Parts A B D and E with its component part letter for easy identification f NOTE Each individual part for the SC743 X9 universal air shroud is labeled 1 1 SC743 X9 Universal Air Shroud User s Guide 1 3 Features The SC743 X9 universal air shroud includes the following features e Main air shroud component Three detachable components for creating multiple configurations e Breakable sections for power cable management e Clear plastic material construction for ease of viewing 1 4 Returning Merchandise for Service A receipt or copy of your invoice marked with the date of purchase is required before any warranty service will be rendered You can obtain service by calling your vendor for a Returned Merchandise Authorization RMA number W
9. ached with three positions each for Component Parts B and E and three possible locking positions for Part D many possible combinations can be configured for the SC743 X9 universal air shroud With parts detached more configurations are possible Some recommended example configurations for specific Supermicro motherboards are shown below in Table 3 2 All are 12 x 13 E ATX Intel Xeon or AMD Opteron motherboards Table 3 2 Examples of SC743 X9 Universal Air Shroud Configurations BE a Slot and Tab Positions X9DA6 Tab Position C Part B Tab Position 2 Part E and Slot Positon b Part D X9DR6 F Tab Position B Part B Tab Position 2 Part E and Slot Positon c Part D X8DT6 F Tab Position A Part B Tab Position 0 Part E and Slot Positon b Part D H8DG6 Tab Position B Part B Tab Position 1 Part E and Slot Positon b Part D NOTE The default configuration is with Component Parts A B D and E already connected Figure 3 6 Figure 3 6 Default Configuration 3 6 Chapter 3 Configuration and Installation 3 5 Installing the SC743 X9 Universal Air Shroud To install the SC743 X9 universal air shroud follow the procedure below This procedure is the same for all configurations of the SC743 X9 universal air shroud in Supermicro systems Installing the SC743 X9 Universal Air Shroud in SC743 Chassis Systems 1 Configure the air shroud to fit in your system See Section
10. de of Component Part A by inserting its locking tabs into the alignment slots provided on Component Part A Three positions are indicated for attaching the first tab of Component Part D into the locking tab slots on Component Part A labeled a o and c Component Part D may also be removed out if it is not required 3 3 SC743 X9 Universal Air Shroud User s Guide Component Part E Figure 3 4 Moving Component Part E The SC743 X9 universal air shroud s Component Part E Figure 3 4 can be moved in and out to resize the X9 universal air shroud s size to fit the mainboard using three sliding positions 0 1 and 2 The bottom of Component Part E can also be detached to allow for cable access under the air shroud Chapter 3 Configuration and Installation 3 3 Removing Breakable Tabs for Cabling Figure 3 5 Removing the Breakable Tabs Breakable Tabs Component Parts B and E for the SC743 X9 universal air shroud have breakable tabs that can be permanently removed to allow cabling access if reguired for your system see Figure 3 5 for details To remove simply cut or break the tabs off from their attachments with a pair of scissors and discard them 3 5 SC743 X9 Universal Air Shroud User s Guide 3 4 Configuring the SC743 X9 Universal Air Shroud The SC743 X9 universal air shroud can be customized into multiple configurations for Supermicro systems With all parts att
11. g with powered on electrical equipment This is to avoid making a complete circuit which will cause electrical shock Use extreme caution when using metal tools which can easily damage any electrical components or circuit boards they come into contact with Do not use mats designed to decrease electrostatic discharge as protection from electrical shock Instead use rubber mats that have been specifically designed as electrical insulators The power supply power cords must include a grounding plug and must be plugged into grounded electrical outlets Power input requires 110 240 VAC depending upon your power supply module Mainboard Battery This battery must be replaced only with the same or an equivalent type recommended by the manufacturer CR2032 Lithium 3V battery Dispose of used batteries according to the manufacturer s instructions WARNING There is a danger of explosion if the onboard battery is installed A upside down which will reverse its polarities Mainboard replaceable soldered in fuses Self resetting PTC Positive Temperature Coefficient fuses on the mainboard must be replaced by trained service technicians only The new fuse must be the same or equivalent as the one replaced Contact technical support for details and support 2 1 SC743 X9 Universal Air Shroud User s Guide 2 2 General Safety Precautions Follow these rules to ensure general safety e Keep the area around the server clean and free of clutter
12. hen returning to the manufacturer the RMA number should be prominently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is complete For faster service RMA authorizations may be requested online at http www supermicro com support rma Whenever possible repack the chassis in the original Supermicro carton using the original packaging material If these are no longer available be sure to pack the chassis securely using packaging material to surround the chassis so that it does not shift within the carton and become damaged during shipping This warranty only covers normal consumer use and does not cover damages incurred in shipping or from failure due to the alteration misuse abuse or improper maintenance of products During the warranty period contact your distributor first for any product problems 1 2 Chapter 1 Introduction 1 5 Contacting Supermicro Headquarters Address Tel Fax Email Web Site Europe Address Tel Fax Email Asia Pacific Address Tel Fax Web Site Technical Support Email Tel Super Micro Computer Inc 980 Rock Ave San Jose CA 95131 U S A 1 408 503 8000 1 408 503 8008 marketing supermicro com General Information support supermicro com Technical Support www supermicro com Super Micro Computer B V
13. hing which may retain a charge even if you are wearing a wrist strap Handle a board by its edges only do not touch its components peripheral chips memory modules or contacts When handling chips or modules avoid touching their pins Put the mainboard and peripherals back into their antistatic bags when not in use For grounding purposes make sure the blade enclosure provides excellent conductivity between the power supplies the blade modules and the mainboard 2 4 Operating Precautions Care must be taken to assure that the cover of the blade unit is in place when the blade is operating to assure proper cooling Out of warranty damage to the blade can occur if this practice is not strictly followed Any drive carrier without a hard drive installed must remain fully installed in the drive bay when the blade module is operating to ensure proper airflow 2 2 Chapter 3 Configuration and Installation 3 1 Overview This chapter covers the configuration and installation of the SC743 X9 universal air shroud into a server or into a chassis The main section Component Part A is connected to other sections Component Parts B D and E to make up many possible configurations based upon the sliding positions of the components and locking tabs even more if parts are detached 3 2 SC743 X9 Universal Air Shroud Components Figure 3 1 SC743 X9 Universal Air Shroud Components Table 3 1 SC743 X9 Universal Air Shroud
14. ights reserved Printed in the United States of America Preface About this Manual This manual is written for professional system integrators Information Technology professionals service personnel and technicians It provides information for the installation and use of Supermicro s SC743 X9 universal air shroud Installation and maintenance should be performed by experienced professionals only Manual Organization Chapter 1 Introduction The first chapter provides a checklist of the main components included with the SC743 X9 universal air shroud and describes its main features Chapter 2 System Safety You should familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SC743 X9 universal air shroud Chapter 3 Configuration and Installation Refer here for details on installing the SC743 X9 universal air shroud on a computer system mainboard SC743 X9 Universal Air Shroud User s Guide Notes Table of Contents Chapter 1 Introduction 1 1 1 1 Overview sise 1 1 1 2 Product Checklist of Typical Componen e 1 1 1 S Eeature8 n hin alain anti Ge EG Deed 1 2 1 4 Returning Merchandise for Service 1 2 1 5 Contacting Supermicro ee ee se ek ee Ge GR Re Ge GR RR Ge Ge RR Ge Re 1 3 Chapter 2 System Safety 2 1 2 1 Electrical Safety Precauti0nS ese see ee ee ee RR Re ee GR GR ER ee
15. rcraft devices aircraft emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions litigation and proceedings of any kind arising out of or related to such ultra hazardous use or sale 1 1 SC743 X9 Universal Air Shroud User s Guide Notes

Download Pdf Manuals