Home

Quick start guide (English)

image

Contents

1. Electrode error Primary Secondary During pH CAL when appears reading reading secondary reading is with ERR the auto recognized pH buffer standard value E Meter Connections BNC connection for pH ORP Redox or CALIBRATION E pH Calibration pH on Selective Electrodes ISE O Pin connection for half cell reference electrodes i REF Requires separate half cell BNC electrode ATC alr pc pH ote REF is not commonly used and is not required ATC For Automatic Temperature Compensation probe DC Power supply For best results periodic calibration with known accurate standards is recommended The 700 series meters can be calibrated with up to 5 buffers The non volatile memory retains all calibration values upon meter shut down The following calibration standards are autom atically recognized USA buffer group 68 4 01 7 00 10 01 12 45 NIST buffer group 68 4 01 6 86 9 18 12 45 To eliminate temperature errors associated wi th the pH electrode attach the automatic temperature compensation ATC probe for best accuracy 1 Press as needed to select pH 2 Dip the pH and ATC electrodes into pH buffer and press me secondary display will lock on the appropriate buffer value Provide stirring for best results When the READY indicator appears press to accept The primary reading will flash briefly before the se
2. Quick Guide Bench 700 Series INSTRUMENTS OAKION pH mV lon Conductivity TDS Dissolved Oxygen C F AR ERES Part of Thermo Fisher Scientific GETTING STARTED E Keypad Functions Powers the meter on and off Upon power on the meter automatically begins in the mode that was last used Calibration and memory values are retained even if meter is unplugged Toggle between available measurement modes pH Temp mV Temp or ppm mV lon 700 only Also used to switch from pH to Temp during pH calibration mode Press and hold for 5 seconds to enter SETUP mode Toggles between measurement and calibration modes In SETUP mode returns user to the measurement mode MI Memory Insert stores values into memory A Increase value Scroll up in SETUP mode MR Memory Recall recalls values from memory W Decrease value Scroll down in SETUP mode Freezes measured reading Press again to resume live reading Confirms calibration values in CAL mode Confirms selections in SETUP mode View recalled values in memory mode E LCD Annunciators Setup Measurement Calibration Memory mode or mode mode mode when data is stored into memory Measured Measured value is stable value is held i Current During setup measurement select auto hold unit mode ON ready ON or of operation Ready OFF Automatic Error or invalid temperature key pressed compensation is active Prompts user to select buffer
3. Millivolt mV Offset Adjustment Oxidization Reduction Potential ORP or Redox is not a precise measurement but is useful as a relative indicator mV offset adjustment makes readings comparable to a reference 1 Connect an ORP electrode and press Q as needed to select mV or R mV Dip the ORP electrode into a solution with a known mV value and stir Press when the reading is stable The primary display shows the relative millivolt value R mV while the secondary display shows the factory default mV value Adjust the R mV value using or Press or to accept or to cancel The meter allows an adjustable maximum value of 150 mV from the factory default mV value Note When an offset has been stored successfully R mV replaces mV E Ion Calibration lon 700 Only The available ION calibration values are 0 10 1 0 10 0 100 0 and 1000 parts per million ppm Choose a minimum of 2 consecutive values for calibration and prepare the corresponding ion calibration solutions For best results always begin with your lowest standard value followed by the next lowest standard 1 Connect the ISE and press e as needed to select ppm Note The primary reading will show without a stored ion calibration The secondary value is the corresponding mV reading of the ISE 2 Dip the ISE into your lowest standard solution value and stir Press when the secondary eading is stable 3 Press or to match th
4. Wallerstraat 125K eutech thermofisher com info 4oakton com 3862 CN Nijkerk The Netherlands www eutechinst com www 4oakton com eutech thermofisher com www eutechinst com
5. condary display begins scrolling the remaining available buffers 3 Rinse the pH and ATC electrodes then dip into the next pH buffer The secondary display will lock on the appropriate buffer value When the READY indicator appears press to accept The primary reading will flash briefly then display the percent efficiency slope before the secondary display begins scrolling the remaining available buffers 4 To calibrate another buffer repeat step 3 or press eS to return to the measurement mode E Temperature Calibration The thermistor sensor used for automatic temperature compensation and measurement is both accurate and stable Temperature calibration is recommended upon electrode replacement whenever the temperature reading is suspect or if matching against a certified thermometer is desired 1 Connect the temperature probe to the meter and place into a solution with a known accurate temperature such as a constant temperature bath Note To adjust the manual temperature compensation MTC value do not connect the temperature probe Press as needed to select pH or MV R mV Press followed by Q The primary display shows the measured temperature while the secondary display shows the factory default temperature Adjust the temperature using or Press to accept or G to cancel The meter allows an adjustable maximum value of 5 C or 0 9 F from the factory default temperature E
6. e primary display to your corresponding ion calibration value 0 10 1 0 10 etc 4 Press to accept or es to abort The primary display will show the next highest calibration standard value 5 Rinse the ISE then dip into the corresponding calibration standard and stir 6 Press to accept or e to cancel The mV decade slope value will be displayed briefly if the calibration is successful SLP Err indicates calibration for the current point was not successful 7 Revert to step 3 to calibrate additional points or press as needed to return to measurement mode at any time STORING AND RECALLING DATA The 700 series meters can retain up to 100 points into memory for later retrieval 1 In the measurement mode press to insert the measured value into memory The stored memory location value StO is briefly displayed 2 To recall data from memory press location of the most recent stored data is displayed first Press or to select the location of the desired data then press to accept 3 Press to return to the stored data location Press to return to measurement mode For more information on our products please contact our channel partner or visit our websites listed below Eutech Instruments Pte Ltd Oakton Instruments Eutech Instruments Europe B V Blk 55 Ayer Rajah Crescent 625 E Bunker Ct PO Box 254 3860 AG Nijkerk 04 16 24 Singapore 139949 Vernon Hills IL 60061 USA The Netherlands

Download Pdf Manuals

image

Related Search

Related Contents

Applied Comfort Products Inc.  LG WD(M)-14105FD User's Manual  LevelOne CAS-4100  505 Analog I/O Modules  CML47786HX cpuModuleTM User's Manual  SISTEMA BÁSICO DE ÓPTICA J. ROMA, Lda.  France-Chamalières: Machines de fabrication du papier ou du carton  Chevrolet 2013 Traverse Get To Know Manual  Si, pour une raison ou pour une autre, les directives contenues dans  Jeppesen Piracy Update - Jeppesen Commercial Marine  