1. Server Issue Report A sample form is provided on the following pages However for the fastest service please submit your form via the Internet In U S and Canada 1 800 404 2284 In Europe UK 0870 6072439 Finland 9 693 79297 France 01 41 918529 Denmark 38 487077 Germany 069 9509 6099 Norway 23 1620 50 Italy 02 696 33276 Sweden 08 445 1251 Spain 91 377 8166 Holland 020 487 4562 Belgium 02 714 3182 In Asia Pacific region Australia 1800 649931 Indonesia 803 65 7249 Hong Kong 852 2 844 4456 Malaysia 1 800 80 1390 Korea 822 767 2595 New Zealand 0800 444 365 China 800 820 1100 toll free Pakistan 632 63684 15 IDD via Philippines 8 621 33104691 not toll free Philippines 1800 1 651 0117 Singapore 65 6213 1311 Thailand 1 800 631 0003 India 0006517 2 68303634 manual Vietnam 632 6368416 IDD via Philippines toll free From India you need an Myanmar 63 2 636 9796 via Philippines IDD equipped telephone Cambodia 63 2 636 9797 via Philippines Taiwan 2 2545 1640 In Japan 0120 868686 Domestic 81 298 47 0800 outside country 43 Intel Entry Server Board SE7221BK1 E User Guide Getting Help In Latin America Brazil 001 916 377 0180 Ecuador Andimate Contact AT amp T USA at 1 999 Mexico Contact AT amp T USA at 001 800 119 Once connected dial 800 843 4481 462 628 4240 Once connected Ecuador Pacifictel Contact AT amp T USA at 1 800 dial 800 843 4481 225 528 Once connected dial 800 843 4481 Colombia Contact
2. x8 PCI Express is available optional from the Intel Adaptive Slot technology slot and routed from the MCH The Adaptive Slot is only available on Intel Entry Server Board SE7221BK1 E LX SKU and the Intel Entry Server Platform SR1425BK1 E Table 5 PCI Buses PCIBus Voltage Width Speed Type PCll OCardSlots Segment SC5250 E Pedestal Chassis PCI 5V 32 bits 33 MHz P32 A Slot 1 PCI X 3 3V 64 bits 100 MHz P64 C Slot 4 Slot 5 PCI E x8 3 3 8 lanes 100 MHz Slot 6 SR1425BK1 E Rack Chassis PCI E x8 3 3 8 lanes 100 MHz Adaptive Riser Slot PCI X 3 3V 64 bits 66 MHz Adaptive Riser Slot Riser Options Peripherals and add in cards are not included in your system and must be purchased separately For 1U models you must use the 90 riser option to add in PCI PCI X or PCI Express adapters The 64 bit white slots cannot be used for 1u or if a 90 riser card is installed Riser cards for the Intel Entry Server Board SE7221 BKI E are custom fit and provide either PCI 2 3 or PCI Express capability Please see the available accessories list at http support intel com support motherboards server SE7221 BK1 E Intel Entry Server Board SE7221BK1 E User Guide Hardware Installations and Upgrades 2 Hardware Installations and Upgrades Before You Begin Before working with your server product pay close attention to the Safety Information at the beginning of this manual Tools and Supplies Needed Phillips cross head screw
3. Problems with NeBWOLFTK 224 22 Dess akan Fast Soa nes cust eu Lone et ka k MA Ka k k j ka ula kk ku kak aA UNE 32 System Boots When Installing PCI Card sss 33 Problems With Newly Installed Application Software 33 Problems With Application Software That Ran Correctly Earlier 33 Devices Are Not Recognized Under Device Manager Windows Operating SYSIEM kiss ds a kan duel 34 Hard Drive s Are Not Recognized uu 22 u200a0000an0nanunnanunnnunnnnunnnnnnannnnnnnnnnnnnn 34 Bootable CD ROM Is Not Detected 2u200220000000an00nnnnnanunnannnanunnnnnnnnunn nun 34 Error Handling and Reporting 35 LED INTOrMalloNn nee ee Tune 35 BIOS Event LOG eet nn nase Ba BES Dee 36 BIOS POST Beep Codes nds HAWA K AWR as san HAWA AMARA AWA WAA 37 Regulatory and Compliance Information 39 Product Regulatory Compliance Llc Leere e Lee AA AA AA AA KAKA WAA AWA AW AA AWA AWA AA 39 Product Safety Compliance uu uuauuuunnu0unaununannnnnnn0nnannnnannnnnnnnnnannnnannnnnnnnnnanunnannn 39 Product EMC Compliance Class A Compliance 39 Certifications Registrations Declarations sees 39 Product Regu
4. u 2200220002200nan0nanunannnnnnunnnnnnanunnnnnnnnunnunnnnnunnnnnnanunnnnnn 9 Installing and Removing Memory eseeeeee eee kk kk kk kk kk kk kk kK KA KA KA nnn nnn 10 la ne lT Roge lal DS NNN en a raa 10 ES INO VU DIMMS m 11 Installing or Replacing the Processor uuusuunennannnnnennnnnnnnunnanunnnunnnnnnanennnnnnnnunnnnnnanen nenn 12 INSTALING ENS PLOCESSOL AAPP A 12 Removing the PFOCESSAr u u nnu 15 Installing a PCI PCI X or PCI Express Card esee 16 Replacing the Backup Battery eeeseeee eee kake kk kk kk KAKA Ak nnne nnn 17 3 Sener IIIA UM 20 BIOS SCID 20 COCINA ON a E 20 Consol RedireCtHUON me m 20 Conliduranon ROSE DD idad 20 Keyboard COMMANGS c 21 Upgrading the BIOS ass n nan ban da kawan kanun a nakr k k na d WR Ha kd W G 22 Preparing for the Upgrade uuu002000n an0nnanuonnanunnnnunnnnnonnanunnnnunnnnunnnnnennannnnannnnnnnn 22 BIOS Selection and On line Updates nun nenn 24 PLE COV CMEC Me BIOS 25 Manually Recovering the BIOS ccccsssesseseesees
5. AT amp T USA at 01 800 Guatemala Contact AT amp T USA at 99 99 190 Once 911 0010 Once connected dial connected dial 800 843 4481 800 843 4481 Venezuela Contact AT amp T USA at 0 800 2255 288 Once Costa Rica Contact AT amp T USA at 0 800 0 connected dial 800 843 4481 114 114 Once connected dial Argentina Contact AT amp T USA at 0 800 222 1288 Once 800 843 4481 connected dial 800 843 4481 Panama Contact AT amp T USA at 00 800 Paraguay 001 916 377 0114 001 0109 Once connected dial Peru 001 916 377 0114 800 843 4481 Uruguay 001 916 377 0114 Chile Easter Island Contact AT amp T U SA at 800 800 311 Once connected dial 800 843 4481 Chile Mainland and Juan Contact AT amp T USA at 800 225 288 Once connected dial 800 843 4481 Miami 1 800 621 8423 For an updated support contact list see http support intel com support 9089 htm 44 Intel Server Issue Report Form Intel Entry Server Board SE7221BK1 E User Guide Intel Server Issue Report Form Date Submitted Company Name Contact Name Email Address Intel Server Product Priority Critical Hot High Low Brief Problem Description Provide a brief description below See the last page for space to include a detailed problem description Board Chassis Information Baseboard Revision PBA DIMM Configuration Baseboard Serial Number DIMM1A MB CPU1 Speed Stepping Spec DIMM1A Vendor part number System BIOS Version DIMM1B Vendor part number HSC Fir
6. No 1997 41 EMC amp 1997 42 EMI Korea Certifications Registrations Declarations UL Certification US Canada CE Declaration of Conformity CENELEC Europe FCC ICES 003 Class A Attestation USA Canada 39 Intel Entry Server Board SE7221BK1 E User Guide Regulatory and Compliance Information C Tick Declaration of Conformity Australia MED Declaration of Conformity New Zealand BSMI Certification Taiwan GOST Listed on one System License Russia Belarus Listed on one System License Belarus RRL Certification Korea Ecology Declaration International Product Regulatory Compliance Markings This product is marked with the following Product Certification Markings Table 10 Product Certification Markings Regulatory Compliance Country UL Mark USA Canada Marking AW C US CE Mark Europe F Markin A A s device complies with Part 15 ofthe Rules Operation ee Meng eee is of this device is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Manufactured by Intel Corporation EMC Marking Class A Canada CANADA ICES 003 CLASS A CANADA NMB 003 CLASSE A BSMI Marking Class A Taiwan gt NA ES RAE Da PPAR A E AEREAS gt TEBERHATR TEA HENAN TA gt ERAS KFA Lis ES HIER RRL MIC Mark Korea y Mic i
7. PXE option ROMs for the devices that are embedded on the system board The Setup Utility The System BIOS Preparing for the Upgrade Before you upgrade the BIOS prepare for the upgrade by recording the current BIOS settings obtaining the upgrade utility reviewing the release notes and making a copy of the current BIOS In the unlikely event that a BIOS error occurs during the BIOS update process see Recovering the BIOS for instructions on performing a BIOS recovery Recording the Current BIOS Settings 1 Boot the computer and press lt F2 gt when you see the message Press lt F2 gt Key if you want to run SETUP 2 Write down the current settings in the BIOS Setup program amp NOTE Do not skip step 2 You will need these settings to configure your computer at the end of the procedure Obtaining the Upgrade Download the BIOS image file to a temporary folder on your hard drive See http support intel com support motherboards server SE7221BK1 E for a link to the update software If you chose to Save Custom Defaults after the new BIOS is flashed you can restore your settings from the Load Custom Default option 22 Server Utilities Intel Entry Server Board SE7221BK1 E User Guide gt NOTE Review the instructions distributed with the upgrade utility before attempting a BIOS upgrade Review also any release notes in the release notes file that accompanies the new version of the BIOS The release
8. among multiple diskettes using a splitter utility such as split exe 2 Plug the system into the AC power source and power it on 3 The recovery process will automatically run The system may beep throughout the recovery process The recovery process is complete when the beeping stops 4 Remove the flash media 5 Power down and unplug the system from the AC power source 25 Intel Entry Server Board SE7221BK1 E User Guide Server Utilities NOTE Move the BIOS recovery jumper at JIF2 back to the original position covering pins 9 and 10 Plug the system into the AC power source and power it up to confirm that the recorvery was successful To use splitter exe type the following command at the command prompt split AMIBOOT ROM AMIBOOT 1024 The above command will create the files of sizes IMB each with names AMIBOOT 000 AMIBOOT 001 and so on depending upon the AMIBOOT ROM file size Load the first disk with AMIBOOT 000 It will search the same disk for AMIBOOT 001 If doesn t find the file in the floppy it will beep for one 1 second and search again Clearing the Password If the user or administrator password s is lost or forgotten moving the password clear jumper into the clear position clears both passwords The password clear jumper must be restored to its original position before a new password s can be set The password clear jumper is located on jumper block J1F2 1 Power down the system and disco
9. in English French Italian German and Spanish The BIOS supports these languages for console strings as well Console Redirection The BIOS Setup is functional via console redirection over various terminal emulation standards Due to emulation compatibility reasons some functionality may be limited e g usage of colors some keys and or key sequences and support of some pointing devices Configuration Reset There are different mechanisms for resetting the system configuration to default values When a reset system configuration request is detected the BIOS will load the default system configuration values during the next POST A reset system configuration request can be generated by moving the Clear CMOS jumper 20 Server Utilities Intel Entry Server Board SE7221BK1 E User Guide Keyboard Commands The Keyboard Command Bar supports the following keys Table 6 BIOS Setup Keyboard Command Bar Options Key Enter ESC F9 F7 Option Execute Command Exit Select Item Select Item Select Menu Select Field Change Value Change Value Setup Defaults Discard Changes Description The Enter key is used to activate choices If a pick list is displayed the Enter key will undo the pick list and allow another selection in the parent menu When the ESC key is pressed in any sub menu the parent menu is re entered When the ESC key is pressed in any parent menu the exit confirmation window is displayed and
10. is set to Disabled CD ROM Drive or DVD ROM Drive Activity Light Does Not Light Check the following Q Are the CD ROM DVD ROM drive s power and signal cables properly installed Q Are all relevant switches and jumpers on the drive set correctly Q Is the drive properly configured 31 Intel Entry Server Board SE7221BK1 E User Guide Troubleshooting Cannot Connect to a Server LJ Make sure the network cable is securely attached to the correct connector at the system back panel O Try a different network cable O Make sure you are using the most recent version of the correct device drivers Please see http downloadfinder intel com scripts df support_intel asp for a link to the current drivers Make sure the driver is loaded and the protocols are bound Make sure the hub port is configured for the same duplex mode as the network controller Make sure the correct networking software is installed If you are directly connecting two servers without a hub you will need a crossover cable Check the network controller LEDs next to the NIC connectors U U UL U LL Problems with Network 32 The server hangs when the drivers are loaded LJ Certain drivers may require interrupts that are not shared with other PCI drivers For these drivers it may be necessary to alter settings so that interrupts are not shared See the documentation that came with your PCI card s for information on changing interrupts Diagno
11. notes may contain critical information regarding jumper settings specific fixes or other information to complete the upgrade Creating a Bootable Diskette 1 Use a DOS system to create the diskette as follows 2 Insert a diskette in diskette drive A 3 Atthe C prompt for an unformatted diskette type format a s or for a diskette that is already formatted type sys a 4 Press lt Enter gt Flash Update Utility The BIOS flash utility suite is compatible with DOS Windows and Linux The afuXXX AMI Firmware Update Utilities are required for the BIOS updates DOS The flash bootable disk must have ROM image and afudos utility Type run afudos i lt romfilename gt n p b n c Windows The flash disk must have ROM image AMIFLDRV SYS and AFUWIN EXE From a command prompt type AFUWIN i lt ROM filename gt n p b n c Linux The flash disk must have ROM image and AFULNX Type include floppy device afulnx 1 lt ROM filename n p b n c From EFI Shell The flash disk must have ROM image and AFUEFI Boot to EFI Shell with the flash disk Do a map r to obtain the file system on the disk Change the drive to the flash disk E g if the flash disk is fs0 type fs0 at the prompt 22 Intel Entry Server Board SE7221BK1 E User Guide Server Utilities Type afuefi n p b n c ROM filename n don t check ROM ID pbnc b Program Boot Block n Program NVRAM c Destroy System C
12. the processors fully seated in their sockets on the server board Are all standoffs in the proper location and not touching any components causing a potential short Are all add in PCI boards fully seated in their slots on the server board Are all jumper settings on the server board correct Are all jumper and switch settings on add in boards and peripheral devices correct To check these settings refer to the manufacturer s documentation that comes with them If applicable ensure that there are no conflicts for example two add in boards sharing the same interrupt U U U EDO OD 21 Intel Entry Server Board SE7221BK1 E User Guide Troubleshooting U D U U DL Are all peripheral devices installed correctly If the system has a hard disk drive is it properly formatted or configured Are all device drivers properly installed Are the configuration settings made in Setup correct Is the operating system properly loaded Refer to the operating system documentation Did you press the system power on off switch on the front panel to turn the server on power on light should be lit Is the system power cord properly connected to the system and plugged into a NEMA 5 15R outlet for 100 120 V or a NEMA 6 15R outlet for 200 240 V Are all integrated components from the tested components lists Check the tested memory and chassis lists as well as the supported hardware and operating system list See http support inte
13. the static charge while handling the processor 2 Avoid moving around unnecessarily Installing the Processor To install a processor follow these instructions Observe the safety and ESD precautions previously listed Please refer to matching visuals on next page A Locate the processor socket B Raise the socket handle completely C Using fingertip on back prong D Raise the socket cover E Remove the processor from package i Hold only by edges 1 Do NOT touch gold contacts F Locate the triangular shape on the pin 1 corner of the processor and line up to the alignment key G Insert the processor into the socket It should drop into the socket without any force H The CPU socket is shipped with a protective Pick and Place Cover Use both hands to remove the Plastic Cap Keep the cover to protect the socket if the processor is removed I Close the socket handle completely to lock in the processor 12 Hardware Installations and Upgrades Intel Entry Server Board SE7221BK1 E User Guide TP01331 Figure 6 Processor Install TP01332 Figure 7 Installing the Processor in the Processor Socket TP01333 Figure 8 Processor Install 13 Hardware Installations and Upgrades Intel Entry Server Board SE7221BK1 E User Guide TP01361 Figure 9 Attaching the Heat Sink to the Processor I Install the heatsink onto the processor i Use one s thumb and turn connector quarter turn to lock in The bottom of the he
14. the user is asked whether changes can be discarded If No is selected and the Enter key is pressed or if the ESC key is pressed the user is returned to where they were before ESC was pressed without affecting any existing any settings If Yes is selected and the Enter key is pressed setup is exited and the BIOS continues with POST The up arrow is used to select the previous value in a pick list or the previous options in a menu item s option list Select then press enter The down arrow is used to select the next value in a menu item s option list or a value field s pick list The selected item must then be activated by pressing the Enter key The left and right arrow keys are used to move between the major menu pages The keys have no affect if a sub menu or pick list is displayed The Tab key is used to move between fields For example Tab can be used to move from hours to minutes in the time item in the main menu The minus key on the keypad is used to change the value of the current item to the previous value This key scrolls through the values in the associated pick list without displaying the full list The plus key on the keypad is used to change the value of the current menu item to the next value This key scrolls through the values in the associated pick list without displaying the full list On 106 key Japanese keyboards the plus key has a different scan code than the plus key on the other keyboard but will have the same ef
15. years in the absence of power When the battery starts to weaken it loses voltage and the server settings stored in CMOS RAM in the RTC for example the date and time may be wrong Contact your customer service representative or dealer for a list of approved devices WARNING There is a danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the equipment manufacturer Discard used batteries according to manufacturer s instructions ADVARSEL Lithiumbatteri Eksplosionsfare ved fejlagtig handtering Udskiftning m kun ske med batteri af samme fabrikat og type Lev r det brugte batteri tilbage til leverandpren ADVARSEL Avarnine Explosionsfara vid felaktigt batteribyte Anv nd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren Kassera anvant batteri enligt fabrikantens instruktion Lithiumbatteri Eksplosjonsfare Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten Brukt batteri returneres apparatleverandgren 17 Hardware Installations and Upgrades Intel Entry Server Board SE7221BK1 E User Guide VAROITUS 18 um M L Ji an 9 Paristo voi r j ht jos se on virheellisesti asennettu Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin H vit k ytetty paristo valmistajan ohjeiden mukaisesti Observe the safety and ESD precautions at the beginning of th
16. D might be defective or the cable from the front panel to the server board might be loose LJ Have you securely plugged the server AC power cord into the power supply O Is the power supply correctly set to 110V Q Will other items plugged into the same power outlet function correctly 29 Intel Entry Server Board SE7221BK1 E User Guide Troubleshooting L U UL UL U UU U DL Some ATX power supplies have a power switch on the back of the power supply next to the fan If your system as one is it turned on Remove all add in cares and see if the system boots If successful add the cards back in one at a time with a reboot between each addition Make sure the memory DIMMs comply with the system requirements Make sure the memory DIMMs have been populated according to the system requirements Remove the memory DIMMs and re seat them Make sure the processor s comply with the system requirements Make sure the processor s have been populated according to the system requirements Remove the processor s and re seat them Make sure the chassis standoffs are installed only below mounting holes Misplaced standoffs can contact the pins on the bottom of the server board and cause a short No Characters Appear on Screen Check the following U L U U UL U LL U UL UL U U O Is the keyboard functioning Test it by turning the Num Lock function on and off to make sure the Num Lock light is functioning Is the v
17. E7221 BK1 E or a link to the software updates In addition to the server firmware and files also update any drivers used for components you have installed in your system such as video drivers network drivers and other add in cards If you are unable to resolve your server problems on your own see http support intel com support motherboards server SE7221 BK I E for assistance Resetting the System Before proceeding with in depth troubleshooting first attempt to reset your system using one of the methods below To do this Press Soft boot reset to clear the system memory and reload the operating system lt Ctrl Alt Del gt Clear system memory Restart POST and reload the operating system Reset button Cold boot reset Turn the system power off and then on This clears system memory Power off on restarts POST reloads the operating system and halts power to all peripherals Problems Following Initial System Installation Problems that occur at initial system startup are usually caused by an incorrect installation or configuration Hardware failure is a less frequent cause If the problem you are experiencing is with a specific software application see Problems With Newly Installed Application Software First Steps Checklist Is AC power available at the wall outlet Are the power supplies plugged in Check the AC cable s on the back of the chassis and at the AC source Are all cables correctly connected and secured Are
18. Intel Entry Server Board SE7221BK1 E User Guide Order Number C72987 002 Intel Entry Server Board SE7221BK1 E User Guide Disclaimer ii Disclaimer Information in this document is provided in connection with Intel products No license express or implied by estoppel or otherwise to any intellectual property rights is granted by this document Except as provided in Intel s Terms and Conditions of Sale for such products Intel assumes no liability whatsoever and Intel disclaims any express or implied warranty relating to sale and or use of Intel products including liability or warranties relating to fitness for a particular purpose merchantability or infringement of any patent copyright or other intellectual property right Intel products are not designed intended or authorized for use in any medical life saving or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur Intel may make changes to specifications and product descriptions at any time without notice Intel server boards contain a number of high density VLSI and power delivery components that need adequate airflow for cooling Intel s own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together It is the responsibility of the system integrator that chooses not to use Intel deve
19. L Electromagnetic Compatibility Notices FCC USA This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation For questions related to the EMC performance of this product contact 40 Regulatory and Compliance Information Intel Entry Server Board SE7221BK1 E User Guide Intel Corporation 5200 N E Elam Young Parkway Hillsboro OR 97124 6497 1 800 628 8686 This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the eq
20. MOS lr registry path to store result of operation only for Windows version k Program non critical block only q silent execution h print help Wait while the BIOS files are updated Do not power down the system during the BIOS update process The system will reset automatically when the BIOS update process is completed Remove the diskette from the diskette drive 1 After the BIOS updates 2 Check to make sure the BIOS version displayed during POST is the new version as the system reboots 3 Enter Setup by pressing the F2 key during boot 4 In Setup press the F9 and lt Enter gt to set the parameters back to default values 5 Re enter the values you wrote down at the beginning of this process Press F10 and lt Enter gt to exit the BIOS Setup and Save Changes 6 If you do not set the CMOS values back to defaults using the F9 key the system may function erratically amp NOTE You may encounter a CMOS Checksum error or other problem after reboot If this happens shut down the system and boot it again CMOS checksum errors require that you enter Setup check your settings save your settings and exit Setup BIOS Selection and On line Updates 24 An Online Update is the ability to update the BIOS while the server is in operation Because the system contains two copies of the BIOS you may update one while running from the other Then select the second BIOS and boot to 1t Rolling the BIOS also provides the abilit
21. NEN 16 FIgure 14 Replacing Ne Batey sie 18 Figure 15 BIOS Recovery JUMP OF aan a 25 Tables Table 1 Server Board Features sororis needs aan 2 Table 2 Configuration Jumper JE 2 aec ite testi ei ee 5 lle KAN JE BOTAN ee aies ent entend Rennen 6 Table 4 Board Power Supply Voltage Specification en 7 Tables POlBUSES mec EE 8 Table 6 BIOS Setup Keyboard Command Bar Options kE eese 21 Table 7 LEDO MIO Magee www gn 35 Table 8 Post Error Messages and Handling VV 36 Table 9 Beep CodeS re ae a cueillette 37 Table 10 Product Certification Markings 2z2u022420022200000000n0nn kk kk KK KEK nennen 40 xiii Intel Entry Server Board SE7221BK1 E User Guide Server Board Features 1 Server Board Features This chapter briefly describes the main features of Intel Entry Server Board SE7221BK1 E This chapter provides a photograph of the product a list of the server board features and diagrams showing the location of important components and connections on the server board This server board is available in three options The Intel Entry Server Board SE7221BK1 E includes Serial ATA host controller for 4 ports with support for RAID 0 1 and 10 provided It also includes dual channel Parallel ATA support and an on board Intel 82541PI Ethernet Controller The Intel Entry Server Board SE7221BK1 E LX SKU adds a second Intel 82541PI Ethernet Controller Intel Adaptive Slot technology addition
22. ades Removing DIMMs To remove a DIMM follow these steps Observe the safety and ESD precautions at the beginning of this chapter Turn off all peripheral devices connected to the server Turn off the server Remove the AC power cord from the server Remove the server s cover Gently spread the retaining clips at each end of the socket The DIMM pops out of the socket Hold the DIMM by the edges lift it away from the socket and store it in an anti static package Reinstall and reconnect any parts you removed or disconnected to reach the DIMM sockets Replace the server cover and reconnect the AC power cord SIVE S AL E de 11 Hardware Installations and Upgrades Intel Entry Server Board SE7221BK1 E User Guide Installing or Replacing the Processor Also see http support intel com support processors pentium4 sb CS 012311 htm N CAUTIONS Processor must be appropriate You may damage the server board if you install a processor that is inappropriate for your server See http support intel com support motherboards server SE7221 BK 1 E for a link to the list of compatible processors IMPORTANT Do not touch the gold contacts on the CPU or the socket ESD and handling processors Reduce the risk of electrostatic discharge ESD damage to the processor by doing the following 1 Touch the metal chassis before touching the processor or server board Keep part of your body in contact with the metal chassis to dissipate
23. ain Power Connector BB HDD LED Header System Fan 1 optional S Floppy Connector CC HSBP Header Back Panel 1 0 Connectors T IDE Connector DD Battery System Fan 2 optional U SATA 4 Connector EE Serial B Header CPU Fan optional V SATA 3 Connector CPU Socket DIMM Sockets two from left to right DIMM 1B DIMM 2B Intel Entry Server Board SE7221BK1 E User Guide Server Board Features Configuration Jumpers System Recovery and Update J1F2 1 11 CMOS CLEAR l 2 mBMC control default 2 3 Force erase PASSWORD CLEAR 5 6 Protect default 6 7 Erase RECOVERY BOOT 9 10 Normal BOOT Default 10 11 Recovery BOOT Figure 3 Configuration Jumper Location J1F2 amp NOTE Pin 1 is close to the SATA Header This view is from the CPU side insert Table 2 w Jumper J1F2 Description 00 CLEAR man control CMOS settings will be cleared on the next reset 23 Force erase _ erase Normal operation Jumper 1 2 sordo A AA and user passwords will be cleared on the next 6 7 Erase reset Normal operation Jumper 5 6 RECOVERY BOOT Normal BOOT BIOS recovery can be attempted by loading BIOS code into 10 11 Recovery BOOT flash device from a floppy Server Board Features Intel Entry Server Board SE7221BK1 E User Guide Back Panel Connectors HILL Oy TP01330 Figure 4 Back Panel Connectors The NIC LEDs at the right and left of eac
24. al fan headers and LED diagnostics The Intel Entry Server Platform SR1425BK1 E based on the Intel Server Chassis SR1400 and the Intel Entry Server Board SE7221BKI E LX SKU The Intel Server Board SE7221BK1 E with second NIC and Adaptive Slot is shown Figure 1 Intel Server Board SE7221BK1 E Server Board Features Intel Entry Server Board SE7221BK1 E User Guide Table 1 Server Board Features Feature Deseripton 2 Processors Support for an Intel Pentium 4 processor with Intel Hyper Threading Technology in an LGA775 package with an 800 MHz system bus Frequencies starting at 2 8 GHz Memory Four DDR2 SDRAM Dual Inline Memory Module DIMM sockets Support for 256MB to 4 GB Unbuffered ECC on Non ECC DDR2 400 533 system memory Support for single sided or double sided DIMMs DDR2 400 533 To run DDR2 400 MHz memory at full speed requires an Intel Pentium 4 processor with 800 MHz system bus frequency DIMMs must be ECC x8 or Non ECC x8 or x16 DDR2 unbuffered Supports Intel x4 SDDC only with x4 DIMMS Chipset Intel E7221 chipset consisting of Intel E7221 Memory Controller Hub GMCH Intel ICH6R I O Controller Hub Intel PXH PCI X Hub National Semiconductor PC87431M mini Baseboard Management Controller I O Control National Semiconductor PC87427 Super I O controller chip Peripheral Interfaces Two external USB 2 0 ports on the back panel with an additional internal header which pro
25. ard input is incorrect a marginal power supply or other random component failures LJ If you suspect that a transient voltage spike power outage or brownout might have occurred reload the software and try running it again Symptoms of voltage spikes include a flickering video display unexpected system reboots and the system not responding to user commands 33 Intel Entry Server Board SE7221BK1 E User Guide Troubleshooting amp NOTE Random errors in data files If you are getting random errors in your data files they may be getting corrupted by voltage spikes on your power line If you are experiencing any of the above symptoms that might indicate voltage spikes on the power line you may want to install a surge suppressor between the power outlet and the system power cord Devices Are Not Recognized Under Device Manager Windows Operating System The Windows operating systems do not include all of the drivers for the Intel chipsets onboard NICs and other components See http support intel com or a link to the current drivers and chipset files Hard Drive s Are Not Recognized Check the following Q Make sure the drive is not disabled in the BIOS Setup Q Make sure the drive is connected correctly and that is plugged into the power supply Q Make sure the drive is compatible See http www support intel com support motherboards server SE7221BKI E for a link to the tested drives Q Make sure you have not exc
26. asis o en el tablero puede haber piezas cortantes o punzantes Por ello se recomienda precauci n y el uso de guantes protectores INSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones Apague todos los dispositivos perif ricos conectados al sistema Apague el sistema presionando el interruptor encendido apagado Desconecte todos los cables de alimentaci n CA del sistema o de las tomas de corriente alterna Identifique y desconecte todos los cables enchufados a los conectores E S o a los puertos situados en la parte posterior del sistema Cuando manipule los componentes es importante protegerse contra la descarga electrost tica ESD Puede hacerlo si utiliza una mufiequera antiest tica sujetada a la toma de tierra del chasis o a cualquier tipo de superficie de metal sin pintar No ponga en marcha el sistema si se han extra do las tapas del chasis AVVERTENZA Italiano il 2 3 4 6 PASSI DI SICUREZZA Qualora si rimuovano le coperture del telaio per accedere all interno del sistema seguire i seguenti passi Spegnere tutti i dispositivi periferici collegati al sistema Spegnere il sistema usando il pulsante spento acceso dell interruttore del sistema Togliere tutte le spine dei cavi del sistema dalle prese elettriche Identificare e sconnettere tutti i cavi attaccati ai collegamenti I O od alle prese installate sul retro
27. at sink has thermal interface material TIM already applied Be careful not to damage the thermal interface material Platform models must use an active heat sink with fan Note SR1425BK1 E models come with a custom copper lu passive heat sink Solid areas go on the left and the right not the front and back of the processor If TIM is covered by a protective sheet remove the sheet TP01359 Figure 10 Heat Sink 14 Intel Entry Server Board SE7221BK1 E User Guide Hardware Installations and Upgrades Removing the Processor To remove the processor follow these instructions 1 2 ee Observe the safety and ESD precautions previously listed Use a flat blade screwdriver to turn each connector 1 4 turn so it pops out of the server board Lift firmly since TIM may create some stickiness between heat sink and processor Lift the heat sink from the processor Lift the processor lever Remove the processor Hold it by the edges only Return the processor cover to the processor and the PnP to the socket while not in use TP01360 Figure 11 Heat Sink Snap 15 Hardware Installations and Upgrades Intel Entry Server Board SE7221BK1 E User Guide Installing a PCI PCI X or PCI Express Card Peripherals and add n cards are not included in your system and must be purchased separately The process for adding PCI adapters is dependant upon the chassis configuration pedestal or rack mount TP01362 Figu
28. ave Hard Disk Error Pause 151 Primary Master Drive ATAPI Incompatible Pause 152 Primary Slave Drive ATAPI Incompatible Pause Troubleshooting Intel Entry Server Board SE7221BK1 E User Guide Error Code Error Message Response 153 Secondary Master Drive ATAPI Incompatible Pause 154 Secondary Slave Drive ATAPI Incompatible Pause 8100 Processor Failed BIST Warning 8110 Processor Internal Error IERR Warning 8120 Processor Thermal Trip Error Warning 8160 Processor Unable to Apply BIOS Update Pause 8170 Processor L2 Cache Failed Pause 8180 BIOS does not support current stepping for Processor Pause 8190 Watchdog Timer failed on last boot Warning 8191 12 1 Core to bus ratio Processor Cache disabled Pause 8192 L2 Cache size mismatch Pause 8193 CPUID Processor Stepping are different Pause 8194 CPUID Processor Family are different Pause 8195 Front Side Bus Speed ismatch System Halted Pause 8197 CPU Speed mismatch Pause 8300 Baseboard Management Controller failed to function Pause 8301 Front Panel Controller failed to Function Pause 84F2 Server Management Interface Failed Pause 84F3 BMC in Update Mode Pause 84F4 Sensor Data Record Empty Pause 84FF System Event Log Full Warning BIOS POST Beep Codes The table below lists the POST error beep codes Prior to system video initialization the BIOS uses these beep codes to inform users of error conditions The beep code occurs only when a critical error occurs or when the BIOS fails to boot
29. bnehmen um an das Systeminnere zu gelangen sollten Sie folgende Schritte beachten 1 Schalten Sie alle an Ihr System angeschlossenen Peripherieger te aus Schalten Sie das System mit dem Hauptschalter aus Ziehen Sie den Stromanschlu stecker Ihres Systems aus der Steckdose Auf der R ckseite des Systems beschriften und ziehen Sie alle Anschlu kabel von den I O Anschl ssen oder Ports ab Tragen Sie ein geerdetes Antistatik Gelenkband um elektrostatische Ladungen ESD ber blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden Schalten Sie das System niemals ohne ordnungsgem montiertes Geh use ein vii Preface Intel Entry Server Board SE7221BK1 E User Guide Viii BAREH TMS AI o KWE TAS RK RH 2 Resource CD JY Ik http support intel com support motherboards server sb CS 010770 htm ER Intel Server Boards and Server Chassis Safety Information Intel Jk ae EA SH alae ZE AY o Consignes de securite Lisez attention toutes les consignes de s curit et les mises en garde indiqu es dans ce document avant de suivre toute instruction Consultez Intel Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez vous sur le site http support intel com support motherboards server sb CS 010770 htm CONSIGNES DE S CURIT Lorsque vous ouvrez le bo tier pour acc der l int rieur du syst me suivez les consignes suivantes 1 Mettez hors tensio
30. ccurately configure memory settings for optimum performance If non SPD memory is installed the BIOS will attempt to correctly configure the memory settings but performance and reliability may be impacted or the DIMMs may not function under the determined frequency For a complete list of supported memory DIMMs see the links under http support intel com support motherboards server SE7221 BK1 E Power Supply The Power Supply must be a minimum of 450 Watts Suggested connectors include 2x12 for Main Power Connector 2x2 yellow black wires in a 2x4 connector for 12v auxiliary power to Processor Split 12v rails to SATA Standard IDE 4 wire connector Table 4 Board Power Supply Voltage Specification PARAM TOLERANCE MIN NOM MAX UNITS 3 3V 5 5 3 14 3 30 3 46 Vrms 5V 5 5 4 75 5 00 5 25 Vrms 12V 5 5 11 40 12 00 12 60 Vrms 12V 10 10 11 40 12 00 13 08 Vims 5VSB 5 5 4 75 5 00 5 25 V ms Server Board Features Intel Entry Server Board SE7221BK1 E User Guide PCI Buses There are four independent PCI bus segments dependent on model The PCI buses comply with the PCI Local Bus Specification Rev 2 3 P32 A supports Slot 1 and NIC 1 on a 32 bit 33 MHz bus routed from the ICH6R P32 B supports the optional second NIC routed through the PXH P64 C supports two PCI X slots routed through the PXH In some models PC64 C will instead support the riser slot if used for PCI X
31. del sistema Qualora si tocchino i componenti proteggersi dallo scarico elettrostatico SES portando un cinghia anti statica da polso che amp attaccata alla presa a terra del telaio del sistema qualsiasi superficie non dipinta Non far operare il sistema quando il telaio senza le coperture Se il sistema e stato a lungo in funzione il microprocessore e il dissipatore di calore potrebbero essere surriscaldati Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio E consigliabile l uso di guanti di protezione ix Intel Entry Server Board SE7221BK1 E User Guide lt THIS PAGE INTENTIONALLY LEFT BLANK gt Contents Intel Entry Server Board SE7221BK1 E User Guide Contents 1 Server Board FSalUF GS an esse sean cn 1 Connector and Component Locations u uu002u000an0nann0nnnunnnnnnnnunnnnunnnnnnanunnnnnnn nun 4 Configuration JJuUmpers usce bear canaria corriera AA AA Raw E WAA HAAA Eu AWAN HAAA DR SR AHAA AN HAAA AW WAA UU WA WW WR 5 System Recovery and Update uusunnaanuonannnnnnnannnnnnnnunnnnnnnnnnnnunnnnnnnnnunnunnnnnnnnunnnenn 5 BACK uere e g east masse Naaa Rainaa 6 Hardware RequirementisS 202000200000000000n0nanunanunanunnnunnnnnnnnnnunnnunnnunnnunnnnnnnnnnnnnnnn nun AA WAAR 7 2 Hardware Installations and Upgrades 9 PPP 9 Tools and Supplies Needed
32. driver 1 bit and 2 bit Flat head screwdriver Needle nosed pliers Antistatic wrist strap and conductive foam pad recommended Gloves to avoid sharp edges recommended Hardware Installations and Upgrades Intel Entry Server Board SE7221BK1 E User Guide Installing and Removing Memory DIMM 1A DIMM 2A DIMM 1B DIMM 2B TP01327 Figure 5 DIMM Install Installing DIMMs Q N N OS 10 11 10 Note You must use DDR2 DIMMs Observe the safety and ESD precautions at the beginning of this user guide Turn off all peripheral devices connected to the server Turn off the server Disconnect the AC power cord Remove the chassis cover and locate the DIMM sockets Make sure the clips at either end of the DIMM socket s are pushed outward to the open position Holding the DIMM by the edges remove it from its anti static package Position the DIMM above the socket Align the small notch in the bottom edge of the DIMM with the keys in the socket see inset in Figure Insert the bottom edge of the DIMM into the socket When the DIMM is inserted push down on the top edge of the DIMM until the retaining clips snap into place Make sure the clips are firmly in place Replace the server s cover and reconnect the AC power cord Note Populate in this order 1A 1B 2A 2B Match DIMMs in the same Channel Intel Entry Server Board SE7221BK1 E User Guide Hardware Installations and Upgr
33. e following safety requirements UL60950 CSA 60950 USA Canada EN60950 Europe EC60950 International CB Certificate amp Report IEC60950 report to include all country national deviations GOST R 50377 92 Listed on one System License Russia Belarus License Listed on System License Belarus CE Low Voltage Directive 73 23 EEE Europe IRAM Certification Argentina Product EMC Compliance Class A Compliance Note Legally the product is required to comply with Class A emission requirements as it is intended for a commercial type market place Intel targets 10db margin to Class A Limits The server board SE7221 BKI E has been has been tested and verified to comply with the following electromagnetic compatibility EMC regulations when installed a compatible Intel host system For information on compatible host system s refer to Intel s Server Builder Web site or contact your local Intel representative FCC ICES 003 Emissions USA Canada Verification CISPR 22 Emissions International EN55022 Emissions Europe ENS5024 Immunity Europe CE EMC Directive 89 336 EEC Europe AS NZS 3548 Emissions Australia New Zealand BSMI CNS13438 Emissions Taiwan GOST R 29216 91 Emissions Listed on one System License Russia GOST R 50628 95 Immunity Listed on one System License Russia Belarus License Listed on one System License Belarus RRL MIC Notice
34. eeded the power budget for the server See http www support intel com support motherboards server SE7221 BK 1 E for a link to software to check your power budget LI If using IDE drives verify that the master slave settings are set correctly See your drive documentation for details on setting the master slave settings Q If using a RAID configuration with SATA drives make sure the RAID is setup correctly Bootable CD ROM Is Not Detected Check the following U 34 Make sure the BIOS is configured to allow the CD ROM to be the first bootable device Troubleshooting Intel Entry Server Board SE7221BK1 E User Guide Error Handling and Reporting LED Information The Intel Server Board SE7221BK1 E includes LEDs that can aid in troubleshooting your system A table of these LEDs with a description of their use is listed below LED Name ID System fault IDE activity Memory fault 1 4 POST code 1 4 LSB bit1 bit2 MSB Fan Pack Fault CPU Fan Fault CPU Fault 5v Standby Power LED Function Aid in server identification from the back panel Visible fault warning Front panel Identify failing memory module Display boot 80 POST code Warn on fan failure Identify fan failure Identify processor failure Identify 5v standby power on state Identify the power state of the system Location Front Panel and board rear Front panel and board rear Front panel and board left side DIMM
35. eeeeseeeeseesenseeenseeenseenenseeenseseaseeneneens 25 Clearing the Password e 26 2 AE ekla CMOS 2 26 4 TFOUDIESNOOUNG na se ee sa ee 27 Dan l RP 27 Problems Following Initial System Installation 27 First Steps CNOCKlI e 27 Hardware Diagnostic Testing kk kk eee kak kk kk rene nennen nnne KAKA KAKA KA KAK KWA KA WAA 28 Verifying Proper Operation of Key System Lights 29 Confirming Loading of the Operating System lk kk kk kk kk kk AJ 29 Specific Problems and Corrective Actions u 220020002u00nan0nanunnnnunnnnnnnnunnnnnnnnun nun 29 Power Eight DOGS Not LIQ iii en nn ee 29 No Characters Appear on Screen uusuauusuan0nanunnnnunnnnnnunununnnnnnunnnnnnannnnnnnnununnnnnnnn 30 Xl Contents Intel Entry Server Board SE7221BK1 E User Guide Characters Are Distorted or Incorrect 20 22000220002an0nan0nnnnnnunnnnnnannnnnnn 30 System Cooling Fans Do Not Rotate Properly 31 Diskette Drive Activity Light Does Not Light 31 CD ROM Drive or DVD ROM Drive Activity Light Does Not Light 31 Cannot Connect TO a Server iniciaran a 32
36. end front of board Rear of board Front center board Front center board 1 behind processor socket Front left board Front Panel Table 7 LED Information Color Blue Green or Amber Green Amber Each LED can be Off Green Amber Red Amber Amber Amber Amber Green Correction Press ID LED button or user Server Management software to turn off the LED On No Fault Green Blink degraded Amber critical error or non recoverable Amber blink non critical Blinking Activity No action required On Fault See the POST code table On Fault On Fault On Fault On 5v standby power on Off Power is off off or S5 On Power on or SO Slow Blink Low power state S1 S3 35 Intel Entry Server Board SE7221BK1 E User Guide Troubleshooting BIOS Event Log 36 The BIOS will output the current boot progress codes on the video screen Progress codes are 32 bit quantities plus optional data The 32 bit numbers include Class Subclass and Operation information Class and Subclass point to the type of the hardware that is being initialized where as the Operation field represents the specific initialization activity Based upon the data bit availability to display Progress Code a progress code can be customized to fit the data width The higher the data bit higher the granularity of information which could send on the progress port The progress code
37. ent failure Check the following Q Is the power on light lit If not see Power Light Does Not Light If your system has LED lights for the fans is one or more of these LEDs lit Are any other front panel LEDs lit U U LU Have any of the fan motors stopped Use the server management subsystem to check the fan status Have your fans speeded up in response to an overheating situation Have your fans speeded up in response to a fan that has failed Are the fan power connectors properly connected to the server board U U U LL Is the cable from the front panel board connected to the both the front panel board and to the server board L Are the power supply cables properly connected to the server board O Are there any shorted wires caused by pinched cables or have power connector plugs been forced into power connector sockets the wrong way Diskette Drive Activity Light Does Not Light Check the following LI Is the diskette drive s power and signal cables properly installed Are all relevant switches and jumpers on the diskette drive set correctly Is the diskette drive properly configured U U LU Is the diskette drive activity light always on If so the signal cable may be plugged in 1ncorrectly If you are using the onboard diskette controller use the BIOS setup to make sure that Onboard Floppy is set to Enabled If you are using an add in diskette controller make sure that Onboard Floppy
38. fect Pressing F9 causes the following to appear Load Setup Defaults OK Cancel If OK is selected and the Enter key is pressed all setup fields are set to their default values If Cancel is selected and the Enter key is pressed or if the ESC key is pressed the user is returned to where they were before F9 was pressed without affecting any existing field values Pressing F7 causes the following message to appear Discard Changes OK Cancel If OK is selected and the Enter key is pressed all changes are not saved and setup is exited If Cancel is selected and the Enter key is pressed or the ESC key is pressed the user is returned to where they were before F7 was pressed without affecting any existing values 21 Key F10 Intel Entry Server Board SE7221BK1 E User Guide Server Utilities Option Description Save Changes and Pressing F10 causes the following message to appear Exit Save configuration changes and exit setup OK Cancel If OK is selected and the Enter key is pressed all changes are saved and setup is exited If Cancel is selected and the Enter key is pressed or the ESC key is pressed the user is returned to where they were before F10 was pressed without affecting any existing values Upgrading the BIOS The upgrade utility allows you to upgrade the BIOS in flash memory The code and data n the upgrade file include the following On board BIOS ATA 100 RAID BIOS and
39. formity This product has been tested in accordance too and complies with the Low Voltage Directive 73 23 EEC and EMC Directive 89 336 EEC The product has been marked with the CE Mark to illustrate its compliance 4 Intel Entry Server Board SE7221BK1 E User Guide Regulatory and Compliance Information Taiwan Declaration of Conformity BSMI E eH 16 ze ARAB A Em LEA RE TETERA gt ARI T EEE WE Ki E AR The BSMI Certification Marking and EMC warning is located on the outside rear area of the product Korean Compliance RRL gt r E ddr eu MIC J 5 SIEHE nei ya Qe BR 5 MEA MER English translation of the notice above 1 Type of Equipment Model Name On License and Product 2 Certification No On RRL certificate Obtain certificate from local Intel representative 3 Name of Certification Recipient Intel Corporation 4 Date of Manufacturer Refer to date code on product 5 Manufacturer Nation Intel Corporation Refer to country of origin marked on product 42 Getting Help Intel Entry Server Board SE7221BK1 E User Guide Getting Help World Wide Web http support intel com support motherboards server SE7221BK1 E Telephone All calls are billed US 25 00 per incident levied in local currency at the applicable credit card exchange rate plus applicable taxes Intel reserves the right to change the pricing for telephone support at any time without notice Before calling fill out an Intel
40. front of the system LJ Unplug the AC power cord s from the server Problems With Newly Installed Application Software Problems that occur when you run new application software are usually related to the software not the server hardware Faulty equipment is unlikely especially if other software runs correctly Check the following LJ Make sure the system meets the minimum hardware requirements for the software See the software documentation Q Make sure the software is properly installed and configured for the system See the software documentation Q Use only an authorized copy Unauthorized copies often do not work Q If you are running the software from a diskette CD ROM or DVD ROM try a different diskette Make sure the correct device drivers installed If the problems persist contact the software vendor s customer service representative Problems With Application Software That Ran Correctly Earlier Problems that occur after the system hardware and software have been running correctly sometimes indicate equipment failure However they can also be caused by file corruption or changes to the software configuration Check the following Q If you are running the software from a diskette CD ROM or DVD ROM try a different diskette Uninstall and reinstall the software Make sure all necessary files are installed LI If the problems are intermittent there may be a loose cable dirt in the keyboard if keybo
41. h NIC provide the following information Table 3 NIC LEDs No network connection Left LED Solid Green Network connection in place _ Blinking Green Transmit receive activity NIC1 Gigabit 10 Mbps connection if left LED is on or blinking Right LED Solid Green 100 Mbps connection Solid Amber 1000 Mbps connection No network connection Left LED Solid Green Network connection in place Blinking Green Transmit receive activity NIC 2 Gigabit 100 Mbps connection Solid Amber 1000 Mbps connection Optional 10 Mbps connection if left LED is on or blinking Right LED Solid Green Intel Entry Server Board SE7221BK1 E User Guide Server Board Features Hardware Requirements To avoid integration difficulties and possible board damage your system must meet the requirements outlined below For a list of qualified components see the links under http www support intel com support motherboards server SE7221 BK1 E Processor One 2 8 GHz or greater Intel9 Pentium 4 processor in an LGA775 package for an 800 MHz system bus For a complete list of supported processors see the links under http www support intel com support motherboards server SE7221 BK1 E Memory One to four DIMMs Unbuffered DDR2 400 533 MHz ECC or non ECC ECC will be disabled if any non ECC DIMMs are used 256MB to IGB DIMMs Should support Serial Presence Detect SPD data structure This allows the BIOS to read the SPD data and program the chipset to a
42. hether you are using this guide or any other resource as a reference pay close attention to the safety instructions You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region s in which the product is sold Emissions Disclaimer To ensure EMC compliance with your local regional rules and regulations the final configuration of your end system product may require additional EMC compliance testing For more information please contact your local Intel Representative See the Regulatory and Integration Information for product safety compliance and EMC regulatory compliance information This is an FCC Class A device Integration of it into a Class B chass s does not result n a Class B device Intended Uses This product was evaluated as Information Technology Equipment ITE which may be installed n offices schools computer rooms and similar commercial type locations The suitability of this product for other product categories and environments such as medical industrial telecommunications NEBS residential alarm systems test equipment etc other than an ITE application may require furthe
43. ideo monitor plugged in and turned on If you are using a switch box is it switched to the correct system Are the brightness and contrast controls on the video monitor properly adjusted Is the video monitor signal cable properly installed Does this video monitor work correctly if plugged into a different system Is the onboard video controller enabled in the BIOS Remove all add in cares and see if the video returns If successful add the cards back in one at a time with a reboot between each addition Make sure the memory DIMMs comply with the system requirements Make sure the memory DIMMS have been populated according to the system requirements Remove the memory DIMMs and re seat them Make sure the processor s comply with the system requirements Make sure the processor s have been populated according to the system requirements Remove the processor s and re seat them Characters Are Distorted or Incorrect 30 Check the following U U Are the brightness and contrast controls properly adjusted on the video monitor See the manufacturer s documentation Are the video monitor s s gnal and power cables properly installed Does this video monitor work correctly if plugged into a different system Troubleshooting Intel Entry Server Board SE7221BK1 E User Guide System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly it is an indication of possible system compon
44. iguration it tests for the presence of each mass storage device installed in the system As each device is checked its activity light should turn on briefly Check for the following Q Does the diskette drive activity light turn on briefly If not see Diskette Drive Activity Light Does Not Light Q If system LEDs are illuminated see Error Handling and Reporting in section on Troubleshooting Confirming Loading of the Operating System Once the system boots up the operating system prompt appears on the screen The prompt varies according to the operating system If the operating system prompt does not appear see No Characters Appear on Screen Specific Problems and Corrective Actions This section provides possible solutions for these specific problems Power light does not light No characters appear on screen Characters on the screen appear distorted or incorrect System cooling fans do not rotate Diskette drive activity light does not light Hard disk drive activity light does not light CD ROM drive activity light does not light There are problems with application software The bootable CD ROM is not detected Try the solutions below in the order given If you cannot correct the problem contact your service representative or authorized dealer for help Power Light Does Not Light Check the following Q Did you press the power on button Q Is the system operating normally If so the power LE
45. is book Turn off all peripheral devices connected to the server Turn off the server Disconnect the AC power cord from the server Remove the server s cover and locate the battery It stands upright next to the processor Insert the tip of a small flat bladed screwdriver or an equivalent under the tab in the plastic retainer Gently push down on the screwdriver to lift the battery Remove the battery from its socket Dispose of the battery according to local ordinance Remove the new lithium battery from its package and being careful to observe the correct polarity insert it in the battery socket Close the chassis 10 Run the Setup to restore the configuration settings to the RTC I _ o DO TP01328 Figure 14 Replacing the Battery Intel Entry Server Board SE7221BK1 E User Guide Server Utilities 3 Server Utilities BIOS Setup The BIOS Setup utility is provided to perform system configuration changes and to display current settings and environment information The BIOS Setup utility stores configuration settings in the system s non volatile memory Changes affected by the BIOS Setup will not take effect until the system is rebooted The BIOS Setup Utility can be accessed when prompted during POST by using the F2 key Localization The BIOS Setup utility uses the Unicode standard and is capable of displaying setup forms
46. l com support motherboards server SE7221BK1 E for links to the tested component lists Hardware Diagnostic Testing A 28 This section provides a more detailed approach to identifying a hardware problem and locating its SOUICC CAUTION Turn off devices before disconnecting cables Before disconnecting any peripheral cables from the system turn off the system and any external peripheral devices Failure to do so can cause permanent damage to the system and or the peripheral devices Turn off the system and all external peripheral devices Disconnect each device from the system except for the keyboard and the video monitor Make sure the system power cord is plugged into a properly grounded AC outlet Make sure your video display monitor and keyboard are correctly connected to the system Turn on the video monitor Set its brightness and contrast controls to at least two thirds of their maximum ranges see the documentation supplied with your video display monitor If the operating system normally loads from the hard disk drive make sure there is no diskette in drive A and no CD ROM disk in the CD ROM drive If the power LED does light attempt to boot from a floppy diskette or from a CD ROM disk Turn on the system If the power LED does not light see Power Light Does Not Light Troubleshooting Intel Entry Server Board SE7221BK1 E User Guide Verifying Proper Operation of Key System Lights As POST determines the system conf
47. latory Compliance Markings eese 40 Electromagnetic Compatibility Notices e eeees eee eeeee eere eene nennen 40 EEE USA j eU 40 Industry Canada ICES 003 ana en 41 Europe CE Declaration of Conformity u 2202200022000an0nan0nnnnunanunnannnnn 41 Taiwan Declaration of Conformity BSMI cessus 42 Korean Compliance ARL s xi l kiy aki ceux ue aaa Dh ens e Dav Dog Eau Rad 42 COCO ar jo mE E 43 Intel Server Issue Report Form uuu0u00220an00000nnannnunnnnnnnnnnunnnnnnnnnunnnnnnannnnn 45 xli Intel Entry Server Board SE7221BK1 E User Guide Contents Figures Figure 1 Intel Server Board SE7221BK1 E M 4K4K K K 4 kk kk kk kek k kk name nennen nnne nnns 1 Figure 2 Intel Entry Server Board SE7221BK1 E Connections 4 Figure 3 Configuration Jumper Location J1F2 RL 5 Figure 4 Back Panel Connectors ii k kk k kk k kk k kk KK A KK nnns 6 Bul NR S DIMMINS IAE dire een ds te ns a tn etc 10 FOUS 6 PIOCSSSOH N SLA E ee een 13 Figure 7 Installing the Processor in the Processor Socket VU 13 Fig re 8 Processor INstall psss ii sede r me 13 Figure 9 Attaching the Heat Sink to the Processor 14 FOUS TOACA COT L ni dob am ceca 14 Figure Til Heat SNK ST aimara ia 15 Figure 12 Addim AISE acordo here ee d aa nee Rte 16 Foure T Ad NO ard
48. ld boards only by their edges After removing a board from its protective wrapper or from the server place the board component side up on a grounded static free surface Use a conductive foam pad if available not the board wrapper Do not slide board over any surface Installing or Removing Jumpers A jumper is a small plastic encased conductor that slips over two jumper pins Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers If your jumpers do not have such a tab take care when using needle nosed pliers to remove or install a jumper grip the narrow sides of the jumper with the pliers never the wide sides Gripping the wide sides can damage the contacts inside the jumper causing intermittent problems with the function controlled by that jumper Take care to grip with but not squeeze the pliers or other tool you use to remove a Jumper or you may bend or break the pins on the board Intel Entry Server Board SE7221BK1 E User Guide Preface Safety Cautions Read all caution and safety statements in this document before performing any of the instructions See also ntel Server Boards and Server Chassis Safety Information on the Resource CD and or at http support intel com support motherboards server sb CS 010770 htm 6 A microprocessor and heat sink may be hot if the system has been running Also there may be sharp pins and edges on some board and chassis pa
49. ll find a list of the server board features photos of the product and product diagrams to help you identify components and their locations Chapter 2 provides instructions on adding and replacing components Use this chapter for step by step instructions and diagrams for installing or replacing components such as the memory processor the battery and other components Chapter 3 provides instructions on using the utilities that are shipped with the board or that may be required to update the system This includes how to navigate through the BIOS Setup screens how to perform a BIOS update and how to reset the password or CMOS Information about the specific BIOS settings and screens is available in the Technical Product Specification See http support intel com support motherboards server se7221bk1 e spec htm for a link to the Technical Product Specification Chapter 4 provides troubleshooting information In this chapter you will find BIOS error messages and POST code messages You will also find suggestions for performing troubleshooting activities to identify the source of a problem Product Accessories This server board is compatible with the following Intel Server Chassis Intel Entry Server Platform SR1425BK1 E Integrated 1U chassis and board Intel Entry Server Chassis SC5250 E You may need or want to purchase one or more of the following accessory items for your server Processor memory DIMMs hard drive floppy dri
50. loped server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non operating limits Intel Intel Pentium and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Other names and brands may be claimed as the property of others Copyright 2004 Intel Corporation All Rights Reserved Intel Entry Server Board SE7221BK1 E User Guide Preface Preface About This Manual Thank you for purchasing and using the Intel Entry Server Board SE7221BK1 E This manual is written for system technicians who are responsible for troubleshooting upgrading and repairing this server board This document provides a brief overview of the features of the board chassis a list of accessories or other components you may need troubleshooting information and instructions on how to add and replace components on the Intel Entry Server Board SE7221BK1 E For the latest version of th s manual refer to http support intel com support motherboards server SE7221BK1 E Manual Organization Chapter 1 provides a brief overview of the Intel Entry Server Board SE7221BK1 E In this chapter you wi
51. mware Version DIMM2A MB Chassis Model DIMM2A Vendor part number O Intel SC5250 E O Intel SR1425BK1 E O Other Vendor Model 45 Intel Entry Server Board SE7221BK1 E User Guide Operating System Information Operating System Version Service Pack Peripheral Information Intel Server Issue Report Form Check each box below that is used and provide the requested information Driver Revision Peripheral Card Or Peripheral Description PCI Slot 1 PCI Slot 3 PCI Slot 4 PCI Slot 5 Video O On Board Video NIC O On Board NIC1 O On Board NIC2 1 0 Gb 32 33 64 100 64 100 adaptive or PCI Express De mM Hard Drive Information g SATA of drives installed Make Model Firmware Revision n IDE of drives installed Make Model Firmware Revision n SCSI of drives installed Make Model Firmware Revision 46 IRQ I O Base Address FW Rev Intel Server Issue Report Form Intel Entry Server Board SE7221BK1 E User Guide Complete Problem Description In the space below provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found Please also include any details on troubleshooting already done 47
52. n tous les p riph riques connect s au syst me 2 Mettez le syst me hors tension en mettant l interrupteur g n ral en position OFF bouton poussoir 3 D branchez tous les cordons d alimentation c a du syst me et des prises murales 4 Identifiez et d branchez tous les c bles reli s aux connecteurs d E S ou aux acc s derri re le syst me 5 Pour pr venir les d charges lectrostatiques lorsque vous touchez aux composants portez une bande antistatique pour poignet et reliez la la masse du syst me toute surface m tallique non peinte du boitier 6 Ne faites pas fonctionner le syst me tandis que le bo tier est ouvert Le microprocesseur et le dissipateur de chaleur peuvent tre chauds si le systeme a t sous tension Faites galement attention aux broches aigu s des cartes et aux bords tranchants du capot Nous vous recommandons l usage de gants de protection Intel Entry Server Board SE7221BK1 E User Guide Preface Instrucciones de seguridad importantes Lea todas las declaraciones de seguridad y precauci n de este documento antes de realizar cualquiera de las instrucciones Vea Intel Server Boards and Server Chassis Safety Information en el CD Resource y o en http support intel com support motherboards server sb C S 010770 htm 6 Si el sistema ha estado en funcionamiento el microprocesador y el disipador de calor pueden estar a n calientes Tambi n conviene tener en cuenta que en el ch
53. nnect the AC power 2 Open the server chassis 3 Move the jumper from pins five and six to the Clear Password position covering pins six and seven 4 Reconnect the AC power power up the system 5 Power down the system and disconnect the AC power 6 Return the Password Clear jumper to the spare location covering pins five and six 7 Close the server chassis Clearing the CMOS If you are not able to access the BIOS setup screens the CMOS Clear jumper will need to be used to reset the configuration RAM The CMOS Clear jumper is located on jumper block J1F2 26 l 2 3 p pus Power down the system and disconnect the AC power Open the server Move the jumper from pins one and two to the Clear CMOS position covering pins two and three Reconnect the AC power power up the system When the system begins beeping power it down and disconnect the AC power Return the CMOS Clear jumper to the original location covering pins one and two Close the server chassis reconnect the AC power and power up the system Troubleshooting Intel Entry Server Board SE7221BK1 E User Guide 4 Troubleshooting This chapter helps you identify and solve problems that might occur while you are using the system For any issue first ensure you are using the latest firmware and files Firmware upgrades include updates for the BIOS and the mini baseboard management controller mBMC See http support intel com support motherboards server S
54. ocessor fan Intel Entry Server Board SE7221BK1 E User Guide Server Board Features Intel AMI BIOS with support for Advanced Configuration and Power Interface ACPI 8 megabit symmetrical flash memory Support for SMBIOS Power Management Support for ACPI Support for SO S1 S4 and S5 Wake on USB PCI RS 232 PS 2 LAN and front panel Server Management Intel Server Management support via National Semiconductor mini Baseboard Management Controller mBMC Server Board Features Intel Entry Server Board SE7221BK1 E User Guide Connector and Component Locations O W m The connections you make depend on the chassis and the components you are installing A B D EF G H E Ay EE DD CC K BB AA L e oo Doo Y EB X OIOI img W SE A V UT S H QP O N M L TP01326 Figure 2 Intel Entry Server Board SE7221BK1 E Connections Chassis Intrusion Header M DIMM Sockets two from left to W 34 pin Front Panel Connector right DIMM 1A DIMM 2A PCI Slot N Front USB Header optional X Serial ATA SATA 2 Connector PCI X 100 SLOT O System Fan Headers for Intel Y SATA 1 Connector Server Board SR1425BK1 E PCI X 100 SLOT P System Fan 4 Z BIOS Control Jumper PCI Express or Riser Connector Q System Fan 3 optional AA BIOS Select Jumper Slot 12v CPU Power R M
55. r evaluation EMC Testing Before computer integration make sure that the chassis power supply and other modules have passed EMC testing using a server board with a microprocessor from the same family or higher and operating at the same or higher speed as the microprocessor used on this server board A WARNING System power on off The power button DOES NOT turn off the system AC power To remove power from system you must unplug the AC power cord from the wall outlet Make sure the AC power cord is unplugged before you open the chass s add or remove any components Hazardous conditions devices and cables Hazardous electrical conditions may be present on power telephone and communication cables Turn off the server and disconnect the power cord telecommunications systems networks and modems attached to the server before opening it Otherwise personal injury or equipment damage can result Electrostatic Discharge ESD and ESD Protection ESD can damage disk drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist Preface Vi Intel Entry Server Board SE7221BK1 E User Guide strap attached to chassis ground any unpainted metal surface on your server when handling parts ESD and Handling Boards Always handle boards carefully They can be extremely sensitive to ESD Ho
56. re 12 Add in Riser TPO1365 Figure 13 Add in Card Pedestal chassis add in procedure In the pedestal configuration the PCI slots support add in cards with full height brackets 1 Remove the screw that fastens the PCI bracket to the rear of the chassis Retain the screw Insert the PCI card into the PCI slot Keep the add in card level during insertion Tilting it during installation may damage the card or the slot 3 Use the screw removed in step 1 to secure the PCI card to the chassis 16 Intel Entry Server Board SE7221BK1 E User Guide Hardware Installations and Upgrades Rack mount chassis add in procedure The PCI Riser Bracket Assembly fits tightly against power connections on the server board Be very carful not to pinch or damage the electrical connections when installing and removing the Bracket Assembly 1 Remove the riser bracket 2 Attach the riser connector to the bracket with the 2 screws accompanying the chassis 2 Insert the add in PCI card into the riser connector Tilting card while forcing into riser will damage the add in card 4 Use the 3 screw to connect the add in card s bracket to the main bracket assembly 5 Install the bracket assembly aligning the I O edge with the slots in the back of the chassis and the riser card into the server board adaptive slot 6 Push down firmly but carefully Replacing the Backup Battery The lithium battery on the server board powers the RTC for up to ten
57. rts Contact should be made with care Consider wearing protective gloves 2 3 4 SAFETY STEPS Whenever you remove the chassis covers to access the inside of the system follow these steps 1 Turn off all peripheral devices connected to the system Turn off the system by pressing the power button Unplug all AC power cords from the system or from wall outlets Label and disconnect all cables connected to I O connectors or ports on the back of the system Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis ground of the system any unpainted metal surface when handling components Do not operate the system with the chassis covers removed Wichtige Sicherheitshinweise Lesen Sie zun chst s mtliche Warn und Sicherheitshinweise in diesem Dokument bevor Sie eine der Anweisungen ausf hren Beachten Sie hierzu auch die Sicherheitshinweise zu Intel Serverplatinen und Servergeh usen auf der Ressourcen CD oder unter http support intel com support motherboards server sb CS 010770 htm 6 Der Mikroprozessor und der K hler sind m glicherweise erhitzt wenn das System in Betrieb ist Au erdem k nnen einige Platinen und Geh useteile scharfe Spitzen und Kanten aufweisen Arbeiten an Platinen und Geh use sollten vorsichtig ausgef hrt werden Sie sollten Schutzhandschuhe tragen 2 3 4 SICHERHEISMASSNAHMEN Immer wenn Sie die Geh useabdeckung a
58. s may be reported by the system BIOS or the option ROMs The Response section in following table is divided in 3 different types Warning The message is displayed on screen and error is logged in SEL System will continue booting with degraded state User may want to replace erroneous unit Pause The message is displayed on screen and user input is required to continue User can take immediate corrective action or can choose to continue booting Halt System cannot boot unless error is resolved User needs to replace faulty part and restart the system Table 8 Post Error Messages and Handling Error Code Error Message Response 100 Timer Error Warning 103 CMOS Battery Low Warning 104 CMOS Settings Wrong Warning 105 CMOS Checksum Bad Warning 10B CMOS Memory Size different Warning 112 CMOS Time Not Set Warning 140 Refresh Timer Test Failed Halt 141 Display Memory Test Failed Warning 142 CMOS Display Type Wrong Pause 147 Unknown BIOS error Error code 147 this is really a Halt PMM MEM ALLOC ERH 148 Password Check Failed Halt 149 Unknown BIOS Error Error code 149 this is really Halt SEGMENT REG ERH 14A Unknown BIOS Error Error code 144A this is really Warning ADM MODULE ERH 14B Unknown BIOS Error Error code 14B this is really Warning LANGUAGE MODULE ERR 14D Primary Master Hard Disk Error Pause 14E Primary Slave Hard Disk Error Pause 14F Secondary Master Hard Disk Error Pause 150 Secondary Sl
59. stics pass but the connection fails Q Make sure the network cable is securely attached Q Make sure you specify the correct frame type in your NET CFG file The controller stopped working when an add in adapter was installed Q Make sure the cable is connected to the port from the onboard network controller LJ Make sure your BIOS is current See http support intel com support motherboards server SE7221BK1 E for a link to the current version L Make sure the other adapter supports shared interrupts Make sure your operating system supports shared interrupts Try reseating the add in adapter The add in adapter stopped working without apparent cause Try reseating the adapter first then try a different slot if necessary The network driver files may be corrupt or deleted Delete and then reinstall the drivers U U UU U L Run the diagnostics Troubleshooting Intel Entry Server Board SE7221BK1 E User Guide System Boots When Installing PCI Card System Server Management features require full time standby power This means some parts of the system have power going to them whenever the power cord is plugged in even if you have turned the system power off with the power button on the front panel If you install a PCI card with the AC power cord plugged in a signal may be sent to the command the system to boot Before installing a PCI card you should always U Turn off the server power by using the power button on the
60. to the operating system Please note that not all error conditions are supported by the BIOS beep codes Table 9 Beep Codes Number of Beeps Description Refresh failure Parity cannot be reset First 64 Kb memory failure Timer not operational Processor failure Reserved not used Exception interrupt error Display memory R W error Reserved not used CMOS Shutdown register test error Invalid BIOS such as POST module not found O ON OO c Bb Y N 8042 GateA20 cannot be toggled memory failure or not present 37 Intel Entry Server Board SE7221BK1 E User Guide Troubleshooting 38 An error or warning condition at boot can result in a series of beeps being issued known as beep codes These beeps have a code that identifies system or PCI card events For example some Intel RAID cards have beep codes Before checking for a system beep code error make sure the PCI card is not causing the beeping In the case of a Bootblock update where video is not available for text messages to be displayed speaker beeps are necessary to inform the user of errors For beep codes associated with a Bootblock update refer to the Intel Server Board SE7221BK1 E Technical Product Specification Regulatory and Compliance Information Intel Entry Server Board SE7221BK1 E User Guide Regulatory and Compliance Information Product Regulatory Compliance Product Safety Compliance The server board SE7221BK1 E complies with th
61. uipment and the receiver Connect the equipment to an outlet on a circuit other than the one to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Any changes or modifications not expressly approved by the grantee of this device could void the user s authority to operate the equipment The customer is responsible for ensuring compliance of the modified product Only peripherals computer input output devices terminals printers etc that comply with FCC Class A or B limits may be attached to this computer product Operation with noncompliant peripherals is likely to result in interference to radio and TV reception All cables used to connect to peripherals must be shielded and grounded Operation with cables connected to peripherals that are not shielded and grounded may result in interference to radio and TV reception Industry Canada ICES 003 Cet appareil num rique respecte les limites bruits radio lectriques applicables aux appareils num riques de Classe A prescrites dans la norme sur le mat riel brouilleur Apparelis Num riques NMB 003 dictee par le Ministre Canadian des Communications This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Europe CE Declaration of Con
62. ve CDROM or DVDROM drive operating system 11 Preface Intel Entry Server Board SE7221BK1 E User Guide For information about which accessories memory processors and third party hardware have been tested and can be used with your board and for ordering information for Intel products see http support intel com support motherboards server SE7221BK1 E Additional Information and Software If you need more information about this product or information about the accessories that can be used with this server board go to this link to find the information below http support intel com support motherboards server SE7221BK1 E In depth technical information about this product including the BIOS settings and chipset information in the Intel Entry Server Board SE7221BK1 E Technical Product Specification The latest product information Accessories or other Intel server products Hardware peripheral boards adapter cards and operating systems that have been tested with this product Chassis that have been tested with this product Processors that have been tested with this product DIMMs that have been tested with this product Power budget for this product Software to manage your Intel Server Diagnostics testing software Firmware and BIOS updates System drivers Intel Entry Server Board SE7221BK1 E User Guide Preface Safety Information A WARNING Before working with your server product w
63. vides support for two additional USB ports with front panel support four total possible USB 2 0 ports One external serial port and one serial header One 40 pin ATA 100 IDE connector An integrated Serial ATA controller with 4 serial ports output Support for Raid O 1 and 10 One standard 34 pin front panel connector supporting floppy drive interface with support for one drive for use with or without backplane PS 2 keyboard and mouse ports One Intel 82541PI Ethernet Controller Platform LAN Connect PLC device for 10 100 1000 Mbits second Ethernet LAN connectivity Intel Entry Server Board SE7221BK1 E LX and SR SKUs only Additional Intel 82547El Platform LAN Connect PLC device for 10 100 1000 Mbps Ethernet LAN connectivity Expansion Four independent PCI buses Capabilities One PCI 2 3 32 bit 33 MHz 5 V connector supporting full length PCI add in cards and one 82541PI Gigabit Ethernet Controller A second 32 bit 33 MHz 82541 PI Gigabit Ethernet Controller Intel Entry Server Board SE7221BK1 E LX and SR SKUs only Two PCI X 64 bit 3 3 volt slots which can support either Two full length PCI PCI X add in cards at 66 MHz or One PCI X 64 bit 100 MHz 3 3 V card One x8 PCI Express slot supporting x1 2 x4 or x8 8C5250E or One riser card supporting PCI PCI X or PCI Express add in card SR1425BK1 E Integrated Graphics Integrated graphics supporting SVGA Support for up to four system fan modules and one pr
64. y to roll back to the other BIOS in case of a failure with the new version The active partition from which the system boots shall be referred to as the primary partition The AMI FLASH update suite and Intel On line updates preserve the existing BIOS image on the primary partition The BIOS updates are diverted to the secondary partition After the update a Server Utilities Intel Entry Server Board SE7221BK1 E User Guide notification flag will be set During the subsequent boot following the BIOS update the system will continue to attempt to boot from the primary BIOS partition On determining that a BIOS update occurred in the previous boot the system will attempt to boot the new BIOS If a failure happens specialized hardware will switch back to the BIOS on the other partition thus affecting a Roll Back Recovering the BIOS In the rare event the system BIOS becomes corrupted and will not boot as a result use the following BIOS recovery method to return the system to normal operation gt NOTE BIOS recovery should only be used as last resort when the main system BIOS will not come up Manually Recovering the BIOS 1 Power down and uplug the system from the AC power source 2 Move the recovery jumper at JIF2 from pins 9 and 10 to cover pins 10 and 11 00 COQ cog Figure 15 BIOS Recovery Jumper 1 Insert a bootable disk containing the file AMIBOOT ROM USB disk on key CDRom or DVD or split the ROM file