Sun StorEdge network FC switch-8 and switch
Contents
1. AAVA FIGURE 3 6 Installing the Vent Panel The 8 port Four Switch Configuration v To Install the Vent Panels on a Four Switch Configuration 1 Mount each of the two vent panels over the front of a set of two switches 2 Tighten the captive screws Chapter 3 Hardware Installation 25 Sun StorEdge network FC switch 16 Switch Each of the 16 port switches comes with its own vent panel Follow the instructions for the 8 port switch Sun StorEdge network FC switch 8 switch See Sun StorEdge network FC switch 8 Switch on page 24 See FIGURE 3 7 Note The 16 port switches do not require filler panels FIGURE 3 7 Installing the Vent Panel for a 16 port Switch Installing Connecting and Routing the Cables Some storage cabinets may have shorter and fewer power cords In these cases the Y cable is provided to increase the number of power connections and provide adequate power cord length Install the Y cables only in the J8 or J12 connections of the power sequencer 26 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 Installing the Y cables in a Resident Cabinet The procedure for replacing the existing cables with the new Y cables is different for the Sun StorEdge A5200 Array and the Sun StorEdge T3 Disk Tray Sun StorEdge T3 Disk Tray Replacing the Power Cable with the Y cable Power off the syste
2. NI ss E Kr AAA gt 11 A a ZA N x Stopper screws REC CEE y FIGURE 3 2 Installing Mounting Rails Four Switch Configuration Installing the Mounting Rails for 16 Port Switches The procedure for installing the mounting rails in an expansion cabinet for a Sun StorEdge network FC switch 16 switch is different from that of the 8 port switch See FIGURE 3 3 V To Install the Rails for Two 16 Port Switches Each switch comes with two mounting rails The rails are identical to each other There is no left right difference 20 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 Preinstalling the Screws Loosely start two stopper screws into each rail before you install the rails into the cabinet see FIGURE 3 3 Working from the rear of the cabinet loosely start two screws into the cabinet for each mounting rail one at each end see FIGURE 3 3 Refer to the online Rackmount Placement Matrix for the correct hole positions for your configuration Note Install the screws into the cabinet holes before you place the rails Preinstalled screws IN NS RES I i NT Kl 71 es s ES L p 2 4 NG p Aa pe PN Te al ay o o g D Briley
3. Controller B FC AL port SCSI x 5 Fibre optic cables Drive tray x 5 FIGURE 2 1 Example Single Host Connected to One Sun StorEdge A3500FC Controller Module Using Switches Sun StorEdge A5200 controller module Host Switches Host adapter Host adapter Fiber optic cables FIGURE 2 2 Example Single Host Connected to One Sun StorEdge A5200 Controller Module Using Switches Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide April 2001 Sun StorEdge T3 Partner Pair Host Switches Host adapter Host adapter Fiber optic cables FIGURE 2 3 Example Single Host Connected to One Sun StorEdge T3 Partner Pair Using Switches Single Host Connected to Multiple Controller Modules Using Switches FIGURE 2 4 shows one host connected through fiber optic cables to as many as four StorEdge A3500FC controller modules using switches You can connect controller modules in the same or separate cabinets Note Different storage types can be attached on one switch as long as they are on different zones Each controller that is connected to a switch must have a unique loop ID Whenever you add a second controller to a switch make sure that the loop ID of the controller being connected is different from the loop ID of any other controller currently connected to the same switch See Setting the Loop ID on page 15 for instruction
4. Part Number Description 540 4026 A3500FC FC AL controller for A3500 array with D1000 tray 540 4027 A3500FC FC AL controller for A3000 array with RSM tray A5200 Array T3 Array X6726A StorEdge PCI Dual Fibre Channel Network Adapter X6731A GBIC Gigabit Interface Converter for the SBus FC 100 Host Adapter TABLE 2 1 Supported Hardware Part Number Description X978A 15m fiber optic cable X6746A Sun StorEdge FC switch 8 Switch SG XSW16 Sun StorEdge network FC switch 16 Switch 32P Guidelines for Configuration Hosts a Sun Enterprise 220 250 420 and 450 a Sun Enterprise 3x00 through Enterprise 6x00 a Sun Enterprise 10000 m Arrays Sun StorEdge A5200 array Sun StorEdge T3 array Sun StorEdge A3500FC array m Switches For High Availability Applications configure two switches in parallel m Zones maximum of four storage arrays per zone is possible with the Sun StorEdge A3500FC Array maximum of three storage arrays per zone is possible with the Sun StorEdge A5200 Array maximum of four devices per zone is possible with the Sun StorEdge T3 Array a Do not mix different arrays in the same zone A single zone can contain only A3500FC arrays or A5200 arrays or T3 arrays minimum of 2 ports per zone For example a 16 port switch can have a maximum of 8 zones For the maximum arrays and initiators per zone see TABLE 2 2 m All hosts connected to a zone must be of the same proce
5. vii Aufstellung von Sun Ger ten A A Achtung Um den zuverl ssigen Betrieb Ihres Sun Ger ts zu gew hrleisten und es vor berhitzung zu sch tzen d rfen die ffnungen im Ger t nicht blockiert oder verdeckt werden Sun Produkte sollten niemals in der N he von Heizk rpern oder Heizluftklappen aufgestellt werden Achtung Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000 betr gt 70Db A oder weniger Einhaltung der SELV Richtlinien Die Sicherung der I O Verbindungen entspricht den Anforderungen der SELV Spezifikation Anschlu des Netzkabels AN AN Achtung Sun Produkte sind f r den Betrieb an Einphasen Stromnetzen mit geerdetem Nulleiter vorgesehen Um die Stromschlaggefahr zu reduzieren schlie en Sie Sun Produkte nicht an andere Stromquellen an Ihr Betriebsleiter oder ein qualifizierter Elektriker kann Ihnen die Daten zur Stromversorgung in Ihrem Geb ude geben Achtung Nicht alle Netzkabel haben die gleichen Nennwerte Herk mmliche im Haushalt verwendete Verl ngerungskabel besitzen keinen berlastungsschutz und sind daher f r Computersysteme nicht geeignet Achtung Ihr Sun Ger t wird mit einem dreiadrigen Netzkabel f r geerdete Netzsteckdosen geliefert Um die Gefahr eines Stromschlags zu reduzieren schlie en Sie das Kabel nur an eine fachgerecht verlegte geerdete Steckdose an Die folgende Warnung gilt nur f r Ger te mit Wartezustand Net
6. Precauci n Con el producto Sun se proporciona un cable de alimentaci n con toma de tierra Para reducir el riesgo de descargas el ctricas con ctelo siempre a un enchufe con toma de tierra Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 La siguiente advertencia se aplica solamente a equipos con un interruptor de encendido que tenga una posici n En espera A Precauci n El interruptor de encendido de este producto funciona exclusivamente como un dispositivo de puesta en espera El enchufe de la fuente de alimentaci n est dise ado para ser el elemento primario de desconexi n del equipo El equipo debe instalarse cerca del enchufe de forma que este ltimo pueda ser f cil y r pidamente accesible No conecte el cable de alimentaci n cuando se ha retirado la fuente de alimentaci n del chasis del sistema Bater a de litio A Precauci n En las placas de CPU Sun hay una bater a de litio insertada en el reloj de tiempo real tipo SGS N m MK48T59Y MK48TXXB XX MK48T18 XXXPCZ M48T59W XXXPCZ o MK48T08 Las bater as no son elementos reemplazables por el propio cliente Pueden explotar si se manipulan de forma err nea No arroje las bater as al fuego No las abra o intente recargarlas Paquete de pilas A Precauci n Las unidades Sun StorEdge FC AL Switch contienen una pila de plomo sellada Productos de energ a port til n TLCO2V50
7. Existe riesgo de estallido si el paquete de pilas se maneja sin cuidado o se sustituye de manera indebida Las pilas s lo deben sustituirse por el mismo tipo de paquete de pilas de Sun Microsystems No las desmonte ni intente recargarlas fuera del sistema No arroje las pilas al fuego Des chelas siguiendo el m todo indicado por las disposiciones vigentes Tapa de la unidad del sistema Debe quitar la tapa del sistema cuando sea necesario a adir tarjetas memoria o dispositivos de almacenamiento internos Aseg rese de cerrar la tapa superior antes de volver a encender el equipo A Precauci n Es peligroso hacer funcionar los productos Sun sin la tapa superior colocada El hecho de no tener en cuenta esta precauci n puede ocasionar da os personales o perjudicar el funcionamiento del equipo Aviso de cumplimiento con requisitos de l ser Los productos Sun que utilizan la tecnolog a de l ser cumplen con los requisitos de l ser de Clase 1 Class 1 Laser Product Luokan 1 Laserlaite Klasse 1 Laser Apparat Laser KLasse 1 CD ROM A Precauci n El manejo de los controles los ajustes o la ejecuci n de procedimientos distintos a los aqu especificados pueden exponer al usuario a radiaciones peligrosas xiii GOST R Certification Mark Ur Nordic Lithium Battery Cautions Norge A Sverige A ADVARSEL Litiumbatteri Eksplosjonsfare Ved utskifting benyttes kun batteri som anbefalt av
8. machine namet xxii Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 Related Documentation Application Installer User s information GUI and User Installer User Troubleshooting Late news Software Late news Late news Late news Best Practices Late news Hub information Title Sun SANbox 8 Fibre Channel Switch Installer s User s Manual SANbox Segmented Loop Switch User s Manual SANbox 8 16 Segmented Loop Switch Management User s Manual Sun StorEdge network FC switch 8 and switch 16 Troubleshooting Guide Sun StorEdge network FC switch 8 and switch 16 Release Notes CDInsert Sun StorEdge A5000 Product Notes Sun StorEdge T3 Disk Tray Release Notes Sun StorEdge A3x00 A3500 FC Best Practices Guide Sun StorEdge A3500FC Release Notes Sun StorEdge FC 100 Hub Installation and Service Manual Part Number 875 1881 10 875 3059 10 875 3060 10 806 6923 10 806 6924 10 804 7491 10 805 1018 13 806 1497 12 806 6419 10 805 7758 11 805 0315 12 1 Check for the latest updates at http sunsolve sun com Also check http www sun com products n solu tions hardware docs Accessing Sun Documentation Online The docs sun com web site enables you to access select Sun technical documentation on the Web You can browse the docs sun com archive or search for a specific book title or subject at htt
9. may void the authority granted to the user by the FCC to operate this equipment XV ICES 003 Class A Notice Avis NMB 003 Classe A This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada ICES 003 Class B Notice Avis NMB 003 Classe B This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada VCCI TT xvi 232 AVCCI DT I FAA VCCIDKRNBDBI YIAF VaVBKUFT TV a AE Y DAA ME MEET CEDEX PHROHADKRIET DER BUZZEAR EMI l n VCCD DEEDS ITA A RELATE Ai Co COR EAR CHATS CERES ES EE ZT EE HVET COBRIIHMEA SAH TOG ET ok ERINA TENDEN ET 7973 B VCCI DT YFABVCCI DER WE 627 525 5822 BEUTI A MER 77 ABRAM TT CHSOMMICI FROHHMNKULET EUX RUE ETER ERT b ka VCC M RE EDI VIA Fe KATI COREL ARSE TER T2 EI ARAN EL TVEITA DEEMFTU APTVIEUSTRZERIIER LUTES NA A ERE ER TE ZIZEMBOET WRB MED TEL VRV RN ELT lt EIN Y Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 BSMI Class A Notice The following statement is applicable to products shipped to Ta wan and marked as Class A on the product compliance label GN BE HARA Saletan HAGEN BREER FF ESERIA FE HERFRA ERE SR EKG ENER xvii xviii Sun StorEdge network FC switch 8 and switch 16 Installat
10. D3 13 D2 O 13 D2 EEE 14 Dt 1112 14 D1 1108 15 CE eed 15 CE FIGURE 2 10 Controller Module FC AL ID Settings 16 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide April 2001 CHAPTER 3 Hardware Installation This chapter describes the procedures for installing the mounting rails for the 8 port switch and the mounting rails for the 16 port switch It describes the procedures for installing and cabling the switches with one or more Sun StorEdge A3500 FC Arrays one or more Sun StorEdge A5200 Arrays or one or more Sun StorEdge T3 Disk Trays It describes the procedure for installing the vent panel The differences between the 8 port and the 16 port switches are principally those in capacity and in the number and kinds of arrays you can connect Either switch functions with the Sun StorEdge A3500 FC Array a Sun StorEdge A5200 Array or a Sun StorEdge T3 array See Chapter 2 Configuration for valid configurations Some characteristics of the Sun StorEdge network FC switch 8 switch m You can install 22 Sun StorEdge network FC switch 8 switches in a Sun StorEdge Expansion Cabinet m You can install four Sun StorEdge network FC switch 8 switches per zone with a Sun StorEdge A3500 FC Array configuration a Sun StorEdge A3500 array and five Sun StorEdge D1000 trays m You can connect up to three Sun StorEdge A5200 Arrays per zone or up to four Sun Stor
11. Multiple StorEdge T3 Partner Pairs Using Switches Multi Host FIGURE 2 7 shows an example of a multi host configuration two hosts connected through fiber optic cables to two Sun StorEdge A3500FC controller modules using switches 10 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide April 2001 Sun StorEdge A3500FC controller modules Controller A FC AL port Host Controller B FC AL port SCSI x 5 Host adapter Switches B Host adapter eS A Drive tray x 5 Host V StorEdge A3500FC controller module A B Controller A FC AL port Controller B FC AL port SCSI x 5 Drive tray x 5 Host adapter Host adapter StorEdge A3500FC controller module Controller A FC AL port Controller B FC AL port SCSI x 5 gt Drive tray x 5 FIGURE 2 7 Two Hosts Connected to a Maximum of Four A3500FC Controller Modules Using Switches Chapter 2 Configurations 11 Note Different storage types may be attached on one switch so long as they are on different zones Each controller that is connected to a switch must have a unique loop ID Whenever you add a second controller to a switch make sure that the loop ID of the controller being connected is different from the loop ID of any other controller currently connected to the same switch Refer to Setting the Loop ID on page 15 for instructions on setting the
12. apparatfabrikanten Brukt batteri returneres apparatleverand ren VARNING Explosionsfara vid felaktigt batteribyte Anv nd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren Kassera anv nt batteri enligt fabrikantens instruktion Danmark A Suomi A xiv Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 ADVARSEL Litiumbatteri Eksplosionsfare ved fejlagtig h ndtering Udskiftning m kun ske med batteri af samme fabrikat og type Lev r det brugte batteri tilbage til leverandoren VAROITUS Paristo voi r j ht jos se on virheellisesti asennettu Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin H vit k ytetty paristo valmistajan ohjeiden mukaisesti Regulatory Compliance Statements Your Sun product is marked to indicate its compliance class e Federal Communications Commission FCC USA e Industry Canada Equipment Standard for Digital Equipment ICES 003 Canada e Voluntary Control Council for Interference VCCI Japan e Bureau of Standards Metrology and Inspection BSMI Taiwan Please read the appropriate section that corresponds to the marking on your Sun product before attempting to install the product FCC Class A Notice This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interfe
13. aux licences crites de Sun LA DOCUMENTATION EST FOURNIE EN L ETAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFA ON Od 192 Sa Adobe PostScript Declaration of Conformity Compliance Model Number Compliance ID SAN 008 Product Name Sun StorEdge network FC switch 16 EMC European Union This equipment complies with the following requirements of the EMC Directive 89 336 EEC EN55022 1998 CISPR22 1997 Class A EN55024 1998 EN61000 4 2 4 kV Direct 8 kV Air EN61000 4 3 3V m EN61000 4 4 1 0 kV AC Power Lines 0 5 kV Signal and DC Power Lines EN61000 4 5 1 kV AC Line Line and Outdoor Signal Lines 2kV AC Line Gnd 0 5 kV DC Power Lines EN61000 4 6 3 V EN61000 4 8 1 A m EN61000 4 11 Pass EN61000 3 2 1995 w Amendments 1 2 Pass EN61000 3 3 1995 Pass Safety This equipment complies with the following requirements of the Low Voltage Directive 73 23 EEC EC Type Examination Certificates EN60950 1992 2nd Edition Amendments 1 2 3 4 11 TUV Rheinland Certificate No AL 99 03 33778 IEC 950 1991 2nd Edition Amendments 1 2 3 4 Evaluated to all CB Countries CB Scheme Certificate No DE 3 5207 Supplementary Information This product was tested and complies
14. is almost identical to the procedure for the Sun StorEdge A3500 FC Array Run luxadm remove on Host A Run luxadm insert on Host B Chapter 4 Switch Activation 41 42 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 APPENDIX A Multiple Switches The Sun StorEdge Network FC Switch 2 0 GUI displays only one switch in the Fabric window display compared to Version 1 0 which displayed multiple switches in the Fabric window Managing Multiple Switches You must perform several operations to manage multiple Fabrics switches To Save a Switch Configuration to Disk In the Fabric window type the switch IP address in the IP Address field Click File and then Save As a Enter the Fabric name of the switch b Click the OK button The Fabric is saved to disk To Save a Subsequent Switch Configuration to Disk Click the gray Sun Icon to highlight the Fabric fields Click the Delete button The current Fabric field line disappears 43 3 Click in the IP Address field and type the new switch IP address 4 Click File and then Save As a Enter the Fabric name of the switch b Click the OK button The new switch Fabric is saved to disk v To Recall a Switch Configuration 1 Click File 2 Click Open Fabrics A Load from file pop up window displays all Fabrics with a fab extension 3 Click the Fabric you want to recall and Click OK T
15. the Fabric window enter the IP address of the switch in the IP Address Field SANSurfer finds the switch and a gray Sun icon is displayed in the status box If a red Sun icon is displayed in the Status box SANSurfer did not find the switch If the red Sun icon appears check the following 38 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 a Does the switch have power b Is the Ethernet cable plugged into the switch c Is the IP address on the switch the same as the IP address in the IP Address Field in SANSurfer When the gray Sun icon appears double click it The Topology window opens and the following message is displayed Before you can use Zoning you must change the stage type to SL Zoning Click the OK Enter the switch Faceplate window by double clicking the switch icon To Change the Stage Type In the Fabric window click the Stage Type button The default for this button is Hub single zone Click SL Zoning and then Apply The following message is displayed Modifying switch parameters may disrupt SAN traffic Do you want to continue Click the Yes button The following message is displayed Changing Chassis Type lt Hub lt gt Fabric requires a save to NV RAM and a switch reset to take effect Do you still wish to change Chassis Type Click the Yes button The following message is displayed Your po
16. 8 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 90900000000000000000000000000 Syma 0000000000000000000000000000 DU Y 0000000000000000000000000000 n 0000000000000000000000000000 No GBC g Port4 Porte Pots Porto g Port12 Port14 z Port16 Power 8 8 e 8 8 8 8 ST GBIC Port 1 Port 3 Port 5 Port 7 Port 9 Port 11 Port 13 Port 15 FIGURE 3 9 Sun StorEdge network FC switch 16 Switch Rear View 2 Install the GBIC See the Removal and Replacement Procedures chapter of the SANbox 8 16 Segmented Loop Switch User s Manual for instructions on installing a GBIC 3 Connect the fibre channel cables to the host bus adapters In the 16 port switch four groups are possible 1 Group 1 ports 1 4 2 Group 2 ports 5 8 3 Group 3 ports 9 11 4 Group 4 ports 12 16 Connect the host bus adapters to the first and the last ports of a zone For example in a four port zone connect the host bus adapters to ports 1 and 4 4 Connect the Fibre Channel cables to the storage arrays For example connect the cables in group 1 to ports 2 and 3 5 Use a tie wrap to secure the Fibre Channel cables as shown in FIGURE 3 12 and FIGURE 3 13 Chapter 3 Hardware Installation 29 Switch 1 Power co
17. Edge T3 Disk Trays per zone See Chapter 2 Configurations Some characteristics of the Sun StorEdge network FC switch 16 switch m You can install 18 Sun StorEdge network FC switch 16 switches in a Sun StorEdge Expansion Cabinet or four per zone with a Sun StorEdge A3500 FC Array configuration consisting of a Sun StorEdge A3500 array and five Sun StorEdge D1000 trays or three per zone with a Sun StorEdge A5200 Array or four per zone with a Sun StorEdge T3 array See Chapter 2 Configurations Refer to the Rackmount Placement Matrix available on docs sun com for hole positions in an expansion cabinet If you have a hub previously installed in your expansion cabinet you must remove it and the mounting tray prior to installing the switch and mounting rails Refer to the hub removal instructions in the Sun StorEdge FC 100 Hub Installation and Service Manual which is packaged with the hub Installing the Mounting Rails The 8 port switch comes with a set of mounting rails that holds two switches The 16 port switch comes with individual rails for each switch This section describes how to attach the mounting rails to an expansion cabinet for two switch and four switch configurations Installing the Mounting Rails for 8 Port Switches V To Install the Rails for Two 8 port Switches 1 Loosely start two stopper screws into each rail while they remain out of the cabinet see FIGURE 3 2 2 Working from the back of the cabinet
18. GURE 3 12 for J8 location Connect the Y cable to J8 on both sequencers Replace the side vent panel From the front push the lowest A5200 array back into place Connect one end of the left Y cable to the lowest switch Connect the other end to the next switch If there are four switches connect one end of the right Y cable to the third switch Connect the other end to the highest switch From the back of the cabinet follow the route of the existing cables to the sides and up the rear of the cabinet to the level of the switches The Y cable on the back sequencer routes up the right side The Y cable on the front sequencer routes up the left side Use tie wraps as necessary to secure the cables Connecting and Routing the Cables for a Sun StorEdge A3500FC Array When you have the switch es vent and filler panels in place you must connect and route the cables If the existing power cords are too short replace them with the Y cable Working from the back connect the power cord s See FIGURE 3 8 FIGURE 3 9 and FIGURE 3 10 Allow the power cord to dangle temporarily GBIC BY92999009 Port 2 Port 4 Port 6 Port 8 H000000000 eL i i i 0000000000 on 33 i i Port 7 Port 1 Port 3 Port 5 GBIC Power FIGURE 3 8 Sun StorEdge network FC switch 8 Switch Rear View 2
19. Guide December 2000 FIGURE 3 4 Installing Four 8 Port Switches Into the Mounting Rails Installing a 16 Port Switch v To Install the Switch 1 From the front of the cabinet slide the first switch into the lowest of the mounting rails The GBIC side goes toward the back of the rack The switch casing stops moving when it meets the front rail 2 Insert the front lockdown screws 3 Tighten the stoppers Chapter 3 Hardware Installation 23 Installing the Vent Panel Sun StorEdge network FC switch 8 Switch The procedure for installing the vent panel varies with your configuration a If you have a two switch configuration install one vent panel and one 2 U filler panel m If you have a four switch configuration install two vent panels No filler panel is necessary 1 U Filler Panel FIGURE 3 5 Installing the Vent Panel The Two Switch 8 port Configuration 24 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 v To Install the Vent Panel on the Two Switch Configuration 1 Mount the vent panel over the front of each set of two switches 2 Mount the filler panel above the vent panel and below the existing 2 U filler panel 3 Tighten the captive screws ST TT TITTET
20. Sun microsystems Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide Version 2 0 2 1 Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 U S A 650 960 1300 Part No 806 6922 11 June 2001 Revision A Send comments about this document to docfeedback sun com Copyright 2001 Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 U S A All rights reserved This product or document is distributed under licenses restricting its use copying distribution and decompilation No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Parts of the product may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo AnswerBook2 docs sun com Sun StorEdge Sun Enterprise Java and Solaris are trademarks registered trademarks or service marks of Sun Microsystems Inc in the U S and other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and other countries Products bearing SPARC trademarks are based upon an architecture develo
21. TP or the management GUI to change the IP address See the Sun Switch Management Installer s User s Manual Turn the switch power off and then back on Chapter 4 Switch Activation 35 8 Verify the switch IP address ping lt ip_address gt For example ping 192 129 122 111 Installing the Sun StorEdge Network FC Switch 2 0 GUI The Sun StorEdge FC Switch 2 0 GUI application is supported on JDK 1 2 2_05a and later Refer to the CD documentation 804 7287 10 packaged with the system for instructions Upgrading the GUI If Sun StorEdge FC Switch 1 0 Version 2 06 16 GUI has been installed in the system you must perform a package removal before you install the Sun StorEdge FC Switch 2 0 GUI Y Removing the 1 0 GUI 1 In the root directory type pkgrm SUNWsmgr The following message is displayed The following package is currently installed SUNWsmgr SANSurfer Zlogic Fibre Channel Administration i86pc sparc 2 06 16 Do you want to remove this package 36 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 2 Type y Yes The following message is displayed Removing installed package instance lt SUNWsmgr gt Verifying package dependencies Processing package information Removing pathnames in class lt none gt usr opt SUNWsmgr bin esm_smgr usr opt SUNWsmgr bin Sun jar usr opt SUNWsmgr bin u
22. areil m Ne jamais introduire d objets quels qu ils soient dans une des ouvertures de l appareil Vous pourriez vous trouver en pr sence de hautes tensions dangereuses Tout objet conducteur introduit de la sorte pourrait produire un court circuit qui entra nerait des flammes des risques d lectrocution ou des d g ts mat riels Symboles Vous trouverez ci dessous la signification des diff rents symboles utilis s Attention risques de blessures corporelles et de d g ts mat riels Veuillez suivre les instructions Evitez le contact La temp rature des surfaces est lev e et leur contact peut provoquer des blessures corporelles i Attention surface temp rature lev e Attention pr sence de tensions dangereuses Pour viter les risques d lectrocution et de danger pour la sant physique veuillez suivre les instructions MARCHE Votre syst me est sous tension courant alternatif Un des symboles suivants sera peut tre utilis en fonction du type d interrupteur de votre syst me courant alternatif O ARRET Votre syst me est hors tension VEILLEUSE L interrupteur Marche Veilleuse est en position Veilleuse Modification du mat riel Ne pas apporter de modification m canique ou lectrique au mat riel Sun Microsystems n est pas responsable de la conformit r glementaire d un produit Sun qui a t modifi Positionnem
23. ch 16 hardware and configure it to the network It provides information and pointers to additional documentation you may need for configuring troubleshooting and using the switch The book is intended for technical users who have experience with storage systems Using UNIX Commands This document may not contain information on basic UNIX commands and procedures such as shutting down the system booting the system and configuring devices See one or more of the following for this information m Solaris Handbook for Sun Peripherals m AnswerBook2 online documentation for the Solaris operating environment m Other software documentation that you received with your system xxi Typographic Conventions Typeface AaBbCc123 AaBbCc123 AaBbCc123 Meaning The names of commands files and directories on screen computer output What you type when contrasted with on screen computer output Book titles new words or terms words to be emphasized Command line variable replace with a real name or value Shell Prompts Shell C shell C shell superuser Bourne shell and Korn shell Bourne shell and Korn shell superuser Examples Edit your login file Use 1s a to list all files 2 You have mail 2 SU Password Read Chapter 6 in the User s Guide These are called class options You must be superuser to do this To delete a file type rm filename Prompt machine name
24. d en los equipos Sun modificados Ubicaci n de un producto Sun xii A A Precauci n Para asegurar la fiabilidad de funcionamiento de su producto Sun y para protegerlo de sobrecalentamien tos no deben obstruirse o taparse las rejillas del equipo Los productos Sun nunca deben situarse cerca de radiadores o de fuentes de calor Precauci n De acuerdo con la norma DIN 45 635 Parte 1000 se admite un nivel de presi n ac stica para puestos de trabajo m ximo de 70Db A Cumplimiento de la normativa SELV El estado de la seguridad de las conexiones de entrada salida cumple los requisitos de la normativa SELV Conexi n del cable de alimentaci n el ctrica A A A Precauci n Los productos Sun est n dise ados para trabajar en una red el ctrica monof sica con toma de tierra Para reducir el riesgo de descarga el ctrica no conecte los productos Sun a otro tipo de sistema de alimentaci n el ctrica P ngase en contacto con el responsable de mantenimiento o con un electricista cualificado si no est seguro del sistema de alimentaci n el ctrica del que se dispone en su edificio Precauci n No todos los cables de alimentaci n el ctrica tienen la misma capacidad Los cables de tipo dom stico no est n provistos de protecciones contra sobrecargas y por tanto no son apropiados para su uso con computadores No utilice alargadores de tipo dom stico para conectar sus productos Sun
25. e Ne le d montez pas et n essayez pas de le recharger hors du syst me Ne faites pas br ler la batterie mais mettez la au rebut conform ment aux r glementations locales en vigueur Attention Les unit s Sun StorEdge FC AL Couvercle Pour ajouter des cartes de la m moire ou des unit s de stockage internes vous devrez d monter le couvercle de l unit systeme Sun Ne pas oublier de remettre ce couvercle en place avant de mettre le syst me sous tension Attention il est dangereux de faire fonctionner un produit Sun sans le couvercle en place Si l on n glige cette pr caution on encourt des risques de blessures corporelles et de d g ts mat riels Conformit aux certifications Laser Les produits Sun qui font appel aux technologies lasers sont conformes aux normes de la classe 1 en la mati re Class 1 Laser Product Luokan 1 Laserlaite Klasse 1 Laser Apparat Laser KLasse 1 CD ROM r glages ou de performances de proc dures autre que celle sp cifi e dans le pr sent document peut provoquer une exposition des radiations dangereuses Attention L utilisation de contr les de Normativas de seguridad El siguiente texto incluye las medidas de seguridad que se deben seguir cuando se instale alg n producto de Sun Microsystems Precauciones de seguridad Para su protecci n observe las siguientes medidas de seguridad cuando manipule su equipo m Siga todas los avisos e ins
26. ent d un produit Sun A A Attention pour assurer le bon fonctionnement de votre produit Sun et pour l emp cher de surchauffer il convient de ne pas obstruer ni recouvrir les ouvertures pr vues dans l appareil Un produit Sun ne doit jamais tre plac proximit d un radiateur ou d une source de chaleur Attention Le niveau de pression acoustique au poste de travail s l ve selon la norme DIN 45 635 section 1000 a 70 dB A ou moins Conformit SELV S curit les raccordements E S sont conformes aux normes SELV Connexion du cordon d alimentation A Attention les produits Sun sont con us pour fonctionner avec des alimentations monophas es munies d un conducteur neutre mis la terre Pour carter les risques d lectrocution ne pas brancher de produit Sun dans un autre type d alimentation secteur En cas de doute quant au type d alimentation lectrique du local veuillez vous adresser au directeur de l exploitation ou un lectricien qualifi A Attention tous les cordons d alimentation n ont pas forc ment la m me puissance nominale en mati re de courant Les rallonges d usage domestique n offrent pas de protection contre les surcharges et ne sont pas pr vues pour les syst mes d ordinateurs Ne pas utiliser de rallonge d usage domestique avec votre produit Sun Attention votre produit Sun a t livr quip d un cordon d alimentation 4
27. ers file by adding the MAC address and switch name For example 8 0 20 7d 93 7e switch name 34 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 In this example m 8 0 20 7d 93 7e is the MAC address m switch name is the name of the switch you are installing Edit the etc hosts file with the IP address and switch name For example 192 129 122 111 switch_name In this example 192 129 122 111 is the assigned IP address Edit the etc nsswitch conf file to reference the local system files To ensure that the Solaris software environment uses the changes made to etc ethers and etc hosts files edit the host and ethers entries in the etc nsswitch conf file so that the files parameter appears before the NOTFOUND return statements nis files NOTFOUND return nis files NOTFOUND return Determine whether the RARP daemon is running by typing ps eaf grep rarpd If RARP is not running start the RARP daemon in the Solaris software environment by typing usr sbin in rarpd a amp The IP address will automatically download to the switch after you install the switch and power on the system Note RARP might not work properly if you have connected the ethernet port of the FC switch to an ethernet switch this is due to the long time it might take for the ethernet switch to transmit the RARP In such a case you can use TF
28. ersonal injury if touched Caution Hot surface Avoid contact reduce the risk of electric shock and danger to Caution Hazardous voltages are present To personal health follow the instructions On Applies AC power to the system Depending on the type of power switch your device has one of the following symbols may be used O Off Removes AC power from the system Standby The On Standby switch is in the standby position Modifications to Equipment Do not make mechanical or electrical modifications to the equipment Sun Microsystems is not responsible for regulatory compliance of a modified Sun product Placement of a Sun Product of your Sun product Never place a Sun product near a radiator or heat register Failure to follow these guidelines can cause overheating and affect the reliability of your Sun product Caution Do not block or cover the openings Caution The workplace dependent noise level defined in DIN 45 635 Part 1000 must be 70Db A or less SELV Compliance Safety status of I O connections comply to SELV requirements Power Cord Connection A A A Caution Sun products are designed to work with single phase power systems having a grounded neutral conductor To reduce the risk of electric shock do not plug Sun products into any other type of power system Contact your facilities manager or a qualified electrician if you are not sure what t
29. gie relative aux polices de caract res est prot g par un copyright et licenci par des fournisseurs de Sun Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun AnswerBook2 docs sun com Sun StorEdge Sun Enterprise Javaet Solarissont des marques de fabrique ou des marques d pos es ou marques de service de Sun Microsystems Inc aux Etats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox pour la recherche et le d veloppement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une licence non exclusive de Xerox sur l interface d utilisation graphique Xerox cette licence couvrant galement les licenci s de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment
30. he new Selected Fabric has been added v To Delete a Switch Configuration 1 Click File 2 Click Delete Fabrics File 3 Highlight the Fabric you want to delete 4 Click OK The Fabric is deleted 44 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000
31. ion and Configuration Guide December 2000 Contents Installation Overview 1 Overview 1 Configurations 3 Supported Hardware Configurations 3 Guidelines for Configuration 4 Single Host Connected to One Controller 5 Single Host Connected to Multiple Controller Modules Using Switches 7 Multi Host 10 Setting the Loop ID 15 Hardware Installation 17 Installing the Mounting Ra ls 18 Installing the Mounting Rails for 8 Port Switches 18 Installing the Mounting Rails for 16 Port Switches 20 Installing the 8 Port Switch 22 Installing a 16 Port Switch 23 Installing the Vent Panel 24 Sun StorEdge network FC switch 8 Switch 24 Sun StorEdge network FC switch 16 Switch 26 Contents xix Installing Connecting and Routing the Cables 26 Installing the Y cables in a Resident Cabinet 27 Connecting and Routing the Cables for a Sun StorEdge A3500FC Array 28 4 Switch Activation 33 Configuring the Switch Ethernet Port 33 RARP 33 Installing the Sun StorEdge Network FC Switch 2 0 GUI 36 Upgrading the GUI 36 Installing the 2 0 GUI 37 Setting the Stage Type 38 Re zoning and Moving A3500FC LUNs from Host A to Host B 40 A Multiple Switches 43 Managing Multiple Switches 43 xx Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 Preface The Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide describes how to set up the Sun StorEdge network FC switch 8 and swit
32. ishandled or incorrectly replaced Replace only with the same type of Sun Microsystems battery pack Do not disassemble it or attempt to recharge it outside the system Do not dispose of the battery in fire Dispose of the battery properly in accordance with local regulations System Unit Cover You must remove the cover of your Sun computer system unit to add cards memory or internal storage devices Be sure to replace the top cover before powering on your computer system A Caution Do not operate Sun products without the top cover in place Failure to take this precaution may result in personal injury and system damage vi Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 Laser Compliance Notice Sun products that use laser technology comply with Class 1 laser requirements Class 1 Laser Product Luokan 1 Laserlaite Klasse 1 Laser Apparat Laser KLasse 1 CD ROM the performance of procedures other than those specified herein may result in hazardous radiation exposure Caution Use of controls adjustments or Einhaltung sicherheitsbeh rdlicher Vorschriften Auf dieser Seite werden Sicherheitsrichtlinien beschrieben die bei der Installation von Sun Produkten zu beachten sind Sicherheitsvorkehrungen Treffen Sie zu Ihrem eigenen Schutz die folgenden Sicherheitsvorkehrungen wenn Sie Ihr Ger t installieren m Beachten Sie alle auf den Ger ten a
33. loop ID of a controller Caution Ensure that the controller modules are not connected to the same switch Caution All hosts on a zone must be of the same processor family See Guidelines for Configuration on page 4 12 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide April 2001 Sun StorEdge A5200 controller modules 3 Host itch Host adapter switches J Host adapter il Host Host adapter Host adapter IBB OU FIGURE 2 8 Example Two Hosts Connected to Three StorEdge A5200 Controller Modules Using Switches Chapter 2 Configurations 13 Sun StorEdge T3 Partner Pairs 4 po Host Host adapter Host adapter Switches p EA E 33 Host Bio FIGURE 2 9 Example Two Hosts Connected to Four StorEdge T3 Partner Pairs Using Switches 14 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide April 2001 Setting the Loop ID Setting the loop ID of the Sun StorEdge A3500 FC controller is different from the procedure for the Sun StorEdge A5200 array and for the Sun StorEdge T3 array To Set the Loop ID of a Sun StorEdge A3500 FC Controller This section explains how to set the loop ID of a Sun StorEdge A3500 FC controller that is connected to a switch Tools and equipment needed m Needle nose pliers
34. loosely start two screws into the cabinet rails See FIGURE 3 2 See the on line Rackmount Placement Matrix for the hole locations of your configuration 3 Working from the front of the cabinet install the side rails by sliding the slot in the rail onto the screw Note The rails for left and right are identical but reversed for the two sides The large hole is oriented near the back for both rails Use the slot marked L for the left rail Use the slot marked R for the right rail 18 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 FIGURE 3 1 Detail of Rail Showing Slots Install three 10 32 screws on each rail Tighten the fourth screw To Install Four Switches Mount the first two switches See To Install the Rails for Two 8 port Switches on page 18 Loosely start two stopper screws into each rail see FIGURE 3 2 Working from the back of the cabinet loosely start two screws for the mounting rails into the cabinet see FIGURE 3 2 See the on line Rackmount Placement Matrix for the correct screw holes for your configuration Working from the front of the cabinet install the side rails by sliding the slot in each rail onto the screw see FIGURE 3 1 The large hole is oriented near the rear for both rails Use the slot marked L for the left rail Use the slot marked R for the right rail Chapter 3 Hardware Installation 19
35. m For information about the Sun StorEdge T3 Disk Tray refer to the documentation that came with the array Unplug the power cord from both fan trays and the J12 connections on both sequencers See FIGURE 3 12 for the J12 location From the back of the cabinet follow the route of the existing cables to the sides and up the rear of the cabinet to the level of the switches The Y cable on the back sequencer routes up the right side The Y cable on the front sequencer routes up the left side Use tie wraps as necessary to secure the cables Connect the Y cable on right side to the right side of the fan tray and the right side of number 8 T3 Connect the Y cable on the left side to the left side of the fan tray and the left side of number 8 T3 Connect the existing R8 cable to the lowest switch Connect the existing L8 cable to the highest switch Sun StorEdge A5200 Array Replacing the Power Cable with the Y cable If the existing power cords are too short replace them with the Y cable Power off the system For information about the Sun StorEdge A5200 Array refer to the documentation that came with the array Remove the lower vented side panel from the right side Chapter 3 Hardware Installation 27 Working from the back push the lowest A5200 array about eight inches toward the front of the cabinet This will allow you access to the cables Disconnect the power cord from J8 on both sequencers See FI
36. m Jumpers supplied with the StorEdge A3500 A3500FC unit m Antistatic wrist strap Every device attached to a SCSI or FC AL bus must have a unique controller module ID number in order to communicate The factory default ID settings for controller A and B are ID 5 and ID 4 respectively Caution Do not configure more than four controller modules on the same loop Locate the 16 pins on the rear of the FC AL controller module FIGURE 2 10 The eight pins on the right determine the host ID for controller 1 A the pins on the left determine the ID for controller 2 B Wearing the antistatic wrist strap install jumpers on the pins as shown in FIGURE 2 10 If necessary use the needlenose pliers to remove the jumpers To Verify the Loop ID of the Sun StorEdge A5200 and T3 Arrays Be sure each array on a single loop has a unique target ID If two Sun StorEdge T3 arrays have the same target ID on the same FC AL loop the software does not recognize their presence Chapter2 Configurations 15 Controller B Controller A Controller B p 00000000 Controller A ID AL 20000000 ID AL 8421 Dec PA 8421 8421 8421 Dec PA gc 3308 e see E RC BIE SIGE no SC REIG SERRE e fol el fol 5 am BIE CEE 7 SHE gt ee 8 D9 er 8 D9 oe 9 D6 00 9 D6 bh 10 DS 2 10 Ds O 11 D4 O 11 D4 HEP 12 D3 e 12
37. may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio television technician for help Shielded Cables Connections between the workstation and peripherals must be made using shielded cables in order to maintain compliance with FCC radio frequency emission limits Networking connections can be made using unshielded twisted pair UTP cables Modifications Any modifications made to this device that are not approved by Sun Microsystems Inc
38. ngebrachten Warnhinweise und Anweisungen m Vergewissern Sie sich da Spannung und Frequenz Ihrer Stromquelle mit der Spannung und Frequenz bereinstimmen die auf dem Etikett mit den elektrischen Nennwerten des Ger ts angegeben sind m Stecken Sie auf keinen Fall irgendwelche Gegenst nde in ffnungen in den Ger ten Leitf hige Gegenst nde k nnten aufgrund der m glicherweise vorliegenden gef hrlichen Spannungen einen Kurzschlu verursachen der einen Brand Stromschlag oder Ger teschaden herbeif hren kann Symbole Die Symbole in diesem Handbuch haben folgende Bedeutung Ger teschaden Befolgen Sie die Anweisungen Achtung Gefahr von Verletzung und beriihren da Verletzungsgefahr durch heifse 4 Achtung Hohe Temperatur Nicht Oberflache besteht Achtung Gef hrliche Spannungen Anweisungen befolgen um Stromschlage und Verletzungen zu vermeiden Ein Setzt das System unter Wechselstrom Je nach Netzschaltertyp an Ihrem Ger t kann eines der folgenden Symbole benutzt werden Aus Unterbricht die Wechselstromzufuhr O zum Gerat Wartezustand Stand by Position Der Ein Wartezustand Schalter steht auf Wartezustand nderungen an Sun Ger ten Nehmen Sie keine mechanischen oder elektrischen nderungen an den Ger ten vor Sun Microsystems bernimmt bei einem Sun Produkt das ge ndert wurde keine Verantwortung f r die Einhaltung beh rdlicher Vorschriften
39. o Q o rn v o MK o Re Al gt lt al IT A UZ N T NS 24 lhe I o ZA Z IVC EN le Ze bl a A o SS cd o P lt RE NAT ET fv A Gg Mi Za st Pag Als a 7 r ex E A 7 L e N A LT p i o lt oa ra o G7 o LZA oo 27 gt o gt o Pg aT o A Preinstalled screws 7 N FIGURE 3 3 Installing the rails for a 16 port Sun StorEdge network FC switch 16 Switch Installing the Mounting Rails Working from the front of the cabinet install the side rails by sliding the keyhole slot in the rail onto the screw Note Install the lower rail in a two switch configuration before the upper one Chapter 3 Hardware Installation 21 2 Insert the remaining screws through the mounting rail into the cabinet rail Do not tighten any of the screws until you have them all loosely started 3 Tighten all the screws when all four screws in each bracket are in place The order of tightening does not matter Installing the 8 Port Switch v To Install the Switch 1 From the front of the cabinet slide the first switch into the lowest of the mounting rails The GBIC GigaBit Interface Converter side goes toward the back of the rack The switch casing stops moving when it meets the stopper screw on the mounting rail 2 Insert the front lockdown screws see FIGURE 3 4 3 Tighten the stoppers 22 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration
40. p docs sun com Preface xxiii Ordering Sun Documentation Fatbrain com an Internet professional bookstore stocks select product documentation from Sun Microsystems Inc For a list of documents and how to order them visit the Sun Documentation Center on Fatbrain com at http www fatbrain com documentation sun Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions You can email your comments to Sun at docfeedback sun com Please include the part number 806 6923 10 of your document in the subject line of your email xxiv Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 CHAPTER 1 Installation Overview This chapter contains an overview of the tasks required for installing the Sun StorEdge network FC switch 8 and switch 16 switch and provides references to the documentation for configuring and using the switch Overview The following provides the major steps for installing either the 8 port or 16 port switch hardware and software Confirm the switch firmware and GUI revision level for your switch Instructions are provided in the Release Notes Select the area for the expansion cabinet onto which you plan to install the switch Be sure to allow for the minimum airflow temperature and power restrictions See the Sun Switch Management Installer s User s Manual for instruc
41. ped by Sun Microsystems Inc The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements Federal Acquisitions Commercial Software Government Users Subject to Standard License Terms and Conditions DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2001 Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 Etats Unis Tous droits r serv s Ce produit ou document est distribu avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit ou document ne peut tre reproduite sous aucune forme par quelque moyen que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y en a Le logiciel d tenu par des tiers et qui comprend la technolo
42. rds Switch 2 Switch 3 Switch 4 ll FIGURE 3 10 Power Connection for Two or Four Switches J12 J8 FIGURE 3 11 Power Sequencer 30 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 Tie wrap Extension power cord FIGURE 3 12 Example of Cable Routing for the 8 port Switch FIGURE 3 13 Example of Cable Routing for the 16 port Switch Note Connections to storage arrays are not shown in these figures Chapter 3 Hardware Installation 31 32 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 CHAPTER 4 Switch Activation This chapter contains the procedures for bringing the new Sun StorEdge FC Switch 2 0 software onto the network Configuring the Switch Ethernet Port The IP address of a switch shipped from manufacturing is set to the default value of 10 0 0 1 This default IP address can be set or changed using the Reverse Address Resolution Protocol RARP Trivial File Transfer Protocol TETP or the switch management GUI RARP You can use RARP to set the address when you first receive the switch or if you forget the switch IP address Note To set the IP address using the TFTP or GUI methods see Chapter 2 in the Sun Switch Management Installer s User s Manual The Sun StorEdge FC Switch 2 0 RARP feature a
43. rence 2 This device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded Cables Connections between the workstation and peripherals must be made using shielded cables to comply with FCC radio frequency emission limits Networking connections can be made using unshielded twisted pair UTP cables Modifications Any modifications made to this device that are not approved by Sun Microsystems Inc may void the authority granted to the user by the FCC to operate this equipment FCC Class B Notice This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that
44. rt changes have been applied to the switch Do you want to save these changes in non volatile memory Chapter 4 Switch Activation 39 5 Click the Yes button The switch resets and the SANSurfer screen displays the Fabric window Re zoning and Moving A3500FC LUNs from Host A to Host B Before you can rezone a few procedures are necessary v To Rezone From Host A 1 Stop all activity to the A3500FC LUNs 2 Stop RM 6 22 Type etc init d rdacctrol stop 3 Unmount any A3500FC LUNs from etc vfstab 4 Deport any VM Disk Groups The system is ready for rezoning You can move the A3500FC LUNs from Host A to Host B 5 Run etc init d rdacctrl config 6 If necessary run etc init d rdacctrol start v To Rezone From Host B 1 If RM 6 22 has been installed run the hot_add command If RM 6 22 has not been installed you must install it and run several commands a Install the RM 6 22 software b Run the following commands f etc init d rdacctrl stop etc init d rdacctr config etc init d rdacctr start 40 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 Import any VM Disk Groups Mount any VM Volumes in etc vfstab It may be necessary to run fsck To Rezone and Move StorEdge A5200 or Sun StorEdge T3 LUNs from Host A to Host B The procedure for rezoning and moving the Sun StorEdge A5200 Array and Sun StorEdge T3 Disk Trays
45. s about setting the loop ID of a controller Caution Be sure that the controller module of the A3500 FC array is split between two switches For example connect controller A to switch 1 and controller B to switch 2 Chapter 2 Configurations 7 8 Sun StorEdge A3500FC controller module Controller A FC AL port Controller B FC AL port SCSI x 5 gt Drive tray x 5 bl Host Switches Host adapter StorEdge A3500FC controller module Host adapter Controller A FC AL port Controller B FC AL port SCSIx 5 i Drive tray x 5 e e e StorEdge A3500FC controller module Controller A FC AL port Controller B FC AL port gt Drive tray x 5 SCSIx5 FIGURE 2 4 Example Single Host Connected to Multiple A3500FC Controller Modules Using Switches Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide April 2001 Sun StorEdge A5200 controller modules 3 Host Host adapter EN Host adapter Switches FIGURE 2 5 Example Single Host Connected to Multiple A5200 Controller Modules Using switches Chapter2 Configurations 9 Sun StorEdge T3 Partner Pairs 4 EH Host Switches mm L Host adapter t Host adapter y E3 FIGURE 2 6 Example Single Host Connected to
46. sr opt SUNWsmgr app dat usr opt SUNWsmgr lt non emty directory not removed gt Updating system information Removal os lt SUNWsmgr gt was successful Installing the 2 0 GUI Adding the GUI package e Type pkgadd d SUNWsmgr Starting the GUI You may start the GUI in two ways Use the Java command line For the first method type java jar usr opt SUNWsmgr bin esm_smgr Chapter 4 Switch Activation 37 For the second method install and bring up Component Manager 2 1 Click the Launch button See the Component Manager documentation that came with your software for more details on how to install and use Component Manager The login window appears If this is the first time this switch has been logged into or if no username and password file have been created by a superuser use the default username and password which is su for each one Otherwise use the username and password assigned during a previous session ESTA mi HER DRE Setting the Stage Type After installing the GUI you must set the stage type to SL Zoning Split Loop SL zones allow you to divide the SL ports into multiple zones that define which ports will communicate with each other Communications occur only between ports in the defined SL zone The switches are shipped from the factory set to Hub mode SL mode This stage type must to be changed to SL Zoning v To Change Hub Single Zone to SL Zoning 1 In
47. ssor family for example Enterprise 10000 or Enterprise 3x00 6x00 or Enterprise 220 250 420 450 4 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide April 2001 You can dynamically add storage to a zone using luxadm procedures for the Sun StorEdge A5200 and T3 arrays Do not dynamically remove storage TABLE 2 2 Arrays Zones and Initiators Array Maximum Arrays Zone Maximum Initiators Zone A3500FC 4 2 A5200 3 2 initiators per loop or a maximum of four per array i T3 4 2 TABLE 2 3 Dynamic Addition to a Zone ADD Array First Additional A3500FC No Yes A5200 Yes Yes T3 Yes Yes Single Host Connected to One Controller FIGURE 2 1 shows one host connected through fiber optic cables to one Sun StorEdge A3500FC controller module using switches Each controller module has two Fibre Channel ports FIGURE 2 2 shows one host connected through fiber optic cables to one Sun StorEdge A5200 controller module using switches Each controller module has two Fibre Channel ports FIGURE 2 3 shows one host connected through fiber optic cables to one Sun StorEdge T3 partner pair using switches Note No other type of Fibre Channel storage should share the same zone connected to the Sun StorEdge A3500FC controller module Chapter 2 Configurations 5 6 Host Switch Sun StorEdge A3500FC controller module Host adapter Host adapter Controller A FC AL port
48. tions Verify the configuration for your system Supported configurations are detailed in Chapter 2 Configuration Install the GBICs See the Sun Switch Management Installer s User s Manual for the 8 port switch or the SANbox Segmented Loop Switch User s Manual for instructions Install the vent panel See Installing the Vent Panel on page 24 Connect the cables and power cords See Chapter 2 Configuration for configuration information See also Installing Connecting and Routing the Cables on page 26 7 Configure the switch for the network See Chapter 4 Switch Activation for information on configuring the switch to the network 8 Install the SANSurfer 2 0 application See Installing the Sun StorEdge Network FC Switch 2 0 GUI on page 36 for information on installing the GUI application 2 Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 CHAPTER 2 Configurations Supported Hardware Configurations Each switch is connected to the host through a fiber optic cable to a Sun StorEdge PCI Dual Fibre Channel Network Adapter The other end of the switch is connected to storage devices through a fiber optic cable TABLE 1 lists supported hardware including part numbers and a brief description of each item Note The maximum length supported for a fibre optic cable is 500m TABLE 2 1 Supported Hardware
49. trois fils avec prise de terre Pour carter tout risque d lectrocution branchez toujours ce cordon dans une prise mise la terre L avertissement suivant s applique uniquement aux syst mes quip s d un interrupteur VEILLEUSE A Attention le commutateur d alimentation de ce produit fonctionne comme un dispositif de mise en veille uniquement C est la prise d alimentation qui sert mettre le produit hors tension Veillez donc installer le produit proximit d une prise murale facilement accessible Ne connectez pas la prise d alimentation lorsque le ch ssis du systeme n est plus aliment Batterie au lithium A Attention sur les cartes CPU Sun une batterie au lithium r f rence MK48T59Y MK48TXXB XX MK48T18 XXXPCZ M48T59W XXXPCZ ou MK48T08 a t moul e dans l horloge temps r el SGS Les batteries ne sont pas des pi ces remplacables par le client Elles risquent d exploser en cas de mauvais traitement Ne pas jeter la batterie au feu Ne pas la d monter ni tenter de la recharger x Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 Bloc batterie Switch contiennent une batterie tanche au plomb produits nerg tiques portatifs n TLC02V50 Il existe un risque d explosion si ce bloc batterie est manipul de fa on erron e ou mal mis en place Ne remplacez ce bloc que par un bloc batterie Sun Microsystems du m me typ
50. trucciones marcados en el equipo m Aseg rese de que el voltaje y la frecuencia de la red el ctrica concuerdan con las descritas en las etiquetas de especificaciones el ctricas del equipo m No introduzca nunca objetos de ning n tipo a trav s de los orificios del equipo Pueden haber voltajes peligrosos Los objetos extra os conductores de la electricidad pueden producir cortocircuitos que provoquen un incendio descargas el ctricas o da os en el equipo S mbolos En este libro aparecen los siguientes s mbolos personales y da os al equipo Siga las Precauci n Existe el riesgo de lesiones instrucciones Precauci n Superficie caliente Evite el contacto Las superficies est n calientes y pueden causar da os personales si se tocan xi A Precauci n Voltaje peligroso presente Para reducir el riesgo de descarga y da os para la salud siga las instrucciones Encendido Aplica la alimentaci n de CA al sistema Seg n el tipo de interruptor de encendido que su equipo tenga es posible que se utilice uno de los siguientes s mbolos O D Apagado Elimina la alimentaci n de CA del sistema En espera El interruptor de Encendido En espera se ha colocado en la posici n de En espera Modificaciones en el equipo No realice modificaciones de tipo mec nico o el ctrico en el equipo Sun Microsystems no se hace responsable del cumplimiento de las normativas de segurida
51. utomatically downloads the assigned IP address to the switch After you cable the disk tray and power on your system the IP address is automatically assigned Before you begin make sure you have the following information IP address Contact the person who maintains your network for this information MAC address See FIGURE 4 1 and FIGURE 4 2 for the location 33 of the MAC Address Switch name This is the assigned name of the switch you are installing 0000000000 C at FIGURE 4 1 Sun StorEdge FC switch 8 Switch Rear View MAC Address 0000000000000000000000000000 a o o 00 oo 00 oo 00 oo 00 oo o o o Q o o o O MAC Address FIGURE 4 2 Sun StorEdge network FC switch 16 Switch Rear View v To Set the Network IP Address For the Switch 1 On a host connected to the same subnet as the switch save your current configuration to a file by typing cp p etc ethers etc ethers SAV cp p etc nsswitch conf etc nsswitch conf SAV cp p etc hosts etc hosts SAV 2 On a host connected to the same subnet as the switch edit the etc eth
52. with all the requirements for the CE Mark S S Dennis P Symanski DATE Peter Arkless DATE Manager Compliance Engineering Quality Manager Sun Microsystems Inc Sun Microsystems Scotland Limited 901 San Antonio Road MPK15 102 Springfield Linlithgow Palo Alto CA 94303 4900 U S A West Lothian EH49 7LR Tel 650 786 3255 Scotland United Kingdom Fax 650 786 3723 Tel 0506 670000 Fax 0506 760011 iv Sun StorEdge network FC switch 8 and switch 16 Installation and Configuration Guide December 2000 Safety Agency Compliance Statements Read this section before beginning any procedure The following text provides safety precautions to follow when installing a Sun Microsystems product Safety Precautions For your protection observe the following safety precautions when setting up your equipment m Follow all cautions and instructions marked on the equipment m Ensure that the voltage and frequency of your power source match the voltage and frequency inscribed on the equipment s electrical rating label m Never push objects of any kind through openings in the equipment Dangerous voltages may be present Conductive foreign objects could produce a short circuit that could cause fire electric shock or damage to your equipment Symbols The following symbols may appear in this book Caution There is risk of personal injury and equipment damage Follow the instructions Surfaces are hot and may cause p
53. work FC switch 8 and switch 16 Installation and Configuration Guide December 2000 Geh useabdeckung Sie m ssen die obere Abdeckung Ihres Sun Systems entfernen um interne Komponenten wie Karten Speicherchips oder Massenspeicher hinzuzuf gen Bringen Sie die obere Geh useabdeckung wieder an bevor Sie Ihr System einschalten obere Abdeckung besteht die Gefahr von Stromschlag und Systemsch den i Achtung Bei Betrieb des Systems ohne Einhaltung der Richtlinien fir Laser Sun Produkte die mit Laser Technologie arbeiten entsprechen den Anforderungen der Laser Klasse 1 Class 1 Laser Product Luokan 1 Laserlaite Klasse 1 Laser Apparat Laser KLasse 1 CD ROM Warnung Die Verwendung von anderen Steuerungen und Einstellungen oder die Durchfhrung von Prozeduren die von den hier beschriebenen abweichen knnen gefhrliche Strahlungen zur Folge haben Conformit aux normes de s curit Ce texte traite des mesures de s curit qu il convient de prendre pour l installation d un produit Sun Microsystems Mesures de s curit Pour votre protection veuillez prendre les pr cautions suivantes pendant l installation du mat riel m Suivre tous les avertissements et toutes les instructions inscrites sur le mat riel m V rifier que la tension et la fr quence de la source d alimentation lectrique correspondent la tension et la fr quence indiqu es sur l tiquette de classification de l app
54. ype of power is supplied to your building Caution Not all power cords have the same current ratings Household extension cords do not have overload protection and are not meant for use with computer systems Do not use household extension cords with your Sun product Caution Your Sun product is shipped with a grounding type three wire power cord To reduce the risk of electric shock always plug the cord into a grounded power outlet The following caution applies only to devices with a Standby power switch A Caution The power switch of this product functions as a standby type device only The power cord serves as the primary disconnect device for the system Be sure to plug the power cord into a grounded power outlet that is nearby the system and is readily accessible Do not connect the power cord when the power supply has been removed from the system chassis Lithium Battery A Caution On Sun CPU boards there is a lithium battery molded into the real time clock SGS No MK48T59Y MK48TXXB XX MK48T18 XXXPCZ M48T59W XXXPCZ or MK48T08 Batteries are not customer replaceable parts They may explode if mishandled Do not dispose of the battery in fire Do not disassemble it or attempt to recharge it Battery Pack A Caution There is a sealed lead acid battery in Sun StorEdge FC AL Switch units Portable Energy Products No TLC02V50 There is danger of explosion if the battery pack is m
55. zschalter A Achtung Der Ein Aus Schalter dieses Ger ts schaltet nur auf Wartezustand Stand By Modus Um die Stromzufuhr zum Ger t vollst ndig zu unterbrechen miissen Sie das Netzkabel von der Steckdose abziehen Schlie en Sie den Stecker des Netzkabels an eine in der Nahe befindliche frei zug ngliche geerdete Netzsteckdose an Schlie en Sie das Netzkabel nicht an wenn das Netzteil aus der Systemeinheit entfernt wurde Lithiumbatterie A Achtung CPU Karten von Sun verf gen ber eine Echtzeituhr mit integrierter Lithiumbatterie Teile Nr MK48T59Y MK48TXXB XX MK48T18 XXXPCZ M48T59W XXXPCZ oder MK48T08 Diese Batterie darf nur von einem qualifizierten Servicetechniker ausgewechselt werden da sie bei falscher Handhabung explodieren kann Werfen Sie die Batterie nicht ins Feuer Versuchen Sie auf keinen Fall die Batterie auszubauen oder wiederaufzuladen Batterien A Achtung Die Ger te Sun StorEdge FC AL Switch enthalten auslaufsichere Bleiakkumulatoren Produkt Nr TLCO2V50 fiir portable Stromversorgung Werden bei der Behandlung oder beim Austausch der Batterie Fehler gemacht besteht Explosionsgefahr Batterie nur gegen Batterien gleichen Typs von Sun Microsystems austauschen Nicht demontieren und nicht versuchen die Batterie aufserhalb des Ger ts zu laden Batterie nicht ins Feuer werfen Ordnungsgem entsprechend den vor Ort geltenden Vorschriften entsorgen viii Sun StorEdge net
Download Pdf Manuals
Related Search
Related Contents
Volet emploi, insertion, développement 4923KB - Dynabook の取扱説明書がダウンロードできます。 consulter en ligne le mode d`emploi - France System 2030 Copyright © All rights reserved.
Failed to retrieve file