DEPARTMENT OF TRANSPORTATION STATE
Contents
1. 925 2 36 Loop Detector Wire A Requirements Ensure that loop detector wire meets IMSA specification 51 3 and is 14 AWG Ensure that identification markings are stamped on the cable jacket For special applications loop detection wire that meets IMSA specification 51 7 14 AWG may be used as directed by the Engineer Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 37 Aerial Lashed amp Duct Signal Cable A Requirements Ensure that aerial lashed or duct conduit No 14 AWG stranded 7 conductor with black polyethylene PE jacket and 600 V AC rating meets IMSA specification 20 1 Use conductors that are straight not twisted pairs Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 38 Self Supporting Twisted Pair Aerial Signal Communications Cable A B C D Requirements Ensure that self supporting figure eight aerial signal communications cable No 19 AWG stranded 6 pair conductors is rated at 600 V AC and meet IMSA specification 420 4 1984 Use conductors that are twisted pairs with copper tape shield under a black PE jacket Ensure that messenger strand is 0 25 inch 6 mm 7 strand and conforms to AS
2. Ethernet Controller Controller i Unit nit Slide Out Drawer Input File 1 91 PDA 3 Slide Out Drawer Out Drawer Input File 1 pal ome 3 Output Unit Output Unit 25 omen File Auxiliary File IVDS Coax Termination Panel A FRONT VIEW SECTION A A Door removed for clarity Figure 925 1 Typical 332 Cabinet Configuration 25 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment FDC Clear Space UPS Electronics Module Field Switch Clear Space Clear Space Video Encoder Controller Unit Clear Space Slide Out Drawer Input File gt Battery Shelf 2 J Panel A Battery Shelf 1 Output File Service Entrance Main SS Main Breaker m UPS Distribution Block Auxiliary File FRONT VIEW Doors removed for clarity Figure 925 2 Typical CL4D Cabinet Configuration 26 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment J Panel A Ethernet Surge Rail Field Switch Controller C11 TB Slide Out Drawer Input File Internally Illuminated Street Sign PDA Panel Output Unit Auxiliary File DCG TB1 J Panel B Ethernet Surge Rail Field Switch Controller Unit Slide Out Drawer Input File Auxiliary File Figure 925 2A Typical CL4D J Panels A and B Configuration 27 of 84 Office of T
3. Section 925CL Traffic Signal Equipment B C D Ensure that Closure Cap is injection molded ABS plastic The plastic is to be loaded with UV stabilizers 3 Ensure that Adapter Bar is made so that it will secure the closure cap and compensate for varying thickness of signal heads 4 Provide two 10 9mm screws to fit any manufacturer s signal head Ensure that one screw is 0 75 inches 19 mm in length and the second screw is 1 inch 25 mm in length 5 Pack each assembly in a clear plastic bag Mark the bag with the manufacturer s name and part number Include the Universal Signal Closure Kit in a package containing the span wire clamp and Tri Stud wire entrance fitting 6 Ensure that the Closure Cap is molded to closely match the color of the signal head The adapter bar and screws are to be zinc plated steel Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 46 Cast Aluminum Span Wire Clamp A B C Requirements Provide Span Wire Clamps that are cast from Aluminum Alloy 713 or equivalent free of voids pits dents molding sand and excessive foundry grinding marks Ensure that all design radii are smooth and intact Provide an exterior surface finish that is smooth and cosmetically acceptable free of molding fins cracks and other exterior blemishes Ensure that span wire
4. Traffic Signal Equipment d Event Logging Functions Ensure that the Signal Monitor is capable of storing in non volatile memory a minimum of 100 events Mark each event with the time and date of the event These events consist of fault events AC Line events reset events and configuration change events Provide a graphical means of displaying the signal states of all field inputs for 30 seconds prior to a fault trigger event Provide the capability to assign a four digit identification number to the unit shall be provided Upload the event logs to a PC using the serial port of the Signal Monitor and software provided by the manufacturer Ensure each event log report contains the following information e Monitor ID a four digit 0000 9999 ID number assigned to the monitor e Time and Date time and date of occurrence e Event Number identifies the record number in the log Event 1 is the most recent event 1 Monitor Status Report CS Ensure the Current Status report contains the following information a Fault Type the fault type description b Field Status the current GYR field status and field RMS voltages if the monitor is not in the fault state or the latched field status and field RMS voltages and fault channel status at the time of the fault c Cabinet Temperature the current temperature if the monitor is not in the fault state or the latched temperature at the time of the fault d AC Line Voltage the
5. 28 Provide Detector Test Switch Panel Before providing cabinet submit Detector Switch Test panel design and mounting location for approval Panel shall include one switch for each of the 13 detector inputs a The Detector Test Switch Panel shall be mounted in the cabinet on the rails The panel shall be fabricated from brushed aluminum b Each switch will be labelled as to function The label shall be silkcreened on the test panel and be at least 4 inch in height c A three position switch shall be provided for each detector input The switch shall function as follows e Down Momentary Call is placed into the controller on the appropriate input in parallel with field input e Up Lock Call is placed into the controller on the appropriate input in parallel with field input e Center Lock Normal Operation field output of detector is connected to the controller unit Cabinet Model CLAD Provide Cabinet Model CLAD which is an AASHTO ITE NEMA ITS Cabinet Standard specification Cabinet Housing 3 with two Cages 1 Provide cabinet configured as required herein and as shown in Figures 925 2 925 2A and 925 2B Equipment and materials required under other pay items or other 647 1000 assemblies are shown in the drawings for location purposes and are identified with brackets a Provide four 4 Cage 1 J Panels no less than 55 inches by 20 inches Configure two 2 of the J Panels as for the Cabinet Model 332A arrangement and as show
6. F to 165 F 40 C to 74 C Ensure that the power factor is 90 or greater at nominal rated voltage at 77 F 25 C after 60 minutes of operation Ensure that the total harmonic distortion THD is less than 20 at rated voltage at 77 F 25 C and that all LED traffic signal modules are in compliance with FCC noise regulations Ensure that the LED signal modules operate on line voltage 120 V AC nominal and are able to operate over the voltage range of 80 V AC to 135 V AC Provide transient voltage suppression rated at 1 500 W for 1 millisecond and fusing with a maximum rating of 2 A to minimize the effect and repair cost of an extreme over voltage situation or other failure mode Ensure the modules allow a reduction of the intensity of the light output in response to an input from the traffic signal controller Ensure the minimum light output when dimmed is not less than 3096 of the minimum maintained luminous intensity as defined in the applicable ITE Signal Head Module 4 Operation Supply LED Modules which start counting when the flashing Don t Walk Indication starts and will countdown to 0 when the steady Don t Walk signal turns on Ensure that the unit maintains a consistent countdown during a short power failure i e Traffic Controller does not restart Ensure that if Traffic Controller restarts that the countdown timer display is turned off until one full pedestrian clearance Cycle is timed Ensure that the uni
7. System for use with Light Emitting Diode Traffic Signal Modules at intersections Any reference to Battery Backup System BBS in the Contract Documents is a reference to the UPS system as specified here The UPS shall include but not be limited to the following Electronics module Integrated Power Interface Module and the Battery System The UPS shall be capable of providing power for full run time operation for an LED only intersection all colors red yellow green and pedestrian heads or flashing mode operation The UPS shall also provide power for all auxiliary equipment in the cabinet including but not limited to the cabinet light and ventilation fan auxiliary receptacles except as defined below Internally Illuminated Street Signs Ethernet switches video detection systems and CCTV The UPS shall be designed for outdoor applications in accordance with the CALTRANS TEES The electronics module shall consist of e True sine wave micro processor controlled high frequency inverter e 3 stage temperature compensated battery charger e Local and remote control of UPS functions e Local and remote communications capabilities 1 Operation a b e The UPS shall be capable of on site programming without the use of an external device e g computer PDA etc and be UL listed It shall also conform to all applicable NEMA standards The UPS shall support power connection made to the front or back of the UPS chassis to suppo
8. WDT ERROR Ensure that the unit remains latched in the fault state until reset by the Reset button an External Reset input command or AC Line voltage restoring from an AC Line Brownout event see 2 4 Ensure that a reset resulting from an AC Line Brownout event does not clear the WDT ERROR LED a Controller Watchdog Latch Option Ensure a programming option sets the Watchdog monitoring function to a latching mode and that only a reset from the Reset button or External Reset input can clear a Watchdog fault An AC Line brownout condition will not reset the fault b Controller Watchdog Recognition Time Ensure a programming option sets the maximum Watchdog recognition time to 1000 or 100 ms or 1500 or 100 ms c Controller Watchdog Enable Switch Provide an internal switch to disable the Watchdog monitoring function Mount the switch on the PCB and be clearly label WD ENABLE ON OFF Ensure that placement of the switch in the OFF position causes monitoring of the Watchdog to be inhibited d WDT ERROR LED Control Ensure that the WDT ERROR LED illuminates when the unit has been triggered by a Watchdog fault Ensure that it can only be cleared by a reset command from the front panel Reset switch or External Reset input If the Watchdog monitoring function is inhibited due to the Watchdog Enable switch the WDT ERROR LED shall flash at a 0 5 Hz rate 6 AC Line Monitoring 12 of 84 Office of Traffic Safety amp Design Sectio
9. Beacon Assembly 925 2 15 LED Signal Modules and 925 2 11 Vehicle Signal Heads requirements The Yellow Flashing Beacon shall alternate The flashing beacon cabinet assembly shall be located outside attached to the sign pedestal pole The surge arrestor in the flashing beacon cabinet assembly shall protect the blank out sign and the flasher unit flashing beacons Provide a non fused disconnect switch instead of the circuit breaker required in 925 2 07 wired to disconnect all power to the advance warning flasher assembly e The sign shall be equipped with a photo cell for dimming of the sign legend Dimming shall be as per the manufacturers Specifications e The assembly shall be capable of continuous operation over a temperature range of 37 C 34 F to 74 C 165 F The advance warning flasher blank out sign assembly housing shall consist of The entire front face of the sign shall be protected by a sheet of polycarbonate mounted in the cast door frame Lens material shall be 3 millimeter thick clear polycarbonate with vandal resistant properties e The sign shall include a 2 5 millimeter thick aluminum weatherproof housing and door with internal structural frame e The interior of the unit shall be painted with a flat black enamel to eliminate internal reflection and two coats of yellow standard color No 13538 baking enamel for exterior surfaces e The signal shall completely blank out when not energized Fabrication General Provisions 1
10. C1 connector are compatible with the 2070 controller as applicable according to the required number of input outputs Ensure that the 337 cabinet uses standard Type 170 input and output file units Equip the cabinet with a C2 connector harness with field terminals protected with surge protectors for communication inputs as specified under communications inputs Ensure that the cabinet has two full size doors to allow complete access from the front or back of the cabinet Design the rack assembly to mount in CALTRANS standard rails to allow for a Model 204 flasher Provide a receptacle to accept the plug in power distribution assembly card guides and edge connectors for the input file card guides to support the conflict monitor and load switches and flash transfer relays Due to the compact design of this cabinet assembly the Department of Transportation may accept a non standard type of power distribution assembly PDA Cabinet Model 334 with Auxiliary Output File for Ramp Metering Operations The Controller Cabinet shall comply with the CALTRANS Traffic Signal Equipment Specifications 1989 Model 334 Cabinet Specifications Chapter 6 DO NOT use the February 1993 Amendments for Specifications for the Model 334C Cabinet Do use the Specification Clarifications dated December 20 1993 Provide Cabinet configured as shown in Figure 925 1 23 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 27
11. Cabinet Field Terminal Terminals Required Arrestor Block pecon 925 2 04 A 13 e sector 925 2 04 A 13 f Terminal Block only Section 925 2 04 A 13 f Section 925 2 04 A 13 c peo Table 925 8 Model 334 Default Input File Assignment Detail Slot 1 2 3 4 5 6 7 8 9 Type Det Det Det Det Det Det Det Det C1 Pin Function Field Term C1 Pin Function Field Term 31 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Table 925 9 Required Surge Arrestors for Model 334 Cabinet Field Terminal Terminals Required Arrestor Block TB 2 TB 3 TB 4 Section 925 2 04 A 13 c Section 925 2 04 A 13 c Table 925 10 Model 334 PDA Type 3 Output File sP1 SIE Table 925 11 Model 334 Auxiliary Output File sP9 S P R S P Y S P G S P R S P Y S P G 32 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 925 2 05 Type ITS Cabinet Assemblies A Requirements Ensure that the cabinet assembly meets the requirements of the CALTRANS Specifications as described in this document In addition to the CALTRANS Specifications ensure that the cabinet assembly conforms to the requirements listed below which take precedence over conflicting CALTRANS Specifications 1 Cabin
12. D Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 71 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 925 2 30 Timber Poles A B C D Requirements Ensure that all timber poles meet the requirements of Section 861 Poles must be inspected and tested by the GDOT Office of Materials and Research and hammer stamped by the inspector Ensure that all poles have a brand or stamp 10 feet 3 m from the butt that notes the type wood date of manufacture manufacturer class and length Ensure that all timber poles that have guy attachments or support span wire or arms that suspend signal heads over the roadway or sidewalk are Class II Poles that support loop lead in messenger or communications cable that does not have guy attachments may be Class IV size Ensure that all poles meet the requirements in the table below unless otherwise noted on the traffic signal Plans or list of materials Minimum Circumference Class Nominal Length ft m At 6 feet 2 4 m from butt in mm II 30 9 34 0 850 II 35 10 5 36 5 913 II 40 12 38 5 963 II 45 13 5 40 5 1013 II 50 15 42 0 1050 IV 30 9 29 5 738 IV 35 10 5 31 5 788 IV 40 12 33 5 838 IV 45 13 5 35 0 875 Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Mater
13. Drawer Equip each Model 334 332A CL4D and 3368 cabinet with an aluminum storage compartment mounted in the rack assembly with the approximate following dimensions 16 inches 400 mm wide 14 inches 350 mm long and 1 75 inches 44 mm deep Mount this compartment directly under the Type 2070 controller Provide a drawer with telescoping drawer guides to allow full extension from the rack assembly When extended the storage compartment opens to provide storage space for cabinet documentation and other miscellaneous items Ensure that the storage compartment be of adequate construction to support a weight of 25 pounds 12 kg when extended Provide a top for the storage compartment that has a non slip plastic laminate attached which covers a minimum of 90 of the surface area of the top Auxiliary Equipment Shelf Provide a shelf in each cabinet that provides a location to mount Fiber modem dialup modem and or Field hardened switch Provide shelf in location that allows easy access to AC power outlets and communications links telephone interconnect Locate shelf so as not block access to other equipment or modules including Uninterruptible Power Supply System Do not provide Auxiliary Equipment Shelf in CLAD cabinet Power Strip Equip each 332A and 3368 cabinet with a metal power strip minimum of 4 outlets to support AC power for external communications devices in cabinet Ensure that the power strip may be used by block power supp
14. Ensure that total power required for any single indication does not exceed 250 W Ensure that all modules are contained behind a water tight signal face or lens assembly oen c Ensure that the entire optical system is weatherproof and is not vulnerable to extremes in temperature or moisture B Fabrication General Provisions 101 through 150 C Acceptance General Provisions 101 through 150 D Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 19 Pedestrian Push Button Station A Requirements Ensure that Pedestrian push buttons are of tamperproof construction and consist of a direct push type button and single momentary contact switch in cast aluminum housing The pushbutton cover shall also be of cast aluminum The housing and cover shall be free of voids pits dents molding sand excessive foundry grinding marks Exterior surface shall be smooth and cosmetically acceptable free of molding fins cracks and other exterior blemishes Provide housing and cover with an alodine conversion coating so as to provide a proper base for paint adhesion Finish the housing with baked enamel and paint the push button housing and pedestrian heads flat black unless otherwise specified by the Engineer The assembly shall be capable of being mounted to a flat or curved surface Ensure the assembly includes the appropriate sign as shown in the Plan Details Ensure that any screws or bolts are stainless steel and vanda
15. Monitor automatically logs the new setting Ensure that these settings include the permissive diode matrix all switches all jumpers and the Watchdog Enable switch Provide a programming option such that any change in the configuration parameters will cause the Signal Monitor to enter the fault mode causing the Output relay contacts to close and enabling the Stop Time output to the controller To indicate this fault mode ensure that the PCA indicator will flash at a 4 Hz rate Depressing the Reset button for 5 full seconds is required to clear this fault and log the new configuration parameters If the programming option is not selected ensure that the unit does not set the fault mode but will still log the configuration change 13 Program Card Ajar Ensure that when the Programming Card is removed or not seated properly the Signal Monitor forces the Output Relay to the de energized fault state enable the Stop Time output and illuminate the PCA LED A reset command from the front panel Reset switch or External Reset input is required once the Program Card is in place Exit Flash When the Signal Monitor exits the flash state Output relay de energized as a result of a Reset command or AC Line brownout restore ensure that the Stop Time output goes to the inactive state 250 OR 50 ms before the Output relay transfers to the energized state This transition will provide an early indication to the Controller Unit that the cabin
16. Ph8Det Ph8Det Ph8Det SpDet4 SpDet8 Pd8Det Pre4 Spare 2 Field Term TB 3 3 4 TB 3 7 8 TB 3 11 12 TB 5 3 4 TB 5 7 8 TB 5 11 12 TB 7 3 4 TB 7 7 8 TB 7 11 12 TB 8 8 9 TB 9 7 9 TB 8 2 3 SIU Pin A26 B26 A27 SIU Byte Bit 9 0 9 1 9 2 SIU Input Opto In 2 Opto In 3 Opto In 4 2070 Input NA NA NA 2070 Port Function 40 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Table 925 14 Required Surge Arrestors for Model 342 ITS Cabinet Field Terminal Block Required Arrestors for Model 342 Cabinet TB 8 1 12 Section 925 2 05 A 10 f TB 9 10 12 Section 925 2 05 A 10 f TB 9 4 9 Section 925 2 05 A 10 f TB 2 TB 3 TB 4 TB 5 TB 6 TB 7 1 12 Section 925 2 05 A 10 c Table 925 15 Model 342 amp 346 ITS Cabinet Default Output File Assignment Detail 4 5 6 7 8 9 SIU Pin A17 B18 SIU Byte Bit 5 3 5 6 6 1 6 4 6 7 SIU Output 28 31 34 37 40 2070 Output 21 18 16 53 50 2070 Output Port i A 3 6 3 3 3 1 7 6 7 3 AMU Pin C25 C26 C27 C28 C29 AMU Channel 10 11 12 13 14 Field Term TR 10 1 2 TR 11 1 2 TR 12 1 2 TR 13 1 2 TR 14 1 2 Function Ph7Rd Ph8Rd Pd8DW OvARd OvB Rd SIU Pin A4 B5 A7 B8 B17 A22 SIU Byte Bit 24 2 7 3 2 5 7 7 0 SIU Outpu
17. Signal Equipment adequate cable length to allow attachment in an existing NEMA Cabinet Ensure that the terminal blocks allow for two connections B Fabrication General Provisions 101 through 150 C Acceptance See Subsection 925 2 01 for compliance with CALTRANS QPL D Materials Warranty See Subsection 925 2 01 D for Materials Warranties 925 2 04 Cabinet Assemblies A Requirements Ensure that the cabinet assembly meets the requirements of the CALTRANS Specifications as described in this document In addition to the CALTRANS Specifications ensure that the cabinet assembly conforms to the requirements listed below which take precedence over conflicting CALTRANS Specifications 1 Cabinet configuration Supply cabinets in accordance with these Specifications Equip the cabinets with auxiliary equipment as follows a Model 332A Cabinet Lower input field termination panel 3 Model 242 DC Isolators in Slots 12 13 and 14 of Upper Input File 4 Flash Transfer Relays 2 Model 204 Flashers 1 Auxiliary Cabinet Shelf to support Communication Devices 1 4 Position Power Strip 1 Manual push button assembly I Auxiliary Output File Model 336S Cabinet 3 Model 242 DC Isolators in Slots 12 13 and 14 of Input File 4 Flash Transfer Relays 2 Model 204 Flashers 1 Auxiliary Cabinet Shelf to support Communication Devices 1 4 Position Power Strip 1 Manual push button assembly 1 M Base Adapter
18. Testing of Yellow Circular Modules shall not be required to meet the 165 F requirement Initial intensity measurements shall meet or exceed 12046 of the values shown in Table 925 19 No optical lens shall be used in order to meet these visibility requirements Ensure the report includes a Minimum Maintained Luminous Intensity chart for the module being provided that uses the same horizontal and vertical angles as shown in Table 925 19 Ensure all modules are provided with a signed copy of the production and test and inspection as detailed in section 6 3 of the ITE Vehicle Traffic Control Signal Heads LED Circular Signal Supplement Supply lenses for that are made of ultraviolet stabilized polycarbonate Ensure that the external lens surface is smooth with no raised features to minimize the collection of dirt diesel smoke and other particulate contaminates and to facilitate periodic cleaning Ensure that Circular Signal Modules have prominent and permanent markings to designate the proper orientation of the signal module in the traffic signal housing This marking should be an up arrow or the word UP or TOP Ensure Circular Signal Module meets the photometric requirements as indicated and described in the ITE VTCSH LED Circular Signal Supplement Ensure Circular modules do not use optical lens and provide a uniform appearance incandescent look Supply Red and Yellow LEDs that utilize AllnGap technology either AS Absorbing Substra
19. an assembly that allows for 360 degrees of rotation with no internal bracing obstructing the center opening Provide two air craft grade galvanized steel cables that have minimum tensile strength of 100 000 PSI Ensure that each bracket is complete with all necessary bolt washers gaskets and miscellaneous items to allow assembly of the signal to the bracket and the bracket to the mast arm Ensure all aluminum parts have an Aldine finish All non stainless steel parts shall have a flat black zinc di chromate or galvanize finish This item will be approved upon submittal of catalog cuts Refer to Standard Detail Drawings for additional information Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01D for Materials Warranties 925 2 24 Hardware For Signal Head Pole Mounting A B C Requirements Ensure that this item consists of hardware adequate for the specific mounting As a minimum provide the following hardware 1 inch pipe nipples of die cast aluminum that are a minimum of 12 inches and threaded with 1 inch NPS threads on either end On the upper and lower arm there shall be a serrated 72 tooth boss with set screw The upper arm shall have a neoprene gasket to provide weather tight fit Hub plates for pole mounting shall be provided and they shall be appropriate for the particular mounting round or flat Hardware shall die cast alum
20. and Thread pitch 10 32 e Material 18 8 stainless steel Type 316 stainless steel is acceptable as an alternate e Washer Use one flat washer 18 8 stainless steel under the head of each 10 32 screw provided that the screws are properly tightened lock washers are unnecessary e Number of screws per hinge bracket Minimum of six 6 screws per hinge bracket spaced evenly along bracket with one screw near each end a The UPS shall be mounted internally in the traffic control cabinet including batteries b Provide a shelf to rest the UPS electronics module unit Ensure the shelf supports the weight of the UPS unit and is similar to the contronller shelf required in the 170E cabinet assembly Mount the shelf such that the UPS unit is at the very top of the cabinet rack utilizing the first rack unit position C Provide a baterry shelf or shelves for supporting the batteries Ensure the shelf is adequate to support the weight of the batteries 8 All wiring and cabling associated with the UPS shall be strain relieved routed and secured for protection Provide protective bushings where any cables pass through panels or shelves 45 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 3 Maintenance Displays Controls and Diagnostics a The UPS shall include a display and or meter to indicate current battery charge status and conditions 1 The UPS shall provide voltmeter standard probe
21. be mounted on a standard 35 mm DIN rail c The maximum width of the device is 13 mm 0 512 inch d The circuit breaker can be reset after tripping e The device shall accept 14 AWG wire Environmental The circuit breaker shall operate as specified within the temperature range of 34 to 165 F 34 to 92 degree C b Over Voltage Surge Protector 1 2 Electrical a The nominal voltage rating shall be 120VAC b The device shall be rated for 20 A c The device shall be rated to sink a minimum discharge surge current for 10 kA when tested with the IEEE C62 41 8 20 micro second wave form d The over voltage protection level shall meet UL 1449 6 kV 500A L N 500 V e The surge protector shall include integral monitoring of protection status with an LED indicator for faults Mechanical 83 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment a The device shall mount on standard 35 mm DIN rail b The maximum width of the device is 18 mm 0 7 inch c The device shall accept 14 AWG wire 3 Environmental Operating Temperature 13F to 185 F 25 to 85 degree C c Terminal Blocks 1 Electrical a The maximum nominal voltage rating is 600 V b The surge voltage rating is 8 kV c The terminal block is rated for a maximum load capacity of 20 A 2 Mechanical a Mount on standard 35 mm DIN rail b The maximum width of the device is 10 2 mm 0 402 inche
22. button assembly is configured to have an embossed arrow on the convex surface of the button The arrow shall be capable of rotating for proper movement direction Ensure the rotation of the button will not affect the successful operation of the pedestrian detection Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01D for Materials Warranties 925 2 20 Signal Head Back Plate A B C Requirements Ensure that each back plate is designed to properly shield a traffic signal head from background distractions for better visibility Design the back plates to extend beyond the signal head to a minimum of 5 inches 125 mm on all sides and have all corners rounded with minimum 2 inch 50 mm radii Construct the back plates from aluminum material with a finished color of flat black Ensure that each back plate has two coats of baked on enamel paint Ensure that back plates are at least 0 05 inches 1 mm thick Design the back plates with predrilled holes to provide for simple attachment to the specified brand size and configuration of traffic signal head with all mounting hardware included Ensure that the back plates do not interfere with the signal mounting hardware Ensure that the back plates include louvers Ensure back plates project a rectangular appearance at night by having a 1 inch 25 mm yellow retroreflective strip alon
23. clamps are fabricated from aluminum ingot with minimum requirements as follows e ALUMINUM ALLOY No 713 e YIELD STRENGTH ksi MPa 25 172 e TENSILE STRENGTH ksi MPa 35 240 e BRINELL HARDNESS 75 e ELONGATING 46 in 2 inches SO mm 3 Ensure that the Span Wire Clamp can accommodate cables 0 25 inch 6 mm to 0 63 inch 16 mm diameter Ensure that the weight is less than 1 75 pounds 0 8 kg with hardware Ensure that the Span Wire Clamp have a minimum overall length of 7 inches 175 mm DR Ensure that the Span Wire Clamp have a centerline dimension from cable to clevis pin of 2 inches 50 mm 0 5 inches 13 mm sa Ensure that the Span Wire Clamp have a cast aluminum cable bar to protect the cable when tightening the U bolts a Ensure that the Span Wire Clamp have a mounting opening of 0 75 inches 19 mm 0 03 inches 0 8 mm 7 Ensure that the Span Wire Clamp have 0 5 inch 13 mm 13 NPT U bolts with 0 5 inch 13 mm lock washers and nuts 8 Ensure that the clevis pin are 0 63 inch 16 mm diameter with a length of 2 25 inches 56 mm and secured with a hump back stainless steel cotter pin 9 Ensure that the Clamp and Cable Bar have an Alodine 1200 conversion coating to help resists oxidation 10 Ensure that the Clevis Pin and hardware are galvanized per ASTM 123 A 123M or stainless steel Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 7
24. devices assembly PCB external serial port connectors CPU active LED indicator and Front Panel Harness Ensure it contains any configuration jumpers to be compatible with current GDOT Applications software Ensure the 2070 3B Front Panel Assembly Module functions with Model 2070LB Controller Assembly and is compatible with current GDOT applications software Ensure the hardware hinge attaching devices mate with existing 2070 assemblies Ensure the Front Panel Harness is connected to the front panel via a removable connector Ensure the front panel connector supports the aux switch 2070 4B Power Supply Module The 2070 4B Power Supply Module may be supplied as a separate item and is an independent self contained module Ensure that it is vented and cooled by convection only Provide module that slides into power supply compartment from the back of the chassis and is attached to the Backplane mounting surface by its four TSD 3 Devices Ensure the module supplies at least 3 5 amperes of 5VDC Ensure the 2070 4B Power Supply Module is compatible with Models 2070L 2070LB and 2070LC Controller Assemblies and is compatible with current GDOT applications software Ensure the connection harness PS 2 on existing units can be mated with the 4B module supplied A 2070 4A Power Supply Module may be provided in place of a 4B module as long as it is labeled as such and there is no additional cost to GDOT or Clayton County Ensure the module supplied is appropriat
25. easily adjustable to fit all sizes of round elliptical or other shaped structure without special tools or equipment 68 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment B C D 3 Signal Sign Accomodations Ensure the bracket attaches to the signal Or sign to assure maximum rigidity When clamping the signal top and bottom ensure a standard bracket accommodates all major signal manufacturers signal for 3 4 and 5 section signal head configurations 4 Wiring All electrical wiring shall be completely concealed with the bracket The vertical support shall be a gusseted C shaped extruded aluminum tube to accommodate the signal cable regardless of vertical positioning of the tube 5 Materials The upper and lower arms shall be cast 319 aluminum or equivalent The lower arm shall be internally threaded to accommodate the threaded vertical support tube Ensure the lower arm is furnished with plastic covers which slide and snap into place Both arms shall have 72 tooth serrations cast into the arm to assure a positive lock with signal housing and shall be secured about their rotational axis with setscrews Ensure the arms have a tri bolt arrangement for attachment to the signal housing Ensure the vertical support is gusseted tube extruded from 6063 T6 aluminum Ensure the tube includes a vinyl closure strip Ensure the mast arm clamp assembly is cast from 713 aluminum alloy or equivalent Provide
26. for each low voltage DC input channel which meets the same requirements as the communication inputs with the following exception of the Voltage clamp which shall be 30 V line to line Provide surge arrestors in the cabinet as shown in Table 925 5 Table 925 7 or Table 925 9 for the applicable cabinet 11 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 14 Type 2010 Signal Monitors a Introduction This Specification sets forth the minimum requirements for a rack mountable sixteen channel solid state 2010 Signal Monitor for a Type 170E Traffic Cabinet Assembly Ensure that as a minimum the Signal Monitor complies with all Specifications outlined in Chapter 3 Section 6 of the California TEES August 2002 Where differences occur this Specification governs Ensure that the manufacturer of the unit is listed on the current California Department of Transportation CALTRANS Qualified Products List QPL for signal monitors Provide a Signal Monitor that is capable of monitoring sixteen channels consisting of a Green input a Yellow input and a Red input for each channel Ensure that the unit also includes the enhanced monitoring functions described in Subsection 925 2 04 A 15 b diagnostic display functions described in Subsection 925 2 04 A 15 c event logging functions described in Subsection 925 2 04 A 15 d communications functions described in Subsection 925 2 04 A 15 e and hardware functions d
27. had a major design change the State will make the final determination if Design Qualification Testing is required prior to production consideration Production Quality Control tests shall be performed on each new system prior to shipment Failure to meet this requirement shall be cause for rejection The manufacturer shall retain test results for seven years Each UPS shall be given a minimum 100 hour burn in period to eliminate any premature failures Each system shall be visually inspected for any exterior physical damage or assembly anomalies Any defects shall be cause for rejection Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties Manufacturers shall provide a two 2 year factory repair warranty for parts and labor on the UPS from date of acceptance by the Department Batteries shall be warranted for full replacement for two 2 years from date of purchase The warranty shall be included in the total bid price of the UPS 925 2 07 Flashing Beacon Assembly A Requirements This specification is for a flashing signal cabinet which consists of an aluminum cabinet containing a flasher assembly Field connection terminal block surge arrestor and circuit breaker wired in a manner to operate flashing beacons Refer to Figure 925 7 47 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment NEMA Fisher oo209 TB o 000 Arrestor Note Front view of cabinet Do
28. have a minimum of two terminals b The terminal block shall have two mounting screws c The terminal block shall have a metallic wire protector to physically isolate the conductors from the terminal screws d The terminal block shall be for size 18 to 10 AWG e The terminal block shall be UL rated for 600V 10 amps Mounting a The size of the mounting strut shall be 3 X 1 5 X 1 4 7 62 cm X 3 81 cm X 0 635 cm b The mounting strut shall be made of aluminum c The mounting strap shall be 1 2 inch stainless steel d Paint mounting strut to match junction box e Drill and tap as indicated in detail f Mount junction box to mounting strut with 4 x 20 1 inch bolts flat washer and 4 inch standoff spacer 3 Lighted Street Name Sign Termination Panel Sub Assembly The termination panel shall be made of nominal thickness 0 125 3 28 mm aluminum The panel shall be drilled and bent as indicated in the detail Mount a circuit breaker two surge protectors and terminal blocks on the panel The terminal panel shall be fastened to DIN Rail and then mounted in the cabinet as shown in the detail a Circuit Breaker Thermal Magnetic Circuit Breaker TMCP 1 2 3 Electrical a The nominal rated trip current shall be 5 A b The nominal voltage rating shall be 120 VAC Mechanical a The device shall mount on standard 35 mm DIN rail b The circuit breaker or the circuit breaker s terminal block must
29. input jacks and to read the exact battery voltage drop at the inverter input 2 The UPS shall include a 0 to 100 battery capacity LED indicator The UPS shall have built in TVSS surge suppression compliant with IEEE ANSI C 62 41 The UPS shall be equipped with an integral system to prevent battery from destructive discharge and overcharge The UPS and batteries shall be easily replaced with all needed hardware and shall not require any special tools for installation The UPS shall include a front panel event counter display to indicate the number of times the UPS was activated and a front panel hour meter to display the total number of hours the unit has operated on battery power Both meters shall have push button resets Manufacturer shall include a set of equipment lists operation and maintenance manuals and board level schematic and wiring diagrams of the UPS and the battery data sheets Manual shall conform to TEES August 16 2002 Chapter 1 Section 1 2 4 2 UPS shall provide front panel controls for Power ON Cold Start Alarm Silenece Battery Test Bypass Breaker DC Battery Breaker Battery Test Points Auxiliary Temperature Connector and Programmable Keys UPS shall provide a standard RS232 interface using a DB 9 Connector for remote monitoring and control of the UPS functions Remote monitoring software for the RS232 interface and the serial cable for connection to a laptop computer shall be provided Serial Inter
30. is a precision screw machine type socket with a gold contact finish providing a reliable gas tight seal Low insertion force sockets or sockets with wiper type contacts are not acceptable Internal Power Supply Use a built in high efficiency switching power supply to generate all required internal voltages Ensure that all supply voltages regulated Failure of the internal power supply to provide proper operating voltages shall force the output Relay to the de energized fault state enable the Stop Time output and illuminate the DIAGNOSTIC indicator Provide a user replaceable slow blow fuse for the AC Line input Ensure the unit is operational over the AC Line voltage range of 75 Vac to 135 Vac EIA 232 Interface Ensure the EIA 232 port interface electronics is electrically isolated from all monitor electronics except chassis ground Configuration Parameters Select user programmed configuration settings using PCB mounted switches or jumpers Designs requiring a Personal Computer PC to program or verify the configuration parameters are not acceptable Ensure that user programmed configuration settings that are transferred to memory are stored in a programmable read only memory PROM or EEPROM Designs using a battery to maintain configuration data are not acceptable Field Terminal Inputs Ensure that all 120 Vac field terminal inputs provide an input impedance of 150K 50K ohms and be terminated with a discrete resistor having a po
31. than 100V in less than 1 1 us at 10 kV us 0 01 microsecond or less difference at 10 kV us impulse Withstands 20A AC for one 1 second applied ten 10 times at three 3 minute intervals on either section Current rating Capacitance Inductive Loop Detector Inputs 10 000A 8 x 20 us impulse 6 pF line to ground Provide surge arrestors in the cabinet as shown in Table 925 5 Table 925 7 or Table 925 9 for the applicable cabinet Protect each inductive loop detector channel input by an external surge protection device that meets or exceeds the following requirements e Athree terminal device two 2 of which are connected across the signal inputs of the detector with the third connected to the chassis ground to protect against common mode damage e Instantly clamps differential mode surges induced voltage across the loop detector input terminals via a semiconductor array The array appears as a low capacitance to the detector e Clamps common mode surges induced voltage between the loop leads and ground via solid state clamping devices e Withstand 25 100A surge current occurrences of a 10 x 700 us waveform e Have the following clamp characteristics e Maximum break over voltage e Maximum on stage clamping voltage e Response Time e Off stage leakage current e Capacitance 170 V 3V 5 ns 10 LA less than 220 pf e Ensure that the unit also meets the following minimum requirements e Peak surge cu
32. voltage range of 80 to 135 VAC and the temperature range of 40 C 40 F to 74 C 165 F Provide modules that conform to the applicable portions of section 925 2 15 Ensure the unit provides a minimum Iuuminous intensity of 500 candela and doe not exceed 18 watts at 25 C 77 F Couple the lamp to the diffusing element with a collar including a specular inner surface The diffusing element may be discrete or integral with the convex surface of the optical limiter b Supply an optical limiter with an accessible imaging surface at focus on the optical axis for objects 900 to 1 200 feet 270 to 360 m distance and permit an effective veiling mask to be variously applied as determined by the desired visibility zone Ensure that the optical limiter is provided with positive indexing means and is composed of heat resistant glass c Ensure that the objective lens is a high resolution planar incremental lens hermetically sealed within a flat laminate of weather resistant acrylic or approved equal Supply a lens that is symmetrical in outline and that may be rotated to any 90 degree orientation about the optical axis without displacing the primary image 2 Mounting a Supply signals that mount to standard 1 5 inch 38 mm fittings as a single section as a multiple section face or in combination with other signals Provide signal sections with an adjustable connection that permits incremental tilting from 0 to 10 degrees above or below the horizontal whi
33. wire access is free of burrs and casting webs 5 Ensure that the Wire Entrance opening is recessed and has a neoprene grommet with sealed membrane sections 6 Ensure that the signal head attachment end is serrated and has a minimum of 3 signal head centering bosses extending 0 19 inches 5 mm from the serrations 7 Ensure that the serrations have a 72 tooth design to match the signal head 8 Ensure that three 3 stainless steel studs are cast into the wire entrance fitting Ensure that the studs are 0 31 inches 7 mm and extend 1 5 inches 38 mm 0 13 inches 4 mm beyond the serrations Provide each Tri Stud span wire entrance fitting with a Tri Stud hardware kit 9 Ensure that the Tri Stud Span Wire Entrance Fitting has an alodine conversion coating to provide a proper base for paint adhesion Ensure that the assembly is painted black and baked in a drying oven after painting 10 Ensure that the all Hardware is galvanized or stainless steel Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 48 Bull Rings A Requirements Provide bull rings that are galvanized weldless steel 0 63 inch 16 mm diameter Submit catalog cuts for approval Fabrication General Provisions 101 through 150 79 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment
34. 01 through 150 80 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment C Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 51 Vinyl Electrical Tape A Requirements Ensure electrical tape used is flame retardant cold and weather resistant Provide tape that is rated for 600 volts and for use between 0 F 18 C and 176 F 80 C Ensure tape is 0 0085inches 0 2 mm thick and meets the requirements of UL 510 and Mil I 24391 Provide tape that remains flexible with abrasion resistance Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 52 Ready Access Aerial Splice Closures A Requirements Provide aerial splice closures that are designed for load coil mounting and provide an inner shield bond and ground system to enhance good transmission and sound electrical shield continuity Provide Closures that have numbered drop wire entrances and are of polyethylene construction with stainless steel external parts Provide splice closures that are specifically designed for use with cable taped to messenger strand Ensure the messenger strand is enclosed in the splice closure and the field terminations are protected from the environment Ensure the enclosure has an inner shield
35. 1 6 E and a special aluminum door frame angle For Alloy 6063 T5 ensure that the wall is at least 0 075 inches thick and the corners and joints are at least 0 080 inches 2 mm thick Use filler arc for all welding Ensure all hinges and fastening hardware nuts bolts fasteners on the housing and internal components are stainless steel Use a BR type take apart door hinge and draw bolt Furnish one P 15 1 5 inch 38 mm hub on the top surface Prime the entire case with zinc chromate bake the inside with two coats of non yellowing white and paint the outside with two coats of highway yellow 2 Electrical Ensure that all blankout signs are LED and conform to current ITE Standards Supply all signs with the necessary mounting hardware to provide for mounting as shown on the Plans Provide mounting for one way or two way configurations Obtain approval for messages and letter dimensions from the Engineer 3 Sun Phantom Screen Attach to each sign a heavy duty aluminum louver type sun phantom screen covering the entire sign face Slant the louvers down enough to eliminate the sun glare without obstructing the view of the sign face 4 Painting Paint the signal surfaces inside and out with two coats of oven baked enamel in addition to the primer coat Paint the non illuminated portions of the signal face black Paint the housings brackets fittings and etc highway yellow 5 Lens Use a fabricated three section Plexiglas lens c
36. 29 2070 In 17 19 2 16 1 18 3 32 33 2070 Port 3 2 1 1 3 4 1 3 3 1 1 2 3 3 1 4 l 5 1 5 2 Function Ph1 Det Ph2 Det Ph 3 Det Ph4 Det Ph5 Det Ph6 Det Ph7 Det Ph 8 Det Pd 2 Det Pd 6 Det Fld Term T 712 T 75 6 T 79 10 T 81 2 T856 T 89 0 T 912 T 95 6 T412 T 45 6 SIU Pin B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 SIU Port 2 7 3 1 3 3 3 5 3 7 4 1 4 3 4 5 4 7 5 1 5 3 5 5 SIU In 8 10 12 14 16 18 20 22 24 26 28 30 1 Lower 2070 In 8 4 10 6 9 5 11 7 13 37 34 35 2070 Port 2 1 1 5 2 3 17 2 2 1 6 24 1 8 2 6 5 6 5 3 5 4 Function Ph2Det Ph2Det Ph 4 Det Ph4 Det Ph5 Det Ph6 Det Ph7 Det Ph8 Det Pre2 Pre 4 Pd 4 Det Pd 8 Det Fld Term TS T 73 4 T 77 8 T71112 T 834 T 87 8 11 12 T 934 T 97 8 T 53 4 T578 T434 T 47 8 B26 9 1 Opto In 3 2070 In 47 2070 Port 6 6 Function Fish Sen Int Adv Table 925 17 Required Surge Arrestors for Model 346 ITS Cabinet Field Terminal Block Required Arrestors for Model 346 Cabinet TB 4 Section 925 2 05 A 10 f TB 5 Section 925 2 05 A 10 f TB 5 TERMINAL BLOCK Only Section 925 2 05 A 10 f TB 7 TB 8 TB 9 Section 925 2 05 A 10 c 42 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 925 2 06 Uninterruptible Power Supply UPS System A Requirements This specification is for establishing the minimum requirements for a complete Uninterruptible Power Supply UPS
37. 600 pF Two terminal device one of which is connected to the AC output of the signal load switch on the output file terminals backside of the field terminals with the other connected to AC neutral e Communication Inputs Protect low voltage communications input as it enters the cabinet with a solid state surge protection unit that meets or exceeds these requirements Dual pair 4 wire module with a printed circuit board connector double sided and gold plated for reliability Ability to mate with and be installed in a 10 circuit Buchanan connector Part Number PCB1B10S or Tyco Part Number 2 14378410 3 or equivalent Usable as two independent signal pairs The data circuits pass through the protection in a serial fashion C2 connector of the 2070 controller that terminates on the line side of the unit Communication field wires for this local side that terminate on the line side of the unit Ground terminals connected to power ground Ensure that the unit meets the following minimum requirements Peak surge current 10 kA 8 x 20 us wave shape 500A 10 x 700 us wave shape Occurrences peak 50 typical Response time lt Ins Voltage Clamp 8V line to line Series Resistance 24 Q total Temperature 40 F 40 C to 185 F 85 F Primary protector 3 element gas tube 5kA 8 x 20us wave shape per side Secondary protector Silicon avalance 1 5 kW minimum f Low Voltage DC Inputs Provide an external surge protection device
38. 8 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment D Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 47 Cast Aluminum Tri Stud Span Wire Entrance Fitting A B C D Requirements Ensure that the Tri Stud Span Wire Entrance Fittings are cast from Aluminum Alloy 713 or equivalent free of voids pits dents molding sand and excessive foundry grinding marks Ensure that the all design radii are smooth and intact Ensure that the exterior surface finish is smooth and cosmetically acceptable free of molding fin cracks and other exterior blemishes Ensure that the material is fabricated from aluminum ingot with minimum requirements as follows e ALUMINUM ALLOY No 713 e YIELD STRENGTH ksi MPa 25 172 e TENSILE STRENGTH ksi MPa 35 240 e BRINELL HARDNESS 75 e ELONGATION in 2 inches 50 mm 3 1 Ensure that the Tri Stud Span Wire Entrance fitting has a mounting support at the top of the wire entrance 0 69 inches 17 mm thick 0 07 inches 1 5 mm 2 Ensure that the Tri Stud Span Wire Entrance fitting weight is not less than 1 75 pounds 0 8 kg with hardware 3 Ensure that the mounting support has at least six 6 clevis openings for adjustment with suspension bracing between every two 2 openings 4 Ensure that the Tri Stud Span Wire Entrance has a minimum of 0 5 inch 13 mm diameter throughout for wire access and that
39. 925CL Rev 9 0 DEPARTMENT OF TRANSPORTATION STATE OF GEORGIA SPECIAL PROVISION Project Number P I Number CLAYTON COUNTY Section 925CL Traffic Signal Equipment Delete Section 925 and substitute the following 925 1 General Description This section provides Specifications for a variety of traffic signal equipment Ramp Meters are defined as a form of traffic signalization and all general provisions for traffic signalization are applicable unless otherwise noted in the Plans and Specifications 925 1 01 Related References A Standard Specifications Section 500 Conerete Structures Section 639 Strain Poles for Overhead Sign and Signal Assemblies Section 647 Traffic Signal Installation Section 682 Electrical Wire Cable and Conduit Section 833 Joint Fillers and Sealers Section 861 Piling and Round Timber Section 870 Paints Field Painting Section 915 Mast Arm Assemblies Section 922 Electrical Wire and Cable Section 923 Electrical Conduit Section 926 Wireless Communication Equipment Section 927 Wireless Communication Installation Section 935 Fiber Optic System Section 937 Video Detection System Section 939 Communications and Electronic Equipment B Referenced Documents e National Electrical Manufacturers Association NEMA Standards Publication TS 1 Section 15 e NEMA Standard Publication TS 2 1998 e Institute of Transportation Enginee
40. C Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 49 Ramp Meter Enforcement Device A Requirements For each metered lane provide one ramp meter enforcement device mounted on the back of one signal per lane and wired directly to the red signal display Refer to 647 3 05 L This installation shall include a Red 44 LED Array allnGaP Pixel housing 6061 aluminum powder coated swivel bracket 2 inch lens with an aluminum hood Mounted and adjusted as per the Plans Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 50 Advance Warning Flasher Blank Out Sign A Requirements The Advance Warning Flasher blank out sign shall display the message PREPARE TO STOP and shall have the dimensions shown in the Plans The advance warning flasher blank out sign assembly shall consist of e The legend color shall be double stroke red LED Letters The LED shall conform to the Federal color Standards e The formed letters shall conform to the United States Department of Transportation s Standard Alphabet e Two yellow 12 inches 300 mm traffic signal heads flashing Beacons shall be mounted on each end of the sign as shown in the Plans The Yellow Flashing Beacon will be designed using the 925 2 07 Flashing
41. CA Ensure the PCA indicator illuminates if the Program Card is absent or not properly seated If the unit is in the Diagnostic Display mode ensure the PCA indicator flashes ON once twice or three times to indicate the fault event number being displayed See Subsection 925 2 04 A 15 c RP DETECT Ensure the RP DETECT indicator illuminates when the unit has detected a Conflict Red Fail or Dual Indication fault as a result of recurring pulse field inputs CHANNEL STATUS Ensure that during normal operation the 48 Channel Status indicators display all active signals Red Green and Yellow In the fault mode ensure that the Channel Status indicators display all signals active at the time of the fault for six seconds and then indicate the channels involved in the fault for 2 seconds Front Panel Control Reset Button i ii Provide a momentary SPST Control switch labeled RESET on the unit front panel to reset the monitor circuitry to a non failed state Position the switch on the front panel such that the switch can be operated while gripping the front panel handle Ensure that a reset command issued from either the front panel button or External Reset input is a one time reset input to prevent the unit from constant reset due to a switch failure or constant external input and causes all LED indicators to illuminate for 300 ms The Reset button also provides control of the Diagnostic Display mode For a complete description of Diagn
42. CALTRANS QPL Also see item 4 Testing in Section A above Materials Warranty See Subsection 925 2 01 D for Materials Warranties 925 2 03 Type 2070 Controller Subassemblies A Requirements For 2070 controller subassemblies use 2070 controller subassembly units that meet the requirements of the following or are previously approved by TSEF e Traffic Electrical Equipment Specifications TEES published by the State of California Business Transportation and Housing Agency Department of Transportation current edition and current addenda e CALTRANS Qualified Products List QPL The following Specifications augment the CALTRANS Specifications and take precedence over conflicting CALTRANS Specifications 1 2070 1B Module The 2070 1B module may be supplied as a separate item to be used in all versions of the 2070 controller The 2070 1B module shall be supplied complete with the operating software Ensure it contains the required files to be compatible with the current GDOT applications software 2 2070 IE Module The 2070 1E module may be supplied as a separate item to be used in all versions of the 2070 controller The 2070 1E module shall be supplied complete with operating software Ensure it contains the required files to be compatible with the current GDOT applications software 3 2070 2A Field I O Module The 2070 2A Field I O module may be supplied as a separate item The 2070 2A Field I O module shall consist of
43. Diagnostic Error Multiple Channel Inputs Lack of Signal Inputs Yellow Clearance Yellow plus Red Clearance Police and Power Distribution Switch Monitor door Switches and Main Contactor Status Circuit Breakers Flash Unit Output Status and AC Line Level Sense Ensure the Unit supplied is listed on the most recent California Department of Transportation Qualified Products List QPL The Type 214 AMU shall provide the field signal sensing Current Monitoring Supply Type 214 AMU capable of operating in a 14 channel mode or a 6 channel mode Ensure the address select is correct for the output assembly in which the Model 214 AMU is installed Diagnostics Ensure the Type 214 AMU has self diagnostic tests that execute continuously to provide for correct operation to properly monitor the current for use with LED signal heads 13 Type 218 ITS Serial Interface Unit a Introduction Supply each input and output assembly with a Type 218 ITS Serial Interface Unit SIU Ensure the Type 218 ITS SIU supplied meets the CALTRANS TEES Specifications Ensure the Unit supplied is listed on the most recent California Department of Transportation Qualified Products List QPL The Type 218 ITS SIU shall provide the interface between the 2070 controller and the input and output files Configuration Supply Type 218 SIU capable of operating in all input and output modes Provide a Model 218 SIU that is configured correctly for the input or output file for whic
44. Hardware For Mounting 12 Inch 300 mm Pedestrian Head A Requirements Use hardware as indicated in section 647CL 3 05 DD Pedestrian Signal Heads Ensure the hardware matches the pedestrian head Fabrication General Provisions 101 through 150 Acceptance Ensure this item consists of hardware as shown in the Standard Details This item will be approved upon submittal of catalog cuts Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 27 Pedestal Pole A B C Requirements The Pedestal poles support vehicle signal heads IVDS pedestrian signal heads and push button Furnish Pedestal poles according to type and overall length Pedestal pole for vehicle display for one lane ramp metering operation shall be constructed to support one 12 signal head and one 8 signal head assembly as shown in the Plans Pedestal pole for ramp meter advance warning sign and flashing beacon shall be constructed to meet the sign manufacturer s structural requirements Pedestal pole mounting adapter shall rigidly attach to the sign case s structural bracing Cable entrance to the sign case shall be through the inside of the pole Ensure that all poles are made of one continuous piece of bare finish spun aluminum from top to base connection for the entire height of the pole The shaft of appropriate shape may or may not be uniformly tapered from butt to tip A pole used to support only a traffic sig
45. Messenger amp guy strand 0 38 inch 9 mm as a minimum size Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 41 Power Disconnect Box A Requirements Ensure that all power disconnect boxes are NEMA 3R 240 V AC 60 Amp Phase 1 metal non fused 2 pole Ensure the disconnect box is supplied with a padlock keyed as per directions of District Signal Engineer Provide power disconnect box that is not fused and does not have a circuit breaker Supply with a service grounding kit Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 42 Cable Ties A Requirements Ensure that all cable ties are nylon ultraviolet resistant black and consist of the following as a minimum 76 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Nominal Length 8 inches 200 mm Width 0 30 inches 7 mm Tensile Strength 120 pounds 55 kg B Fabrication General Provisions 101 through 150 C Acceptance General Provisions 101 through 150 D Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 43 Guy Guards A Requirements Ensure that all guy guards are high impact resistant PVC wi
46. NA or 2070 4NB module shall be provided as required in the configuration requirements in the preceding Item In addition to all requirements of the TEES the power supplies shall be clearly marked as a 2070 4A 2070 4B 2070 4NA or 2070 4NB The Vendor may supply a 2070 4A or 4NA power supply module in lieu of a 2070 4B or 4NB as long as it is so marked and adds no additional cost to GDOT or Clayton County 3 Documentation Include with each controller manuals that document the programming operation and maintenance of the unit Include schematic drawings and pin assignment charts in the manuals for maintenance Documentation shall include all components including communications modules Specific reference is made to section 1 2 4 Documentation in the CALTRANS TEES concerning required documentation to be provided 4 Testing Provide for complete testing of unit before it is shipped If unit is shipped with applications firmware installed it must be tested with the application e g Traffic Signal Control If a random sample of greater than 10 percent of the units tested is rejected then the total shipment shall be rejected and vendor will be responsible for all costs to test and repair all units provided 4 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment B Fabrication General Provisions 101 through 150 Acceptance See Subsection 925 2 01 for compliance with
47. Resistance of Thermoplastic Pipe and Fittings by Means of a Tup e ASTM D543 Standard Practices for Evaluating the Resistance of Plastics to Chemical Reagants 2 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 925 2 Materials 925 2 01 General A Requirements Ensure that the traffic signal equipment and materials meet the Plans and Specifications All equipment and materials of like kind and function shall be of the exact same manufacture model revision firmware etc All equipment furnished shall be new and meet the requirements of the following Underwriter s Laboratory Incorporated UL Electronic Industries Association EIA National Electric Code NEC American Society of Testing and Materials ASTM American National Standards Institute ANSD International Municipal Signal Association IMSA National Electrical Manufacturers Association NEMA Applicable Standards Specifications and Regulations of the Clayton County Department of Transportation and Development Traffic Engineering Division 7960 North McDonough Street Jonesboro GA 30236 and Georgia Department of Transportation Traffic Signal Electrical Facility amp NaviGAtor Support TSEF 935 E Confederate Avenue Building 5 Atlanta GA 30316 B Fabrication General Provisions 101 through 150 C Acceptance General Provisions 101 through 150 Materials Warranty Provide to the District Signal Engineer o
48. TM A 475 Siemens Martin grade or better with a Class A coating Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 75 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 925 2 39 Underground Feeder Cable Type UF A Requirements Ensure that underground feeder cable Type UF w ground has two 2 conductors with pvc nylon jacket and a minimum 600 V AC rating per UL 4493 Two conductor No 6 AWG wire may be used Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 40 Messenger amp Guy Strand Span Wire A Requirements Ensure that all messenger and guy strand span wire conforms to ASTM A 475 Extra High Strength grade or better with a Class A coating 7 wire span wire Ensure 4 inch 6 mm Messenger amp guy strand shall be used to support interconnect cable or as tether spans Messenger amp guy strand 0 31 inch 7 mm shall be used only where it is essential to match an existing 0 3 linch 7 mm span wire that will not be replaced as part of a new installation Ensure all span wire for signal heads blank out sign optically programmed heads lane control signs standard aerial or sidewalk guys uses a minimum
49. U Pin B6 B7 B8 B9 B10 B15 SIU Byte Bit 3 1 3 3 3 5 3 7 4 1 4 3 4 7 5 3 5 5 SIU Input 10 12 14 16 18 20 24 26 28 30 2070 Input 4 41 19 2 30 10 52 34 13 39 2070 Port 1 5 6 2 3 4 1 3 4 7 2 3 7 5 5 3 2 6 5 8 Function Ph 2 Det Ph 2 Det Ph 3 Det Ph 4 Det Ph 4 Det Ph 4 Det Sp Det 6 Pd 4 Det Pre 2 Pre 6 Field Term TB 2 7 8 TB 2 11 12 TB 4 3 4 TB 4 7 8 TB 4 11 12 TB 6 3 4 TB 6 11 12 TB 8 5 6 TB 9 11 12 TB 9 8 9 SIU Pin A26 B26 A27 SIU Byte Bit 9 0 9 1 9 2 SIU Input Opto In2 Optoln3 Opto In 4 2070 Input 14 47 45 2070 Port 2 7 6 6 6 8 Function d FishSen jMCE IntAdv ISTO pp n suPn 5 m w JA9 Tao latt M2 1A3 aa aas At6 Pin A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 SIU Byte Bit 2 6 3 0 3 2 34 3 6 4 0 4 2 4 4 4 6 5 0 5 2 5 4 SIU Input 7 9 11 13 15 17 19 21 23 25 27 29 2070 Input 16 1 29 9 18 7 44 54 49 33 36 15 2070 Port 3 1 1 2 4 6 2 2 3 3 1 8 6 5 7 7 7 2 5 2 5 5 2 8 Function Ph5Det Ph6Det Ph6Det Ph6Det Ph7Det Ph8Det Ph8Det SpDet3 SpDet7 Pd6Det Pre3 Spare 1 Field Term TB 3 1 2 TB 3 5 6 TB 3 9 10 TB 5 1 2 TB 5 5 6 TB 5 9 10 TB 7 1 2 TB 7 5 6 TB 7 9 10 TB 8 7 9 TB 9 4 6 TB 8 1 3 SIU Pin B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 SIU Byte Bit 2 7 3 1 3 3 3 5 3 7 4 1 4 3 4 5 4 7 5 1 5 3 5 5 SIU Input 8 10 12 14 16 18 20 22 24 26 28 30 2070 Input 20 5 42 18 3 31 11 55 50 35 37 40 2070 Port 3 5 1 6 6 3 3 3 1 4 4 8 2 4 7 8 7 3 5 4 5 6 6 1 Function Ph5Det Ph6Det Ph6Det Ph7Det
50. ackside of the field terminals with the other connected to AC neutral d Communication Inputs Protect low voltage communications input as it enters the cabinet with a solid state surge protection unit that meets or exceeds these requirements 36 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment e Dual pair 4 wire module with a printed circuit board connector double sided and gold plated for reliability e Ability to mate with and be installed in a 10 circuit Buchanan connector Part Number PCB 1B10S or Tyco Part Number 2 1437410 3 or equivalent e Usable as two independent signal pairs e The data circuits pass through the protection in a serial fashion e C2 connector of the 2070 controller that terminates on the line side of the unit e Communication field wires for this local side that terminate on the line side of the unit e Ground terminals connected to power ground e Ensure that the unit meets the following minimum requirements Peak surge current 10 kA 8 x 20 us wave shape 500A 10 x 700 us wave shape Occurrences peak 50 typical Response time Ins Voltage Clamp 8V line to line Series Resistance 24 Q total Temperature 40 F 40 C to 185 F 85 F Primary protector 3 element gas tube 5kA 8 x 20us wave shape per side Secondary protector Silicon avalance 1 5 kW minimum Low Voltage DC Inputs Provide an external surge protection device for each low voltage DC inp
51. al and meets current related ASTM Specifications Ensure that all configurations are balanced to provide a plumb hanging unit Ensure that all components are readily and easily accessible from the open door Housing door Ensure that the housing door is one piece corrosion resistant aluminum or polycarbonate and meets current related ASTM Specifications Provide two substantial door hinges with stainless steel hinge pins Ensure hinges are on the left side of each section with a latch boss on the right side Provide stainless steel dual eye bolt latches or similar approved devices to securely close and latch the housing door Equip the housing or door with a continuous molded neoprene gasket to make the interior of the unit dustproof and waterproof Wiring Provide each signal housing with a complete terminal board Ensure that one side of terminal strip accommodates socket leads and the other side accommodates field wires Ensure that the terminal board provides totally separate wiring of each symbol Ensure each lamp is separately wired to a terminal block located in each housing Provide each lamp holder socket with color coded leads For combination symbols color code socket leads separately to distinguish between red X yellow X or downward arrow symbols Provide leads that are No 14 AWG type THW 600 V AC and fixture wire with 194 F 90 C thermoplastic insulation Visors Provide visors not less than 12 inches 300 mm lo
52. al module light output The failure of a single LED in a string causes loss of light from only that LED not the entire string or indication Provide control circuitry that prevents the current flow through the LEDs in the off state to avoid any false indications as may be perceived by the human eye during daytime and nighttime hours Ensure that the LED signal module is operationally compatible with existing or new supplied conflict monitors NEMA TS 1 NEMA TS 2 Model 210 Model 2010 ITS Cabinet CMU and AMU Ensure that the LED Signal Module is operationally compatible with existing or new supplied load switches Ensure that the intensity of the LED signal module does not vary by more than 1046 over the allowable voltage range as specified in the electrical section below Ensure that the LED signal modules maintain not less than 90 of the required intensity as defined by the ITE intensity Standards for LED traffic signal modules Ensure that each module provides an average luminous of at least 3750 candela per square meter of lighting surface for the Hand and 5300 candela per square meter for the Man symbol Ensure this over the temperature range of 40 F to 165 F 40 C to 74 C at 120 V AC when new and after four 4 years of field installation Provide an exterior lens which is uniform and frosted to reduce sun phantom effect 3 Electrical Supply LED signal modules that operate over the temperature range of 40
53. anagement System Application shall include Model 212 CMU and two Model 216 Power Supply Units and attached harnesses c Model 340 Cabinet Field termination panels 9 Flash Transfer Relays 2 Model 204 Flashers 33 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Specific Equipment Layout and other cabinet devices determined on a project specific basis d Model 342 Cabinet 2 Model 242 DC Isolator 6 Flash Transfer Relays 2 Model 204 Flashers e Model 346 Cabinet 2 Model 242 DC Isolator 6 Flash Transfer Relays 2 Model 204 Flasher 1 M Base Adapter installed Base Mount Cabinets Only 1 Aluminum Cover Plate for Cabinet Bottom Pole Mount Cabinets Only f Model 354 Cabinet Specific Equipment Layout and additional cabinet equipment determined on a project specific basis g Model 356 Cabinet Specific Equipment Layout and additional cabinet equipment determined on a project specific basis 1 M Base Adapter installed Base Mount Cabinets Only Aluminum Cover Plate for Cabinet Bottom Pole Mount Cabinets Only Note Include above components in cabinet at time of delivery Other auxiliary cabinet components such as controllers load switches etc will be ordered as separate items 2 Finish Use cabinets that have a bare aluminum finish see Subsection 925 2 07 A 1 for controller cabinet minimum fabrication specifications 3 Locks Equip the main cabinet door with loc
54. bonding system with a clamping arrangement that shield the cable 360 degrees in circumference to provide shield continuity Provide splice enclosure of the appropriate size to support the correct cable diameter Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 53 Internally Illuminated Street Sign Assembly A Requirements This specification covers the materials to provide and install internally illuminated street sign lighted street name sign assemblies as indicated in the plans and details The assembly shall include the lighted street name signs the termination panel sub assembly the photo cell sub assembly and other materials necessary for the sign operation 1 Internally Illuminated Street Signs Lighted Street Name Signs a Mechanical 1 The outer dimensions of the sign assembly excluding the mounting bosses shall be standard height of 18 inches 45 7 cm and standard widths of 48 96 inches 46 7 to 244 cm at 6 inch 15 2 cm increments 81 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 2 The maximum thickness of the sign shall be 1 5 inches 3 81 cm for single sided signs and 2 inches 5 cm for double sided signs excluding the end caps 3 The long edges of the sign shall be made from a single section of Aluminum extr
55. ce with CALTRANS TEES and the following Provide monitor that is on the CALTRANS QPL and provides the pin assignment as shown in Table 925 3 The Model 208 Monitor Unit shall reliably sense and cause a relay output contact FAILED STATE when monitoring the following A Watchdog Timer WDT Timeout Condition Cabinet 24 VDC Power Supply below specified threshold a WDT Monitor Requirements WDT Circuitry shall be provided to monitor a controller unit output line state routed to the monitor unit at its assigned pin The WDT Circuitry shall sense any line state change and the time between the last change No state change for 1 5 0 1 seconds shall cause a FAILED state The timer shall reset at each state change in a NON FAILED state 1 2 3 Only the Unit Reset or a WDT inactive due to the voltage sense shall reset the WDT from a FAILED state A FAILED state caused by the WDT shall illuminate a front panel indicator light label WDT ERROR The indicator shall remain ON until Unit Reset Issuance The WDT Circuitry shall sense the incoming VAC Line and when the voltage falls below 98 2VAC for 50 17 ms shall inhibit the WDT Function When the WDT Circuitry sensed the incoming VAC Line rise above 103 2VAC for 50 2ms the WDT shall become active A hysteresis between the Voltage Inhibit and the Voltage Active Setting shall be a minimum of 3 Volts c Power Supply Monitor Requirements 1 2 3 4 5 6 7 The
56. ck typ Un Bett Low Batt Timer Oo Ol Terminal Block NO C NC NO C NC NO C NC Notes 1 NO NC contacts may either share or use separate commons Operating temperature for both the UPS and the batteries shall be 37 C to 74 C 43 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment f Upon loss of of utility power the UPS shall insert the battery power into the system via the the Power Interface Module PIM The PIM will ensure that the UPS will drop out and upon return of utility power default to normal operating mode The PIM shall ensure this even when the UPS fails or the batteries are depleted g The UPS shall use a temperature compensated battery charging system The charging system shall compensate over a range of 2 5 4 0 mV C per cell The temperature sensor shall come with 3 meters 10 feet of wire h Batteries shall not be recharged when battery temperature exceeds 50 C 3 C i UPS shall be compatible with CALTRANS Model 332A Cabinets CL4D Cabinets Model 170E Controllers Model 2070 Controllers and cabinet components for full time operation j UPS shall be equipped to prevent a malfunction feedback to the cabinet or from feeding back to the utility service k Recharge time for the battery from protective low cutoff to 8096 or more of full battery charge capacity shall not exceed twenty 20 hours 1 The Bypass switch shall enable removal and rep
57. compassing the top and sides of the signal face of a size and shape adequate to shield the lens from external lighted sources An acceptable option is a Z crate or louver type visor for mounting over the Pedestrian signal face Construct the housing of one piece cast aluminum alloy with two integrally hinge lugs screw slots and openings at each end Construct the door of one piece cast aluminum alloy with two hinge lugs cast on top of the door and two latch points cast on the bottom Provide hinge pins of stainless steel to attach the door to the housing and two eye bolts and wing nuts on the other side of the door Ensure that the door is provided with a neoprene gasket capable of making a weather resistant dustproof seal when closed Supply Pedestrian signal heads with a black face and body unless otherwise specified on the Plans Ensure that Pedestrian indications are distinguishable to the Pedestrian both day and night and at all distances from 10 feet 3 m to the full width of the areas to be crossed Supply Pedestrian indications that are rectangular in shape and consist of the HAND amp PERSON symbol Use symbols that are 12 inches 300 mm high Use only internal illumination Ensure that when illuminated the HAND symbol is Portland Orange and the PERSON symbol is Lunar White meeting the ITE Standards Ensure that an opaque material obscures all areas of the face or lens except for the message Ensure that when no
58. connector above or to the right of the Buchanan terminal block Cabinet Model 346 Base Mount This unit meets the CALTRANS Specification with the addition of approximately 6 additional inches 150 mm of cabinet height exclusive of the M base adapter Configure the internal component layout so that the additional space is available in the bottom area of the cabinet cage Ensure that the field wiring input panels and surge protection conform to Table 925 16 Model 346 ITS Cabinet Default Input File Assignment Detail Table 925 17 Required Surge Arrestors for Model 346 Cabinet and Table 925 15 Model 342 amp 346 Default ITS Cabinet Default Output File Assignment Cabinet Model 346 Pole Mount Ensure that this unit meets the requirements of Subsection 925 2 04 A 19 above except that the cabinet is configured for pole mounting as specified in the General Requirements for Type ITS Cabinet Assemblies Cabinet Model 340 The Model 340 cabinet configuration will be determined by the special provisions of the project Ensure that the input and output port assignments are compatible with the 2070 controller as applicable according to the required number of input outputs Ensure that the 340 cabinet uses standard ITS cabinet input and output file units Equip the cabinet with a C2 connector harness with field terminals protected with surge protectors for communication inputs as specified under communications inputs Ensure that the cabi
59. current AC Line voltage if the monitor is not in the fault state or the AC Line voltage at the time of the fault e Control Input Status the current state and RMS voltages of the Red Enable input EE input and Special Function 1 and 2 inputs if the monitor is not in the fault state or the status latched at the time of the fault 2 Previous Fault Log PF Ensure the Previous Fault log contains the following information a Fault Type the fault type description b Field Status the latched field status with RMS voltages and fault channel status at the time of the fault c Cabinet Temperature the latched temperature at the time of the fault d AC Line Voltage the AC Line voltage at the time of the fault e Control Input Status the latched state of the Red Enable input EE input and Special Function 1 and 2 inputs at the time of the fault 3 AC Line Event Log AC The AC Line log shall contain the following information a Event Type describes the type of AC Line event that occurred e Power up AC on monitor performed a cold start e Interrupt AC Line lt Brownout level e Restore AC restored from brown out or interruption AC Off no cold start b ACLine Voltage the AC Line voltage at the time of the event 4 Monitor Reset Log MR Ensure the Monitor Reset log contains the following information a The monitor was reset from a fault by the front panel Reset button or External Reset in
60. door opening will provide an input to the controller through the C115 I O connector Provide a wiring harness connecting the C11S connector on the 2070 2A Field I O Module C118 connector with a dedicated terminal block The C11 harness connector shall be fully wired to all pins in the connector Provide a minimum 14 position two row dual screen barrier type terminal block and configure the all conductors in the harness to reach any position on the terminal block Terminate assigned harness conductors as shown below Individually insulate and wrap all unassigned conductors 5 me mou 1 e sam 2 mr umsmarmvon 0 37 dm SeEALSIMUSS gt 3 sam nm CJ se sm fn Provide the cabinet ventilation fan with a minimum capacity of 200 cubic feet of free air delivery per minute The fan thermostat shall be set at its lowest limit or 70 degrees F which ever is greater Provide each of the two cabinet doors with an intake and filter as specified in Subsection 6 2 7 1 of the AASHTO ITE NEMA ITS Cabinet Standard specification Configure the cabinet for dial up communications Mount a two 2 circuit Buchanan connector on the right side panel from rear door Mount a phone jack with a RJ11 connector above or to the right of the Buchanan terminal block Wire the phone jack to the Buchanan and to the Terminal Block TBO in accordance with Figure 925 3 A manual jack shall be installed inside the pol
61. duit terminators for Sch 40 and SDR11 2 inch 53 mm of the quantity and location as shown in the Plans or for a different conduit size if shown in the Plans Terminator bodies shall be manufactured from high impact polystyrene or approved equivalent When joining conduits of dissimilar materials furnish an airtight and watertight conduit adhesive intended for direct contact underground use Refer to the Standard Detail Drawings and the Traffic Signal Design Manual for further information Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 34 Prefabricated Controller Cabinet Base A Requirements Provide controller cabinet bases as shown in the Plans that are precast polymer concrete and grey in color Ensure the prefabricated controller cabinet base has the correct bolt pattern and threaded UNC inserts for the cabinet s to be installed UNC inserts shall be stainless steel and be designed for a minimum of 15 foot pounds of torque Ensure that prefabricated controller cabinet bases are designed to withstand wind loading of 125 mph 200 km h with the cabinets as shown in the Plans mounted Ensure that prefabricated controller cabinet bases are designed for a minimum static vertical load of 5 000 pounds over a 10 inch by 10 inch by 1 inch thick distribution plate and withstand a tested load of 7 500
62. e a 7 degree cutoff left of center Provide twelve inch 300 mm louvers with 5 vanes Finish all louvered surfaces in flat black Ensure that programmable louvers are directional with a 7 degree cutoff and that all louver surfaces have a flat black finish Ensure that the units can be installed and programmed in accordance with the manufacturer s instruction on visors that are recommended by the manufacturer Have the programmable louver display approved by the Engineer prior to placing the signal in stop and go operation If special tools are required for louver adjustment one shall be provided per project Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 23 Hardware For Mast Arm Mounting A Requirements Ensure that signal heads are rigidly mounted to the mast arm Provide mounting hardware that is in accordance with the following 1 Adjustability Ensure the mounting bracket is completely adjustable such that it allows rotational adjustment about the bracket axis vertical adjustment rotational adjustment about the Mast Arm and rotational adjustment from the vertical plane 2 Attachment Ensure the bracket is provided with air craft grade galvanized steel cables with stainless steel fastening hardware and make a minimum of two wraps around to fasten the bracket to the arm Ensure the bracket is
63. e of illumination from darkness to 10 750 lux and damped for any decrease from 10 750 lux Ensure that the intensity controller is comprised of an integrated directional light sensing and regulating device interposed between lamp and line wires Ensure that it is compatible with 60 Hz input and responsive within the range 105 to 135 V AC Output may be phase controlled but ensure that the device provides nominal terminal impedance of 1 200 open circuit and a corresponding holding current B Fabrication General Provisions 101 through 150 C Acceptance General Provisions 101 through 150 D Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 57 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 925 2 15 LED Signal Modules A Requirements This specification covers Type 1 Light Emitting Diode LED red green and yellow modules for vehicle signals for both Circular and Arrow indications It also covers LED Pedestrian Hand Person and Countdown signal modules 1 General Requirements All Modules Ensure that Type LED signal module include a LED circuit board with LEDs and required circuit components 36 inch 900 mm 16 AWG wire leads with strain relief and spade terminals a rigid housing and a one piece neoprene gasket Supply Type 1 LED signal modules that are watertight when mounted in the traffic signal housing Submit life data on the LEDs from
64. e while a frame is in the transmit queue Table 925 2 RJ45 Pinout and Signal Identification Pin Signal 10 100BaseTx 18 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Unused Unused Rx Unused Unused ojl SI DA GJ BJ NJ 3 Electronics a b c d e 2 h RMS Voltage Sampling Use high speed sampling techniques to determine the true RMS value of the AC field inputs Sample each AC input at least 32 times per cycle Ensure that the RMS voltage measurement is insensitive to phase frequency and waveform distortion Internal MPU Watchdog Use a microprocessor for all timing and control functions Verify continuing operation of the microprocessor by an independent monitor circuit that forces the Output Relay to the de energized fault state enable the Stop Time output and illuminate the DIAGNOSTIC indicator if a pulse is not received from the microprocessor within 300 ms If the microprocessor should resume operation ensure the Signal Monitor continues to operate Ensure that this monitoring circuit is also configurable to latch in the fault state Ensure the unit requires a power up cycle to reset the circuit once it is triggered Sockets In the interest of reliability ensure that only the PROM memory device for the microprocessor firmware is socket mounted Ensure that the PROM memory socket
65. eak surge current 6 times Differential mode 400 A 8 x 20 ms Common mode 1 000 A 8 x 20 ms Estimated occurrences 500 amp 200A Response time 40 ns Input capacitance 35 pF typical Temperature 40 F to 185 F 40 C to 85 C Mounting No 10 32 x 3 8 inch No 5 x 10 mm bolt Clamp voltage 400 A diff Mode 30 V max 1 000 A comm Mode 30 V max c Signal Load Switches Switchpacks Provide the output of the switchpack in the output file with transient protection via the nine position transient protection device in the output file Protect switchpacks from surges on the AC output lines Ensure that the transient protectors meet or exceed these requirements e Steady state sinusoidal voltage RMS rating at 50 to 60 Hz of at least 150 V at 77 F 25 C e Steady state applied DC voltage rating of at least 200 V at 77 F 25 C e Transient energy rating is of at least 80 J for a single impulse of 10 1 000 us current waveform at 77 F 25 C e Peak current rating of 6 500 A for a single impulse of 8 20 us waveform with the rated continuous voltage applied e Varistor voltage of at least 212 V at 1 0mA of DC current applied for the duration of 20 us to 5s e Clamping voltage of at least 395 V with an applied 8 20 us impulse of 100 A e Typical capacitance at a frequency of 0 1 to 1 0 MHz of 1600 pF e Two terminal device one of which is connected to the AC output of the signal load switch on the output file terminals b
66. eld connections Properly label all field terminal connections 6 Construction Assemble the flasher assembly terminal block surge arrestor and circuit breaker in the cabinet as shown on the attached drawing Wire all components together as a working unit thus requiring only field connections to and from the AC power and flashing beacons B Fabrication Refer to Subsection 925 2 07 A 1 for controller cabinet minimum fabrication specifications C Acceptance General Provisions 101 through 150 D Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 08 Flashing Signal Cabinet With Time Clock A Requirements This specification is for a flashing signal cabinet with time clock which consists of an aluminum cabinet containing a flasher assembly time clock field connection terminal block surge arrestor and circuit breaker wired in a manner to operate school flashing beacons Refer to Figure 925 8 49 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment o o o0 TB 0000 E o oO O Note Front view of cabinet Door Assembly not shown No scale Figure 925 8 Typical Flashing Cabinet with Time Clock Cabinet Layout Cabinet Supply a NEMA Type 3R cabinet assembly that is manufactured of aluminum with a minimum thickness of 0 125 inches 3 mm Ensure that the cabinet exterior has a smooth uniform natural aluminum finish and that all joint
67. ely marked as a 4B or 4A module 2070 ANB Power Supply Module The 2070 4NB Power Supply Module may be supplied as a separate item and is an independent self contained module Ensure that it is vented and cooled by convection only Provide module that slides into power supply compartment from the back of the chassis and is attached to the Backplane mounting surface by its four TSD 3 Devices Ensure the module supplies at least 3 5 amperes of SVDC Ensure the 2070 4B Power Supply Module is compatible with Models 2070 LN1 and 2070 LN2 Controller Assemblies and is compatible with current GDOT applications software Ensure the connection harness PS 2 on existing units can be mated with the 4B module supplied Ensure the 4NB power supply module supports the NEMA TS1 and TS2 Standards A 2070 4A Power Supply Module may be provided in place of a 4B module as long as it is labeled as such and there is no additional cost to GDOT or Clayton County Ensure the module supplied is appropriately marked as a 4ANA or 4NB module 2070 6B Communications Module The 2070 6B Communications Module is supplied as a separate item The 6B communications module is a dual async modem serial module Ensure the module supports both Serial and modem FSK communications on both of two separate ports Ensure the Modem data baud rate supports 0 to 9600 Ensure the module is configured to support FSK communications on the C2S connection Ensure it contains any configuration jumpers t
68. en either input is sensed active Ensure that a Special Function input is sensed active when the input voltage exceeds 70 Vrms Ensure that a Special Function input is sensed not active when the input voltage is less than 50 Vrms A Special Function input may or may not be sensed active when the input voltage is between 50 Vrms and 70 Vrms Use a PCB mounted switch to provide the option to invert the active status of the Special Function 1 input When the switch is in the ON position ensure that the Special Function 1 input is sensed not active when the input voltage exceeds 70 Vrms Ensure that the Special Function 1 input is sensed active when the input voltage is less than 50 Vrms The Special Function 1 input may or may not be sensed active when the input voltage is between 50 Vrms and 70 Vrms d Red Interface Connector This connector provides the required inputs for the unit to monitor the Red field signal outputs Ensure the connector is a 20 pin connector that mates with the P20 Cable from the output file Provide a high quality connector that is polarized to insure proper mating with the cable Ensure Ejector latches are included to facilitate removal and prevent the cable from inadvertently disconnecting Ensure the unit shall function as a standard 210 Signal Monitor when the cable is disconnected Use the pin assignments shown in Table 925 1 16 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equip
69. ence of an active voltage on the green and yellow and red field signal inputs of a channel Red Fail fault RED FAIL shall be a latching fault Ensure that the Red Fail monitoring function is enabled for all channels except when the Red Enable input is not active or pin ZEE is active or Special Function 1 input is active or Special Function 2 input is active a Red Fail Recognition Time Ensure the Signal Monitor triggers when an active voltage on one of the three inputs of a channel are absent for more than 1500 ms Ensure that the Signal Monitor does not trigger when an active voltage on one of the three inputs of a channel are absent for less than 1200 ms Channels without proper voltages sensed for more than 1200 ms and less than 1500 ms may or may not trigger the unit Provide an option switch RF 2010 which will change the fault recognition time to between 700 ms and 1000 ms b Red Interface Cable Fault Ensure a programming option is provided such that operating without the Red Interface cable installed shall cause the Signal Monitor to enter the fault mode causing the Output relay contacts to close and enabling the Stop Time output to the controller To indicate this fault mode ensure that the Red Fail indicator is illuminated with all fault channel indicators off Ensure that any Red Fail preemption control to the monitor uses the Special Function inputs 1 or 2 Dual Indication Monitoring Ensure that the Signal Monitor is ab
70. ental 1 The sign shall be designed and constructed to withstand 110 mph wind loads in conformance with the requirements of the AASHTO publication Standard Specifications for Structural Supports of Highway Signs Luminaries and Traffic Signals 4th Edition 2001 2 The sign and power supply should be able to withstand and operate at temperature extremes of 40 deg F to 140 deg F 40 C to 60 C c Luminance 1 The entire surface of the sign panel must be evenly illuminated with a minimum average brightness reading at the letters of 300 lux and a variation of no more than 40 between maximum and minimum 2 The light transmission factor of the sign panel must provide a letter to background ratio of a minimum of 4 1 d Light Source 1 The light source for the sign shall be LEDs light emitting diodes LEDs shall be mounted along both the top and bottom edges of the sign The LEDs shall evenly illuminate a light panel that is the same dimensions of the sign face 2 The LEDs shall have a minimum projected life of 50 000 hours e Sign Power Supply The power supply shall be housed inside at end cap and shall be accessible Power supply shall be UL Class 2 limited output voltage and current plus isolation for safe operation and UL Outdoor damp location rated Power supply shall be IP66 Outdoor Rated Sign shall be UL listed and approved f Energy Requirements The overall power required shall not exceed 4 Watts per square foot 2 Photo Ce
71. entarily Ensure that the channels reset remotely when the voltage on Pin C falls below 8 V DC for a period gt l5us and that the unit resumes normal operation within four 4 seconds after the application of power or after a reset signal of 15 us k Field Tuning Ensure that field adjustments to the operation of the detector do not require the use of a meter circuit changes special software or any substitutions modifications or additions to the unit 3 Performance Requirements If testing should be required provide the County with a test unit and or software within ten 10 calendar days of the request Should the unit fail to meet the design and or performance requirements of this specification the unit will be rejected Ensure that the units meet the following requirements 53 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment a Capable of detecting passage holding presence and accurately counting all types of licensed motor vehicles when connected in various loop configurations and lead in combinations without detecting vehicles in adjacent lanes e Typical Loop Configurations with Lead in of 5 feet 1 5 m to 1 500 feet 1000 m are e 6feetx 6 feet 1 8 mx 1 8 m e 6feetx 20 feet 1 8 m x 6 m e 6 feet x 40 feet 1 8 m x 12 m standard or quadrupole b Capable of responding to an inductance change of 0 02 and sense vehicles at speeds of up to 80 mph 130 km h c Notdetect vehicle
72. es resistor resident on unit The PDA Type 3 WDT Reset Input shall not be sensed by the unit 20 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 4 The output relay CONTACT FOR FAILED STATE shall be OPEN Table 925 3 Pin Assignments For Model 208 Monitor Unit PIN FUNCTION 1 44 DC Ground 2 43 WDT Ext Reset 5 40 WDT IN 10 35 24 VDC AC Normally Open Circ 2 AC Normally Closed Circ 1 Circ Common 1 amp 2 WDT Lamp External NOTE Card connector keyed between pins 2 amp 3 and pins 11 amp 12 16 Model 242 DC Isolator 20 Provide Model 242 DC Isolators that are in accordance with the latest version of CALTRANS Specifications as referenced earlier in this section Provide isolators that e Allow the 242 isolator input signal polarity to easily be inverted without the use of tools Acceptable methods are removable jumpers or dip switches Unacceptable methods are soldering or desoldering a diode or resistor e Output is OFF for input voltages greater than 12 volts e Output is ON for voltages of less than 8 volts that have a duration of at least 5 to 25 ms optional 2 7 ms e Minimum output pulse width is 100 ms with a valid input can be disabled e Output is optically isolated open collector NPN transistor e Capable of sinking 50 ma when on e Can register a new input within 25 ms of the old signal going away and e Outp
73. escribed in Subsection 925 2 04 A 15 f Monitor Functions Except for Conflict faults compute all fault timing for each channel individually 1 Conflict Monitoring Ensure that the Signal Monitor is able to detect the presence of conflicting green or yellow signal voltages on the AC field terminals between two or more non compatible channels A Conflict fault CONFLICT shall be a latching fault 2 Conflict Recognition Time Ensure the Signal Monitor shall trigger when voltages on any conflicting channels are present for more than 500 ms Ensure that the Signal Monitor does not trigger when voltages on any conflicting channels are present for less than 200 ms Conflicting signals sensed for more than 200 ms and less than 500 ms may or may not trigger the unit 3 24VDC Monitoring VDC Ensure that the Signal Monitor is able to detect that the cabinet 24 Vdc supply has fallen below 18 Vdc A 24VDC failure VDC FAIL shall be a latching fault 4 24VDC Recognition Time Ensure that the Signal Monitor shall trigger when the voltage on the 24V input is below 18 Vdc for more than 500 ms Ensure that the Signal Monitor does not trigger when the voltage on the 24V input is below 18 Vdc for less than 200 ms A voltage level of 22 Vdc will be required to prevent the unit from triggering 5 Controller Watchdog Monitoring Ensure that the Signal Monitor triggers when the Watchdog input does not toggle within the programmed time period
74. et configuration Supply cabinets in accordance with the following information and table 925 12 a Cabinet Traffic Signal Application Series 340 e 340 4 Door Cabinet with P Base Ground Mount e 342 2 Door Cabinet with 170 Base 332 Ground Mount e 346 2 Door Cabinet with 170 Base 336S Adaptor Mount b Cabinet Traffic Management Application Series 350 e 354 2 Door Cabinet with 170 Base 332 Ground Mount e 356 2 Door Cabinet with 170 Base 336S Adaptor Mount Table 925 12 ITS Cabinet Configurations Items ITS Cabinet Versions Housing 1 Cage 1 Housing 2 Cage 2 Housing 3 Two Cage 1 J Panel Cage 1 J Panel Cage 2 Service Panel Assembly with AC EG Bus Raw Clean AC power Assembly Raw Clean AC power Extension AC Clean Module Assembly DC Power Comm Assembly DC Power Comm Extension Cabinet Shelf Assembly Input Assembly Six Pack Output Assembly Fourteen Pack output Assembly PDA ITS Assembly Control Serial Bus harness wl gol wl pol NI NI a a a Serial Bus 3 Harness Note Input Assembly shall include a Model 218 SIU Output Assembly shall include a Model 218 SIU Model 214 AMU and Model 205 Transfer Relays The PDA ITS Traffic Signal Application shall include two Model 204 Flasher Units Model 212 CMU and two Model 216 Power Supply Units and attached harnesses The PDA ITS Traffic M
75. et will transfer from flash to signal operation 14 wm c Display Functions Ensure that it is possible to view the active channels for each individual color GYR during operation and when latched in a fault state When the Signal Monitor is latched in a fault state ensure that it is also be possible to view the active channels for each individual color and fault status for each channel for the current fault and the two previous faults 1 Previous Fault GYR Display When the Signal Monitor has been triggered by a fault the channel status display will alternate between the channels which were involved in the fault fault status for 2 seconds and the field signals active at the time of the fault for 6 seconds The channels involved in the fault will flash their respective Green Yellow and Red indicators simultaneously at a 4 Hz rate for the 2 second interval The two previous faults may also be displayed individually This status is not reset by an AC Line power interruption To enter this display mode remove the Program Card The sequence is as follows Reset Event PCALED Fault Status LEDs Channel Status LEDs 1 Single flash Current Fault Status newest Current Field status 1 2 Double flash Event 2 Fault Status Event 2 Field status 2 3 Triple flash Event 3 Fault Status oldest Event 3 Field status repeats back to top 14 of 84 Office of Traffic Safety amp Design Section 925CL
76. ethane Sealant for Inductive Loops OPL 75 e American Society of Testing and Materials ASTM A36 Standard Specification for Carbon Structural Steel e ASTM A33 Standard Specification for Pipe Steel Black and Hot Dipped Zinc Coated Welded and Seamless e ASTM A123 Standard Specification for Zinc Hot Dip Galvanized Coating on Iron and Steel Products e ASTM A153 Standard Specification for Zinc Coating Hot Dip on Iron and Steel Hardware e ASTM A325 Standard Specification for Structural Bolts Steel Heat Treated 120 105 ksi Minimum Tensile Strength e ASTM A475 Standard Specification for Zinc Coated Steel Wire Strand e ASTM A572 Standard Specification for High Strength Low Alloy Columbium Vanadium Structural Steel e ASTM C1028 Standard Test Method for Determining the Static Coefficient of Friction of Ceramic Tile and Other Like Surfaces by the Horizontal Dynamometer Pull Meter Method e ASTM D256 Standard Test Methods for Determining the Izod Pendulum Impact Resistance of Plastics e ASTM D543 Standard Practices for Evaluating the Resistance of Plastics to Chemical Reagents e ASTM D638 Standard Test Methods for Tensile Properties of Plastics e ASTM D785 Standard Test Method for Rockwell Hardness of Plastics Electrical Insulating Materials e ASTM D790 Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials e ASTM D2444 Standard Test Methods for Determination of the Impact
77. face for EIA 232 Also provided shall be Full Interactive Remote Computer Monitoring and Control for programable features Including EIA 232 Load Control using NTCIP and TCP IP via Standard RJ45 Connector The manufacturer shall provide software to access the Signal Monitor status and event logs This software shall operate with Microsoft WindowsXP WindowsVista Windows7 and Windows8 The communications software running on the PC shall be able to search the network and display a list of IP addresses and Monitor IDs of monitors responding on the network The communications software shall also be capable of making changes to the monitor network parameters such as IP address and subnet mask Monitoring software required for remote monitoring and control shall be provided at no additional cost UPS shall be provided with management hardware by an internal SNMP HTTP adapter This adpater shall provide management functions and monitoring through a standard web browser and through remote monitoring and management software Provide the remote monitoring and management software as part of the project The management adpater shall support an ethernet interface and provide the folowing e Firmware upgrades e UPS shutdown warning e Full history logs e Scheduling functions e Realtime monitoring 4 Battery System a Individual batteries shall be 1 Voltage rating 12V type 2 Group size 24 maximum 41 amp hour Minimum 3 Batteries shall be easi
78. fferent day plans and minimum twenty five 25 different annual exception plans Temperature range of 30 F 34 C 165 F 74 C B Fabrication General Provisions 101 through 150 C Acceptance General Provisions 101 through 150 D Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 10 Self Tuning Loop Detector A Requirements This specification sets forth the minimum acceptable design operational and functional performance requirements for multi channel inductive loop vehicle detection systems 1 General Requirements a Mounting Ensure that the unit is configured for rack mount insertion into a NEMA TS 1 or TS 2 card rack and or CALTRANS Type 2070 cabinet input file Environmental Ensure that the unit is in full compliance with the environmental tests transient tests and size requirements of NEMA standard TS I Section 15 TS 2 Section 6 5 and the California Type 2070 Specifications Provide documentation from an independent laboratory which certifies that the unit is in compliance with the above Specifications LED Indicator Ensure that each channel includes two high visibility LED indicators one for the detect state and the second to indicate the status of the fault monitor Phase Indicator Ensure that each channel has an erasable write on pad to aid in identification of the associated phase or function 2 Operational Requirements a Tuning Supply units tha
79. g the back plate perimeter Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 21 Signal Head Visors A Requirements Typically visors are one piece tunnel type and removable unless specified otherwise in the signal Plans Ensure that visors are polycarbonate and at least 9 inches 225 mm deep for 12 inch 300 mm heads Special angle visors are full circle with the long side at least 18 inches 450 mm deep Ensure that visors provide a positive method of 67 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment attaching to the door of the signal head that do not allow rotation An acceptable method is to provide tabs that use stainless steel screws Unless otherwise specified by the Engineer provide black signal head visors If special tools are required for visor adjustment provide one set per project Coordinate delivery of tools with County Signal Engineer Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 22 Signal Head Louvers A Requirements Ensure that louvers with the vanes oriented vertically are directional with a 7 degree cutoff right of center Rotating the louver 180 degrees will produc
80. h it is supplied Programming Ensure programming of the Type 218 SIU is programmed by assembly mounted address jumpers and that no other setup is required Diagnostics Ensure the Type 218 SIU supplied has a complete set of internal diagnostics self tests run continuously to monitor critical components of the unit Provide unit with a front panel LED indicator that can be used to report the current Input Output assembly address assignment of the unit for cabinet configuration verification Ensure unite has a diagnostic EIA 232 port on the front panel to interface with the SIU 218 functions 14 Model 242 DC Isolator Provide Model 242 DC Isolators that are in accordance with the latest version of CALTRANS Specifications as referenced earlier in this section Provide isolators that e Allow 242 isolator input signal polarity to easily be inverted without the use of tools Acceptable methods are removable jumpers or dip switches Unacceptable methods are soldering or desoldering a diode or resistor e Output is OFF for input voltages greater than 12 volts e Output is ON for voltages of less than 8 volts that have a duration of at least 5 to 25 ms optional 2 7 ms e Minimum output pulse width is 100 ms with a valid input can be disabled e Output is optically isolated open collector NPN transistor e Capable of sinking 50 ma when on e Can register a new input within 25 ms of the old signal going away and e Output clamped on power up a
81. ials Warranties 925 2 31 Steel Strain Poles A B C D Requirements Ensure that steel strain poles conform to Section 639 and include hardware for span wire attachments anchor base and anchor bolts for the purpose of supporting span wire suspended signs and or signals For signal supports ensure that the opening at the top and bottom of the pole is large enough to allow all wiring into and out of pole Do not strap conduit to strain pole because of insufficient opening allowances Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 72 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 925 2 32 Pre Stressed Concrete Strain Pole A Requirements Ensure that Pre stressed concrete strain poles for overhead signs and signal supports conform to Section 500 For signal supports ensure that the opening at the top and bottom of the pole is large enough to allow all wiring into and out of pole Do not strap conduit to strain pole because of insufficient opening allowances Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 33 Traffic Signal Pull Box A Requirements Ensure that traffic signal pull bo
82. icator remains extinguished if the monitor has not been triggered by a 24VDC fault WDT ERROR Ensure the WDT ERROR indicator illuminates when a controller Watchdog fault is detected Ensure the WDT Error indicator flashes ON once every 2 seconds if the WD Enable switch on the monitor is placed in the OFF position to disable Watchdog monitoring or the AC Line voltage is below the Watchdog disable level CONFLICT Ensure that the CONFLICT indicator illuminates when a conflicting signal fault is detected DIAGNOSTIC Ensure the DIAGNOSTIC indicator illuminates when one of the following faults is detected Internal Watchdog fault Memory Test fault or internal power supply fault This indicator is intended to inform the service technician of a monitor hardware or firmware failure RED FAIL Ensure the RED FAIL indicator illuminates when an absence of signal is detected on a channel s Ensure the RED FAIL indicator flashes ON once every two seconds if the RED ENABLE input is not active or a Special Function input is active or the EE input is active 17 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment b c vii viii ix Xi DUAL IND Ensure the Dual IND indicator illuminates when a GY Dual or GYR Dual Indication fault is detected on a channel s CLEARANCE Ensure the Sequence indicator illuminates when the minimum Yellow Clearance time has not been met on a channel s P
83. ice panel The jack shall intermate with a three circuit 1 4 inch 6 35 mm diameter phone plug The tip and ring middle circuits of the jack shall be connected to the logic ground and the interval advance inputs of controller unit When the manual hand cord is plugged into the jack and the pushbutton is pressed logic ground shall be connected to the interval advance input of the controller unit A Manual ON OFF Switch shall be provided on the police panel which grounds the Manual Control Enable C1 Pin 53 input to the controller whenever the switch is in the ON position and advance input C1 Pin 80 A manual pushbutton with cord shall be provided The cord shall have a minimum length of 6 feet 1 8M It shall have a 1 4 inch 6 35 mm diameter three circuit plug connected to one end and a manual pushbutton enclosed in a hand held enclosure at the other end A complete cycle push release of the manual pushbutton shall terminate the controller unit interval which is active except the vehicular yellow and all red clearance intervals Cycling the push button during the vehicular yellow or all red clearance intervals shall not terminate the timing of those intervals 22 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 21 22 23 24 25 26 Cabinet Model 332A with Auxiliary Output File Ensure that this unit meets the requirements of Subsection 925 2 04 A 20 above except that the cab
84. inet Interlock Do not install the interlock circuit as detailed in the CALTRANS Specifications 34 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 10 Cabinet Drawer Equip each Model 340 342 346 352 and 356 cabinet with an aluminum storage compartment mounted in the rack assembly with the approximate following dimensions 16 inches 400 mm wide 14 inches 350 mm long and 1 75 inches 44 mm deep Mount this compartment directly under the Type 2070 controller Provide a drawer with telescoping drawer guides to allow full extension from the rack assembly When extended the storage compartment opens to provide storage space for cabinet documentation and other miscellaneous items Ensure that the storage compartment be of adequate construction to support a weight of 25 pounds 12 kg when extended Provide a top for the storage compartment that has a non slip plastic laminate attached which covers a minimum of 90 of the surface area of the top Test Program Supply each cabinet with a diagnostic test program which verifies the operation of the cabinet Ensure that the program can test cabinet wiring related to the output file input file and police panel and flash switches In addition ensure that the program can check the operation of the SIU AMU and CMU by generating all possible conflicts in sequence Surge Protection Equip each cabinet with devices to protect the control equipment from s
85. inet is configured with an Auxiliary Output File Additionally the field wiring terminals may be mounted on the rear of the input file Cabinet Model 336S Base Mount This unit meets the CALTRANS Specification with the addition of approximately 6 additional inches 150 mm of cabinet height exclusive of the M base adapter Configure the internal component layout so that the additional space is available in the bottom area of the cabinet cage Ensure that the field wiring input panels and surge protection conform to Table 925 6 Model 336S Default Input File Assignment Detail and Table 925 7 Required Surge Arrestors for Model 336S Cabinet Ensure that the C1 connector harness is provided with pins for all 104 inputs and outputs from the controller A manual jack shall be installed on the police panel The jack shall intermate with a three circuit 1 4 inch 6 35 mm diameter phone plug The tip and ring middle circuits of the jack shall be connected to the logic ground and the interval advance inputs of controller unit When the manual hand cord is plugged into the jack and the pushbutton is pressed logic ground shall be connected to the interval advance input of the controller unit A Manual ON OFF Switch shall be provided on the police panel which grounds the Manual Control Enable C1 Pin 53 input to the controller whenever the switch is in the ON position A manual pushbutton with cord shall be provided The cord shall have a minimu
86. input terminal 10A e Equipment Line Out AC line second stage output terminal 10A e Equipment neutral out neutral terminal to protected equipment e GND Earth connection e Supply a protector that is epoxy encapsulated in a flame retardant material e Configure the Equipment Line Out to provide power to the Type 2070 and to the 24 V power supply 35 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment b Inductive Loop Detector Inputs Protect each inductive loop detector channel input by an external surge protection device that meets or exceeds the following requirements e Athree terminal device two 2 of which are connected across the signal inputs of the detector with the third connected to the chassis ground to protect against common mode damage e Instantly clamps differential mode surges induced voltage across the loop detector input terminals via a semiconductor array The array appears as a low capacitance to the detector e Clamps common mode surges induced voltage between the loop leads and ground via solid state clamping devices e Withstand 25 100A surge current occurrences of a 10 x 700 us waveform e Have the following clamp characteristics Maximum break over voltage 170 V Maximum on stage clamping voltage 3V Response Time 5 ns Off stage leakage current 10 LA Capacitance less than 220 pf e Ensure that the unit also meets the following minimum requirements P
87. installed Base Mount Cabinets Only 1 Aluminum Cover Plate for Cabinet Bottom Pole Mount Cabinets Only Model 337 Cabinet 3 Flash Transfer Relays 1 Model 204 Flasher 1 Manual push button assembly Model 334 Cabinet with Auxiliary Output File for Ramp Metering Operations 1 Auxiliary Equipment Shelf 1 Output PDA Type 3 with Model 206 24 Volt DC Power Supply with flash transfer relay 1 Model 208 Monitor Unit 1 Model 420 Auxiliary Output File 1 Load Switch Model 200 1 4 Position Power Strip 1 Lower Input Field Termination Panel 7 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 1 Detector Test Switch Panel e Model CLAD Cabinet Lower input field termination panel 3 Model 242 DC Isolators in Slots 12 13 and 14 of Upper Input File 4 Flash Transfer Relays 2 Model 204 Flashers 1 Manual push button assembly 1 Auxiliary Output File Note Include above components in cabinet at time of delivery Other auxiliary cabinet components such as controllers monitors load switches etc will be ordered as separate items 2 Finish Use cabinets that have a bare aluminum finish see Subsection 925 2 07 A 1 for controller cabinet minimum fabrication Specifications 3 Locks Equip the main cabinet door with locks that accept No 2 Corbin keys Provide two sets of keys with each cabinet One set of keys is defined as one No 2 key and one police panel key 4 P
88. inum alloy 380 or extruded AII die cast parts shall be cleaned in an alkaline cleaning compound Extruded parts shall have an alodine conversion coating to provide proper base for paint adhesion The assembly is to be painted black and baked in an oven Ensure the assembly is provided with all required hardware All other hardware shall be stainless steel Fabrication General Provisions 101 through 150 Acceptance Ensure that this item consists hardware or as shown in the Standard Details This item will be approved upon submittal of catalog cuts Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 69 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 925 2 25 Balance Adjuster A Requirements Ensure this item consists of hardware that is cast from 316 Stainless Steel or 65 45 12 Ductile Iron or equivalent Ensure castings are free of voids pits dents molding sand and excessive grinding marks Exterior surface shall be cosmetically acceptable and free of molding fins cracks and other exterior blemishes All hardware shall be supplied and be stainless steel or galvanized Fabrication General Provisions 101 through 150 Acceptance Ensure this item consists of hardware as shown in the Standard Details This item will be approved upon submittal of catalog cuts Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 226
89. ium nitride technology Supply LED Arrow Signal Modules that fit in standard incandescent vehicle traffic signal housings and meet the TTE Vehicle Traffic Control Signal Heads Part 3 Light Emitting Diode LED Vehicle Arrow Traffic Signal Modules Use Table 925 20 for all references to minimum maintained Intensity values Ensure the LED arrow modules meet the required luminous intensity as shown in Table 925 20 Table 925 20 Minimum Maintained Luminous Intensity Values for Arrow LED Indications Candela Angle Candela 12 inch 300 mm 12 inch 300 mm Yellow Red Yellow Green 61 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Table 925 20 Minimum Maintained Luminous Intensity Values for Arrow LED Indications Candela Ange Candea 12 inch 300 mm 12 inch 300 mm Yellow Red Yellow Green 6 Pedestrian Signal Modules Supply LED Pedestrian Traffic Signal Modules that fit in standard pedestrian one section signal head manufactured in accordance with the ITE Pedestrian Traffic Control Signal Indications PTCSI housings and meet the ITE Pedestrian Traffic Signal Modules specification Ensure that the Pedestrian Indications for the Hand Man and Countdown are filled in so as to provide a solid uniform appearance Do not supply Pedestrian Indications for the Hand and Man that are outlines or pixelated Ensure
90. ks that accept No 2 Corbin keys Provide two sets of keys with each cabinet One set of keys is defined as one No 2 key and one police panel key 4 Power Equip the cabinet assemblies with an ITS power distribution assembly to generate AC and DC power for the electronic components except the DC power for the controller units 5 Mounting Equip the cabinets for pole or base mounting as specified in the Plans a Base Mount Supply Model 346 and 356 cabinets when specified as base mount with an M base mounting adapter installed b Pole Mount Supply Model 346 and 356 cabinets when specified as pole mount with two exterior pole mounting brackets that allow for mounting on steel concrete and timber poles Ensure that the bracket mounting holes are properly reinforced with metal plates of adequate size and strength welded longitudinally across the inside depth of the cabinet Ensure that the exterior mounting bracket is shipped installed on the cabinet housing Additionally provide an aluminum plate which covers the bottom cabinet opening 6 Cabinet Light Include in each cabinet one fluorescent strip lighting fixture mounted inside the top front portion of the cabinet Do not use a screw in type fluorescent lamp The fixture includes a cool white lamp covered and operated by a normal power factor UL listed ballast Install a door actuated switch to turn on the cabinet light when either door is opened 7 Cab
91. l System using the current licensed GDOT Central System Software for reporting configuring and logging Personal Computer Communications Have the manufacturer provide software to access the Signal Monitor status and event logs described in Subsection 925 2 04 A 15 d Ensure this software operates with current version of Microsoft Windows or Windows XP f Hardware 1 Red Monitoring a Red Field Inputs Ensure that the Signal Monitor is capable of monitoring sixteen Red field signals Ensure that a Red input is sensed active when the input voltage exceeds 70 Vrms Ensure that a Red input is sensed not active when the input voltage is less than 50 Vrms A Red input may or may not be sensed active when the input voltage is between 50 Vrms and 70 Vrms b Red Enable Input Ensure that the Red Enable input provides an AC input to the unit which enables Red Monitoring Dual Indication Monitoring and Sequence monitoring when the input is sensed active Ensure that the Red Enable input is sensed active when the input voltage exceeds 70 Vrms Ensure that the Red Enable input is sensed not active when the input voltage is less than 50 Vrms The Red Enable input may or may not be sensed active when the input voltage is between 50 Vrms and 70 Vrms c Special Function Preemption Inputs Ensure that the Special Function Preemption inputs 1 and 2 provide an AC input to the unit which disables only Red Fail Monitoring Lack of Output wh
92. l proof Provide the unit with a 0 5 inch 13 mm threaded opening with plug Ensure that the assembly is weatherproof and so constructed that when properly installed it will be impossible to receive an electrical shock under any weather condition Ensure that Pedestrian Pushbuttons are integrated with a sign as shown in the standard details Provide the sign size as indicated on the Plans GDOT will allow an adapter of cast aluminum GDOT will allow one of three options 1 The use of a 9 inch 229 mm by 15 inch 381 mm cast aluminum plate adapter to upgrade existing push button station 9 inch 229 mm by 12 inch 305 mm 66 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment B C 2 Push button station assembly 9 inch 229 mm by 15 inch 381 mm sign w round pushbutton adapter 3 The use of a 9 inch 229 mm by 15 inch 381 mm cast aluminum plate adapter to upgrade existing push button station 5 inch 127 mm by 7 inch 178 mm Ensure that the Pedestrian Push Button sign adapter plate is die cast aluminum and separate such that it is interchangeable Ensure that the Pedestrian Push Button sign adapter assembly be die cast aluminum and attached prior to shipping The plate shall be finished with black baked enamel paint unless otherwise specified by the Engineer Ensure the button assembly is configured to be a mechanical switch with ball and 2 inch mushroom plunger Ensure the
93. lacement of the of the UPS without shutting down the traffic control system Connectors to the UPS shall be circular and equipped with a safety interlock feature The UPS shall be capable of starting when no Utility AC is available m The UPS shall be compatable with the existing cabinet operation such that Flash Transfer Relays Flashers and police panel switches shall provide their normal operation n The UPS shall deliver 120 V ac out or 3 with an AC input between 85 and 135 VAC without discharging the batteries while operating in the true Online Mode The UPS shall support a generator input without using the batteries p The UPS shall have maximum dimensions of 19 inches in width 13 inches in depth and height of 6 inches The unit shall have a maximum weight of 30 pounds q Theunit shall provide the following electircal characteriestics 1 Input a Nominal Voltage 120 VAC single phase b Voltage Range 85 to 135 VAC without using batteries c Frequency 50 to 60 Hz or 5 d Maximum current draw 16 5 amps power factor corrected e Protection Fuse 20 Amps 2 Output a Nominal voltage 120 VAC Single Phase b Power Rating Minimum 1250 VA 875 Watts Maximum 2000 VA 1400 W c Voltage Regulation or 2 for 100 step load change and from high battery to low battery condition d Frequency 50 or 60 Hz or 5 e Configuration keyed circular connectors and duplex recptacle f Wave Form True Si
94. le is identified for warranty purposes 925 2 16 LED Pedestrian Countdown Signal Module A Requirements This specification covers LED traffic signal module designed as a retrofit replacement for the message bearing surface of nominal 16 x 18 traffic signal housing built to the PTSCI Standard The message bearing surface of the module consists of an overlapping Hand and Man Symbols with a numerical display of numbers from 00 to 99 1 General Requirements Ensure that the unit supplied meets the applicable portions of section 925 2 15 of this specification Ensure that the message numbers 00 to 99 are a minimum of 9 inches in height 62 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Ensure the module fits in the Pedestrian Signal Housing without modification to the housing and requires no special tools for installation Supply LED signal modules that are watertight when mounted in the traffic signal housing Supply life data from the LED Signal Module manufacturer to calculate the expected useful life Supply modules with permanent markings for date of manufacture and date of installation 2 Optical Provide test data from an independent laboratory to verify that the performance of the product meets current ITE requirements Ensure that the individual LEDs are wired such that a catastrophic failure of one LED will result in the loss of not more than 546 of the sign
95. le maintaining a common vertical axis through couplers and mounting Ensure that terminal connections permit external adjustment about the mounting axis in 5 degree increments b Ensure that the signal is mountable with ordinary tools and capable of being serviced with no tools Supply attachments such as back plates or adapters that conform and readily fasten to existing mounting surfaces without affecting water and light integrity of the signal Supply heads with tri studs for mounting 3 Electrical Supply lamp fixtures that comprise a separately accessible housing and integral lamp support indexed ceramic socket and self aligning quick release lamp retainer Ensure that electrical connection between case and lamp housing can be accomplished with an interlock assembly which disconnects lamp holder when opened Include a covered terminal block for clip or screw attachment of lead wires for each signal section Use concealed No 18 AWG stranded and coded wires to interconnect all sections to permit field connection within any section 4 Photo Controls Ensure that each signal includes integral means for regulating its intensity between limits as a function of the individual background illumination Ensure that lamp intensity is not less than 97 of uncontrolled intensity at 10 750 lux and reduces to 15 2 of maximum at less than 10 75 lux Ensure that response is proportional and essentially instantaneous to any detectable increas
96. le to detect the presence of active voltage on the green and yellow green and red or yellow and red field signal inputs of a channel GYR Dual Indication fault DUAL IND shall be a latching fault Ensure this function is enabled on a per channel basis using dip switches mounted on the PCB labeled CHI through CH16 Ensure that the GYR Dual Indication monitoring function is enabled for all selected channels except when the Red Enable input is not active or pin EE is active a GY Dual Indication Monitoring Ensure that the Signal Monitor is able to detect the presence of active voltage on the green and yellow field signal inputs of a channel GY Dual Indication fault DUAL IND shall be a latching fault Enable this function with a dip switch on the PCB labeled GY ENABLE When the switch is in the ON position monitor all channels for simultaneous active green and yellow inputs on a channel When selected by the GY ENABLE switch ensure that the GY Dual Indication monitoring function is disabled when pin EE is active b Dual Indication Recognition Time Ensure that the Signal Monitor triggers when multiple inputs are active on a channel for more than 500 ms Ensure that the Signal Monitor does not trigger when multiple inputs are active on a channel for less than 250 ms Channels with multiple voltages active for more than 250 ms and less than 500 ms may or may not trigger the unit Clearance Short or Absent Yellow Monitoring Ensure that
97. lear face with or without legend which can accept a silk screened legend on the first surface Provide a thickness of at least 0 31 inches 8 mm 6 Legend Acceptable legends are as follows Text e NO LEFT TURN e NO RIGHT TURN e SIGNAL AHEAD e NO TURNS Symbols e NO LEFT TURN SYMBOL 64 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment e NO RIGHT TURN SYMBOL B Fabrication General Provisions 101 through 150 C Acceptance General Provisions 101 through 150 D Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 18 Lane Use Control Signal A Requirements Ensure that all signals are LED and conform to current ITE Standards Supply all signals with the necessary mounting hardware to provide for mounting as shown on the Plans Provide mounting for one way or two way configurations l General Requirements a Weight Ensure that one way units weigh not more than 50 pounds 23 kg and two way units weigh not more than 60 pounds 27 kg regardless of messages Color Ensure that the color of lane use control signal indications is clearly visible for 0 25 mile 0 38 km at all times under normal atmospheric conditions Provide lane use control signals with a visibility angle of a minimum of 60 degrees Housing Ensure that the housing of each signal is polycarbonate or a one piece corrosion resistant aluminum alloy die casting or equ
98. lies such that the block power supply does not block other outlets Attach power strip to a permanent location that is easily accessible to devices in the rear of the cabinet Provide hard wire connection to the Cabinet AC power controlled by a 15 amp GFI breaker Do not use plug in power strips Surge Protection Equip each cabinet with devices to protect the control equipment from surges and over voltages Design the surge protector panels to allow for adequate space for a wire connection and surge protector replacement without the removal of terminal blocks or panels Provide surge protectors for the input sections as detailed below and as shown in the Input Terminal and Surge Arrestor Detail Supply surge protectors that meet the following Specifications a AC Service Input Include a surge protection unit for each cabinet on the AC service input that meets or exceeds the following requirements e Provide a hybrid type power line surge protection device on a separate service panel that is external to the PDA Install the protector between the applied line voltage and earth ground Use a surge protector capable of reducing the effect of lightning transient voltages applied to the AC line that conforms to the following Peak surge current for an 8 x 20 us waveform 20 000A for 20 occurrences Clamp voltage 20 000A 280V max Maximum continuous operating current 120V 60 Hz 10A Series Inductance AC Line AC Neutral 200 micro henries Re
99. ll Sub Assembly a Photocell 1 Mechanical a The case shall be constructed of Lexan and shall be UV stabilized to screen out ultraviolet rays b The sensor head shall have a swivel base which can swing through 180 c The sensor shall be mounted in a 1 2 inch knock out or in a 7 8 inch opening with a gasket 2 Hlectrical a The operational voltage 120 Vac b Sensor shall use a cadmium sulphide light sensing element c The output contacts shall be normally closed on between dusk and dawn d The normal failure mode is to fail in the closed on position e The control wiring shall be 2C 16 AWG f The control wiring color code is Power in Line Black 82 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 3 Common Neutral White Output Red Environmental a Operate over temperatures of 40 to 140 F 40 to 60 C b Water tight b Junction Box 1 2 3 Mechanical a The junction box size shall be nominally 6 X6 X4 15 cm X 15 cm X 10 1 cm b The junction box shall have a NEMA 3R rating c The junction box shall be constructed of 16 carbon steel d The junction box shall have a drip shield top and smooth seamless front and sides e There shall be a strain relief clamp sized for 7C 14 AWG cable in the junction box f Drill as indicated in detail Electrical a The terminal block inside the junction box shall
100. ly replaced and commercially available Batteries used for UPS shall consist of a minimum of 6 batteries with a cumulative minimum rated capacity of 240 amp hours Batteries shall be deep cycle sealed prismatic lead calcium based AGM SVRLA Absorbed Glass Mat Valve Regulated Lead Acid Batteries shall provide a connection system that shields the terminals from exposure and accidental shorting Batteries shall be certified by the manufacturer to operate over a temperature range of 40 C to 74 C The batteries shall be provided with appropriate interconnect wiring and corrosion resistant mounting trays and or brackets appropriate for the cabinet into which they will be installed 46 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment g Batteries shall indicate maximum recharge data and recharging cycles Batteries shall include labels identifying the date of manufacture Do not use any battery with manufacture date older than 6 months before the cabinet installation h Battery Harness 1 Battery interconnect wiring shall be via two part modular harness The cables shall be protected with abrasion resistant nylon sheathing The interconnect cables shall connect to the base module via a quick release connector The connector shall have interlocking pins to prevent turn on if batteries are not connected and shut off the UP S should the batteries be disconnected 2 All battery interconnect har
101. m length of 3 feet 0 9 m It shall have a 1 4 inch 6 35 mm diameter three circuit plug connected to one end and a manual pushbutton enclosed in a hand held enclosure at the other end A complete cycle push release of the manual pushbutton shall terminate the controller unit interval which is active except the vehicular yellow and all red clearance intervals Cycling the push button during the vehicular yellow or all red clearance intervals shall not terminate the timing of those intervals Cabinet Model 3368 Pole Mount Ensure that this unit meets the requirements of Subsection 925 2 04 A 22 above except that the cabinet is configured for pole mounting as specified in the General Requirements for Type 170 Cabinet Assemblies Cabinet Model 336S Base Mount with Auxiliary Output File Ensure that this unit meets the requirements of Subsection 925 2 04 A 22 above except that the cabinet is configured with an Auxiliary Output File Additionally the field wiring terminals may be mounted on the rear of the input file Cabinet Model 337 The Model 337 cabinet is a compact cabinet with an output capacity of four vehicle phases plus two pedestrian phases the dimensions not to exceed 17 inches 425 mm deep x 20 inches 500 mm wide x 35 inches 875 mm high and its shipping weight not to exceed 175 pounds 80 kg Supply the cabinet assembly with capacity for 11 two channel slots in the input file Ensure that the pin assignments of the
102. ment Pn Function Pin L 5 seesarFuneiongz 16 Channel Red s ou i8 wo 9 Kouto i9 Ewo A jumper option shall be provided to allow the connection of Pin 4 to be made with Chassis Ground 2 Front Panel Ensure the front panel is constructed of sheet aluminum with a minimum thickness of 0 090 in 2 286 mm and finished with an anodized coating Ensure the model information shall be permanently displayed on the front surface a Indicators Ensure that all display indicators are mounted on the front panel of the Signal Monitor and are water clear T 1 package Super Bright type LEDs Ensure that all fault LEDs are red except the AC POWER indicator which is green Provide a separate Red Yellow and Green indicator for each channel Label the indicators and provide the information as follows i iii Vi AC POWER Ensure the AC Power indicator flashes at a rate of 2 Hz when the unit has detected a low voltage condition as described in Subsection 925 2 04 A 15 b 10 a Ensure the AC POWER indicator flashes at a rate of 4 Hz during the minimum flash interval as described in Subsection 925 2 04 A 15 b 10 b Ensure that the indicator illuminates when the AC Line voltage level is restored above the brownout level Ensure the indicator extinguishes when the AC Line voltage is less than 80 Vac VDC FAILED Ensure the VDC FAILED indicator illuminates when a 24VDC fault condition is detected This ind
103. monitor unit shall sense the Cabinet 24 VDC Power Supply Output Voltage Voltages sensed at 18 VDC or below for a duration of 500 ms or longer shall cause a FAILDED state Voltages sensed at 22 VDC or above shall NOT cause a FAILED state Voltages sensed below 22 VDC for a duration of 200 ms or less shall NOT cause a FAILED state All timing and voltages conditions other than those specified above may or may not cause a FAILED state A FAILED state caused by sensing the power supply shall illuminate a front panel indicator light labeled VDC FAILED The indicator shall remain ON until Unit Reset Only Unit Reset shall reset the power supply sense circuitry from a FAILED state d FAILED State Output Circuits 1 2 An electro mechanical relay shall be provided to switch an output circuit during a FAILED state The relay coil shall be energized in a NON FAILED State The relay contacts shall be rated for a minimum of 3 amperes at 120 VAC and 100 000 operations Contact opening closing time shall be 30 ms or less e Monitor Unit Reset 1 2 3 A momentary SPST CONTROL switch labeled RESET shall be provided on the unit front panel to reset the monitor unit circuitry to a NON FAILED state The switch shall be so positioned on the front panel that the switch can be operated while gripping the front panel handle The unit shall be provided with provision to drive an external NE H light through a 56K Ohm Watt Seri
104. n oo s Co 0 to a R C1 Pin O 3 D 2 5 o lt 1 oi w EN E BN I N OT A 5 2 ol m lt gt m lt w JI i ID Bo B Oo wW co m co eo Oo o zi to ITI lt O lt U a Z z ao ZIP 5 m lt N au UJ gt 2 E gt no Field Term Channel C1 Pin 5 44 2 Field Term 3 4 Ph5 Ph6 Mali TB 3 TB 3 a 5 TB5 TB 7 Ta 7 TB 7 11 12 13 4 7 8 11 12 7 8 Table 925 5 Required Surge Arrestors for Model 337 Cabinet Field Terminal Block Required Arrestor TB 8 Section 925 2 04 A 13 f TB 9 Section 925 2 04 A 13 f TB 9 e Terminal Block only Section 925 2 04 A 13 f TB 2 TB 3 TB 4 TB 5 TB 6 TB 7 Section 925 2 04 A 13 c os CI co w ce 0 a ua m 3 30 of 84 Office of Traffic Safety 8 Design Section 925CL Traffic Signal Equipment Table 925 6 Model 336S Default Input File Assignment Detail i a ee D DIS OE CA ORO pa Be Re Det DRE DSt De Deu DSt Bet DE TBA GBA DE De Pe 56 39 58 41 55 40 57 42 51 71 72 67 68 81 Phi Ph2 Ph3 Ph4 Ph5 Ph8 SE1 EVA EVB Ph2 Ph6 FLASH PED PED Is TB 7 TB 7 TB 8 TB 8 TB 8 rs iia lan Es TB 5 la PT 2 56 19 10 9 10 Ph2 Ph4 h4 Ph6 Ph6 Ph8 Ph8 R R EVC EVD Ph4 Ph8 STOP CALL CALL CALL PED PED TIME ad B 7 TB 8 TB 8 TB 8 TB 9 Men Sa e TB 5 A a NC 1 12 1 12 3 4 11 12 Table 925 7 Required Surge Arrestors for Model 336S
105. n 925CL Traffic Signal Equipment 7 8 9 a AC Line Brownout Recognition Ensure that the Signal Monitor is able to detect that the AC Line has fallen below 98 or 2 Vac for greater than 400 or 50 ms This shall force the output Relay to the de energized fault state enable the Stop Time output and cause the AC POWER LED to flash at a 2 Hz rate Ensure that the unit maintains this state until the AC Line voltage rises above 103 or 2 Vac for greater than 400 50 ms Provide a jumper option which will change the AC Brownout dropout level to 92 or 2 Vac and the restore level to 98 or 2 Vac b AC Line Power up and Brownout Delay Time When the AC Line is greater than 103 or 2 volts after power up or Brownout restore ensure that the Signal Monitor holds the Output Relay in the de energized fault state and enable the Stop Time output for a period of not less than 6 0 or 0 5 seconds and not greater than 10 0 or 0 5 seconds Ensure that this flash interval is terminated after at least 6 0 or 0 5 seconds if the Signal Monitor has detected at least five transitions of the Watchdog input If the Signal Monitor does not detect five transitions of the Watchdog input before 10 0 or 0 5 seconds ensure that the Signal Monitor goes to the fault state During this interval ensure that the AC POWER LED flashes at a 4 Hz rate Red Fail Monitoring Ensure that the Signal Monitor is able to detect the abs
106. n in Figures 925 2 925 2A and 925 2B b Provide all Cabinet Model 332A equipment materials and functions as required in 925 2 04 except as modified herein and include all accommodations for the equipment and accessories as described in these Specifications and the Plans as shown in Figures 925 2 925 2A and 925 2B c Provide door open switches on four doors and configure the switches so that any single door opening will provide an input to the controller through the C115 I O connector d Provide only one set of controller shelves for the 2070L controller e Do not configure the cabinet for dial up communications and do not provide an RJ11 jack Terminal Block TBO or Buchanan block Do not provide a voice ST jack or circuit Do not provide 170 local communications or field master communications harnesses f Provide two cabinet ventilation fans with a minimum capacity of 200 cubic feet of free air delivery per minute The fan thermostat shall be set at its lowest limit or 70 degrees F which ever is greater g Provide each of the four cabinet doors with an intake and filter as specified in Subsection 6 2 7 1 of the AASHTO ITE NEMA ITS Cabinet Standard specification Auxiliary Output File Ensure all wiring is labeled color coded with signal cabinet wiring diagram AC white Ground green AC black 24 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment E es Field Switch
107. n substantiating documentation must be supplied from an independent test laboratory to show the product has passed design qualification testing in accordance with section 6 4 of the ITE Vehicle Traffic Control Signal Heads LED Circular Signal Supplement Testing for Yellow indications may be made immediately after the modules are 60 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment energized Ensure the report includes a Minimum Maintained Luminous Intensity chart for the module being provided that uses the same horizontal and vertical angles as shown in Table 925 20 Ensure all modules are provided with a signed copy of the production and test and inspection as detailed in section 6 3 of the ITE Vehicle Traffic Control Signal Heads LED Vehicle Arrow Traffic Signal Supplement Supply lenses for that are made of ultraviolet stabilized polycarbonate Ensure that the external lens surface is smooth with no raised features to minimize the collection of dirt diesel smoke and other particulate contaminates and to facilitate periodic cleaning Supply Red and Yellow LEDs that utilize AllnGap technology either AS Absorbing Substrate or TS Transparent Substrate and do not exhibit degradation of more than 30 of their initial light intensity following accelerated life testing operating at 185 F 85 C and 8596 humidity for 1000 hours AlGaAs technology is not acceptable Supply Green LEDs that utilize gall
108. nal Heads A Requirements Supply vehicle signal heads that are 12 inches 300 mm in diameter for traffic signal control applications For ramp metering systems supply both 12 inches 300 mm and 8 inches 200 mm as per the Plans Ensure that the 8 inch 200mm or 12 inch 300 mm polycarbonate vehicle signal heads meet the current ITE specification on Vehicle Traffic Control Signal Heads with the following modifications and or clarifications 1 Unless otherwise approved by the Engineer or as noted on the Plans supply signal heads with the following exterior color scheme e Signal Housing Gloss Black e Front Face including Doors and Visors Gloss Black 2 Provide housing and housing door that are one piece injection molded ultraviolet and heat stabliized polycarbonate resin with the color impregnated in the material 3 Terminate the wiring from each signal section in the top section of the head assembly Ensure that the cable jacket is a minimum of 6 inches inside the signal head assembly Provide the appropriate Vehicle Signal LED Signal in each section either Circular or Arrow Module 5 Provide an effective seal with the LED module to make the assembly weather tight Mount one aluminum reinforcing support plate in the top of the red section of each three four or five section signal head for the installation of mounting hardware 7 Install a support plate between each section of all signal heads Place these plates such that
109. nal may be tapered Fabricate pole caps when required of cast material and secure in place with set screws Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 70 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment D Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 28 Pedestal Pole Base A Requirements Supply a base that is octagonal in shape and ensure that all design radii are smooth and intact Ensure that the exterior surface finish is smooth and cosmetically acceptable by being free of molding fins cracks and other exterior blemishes Fabricate from new aluminum ingot Do not use scrap materials Minimum requirements are as follows e ALUMINUM ALLOY NO 319 ELONGATION IN 2 IN 50 mm 2 5 e TENSILE STRENGTH KSI MPa 34 234 BRINELL HARDNESS 85 e YEILD STRENGTH KSI MPa 19 131 SHEAR STRENGTH KSI MPa 232 1600 1 Ensure this item consists of octagonal cast aluminum with bare finish and has a minimum weight of 21 pounds 9 5 kg Thread the upper end to receive a 4 inch 100 mm National Pipe Thread NPT pipe shaft 2 Design the base so that it may be fastened to a foundation with four 4 0 75 inch 19 mm anchor bolts located 90 degrees apart on the bottom of the base Provide slots in the bottom of the base 1 5 inch 38 mm wide and 2 5 inches 63 mm long measured along the circumfere
110. nce of the bolt circle allowing a proper fit even if the bolts are placed slightly off center 3 Design the base to accommodate bolt circles of a minimum of 12 inches 300 mm through a maximum of 14 5 inches 363 mm and anchor bolts with a minimum of 0 63 inches 16 mm through 1 inch 25 mm diameter 4 Ensure that the base meets or exceeds current AASHTO breakaway requirements Provide test reports from an FHWA approved independent laboratory certifying that the base has been tested and meets all applicable requirements In addition supply a statement of certification from the FHWA stating such tests have been accepted and approved 5 In order to prove structural soundness provide a certification from a recognized independent structural laboratory certifying that the base will withstand a bending moment of 10 750 ft Ibs 14 575 N m 6 Supply the base with a set of four 4 anchor bolts 0 75 inch 19 mm diameter by 18 inches 450 mm in length material per ASTM A 572A 572M Galvanized per ASTM A 153 A 153M Supply 1 hex nut and 1 flat washer with each bolt B Fabrication General Provisions 101 through 150 C Acceptance General Provisions 101 through 150 D Materials Warranty General Provisions 101 through 150 925 2 29 Pedestal Pole Foundation Anchor Asembly A Requirements Provide cast in place concrete foundation B Fabrication General Provisions 101 through 150 C Acceptance General Provisions 101 through 150
111. nd are not frosted have a surface coating to provide front surface abrasion resistance Ensure the Red and Yellow section module lens are tinted to correspond with the wavelength chromaticity of the LED Ensure Green Section modules are clear Ensure the modules allow a reduction of the intensity of the light output in response to an input from the traffic signal controller Ensure the minimum light output when dimmed is not less than 3096 of the minimum maintained luminous intensity as defined in the applicable Signal Head Module 4 Circular Signal Modules Supply LED Circular Signal Modules that fit in standard incandescent vehicle traffic signal housings and meet the Performance Specification of the ITE Vehicle Traffic Control Signal Heads LED Circular Signal Supplement In case of conflict this specification shall govern Before delivery of any modules supply certification that module is to be in compliance with these specifications In addition substantiating documentation must be supplied from an independent test laboratory to show the product has passed design qualification testing in accordance with section 6 4 of the ITE Vehicle Traffic Control Signal Heads LED Circular Signal Supplement Testing for yellow LED Circular Indications shall be allowed immediately after the modules are energized Red Green and Yellow Circular indications shall meet the minimum luminous intensity values as shown in Table 925 19 for a minimum period of 60 months
112. nd down 38 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 15 20 21 Model 200 Switchpack Provide Model 200 Switchpacks that are in accordance with the latest version of CALTRANS Specifications as referenced earlier in this section Model 204 Flasher Unit Provide Model 204 Flasher Units that are in accordance with the latest version of CALTRANS Specifications as referenced earlier in this section Flash Transfer Relay Provide Flash Transfer Relays that are in accordance with the latest version of CALTRANS Specifications as referenced earlier in this section Cabinet Model 342 Provide Cabinet Model 342 that meets the CALTRANS Specification with the addition of surge protection as detailed in Table 925 13 Model 342 ITS Cabinet Default Input Files Assignment Detail Table 925 14Required Surge Arrestors for Model 342 ITS Cabinet and Table 925 15 Model 342 amp 346 ITS Cabinet Default Output File Assignment Detail Supply Model 342 with lower input panel cabinets with housing Type 1 and all components as described in these Specifications Supply cabinets having two input files which conform to the CALTRANS Specifications and configured to accept two 2070 controllers in the top portion of the cabinet Configure the cabinet for dial up communications Mount a two 2 circuit Buchanan connector on the right side panel from rear door Mount a phone jack with a RJ11
113. nector and terminal assembly designated as P20 for monitoring the absence of red as an integral part of the output file Terminate the connector and ensure compatible with the cable and C connector of a Type 2010 conflict monitor unit capable of monitoring the absence of red Provide the pin assignments of the P20 connector and terminal assemble with the cabinet Plans Ensure that the P20 connector is physically alike to the cable and connector of a Type 2010 conflict monitor unit to prevent the absence of red cable connector from being inserted into the P20 connector 180 degrees out of alignment Submit details for programming of the unused red channels for approval 8 Cabinet Light Include in each 332A and 3368 cabinet one fluorescent strip lighting fixture mounted inside the top front portion of the cabinet Include in each CLAD cabinet two fluorescent strip lighting fixtures one mounted inside each top front portion of the cabinet sides Do not use screw in type fluorescent lamp 8 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 12 13 The fixture includes a cool white lamp covered and operated by a normal power factor UL listed ballast Install a door actuated switch to turn on the cabinet light when either door is opened or either door of either side of a CL4D cabinet Cabinet Interlock Do not install the interlock circuit as detailed in the CALTRANS Specifications Cabinet
114. ness wiring shall be UL Style 1015 CSA TEW or Welding Style Cable or equivalent all of proper gauge with respect to design current and with sufficient strand count for flexibility and ease of handling 3 Battery construction shall include heavy duty inter cell connections for low impedance between cells and heavy duty plates to withstand shock and vibration B Fabrication C D Refer to Subsection 925 2 07 A 1 for controller cabinet minimum fabrication Specifications Acceptance General Provisions 101 through 150 Each UPS shall be manufactured in accordance with a manufacturer Quality Assurance QA program The QA program shall include two Quality Assurance procedures 1 Design QA and 2 Production QA The Production QA shall include statistically controlled routine tests to ensure minimum performance levels of UPS units built to meet this specification and a documented process of how problems are to be resolved The manufacturer or an independent testing lab hired by the manufacturer shall perform Design Qualification Testing on new UPS system s offered and when any major design change has been implemented on an existing design A major design change is defined as any modification either material electrical physical or theoretical that changes any performance characteristics of the system or results in a different circuit configuration Where a dispute arises in determining if a system is a new design or if the system has
115. net has four full size doors to allow complete access from the front or back of the cabinet Design the rack assembly to mount in CALTRANS standard rails to allow for a Model 204 flasher Provide a receptacle to accept the plug in power distribution assembly card guides and edge connectors for the input file card guides to support the conflict monitor and load switches and flash transfer relays Fabrication Refer to Subsection 925 2 07 A 1 for controller cabinet minimum fabrication Specifications Acceptance Refer to Subsection 925 2 02 A for compliance with CALTRANS QPL Materials Warranty Refer Subsection 925 2 01 D for Materials Warranties 39 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Table 925 13 Model 342 ITS Cabinet Default Input Files Assignment Detail Me etm 1 Tg T T41 T8 te IE 6 1 18 Lower Opto Inputs Lower File Slot 2 3 4 5 6 7 SIU Pin A6 A7 A8 A9 A10 A11 A15 SIU Byte Bit 3 2 3 4 3 6 4 0 4 2 5 2 SIU Input 9 11 13 15 17 19 23 25 27 29 2070 Input 0 28 8 22 6 43 51 32 12 38 2070 Port 1 1 4 5 2 1 3 7 1 7 6 4 7 4 5 1 2 5 5 7 Function Ph 2 Det Ph 2 Det Ph 2 Det Ph 3 Det Ph 4 Det Ph 4 Det Sp Det 5 Pd 2 Det Pre 1 Pre 5 Field Term TB 2 5 6 TB 29 10 TB 4 1 2 TB 4 5 6 TB 49 10 TB 6 1 2 TB 6 9 10 TB 8 4 6 TB 9 10 12 TB 9 5 6 SI
116. newarve g Overload capability 160 for 10 seconds h Effciency 85 at full load i Load power actor of 0 7 lagging to 0 7 leading 2 Mounting Configuration NOTE All references made to EIA rail or EIA 19 482 6mm rack shall conform to Electronic Industries Standards EIA 310 B Racks Panels and Associated Equipment with 10 32 Universal Spacing threaded holes a General 1 Inverter Charger Unit shall be rack mounted on a standard EIA 19 rack Supporting shelf shall be provided for mounting in cabinet Shelf shall be designed to support 50 Ibs 2 Power Transfer Relay and Manual Bypass Switch shall be mounted on EIA rail or approved location 3 All interconnect wiring shall be provided between Power Transfer Relay Bypass Switch and Cabinet Terminal Service Block and shall be no less than 3 meters 9 10 of UL Style 1015 CSA TEW with the following characteristics e AWG Rating 10 AWG e Stranding 105 strands of 30 AWG tinned copper e Rating 600 V 105 C PVC Insulation 44 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 4 Relay contact wiring provided for each set of NO NC relay contact closure terminals shall be 3 meters 10 feet of UL Style 1015 CSA TEW 18 AWG wire same ratings as above except 16 strands of 30 AWG tinned copper Connect the UPS BATTERY ON relay to the controller through the C11S I O connector 5 Figure 925 6 provides clarification as t
117. ng for multiple unit and 7 inches 175 mm long for single unit signals for each signal face Ensure that the visors are constructed of sheet aluminum or polycarbonate and encompass the top and sides of each section Painting 65 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Paint all signal surfaces inside and out with two coats of oven baked enamel in addition to the primer coat Paint the insides of the visors flat black The non illuminated portions of the signal face black or dark gray and all housings brackets and fittings highway yellow h Hardware and fittings Supply all necessary fittings pipe brackets hangers hubs etc for the type of mounting specified Ensure all fittings are aluminum or galvanized coated to prevent rust and corrosion i Sun phantom screen Provide each signal face with a screen which substantially counteracts sun phantom effect 2 Signal Display Ensure that the symbols which are on an opaque black or dark gray background meet ITE requirements and are blacked out when not illuminated 3 LED Optical System a Ensure that the LEDs supplied for the lane use control signal meet the Specifications for a type module as required in section 925 2 14 Ensure that each separate color indication in a sign face is illuminated by independent LEDs Ensure that the green arrow indication does not utilize the same termination points as any X indication
118. o be compatible with current GDOT Applications software 2070 7A Communications Module The 2070 7A Communications Module may be supplied as a separate item The 7A communications module is a dual async serial communications module Ensure the module supports serial communications on both ports Ensure it contains any configuration jumpers to be compatible with current GDOT Applications software 2070 8 Field I O Module The 2070 8 Field I O Module may be supplied as a separate item The 8 Field I O Module consists of the module chassis module power supply Field Control Unit Controller parallel input output ports serial communications circuits and module connectors Ensure the EXI connector is provided with appropriate mating connections to interface with either 6B or 7A communications modules Ensure the 2070 8 Field I O module is provided with the appropriate mating connector to mate with the C12S connector on the 2070 2B Field I O module Ensure the 2070 8 Field I O module functions as part of a Model 2070 LNI controller 2070 D Panel The 2070 D panel is supplied as a separate item The 2070 D panel supports the inputs and outputs of the D connector provided on a 2070 8 module which is also part of a Model 2070 LN1 Ensure the D Connector panel supports all 61 pins with a connecting MS D connector and terminal blocks Ensure the 2070 D Panel provides 6 of 84 Office of Traffic Safety amp Design Section 925CL Traffic
119. o how UPS Power Transfer Relay and Manual Bypass Switch are interconnected in the traffic control Cabinet Figure 925 6 UPS Utility Power Connection Diagram grn Inverter EGnd Power x Tronsfer se wht Relay Line In Line Out AC Line to AC Line from gt gt Transfer Relay Transfer Relay 332A Cab and Inverter and Inverter TBS AC EGnd AC Utility Line Power M IE algal Fag B red a uty ine over ET TE Bypass Switch AC Power To 332 Cab typicab AC EGnd Equip Gad Bus Bus bIk AC Line AC Neutral 332A CABINET Asa minimum these wires shall be provided in 3 meter lengths as part of the interconnect wiring kit 6 Provide auxliary receptacles in the cabinet for auxiliary equipment All receptacles shall be ULA98 WC596 specification grade duplex NEMA 5 15 receptacles mounted in metallic handy boxes with metal face plates positioned facing in to the cabinet interior as shown in Figures 925 2 and 925 2A Three 3 duples receptacles shall be UPS serviced with a dedicated breaker the receptacles and the breaker shall be labeled as UPS Service One 1 duplex receptacle shall not be UPS serviced and shall be labeled Non UPS 7 All necessary hardware for mounting shelf angles rack etc shall be included in the bid price of the UPS AII bolts fasteners and washers shall meet the following requirements e Screw type Pan Head Phillips machine screw e Size
120. or Assembly not shown No scale Figure 925 7 Typical Flashing Signal Cabinet Layout Cabinet Supply a NEMA Type 3R cabinet assembly manufactured of aluminum with a minimum thickness of 0 125 inches 3 mm Ensure that the cabinet exterior has a smooth uniform bare aluminum finish with all joints between adjoining cabinet components sides and bottom continuously welded on the outside to prevent the intrusion of moisture and dust Ensure that all welds are free of cracks blow holes and other irregularities Supply a cabinet with the following exterior dimensions Minimum Maximum Height 14 inches 350 mm 18 inches 450 mm Width 10 inches 250 mm 14 inches 350 mm Depth 7 inches 175 mm 10 inches 250 mm Use a cabinet door that is double flanged on all four sides to prevent the entry of dirt and liquids when the door is open Install a one piece gasket formed around the door opening to insure a weather tight seal when the door is secured Attach the door to the cabinet housing by a continuous tamper proof hinge Equip each cabinet with a Corbin 2 lock and one key Police panel type locks are not acceptable Install an aluminum back panel in the cabinet mounted on standoffs to facilitate mounting of internal components Install exterior aluminum mounting brackets which extend a minimum of 1 75 inches 44 mm and a maximum of 2 5 inches 63 mm from the top and bottom of the cabinet Use brackets that extend acro
121. ostic Display operation see Subsection 925 2 04 A 15 c Ethernet Communications Port i ii iii ly vi Use this port to provide communications via Ethernet This port shall be provided on the front panel The Ethernet port shall be electrically isolated from the MMU electronics and shall provide a minimum of 1500 Vrms isolation The connector shall be an RJ 45 eight pin connector Refer to Table 925 2 for Pin assignments The Signal Monitor shall have a communications port that provides the capability to send status and event to a Controller Unit or Personal Computer The manufacturer shall provide software to access the Signal Monitor status and event logs This software shall operate with Microsoft WindowsXPTM WindowsVistaTM Windows7TM and Windows8TM The communications software running on the PC shall be able to search the network and display a list of IP addresses and Monitor IDs of monitors responding on the network The communications software shall also be capable of making changes to the monitor network parameters such as IP address and subnet mask An HTML based capability shall be provided in the monitor to configure the network parameters of the MMU Ethernet port using a standard HTML browser The COMM indicator will illuminate for a period of 50 ms when a valid frame is received on the Ethernet port The COMM indicator will flash at a 4 Hz rate if the port is disabled due to the DTR signal in the false stat
122. ower Equip the cabinet assemblies with a power distribution assembly to generate AC and DC power for the electronic components except the DC power for the controller units Provide the Model 332 CL4D and 3368 cabinets with 3 DC isolators for Pedestrian Detector Inputs in slots 12 amp 13 and stop time flash sense in slot 14 of the input file 5 Mounting Equip the cabinets for pole or base mounting as specified in the Plans a Base Mount Supply Model 3368 cabinets when specified as base mount with a M base mounting adapter installed b Pole Mount Supply Model 3368 or 337 cabinets when specified as pole mount with two exterior pole mounting brackets that allow for mounting on steel concrete and timber poles Ensure that the bracket mounting holes are properly reinforced with metal plates of adequate size and strength welded longitudinally across the inside depth of the cabinet Ensure that the exterior mounting bracket is shipped installed on the cabinet housing Additionally provide an aluminum plate which covers the bottom cabinet opening 6 Unused Phase Monitoring Provide odd phase reds with ballast resistor 2K 10 watt dummy loads Do not wire the cabinet to monitor pedestrian yellow indications When auxiliary output file is used provide resistors for overlaps Neatly lace label and bundle the wiring from the signal monitor for pedestrian yellow monitoring on the back panel 7 Red Monitoring Provide a con
123. pounds Ensure that prefabricated controller cabinet bases are designed for a minimum lateral load of 1800 pounds over an 18 inch by 24 inch by 1 inch steel plate applied to the longest side and shall withstand a tested load of 2700 pounds The prefabricated controller cabinet base shall withstand a 50 foot pound impact administered with a 12 pound weight having a C tup without puncture or splitting in accordance with ASTM D2444 The prefabricated controller cabinet base shall meet the requirement of ASTM D543 Section 7 Procedure 1 Provide a copy of all test reports from a certified lab along with the materials certification package For CLAD cabinets provide a cabinet base with a cable entrance opening no less than 12 inches by 24 inches Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 35 Loop Lead In Cable A B C Requirements Ensure that loop detector lead in cable is No 18 AWG 3 pair shielded cable that meets IMSA specification 450 2 Ensure that identification markings are stamped on the jacket Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 74 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment D Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties
124. put 5 Configuration Change Log CF Ensure the Configuration Change log contains the following information a Program Card Matrix the permissive programming for each channel b Yellow Disable Jumpers the Yellow Disable programming for each channel c Dual Sequence Switches the switch programming for each channel d Option Switches RF 2010 RP Disable GY Enable SF1 Polarity Sequence Timing Minimum Flash Enable Configuration Fault Enable Red Cable Fault enable AC Brownout timing 15 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 6 eJ Watchdog Programming Watchdog Enable Watchdog Latch and Watchdog timing f Configuration CRC A unique CRC value which is based on the configuration of items a though e above Indicate on the log which items have been changed since the last log entry Signal Sequence Log Provide a log that graphically displays all field signal states for up to 30 seconds prior to the current fault trigger event Ensure that the resolution of the display is at least 50 milliseconds e Communications Functions 1 2 Controller Unit Communications Ensure that the Signal Monitor is compatible with the protocol of the current GDOT licensed firmware for 2070 controllers and Central System Control Ensure the 2010 Conflict Monitor supplied is able to communicate via a serial link to the 2070 Controller and then to a Centra
125. r maintaining agency all manufacturers warranties and guarantees for all signal equipment items listed in this document as well as any signal equipment listed in the Plans except for state or county supplied equipment Ensure that warranties and guarantees are consistent with those provided as customary trade practices or as otherwise specified in the Plans Standard Specifications Supplemental Specifications or Special Provisions Ensure and state that manufacturer s and supplier s warranties and guarantees are transferable to the agency or user that is responsible for traffic signal maintenance And said warranties and guarantees are continuous throughout their duration and state that they are subject to such transfer Ensure equipment provided under this specification shall be warranted by the manufacturer to be free from defects in materials and workmanship for a minimum period of two years from date of receipt or one year from date of acceptance of installation The exception is the other materials stated in this specification which have longer warranty durations Ensure the manufacturer will repair any faulty equipment during this period at no charge to the Department for parts labor or shipping to and from the factory 3 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 925 2 02 Type 2070 Controller Assemblies A Requirements For 2070 controller cabinet assemblies use 2070 controlle
126. r to Subsection 925 2 D for Materials Warranties 84 of 84 Office of Traffic Safety amp Design
127. r units that meet the requirements of the following or are previously approved by TSEF e Traffic Electrical Equipment Specifications TEES published by the State of California Business Transportation and Housing Agency Department of Transportation current edition and current addenda e CALTRANS Qualified Products List QPL e Ensure the unit supplied is compatible with current GDOT licensed firmware The following Specifications augment the CALTRANS Specifications and take precedence over conflicting CALTRANS Specifications 1 Input output I O and Configuration The 2070 Controller shall be supplied in one of the following configurations as specified in the Plans all modules are specified in TEES but these configurations supersede the defined configurations in TEES e 2070L Provide Chassis 2070 1B Single Board CPU 2070 2A Field I O Module 2070 3B Front Panel 8x40 display 2070 4B 3 5 amp Power Supply and a 2070 7A Module This unit is intended for interfacing in Type 170E or ITS cabinets and shall provide the default input and output configuration as shown in Tables 925 13 925 15 and 925 16 for ITS cabinets using a traffic signal application e 2070E Provide Chassis 2070 1E Single Board CPU 2070 2A Field I O Module 2070 3B Front Panel 8x40 display 2070 4B 3 5 amp Power Supply and a 2070 7A Module This unit is intended for interfacing in Type 170E or ITS cabinets and shall provide the default input and output config
128. raffic Safety amp Design Section 925CL Traffic Signal Equipment J Panel C UPS Electronics Module Video Encoder Battery Shelf 2 Battery Shelf 1 Service Entrance CCTV Interface Mounting Panel UPS serviced receptacles non UPS serviced receptacles J Panel D UPS Electronics Module Video Encoder CCTV Field Termination Mounting Panel Battery Shelf 2 Battery Shelf 1 Service Entrance UPS Bypass Figure 925 2B Typical CL4D J Panels C and D Configuration 28 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment B Fabrication Refer to Subsection 925 2 04 A 1 for controller cabinet minimum fabrication Specifications C Acceptance Refer to Subsection 925 2 01 A for compliance with CALTRANS QPL D Materials Warranty Refer Subsection 925 2 01 D for Materials Warranties 29 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment able 925 4 Model 332 Default Input Files Assignment Detail mE OE o fo 5 IO 3 2 e Ug o TT Oo Ba ga 9 UU ojo 33 Do U z 4A co Z 7 O O z D O m Bo Dp oo a oo e w 3 3 d di A D Oo U I EE eo N TB 2 TB 2 TB 4 TB 4 TB 4 Di TES TB 6 3 4 7 8 11 12 7 8 11 12 EE mi NE TBS ee TB 6 56 19 10 oz ejo F 3 sc 3 ao o
129. raffic Signal Equipment B C D 2 Hlasher Unit Supply a standard plug in two circuits NEMA flasher Ensure that the flasher is of all solid state construction meets the requirements of the NEMA Standards and is rated at a minimum of 10 A per circuit Ensure that the flasher utilizes zero voltage turn on and turn off current and be capable of dimming outputs 3 Time Switch Supply a time switch that meets the requirements of Subsection 925 2 09 of this specification 4 Surge Arrestor Supply flasher cabinets that incorporate an AC surge arrestor to protect the internal components from lighting and over voltages on the AC service input The requirements of the surge arrestor are as follows Peak Surge Current 20000 A Peak Surge Voltage 20KA 280 V Clamp Voltage 280 V amp 20kA Continuous AC Voltage 120 V AC RMS Response Time 5 nsec Operating Temp 40 F to 185 F 40 C to 85 C 5 Circuit Breaker Include a 15 Amp circuit breaker in each cabinet The circuit breaker shall have the following characteristics e Thermal Magnetic 1 pole 120 240 VAC at 50 60 Hz 15 A e Interrupting Rating of 10KA at 48 VDC e WireSize 14 to2 AWG e 35 MM Din Rail mounting 6 Terminal Block Include a four position terminal block in each cabinet for making field connections Properly label all field terminal connections 7 Construction Assemble the flasher assembly terminal block surge arrestor and circuit breaker in the cabinet as shown on
130. re range of 40 F to 165 F 40 C to 74 C Ensure that the power factor is 90 or greater at nominal rated voltage at 77 F 25 C after 60 minutes of operation Provide modules that do not exceed the maximum power consumption as shown in Table 925 18 Table 925 18 Maximum Power Consumption in Watts at 25 C 77 F amp 74 C 165 F Vehicle Indications Red Yellow Green Temperature 25C 74C 25C 74C 25C 74C 12 Inch 300 mm Circular 11 17 22 25 15 15 8 Inch 200 mm Circular 8 13 13 16 12 12 12 Inch 300 mm Arrow 9 12 10 12 11 11 Pedestrian Indications Hand Man Countdown Temperature 25C 74C 25C 74C 25C 74C 12 Inch 800 mm 11 12 10 12 8 12 Ensure that the total harmonic distortion THD is less than 20 at rated voltage at 77 F 25 C and that all LED traffic signal modules are in compliance with FCC noise regulations Ensure that the LED signal modules operate on line voltage 120 V AC nominal and are able to operate over the voltage range of 80 V AC to 135 V AC Power Supply must be integral to the module Provide transient voltage suppression rated at 1 500 W for 1 millisecond and fusing with a maximum rating of 2 A to minimize the effect and repair cost of an extreme over voltage situation or other failure mode 58 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Ensure the lens of the modules that are polymeric a
131. rrent e Differential mode e Common mode e Estimated occurrences e Response time e Input capacitance e Temperature 6 times 400 A 8 x 20 ms 1 000 A 8 x 20 ms 500 amp 200A 40 ns 35 pF typical 40 F to 4185 F 40 C to 85 C 10 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment e Mounting No 10 32 x 3 8 inch No 5 x 10 mm bolt e Clamp voltage e 2400 A diff Mode 30 V max e 21 000 A comm Mode 30 V max d Signal Load Switches Switchpacks Provide the output of all switchpacks in all output files and output PDAs with metal oxide varistors MOV tied from the AC positive field terminal to the chassis ground to protect switchpacks from surges on the AC output lines Ensure that these MOVs meet or exceed these requirements Steady state sinusoidal voltage RMS rating at 50 to 60 Hz of at least 150 V at 77 F 25 C Steady state applied DC voltage rating of at least 200 V at 77 F 25 C Transient energy rating is of at least 80 J for a single impulse of 10 1 000 us current waveform at 77 F 25 C Peak current rating of 6 500 A for a single impulse of 8 20 us waveform with the rated continuous voltage applied Varistor voltage of at least 212 V at 1 0mA of DC current applied for the duration of 20 us to 5s Clamping voltage of at least 395 V with an applied 8 20 us impulse of 100 A Typical capacitance at a frequency of 0 1 to 1 0 MHz of 1
132. rs ITE Vehicle Traffic Control Signal Heads Specification e ITE Vehicle Traffic Control Signal Heads Light Emitting Diode LED Circular Signal Supplement June 27 2005 Specification 1 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment e ITE Vehicle Traffic Control Signal Heads Part 3 Light Emitting Diode LED Vehicle Arrow Traffic Signal Modules Specification e ITE Pedestrian Traffic Control Signal indications Part 2 Light Emitting Diode LED Pedestrian Traffic Signal Modules Specification e International Municipal Signal Association IMSA 420 1 Specification e IMSA 320 4 Specification e IMSA 120 6 Specification e IMSA 50 2 Specification e IMSA 51 1 Specification e Underwriters Laboratory Inc UL 94 Tests for Flammability of Plastic Materials for Parts in Devices and Appliances e UL 493 Standard for Safety for Thermoplastic Insulated Underground Feeder and Branch Circuit Cables e Traffic Signal Control Equipment Specifications January 1989 edition and applicable addenda State of California Business Transportation amp Housing Agency e State of California Department of Transportation CALTRANS Qualified Products List QPL Controller Assemblies for the Model 170 2070 Traffic Controller e CALTRANS Transportation Electrical Equipment Specifications TEES August 16 2002 and applicable addenda e Georgia Department of Transportation Qualified Products List 75 Polyur
133. rt optional cabinet mounting The UPS shall provide continous fully conditioned and regulated sinusoidal AC power to all of the devices in the traffic signal cabinet including but not limited to controller lighted street name Signs video equipment ethernet switches modem etc The UPS shall not overdrive LED signal heads causing early degradation low luminouisty or early signal failure The UPS shall provide the user with 3 sets of normally open NO and normally closed NC single pole double throw SPDT dry relay contact closures available on a panel mounted terminal block rated at a minimum 120V 1A and labeled so as to identify each contact For typical configuration see Figure 925 5 1 The first set of NO and NC contact closures shall be energized whenever the unit switches to battery power Contact shall be labeled or marked On Batt 2 The second set of NO and NC contact closures shall be energized whenever the battery approaches approximately 40 of remaining useful capacity Contact shall be labeled or marked Low Batt 3 The third set of NO and NC contact closures shall be energized two hours after the unit switches to battery power Contact shall be labeled or marked Timer 4 Relay contact activation shall be annunciated on the front panel via a visual indication This can be either discreet LED or part of LCD screen etc Figure 925 5 Relay Contacts NO NC available on panel mounted terminal blo
134. s C The device shall accept 6 through 20 AWG wire d The device shall accept dual strip jumpers to connect adjacent terminal blocks together e The metal parts shall be made of high grade strain crack and corrosing proof high grade copper alloy f The insulation material shall be inflammability class in accordance with UL 94 g The terminal blocks shall be provided in the following colors Black White Green ground d DIN Rail Provide DIN Rail with current rating of 65 A Ground current The DIN Rail shall be steel which is zinc electroplated with yellow chromate passivation and be in accordance with CENELEC EN50022 DIN Standard 46277 3 The DIN Rail shall be 1 38 inch 35 mm wide by 3 inches 75mm height by 39 inches 1 meter length The DIN Rail shall be cut to size in accordance with the plans The DIN Terminal Strip shall be provided with end covers to match the terminal blocks provided under this specification DIN terminal strip jumpers shall also be provided as indicated in the plan details with center jumper compatible with terminal strip provided Provide terminal strip spacers as indicated in the plan details which match the terminal strip provided e Fastener fastener Hardware and Mounting Hardware All fasteners and fastener hardware shall be stainless steel unless indicated otherwise B Fabrication General Provisions 101 through 150 C Acceptance General Provisions 101 through 150 D Materials Warranty Refe
135. s moving or stopped at distances greater than three feet for any loop perimeter Detect all vehicles over multiple turn and or multiple loops that may he connected in series parallel or series parallel with homerun lengths from 5 feet 1 5 m to gt 1 500 feet 1 000 m 4 Optional Features In addition to the requirements listed in the previous sections the units may be requested with any combination of the following optional features a Option 1 Timing Features Delay amp Extension When this option is specified ensure that the unit incorporates the following features 1 Delay Timing Minimum selectable delay time of 1 to 30 seconds in minimum 1 second increments for each channel 2 Extension Timing Minimum selectable extension time of 0 5 to 10 seconds in minimum 0 5 second increments for each channel b Option 2 Advanced Features When the option for advanced features is specified supply units that incorporate the following advanced features 1 Serial Port Interface When the serial port interface is specified equip the detector with a front and rear panel RS 232 port for the transmission of data Provide Windows 95 compatible software for interfacing with the detector 2 PC Interface Ensure that PC software when connected directly to the unit through the front panel RS 232 port provides a screen to display the following loop system operating characteristics on a per channel basis for system setup data collec
136. s between adjoining cabinet components sides and bottom are continuously welded on the outside to prevent the intrusion of moisture and dust Ensure that all welds are free of cracks blow holes and other irregularities The exterior dimensions of the cabinet are as follows Minimum Maximum Height 14 inches 350 mm 18 inches 450 mm Width 10 inches 250 mm 14 inches 350 mm Depth 12 inches 300 mm 16 inches 400 mm Supply a cabinet door that is double flanged on all four sides to prevent the entry of dirt and liquids when the door is open Use a one piece gasket that is formed around the door opening to insure a weather tight seal when the door is secured Attach the door to the cabinet housing with a continuous tamper proof hinge Provide each cabinet with a Corbin 2 lock and one key Police panel type locks are not acceptable Supply each cabinet with an aluminum back panel mounted on standoffs to facilitate mounting of internal components Supply cabinets with exterior aluminum mounting brackets which extend a minimum of 1 75 inches 44 mm and a maximum of 2 5 inches 63 mm from the top and bottom of the cabinet Use brackets that extend across the full width of the cabinet back on the top and bottom Provide these brackets with holes for mounting to a flat surface with screws and vertical slots for banding to steel concrete or wooden signal poles 50 of 84 Office of Traffic Safety amp Design Section 925CL T
137. sily be accomplished by a PC and provide datakey and programming device with the delivery of the first unit ordered Orders of multiple ITS cabinets require delivery or 1 programming device with PC software for every 10 cabinets Logging Ensure the Type 212 CMU maintains a non volatile event log recording The complete intersection status as well as previous fault events AC Line events configuration changes monitor resets cabinet temperature and true RMS voltages for all field inputs A real time clock time shall stamp each log event with the time and date 37 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Ensure a Signal Sequence History Log is stored in nonvolatile memory The information stored in the signal sequence log shall provide graphic displays of up to 30 seconds of signal status prior to the fault trigger event with 50 ms resolution The Type 212 CMU shall be provided with PC Software that allows a review of status event log review and archival 12 Type 214 ITS Auxiliary Monitor Unit a Introduction Supply each ITS cabinet output assembly with a Type 214 ITS Auxiliary Monitor Unit AMU Ensure the Type 214 CMU meets the CALTRANS TEES Specifications and functions with the a Type 212 Cabinet Monitor Unit to provide cabinet monitoring functions to perform the following monitoring functions Cabinet Power Supplies Conflicting Channel Monitor Serial Bus 1 and 3 Error Message 62
138. sponse time Voltage never exceeds 280V during surge Spike suppression for 700 V spike 40 V deviation from sine wave at all phases angles between 0 and 180 degrees e Provide a protector that is modular and uses a 12 pin Beau connector with the following terminals e Main Line AC line first stage terminal 9 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment e Main Neutral AC neutral input terminal e Equipment Line In AC line second stage input terminal 10A e Equipment Line Out AC line second stage output terminal 10A e Equipment neutral out neutral terminal to protected equipment e GND Earth connection e Supply a protector that is epoxy encapsulated in a flame retardant material e Configure the Equipment Line Out to provide power to the Type 2070 and to the 24 V power supply AC Interconnect Cable Inputs Use a surge protection device to protect each AC interconnect line as it enters the cabinet with a surge protection device that meets or exceeds the following requirements e 3 electrode gas tube type of surge arrestor e Striking voltage of 300 500 V DC with a minimum holder over voltage of 155V DC e Athree terminal device one of which is connected to ground the other two are connected across each input respectively e The units must meet the following minimum requirements Impulse breakdown Impulse breakdown balance Energy application Less
139. ss the full width of the cabinet back on the top and bottom Provide these brackets with holes for mounting to a flat surface with screws and vertical slots for banding to steel concrete or wooden signal poles 2 Flasher Unit Supply a standard plug in two circuits NEMA flasher 48 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Ensure that the flasher is of all solid state construction meets the requirements of the NEMA Standards and is rated at a minimum of 10 A per circuit Ensure that the flasher utilizes zero voltage turn on and turn off current and is capable of dimming outputs 3 Surge Arrestor Supply a flasher cabinet that incorporates an AC surge arrestor to protect the internal components from lighting and over voltages on the AC service input The requirements for the surge arrestor are Two Stage Arrestor Peak Surge Current 20000 A Peak Surge Voltage 20KA 280 V Clamp Voltage 280 V amp 20 kA Continuous AC Voltage 120 V AC RMS Response Time 5 nsec Operating Temp 40 F to 185 F 40 C to 85 C 4 Circuit Breaker Include a 15 Amp circuit breaker in the cabinet The circuit breaker shall have the following characteristics Thermal Magnetic 1 pole 120 240 V AC at 50 60 Hz 15 A Interrupting Rating of 10KA at 48 VDC Wire Size 14 to2 AWG 35 MM Din Rail mounting 5 Terminal Block Include a four position terminal block in the cabinet for making fi
140. t 5 8 11 14 17 20 23 26 29 32 35 38 41 2070 Output 11 32 6 3 34 30 27 33 22 19 35 54 51 2070 Output Port 2 4 5 1 1 7 1 4 5 3 4 7 4 4 5 2 37 34 54 7 7 7 4 AMU Pin B17 B18 B19 B20 B21 B22 B23 B24 B25 B26 B27 B28 B29 AMU Channel 2 3 4 5 6 7 8 9 10 11 12 13 14 Field Term TR 23 4 TR 33 4 TR 43 4 TR 53 4 TR63 4 TR 73 4 TR 83 4 TR 93 4 TR 103 4 TR 11 3 4 TR 12 3 4 TR 13 3 4 TR 14 34 Function Ph2Yel Pd2PC Ph3Yel Ph4Yel Pd4PC Ph5Yel Ph6Yel Pd6PC Ph7Yel Ph8Yel Pd8PC OvAYel OvB Yel SIU Pin A3 B4 A6 B7 A9 B10 A12 B13 A15 B16 A18 B19 A21 B22 SIU Byte Bit 2 2 2 5 3 0 3 3 3 6 4 1 4 4 4 7 5 2 5 5 6 0 6 3 6 6 7 1 SIU Output 3 6 9 12 15 18 21 24 27 30 33 36 39 42 2070 Output 15 12 9 7 4 1 31 28 25 23 20 17 55 52 2070 Output Port 2 8 2 5 2 2 1 8 1 5 1 2 4 8 4 5 4 2 3 8 3 5 32 7 8 7 5 AMU Pin A16 A17 A18 A19 A20 C21 C22 C23 A24 A25 A26 A27 A28 A29 AMU Channel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Field Term ITR 15 6 TR 25 6 TR 356 TR45 6 TR 55 6 TR 65 6 TR 75 6 TR 856 TR 95 6 TR 105 6 TR 115 6 TR 125 6 TR 13 56 TR 14 5 6 Function Ph1 Grn Ph2Grn Pd2W Ph3 Grn Ph4 Grn Pd4W Ph5Grn Ph6 Grn Pd6W Ph7 Grn Ph8 Grn Pd8W OAGm OB Grn 41 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Input File Channel 1 SIU Pin A5 A7 A8 A9 A10 A11 SIU Port 2 6 3 2 3 4 3 6 4 0 4 2 4 4 5 2 5 4 SIU In 7 11 13 15 17 19 21 27
141. t are fully digital and self tuning Ensure that each channel of the unit can automatically tune to any loop and lead in combination within two 2 seconds of application of power or when a reset signal is received Ensure that the tuning circuit is designed so that drift caused by environmental changes or changes in applied power does not cause false actuations Scanning Supply units that sequentially scan each channel only one channel energized at any given time to eliminate crosstalk from multiple loops in adjacent lanes and or allow overlapped loops for directional control and or allow use of multi conductor homerun cable when connected to the same detector unit 52 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment c Sensitivity Setting Ensure that each channel is equipped with front panel selectable sensitivity settings in presence and pulse modes d Frequency Supply units that have a minimum of three switch selectable operating frequencies e Inductance Range Ensure that each channel can tune to an inductive load from 50 to 2000 microhenries with a Q factor gt 5 f Grounded Loops Ensure that each channel can continue to operate with poor quality loop systems Q 2 including those that have a single point short to ground g Fault Monitoring Supply units that constantly monitor the operation of each channel Ensure that the unit detects shorted loops open circuit loops or s
142. t illuminated the symbols are not to be distinguishable by Pedestrians at the far end of the crosswalk they control Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 14 Optically Programmed Signal Head A Requirements Supply signal heads that permit the visibility zone of the indication to be determined optically and require no hoods or louvers The projected indication may be selectively visible or veiled anywhere within 15 degrees of the optical axis Ensure that no indication results from external illumination and that one light unit does not illuminate a second The components of the optical system include the lamp lamp collar optical limiter diffuser and objective lens Ensure that the optical system accommodates projection of diverse selected indications to separate portions of the roadway such that only one indication will be simultaneously apparent to any viewer Ensure that the projected indication conforms to ITE transmittance and chromaticity Standards 1 Construction a Provide an LED Lamp Module that is a direct replacement for the incandescent lamp Ensure the Lamp modules are on the latest CALTRANS QPL for LED Programmed Visibility Modules Ensure the unit provided operates 56 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment over the
143. t will turn off the counter if the steady Don t Walk Display starts while the countdown timer is displaying a number other than 00 B Fabrication General Provisions 101 through 150 C Acceptance General Provisions 101 through 150 63 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment D Materials Warranty Ensure that LED traffic signal modules and LED Pedestrian modules are performance warranted to be in compliance with the latest ITE minimum intensity Standards for LED traffic signal modules measured at 120 V AC and 165 F 74 C for a period of five 5 years Ensure that the manufacturer s name part number date code and electrical characteristics of the LED signal module is visible on the assembly and that each LED signal module is identified for warranty purposes 925 2 17 Blank Out Signs A Requirements Ensure that each sign provides a clearly visible and definable legend for 500 feet with ample safety factors Provide hardware to mount the sign on standard 1 5 inch 38 mm pipe brackets or to mount directly to signal mast arms or span wire or as outlined in the Plans Ensure LED blank out signs conform to the requirements of section 9252 15 for LED modules and optical requirements Supply blank out signs face 30 inches x 30 inches 750 mm x 750 mm that are capable of displaying one message at a time in one direction 1 Case Use a case formed from aluminum extrusion F
144. te or TS Transparent Substrate and do not exhibit degradation of more than 3046 of their initial light intensity following accelerated life testing operating at 185 F 85 C and 85 humidity for 1000 hours AIGaAs technology is not acceptable Supply Green LEDs that utilize gallium nitride technology Table 925 19 Minimum Maintained Luminous Intensity Values for Circular LED Indications Angle Candela Angle Candela 12 inch 300 mm 12 inch 300 mm 59 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Table 925 19 Minimum Maintained Luminous Intensity Values for Circular LED Indications Candela Ange candela 12 inch 300 mm Yellow Yellow 5 Vehicle Arrow Signal Modules Supply LED Arrow Signal Modules that fit in standard incandescent vehicle traffic signal housings and meet the Performance specification of ITE Vehicle Traffic Control Signal LED Vehicle Arrow Traffic Signal Supplement Ensure that Arrow Signal Modules provided are omni directional and marked as OD so that they may be rotated at any angle Ensure the Arrow modules Photometrics support the luminous intensity as indicated in table 925 20 Supply arrow LED Modules that have a full filled profile without the individual LED s being visible Before delivery of any modules supply certification that module is to be in compliance with these specifications In additio
145. ted in accordance with ASTM C1028 Furnish covers with stainless steel hold down bolts minimum size 3 8 16 Furnish covers with the logo TRAFFIC SIGNAL for pull box Types 1 2 and 3 and with other pull box types when installed for traffic signal cabling at a traffic signal Unless otherwise shown in the Plans or installed for traffic signal cabling at a traffic signal furnish covers with the logo CLAYTON COUNTY DOT for pull box Types 4 4S 5 5S 6 and 7 Furnish pull box Types 4 5 6 and 7 with factory installed cable racks and rack hooks Cable racks and rack hooks shall be hot dipped galvanized steel Each cable rack rail shall be minimum 24 inches 600 mm in length with rack hook mounting holes on the entire length Install two racks on each of the pull box long side walls For Type 4 and 5 pull boxes only each cable rack rail may be comprised of two minimum 12 inch 300 mm units installed on the stacked box side walls Mount cable racks to the side walls using minimum 3 8 16 stainless steel hardware Furnish a minimum of four rack hooks minimum 6 inch length 150 mm per pull box Furnish an additional four rack hooks for each through cable stored in the pull box Furnish an additional two rack hooks for each splice closure stored in the pull box 73 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Furnish Types 6 and 7 pull boxes with factory installed non metallic con
146. th ultraviolet stabilizers added for retention of color Use guy guards which are yellow unless otherwise directed B Fabrication General Provisions 101 through 150 C Acceptance General Provisions 101 through 150 D Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 44 Guy Strain Insulators A Requirements Ensure guy strain insulators are protected from the environment including the effects of voltage ultraviolet rays and acid rain by a fully bonded electrically tack free and impenetrable silicone rubber sheath Ensure that insulators attach to the guy so that they cannot easily be removed Each insulator shall be UL proof tested and permanently marked to show date of test Ensure that all guy strain insulators are fiberglass with 15 000 lbs minimum strength minimum 24 inches in rod length and include two 2 clevis end fittings with two 2 rollers B Fabrication General Provisions 101 through 150 C Acceptance General Provisions 101 through 150 D Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 45 Universal Closure Kit A Requirements Supply a Universal Signal Closure Kit to seal the signal head at either the top or bottom Ensure that the kit will fit any manufacturer s signal head top or bottom without the use of special tools or modification 1 Ensure that the gasket is 60 70 durometer neoprene 77 of 84 Office of Traffic Safety amp Design
147. that Pedestrian Signal Modules have prominent and permanent markings to designate the proper orientation of the signal module in the pedestrian signal housing This marking should be an up arrow or the word UP or TOP Ensure Pedestrian Signal Module meets the photometric requirements as indicated and described in the ITE PTCSI LED Pedestrian Traffic Signal Module Specification Supply Portland Orange LEDs that utilize AllnGap technology either AS Absorbing Substrate or TS Transparent Substrate and do not exhibit degradation of more than 30 of their initial light intensity following accelerated life testing operating at 185 F 85 C and 85 humidity for 1000 hours AlGaAs technology is not acceptable Supply White LEDs that utilize InGaN technology B Fabrication General Provisions 101 through 150 C Acceptance General Provisions 101 through 150 D Materials Warranty Ensure that LED traffic signal modules and LED Pedestrian modules are performance warranted to be in compliance with the minimum intensity values as shown in Table 925 19 Provide independent laboratory test results indicating that LED indications satisfy the minimum intensity Standards for LED traffic signal modules measured at 120 V AC and 165 F 74 C for a period of five 5 years Ensure that the manufacturer s name part number date code and electrical characteristics of the LED signal module is visible on the assembly and that each LED signal modu
148. the attached drawing Wire all components together as a working unit thus requiring only field connections of the AC power and flashing beacons Fabrication Refer to Subsection 925 2 07 A 1 for controller cabinet minimum fabrication Specifications Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 09 Time Clock A Requirements Supply time clocks that are single circuit calendar programmable solid state fully self contained units RTC AP 22 that meet the following Specifications 1 2 Alphanumeric liquid crystal display Automatic daylight savings time and leap year compensation Changes in the daylight savings time program made through the keypad do not require hardware modification 51 of 84 Office of Traffic Safety 8 Design Section 925CL Traffic Signal Equipment SO ge lr Gy pi cde D Minimum twenty four 24 hour capacitive back up Battery back up is not acceptable RTC shall be programmed using radio communication with all features keypad radio and PC Operate on 95 to 135 V AC 60 Hz line current SPDT relay output rated at 15 A Maximum size of 4 25 inches 110 mm wide 8 25 inches 210 mm high and 2 inches 50 mm deep A programming manual is to be included with each unit Ability to do program transfer from unit to unit Include program transfer cable with unit 10 Ability to run minimum six 6 di
149. the Field Controller Unit Parallel Input Output Ports other Module Circuit Functions includes muzzle jumper Serial Communication Circuitry Module Connectors CIS C11S and C12S mounted on the module front plate VDC Power Supply 12VDC to 5VDC and required software Ensure it contains any configuration jumpers to be compatible with current GDOT Applications software Ensure the 2070 2A field I O Module functions with a Model 2070L or 2070LB Controller Assembly and is compatible with current GDOT applications software 4 20702B Field I O Module The 2070 2B Field I O module may be supplied as a separate item and consist of the Serial Communication Circuitry DC power Supply and Module Connector 12S mounted on the module front plate only Ensure it contains any configuration jumpers to be compatible with current GDOT Applications software Ensure the 2070 2B field I O Module functions with a Model 2070 LC or 2070LN1 Controller Assembly and is compatible with current GDOT applications software 5 20702N Field I O Module The 2070 2N Field I O module may be supplied as a separate item and provides a NEMA TS2 1compatible SDLC interface via Serial Port 3 AC power to the 2070 Unit and Fault Monitor Logic Output via 2070 Serial Port 5 and Output Frame Byte 9 Bit 6 to the NEMA TS2 Cabinet Monitor Unit CMU Ensure it contains any configuration jumpers to be compatible with current GDOT Applications software Ensure the 2070 2N field I O Module func
150. the LED Signal Module manufacturer to calculate the expected useful life Supply modules with permanent markings of date of manufacture and date of installation Ensure that the Type 1 LED signal modules utilize the same mounting hardware that is used to secure the incandescent lens and gasket assembly Optical All Modules Provide test data from an independent laboratory to verify that the performance of the product meets current ITE requirements Provide LED modules that are of uniform appearance for all circular indications arrow indications and hand and person pedestrian displays Ensure that the individual LEDs are wired such that a catastrophic failure of one LED will result in the loss of not more than 5 of the signal module light output The failure of a single LED in a string or cluster of LED s causes loss of light from only that LED not the entire string or indication Provide control circuitry that prevents the current flow through the LEDs in the off state to avoid any false indications as may be perceived by the human eye during daytime and nighttime hours Ensure that the LED signal module is operationally compatible with existing or new supplied conflict monitors NEMA TS 1 NEMA TS 2 Model 210 Model 2010 ITS Cabinet CMU and AMU Ensure that the LED Signal Module is operationally compatible with existing or new supplied load switches Electrical All Modules Supply LED signal modules that operate over the temperatu
151. the Signal Monitor is able to detect that a channel has not provided an adequate Yellow Clearance interval during a green to yellow to red sequence A Sequence failure SEQUENCE shall be a 13 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment latching fault Ensure that this function is enabled on a per channel basis using dip switches mounted on the PCB labeled CH1 through CH16 Ensure that the Sequence monitoring function is enabled for all selected channels except when the Red Enable input is not active or pin EE is active 10 To Clearance Recognition Time Ensure that the Yellow Clearance interval is 2 7 seconds 11 Flickering Indication Detection Ensure that the Signal Monitor provides a method of detecting Conflict Red Fail and Dual Indication faults that result from intermittent or flickering field signal inputs that may not meet the duration requirements but continue to flicker for an extended period of time These flickering indications shall result in a latching fault with an indication illuminated along with the resulting Conflict Red Fail or Dual Indication indicator Provide an option switch to disable this option 12 Configuration Change Monitoring On power up reset and periodically during operation ensure that the Signal Monitor compares the current configuration settings with the previously stored value and if the settings have changed the Signal
152. there is a plate in the bottom of and or top of any sections where sections adjoin to another section 8 Provide Signal Heads that use stainless steel hardware and are weather tight Ensure signal heads that are supplied are sealed for mounting in all possible configurations 9 Provide Signal Heads that have housing door that positively latches using two eyebolts and wing nuts Ensure the Signal door has hinge lugs molded on one side and two latch jaws are molded on the other side 10 Provide signal heads that provide a positive method of holding the lens such that the lens does not rotate Ensure the lens is weather tight Lens clips which do not apply firm pressure to the lens gasket to avoid rotation are not acceptable When constructing side by side signal sections ensure that both doors can open at the same time butterfly When doors are open ensure that the door will remain attached to housing Ensure bottom section has drainage holes 55 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment B C Fabrication Refer to ITE Standards for material composition and finish Specifications Acceptance Refer to ITE Standards for material composition finish Specifications and wind loading requirements D Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 13 Pedestrian Signal Head A Requirements B C D Provide each section with a visor en
153. tion and diagnostics e Loop Status e Loop Inductance uH e Loop Frequency kHz e Inductance Change nH e Last Fault Open Shorted gt 25 AL e Fault Occurrence Date amp Time e Vehicle Count 3 Speed Volume amp Occupancy The software when connected directly to the unit is capable of collecting and storing speed volume and occupancy data from each detector channel The software allows assignment of loop to loop distances to enable accurate speed and vehicle length measurements The speed volume and occupancy information is uploaded and stored in the vendor supplied software Upon request supply the necessary information protocols to allow the Department to write custom software to retrieve speed volume and occupancy data B Fabrication General Provisions 101 through 150 54 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment C D Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 11 Loop Sealant A Requirements Furnish and install loop sealant according to Subsection 833 2 09 Polyurethane Sealant for Inductive Loops For a list of sources see QPL 75 Fabrication General Provisions 101 through 150 Acceptance General Provisions 101 through 150 Materials Warranty Refer to Subsection 925 2 01 D for Materials Warranties 925 2 12 Vehicle Sig
154. tions with a Model 2070 LN2 Controller Assembly and is compatible with current GDOT applications software 6 2070 3B Front Panel Display Module The 2070 3B Display Module may be supplied as a separate item and provides a Front Panel Assembly controller two keyboards AUX switch alarm bell and an 8 line by 40 character display This assembly shall also include a panel with latch assembly and two TSD 1 hinge attaching devices assembly PCB external serial port connectors CPU active LED indicator contrast adjustment knob and Front Panel Harness Ensure it contains any configuration jumpers to be compatible with current GDOT Applications software Ensure the 2070 3B Front Panel Assembly 5 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment 10 11 12 13 Module functions with Models 2070L 2070LC 2070LN1 and 2070 LN2 Controller Assemblies and is compatible with current GDOT applications software Ensure the hardware hinge attaching devices mate with existing 2070 assemblies Ensure the Front Panel Harness is connected to the front panel via a removable connector Ensure the front panel connector supports the aux switch 2070 3C Front Panel Display Module The 2070 3C Display Module may be supplied as a separate item and provides a System Serial Port 6Lines Isolated and vectored to Connector C60S This assembly shall also include a panel with latch assembly and two TSD 1 hinge attaching
155. udden changes in inductance 22546 of nominal Ensure that each type of fault is indicated on a fault LED by a unique sequence of flashes until the fault is rectified Ensure that while the channel is in the fault condition the channel output remains in the detect state When the fault is rectified the fault LED continues to emit the sequence signifying the last fault detected but the detect LED and output returns to normal operation h Failsafe Output Ensure that each channel output generates a continuous solid state output to the controller when power to the detector is removed i Operational Modes Supply units with each channel selectable for either pulse or presence modes and that meet the following requirements e Pulse Mode This setting provides a single output pulse 125 ms 25 in response to a vehicle entering the loop If a vehicle remains in the sensing zone in excess of two 2 seconds the unit tunes out said vehicle The channel is then capable of detecting another vehicle entering the same detection zone e Presence Mode The presence hold time is a minimum of four 4 minutes for small vehicles motorcycles and a minimum of sixty 60 minutes for automobiles Ensure that the unit tunes out of continuous peak hour traffic over long or multiple small loops as long as there is vehicle motion in the sensing zone every ten 10 minutes j Resets Ensure that the channels are manually resettable by removing the power mom
156. uration as shown in Tables 925 13 925 15 and 925 16 for ITS cabinets using a traffic signal application e 2070LC Provide Chassis 2070 1B Single Board CPU 2070 2B Field I O Module 2070 3B Front Panel 8x40 display 2070 4B 3 5 amp Power Supply and a 2070 7A Module This unit is intended for interfacing in ITS cabinets only and shall provide the default input and output configuration as shown in Tables 925 13 925 15 and 925 16 for ITS cabinets using a traffic signal application e 2070 LB Provide Chassis 2070 1B Single Board CPU 2070 2A Field I O Module 2070 3C Front Panel 2070 4B 3 5 amp Power Supply This unit is intended for interfacing in Type 170E or ITS cabinets where a user interface is not required and shall provide the default input and output configuration as shown in Tables 925 13 925 15 and 925 16 for ITS cabinets using a traffic signal application e 2070 LNI Provide Chassis 2070 1B Single Board CPU 2070 2B Field I O Module 2070 3B Front Panel 8x40 display 2070 4NB 3 5 amp Power Supply 2070 8 NEMA Interface Module and a 2070 7A Module This unit is intended for interfacing in NEMA TS 1 or NEMA TS 2 Type 2 cabinets e 2070 LN2 Provide Chassis 2070 1B Single Board CPU 2070 2N Field I O Module 2070 3B Front Panel 8x40 display 2070 4NB 3 5 amp Power Supply and a 2070 7A Module This unit is intended for interfacing in a NEMA TS 2 Type 1 cabinet 2 Power Supply Modules Either the 2070 4A 2070 4B 2070 4
157. urges and over voltages Design the surge protector panels to allow for adequate space for a wire connection and surge protector replacement without the removal of terminal blocks or panels Provide surge protectors for the input sections as detailed below and as shown in the Input Terminal and Surge Arrestor Detail Supply surge protectors that meet the following Specifications a AC Service Input Include a surge protection unit for each cabinet on the AC service input that meets or exceeds the following requirements e Provide a hybrid type power line surge protection device on a service panel which plugs into a 12 pin Beau Connector which mounts on a service panel Install the protector between the applied line voltage and earth ground Use a surge protector capable of reducing the effect of lightning transient voltages applied to the AC line that conforms to the following Peak surge current for an 8 x 20 us waveform 20 000A for 20 occurrences Clamp voltage 20 000A 280V max Maximum continuous operating current 120V 60 Hz 10A Series Inductance AC Line AC Neutral 200 microhenries Response time Voltage never exceeds 280V during surge Spike suppression for 700 V spike 40 V deviation from sine wave at all phases angles between 0 and 180 degrees e Provide a protector with the following terminals e MainLine AC line first stage terminal e Main Neutral AC neutral input terminal e Equipment Line In AC line second stage
158. usion The ends caps shall be affixed to the frame with stainless screws The end caps shall be removable to enable replacing panels and components 4 The overall weight excluding mounting hardware shall not exceed 7 pounds per square foot for single sided signs and 8 pounds per square foot for double sided signs 5 The sign shall have a polycarbonate panel that is UV weather abrasion and impact resistant The front panel shall be replaceable so that maintaining agencies have the option to supply their own sheeting and cut film for the sign faces 6 Sign frames and attached termination boxes shall have a factory applied black TGIC polyester urethane powder coating electrostatically applied inside and outside 7 The sign assembly shall include a raintight termination box on the right end of the assembly as facing the sign legend The termination box shall provide signal sign power cable entry and cable strain relief through the bottom of the box and a touchsafe tubular compression terminal block shall be provided for direct termination of stripped signal cable conductors The termination box shall provide for cable entry strain relief and sign power conductor termination of a minimum 7 conductor 14AWG stranded IMSA 20 1 signal cable The termination box cover shall be manufactured of the same material and finish as the sign frame and shall include a lanyard to prevent the cover from falling during signal cable installation b Environm
159. ut channel which meets the same requirements as the communication inputs with the following exception of the Voltage clamp which shall be 30 V line to line Ethernet Inputs All Ethernet devices entering and leaving cabinet shall pass through an RJ45 surge suppression module Mount on DIN Rail grounded 11 Type 212 ITS Cabinet Monitor Unit a Introduction Supply each cabinet with Type 212 ITS Cabinet Monitor Unit CMU Ensure the Type 212 CMU meets the CALTRANS TEES Specifications and functions as a unit with the a Type 214 Auxiliary Monitor Unit to provide the following monitoring functions Cabinet Power Supplies Conflicting Channel Monitor Serial Bus1 and 3 Error Message 62 Diagnostic Error Multiple Channel Inputs Lack of Signal Inputs Yellow Clearance Yellow plus Red Clearance Police and Power Distribution Switch Monitor door Switches and Main Contactor Status Circuit Breakers Flash Unit Output Status and AC Line Level Sense Ensure the Unit supplied is listed on the most recent California Department of Transportation Qualified Products List QPL Configuration Supply Type 212 CMU capable of monitoring up to 28 physical load switch channels RYG plus 4 virtual channels for a total of 32 channels Programming Ensure complete programming of the Type 212 CMU is by an interchangeable Datakey nonvolatile memory device The Datakey shall store all of the configuration parameters Ensure the programming of the datakey can ea
160. ut clamped on power up and down e Compatible with 2070 controllers and latest version of CALTRANS TEES including errata Model 200 Switchpack Provide Model 200 Switchpacks that are in accordance with the latest version of CALTRANS Specifications as referenced earlier in this section Model 204 Flasher Unit Provide Model 204 Flasher Units that are in accordance with the latest version of CALTRANS Specifications as referenced earlier in this section Flash Transfer Relay Provide Flash Transfer Relays that are in accordance with the latest version of CALTRANS Specifications as referenced earlier in this section Cabinet Model 332A Provide Cabinet Model 332A that meets the CALTRANS Specification with the addition of surge protection as detailed in Table 925 4 Model 332A Default Input Files Assignment Detail and Table 925 5 Required Surge Arrestors for Model 332A Cabinet Supply Model 332A lower input panel cabinets with housing Type 1B and all components as described in these Specifications 21 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment Supply cabinets having two input files which conform to the CALTRANS Specifications and configured to accept two 2070 controllers in the top portion of the cabinet Ensure the cabinet has two shelves provided for controller s Provide contact closure door switches to sense door open conditions Configure the switches so that any single
161. wer dissipation rating of 0 5 Watts or greater and a voltage rating exceeding 350 volts Component Specifications Ensure that all electrical components used in the Signal Monitor are rated by the component manufacturer to operate beyond the full unit operating temperature range of 29 F to 165 F 34 C to 74 C 19 of 84 Office of Traffic Safety amp Design Section 925CL Traffic Signal Equipment i Printed Circuit Boards Ensure that all printed circuit boards meet the requirements of the California Traffic Signal Control Equipment Specifications January 1989 plus the following requirements to enhance reliability i All plated through holes and exposed circuit traces are plated with solder ii Both sides of the printed circuit board are covered with a solder mask material iii The circuit reference designation for all components and the polarity of all capacitors and diodes are clearly marked adjacent to the component Ensure that Pin 1 for all integrated circuit packages is designated on both sides of all printed circuit boards iv All electrical mating surfaces are gold plated y All printed circuit board assemblies are coated on both sides with a clear moisture proof and fungus proof sealant vi All components and wire harnesses are mounted to the PCB using plated holes Piggy back connections or jumper wires are not acceptable 15 Model 208 Monitor Unit Provide Model 208 Monitor Unit in accordan
162. xes are a matched assembly of a box and cover from the same manufacturer For all pull boxes except Types 4 and 5 use pull boxes manufactured in a single unit for the full depth required in the size in an open bottom configuration Do not use stacked pull boxes For pull boxes Types 4 and 5 use stacked pull boxes as shown in the Plans where the top unit is open bottom and the bottom unit is closed bottom manufacture In the bottom unit provide a drain hole Provide pull boxes that are constructed of fiberglass reinforced composite polymer concrete product or steel wire reinforced portland cement concrete product with a concrete gray or tan color Ensure that pull boxes meet all requirements of ANSI 77 2002 Tier 15 Provide compliance test documentation Provide a 4 inch galvanized wire mesh between the gravel base and the open bottom box or closed bottom box drain hole for all pull box types Use Type 1 pull boxes 12 inches x 12 inches 300 mm x 300 mm for loop lead ins When loop lead ins and splices and other cables are required use Type 2 pull boxes 11 inches x 18 inches 275 mm x 450 mm or Type 3 pull boxes 17 inches x 30 inches 425 mm x 750 mm Use Type 4 4S 5 5S 6 and 7 pull boxes for fiber optic cable Furnish one piece covers for all pull boxes except Types 5 5S and 7 Furnish two piece covers for Types 5 5S and 7 Furnish covers with a skid resistant surface with a minimum coefficient of friction of 0 5 when tes