Home
GL-DEH-45-2 GL-DEH-50-2 GL-DEH-70-2
Contents
1. Esta garant a cubre solamente productos nuevos comprados a distribuidores autorizados o vendedores minorista No cubre mercanc a usada salvada o reconstruida Ya que algunos estados no permiten la limitaci n o exclusi n de da os incidentales o consecuentes o no permiten limi taci n en garant as impl citas las limitaciones y exclusiones antes mencionadas podr an no aplicar a usted Esta garant a le da derechos legales espec ficos y usted podr a tener otros derechos que var an de estado a estado Para Apoyo T cnico y Servicio de Garant a Por favor llamar 888 876 5387 O Escriba Soleus International Inc 20035 E Walnut Dr N City of Industry CA 91789 USA www soleusair com www greeusa com 11 66129909792
2. e The dehumidifier must be operated in an enclosed area to be most effective e Close all doors windows and other outside openings to the room AUTOMATIC DEFROST When frost builds up on the evaporator coils the compressor will cycle off and the fan will continue to run until the frost disappears When the coils is completely defrosted the compressor or fan depending on the model will automatically restart and dehumidification will resume CONTINUOUS DRAINAGE HOSE Water can be automatically emptied by attaching a hose to the continuous drainage port on the side of the dehumidifier This will allow the unit to run continuously depending on the selected humidity level without having to empty the water bucket To drain simply attach a standard garden hose not included Remove the bucket from the front of the unit Open the drain cover on the side of the dehumidifier Thread a garden hose not supplied onto the nozzle cut to length and lead to the floor drain Replace the bucket in the dehumidifier NOTE The bucket must be in place and securely seated for the dehumidifier to operate TROUBLESHOOTING Possible Causes Solutions Dehumidifier does not start The dehumidifier is unplugged Make sure the dehumidifier s plug is pushed completely into the outlet The fuse is blown circuit breaker Check the house fuse circuit breaker box and replace fuse or is tripped reset breaker Dehumidifier has reach
3. SOLEUSAIF Powered by e GREE GL DEH 45 2 GL DEH 50 2 GL DEH 70 2 Portable Dehumidifier Operating Instructions General Dehumidifier Information RECOMMENDED HUMIDITY LEVELS ACCORDING TO ENERGY STAR e Spring Summer 30 50 e Fall Winter 30 40 EMPTYING THE BUCKET The more moisture your dehumidifier removes from the air the more often you may have to empty the bucket unless you are using the continuous drainage option The number of times the bucket will be emptied depends on the dehumidifier model Maximum number of times to empty the bucket when operating at full capacity during a 24 hour period Model Pints of moisture removed per every 24 hour period LESS MOISTURE BEING REMOVED OVER TIME Using a dehumidifier will cause your area to maintain a more comfortable humidity level Over time this humidity level will become more and more stable Due to the stable humidity level in the area the dehumidifier will need to remove less and less moisture over time Please do not be concerned if the dehumidifier is removing less moisture from the air or the bucket is taking longer to fill up This is a direct result of your dehumidifier creating a more stable humidity level in your area FEATURES Removes up to 45 50 70 pints depending on model of mois ture from the air every 24 hours This is not the bucket size Adjustable humidistat for precise humidity control Digital humidistat displays set
4. an cubrir de hielo a temperaturas menores de 41 F que podr a reducir la eficiencia Use el deshumidificador en la cocina lavander a ba o y rea de lavaplatos que tienen humedad excesiva NOTA Coloque el deshumidificador lejos de la secadora de ropa Use el deshumidificador para prevenir danos de humedad en cualquier lugar que libros y objetos valiosos son almacenados Use el deshumidificador en un s tano para prevenir da os por humedad El deshumidificador debe ser operada en una rea encerada para que sea mas efectivo Cierre todas las puertas ventanas y cualquier abertura hacia afuera de el cuarto SI Jrs ON Arriba y i de 4 41 F j it i DESCONGELADOR AUTOMATICO Cuando el hielo se acumula en las bobinas evaporadoras el compresor se apagara y el ventilador continuara funcionando hasta que el hielo desaparezca Cuando las bobinas est n completamente descongeladas el compresor o ventilador dependiendo del modelo autom ticamente reiniciara y el proceso deshumidificador continuara MANGUERA DE DRENAJE CONTINUO El agua puede ser autom ticamente vaciada conectando la manguera a la salida de drenaje continuo en el lado del deshumidificador Esto permitir que la unidad funcione continuamente dependiendo del nivel de humedad seleccionado sin tener que vaciar el conte nedor de agua Para drena continuamente simplemente conecte una manguera de jard n regular no incluida Remueva la tapa del d
5. jelo funcionando durante 24 horas en modo CONTINUOUS Continuo Encendido Apagado Presione el bot n POWER Encendido una vez para encender manualmente la unidad Presione el bot n POWER Encendido otra vez para apagar la unidad Seleccionando la Humedad Presione los botones o para escoger la humedad relativa desea da en el cuarto Cada vez que presione el bot n la humedad relativa cambiara en 5 La humedad del cuarto se puede seleccionar desde 35 80 o CONTINUOUS Continuo La unidad cambiara de ciclo apagado a encendido para mantener el nivel de humedad seleccionada en la pantalla digital Si usted desea que el deshumidificador funcione continuamente sin importar la humedad del cuarto presione el bot n hasta que usted observe CO en la pantalla digital Esto permitir la operaci n continua y el indicador CONTINUOUS se encender en el panel de control NOTA la unidad funcionara por 3 minutos antes de que el compresor se encienda y el proceso deshumidificador inicie Control de Velocidad de Ventilador Presione el bot n FAN SPEED Velocidad de Ventilador para circular entre las diferentes velocidades del ventilador HIGH Alto y LOW Bajo La velocidad del ven tilador puede ser visualmente distinguida por los indicadores de velocidad en el panel de control Temporizador Para programar el apagado autom tico de la unidad presione el bot n TIMER Temporizador cuando la unidad este encendida U
6. en cualquier lugar Perfecta para reas muy transitadas como un cuarto familiar o un dormitorio La protecci n contra la perdida de fluido el ctrico recordara la configuraci n aun cuando el fluido el ctrico sea interrumpido El auto reinicio autom ticamente continua la operaci n cuando el fluido el ctrico sea restablecido no necesita re iniciar el deshumidificador manualmente Gracias por elegir el Deshumidificador Portatil de Soleus Air con potencia Gree Este manual del propietario le proveera valiosa informacion necesaria para el cuidado y mantenimiento apropiado de su nuevo producto Por favor tome unos momentos para leer detenidamente las instrucciones y familiarizarse con todos los aspectos operacionales de su nuevo Deshumidificador Mantenga una copia del recibo de venta con este manual para su informaci n Tambi n escriba a continuaci n el nombre de la tienda direcci n fecha de compra y n mero de serie Nombre de Tienda Direcci n de Tienda Fecha de Compra Numero de Serie ubicado en la parte de atr s de la unidad A INSTRUCCIONES IMPORTANTES Antes de utilizar su deshumidificador por favor lea este manual del propietario cuidadosamente Guarde este ma nual en un lugar seguro para futura referencia 1 Siempre coloque la unidad en una superficie plana 2 Nunca use o almacene gasolina o otros l quidos inflamables cerca de esta unidad a no ser que sea instruido en este manual 3 Mantenga por
7. es La capacidad de su deshumidificador podr a no ser adecuado para muy grande el tama o del cuarto Puertas y ventanas est n abiertas Cierre todas las puertas y ventanas Hay hielo en las bobinas El deshumidificador fue reciente Esto es normal El hielo usualmente se desaparece en 60 minutos mente encendido o la temperatura del cuarto es menos de 41 F Los controles no se pueden con El compresor se apagara y el venti Esto es normal Espere aproximadamente 3 minutos y configure la figurar lador continuara autom ticamente velocidad del ventilador al nivel deseado por 3 minutos a la configuraci n programada Ruido del ventilador El aire se mueve a trav s de la uni Esto es normal dad Agua en el piso La conexi n de la manguera puede Revise la conexi n de la manguera Vea la secci n de Drenaje en estar floja la Pagina 9 Manguera conectada pero no dre Desconecte la manguera si esta usando un contenedor o coloque la nando al drenaje manguera cerca al drenaje AN GARANTIA Un A o de Garant a Limitada Soleus International Inc garantiza que el Deshumidificador de Soleus Air con potencia Gree adjunto esta libre de de fectos en materiales y manufacturaci n para las aplicaciones especificas en sus instrucciones de operaci n por un pe riodo de UN 1 a o de la fecha de compra original en los Estados Unidos S1 la unidad muestra un defecto por uso normal Soleus International Inc podr a optar por ya sea reparar o
8. indicator If the filter 1s torn or unusable order a new filter by calling our customer service CAUTION DO NOT OPERATE THE DEHUMIDIFIER WITHOUT THE INCLUDED FILTER BUTTONS E Uait AI EL IRALA a z m a pal NOTE Do not clean filter in dishwasher CHOOSING A LOCATION A Dehumidifier operating in a basement will have little no effect in drying out an adja cent enclosed storage area such as a closet unless there is adequate circulation of air _ in and out of the area OT I YES NO p e Do not use outdoors PA e This dehumidifier is intended for indoor residential applications only This unit S JA should not be used for commercial or industrial applications e Place the dehumidifier on a smooth level floor surface that is strong enough to support the unit with a full bucket of water Allow at least 12 18 of air flow on all sides and at least 40 for the exhaust side e Place the dehumidifier in an area where the temperature will not fall below 41 F The coils can become covered with frost at temperatures below 41 F which may reduce performance e Use the dehumidifier in cooking laundry bathing and dishwashing areas that have excessive moisture NOTE Place the dehumidifier away from a clothes dryer e Use the dehumidifier to prevent moisture damage anywhere books or valuables are stored e Use the dehumidifier in a basement to help prevent moisture damage
9. reemplazar la unidad libre de cargos dentro de un tiempo razonable despu s de que la unidad ha sido regresada durante el periodo de garant a Como condici n de cualquier obligaci n de servicio de garant a el consumidor debe presentar este Certificado de Ga rant a as como una copia de la factura original de compra ESTA GARANTIA NO CUBRE e Da os accidentales o no a la unidad mientras este en posesi n del consumidor que no fueron causados por defecto en materiales o manufacturaci n e Da os causados por el mal uso del consumidor manipulaci n o por no seguir las indicaciones de cuidado y provisiones de manejo especial en las instrucciones e Da os al acabado exterior de la unidad u otras aspectos de apariencia en el acabado causadas por el uso e Da os causados por reparaciones o alteraciones a la unidad por cualquier otra persona que no este autorizada por Soleus International Inc e Costos de Envi y Seguro para el servicio de garant a TODAS LAS GARANTIAS INCLUYENDO CUALQUIER GARANTIA IMPLICITA EN LA CAPACIDAD DEL COMERCIANTE ESTA LIMITADA A UN A O DE DURACION DE ESTA GARANTIA EXPRESA LIMITADA SOLEUS INTERNATIONAL INC HACE DESCARGO DE CUALQUIER RESPONSABLILIDAD POR DA OS INCIDENTALES O CONSECUENTES Y DE NINGUNA FORMA SOLEUS INTERNATIONAL INC TENDRA RESPONSIBLILIDAD QUE EXCEDA EL VALOR DE VENTA AL DETALLE DE LA UNIDAD POR INCUMPLTI MIENTO DE CUALQUIER GARANTIA YA SEA ESCRITA O IMPLICITA CON RESPECTO A ESTA UNIDAD
10. 50 2 GL DEH 70 2 Capacidad l l r Deshumidificadora 45 Pintas por d a 50 Pintas por d a 70 Pintas por d a Con SAE 600 Vatios 765 Vatios Vatios Volumen de Flujo de Aire Alto Med Bajo 190 170 150 CFM 208 191 156 CFM 208 191 156 CFM Fuente de Energ a 115 V 60 HZ 115 V 60 HZ 115 V 60 HZ 49 dB A 49 dB A 49 dB A Peso de Producto 43 libras 44 1 libras Dimensiones de Producto 5 1075 x 19 25 15 125 x 11 125 x 24 125 15 125 x 11 125 x 24 125 An x P x Al Producto con Energy Star s Si Si PANEL DE CONTROL amp PANTALLA DIGITAL eae indieadoras Luz indicadora de Bucket Full de Retraso de Do Luces indicadoras del indica que el contenedor de agua a j Ahoras para ventilador para Alto debe ser vaciado o no esta Luz indicadora Continuous eee ie see Mediano y Bajo colocado de forma apropiada indica operacion continua f HUMIDITY Luz indicadora de Encendido Luz indicadora E A AA NI E lo a A ee be el eke ee ee eee E ARAS Filtro Ss 02 0 E O p oebDoo p joooocooa lt cesscli LIMIT Jo co ae oe os Pi FIX Jj ooo 008 7eogagaoassefit A ee ee AA ee ee V BOTON AUMENTA DISMINUE BOTON DE TEMPORIZADOR EL NIVEL DE BOTON DE FILTRO BOTON DE H HUMEDADDELA ENCENDIDO VELOCIDAD HABITACION APAGADO DEL VENTILADOR ee INSTRUCCIONES DE USO INSTRUCCIONES DE USO 1 2 Cuando use opere el deshumidificador la primera vez d
11. ASE DECREASE POWER FILTER BUTTON ROOM HUMIDITY BUTTON BUTTON HO OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1 2 When first operating the dehumidifier run it in Continuous mode for 24 hours Power On and Off Press the POWER button once to manually turn the unit on Press the POWER button once more to turn the unit off Humidity Selection Press the or buttons to choose the desired relative humidity in the room Each press of the button will change the desired room humidity by 5 The room humidity is selectable from 35 80 or continuous The unit will cycle on and off to maintain the humidity level chosen on the digital display If you want the dehumidifier to operate continuously regardless of the room humidity press the buttons until you see CO on the digital display This will enable continuous operation and the Continue indicator will light up on the control panel Fan Speed Control Press the FAN SPEED Button to cycle through the different fan speeds High Medium and low The fan speed can be visually distinguished by the fan speed indicators on the control panel Timer To program the unit to automatically turn off press the TIMER button when the unit is on You can select either 2 or 4 hours with the Timer Once the desired time 2 or 4 hours is over the unit will automatically shut down To program the unit to automatically turn on connect the power cord without turning on the
12. S Before installing and using your dehumidifier please read this owner s manual carefully Store this manual in a safe place for future reference 1 2 3 4 5 6 7 8 9 Always place the unit on a level surface Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual Maintain at least 12 18 inches clearance space around this unit at least 40 for the exhaust on the side Do not block or cover air inlet or outlet grilles The unit must be connected to a correctly grounded power supply Do not start or stop the unit by inserting or pulling out the power plug Do not use an adapter plug or extension cord Do not use the unit in the immediate surroundings of a bath a shower or a swimming pool Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills unless instructed by this manual Do not let children play near this unit 10 Always inspect the cord for signs of damage before use If the power cord is damaged it must be replaced by the manufacturer or a qualified service technician 11 When cleaning the unit always turn the unit off and unplug the power cord 4 PACKAGE CONTENTS Portable Dehumidifier Operating Instructions SPECIFICATIONS e Noise level is measured at a distance of 3 28 ft away from the front of the unit e Power consumption is measured when the fan runs at the highest speed set
13. al use Soleus International will at its option either repair or replace it free of charge within a reasonable time after the unit is returned during the warranty period As acondition to any warranty service obligation the consumer must present this Warranty Certificate along with a copy of the original purchase invoice THIS WARRANTY DOES NOT COVER e Damage accidental or otherwise to the unit while in the possession of a consumer not caused by a defect in material or workmanship e Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions e Damage to the finish of the case or other appearance parts caused by wear e Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc e Freight and Insurance cost for the warranty service e Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS INTERNATIONAL INC S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT This warranty covers only new products purchased from our authorized dealers or retailers It does not cover used sal vaged or refurbished products As some
14. ed its The dehumidifier automatically turns off when either condition present level or the bucket is full occurs Change to a lower setting or empty the water bucket and replace properly Bucket is not in the proper The bucket must be in place and securely seated for the dehu position midifier to operate Power Failure There is a protective time delay up to 3 min to prevent trip ping of the compressor overload For this reason the unit may not start normal dehumidification for 3 min after 1t is powered back on Dehumidifier does not dry the air as it should Not enough time allowed for unit When first installed allow at least 24 hours to maintain the to remove moisture desired dryness Airflow is restricted Make sure there are no curtains blinds or furniture blocking the front or back of the dehumidifier See the Choosing a Lo cation section on Page 9 Dirty filter See the Replacing Filter section on Page 8 The Humidity Control may not be For drier air press the button to lower the percent humid set low enough ity desired in the room or set the dehumidifier to CO for maxi mum dehumidification Doors and windows may not be Check that all doors windows and other openings are securely closed tightly closed Clothes dryer may be blowing Install the dehumidifier away from the dryer The dryer should moist air into the room be vented outside Room temperature is too low Moisture removal is bes
15. ero y c modo Con el tiempo el nivel de humedad ser m s y m s estable Debido a la estabilidad del nivel de humedad en el rea con el tiempo el deshumidificador eliminara cada vez menos humedad Por favor no se preocupe si el deshumidificador esta removiendo menos humedad del aire o si el contenedor de agua tarda demasiado para llenarse Este es el resultado directo de su deshumidificador ya que est creando niveles de humedad m s estables en su rea CARACTERISTICAS Elimina hasta 45 50 70 pintas dependiendo del modelo de humedad del aire cada 24 horas Este no es el tamano del contenedor de agua Humidistat ajustable para un control de humedad mas preciso La pantalla digital humidistat configura el nivel de humedad y tambi n el nivel de humedad actual en la habitacion Funciona en bajas temperaturas de hasta 41 F Ideal para usar en sotanos durante el invierno La funci n autom tica de descongelamiento permite derretir el hielo de las bobinas congeladas para un funcionamiento continuo y sin preocupaciones El ventilador de 3 velocidades le permite a usted escoger entre el m ximo poder deshumidificador o un funcionamiento casi silencioso El indicador de contenedor de agua lleno y alarma audible le avisan cuando el contenedor est lleno y listo para ser El temporizador de apagado autom tico apaga autom ticamente la unidad despu s de 2 o 4 horas La operaci n ultra silenciosa le permite usar la unidad casi
16. horas de uso Remueve el filtro de la parte trasera de la unidad presionado los dos boto nes en la parte superior del filtro Lave el filtro con agua tibia enjabonada Secar completamente antes de colocar el filtro Una vez que el filtro esta seco completamente col quelo en la unidad y presione el bot n FILTER Filtro para reiniciar el indicador del filtro S1 el filtro est roto o inservible ordene un filtro nuevo llamando a nuestro departamento de servicio al cliente PRECAUCI N NO OPERE USE EL DESHUMIDIFICADOR SIN EL FILTRO INCLUIDO BOTONES E F Mii ELIT IRALA NOTA No lave el filtro en el lavaplatos ELIGIENDO LA MEJOR UBICACION Un Deshumidificador operando funcionando en un s tano tendr un efecto nulo o muy poco para secar una rea cerrada adyacente de almacenamiento como un closet a no ser que la circulaci n de aire hacia afuera y adentro sea la adecuada No usar al aire libre Este deshumidificador es para uso residencial nicamente Esta unidad no es para uso in dustrial o comercial Coloque el deshumidificador en un superficie nivelada y plana que sea suficientemente fuerte para soportar la unidad con el contenedor de agua lleno Permita por lo menos de 12 18 pulgadas de espacio para la circulaci n de aire en todos los lados y por lo menos 40 pulgadas 40 para el lado de escape Coloque el deshumidificador en una rea donde la temperatura no ser menos de 41 F Las bobinas se podr
17. humidity level and current room humidity level Operates at temperatures down to 41 F Perfect for basement use in the winter Automatic defrost function melts away ice from frozen coils for continuous worry free operation 3 Speed fan allows you to choose between maximum dehumidi fying power or close to silent operation Bucket full indicator and audible alarm signals as soon as the bucket is full and ready to be emptied Automatic shut off timer automatically turns off the unit after 2 or 4 hours Ultra quiet operation allows for use almost anywhere Perfect for heavy traffic areas like a family room or bedroom Loss of power protection remembers all settings even when power is interrupted Auto restart automatically continues operation when power is re stored No need to manually restart the dehumidifier Thank you for choosing a Soleus Air Powered by Gree Portable Dehumidifier This owner s manual will provide you with valuable information necessary for the proper care and maintenance of your new product Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Dehumidifier For your own records please attach a copy of your sales receipt to this manual Also write the store name location date purchased and serial number below Store Name Location Date Purchased Serial Number located on back of unit A IMPORTANT INSTRUCTION
18. ificaci n por 3 minutos des pu s de que el suministro el ctrico sea restablecido El deshumidificador no seca el aire como deber a No suficiente tiempo permitido para Cuando se instale por primera vez permita por lo menos 24 horas que la unidad remueva la humedad para mantener la sequedad deseada Flujo de aire restringido Aseg rese que no hay cortinas persianas o muebles bloqueando el frente o la parte de atr s del deshumidificador Ver la secci n Escogiendo la Ubicaci n en laPagina 9 Filtro sucio Ver la secci n Reemplazando el Filtro en laPagina 8 eo 99 El control de humedad podria no Para aire mas seco presione el bot n para bajar el porcentaje estar lo suficientemente bajo de humedad deseado en el cuarto o configure el deshumidificador a CO para m xima deshumidificaci n Puertas y ventanas podr an no estar Revise que todas las puertas ventanas y otras aberturas est n cerradas ajustadamente cerradas completamente La secadora puede estar emitiendo Instale el deshumidificador lejos de la secadora La secadora debe aire h medo en el cuarto ventilar hacia afuera La temperatura del cuarto es muy La eliminaci n de humedad es mejor en cuartos con temperaturas baja altas Cuartos con temperaturas bajas reducir n la capacidad de eliminaci n de humedad Este modelo esta desenado para operar a temperaturas arriba de 41 F Deshumidificador funciona de masiado El rea para ser deshumidificada
19. lo menos de 12 18 pulgadas de espacio libre alrededor de la unidad por lo menos 40 pulga das para el escape en el lado No bloquee o cubra la entrada o la salida de aire 4 La unidad debe estar conectada correctamente a un suministro de energ a con contacto tierra 5 No encienda o apague la unidad desconectando o conectando el enchufe 6 No use un enchufe adaptador o un cable de extensi n 7 No use esta unidad a los alrededores inmediatos del ba o la ducha o la piscina 8 No inserte nada en la salida de aire No obstruya la entrada o la salida de aire a no ser que sea instruido en este manual 9 No permita que los ni os jueguen cerca de esta unidad 10 Siempre inspeccione el cable de suministro de energ a por da os antes de uso Si el cable de energ a esta da ado debe ser reemplazado por el fabricante o un t cnico de servicio calificado 11 Cuando limpie la unidad siempre apague la unidad y desconecte el cable de suministro de energ a HO CONTENIDOS DE LA CAJA Deshumidificador Port til Instrucciones de Uso ESPECIFICACIONES e Los niveles de ruido son medidos a una distancia de 3 28 pies del frente de la unidad El consumo de energ a es medido cuando el ventilador esta funcionando en la mas alta velocidad Estas especificaciones son para referencia solamente Para informaci n actual por favor lea la etiqueta de informaci n en la parte de atr s de la unidad Numero de Modelo GL DEH 45 2 GL DEH
20. renaje 1 girando la tapa en direcci n contra las del agujas del reloj en la parte de atr s de la unidad Remueva el tap n de drenaje 2 despu s de remover la tapa de drenaje Coloque el conector manguera incluido al deshumidificador Conecte la manguera de jard n no incluida al conector de manguera para iniciar el proceso de drenaje continuo NOTA El contenedor debe estar en su lugar y seguro para que el deshumidificador opere correctamente EXD Lado de la Unidad t SOLUCIONES A PROBLEMAS Problema Posible Razon Soluciones Deshumidificador no empieza El deshumidificador no esta enchu Aseg rese que el enchufe esta insertado completamente en el to fado macorriente El fusible esta fundido el circuito se Revise la caja de fusibles y remplace los fusibles da ados o reini disparo cie el circuito El deshumidificador ha alcanzado El deshumidificador se apaga autom ticamente cuando cualquiera su nivel o el contenedor esta lleno de estas dos situaciones ocurre Cambie a una configuraci n mas baja o vaci el contenedor de agua y col quelo en su lugar apro piadamente El contenedor de agua no esta en la El contenedor debe estar en su lugar y seguro para que el des posici n apropiada humidificador opere correctamente Fallo de suministro el ctrico Hay un retraso de tiempo protector 3 minutos para prevenir una sobrecarga del compresor Por esta raz n la unidad podr a no comenzar normalmente la deshumid
21. states do not allow the limitation or exclusion of incidental or consequential damages or do not allow limitation on implied warranties the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state For Technical Support and Warranty Service Please Call 888 876 5387 Or Write To Soleus International Inc 20035 E Walnut Dr N City of Industry CA 91789 USA www soleusair com www greeusa com 66129909793 Powered by fr GREE GL DEH 45 2 GL DEH 50 2 GL DEH 70 2 Deshumidificador Port til Instrucciones de Uso NS Informaci n General del Deshumidificador NIVELES DE HUMEDAD RECOMENDADOS DE ACUERDO A ENERGY STAR Primavera Verano 30 50 Oto o Invierno 30 40 VACIANDO EL CONTENEDOR DE AGUA Entre m s humedad sea removida del aire mas veces tendr usted que vaciar el contenedor de agua a no ser que usted este usando la opci n de drenaje continuo El n mero de veces que el contenedor de agua sea vaciado depende del modelo del deshumidificador M ximo n mero de veces ue se debe vaciar el Pintas de humedad contenedor cuando esta en Modelo removidas por cada periodo ee i operaci n a capacidad de 24 horas Bae maxima durante un periodo de 24 horas CON EL TIEMPO MENOS HUMEDAD SERA REMOVIDA El uso de un deshumidificador causara que su rea mantenga un nivel de humedad mas placent
22. sted puede seleccionar 2 o 4 horas en el temporizador Una vez que el tiempo deseado 2 o 4 horas ha finalizado la unidad se apagara autom ticamente Para programar que la unidad se encienda autom ticamente conecte el cable de suministro el ctrico sin encender la unidad y presione el bot n TIMER temporizador para seleccionar ya sean 2 o 4 horas Cuando en tiempo deseado 2 o 4 horas ha concluido la unidad se encender autom ticamente Contenedor de Agua Lleno Cuando el contenedor de agua esta lleno la unidad se apagara autom ti camente emitiendo un sonido y la luz de BUCKET FULL INDICATOR Contenedor Lleno se encen der El deshumidificador no funcionara hasta que el contenedor de agua sea vaciado y regresado al la uni dad El contenedor deber a ser limpiada cada pocas semanas para prevenir la acumulaci n de moho hon gos O bacteria Use un detergente suave para limpiar el contenedor Cuando esta limpio y completamente seco regrese el contenedor al deshumidificador NOTA Sostenga el contenedor con ambas manos cuando lo vaci NOTA Cuando el contenedor de agua esta lleno o removido de la unidad el compresor se apagara pero el ventilador continuara funcionando por unos pocos minutos Esto es completamente normal El des humidificador no remover humedad del aire durante este tiempo eee INSTRUCCIONES DE USO 7 el Filtro Cuando sea necesario limpieza el filtro la luz indicadora se encender despu s de 250
23. t at higher room temperatures Lower room temperatures will reduce the moisture removal rate This model is designed to operate at temperatures above 41 F Dehumidifier runs too much The area to be dehumidified is too The capacity of your dehumidifier may not be adequate for the large room size Doors and windows are open Close all doors and windows to the outside Frost appears on the coils The dehumidifier has recently This is normal Frost will usually disappear within 60 minutes been turned on or the room temperature is below 41 F Controls cannot be set The compressor will turn off and This is normal Wait approximately 3 minutes and set the fan the fan will automatically speed at the desired level continue to run for approximately 3 minutes at a fixed setting Air is moving through the unit This is normal Water on the floor Hose connection may be loose Check the hose connection See the Drainage Section onPage 9 Hose is attached but not draining Disconnect the hose if using the bucket or place the hose near a into a drain drain 10 St WARRANTY One Year Limited Warranty Soleus International Inc warrants the accompanying Soleus Air Powered by Gree Dehumidifier to be free of defects in material and workmanship for the applications specified in 1ts operation instruction for a period of ONE 1 year from the date of original retail purchase in the United States If the unit exhibits a defect in norm
24. ting e These specifications are for reference only For actual data please refer to the rating label on the back of the unit MODEL GL DEH 45 2 GL DEH 50 2 GL DEH 70 2 Dehumidifying Capacity 45 Pints per day 50 Pints per day 70 Pints per day Power Consumption 600 Watts 615 Watts 765 Watts Watts Air Flow Volume 190 170 150 CEM 208 191 156 CEM 208 191 156 CEM High Med Low Power Source 115 V 60 HZ 115 V 60 HZ 115 V 60HZ HZ Rated Current Amps Sound Pressure 45 47 49 dB A 45 47 49 dB A 45 47 49 dB A Level dB L M H Weight Weight 35 28 lbs 43 lbs 44 1 441 bs O ier 1 10 25 19 25 15 125 x 11 125 x 24 125 Energy Star Energy Star CONTROL PANEL amp DIGITAL DISPLAY 4 hour or 2 hour Bucket full light indicates delay on off High Mid and Low fan bucket needs to be emptied Continuous operation on indicator lights indicator lights or it is not in the proper place indicator light HUMIDITY ga o a CONTINUOUS E SON Power On O 2HRS O MID AY A G ae e easier indicator light Clean the Filter O LOW indicator light o a o cs o z a o o a a a s o a o ES 3 o gt o a gt e J a o I eooo oa npl anm mma JO nonooaocoa oja oo SAS Sc Cd JJ oe Oe oa eb a se a oi 7 0 000 0 0 AGr bet kee tw momo oto oto ot DDOE E SIMtS 200 8 aesge oo0og0o ooo ooo O 000000000000 2028200000 OMC ODeSODoODooDeDaeaDSe O WMocscadosecnsgcesesaseoasosoaocas TIMER BUTTON FANSPEED INCRE
25. unit and press TIMER button to select either 2 or 4 hours Once the desired time 2 or 4 hours is over the unit will automatically turn on Bucket Full When the water bucket is full of water the unit will automatically shut off make a beeping noise and the Bucket Full Indicator will light up The dehumidifier will not function until the water bucket 1s emptied and placed back inside the unit The bucket should be cleaned every few weeks to pre vent the growth of mold mildew and bacteria Use a mild detergent to clean the bucket Once clean com pletely dry the bucket and place it back inside the dehumidifier NOTE Support bucket with both hands when emptying NOTE When the bucket is full or removed from the machine the compressor will turn off but the fan will continue to run for a few minutes This is completely normal The dehumidifier will not be removing moisture from the air at this time NOTE When removing moisture from the air the dehumidifier will exhaust warm air from the side exhaust vent eee OPERATING INSTRUCTIONS 7 Filter When the filter needs to be cleaned the filter indicator will light up after 250 hours of use Remove the filter from the back of the unit by pressing the two buttons on top of the filter Clean the filter with warm soapy water Dry thoroughly before replacing the filter Once the filter is completely dry place the filter back in the unit and press the FILTER button to reset the filter
Download Pdf Manuals
Related Search
Related Contents
SAMURAI Samsung 720XT Instrukcja obsługi Data Sheet - Mouser Electronics Digitus USB 2.0 Cardreader 24in1 Copyright © All rights reserved.