1. Amino Technical Note 005 Debug Cable Quick Reference February 2011 gt CONTENTS INDEX Amino Communications Ltd 2011 CONFIDENTIAL Copyright Debug Cable Quick Reference 5 February 2011 Issue 109 Amino Communications Ltd 2011 Amino AmiNET AssetHouse Mood and the Amino logo are trademarks of Amino Communications Ltd All other trademarks are the property of their respective owners Confidentiality the information in this document is subject to non disclosure agreements and must not be passed to other third parties without the express permission of Amino Communications Ltd This document describes components that undergo continual development The information in this document is subject to change without notice at any time Comments about the documentation are welcome Please submit feedback to docs aminocom com For further information about Amino or Amino products please e mail info aminocom com Document history 109 11 02 11 Added picture of flexicable 108 14 01 11 Additional information added for modifying and locating the debug header in particular when a case is fitted 107 23 12 10 A129 and H140 pictures added 106 5 10 10 A130Hv2 picture amended as debug position incorrectly shown 105 13 09 10 Mood information added Document changed to new Company format 4 iii gt CONTENTS INDEX Amino Communications Ltd 2011 CONFIDENTIAL Debug Cable Quick Re
2. j 4 lt 3 2 Locating the debug header positions Mood STBs The pictures below highlight where to find the debug connector on each version The header fitted to the Mood STBs 002 020 022 is not polarised so it is possible to fit the debug cable the wrong way round For these versions in each picture the arrow indicates the position of the red wire in the debug cable Remember to remove the debug cable from the set top box before disconnecting the other end of the debug cable from the PC Mood 400 002 Mood 400 020 REE s fe EJ a 4 j Contact side of flexi cabl 4 Amino Communications Ltd 2011 CONFIDENTIA Mood 400 032 Contact side of flexi cable Serial ATA cable removed for clarity 4 Using the Debug Cable To use the Amino debug cable connect the DB9 plug to the serial port on your PC Open your terminal software for example Minicom or Hyperterminal and connect at 115200 bps 8 bits 1 stop bit NO parity and NO flow control Your terminal window should now show the debug output from your STB and allow you to log in to the console COM1 Properties Port Settings Bits per second Data bits Parity Stop bits Flow control The standard Amino username and password are root and root2root 5 Useful Commands This section details some useful commands that can be run using the debug cable in either IntActOS or Linux
3. 02 18 12 C5 Hit ENTER to stop normal operation I gt Connected 00 00 26 Auto detect 115200 8 N 1 5 1 1 Show All The show all command shows the values stored in the NOR flash For example I gt show all Locked 00 BoxID 701306D000085 BoardRev 2 VideoMode 1 OutFormat 2 RFChan 167 RFMode 0 RFFreqTbl 0 CAID FOFOFOFO NDSSoftwareVersion 00000000 NDSDriverVersion 00 ManufacturerID 1D STBModelType O1 HardwareVersion MACaddress 00 02 02 0C 91 E0 Ethernet 0 UseDHCP Y TPaddress Gateway 0 Netmask 0 Tiameserver 0 0 0 0 DNS 0 0 0 0 McastAdr 0 0 0 0 McastPort 0 I gt 5 1 2 Format The format command is used to completely erase the NAND flash and therefore any software loaded onto the box This will put the box into a multicast aware state ready to receive a new software image from a multicast middleware server 5 1 3 Reset The reset command is used to exit from IntActOS 5 1 4 Help Shows all the available commands 5 2 Linux This section has a brief list of useful commands that will help you gather information about the STB Most of these are standard Linux commands Once the box has booted up fully into Linux the console will show the message Please press Enter to activate this console Pressing Enter prompts you for the username and password root and root2root Debug HyperTerminal File Edit View Cal Transfer Help D A el
4. IntActOS is a simple Operating System that is started when the STB is booted It enables the programming of code images and launches Linux the STBs main operating system The debug cable can also be used to view the debug messages which appear on the console as part of the normal operation of the STB For example you will be able to immediately see the status of all stages of a software upgrade see the status of the video engine when playing a clip and track down problems with PID detection among other things 5 1 IntActOS To enter IntActOS 1 2 La Connect the debug cable and power on the STB At the Hit ENTER to stop normal operation prompt press Enter to enter IntActOS The prompt I gt will appear as shown below The following list of useful commands are not case sensitive Debug Hyper Terminal File Edit View Cal Transfer Help a Initialising NOR Flash Amino Communications IntActOS 37 v1 44 on BMINETI1x with 3 Mb BRAM Processor 51510950 running at 252 000MHz 00140000 ASB v1 2 00148000 FIL v1 36 00158000 UL v1 14 00160000 ETH v1 28 00170000 CPT v1 00 BMIHET11x BOOT ROM VERSION 1 34 02 system PAL I Output format CYBS RGBOFF Setting DENCO CRI to 91100040 Setting DENC1 CR1 to 9 1101F40 Setting DENCMUX to 3E000000 iic writte status 00000000 multicast booting PHY LANH63C163 LAN91C111 Internal SM91CIT1IxFD rev 1 at 70100300 IRQ 25 MEMSIZE 9197 ADDR 00 02
5. debug cable to Aminet x4x STBs On the x4x series STBs you can use the standard flexi cable adaptor provided by Amino to extend the cable This can be threaded through the back plate alongside the RJ45 connector so that the STB can be used with the case fitted but still with debug facilities available Amino Communications Ltd 2011 CONFIDENTIAL INDEX CONTENTS 47 gt DEBUG CABLE QUICK REFERENCE 48 gt CONTENTS INDEX Amino Communications Ltd 2011 CONFIDENTIAL 2 4 Locating the debug header positions Aminet x4x STBs AmiNET A140 and A129 AmiNET A540 SULA Contact side 2221000000 flexi cable i il Il iti CF4DA Contact side of pf 2 flexi cable 52327 CONTE ATi Contact side of flexi cable GC311000000056 Al LUE 3 Mood STBs 3 1 Connecting the debug cable to Mood STBs Fitting a debug cable to a Mood STB is a simple process Before you start you will need e A Philips head screwdriver or a T 10 torx head screwdriver depending on the model e A debug header Remove the cover retaining screws on the unit and slide the cover backwards and off the STB The header position is in a different place on each of the 002 020 and 022 STBs The header type on the 030 and 032 STBs is the flexi cable type as on the AmiNET x4x series STBs Amino Communications Ltd 2011 CONFIDENTIAL
6. 00 11 643271 warn syslog texttvd client connection read Connection rJan 00 00 11 8645516 info syslog texttvd Client connected to STTP socket Please press Enter to activate this console Jan 1 00 00 12 6402127 info init BMINET login Connected 00 00 26 Auto detect 115200 8 N 1 52 1 lfconfig The ifconfig command tells you the status of the interfaces on the box it will tell you the IP address and subnet mask of the interface and statistics on transmitted and received packets 5 2 2 Route This command shows the routing table The most useful information here is generally the default gateway 5 2 3 Cat proc sys dev ethO Inkfail Running the command cat proc sys dev eth0 Inkfail will return a 1 if the Ethernet link is down and 0 if it is up Other files in this directory are also useful for example aspeed returns the speed of the interface while afduplx will return 1 for full duplex and 0 for half duplex 5 2 4 Vi mnt nv config txt This command opens the browser configuration file in the editor vi Other files in mnt nv that you may wish to edit include settings and netconf Vi is a standard Linux editor and more information on its usage is available on the Internet 5 2 5 Free The free command returns the status of the memory in the box 5 2 6 Reboot A user invoked reset of the set top box 6 Quick Guide to Reflashing an STB It is possible to reflash a box by clearing the memory Thi
7. A Starting subtitle teletext support modules Jan 1 00 00 09 650271 warn syslog layers client fake margins 38 27 42 31 Jan 1 00 00 09 651939 info syslog Spawning mntnv texttvd Jan 1 00 00 09 676583 warn syslog layers client smargins 36 27 42 31 Jan 1 00 00 09 7592 48 info syslog texttvd texttvd with PES input module Jan 1 00 00 09 760496 info syslog texttvd texttvd using Unix domin socket S Jan 1 00 00 09 770384 info syslog texttvd texttvd started Jan 1 00 00 09 771987 info syslog texttvd PURGE cache Jan 1 00 00 10 015757 info syslog HAL SetAspect 1 Jan 1 00 00 10 016972 info syslog pig get state 0 scale 1 x 0 y 0 w 720 h 57 Jan 1 00 00 10 060473 warn syslog gfx layers set ignore updates 0 Jan 1 00 00 10 096614 info syslog sf check ip Acquired IP update time Jan 1 00 00 10 264555 err syslog amino generic lib init Jan 1 00 00 10 286813 info syslog ftmp aminogener ic _create registration soc Jan 1 00 00 10 288041 err syslog create registration socket Done Jan 1 00 00 28689257 info syslog connect to available clients Hunting for Jan 1 00 00 291486 info syslog connect to available clients Found entry Jan 1 00 00 293423 err syslog connect to available clients Failed to con Jan 1 00 00 294923 info syslog connect to available clients Connected to Jan 1 00 00 11 632568 info syslog Spawning mnt nv dvbttx Jan 1 00 00 11 820647 info syslog texttvd Client connected to STTP socket 00
8. CONFIDENTIAL INDEX CONTENTS 43 gt DEBUG CABLE QUICK REFERENCE It is not strictly necessary to solder the debug header in place if it is inconvenient for you to do so However the header pins are not a tight fit in the holes in the pcb so if you do not solder the header in place you may have to apply a slight pressure on the header to ensure good electrical connectivity 2 1 1 Modifying and routing the debug header Extending the header pins The debug header can be modified using Molex headers or equivalent Attaching these headers as shown in Figure 3 gives longer pins for insertion and the plastic frame can be used to provide some compression force to hold the header in place if it is not soldered Molex 0 1 4 way header square pin part number 22 27 2041 Available from http uk farnell com Attaching a ribbon cable In some circumstances for example a test laboratory you may need to use the debug facility with the STB case fitted It is possible to solder a ribbon cable onto the pcb where the debug header would normally be fitted and then route this cable outside the case If you solder a ribbon cable between the debug header and the pcb ensure you connect the cable pin to pin For example use the red wire between the header pin and the square solder pad which it would normally be fitted into then connect the remaining cables in the correct order Routing th
9. e ribbon cable x3x STBs To route the cable out of the STB and allow you to refit the cover we suggest you feed the ribbon cable through one of the holes in the back plate that are used when the STB is mounted vertically 4 4 CONTENTS INDEX Amino Communications Ltd 2011 CONFIDENTIAL DEBUG CABLE QUICK REFERENCE 2 2 Locating the debug header positions Aminet x3x STBs The pictures below highlight where to find the debug connector on the different versions AmiNET103 AmiNET110 5 OL R D000033 Amino Communications Ltd 2011 CONFIDENTIAL INDEX CONTENTS 5 DEBUG CABLE QUICK REFERENCE AmiNET110H AmiNET125 RER RS rast AL CT 3 t eg Pr cy i SIN FA410900012078 MAC 00020223E9E6 11 6 CONTENTS INDEX Amino Communications Ltd 2011 CONFIDENTIAL DEBUG CABLE QUICK REFERENCE AmiNET130M AmiNETS500 T i T BEL ooog gt FREE S N E04908D00407 MAC 0002021A90F1 AY 3 gt 5 o 5 2 a E 3 2 j On the A530EU US it is easier to connect the debug cable to the underside of the PCB When the casing is removed this is the side of the PCB that is exposed but is not the side showing the silk screen However the end pin of the debug header position is still marked with a square solder pad 2 3 Connecting the
10. ference This document decribes how to set up and use the Amino debug cable on the AmiNET and Mood set top boxes STBs The debug cable is essential when testing an STB to aid in the rapid diagnosis of faults and unexpected behaviour It is applicable to the following versions of STB Mood 400 032 M540 1 The Debug Cable 1 1 Aminet x3x and Mood400 002 020 022 STBs The Amino debug cable part number 500 745 has a black connector a light grey plastic breakout box and a DB9 serial connector It is also supplied with a debug header a black connector with 4 pins DEBUG CABLE QUICK REFERENCE 1 2 Aminet x4x and Mood400 030 032 STBs The Amino flexi cable assembly part number 512 857 00 00 CABL BP has a black header and a 4 way flexible cable attached The flexible cable will normally be white or light blue but may vary depending on the supplier 2 AmiNET STBs 2 1 Connecting the debug header to Aminet x3x STBs Fitting a debug header to an AmiNET x3x STB is a fairly simple process Before you start you will need e A Philips head screwdriver e A debug header e Optional A soldering iron and some solder Firstly remove the screws on the rear of the unit and on the A500 disconnect the two cables and then slide the PCB backwards out of the case The debug header fits into 4 holes on the circuit board On each version of STB the location of the header holes is different see Locating the debug header positio
11. ns Aminet x3x STBs for the locations On every STB except the A530 see the note below the silk screen will be as shown in Figure 1 The two features to note are 2 CONTENTS INDEX Amino Communications Ltd 2011 CONFIDENTIAL DEBUG CABLE QUICK REFERENCE e there are two white marks along one side of the silk screening e the end pin is surrounded by a square solder pad These features are both highlighted in red in Figure 1 and are a useful indication of the correct header orientation LED2 042550 Adfa SS aaa RS en DE Len 9 06046 64 0 8 C Amino Communications Ltd 2 P N 002 415 01 00 PCBA E Figure 1 Example header location The debug header has two slots on one edge These slots align with the two white marks highlighted on the pcb silkscreen In addition the square pad indicates the position for the red wire of the debug cable Insert the header pins into the holes on the pcb TI OR ALLEEL F Troe Et il 4 x i i L L 9 Le er gt los purs 2 Debug cable in place 7 If the header and cable are placed the wrong way round the box will not boot up no LEDs will light and there will be no debug output Removing the debug cable and inserting it correctly will return the box to normal operation Remember to remove the debug cable from the set top box before disconnecting the other end of the debug cable from the PC Amino Communications Ltd 2011
12. s will put it into a multicast aware state readyto receive a new software image from a multicast middleware server The easiest way to do this is 1 BW N 6 Connect the debug cable and power on the STB At the Hit ENTER to stop normal operation prompt press Enter to enter IntActOS The prompt I gt will appear as shown above At the prompt type f for format and press Enter It will ask for confirmation press Y Once the format is completed type reset and press Enter to reset the box It will now boot up with the Loading message on the screen and will attempt to load a new image from a multicast server DEBUG CABLE QUICK REFERENCE 4 16 gt CONTENTS INDEX Amino Communications Ltd 2011 CONFIDENTIAL

Download Pdf Manuals

image

Related Search

Related Contents

Clifford Sabre II User's Manual  Illumine CLI-EMM029233 Installation Guide  Seguridad Industrial  Mercury Marine do Brasil 2011 E  Kenroy Home 32492BS Installation Guide  Manual de instalación y uso equipo compactos  User GUide • GUÍa del UsUario    Manual - GRUPO ARFI  Spectra Blitz Service Manual  