Home
Netra CP3060 Rear Transition Module User`s Guide
Contents
1. 8 Tighten the RTM locking screws to ensure that the RTM is secured into the shelf 2 4 Netra CP3060 Rear Transition Module Users Guide December 2006 9 10 Install the node board into the front of the chassis FIGURE 2 1 and push the board toward the midplane Ensure that it is seated properly and that the connectors make good contact with the RTM For further details on installation of the board refer to the Netra CP3060 Board User s Guide 819 4967 Power on the system if necessary Refer to your system manual for instructions on correctly powering on the system 22 Connecting External I O Cables The External I O cables can connect to both the Netra CP3060 board and the Netra CP3060 rear transition module except for the serial cable which connects to either board but not both Information on connecting each of these cables follows m For Ethernet connections category 5e or better network cable is required One end of the Ethernet cable is connected to a suitable 10 100BASE T switch and the other end to the Ethernet port on the Netra CP3060 rear transition module Note The Ethernet ports on the Netra CP3060 board front panel are also usable when the Netra CP3060 rear transition module is installed m Use the bge device names shown in TABLE 2 1 when configuring the Netra CP3060 rear transition module Ethernet port TABLE 2 1 bge Device Names Ethernet Ports Solaris 10 OS RTM Ethernet Port e1000g
2. Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions You can submit your comments by going to http www sun com hwdocs feedback Please include the title and part number of your document with your feedback Netra CP3060 Rear Transition Module User s Guide part number 819 6689 10 xii Netra CP3060 Rear Transition Module Users Guide December 2006 CHAPTER 1 Overview of the Netra CP3060 Rear Transition Module This chapter contains the following sections m Section 1 1 Features of the Rear Transition Module on page 1 2 m Section 1 2 PICMG Standards Compliance on page 1 2 m Section 1 3 I O Interfaces on page 1 3 m Section 1 4 EEPROM on page 1 5 m Section 1 5 Software Support on page 1 5 m Section 1 6 Part Number Serial Number and Revision Number on page 1 6 The Netra CP3060 rear transition module RTM is a fully compatible carrier grade Advanced Telecom Computing Architecture ATCA I O rear transition module for the Netra CP3060 board The Netra CP3060 rear transition module is designed to be used with the Netra CP3060 board and is fully compliant with the PICMG 3 0 and 3 1 specifications However the Netra CP3060 rear transition module is not compatible with other ATCA cards The Netra CP3060 rear transition module requires an ATCA shelf chassis with a midplane that accommodates front and rear board i
3. m wm m m m m w mw w m mw m DG D u u m mu m n nn nu m PCB Chm m m m m m m mu m m mmm mw m m m mw m w mw uw w m m wm mw mw BG Bile mm m m u mjm n m m ff m m m mim m Am wm m m m mm m n Wu M M M M WW am WM M M M NM M W NM ZN ZS TSN VN EEN ZN 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1 FIGURE 3 4 Zone 3 Connectors TABLE 3 3 lists the Zone 3 J10202 connector pinouts TABLE 3 3 Zone 3 J10202 Connector Pin Assignments Row A B BG C D DG E F FG T PCIE Tx7 p PCIE Tx7 n PCIE Rx7 p PCIE Rx7 n n c n c GND 2 PCIE Tx6 p PCIE Tx6 n PCIE Rx6 p PCIE Rx6 n n c n c 3 PCIE Tx5 p PCIE Tx5 n PCIE Rx5 p PCIE Rx5 n GND n c n c 4 PCIE Tx4 p PCIE Tx4 n PCIE Rx4 p PCIE Rx4 n n c n c 5 PCIE Tx3 p PCIE Tx3 n PCIE Rx3 p PCIE Rx3 n n c n c 6 PCIE Tx2 p PCIE Tx2 n PCIE Rx2 p PCIE Rx2 n n c n c GND 7 PCIE Tx1 p PCIE Tx1 n PCIE Rx1 p PCIE Rx1 n n c n c 8 PCIE Tx0 p PCIE Tx0 n PCIE Rx0 p PCIE Rx0 n GND n c n c 9 n c n c n c n c n c n c 10 n c n c n c n c n c n c 3 6 Netra CP3060 Rear Transition Module Users Guide December 2006 TABLE 3 4 lists the Zone 3 J10201 connector pinouts TABLE 3 4 Zone 3 J10201 Connector Pin Assignments Row A B BG c D DG E F FG 1 AMCO_IO1 AMCO_IO2 GND AMCO I03 AMCO_IO4 GND AMCO IO5 AMCO IO6 GND 2 AMCO_IO7 AMCO_IO8 GND AMCO IO9 AMCO IO10 GND AMCO IO11 AMCO IO12 GND 3 AMCOIO24 AMCOIO23 GND AMCOIO2 AMCO 1021 GND AMCOIO2 AMC0 1019 GND 4 AMCOIOI8 AMCO_
4. 4967 Environmental Specifications and Compliance For details on the environmental specifications and compliance see Important Safety Information for Sun Hardware Systems 816 7190 and the Netra CP3060 Board User s Guide 819 4967 You can download and view these documents from the following web site http www sun com documentation 3 2 9 2 1 Hardware Descriptions Ethernet Port The Netra CP3060 rear transition module has one Ethernet RJ 45 connector on its faceplate This port includes the following features m IEEE 802 3 compliant m 10 100BASE TX modes m Autonegotiating 3 2 Netra CP3060 Rear Transition Module User s Guide December 2006 9 22 Asynchronous Serial Port One serial port with a RJ 45 serial connector is included on the Netra CP3060 rear transition module I O faceplate 3 2 0 FRU ID EEPROM A FRU ID EEPROM on the Netra CP3060 rear transition module provides FRU ID functionality as needed The EEPROM contains both IPMI and SUN FRU information 3 9 Connectors and Pin Assignments FIGURE 3 1 shows the location of the connectors Zone 3 connectors Serial port Ethernet port FIGURE 3 1 Netra CP3060 Rear Transition Module Connectors Chapter 3 Hardware Descriptions and Connectors 3 3 3 3 1 3 3 1 1 3 3 1 2 I O Connectors This section lists the pins and signal names of the I O faceplate connectors on the Netra CP3060 rear transition module The faceplate has the
5. access Netra CP3060 rear transition module diskless client configuration The serial port on the Netra CP3060 board s front panel provides the path for the default console I O When the RTM is installed the RTM s serial port also provides a path for the default console I O see FIGURE 1 1 for location Either serial port can be used but only one of the serial ports can be used at a time 1 4 EEPROM The only active component on the Netra CP3060 rear transition module is the PC EEPROM The board is fully passive but some power is provided to the EEPROM The LC EEPROM FRU ID component contains board identification and some manufacturing information such as the part number and date code of the Netra CP3060 rear transition module The IPMC on the Netra CP3060 board monitors and identifies the I C interface The serial EEPROM is accessed through the local Netra CP3060 PC bus 1 5 Software Support The Netra CP3060 rear transition module supports the Netra CP3060 board and the software supported by those boards Refer to the following documentation for software support information m Netra CP3060 Board Product Notes 819 4966 m Netra CP3060 Board User s Guide 819 4967 Chapter 1 Overview of the Netra CP3060 Rear Transition Module 1 5 1 6 Part Number Serial Number and Revision Number The Netra CP3060 rear transition module part number serial number and revision number are labeled on the module Fo
6. following connectors m One 10 100BASE T Ethernet port RJ 45 m One serial port RJ 45 Ethernet Port The Ethernet connector is an RJ 45 connectors The controller autonegotiates to either 10BASE T or 100BASE T FIGURE 3 2 shows an Ethernet RJ 45 connector 12345678 FIGURE 3 2 Ethernet RJ 45 Connector TABLE 3 1 gives the pin assignments for the Ethernet ports TABLE 3 1 Ethernet Port Connector Pin Assignments Pin Signal Name Pin Signal Name 1 TXD 5 Not Used 2 TXD 6 RXD 3 RXD 7 Not Used 4 Not Used 8 Not Used Serial Port The serial port connector is an RJ 45 connector FIGURE 3 3 shows a serial port connector 3 4 Netra CP3060 Rear Transition Module Users Guide December 2006 3 3 2 FIGURE 3 3 Serial Port Connector TABLE 3 2 gives the serial port connector pin assignments 12345678 TABLE 3 2 Serial Port Connector Pin Assignments Pin Signal Name Pin Signal Name 1 RTS 5 DCD 2 DTR 6 RXD 3 TXD 7 DSR 4 GND 8 CTS Zone 3 Connectors All the I O connections for rear access are provided by the Netra node board through the Zone 3 connectors The Zone 3 connectors are J10202 J10201 and J10301 The Zone 3 connectors are shown in FIGURE 3 4 Chapter 3 Hardware Descriptions and Connectors 3 5 J10202 J10201 J10301 HG E LE LJ n LJ t LJ a n n El LJ m LE LJ u LJ id LJ n n LI LJ a n LJ a LJ id a um m m m mmn mim mw m m m m
7. 0 An asynchronous serial I O cable can be attached from serial communication devices to the RJ 45 serial port on the Netra CP3060 rear transition module or on the Netra CP3060 board The serial port on either the Netra CP3060 rear transition module or Netra CP3060 board can be used but both ports cannot be used at the same time Once a serial cable is connected use the tip utility to establish a full duplex terminal connection with the Solaris OS on the Netra CP3060 board At the UNIX prompt in a command tool or shell tool type tip 9600 dev ttya Chapter2 Installation of the Netra CP3060 Rear Transition Module 2 5 2 211 Removing the Rear Transition Module Power to the RTM must be off before the module can be safely removed Therefore the attached node board which provides power to the RTM must be powered off before the module can be removed 1 Power off the attached node board either by turning off the system or by pulling the node board out of the midplane 2 Loosen the locking screws on the RTM 3 Unlatch the top and bottom latches and pull RTM out of the card slot 4 If the card slot is to remain empty install a filler panel in the slot 5 Reinstall the node board if necessary 2 6 Netra CP3060 Rear Transition Module User s Guide December 2006 CHAPTER 3 Hardware Descriptions and Connectors This chapter provides the specifications and connector pinouts for the Netra CP3060 rear t
8. 1017 GND AMCOIOI6 AMCOIOI5 GND AMCO 1014 AMCOIOI3 GND 5 AMCO IO36 AMCO IO35 GND AMCO IO34 AMCO IO33 GND AMCO 1032 AMCO_1031 GND 6 AMCO IO30 AMCO IO29 GND AMCO IO28 AMCO IO27 GND AMCO IO26 AMCO 1025 GND 7 n c n c GND n c n c GND n c n c GND 8 n c n c GND n c n c GND n c n c GND 9 n c n c GND n c n c GND n c n c GND 10 n c n c GND n c n c GND n c n c GND TABLE 3 5 lists the Zone 3 J10301 connector pinouts TABLE3 5 Zone 3 10301 Connector Pin Assignments Row A B BG c D DG E F FG 1 n c n c n c n c n c 12V 2 n c n c 5V n c n c 5V 12V 12V 5V 3 RTM SERI RTM SERI 33V RTM SERI RTM_SERI_ 3 3V RTM_SERI_ RTM_SER1_ 3 3V CTS DTR DCD DSR RXD TXD 4 RTM SERI n c 3 3V n c n c 3 3V n c n c 3 3V RTS 5 n c n c 5V n c n c 5V n c n c 5V 6 RTM_SATAI RTM_SATA1_ GND RTM_ETH_ RTM_ETH_ GND RTM_SATA1_ RTM_SATA1_ GND RX_P RX_N LED_1 LED_2 TX_N TX_P 7 RIM_PRSNT_ 3V_STBY GND RTM_I2C_ RTM_I2C_ GND 3V STBY 3V STBY GND N SDA SCL 8 RTM_SATA2_ RTM_SATA2_ GND RTM ETH RTM ETH GND RTM_SATA2_ RTM_SATA2_ GND RX_P RX_N LED3 LED4 TX_N TX_P 9 RIM ETH RTM_ETH_ GND 2 5V 2 5V GND RTM_ETH_ RTM_ETH_ GND TRD_3P TRD_3N TRD_2P TRD_2N 10 RTM_ETH_ RTM_ETH_ GND 2 5V 2 5V GND RTM_ETH_ RTM_ETH_ GND TRD_1P TRD 1N TRD 0P TRD ON Chapter 3 Hardware Descriptions and Connectors 3 7 3 4 3 8 Jumper Settings There are two jumper positions on the Netra CP3060 rear transition module that are configured in the factory and should not be changed TABLE 3 6 li
9. CA chassis midplane FIGURE 1 2 Relationship of the Netra CP3060 Board ATCA Midplane and Netra CP3060 Rear Transition Module Note When the Netra CP3060 rear transition module is used with a Netra CP3060 board shielded cables are required for serial I O ports Unshielded cables can be used on Ethernet ports to satisfy EMI compliance standards The shields for all shielded cables must be terminated on both ends The customer can order the Netra CP3060 rear transition module build a custom module or buy a module from an independent hardware vendor IHV A minimum set of I O is required to provide a boot path for the Netra CP3060 board and for console I O to issue commands and read board and system status 1 4 Netra CP3060 Rear Transition Module User s Guide December 2006 Possible boot and console configurations are described in TABLE 1 1 Sun Microsystems provides the Netra CP3060 boards and compatible Netra CP3060 rear transition module This module provides one 10 100BASE T Ethernet RJ 45 port from the Netra CP3060 board to the back of the system and can optionally be used for network booting as a diskless client The other configurations require IHV hardware TABLE 1 1 Netra CP3060 Rear Transition Module I O Configurations 1 0 Hardware Required Description Ethernet Netra CP3060 rear transition Default boot path uses an Ethernet port the board runs in a Serial data console module supplied as an option for rear
10. SS 4v SUN microsystems Netra CP3060 Rear Transition Module User s Guide Sun Microsystems Inc www sun com Part No 819 6689 10 December 2006 Revision A Submit comments about this document at http www sun com hwdocs feedback Copyright 2006 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A All rights reserved Sun Microsystems Inc has intellectual property rights relating to Ea is described in this document In particular and without limitation these intellectual property rights may include one or more of the U S patents listed at http www sun com patents and one or more additional patents or pending patent applications in the U S and in other countries This document and the product to which it pertains are distributed under licenses restricting their use copying distribution and decompilation No part of the product or of this document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Parts of the s produet may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo Java AnswerBook2 docs sun com Netra and Solaris are trademarks or registered trad
11. Transition Module Identification Labels 1 6 Installing the Node Board and Rear Transition Module Into the ATCA Shelf 2 2 Injector Ejector Latch and Locking Screw 2 4 Netra CP3060 Rear Transition Module Connectors 3 3 Ethernet RJ 45 Connector 3 4 Serial Port Connector 3 5 Zone 3 Connectors 3 6 vi Netra CP3060 Rear Transition Module User s Guide December 2006 Tables TABLE 1 1 TABLE 2 1 TABLE 3 1 TABLE 3 2 TABLE 3 3 TABLE 3 4 TABLE 3 5 TABLE 3 6 Netra CP3060 Rear Transition Module I O Configurations 1 5 bge Device Names 2 5 Ethernet Port Connector Pin Assignments 3 4 Serial Port Connector Pin Assignments 3 5 Zone 3 J10202 Connector Pin Assignments 3 6 Zone 3 J10201 Connector Pin Assignments 3 7 Zone 3 J10301 Connector Pin Assignments 3 7 Jumper Settings 3 8 vii viii Netra CP3060 Rear Transition Module User s Guide December 2006 Preface The Netra CP3060 Rear Transition Module User s Guide describes the Netra CP3060 rear transition module RTM and provides installation instructions and hardware specifications This manual is written for system integration engineers field applications and service engineers and others involved in the integration of this module into Netra Advanced Telecommunications Computing Architecture ATCA systems How This Document Is Organized Chapter 1 provides an overview of the Netra CP3060 rear transition module Chapter 2 provides instructions on hardwa
12. cript Contents Preface ix Overview of the Netra CP3060 Rear Transition Module 1 1 1 1 Features of the Rear Transition Module 1 2 12 PICMG Standards Compliance 1 2 13 I O Interfaces 1 3 14 EEPROM 1 5 15 Software Support 1 5 1 6 Part Number Serial Number and Revision Number 1 6 Installation of the Netra CP3060 Rear Transition Module 2 1 2 1 Installation and Removal of the Rear Transition Module 2 1 2 1 1 Installing the Rear Transition Module 2 2 2 2 Connecting External I O Cables 2 5 2 2 1 Removing the Rear Transition Module 2 6 Hardware Descriptions and Connectors 3 1 3 1 Specifications for the Rear Transition Module 3 1 3 1 1 Physical Dimensions 3 1 3 12 Power Requirements 3 2 3 1 3 Electrical Requirements 3 2 iv 3 2 3 3 3 4 3 14 Environmental Specifications and Compliance 3 2 Hardware Descriptions 3 2 3 2 1 Ethernet Port 3 2 3 22 Asynchronous Serial Port 3 3 3 2 3 FRU ID EEPROM 3 3 Connectors and Pin Assignments 3 3 3 3 1 I O Connectors 3 4 3 3 1 1 Ethernet Port 3 4 3 3 1 2 Serial Port 3 4 3 3 2 Zone 3 Connectors 3 5 Jumper Settings 3 8 Index Index 1 Netra CP3060 Rear Transition Module Users Guide December 2006 FIGURE 1 1 FIGURE 1 2 FIGURE 1 3 FIGURE 2 1 FIGURE 2 2 FIGURE 3 1 FIGURE 3 2 FIGURE 3 3 FIGURE 3 4 Figures Netra CP3060 Rear Transition Module 1 3 Relationship of the Netra CP3060 Board ATCA Midplane and Netra CP3060 Rear Transition Module 1 4 Rear
13. ear Transition Module User s Guide December 2006 Title Part Number Netra CP3060 Rear Transition Module Getting Started Guide 819 6692 Netra CP3060 Rear Transition Module User s Guide this manual 819 6689 Netra CP3060 Board Getting Started Guide 819 4971 Netra CP3060 Board Product Notes 819 4966 Netra CP3060 Board User s Guide 819 4967 Netra CP3060 Board Programming Guide 819 4969 Netra CP3060 Board Safety and Compliance Guide 819 4965 Important Safety Information for Sun Hardware Systems Printed version only 816 7190 Except for the Getting Started Guides and the Important Safety Information for Sun Hardware Systems all the documents listed are available online at http www sun com documentation Documentation Support and Training Sun Function URL Documentation http www sun com documentation Support http www sun com support Training http www sun com training Third Party Web Sites Sun is not responsible for the availability of third party web sites mentioned in this document Sun does not endorse and is not responsible or liable for any content advertising products or other materials that are available on or through such sites or resources Sun will not be responsible or liable for any actual or alleged damage or loss caused by or in connection with the use of or reliance on any such content goods or services that are available on or through such sites or resources Preface xi
14. emarks of Sun Microsystems Inc in the U S and in other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and in other countries Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc PICMG and the PICMG logo AdvancedTCA and the AdvancedTCA logo are registered trademarks of the PCI Industrial Computers Manufacturers Group The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees Who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements U S Government Rights Commercial use Government users are subject to the Sun Microsystems Inc standard license agreement and applicable provisions of the FAR and its supplements DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2006 Sun Micros
15. er 2006
16. nstallations The primary purpose of this module is to provide rear access connections to the Netra CP3060 board s I O ports The system designer is responsible for integrating peripheral devices with the connectors on the midplane in an ATCA shelf configuration A designer can either connect directly to the midplane signals or use a Netra CP3060 rear transition module This document provides information only for the integration of the Netra CP3060 rear transition module in a supported ATCA shelf 1 1 Features of the Rear Transition Module The 8 rack unit 8U form factor single slot rear transition module supplies rear I O connections that support additional peripherals for use with compatible Netra CP3060 boards The rear I O access enables you to replace the Netra CP3060 boards without disconnecting cables Industry standard connectors and pin assignments ensure ease of use and flexible design The Netra CP3060 rear transition module permits the creation of high density systems by enabling easy access to I O FIGURE 1 1 Features of the Netra CP3060 rear transition module include m One 10 100BASE T Ethernet port with RJ 45 connector on the faceplate m One asynchronous serial port with RJ 45 connector on the faceplate m Field replaceable unit ID FRU ID EEPROM to hold board identification and manufacturing information The EEPROM can be accessed through the Intelligent Platform Management Controller IPMC interface m The Ne
17. o The RTM must be installed before the node board Caution Ensure that no node board is installed in front of the rear midplane slot This precaution is very important if you are installing into a powered midplane Verify that you have taken the necessary antistatic precautions Go to the rear of the system and choose an appropriate slot for the rear transition module The RTM must be installed inline behind the accompanying node board For example if the accompanying node board is going to be installed in slot 3 its RTM must be installed at the back of the system in slot 3 Remove the slot filler panel from the selected node board slot if necessary Prepare the module by loosening the locking screws and opening the injector ejector latches at the top and bottom of the module FIGURE 2 2 Chapter 2 Installation of the Netra CP3060 Rear Transition Module 2 3 Locking screw Injector ejector latch Locking screw Injector ejector latch FIGURE 2 2 Injector Ejector Latch and Locking Screw 5 Carefully align the edges of the module with the guides in the appropriate slot Look into the enclosure to verify correct alignment of the rails in the guides 6 Taking care to keep the module aligned in the guides slide the module in until the injector ejector mechanisms engage 7 Simultaneously push in the module and push the injector ejector mechanisms inward to their closed positions to seat the midplane connectors
18. plane made for front and rear board installations FIGURE 2 1 The module must be installed in the slot directly behind the Netra CP3060 board These back to back slots have common pins to enable passing of signals Before installing the Netra CP3060 rear transition module verify the module s part number to ensure that the correct RTM is being installed into the system For information on identifying the Netra CP3060 rear transition module see Section 1 6 Part Number Serial Number and Revision Number on page 1 6 Caution Rear transition modules built for use with other node boards are not compatible with the Netra CP3060 boards If installed they might cause damage to themselves the node board and the midplane 2 1 Zone 3 connectors Netra CP3060 RTM Netra CP3060 board installed from rear installed from front ATCA chassis midplane FIGURE 2 1 Installing the Node Board and Rear Transition Module Into the ATCA Shelf 2 1 1 Installing the Rear Transition Module The Netra CP3060 rear transition module must be used with a Netra CP3060 board for rear I O access The RTM enables access to the network to a boot device and to a console terminal 2 2 Netra CP3060 Rear Transition Module Users Guide December 2006 Note The Netra CP3060 rear transition module and the corresponding Netra CP3060 board can be installed while the shelf is powered however start with a powered shelf only if you must do s
19. r proper identification of the rear transition module find the Sun Microsystems barcode labels on the module The barcode labels provide the following information m Module part number for example 3753134 which is the first seven digits on the barcode label The next six digits are the module serial number for example 000316 m Product part number including dash level for example 575 3134 03 and revision number for example REV 50 m Module date code for example 17 2006 which represents the seventeenth week of the year 2006 m Country of origin for example Assembled in Taiwan MILLE LE LER VA ELE UI N8050091 IAC RT O HAN RHIN 501 0680000074 FIGURE 1 3 Rear Transition Module Identification Labels 1 6 Netra CP3060 Rear Transition Module User s Guide December 2006 CHAPTER 2 Installation of the Netra CP3060 Rear Transition Module This chapter contains the procedures for installing and removing the Netra CP3060 rear transition module The chapter contains the following sections m Section 2 1 Installation and Removal of the Rear Transition Module on page 2 1 m Section 2 1 1 Installing the Rear Transition Module on page 2 2 m Section 2 2 1 Removing the Rear Transition Module on page 2 6 2 1 Installation and Removal of the Rear Transition Module The Netra CP3060 rear transition module can be installed into an ATCA shelf chassis with a mid
20. ransition module The chapter contains the following sections m Section 3 1 Specifications for the Rear Transition Module on page 3 1 m Section 3 2 Hardware Descriptions on page 3 2 m Section 3 3 Connectors and Pin Assignments on page 3 3 m Section 3 4 Jumper Settings on page 3 8 3 1 CR NIE Specifications for the Rear Transition Module This section provides mechanical electrical environmental and other relevant specifications for the Netra CP3060 rear transition module Physical Dimensions The Netra CP3060 rear transition module is a 322 25 mm x 70 board using an 8U x 6 high profile HP face plate It complies with IEEE 1101 11 mechanical standards as required by the PICMG 3 0 Revision 1 0 specification The Netra CP3060 rear transition module uses alignment pins and blocks for keying to conform with the PICMG 3 0 Keying of ATCA Boards and Backplanes specification 3 1 3 1 2 9 1 9 3 1 4 Power Requirements Most components of the Netra CP3060 rear transition module are passive However some power from the midplane is provided to the DC EEPROM Electrical Requirements The Netra CP3060 rear transition module is powered through the Netra CP3060 board The node board provides the following voltages 3 3V 5V 12V 12V total combined maximum voltage is 2 5 W Some power is provided from the shelf midplane to the I2C EEPROM For more information see the Netra CP3060 User s Guide 819
21. re installation Chapter 3 provides hardware specifications and connector pinouts Using UNIX Commands This document might not contain information about basic UNIX commands and procedures such as shutting down the system booting the system and configuring devices Refer to the following for this information m Software documentation that you received with your system m Solaris Operating System documentation which is at ht tp docs sun com Shell Prompts Shell Prompt C shell machine name C shell superuser machine name Bourne shell and Korn shell Bourne shell and Korn shell superuser Typographic Conventions Typeface Meaning Examples AaBbCc123 The names of commands files Edit your login file and directories on screen Use 1s a to list all files computer output You have mail AaBbCc123 What you type when contrasted su with on screen computer output password AaBbCc123 Book titles new words or terms Read Chapter 6 in the User s Guide words to be emphasized These are called class options Replace command line variables You must be superuser to do this with real names or values To delete a file type rm filename The settings on your browser might differ from these settings Related Documentation For additional information about the Netra CP3060 rear transition module and Netra CP3060 board refer to the following documents x Netra CP3060 R
22. s es de Sun Microsystems Inc aux tats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux tats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc PICMG le Jogo PICMG AdvancedTCA et le logo AdvancedTCA sont des marques de fabrique ou des marques d pos es de PCI Industrial Computers Manufacturers Group L interface utilisateur graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox dans la recherche et le d velo pement du concept des interfaces utilisateur visuelles ou graphiques pour l industrie informatique Sun d tient une license non exclusive de Xerox sur l interface utilisateur graphique Xerox cette licence couvrant Sgalement les licenci s de Sun impl mentant les interfaces utilisateur graphiques OPEN LOOK et se conforment en outre aux licences crites de un LA DOCUMENTATION EST FOURNIE EN L TAT ET TOUTES AUTRES CONDITIONS D CLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA LIMITE DE LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE L APTITUDE A UNE UTILISATION PARTICULIERE OU L ABSENCE DE CONTREFA ON 5 cu CA Adobe PostS
23. sts the factory settings and purpose TABLE 3 6 Jumper Settings Jumper Factory Setting Purpose J0802 Shorted jumper Indicates that the RTM is present installed J0803 Open no jumper Protects the SUN FRU ID data in the upper 2 Kbytes of the EEPROM from being overwritten Netra CP3060 Rear Transition Module User s Guide December 2006 Index A active components 1 5 ATCA shelf 2 1 C cabling 2 5 compliance specifications 3 2 compliance PICMG 1 2 components active 1 5 configurations I O configurations 1 5 connectors Ethernet 3 4 Zone 3 3 5 country of origin labels 1 6 D date code labels 1 6 E EEPROM 3 2 FRU information 3 3 electrical requirements 3 2 environmental specifications 3 2 Ethernet RJ 45 connectors 3 4 F features 1 2 FRU ID 1 2 3 3 FRU information 3 3 I 1 0 configurations 1 5 LC EEPROM 1 5 3 2 installation RTM 2 1 to 2 6 L labels 1 6 P part number labels 1 6 pinouts serial port 3 4 power requirements 3 2 R removal RTM 2 6 RJ 45 Ethernet connectors 3 4 RIM features 1 2 installation 2 1 to 2 6 interfaces 1 3 removal 2 6 S serial EEPROM 1 5 serial interface 3 3 serial port pinouts 3 4 software support 1 5 specifications 1 2 3 1 to 3 2 compliance 3 2 electrical requirements 3 2 environmental 3 2 Index 1 PICMG 1 2 power requirements 3 2 Index 2 Netra CP3060 Rear Transition Module Users Guide Decemb
24. tra CP3060 rear transition module draws power from the Zone 3 connector 5V 3 3V 12V and 12V 1 2 PICMG Standards Compliance The Netra CP3060 rear transition module is fully compliant with the following PCI Industrial Computer Manufacturers Group PICMG specifications m PICMG 3 0 Revision 2 0 m PICMG 3 1 Revision 1 0 1 2 Netra CP3060 Rear Transition Module User s Guide December 2006 Alignment pins keyed to alignment block on node board Locking screw Zone 3 connectors Alignment block keyed to alignment pins on midplane Upper injector ejector latch Serial port RJ 45 Ethernet port RJ 45 Locking screw Lower injector ejector latch FIGURE 1 1 Netra CP3060 Rear Transition Module 1 3 I O Interfaces The Netra CP3060 rear transition module installs into the rear of the ATCA enclosure opposite a Netra CP3060 board The rear transition module connects to the node board s Zone 3 rear I O connectors through the midplane The rear transition module carries one serial port and one Ethernet port with RJ 45 connector to its faceplate FIGURE 1 1 FIGURE 1 2 shows the physical relationship between the node board rear transition module and the midplane in a typical ATCA system Chapter 1 Overview of the Netra CP3060 Rear Transition Module 1 3 Netra CP3060 RTM installed from rear Netra CP3060 board installed from front Zone 3 connectors AT
25. ystems Inc 4150 Network Circle Santa Clara Californie 95054 tats Unis Tous droits r serv s Sun Microsystems Inc poss de les droits de propri t intellectuels relatifs la technologie d crite dans ce document En particulier et sans limitation ces droits de propri t intellectuels peuvent inclure un ou plusieurs des brevets am ricains list s sur le site http www sun com patents un ou les plusieurs brevets suppl mentaires ainsi que les demandes de brevet en attente aux les Etats Unis et dans d autres pays Ce document et le produit auquel il se rapporte sont prot g s par un copyright et distribu s sous licences celles ci en restreignent l utilisation la copie la distribution etla d compilation Aucune partie de ce produit ou document ne peut tre reproduite sous aucune forme par quelque moyen que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y en a Tout logiciel tiers sa technologie relative aux polices de caract res comprise est prot g par un copyright et licenci par des fournisseurs de Sun Des parties de ce produit peuvent d river des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun Java AnswerBook2 docs sun com Netra et Solaris sont des marques de fabrique ou des marques d po
Download Pdf Manuals
Related Search
Related Contents
I 3.8.2.6 TROUBLESHOOTING (CARD READER 型 名 NP-GG。SE2 修理メモ 義 お名前 篇 客 「 一 一 AP DV-5000G Manuale Blue Distinction Centers e-RFI Application Approx APPNB15LB CNC-Spezialmaschine BMW I3 apt Typ FlatCom L Psychologie / Emotions Probador de componentes electronicos M ontage sur rail DIN ESM-1510 Régulateur de température Brodit ProClip 512567 Copyright © All rights reserved.