        Operation& Installation Guide: MP-AMP40-70/100V
         Contents
1.                                                                             1 25in 2 20 in   32 mm   56 mm   Et  L   LA LA  8 12 in   207 mm   2 45 in Bass   vous 2 38 in ID GESTION   62 mm  m S O O      61 mm   MP AMP40 70V                                                                                              Connectors  Controls  amp  Indicators    CONNECTORS     DESCRIPTION  CONTROLS  amp   INDICATORS     2  RCA female     L R      Unbalanced stereo or mono line level audio  input        Maximum Input Level  2 Vrms MONO  1 Vrms  Stereo    MONO Input Impedance  15 kO   3 ft  0 9 m  stereo RCA RCA cable included        Continued on following page     Operations  amp  Installation Guide     DOC  7354A Media Presentation Audio Amplifier  MP AMP40 70 100V e 5    Media Presentation Audio Amplifier Crestron MP AMP40 70 100V       Connectors  Controls  amp  Indicators  Continued     CONNECTORS     DESCRIPTION  CONTROLS  amp   INDICATORS    AUDIO IN AUDIO IN  L MONO  amp  R  balanced     1  5 pin 3 5 mm detachable terminal strip   Balanced unbalanced stereo or mono line level  audio input      Maximum Input Level  2 Vrms mono  or 1 Vrms  stereo   Input Impedance  15 kQ     MP AMPA0 70 only   1  2 pin 5 mm  detachable terminal block    70 V speaker level audio output    Wire Size  Connector accepts 12 AWG  maximum    Output Power  40 watts   70 V    AUDIO OUT  MP AMP40 100 only   1  2 pin 5 mm  100V detachable terminal block   100 V speaker level audio output    Wire Size  Con
2.  and TREBLE controls to their default center detent  positions  and set the VOLUME control to a low  counterclockwise   position    Apply power and verify operation as follows     1  With the 24 Vdc power source connected  the green LED should be  illuminated     2  Slowly turn the VOLUME control clockwise until the audio is at a  comfortable level     3  Adjust the TREBLE and BASS controls to suit personal preference     Operations  amp  Installation Guide     DOC  7354A Media Presentation Audio Amplifier  MP AMP40 70 100V e 7    Media Presentation Audio Amplifier Crestron MP AMP40 70 100V    Problem Solving    Troubleshooting    The following table provides corrective action for possible trouble situations  If  further assistance 1s required  please contact a Crestron customer service  representative     MP AMP40 70 100 Troubleshooting  TROUBLE POSSIBLE CAUSE S  CORRECTIVE ACTION    Power LED does MP AMP40 70 100 is not Verify that the power supply  not illuminate  receiving power  is connected and turned on     Audio is distorted Audio input or speaker Verify that all cables are  or not present at cables are loose or not securely and correctly  speakers  connected  connected at both ends     Audio not present Speaker was momentarily Reconnect speaker and re   at either left or disconnected or shorted  apply power   right channel       NOTE  Any momentary short  misconnection  or overload causes the protective  circuits to turn the unit off  Once the fault 1s cleared  the u
3.  implied   nor authorizes any other party to offer any warranty  including any implied warranties of merchantability or  fitness for a particular purpose  Any implied warranties that may be imposed by law are limited to the terms  of this limited warranty  This warranty statement supersedes all previous warranties     Operations  amp  Installation Guide     DOC  7354A Media Presentation Audio Amplifier  MP AMP40 70 100V e 9      X   CRESTRON     Crestron Electronics  Inc  Operations  amp  Installation Guide     DOC  7354A  15 Volvo Drive Rockleigh  NJ 07647  2033569   Tel  888 CRESTRON 12 12  Fax  201 767 7576 Specifications subject to    www crestron com change without notice     
4. B    10 dB   100 Hz    12 dB   10 kHz   80 Hz to 20 kHz  2 5 dB   75 dB   80 Hz to 20 kHz A weighted  0 5    1 kHz   40 watts at 70 volts  Transformer isolated     40 watts at 100 volts  Transformer isolated     Electronic short circuit and overload  protection      30 mVrms   1 kHz    2 0 amps  Q 24 volts dc  100 240 volts ac  50 60 Hz power pack   included    14 watts   1 8 output power  6 2 watts   Idle  750 mW standby    41   to 122   F  5   to 50   C   10  to 90  RH  non condensing   26 Btu h   1 8 output power    Aluminum with polycarbonate label overlay   vented rear  meets the requirements of UL  2043 for installation in an environmental  air handling  plenum  space    Plastic with polycarbonate label overlay    Freestanding or surface mount  adhesive  feet and mounting brackets included     2 38 in  61 mm  with feet  2 45 in  62 mm   with bracket    8 12 in  207 mm   9 40  239 mm  with  bracket    5 87 in  149 mm   3 4 Ib  1 6 kg        Media Presentation Audio Amplifier  MP AMP40 70 100V e 3    Media Presentation Audio Amplifier Crestron MP AMP40 70 100V    Media Presentation Audio Amplifier Specifications  Continued     SPECIFICATION DETAILS    Available Accessories    CBL RCA2 Crestron Certified RCA Stereo Audio  Interface Cable    RCA to Flying Lead Stereo Audio Cable   Plenum  50 ft   15 m     CBL PWR EXT24V P 6 DC Power Extension Cable  Plenum   6 ft   2 m     MP WP Series Media Presentation Wall Plates    Media Presentation Wall Plates      International Versi
5. CC Rules  These limits are designed to provide reasonable protection against  harmful interference in a residential installation  This equipment generates  uses and can radiate radio  frequency energy and  if not installed and used in accordance with the instructions  may cause harmful  interference to radio communications  However  there is no guarantee that interference will not occur in a  particular installation  If this equipment does cause harmful interference to radio or television reception   which can be determined by turning the equipment off and on  the user 1s encouraged to try to correct the  interference by one or more of the following measures     Reorient or relocate the receiving antenna  Increase the separation between the equipment and receiver  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected    Consult the dealer or an experienced radio TV technician for help    Industry Canada  IC  Compliance Statement  CAN ICES 3 B  NMB 3 B        The specific patents that cover Crestron products are listed at patents crestron com    Crestron and the Crestron logo are either trademarks or registered trademarks of Crestron Electronics  Inc  in the United States and or other  countries  ENERGY STAR is either a trademark or registered trademark of the United States Environmental Protection Agency in the United  States and or other countries  UL and the UL logo are either trademarks or registered trademarks of Underwri
6. Crestron MP AMP40 70 100V    Media Presentation Audio Amplifier    Operations  amp  Installation Guide      X   CRESTRON     This document was prepared and written by the Technical Documentation department at     Important Safety Instructions    e Read these instructions    e Keep these instructions    e Heed all warnings    e Follow all instructions    e Do not use this apparatus near water   e Clean only with dry cloth     e Do not block any ventilation openings  Install in accordance  with the manufacturer s instructions     e Do not install near any heat sources such as radiators  heat  registers  stoves  or other apparatus  including amplifiers  that  produce heat     e Do not defeat the safety purpose of the polarized or grounding   type plug  A polarized plug has two blades with one wider than  the other  A grounding type plug has two blades and a third  grounding prong  The wide blade or the third prong are  provided for your safety  If the provided plug does not fit into  your outlet  consult an electrician for replacement of the  obsolete outlet     e Protect the power cord from being walked on or pinched  particularly at plugs  convenience receptacles  and the point  where they exit from the apparatus     e Only use attachments accessories specified by the  manufacturer     e Useonly with the cart  stand  tripod  bracket or  table specified by the manufacturer or sold with  the apparatus  When a cart is used  use caution  when moving the cart apparatus combination 
7. heads  and power supplies are covered for a period of one  1  year  touch screen display and overlay components  are covered for 90 days  batteries and incandescent lamps are not covered     This warranty extends to products purchased directly from Crestron or an authorized Crestron dealer   Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty  if any     Crestron shall not be liable to honor the terms of this warranty if the product has been used in any  application other than that for which it was intended or if it has been subjected to misuse  accidental  damage  modification or improper installation procedures  Furthermore  this warranty does not cover any  product that has had the serial number altered  defaced or removed     This warranty shall be the sole and exclusive remedy to the original purchaser  In no event shall Crestron  be liable for incidental or consequential damages of any kind  property or economic damages inclusive   arising from the sale or use of this equipment  Crestron is not liable for any claim made by a third party or  made by the purchaser for a third party     Crestron shall  at its option  repair or replace any product found defective  without charge for parts or labor   Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the  unexpired portion of the warranty     Except as expressly set forth in this warranty  Crestron makes no other warranties  expressed or
8. mance   Each model is equipped for shelf or surface mounting to enable  installation virtually anywhere without requiring an equipment rack  Each model  meets the requirements of UL 2043 for installation in an environmental air handling   plenum  space  such as above a suspended ceiling        Features and Functions    Compact single channel power amplifier   ENERGY STAR qualified    40 watts at 70 or 100 volts  mono    Transformer isolated output   High efficiency Class D topology   Energy saving design reduces power consumption when idle  Convection cooled for noiseless operation   simple volume  bass  and treble adjustments   Electronic short circuit and overload protection   Detachable terminal block speaker connection   Balanced line input via detachable terminal block   Unbalanced RCA line input  3 foot   0 9 meter  cable included  Built in stereo to mono summing   Includes surface mounting brackets   UL 2043 compliant for installation within a plenum rated suspended  ceiling       1  The MP AMP40 70V and MP AMP40 100V are ENERGY STAR qualified only when using the  included power pack  Power pack meets ENERGY STAR Version 2 0 Efficiency Level V standards  in compliance with EISA Section 301  US   CECP Tier 2  China   MEPS Tier 2  Australia   and CoC   EU     2  The MP AMP40 70V and MP AMP40 100V are tested by an NRTL  Nationally Recognized Testing  Laboratory  and comply to ANSI UL2043  Fire Test For Products Installed in Air Handling Spaces    Full compliance requires 
9. nector accepts 12 AWG  maximum    Output Power  40 watts   100 V     1  2 1 x 5 5 mm dc power connector  24 volt dc power input  power pack included      1  6 32 screw  chassis ground lug    PWR  1  green LED  indicates operating power  O supplied from external power pack    BASS Rotary low frequency boost cut adjustment   flat at center detent    TREBLE Rotary high frequency boost cut adjustment   flat at center detent    VOLUME Rotary input level adjustment       1  Interface connectors for AUDIO IN  and AUDIO OUT ports are provided with the unit   2  Stereo input is internally summed to mono     6 e Media Presentation Audio Amplifier  MP AMP40 70 100V Operations  amp  Installation Guide     DOC  7354A    Crestron MP AMP40 70 100V Media Presentation Audio Amplifier    Setup    Installation    Mount the MP AMP40 to a flat surface near the audio source equipment  using  included adhesive feet or mounting brackets  screws not supplied      Hardware Hookup    Hardware Connections for the MP AMP40 70 100V  MP AMP40 70 Shown     AUDIO IN  AUDIO IN  AUDIO OUT  PWR 24VDC 2A   Unbalanced Stereo   Balanced Unbalanced 70V Speaker Input Power From    or Mono Line level Stereo or Mono Level Supplied  Audio Input Line level Audio Input Audio Out Power Supply    opoo0o000000p0 D  QOOOOOOOOOGdO E  OpOOOOCOOCOODO  AUDIO IN      2 0A    L R            Ground    Before applying power  do the following   l  Connectall input and output cables  refer to the above illustration      2  Setthe BASS
10. nit should automatically  recover  Should it not  recycling power ensures full recovery     Further Inquiries    To locate specific information or to resolve questions after reviewing this guide   contact Crestron s True Blue Support at 1 888 CRESTRON  1 888 273 7876  or  refer to the listing of Crestron worldwide offices on the Crestron Web site   www crestron com offices  for assistance within a particular geographic region     To post a question about Crestron products  log onto the Online Help section of the  Crestron Web site  www crestron com onlinehelp   First time users must establish a  user account to fully benefit from all available features     Future Updates    As Crestron improves functions  adds new features and extends the capabilities of  the MP AMP40 70 100  additional information may be made available as manual  updates  These updates are solely electronic and serve as intermediary supplements  prior to the release of a complete technical documentation revision     Check the Crestron Web site periodically for manual update availability and its  relevance  Updates are identified as an    Addendum    in the Download column     8 e Media Presentation Audio Amplifier  MP AMP40 70 100V Operations  amp  Installation Guide     DOC  7354A    Crestron MP AMP40 70 100V Media Presentation Audio Amplifier    Return and Warranty Policies    Merchandise Returns   Repair Service    1  No merchandise may be returned for credit  exchange or service without prior authorizati
11. nsulated  dangerous voltage  within the  product s enclosure that may be of sufficient magnitude to  constitute a risk of electric shock to persons        The exclamation point within an equilateral triangle is  intended to alert the user to the presence of important  operating and maintenance  servicing  instructions in the  literature accompanying the appliance        WARNING     THIS IS AN APPARATUS WITH CLASS I POWER  SUPPLY CONSTRUCTION  IT SHALL BE CONNECTED  TO AN ELECTRICAL OUTLET WITH AN EARTHING  GROUND TERMINAL           IMPORTANT     This device can be used with Class 2 output wiring           The marking label is attached on the bottom of the unit     Regulatory Compliance    This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc      i     This product conforms to UL STD 962A  certified to CSA STD C22 2 No  21     ETL CLASSIFIED    LisTEO    Intertek    As of the date of manufacture  the MP AMP40 70V and MP AMP40 100V have been tested and found to  comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance    Labelling     Federal Communications Commission  FCC  Compliance Statement    CAUTION  Changes or modifications not expressly approved by the manufacturer responsible for  compliance could void the user s authority to operate the equipment     NOTE  This equipment has been tested and found to comply with the limits for a Class B digital device   pursuant to part 15 of the F
12. on    1 The MP AMP40 70V and MP AMP40 100V are ENERGY STAR qualified only when using the  included power pack  Power pack meets ENERGY STAR Version 2 0 Efficiency Level V standards  in compliance with EISA Section 301  US   CECP Tier 2  China   MEPS Tier 2  Australia   and CoC   EU     2 The MP AMP40 70V and MP AMP40 100V are tested by an NRTL  Nationally Recognized Testing  Laboratory  and comply to ANSI UL2043  Fire Test For Products Installed in Air Handling Spaces    Full compliance requires plenum rated cables such as Crestron CBL KAUDIO RCAM2 L P 50 audio  cable  CBL SPK P 35 speaker cable  and CBL PWR EXT24V P 6 DC power extension cable  Please  note that the included power pack is not ANSI UL2043 compliant  and thus cannot be installed in an  air handling space unless enclosed in a suitable plenum rated enclosure     CBL KAUDIO RCAM2 L P 50    MPI WP Series       Physical Description    This section provides information on the connections  controls and indicators  available on the MP AMP40 70 100V     MP AMP40 70 Front View    PROFESSIONAL AUDIO AMPLIFIER    TREBLE VOLUME    MP AMP40 70V       MP AMP40 70 Rear View    AUDIO OUT  AUDIO IN 70V       4 e Media Presentation Audio Amplifier  MP AMP40 70 100V Operations  amp  Installation Guide     DOC  7354A    Crestron MP AMP40 70 100V Media Presentation Audio Amplifier       MP AMP40 70 100 Overall Dimensions  MP AMP40 70 Shown                             La PO Bess  mna                                                   
13. on from  Crestron  To obtain warranty service for Crestron products  contact an authorized Crestron dealer   Only authorized Crestron dealers may contact the factory and request an RMA  Return  Merchandise Authorization  number  Enclose a note specifying the nature of the problem  name  and phone number of contact person  RMA number and return address     2  Products may be returned for credit  exchange or service with a Crestron Return Merchandise  Authorization  RMA  number  Authorized returns must be shipped freight prepaid to Crestron  6  Volvo Drive  Rockleigh  N J  or its authorized subsidiaries  with RMA number clearly marked on  the outside of all cartons  Shipments arriving freight collect or without an RMA number shall be  subject to refusal  Crestron reserves the right in its sole and absolute discretion to charge a 15   restocking fee plus shipping costs on any products returned with an RMA     3  Return freight charges following repair of items under warranty shall be paid by Crestron   shipping by standard ground carrier  In the event repairs are found to be non warranty  return  freight costs shall be paid by the purchaser     Crestron Limited Warranty    Crestron Electronics  Inc  warrants its products to be free from manufacturing defects in materials and  workmanship under normal use for a period of three  3  years from the date of purchase from Crestron   with the following exceptions  disk drives and any other moving or rotating mechanical parts  pan tilt 
14. plenum rated cables such as Crestron CBL KAUDIO RCAM2 L P 50 audio  cable  CBL SPK P 35 speaker cable  and CBL PWR EXT24V P 6 DC power extension cable  Please  note that the included power pack is not ANSI UL2043 compliant  and thus cannot be installed in an  air handling space unless enclosed in a suitable plenum rated enclosure     Operations  amp  Installation Guide     DOC  7354A Media Presentation Audio Amplifier  MP AMP40 70 100V e 1    Media Presentation Audio Amplifier Crestron MP AMP40 70 100V    Two models are offered  The MP AMP40 70V has a 70 volt output  and the  MP AMP40 100V has a 100 volt output  High efficiency Class D circuitry delivers  40 watts to drive a distributed speaker system in a meeting room  classroom  or any  other space  The output is transformer isolated to handle long and complex wire runs     Refined  reliable operation is ensured thanks to pop free turn on circuitry and  electronic short circuit and overload protection  An energy saving design achieves  optimum efficiency under load  and the amplifier powers down automatically when  no input signal is detected for more than 5 minutes  reducing overall power  consumption and heat as part of a green system design  The amplifier quickly powers  back on the instant an input signal 1s detected  Its extruded aluminum housing 1s both  attractive and effective at dissipating heat  affording a silent running design without  cooling fans     Installation and setup is simple  A detachable output connec
15. ters Laboratories  Inc  in the  United States and or other countries  Other trademarks  registered trademarks  and trade names may be used in this document to refer to either  the entities claiming the marks and names or their products  Crestron disclaims any proprietary interest in the marks and names of others   02012 Crestron Electronics  Inc     Crestron MP AMP40 70 100V Media Presentation Audio Amplifier    Contents    Media Presentation Audio Amplifier  MP AMP40 70 100V 1  Fntrodustion 4 00 abi atado utu iio l  Featutessand FONCIONS aa I  II M II ME 2  A ee A i M LPS e MU E nee 3   Physical Desctptioliss nee S IE acs t eit atu t istum t M EIE e ae 4   vicio A TE                                                   7  o OT OT Tm 1  Hardware OO ee een 7  PPO ONG ME 19  BAINS ee ee ee 8  A A A taniaec ones onusedt 8  AA A A 8  A A A ee see 8   Return and Warranty POC A ta 9  Merchandise Returns 7 Repair Service augen ita 9  Crestron Limited  WIP iia 9    Operations  amp  Installation Guide     DOC  7354A Contents e i    Crestron MP AMP40 70 100V Media Presentation Audio Amplifier       Media Presentation Audio  Amplifier  MP AMP40 70 100V    Introduction    The Crestron    MP AMP40 series offers a choice of 70 V or 100 V audio amplifiers   each designed to provide a convenient  low cost amplifier solution for a variety of  applications  These amplifiers are ENERGY STAR  qualified to enable  organizations to fulfill their green initiatives without compromising on audio  perfor
16. to  avoid injury from tip over        e Unplug this apparatus during lightning storms or when unused  for long periods of time     e  Referall servicing to qualified service personnel  Servicing is  required when the apparatus has been damaged in any way   such as power supply cord or plug is damaged  liquid has been  spilled or objects have fallen into the apparatus  the apparatus  has been exposed to rain or moisture  does not operate  normally  or has been dropped     e Disconnect power prior to connecting or disconnecting  equipment     e Do not install in direct sunlight     e The apparatus must be installed in a way that the power cord  can be removed either from the wall outlet or from the device  itself in order to disconnect the mains power     e Prevent foreign objects from entering the device          X   CRESTRON     WARNING     TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK   DO NOT EXPOSE THIS APPARATUS TO RAIN OR  MOISTURE  THE APPARATUS SHALL NOT BE  EXPOSED TO DRIPPING OR SPLASHING  OBJECTS  FILLED WITH LIQUIDS  SUCH AS VASES  SHOULD  NOT BE PLACED ON THE APPARATUS           WARNING     TO PREVENT ELECTRIC SHOCK  DO NOT REMOVE  COVER  THERE ARE NO USER SERVICEABLE PARTS  INSIDE  ONLY QUALIFIED SERVICE PERSONNEL  SHOULD PERFORM SERVICE        RISK OF ELECTRIC SHOCK  DO NOT OPEN       AVIS  RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR       The lightning flash with arrowhead symbol  within an  equilateral triangle  is intended to alert the user to the  presence of uni
17. tor facilitates the  termination of speaker wiring up to 12 gauge  Balanced and unbalanced inputs  accommodate either a mono or stereo line level source   allowing for direct  connection to the output of a video projector or display  audio processor  mixer  or  AV switcher  Rotary controls provide for adjusting the overall output volume  as  well as bass and treble     Applications  The following diagram shows an MP AMP40 70 100V in a typical application            POWER  SUPPIY    _ SPEAKERS                   AUDIO  SOURCE  P      ON  WO          Stereo input is internally summed to mono     2 e Media Presentation Audio Amplifier  MP AMP40 70 100V Operations  amp  Installation Guide     DOC  7354A    Operations  amp  Installation Guide     DOC  7354A    Specifications    Specifications for the Media Presentation Audio Amplifier are listed in the following    table     Crestron MP AMP40 70 100V Media Presentation Audio Amplifier    Media Presentation Audio Amplifier Specifications    SPECIFICATION DETAILS    Audio  Input Volume Range  Bass Gain Range   Treble Gain Range   Frequency Response  S N Ratio  THD N    Output Power   MP AMP40 70V     Output Power   MP AMP40 100V     Amplifier Protection    Input Detection Threshold    Power Requirements  Power Pack    Power Consumption    Environmental  Temperature  Humidity  Heat Dissipation   Enclosure  Chassis    Faceplate  Mounting    Dimensions  Height    Width    Depth  Weight     Continued on following page      60 dB to  15 d
    