Home

Panasonic CW-XC85HU Air Conditioner

image

Contents

1. Specifications are subject to change without notice for improvement Las especificacionas est n sujetas a cambios por majoras sin previo aviso AA 34 hd Panasonic Consumer Electronics Company Division of Panasonic Puerto Rico Inc Division of Panasonic Corporation of North Ave 65 de Infanteria Km 9 5 America San Gabriel Industrial Park One Panasonic Way Carolina Puerto Rico 00985 Secaucus New Jersey 07094 Panasonic Room Air Conditioner Limited Warranty Panasonic Consumer Electronics Company or Panasonic Sales Company collectively referred to as the Warrantor will repair this product with new or refurbished parts in case of defects in material or workmanship free of charge in the USA or Puerto Rico in accordance to the following All time periods start from the date of the original purchase ALL COMPONENTS 1 YEAR PARTS AND LABOR SEALED REFRIGERATING SYSTEM compressor and interconnecting tube 1 YEAR LABOR 5 YEARS PARTS FOR YEARS 2 THROUGH 5 SERVICE AND LABOR COSTS WILL BE THE RESPONSIBILITY OF THE CUSTOMER In home service in the USA can be obtained during the warranty period by contacting Panasonic toll free at 1 800 211 PANA 7262 to locate a PASC authorized Servicenter In home service in Puerto Rico can be obtained during the warranty period by calling the Panasonic Sales Company telephone number listed in the Servicenter Directory Note If the unit is installed at other th
2. 3 Ligeramente ensamble el soporte del alfeizar Soporte del Alf izar usando las partes de la fig 3 Tornillo O Tuerca 4 Fig 3 4 Seleccione la posici n que ubicar el soporte Tornillo Tipo A 6 del alf izar cerca del punto m s exterior del Guia Marco 9 a alf izar Ver Fig 4 ye po A 18 5 Pegue el soporte antepecho a los rieles de la caja en relacion a la posicion deseada usando dos tornillos Tipo A en cada soporte Ver Fig 4 Interior Exterior Fig 4 N 2 G ab Na T S H E x lt o j o lt Gabinete l l Tornillo Tipo B 6 El gabinete debe ser instalado con una peque a ca da cerca de 1 2 hacia abajo hacia afuera Ver Fig 5 Soporte del Alf izar Aproximamente 1 2 7 Adjunte el gabinete al banquete de la ventana atornillando los tornillos Tipo B Largo diecis is mil metros y menos a trav s del ngulo frontal en la banqueta de la ventana 8 Hale cada panel gu a completamente a cada lado de la ventana y repita del paso 2 Angulo de Delante Tornillo Tipo B f Soporte del Alf izar 2 Fig 5 9 Adjunte cada panel gu a a cada lado de la ventana usando tornillos Tipo Ver Fig 6 PRECAUCI N No perfore la charola del fondo La unidad est dise ada para operar con aproximadamente 1 2 de agua en la charola del fondo 10 Deslice el chasis dentro del gabinet
3. 2Hours gt 3Hours gt 4Hours gt 5Hours gt 6Hours gt 7Hours gt 8Hours gt 9Hours gt 10Hours gt 11Hours gt 12Hours gt O Model CW XC65HU MODE FAN SPEED Qr o 4 ECONOMY Panasonic FAN SPEED e Every time you push this button it is set as follows High F3 gt Low F1 gt Med F2 gt High F8 TEMPERATURE SETTING e This button can automatically control the temperature of the room The temperature can be set within a range of 60 F to 86 F by 2 F 16 C to 30 C by 1 C Select the lower number for lower temperature of the room ECONOMY e f the switch is set to On the fan stops when the compressor stops cooling Approximately every 3 minutes the fan will turn on and check the room air to determine if cooling is needed AIR SWING e This button can automatically control the air flow direction DRY e When this unit is in dry mode the fan rotates in low speed The fan stops when the compressor stops cooling Approximately every 3 minutes the fan will turn on and the unit checks the room air temperature to set itself Additional controls and important information Ventilation The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions When fresh air is necessary in the room set the ventilation y lever to the OPEN position The damper is opened and room air is drawn out EE Eoi NOTE Before using the ventil
4. Un cable de alimentaci n da ado debe sustituirse por uno nuevo proporcionado por fabricante del producto y no reparado Utilice el enchufe de la pared Consumo de Energ a Utilice un fusible de 15AMP o un Interruptor de 15AMP Standard 125V enchufe de 3 L neas de 15A 125V AC USO DE CORDONES DE EXTENSION Debido al potencial de peligro a su seguridad bajo ciertas circunstancias recomendamos encaredidamente no utiliar cordones de extensi n Sin embargo si usted decide usar un cord n de extensi n es absolutamente necesario que este sea un cord n listado bajo UL de tres espigas con conexi n a tierra calificado 15A 125V Todo el cableado deber realizarse de acuerdo con los c digos y reglamentos el ctricos locales NOTA El cableado dom stico de aluminio podr a ocasionar problemas especiales Consulte a un electricista calificado SEGURIDAD ELECTRICA NSTRUCCIONES DE CONEXION A TIERRA IMPORTANTES El aire acondicionado tiene una clavija de conexi n a tierra de tres patas en su cable de suminstro de energ a que dever enchufarse en un tomacorriente de pared de tres paras conectado a tierra adecuadamente para su protecci n contra un posible riesgo de electrocuci n Informacion Electrica IMPORTANTE FAVORLEA CON ATENCI N POR LA SEGURIDAD PERSONAL DEL USUARIO ESTE APARATO DEBE SER DEBIDAMENTE NEUTRALIZADO El cord n de energ a de ste aparato esta equipado con tres patas cable a tierra Utili
5. ARE LIMITED TO THE APPLICABLE WARRANTY PERIOD SET FORTH ABOVE Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above exclusions or limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state If a problem with this product develops during or after the warranty period you may contact your dealer or Servicenter If the problem is not handled to your satisfaction then write to the Consumer Affairs Department at the company address indicated above SERVICE CALLS WHICH DO NOT INVOLVE DEFECTIVE MATERIALS OR WORKMANSHIP AS DETERMINED BY THE WARRANTOR IN ITS SOLE DISCRETION ARE NOT COVERED COSTS AND SUCH SERVICE CALLS ARE THE RESPONSIBILITY OF THE PURCHASER For assistance please call 1 800 21 1 PANA 7262 or contact us via the web at http www panasonic com contactinfo Printed in China
6. GABINETE REJILLA FRONTAL RECOLECTOR DE AIRE FILTRO DE AIRE BANDEJA DE ENTRADA Modelo CW XC85HU SUSPENSORES VENTANILLAS VERTICALES COMPRESOR EVAPORADOR ES CONDENSADOR Ja PANEL DE CONTROL A BANDEJA CONTROL REMOTO eg EBLE DE CONEXI N EL CTRICA Modelo CW XC65HU SUSPENSORES COMPRESOR 21 CONDENSADOR EVAPORADOR SANTA PANEL DE CONTROL ES CONTROL REMOTO H CABLE DE CONEXI N EL CTRICA Instrucciones de Instalaci n Elija el major lugar Ti Para prevenir la vibracion y el ruido asegure de que la unidad este instaalada segura y firmemente Instale la unidad donde el sol no refleje directamente en la unidad La salida debe extenderse hacia afuera por lo menos 11 y no debe haber obstaculos como cercas o paredes en 20 de la parte de atr s del gabinete porque va ha prevenir la rediaci n de calor del condensador Restriciones del aire de afuera reducir grandemente la eficiencia del aire acondicion
7. filtro de aire 24 Caracteristicas Caracter sticas 25 Instrucciones de instalaci n Elija el major lugar 26 Requisitos de ventana 26 Contenido del juego de MSc o 27 Requisitos de las herra mientas sugeridas 27 Instalaci n del Gabinete 28 Datos Electricos 30 Informacion Electrica 31 Antes de avisar al Servicio T cnico Operacion normal Operacion anormal Oo PARA SU INFORMACION Escriba aqu los n meros de serie y modelo de las unidades exterior e interior N de Modelo N Serie Los n meros figuran en una etiqueta en el lateral de cada unidad Distribuidor Fecha de compra LEA ESTE MANUAL e Aqu encontrar numerosas sugerencias sobre c mo utilizar y mantener adecuadamente su acondicionador de aire Con unos cuantos cuidados preventivos se puede ahorrar mucho tiempo y dinero a lo largo de la vida til de su acondicionador de aire e En la tabla de sugerencias para la resoluci n de problemas encontrar respuestas a la mayor a de los problemas m s comunes Si consulta primero la tabla de Sugerencias para la resoluci n de problemas quiz ni siquiera necesite avisar al servicio t cnico PRECAUCION e Consulte con el servicio t cnico autorizado sobre la reparaci n o el mantenimiento de esta unidad e El acondicionador de aire no debe ser utilizado por ni os peque os o personas ine
8. manipule los No aplique aerosoles con No ponga una estufa etc interruptores con las manos insecticida o productos donde quede expuesta al mojadas inflamables flujo de aire directo e Esto podr a causar una sacudida Esto podr a causar un incendio o Esto podr a causar una el ctrica deformar la caja combusti n imperfecta Instructions de Fonctionnement Controles Modelo CW XC65HU Modelo CW XC85HU 4 ENECNDIDO APAGADO e Para ENCENDER el sistema presione el boton y para APAGARLO presione el boton otra vez e Este bot n tiene prioridad sobre todos los otros botones e Cuando Ud lo enciende por primera vez el sistema est en el y la temperatura es de 72 F 22 C 2 FR O VENTILADOR e Cada vez que presione este bot n las palabras COOL ECONOMY FAN y DRY aparecer n alternadamente 3 MARCADOR DE ENCENDIDO APAGADO e Cada vez que presione este bot n el marcador de tiempo se ajustar de la siguiente manera 1Hora gt 2 Horas gt 3 Horas gt 4 Horas gt 5 Horas gt 6 Horas gt 7 Horas gt 8 Horas gt 9 Horas gt 10 Horas gt 11 Horas gt 12 Horas gt Cancelar e La temperatura de ajuste se elevar 2 F 1 C 30 minutos despu s y otros 2 F 1 C media hora despu s VELOCIDAD DEL VENTILADOR e Cada vez que presione este bot n el ajuste es como sigue Alto F3 gt Bajo F1 gt Alto F2 gt Alto F3 6 AJUSTE DE LA TEMPERATURA e Este bot n puede controlar l
9. ESIVA 920mm x 30mm x 2mm TAPA DEL DESAGUE DESARMADOR REGLA CUCHILLO MARTILO LAPIZ NIVEL PREPARACION DEL CHASIS 1 Remueva los tornillos cuales sujetan el gabinete a ambos lados y en la parte de atr s 2 Deslice la unidad fuera del gabinete tomando el agarradero de la bandeja y hale hacia el frente mientras mantiene el gabinete 3 Corte el marco de la ventana con el largo apropiado Desprenda la parte de atr s y sujete el Banda adhensiva en la parte inferior del marco de la ventana 4 Inserte los paneles gu as en la guia superior 5 Sujete el armazon a la unidad con 4 tornillos Tipo A Tornillos para transporte Instalaci n del Gabinete EE 1 Abra la ventana Marque una linea en el centro del banqueta de la ventana o la ubicacion deseada del aire acondicionado Cuidadosamente ubique el gabinete en la N banqueta de la ventana y alinee la marca LZ aburete de la Ventana central en el frente inferior con el centro de la i elante Fig 1 l nea marcada en la banqueta de la ventana Ver Fig 1 2 Hale hacia abajo la parte inferior de la ventana hasta que se una detr s de la gu a superior Ver Fig 2 Banda adhesiva Gabinet Panel Guia NOTA e No hale la ventana hacia abajo tan apretadamente que el movimiento del panel gu a sea restringido Interior Exterior
10. N How to Install the Unit ee o 1 To prevent vibration and noise make sure the unit is installed securely and firmly 2 Install the unit where the sunlight does not Fence shine directly on the unit loa ly 3 The outside of the cabinet must extend Cooled air Heat outward for at least 28 cm 11 and there RE radiation should be no obstacles such as a fence or pa wall within 50 8 cm 20 from the back of yt E the cabinet because it will prevent heat radiation of the condenser Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner About 12 7 mm 1 2 Over 50 8 cm 20 76 2 cm 30 152 4 cm 60 CAUTION All side louvers of the cabinet must remain exposed to the outside of the structure 4 Install the unit a little slanted so the back is slightly lower than the front about 12 7 mm 1 2 This will force condensed water to flow to the outside 5 Install the unit with the bottom about 76 2 cm 30 152 4 cm 60 above the floor level Window Requirements NOTE All supporting parts should be secured to firm wood masonry or metal This unit is designed for installation in SETI CANS standard double hung windows with actual 91 44 cm 36 idths f 22 1 44 38 cm 15 min sud s from 55 88 cm 22 to 9 wit mt ivan Stool The top and bottom window sash must open sufficiently to allow a clear vertical opening of 38 cm 15 from the bottom of the upper
11. Panasonic Room Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Models CW XC65H U CW XC85HU p 7 E i Please read these operating instructions thoroughly before using your air conditioner and keep for future reference For U S customers For assistance please call 1 800 211 PANA 7262 or Register your product at http www panasonic com register CW382820391N Safety Precautions Safety Precautions 3 About the Controls on the Air Conditioner Cono Saa osas 5 Remote Controller 6 Ventilation auinen 7 Air Directi0N 7 How to Secure Drain Pipe 7 Care and Maintenance Air Filter Cleanino 8 Features RECAE ro eo ed 9 Installation How to Install the Unit 10 Window Requirements 10 Installation Kit Contents 11 Suggested Tool Requirements 11 Cabinet Installation 12 Electrical Data 14 Electrical Safety 15 Before you call for service Normal Operation Abnormal Operation O FOR YOUR RECORDS Staple your receipt to this page in case you need it later Write down the model and serial numbers here Model Serial You can find them on a label on the side of each unit Dealer s Name Date Purchased READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain
12. RA the figures to the right by considering the hole of the S DRAIN HOSE unit to fit drain pan to your own unit See Fig 3 d AEE 5 Slide the chassis back into the cabinet Reinstall the cabinet screws Secure the cabinet to chassis by using screws See Fig 4 SCREW Fig 3 O Care and Maintenance TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET Air Filter Cleaning i The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary TO REMOVE 1 Open the inlet grille upward by pulling out the bottom of the inlet grille or downward by pulling out the top of the inlet grille 2 Using the tab pull up slightly on the filter to release it and pull it down or up 3 Clean the filter with warm soapy water under 40 C 104 F 4 Rinse and gently shake the water from the filter and let it dry before replacing it CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance How to Insert Batteries y o o e Do not use rechargeable batteries Such batteries differ from standard dry cells in shape dimensions and performance e Remove the batteries from the remote controller if the air conditioner is not going to be used for an extended length of time e Keep the remote control away from infants and small children to prevent them from accidentally sw
13. a temperatura del cuarto autom ticamente La temperatura se puede ajustar de grado en grado desde 60 F hasta 86 F cada 1 F 16 C hasta 30 C cada 1 C Seleccione el numero mas bajo para la temperatura mas baja en el cuarto 6 AUTOGIRO Este bot n puede controlar autom ticament la direcci n del flujo de aire RECEPTOR DE SE AL Control remoto Precauci n El dispositivo de control remoto no funcionar adecuadamente si la ventana sensora del acondicionador de aire es expuesta a luz fuerte o si hay obst culos entre el dispositivo de control remoto y el acondicionador de aire Modelo CW XC85HU MODE FAN SPEED O A ECONOMY lt p Panasonic ENECNDIDO APAGADO e Para ENCENDER el sistema presione el bot n y para APAGARLO presione el bot n otra vez e Este bot n tiene prioridad sobre todos los otros botones e Cuando Ud lo enciende por primera vez el sistema est en el y la temperatura es de 72 F 22 C FRIO VENTILADOR e Cada vez que presione este boton las palabras COOL ECONOMY FAN y DRY aparecer n alternadamente MARCADOR DE ENCENDIDO APAGADO OPERACION DE PARADA e Cada vez que presione este bot n cuando el sistema est operando el marcador de tiempo se ajustar de la siguiente manera 1 Hora gt 2 Horas gt 3 Horas gt 4 Horas gt 5 Horas gt 6 Horas gt 7 Horas gt 8 Horas gt 9 Horas gt 10 Horas gt 11 Horas gt 12 Horas gt 0 e La tempera
14. acle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded PREFERRED METHOD Ensure proper ground exists before use Fig 12 DO NOT CUT OR REMOVE THE THIRD GROUND PRONG FROM THE POWER PLUG A SITUATIONS WHERE THE APPLIANCE WILL BE DISCONNECTED ONLY OCCASIONALLY TEMPORARY METHOD Metal screw Receptacle cover Because of potential safety hazards we strongly discourage the use of an adapter plug However if you wish to use an adapter a TEMPORARY CONNECTION may be made Use UL listed adapter available from most local hardware stores Fig 13 The large slot in the adapter must be aligned with the large slot in the receptacle to assure a proper polarity connection CAUTION Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated and the wall receptacle is grounded through the house wiring The customer should have the circuit checked by a qualified electrician to make sure the receptacle is properly grounded Disconnect the power cord from the adapter using one hand on each Otherwise the adapter ground terminal might break DO NOT USE the appliance with a broken adapter plug B SITUATIONS WHERE THE APPLIANCE WILL BE DISCONNECTED OFTEN Do not use an adapter plug in these situations Unplugging the power cord frequently can lead to an eventual breakage of the
15. ado CUIDADO Todas las ventanillas de los lados del gabinete deben mantenerse expuestas hacia afuera de la estructura m s baja que el frente cerca de 1 2 Radiacion de calor 5282 Aproximamente 1 2 Over 20 Instale la unidad un poco inclinada de tal forma que la parte trasera este ligeramente Esto forzara el agua del condensador hacia afuera Requistios de ventana Esta unidad esta disenada para que sea instalada en ventanas dobles estandares con una abertura actual de ancho desde 22 a 36 La parte superior e inferiro de la ventana debe abrir lo suficiente para permitir una abertura vertical libre de 15 desde la parte inferior de la ventana hasta la base de la misma 4 N 26 _ Xx y h y y m Instale la unidad con la parte inferior cerca de 30 60 arriba nivel de suelo 22 a 36 15 min Taburete Con cubierta de armazon NE Aif izar Exterior a Interior pared j 7 18 1 2 min Sin cubierta de armazon Contenido del Juego de Instalaci n Requisitos de las herra mientas sugeridas NO NOMBRE LA PARTE CANTIDAD PANEL GUIA SOPORTE DE ALFEIZAR TORNILLO TUERCA 1 2 3 4 5 7 TORNILLO TIPO A 10mm 25 64 6 TORNILLO TIPO B 25 1mm 3 16 16mm 5 8 5 32 16mm 5 8 TORNILLO TIPO C D4 tmm TIRA DE GOMA 5 32 16mm 5 8 CHAPA DE SOPORTE PARALA VENTANA BANDA ADH
16. allowing the batteries 1 Remove the cover from the back of the remote controller 2 Insert two AAA dry cell batteries e Be sure that the and directions are correct e Be sure that both batteries are new ELA gt ZA 3 Re attach the cover Features Learning parts name prior to installation will help you understand the installation procedure myers gt m VERTICAL AIR DEFLECTOR HORIZONTAL LOUVER en y ZEB Ew HORIZONTAL AIR DEFLECTOR o o 0 gt lt VERTICAL LOUVER alll Se a gt AIR DISCHARGE CABINET WA FRONT GRILLE lt AIR FILTER NN INLET GRILLE Model CW XC85HU BRACE VERTICAL LOUVER COMPRESSOR EVAPORATOR eae BASE PAN CONTROL BOARD REMOTE CONTROLLER POWER CORD Model CW XC65HU SZ EE Zz EN BRACE AK Z II AR AI IR COMPRESSOR EVAPORATOR ener BASE PAN CONTROL BOARD HA REMOTE CONTROLLER H POWER CORD INSTALLATIO
17. an normal window height and or has been custom installed e g through the wall the customer is responsible for removing the unit from its installation prior to the performance of in home service This warranty is extended only to the original purchaser A purchase receipt or other proof of date of the original purchase is required for service and parts replacement under this warranty This warranty only covers failures due to defects in materials and workmanship and does not cover normal wear or cosmetic damage The warranty does not cover damages which occur in shipment or failures which are caused by products not supplied by the warrantor or failures which result from accident misuse abuse neglect mishandling misapplication faulty installation maladjustment of customer controls improper maintenance alteration modification power line surge lightning damage improper voltage supply commercial use such as hotel office restaurant or other business or rental use of the product or service by anyone other than a PASC Factory Servicenter or a PASC authorized Servicenter or damage that is attributable to acts of God LIMITS AND EXCLUSIONS There are no express warranties except as listed above THE WARRANTOR SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OR ARISING OUT OF ANY BREACH OF THIS WARRANTY ALL EXPRESS AND IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY
18. ation feature and prior to installing the front grille pull down part until level with part 6 oS Direction IA The direction of air can be controlled wherever you want to cool by adjusting the horizontal louver and the vertical louver e VERTICAL AIR DIRECTION CONTROL HORIZONTAL AIR DIRECTION CONTROL Controlled Controlled by Remote manually Controller Model CW XC85HU Controlled manually The vertical air direction is adjusted by The horizontal air direction is adjusted by rotating rotating the horizontal louver forward or the vertical louver right or left manually or by backward manually Remote Controller How to Secure the Drain Pipe In humid weather excess water may cause the BASE PAN to overflow To drain the water remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of the BASE PAN Press the drain pipe into the hole by pushing down and away from the fins to avoid injury See Fig 1 Optional CW3H02502C 1 Remove the rubber plug and slide the chassis out Z from the cabinet See Fig 2 ade AA j 2 Install the drain pan over the corner of the cabinet ki S where you removed the plug with 4 or 2 screws See Fig 3 3 Connect the drain hose to the outlet located at the bottom of the drain pan You can purchase the drain Remove the i hose or tubing locally to satisfy your particular needs Drain hose is not supplied See Fig 3 4 Select the most appropriate connection from among
19. ce ste con un enchufe de pared de tres salidas a tierra Fig 12 para minimizar el peligro de choque el ctrico El cliente debe revisar el receptor de pared y el circuito por un electricista calificado para asegurarse que la recepci n esta debidamente neutralizada ASEG RESE QUE EXISTE DEBIDA NEUTRALIZACI N ANTES DE UTILIZAR EL APARATO Fig 12 M TODO PREFERIDO NO CORTE O REMUEVA LA TERCERA PATA GROUND DEL ENCHUFE A SITUACIONES EN LAS CUALES EL APARATO ES DESCONECTADO OCASIONALMENTE M TODO TEMPORAL Adaptador Tornillo de metal Cubierta del interruptor Fig 13 Debido al peligro potencial nosotros no recomendamos el uso de adaptadores Sin embargo si usted desea utilizar un adaptador una CONEXI N TEMPORAL puede ser efectuada Utilice adaptadores UL disponibles en la mayor a de los estable cimientos de herramientas Fig 13 La pata mas grande del adaptador debe ser alineada con la pata mas grande del interruptor para asegurarse una polarizaci n adecuada CUIDADO Adaptar la terminal del ground del adaptador a la cubierta de la pared con un tornillo no neutraliza el aparato a menos que la cubierta del tornillo sea de metal u no sea insolada y el receptor de pared este neutralizado a trav s del alambrado del la casa El cliente debe hacer verificar el circuito por un electricista calificado para asegurarse que el receptor esta debidamente neutralizado Desconecte el cord n de ene
20. d enciende el aire acondicionado debe debiera esperar un momento para que la habitaci n se enfrie E E aire frio se est e Aseg rese que todas las salidas de aire est n cerradas escapando para que el aire regrese e Coloque la ventana del aire acondicionado en la posici n m s cercana E El serpentin de refrigeraci n Establezca una temperatura m s alta A IAN El aire E E hielo bloquea el flujo de Ajustar el control de mode en Ventilaci n Alta o acondicionado aire y detiene el Erfriamiento Alto con la temperatura alta enfr a dernasiado enfriamiento del cuarto MEMO 33 PRODUCT SPECIFICATION SPECIFICATIONS ESPECIFICIONES DEL PRODUCTO Model CW XC65HU CW XC85HU Modelo COOLING CAPACITY 6 000 7 800 CAPACIDAD DE ENFRIAMIENTO ELECTRICAL RATING Phase Single Single CLASIFICION DE LA ELECTRICIDAD Fase Monofasico Monofasico Frequency 60 60 Frecuencia Voltage 115 Voltaja Current 6 6 Corriente Input Potencia EER 10 7 10 8 EER MOISTURE REMOVAL Pints h 1 8 2 3 DESHUMIDIFICACION Tinta h ROOM CIRCULATION Cf min 170 226 CIRCULACION DE AIRE pie min DIMENSIONS Height A inches 35 3 13 32 35 3 13 32 DIMENSIONES Alto pulgadas m Width m inches 46 9 18 32 46 9 18 15 32 Ancho m pulgadas m m lb b I Ib Depth inches 52 5 20 32 52 5 2021 32 Profundidad pulgadas NET WEIGHT b PESO NETO kb libras b libras GROSS WEIGHT kg PESO BRUTO kb
21. deterioration of quality etc Do not operate switches Do not apply an insecticide Do not put a heater etc with wet hands or flammable spray where it is exposed to direct air flow e It may cause an electric shock e t may cause a fire or deformation e It may cause imperfect of the cabinet combustion About the Controls on the Air Conditioner Controls Model CW XC85HU Model CW XC65HU TEMP OPERATION Y OPERATION e To turn the air conditioner ON push the OFF ON button To turn the air conditioner OFF push the button again e This button takes priority over any other buttons e When you first turn it on the air conditioner is on the High cool mode and the temperature is set at 72 F 22 C MODE e Every time you push this button it will toggle between COOL ECONOMY FAN and DRY 3 ON OFF TIMER e Every time you push the TIMER button timer is set as follows 1Hour gt 2Hours gt 3Hours gt 4Hours gt 5Hours gt 6Hours gt 7Hours gt 8Hours gt 9Hours gt 10Hours gt 11 Hours gt 12Hours gt O e The Setting Temperature will be raised by 2 F 1 C 30 min later and by 2 F 1 C after another 30 min FAN SPEED e Every time you push this button it is set as follows High F3 gt Low F1 gt Med F2 gt High F3 TEMP OPERATION TEMPERATURE SETTING e This button can automatically control the temperature of the room The temperature can be set within a range
22. e Ver Fig 7 CUIDADO Por razones de seguridad re _ lls an Conrdon i SSL 2 de Alimentacion instale los tornillos en los lados del S gabinete Tornillo Fig 7 11 Corte la tira de goma 8 a la medida apropiada e introd zcala entre la parte superior e inferior de la ventana Ver Fig 8 12 Sujete la chapade soporte en el marco de la ventana 9 con untornillo tipo C Chapa de soporte para Ver Fig 9 7 la ventana O 13 Pegue el panel frontal a la caja insertando los fijadores en el panel adentro los del panel de la caja Ver Fig 10 NOTA Se refiere por favor p 40 para poner juego de ventilaci n 14 Levante la parrilla de entrada y aj stela con tornillos Tipo A atrav s de la parrilla frontal Ver Fig 11 15 Ahora la instalaci n del aire acondicionado en la ventana es completada Vea los DATOS ELECTRICOS para instalar el cable de alimentaci n en la toma de corriente Datos Electricos q El cable de alimentaci n puede incluir un dispositivo interruptor de corriente La carcasa del enchufe cuenta con un bot n de prueba y otro de reinicio El dispositivo debe comprobarse peri dicamente presionando primero el bot n TEST y despu s RESET Si el bot n TEST no se desconecta o si el bot n RESET no permanece activo suspenda el uso del aire acondicionado y p ngase en contacto con un t cnico de servicio cualificado
23. e center mark on the bottom front with the center line marked in the window sill See Fig 1 Pull the bottom window sash down behind the upper guide until it meets See Fig 2 NO NOTE e Do not pull the window sash down so tightly that the movement of Frame Curtain is restricted 3 Loosely assemble the sill Support using the parts in Fig 3 4 Select the position that will place the sill support near the outer most point on sill See Fig 4 5 Attach the sill support to the cabinet track hole in relation to the selected position using 2 Type A screws in each support See Fig 4 6 The cabinet should be installed with a very slight tilt about 12 7 mm 2 downward toward the outside See Fig 5 Adjust the bolt and the nut of sill support for balancing the cabinet 7 Attach the cabinet to the window sill by driving the screws Type B through the front angle into window sill 00 Pull each Frame curtain fully to each window sash track and repeat step 2 Upper Guide SH Front Angle Window Sash an E Foam pe Cabinet Frame Curtain INDOOR OUTDOOR Sill Support E Nut Screw Type A Frame Guide Cabinet OUTDOOR Fig r N D gt O Q lt Sill support Fig 3 About 12 7 mm 1 2 Sash track 9 Attach each Frame curtain to t
24. engaged discontinue use of the air conditioner and contact a qualified service technician Damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacture and not repaired Use Wall Receptacle Power Supply Use 15 AMP time delay fuse or 15 AMP Standard 125V 3 wire grounding circuit breaker receptacle rated 15A 125V AC USE OF EXTENSION CORDS Because of potential safety hazards we strongly discourage the use of an extension cord However if you wish to use an extension cord use a CSA certified UL listed 3 wire grounding extension cord rated 15A 125V All wiring should be made in accordance with local electrical codes and regulations NOTE Aluminum house wiring may pose special problems Consult a qualified electrician ELECTRICAL SAFETY IMPORTANT GROUNDING INSTRUCTIONS Air conditioner has a three prong grounding plug on its power supply cord which must be plugged into properly grounded three prong wall receptacle for your protection against possible shock hazard y 1 4 L A y N Electrical Safety IMPORTANT PLEASE READ CAREFULLY FOR THE USER S PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord of this appliance is equipped with a three prong grounding plug Use this with a standard three slot grounding wall power outlet Fig 12 to minimize the hazard of electric shock The customer should have the wall recept
25. ent interrupter e Press the RESET button located on the power cord plug device is tripped elf the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician E Airflow is restricted e Make sure there are no curtains blinds or furniture blocking the front of the air conditioner E TEMP Control is setattoo Set the TEMP Control to a lower number high a number Air conditioner E The air filter is dirty e Clean the filter at least every 2 weeks does not cool as it See the operating instructions section eee E The room may have been When the air conditioner is first turned on hot you need to allow time for the room to cool down E Cold air is escaping e Check for open furnace floor registers and cold air returns e Set the air conditioner s vent to the closed position I Cooling coils have iced up See Air Conditioner Freezing Up below Air conditioner E ce blocks the air flow and Set the mode control at High Fan or High Cool with freezing up stops the air conditioner the high temperature from cooling the room MEMO Precauciones Importantes de Seguridad Precauciones Importantes de seguridad 19 Instrucciones de Funcionamiento COMO estaca 21 Control remoto 22 Menta COM a 23 Como controlar la direccion del aire 23 Como installar el Tubo de DesaQgU8 neoaea 23 Cuidado y Mantenimiento Limpieza de
26. ground terminal The wall power outlet should be replaced by a three slot grounding outlet instead USE OF EXTENSION CORDS Because of potential safety hazards we strongly discourage the use of an extension cord However if you wish to use an extension cord use a CSA certified UL listed 3 wire grounding extension cord rated 15A 125V A 15 UY Before you call for service Troubleshooting Tips Save time and money Review the chart below first and you may not need to call for service Normal Operating e You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high This design feature helps remove moisture and improve efficiency e You may hear the thermostat click when the compressor cycles on and off e Water will collect in the base pan during high humidity or on rainy days The water may overflow and drip from the outdoor side of the unit e The fan may run even when the compressor does not Abnormal Operation E 7he air conditioner is e Make sure the air conditioner plug is pushed unplugged completely into the outlet Air conditioner E The fuse is blown circuit e Check the house fuse circuit breaker box and does not start breaker is tripped replace the fuse or reset the breaker E Power failure e When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload E The curr
27. he window sash using screws 7 Type C See Fig 6 CAUTION DO NOT DRILL A HOLE IN THE BOTTOM PAN The unit is designed to operate with approximately 12 7 mm 2 of water in bottom pan 10 Slide the unit into the cabinet See Fig 7 CAUTION For security purposes reinstall screws at cabinet s sides 11 Cut the foam strip to the proper length and insert between the upper window sash and the lower window sash See Fig 8 12 Attach the window locking bracket with a type C screw See Fig 9 13 Attach the front grille to the cabinet by inserting the tabs on the grille into the tabs on the front of the cabinet Push the grille in until it Snaps into place See Fig 10 NOTE Please refer to p 7 for setting ventilation kit 14 Lift the inlet grille and secure it with two type A screws through the front grille See Fig 11 15 Window installation of room air conditioner is now completed See ELECTRICAL DATA for attaching power cord to electrical outlet _ Type cO Power cord Foam Strip Fig 8 Electrical Data Power cord may include a current interrupter device A test and reset button is provided on the plug case The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button If the TEST button does not trip or if the RESET button will not stay
28. l filtro ligeramente hacia arriba para sacarlo por abajo o arriba 3 Limpie el filtro con agua tibia y jabonosa bajo 40 C 104 F 4 Enjuague y sacuda el filtro suavemente bajo la corriente de agua y dejelo secar antes de reponerlo PRECAUCION NO OPERE el aire acondicionado sin filtro ya que la suciedad y el tamo obstruir el filtro y reducir la eficiencia del funcionamiento C mo poner las bater as 1 Quite la tapa de la parte posterior del telemando e No utilice bater s Para ello haga deslizar la tapa seg n la direcci n recargables stas son del la flecha diferentes de forma de dimensi n y uso respecto a las bater as secas usuales 2 Introduzca las dos AAA c lula seca bater as asegur ndose de que las direcciones y est n colocadas correctament Use bater as nuevas e Seque las bater as del telemando cuando el acondicionador no vaya a ser usado durante un largo per odo 3 Volver a cerrar resbalando la tapa hasta la posici n inicial e No deje el control remoto a mano de ninos y bebes para que no absorben las baterias 4 N N Caracter sticas Aprender el nombre de las partes antes de la instalaci n le ayudar a entender el proceso de instalaci n 0 Caracter sticas DEFLECTOR DE AIRE HORIZONTAL VENTANILLAS HORIZONTALES DEFLECTOR HORIZONTAL DE AIRE VENTANILLAS VERTICALES SALIDA DE AIRE Ly VDD
29. o follow the instructions N WARNING Do not operate or stop the unit by inserting or pulling out the power plug e t will cause electric shock or fire due to heat generation Do not operate with wet hands or in a damp environment e lt will cause electric shock Y AY VA Do not damage or use an unspecified power cord e It will cause electric shock or fire e f the power cord is damaged it must be replaced by the manufacturer or an authorized service center or a similarly qualified person in order to avoid a hazard Do not direct air flow at room occupants e This could lead to health problems y gt D e gt S le n Do not clean the air Ventilate well when used conditioner with water together with a stove etc When the air filter is to be removed do not touch the metal parts of the unit V S ped a gt Wy e It may cause an Injury e Water may enter the unit and An oxygen shortage may occur degrade the insulation lt may 3 S ay AN T cause an electric shock When the unit is to be Do not put a pet or house Do not use for special cleaned switch off and turn plant where it will be exposed purposes off the breaker to direct air flow e Since the fan rotates at high This could injure the pets or Re teas SU aaa speed during operation it may plants note planie and art objects i cause an injury It may cause
30. of 60 F to 86 F by 1 F 16 C to 30 C by 1 C Select a lower number for a lower temperature in the room AIR SWING e This button can automatically control the air flow direction REMOTE CONTROL SIGNAL RECEIVER Remote controller Precaution The Remote Controller will not function properly if strong light strikes the sensor window of the air conditioner or if there are obstacles between the Remote Controller and the air conditioner Model CW XC85HU MODE FAN SPEED O A ECONOMY gt Panasonic OPERATION e To turn the air conditioner ON push the button To turn the air conditioner OFF push the button again e This button takes priority over any other buttons e When you first turn it on the air conditioner is on the High cool mode and the temp at 72 F 22 C D MODE e Every time you push this button it will toggle between COOL ECONOMY FAN and DRY 3 ON OFF TIMER STOPPING OPERATION e Every time you push this button when the air conditioner is operating timer is set as follows 1 Hour gt 2Hours gt 3Hours gt 4Hours gt 5Hours gt 6Hours gt 7Hours gt 8Hours gt 9Hours gt 10Hours gt 11Hours gt 12Hours gt O e The Setting Temperature will be raised by 2 F 1 C 30 min later and by 2 F 1 C after another 30 min STARTING OPERATION e Every time you push this button when the air conditioner is not operating timer is set as follows 1 Hour gt
31. pon de plastico y deslice el chasis fuera See core del armario Ver Fig 2 2 Instale la bandeja de drenaje por encima de la a esquina de la tapa de donde retir el tap n con 4 o 2 tornillos Ver Fig 3 3 Conecte la manguera de drenaje a la salida situada en la parte inferior de la bandeja de drenaje Puede adquirir una manguera de drenaje o una tuber a Retire el tap n apropiada en su localidad que satisfaga sus dei necesidades particulares la manguera no se suministra Ver Fig 3 4 Seleccione la conexi n m s apropiada entre las NE E LA figuras siguientes teniendo en cuenta el orificio de la DE DRENAJE iid Eldameto g Fig 3 unidad para acoplar la bandeja de drenaje en su TORNILLOS unidad Ver Fig 3 5 Deslice el chasis en el interior del armario Vuelva a apretar los tornillos del armario Fije el armario al chasis con tornillos Ver Fig 4 as Cuidado y Mantenimiento APAGUE EL AIRE ACONDICIONADO Y SAQUE EL ENCHUFE DEL TOMA CORRIENTE DE LA PARED Limpieza de filtro de Aire il El filtro de aire detr s de la rejilla frontal debe ser revisado y limpiado por lo menos una vez por cada dos semanas o mas frecuentemente si es necesario La rejilla es disenado para limpiar el filtro tanto hacia arriba como hacia abajo PARA REMOVER 1 Abra la rejilla hacia arriba tirando la parte inferior de la rejilla o hacia abajo tirando la parte superior de la rejilla 2 Usando una lengueta tire e
32. rg a del adaptador utilizado una mano en cada uno De lo contrario la terminal del adaptador puede romperse NO UTILICE el aparato con un enchufe roto B SITUACIONES EN LAS CUALES EL APARATO ES DESCONECTADO CON FRECUENCIA No utilice un adaptador en estas circunstancias Desconectar el cord n de energ a con frecuencia lo llevar al eventual rompimiento de la terminal de neutralizaci n La saluda de energ a de la pared debe ser reemplazada por una salida de tres patas neutralizada USO DE EXTENSIONES Debido al peligro potencial no recomendamos la utilizaci n de extensiones Sin embargo si usted desea utilizar una extensi n utilice una certificada por CSA UL de tres alambres catalogada 15A 125V 31 Antes de avisar al Servicio T cnico Tips para solucionar problemas Ahorre temopo y dinero Cuando tenga alg n problema primero consulte el cuadro que se encuentra abajo y tal vez no necesite llamar para solicitar servicio t cnico Operaci n normal E e Durar te dias lluviosos o cuando la humedad es alta usted puede escuchar un ruido met llco causa do por agua recogida y arrojada contra el condensador Esta caracteristica ayuda a remover la humedad y mejorar la eficiencia e Usted puede escuchar que el termostato hace un click cuando se enciende o apaga el ciclo del comp esor e Durar te dias lluviosos o cuando la humedad es alta el agua ser recolectada on la base del aparato Esta agua podr fluir
33. sash to the window stool Offset 12 7 mm 2 to N 31 8 mm 11 4 Sil 4 Interior wall Exterior 47 cm 18 2 Without frame curtain M N f 1 y 0 y x y Installation Kit Contents NAME OF PARTS FRAME CURTAIN SILL SUPPORT BOLT NUT SCREW TYPE A 10mm 25 64 SCREW TYPE B D5 1mm 3 16 16mm 5 8 SCREW TYPE C D4 1mm 5 32 16mm 5 8 FOAM STRIP WINDOW LOCKING BRACKET FOAM PE 920mm x 30mm x 2mm DRAIN PIPE 4 lt NI amp NO PO DO PO k 0 O0 0O JNJ OD O1 A h O a a NOI CO Suggested Tool Requirements SCREWDRIVER RULER KNIFE HAMMER PENCIL LEVEL Shipping PREPARATION OF CHASSIS 1 Remove the screws which fasten the cabinet at both sides and at the back 2 Slide the unit from the cabinet by gripping the base pan handle and pulling while bracing the cabinet 3 Cut the window sash seal to the proper length Peel off the backing and attach the FOAM PE to the underside of the window sash 4 Insert the Frame Curtain into the upper guide 5 Fasten the curtains to the unit with 4 Type A screws ww Lower guide Cabinet Installation 1 Open the window Mark a line on center of the window sill or desired air conditioner location Carefully place the cabinet on the window sill and align th
34. stables sin supervisi n e Es preciso vigilar a los ni os peque os para asegurarse de que no juegan con el acondicionador de aire a 18 Precauciones Importantes de Seguridad Para prevenir tanto lesiones al usuario u otras personas como da os materiales es preciso seguir estas instrucciones E El manejo incorrecto debido a la inobservancia de estas instrucciones puede causar lesiones o da os cuya gravedad est clasificada en las siguientes indicaciones AN ADVERTENCIA Este s mbolo indica la posibilidad de lesiones mortales o graves AN PRECAUCION Este s mbolo indica la posibilidad de lesiones o da os materiales E El significado de los s mbolos utilizados en este manual se indica a continuaci n Conecte correctamente el enchufle e De otra forma ello ocasionaria una descarga el ctrica o incendio a causa de la generaci n de calor No modifique el largo del cable el ctrico y tampoco comparta el tomacorriente con otros aparatos e Ello ocasionaria una descarga el ctrica o incendio a causa de la generacion de calor Asegurese de no hacerlo Asegurese de seguir las instrucciones AN ADVERTENCIA No opere o pare la unidad insertando o tirando del enchufe e Ello ocasionar a una descarga el ctrica o incendio a causa de la generaci n de calor No lo maneje con las manos humedas e Puede ocasionar una descarga el ctrica No da e o utilize un cable el ctrico inadec
35. tura de ajuste se elevar 2 F 1 C 30 minutos despu s y otros 2 F 1 C media hora despu s l OPERACION DE INICIACION e Cada vez que presione este bot n cuando el sistema est operando el marcador de tiempo se ajustar de la siguiente manera 1Hora gt 2 Horas gt 3 Horas gt 4 Horas gt 5 Horas gt 6 Horas gt 7 Horas gt 8 Horas gt 9 Horas gt 10 Horas gt 11 Horas gt 12 Horas gt 0 Modelo CW XC65HU MODE FAN SPEED CO CS 44 ECONOMY Panasonic 4 VELOCIDAD DEL VENTILADOR e Cada vez que presione este bot n el ajuste es como sigue Alto F3 gt Bajo F1 gt Alto F2 gt Alto F3 AJUSTE DE LA TEMPERATURA e Este bot n puede controlar la temperatura del cuarto autom ticamente La temperatura se puede ajustar de grado en grado desde 60 F hasta 86 F cada 1 F 16 C hasta 30 C cada 1 C Seleccione el numero mas bajo para la temperatura mas baja en el cuarto AHORRADOR DE ENERG A El ventilador se detiene cuando el compressor no sigue enfriando e Aproximadamente cada 3 minutos el ventilador se encender y necesitar verificar la temperatura del cuarto para saber si es necesario m s enfriamiento AUTOGIRO Este bot n puede controlar autom ticament la direcci n del flujo de aire DRY Cuando esta unidad se torna al modo seco el ventilador gira en velocidad lenta El ventilador se detiene cuando el compresor se para de enfriar Apro
36. uado e Ello ocasionar a una descarga el ctrica o incendio No exponga durante mucho tiempo la piel al aire fr o procedente directamente del acondicionador e Esto podr a da ar su salud d 013839 ged Un 5 S amp A Cge N 9 Un e lt S Q cS 3 gt e O Ur B 5 D wie Uy Y lt 2 Q D Z Aa N PRECAUCION Cuando se vaya a quitar el No limpie el acondicionador Ventile bien cuando utilice el filtro de aire no toque las de aire con agua acondicionador junto con partes met licas de la unidad una estufa etc interior e Esto podria causar heridas e El agua podria entrar en la e En este caso tal vez se produzca unidad y degradar el aislamiento una falta de ox geno Tambi n podr a causar una sacudida el ctrica A ON aS NO ponga un animal dom stico No lo utilice para prop sitos ni una planta donde quede especiales directamente expuesto al flujo de aire Cuando limpie la unidad desconecte la alimentaci n y desconecte tambi n el disyuntor e Puesto que el ventilador gira a Esto podr a da ar al animal o a e No utilice este acondicionador de alta velocidad durante la la planta aire para conservar dispositivos operaci n podr a ocasionar de precisi n alimentos y objetos heridas de arte no ponga tampoco animales y plantas cerca de l Esto podr a deteriorar la calidad etc _ No
37. ximadamente cada 3 minutos se encendera el ventilador y la unidad comprueba la temperatura del aire de la habitacion para ajustarse a si mismo Controles adicionales e informacion importante Ventilaci n La palanca de ventilaci n debe estar en posici n CERRADA para poder mantener las mejores condiciones de enfriamiento Cuando se necesite aire fresco en la habitaci n y coloque la palanca de ventilaci n en posici n ABIERTA La Compuerta es abierta y el a aire de la habitacion es expulsado NOTA Antes de utilizar la caracter stica de ventilaci n haga un kit de ventilaci n Primero hale hacia abajo la parte A hasta que quede horizontal con la parte palanca vertical y la palanca horiziontal e CONTROL DE LA DIRECCI N VERTICAL DEL AIRE e CONTROL DE LA DIRECCI N HORIZONTAL DEL AIRE Controlado Controlado a dl por manual por manual Modelo CW XC85HU ll gt La direcci n vertical d ajustada rotando la palanca horizontal hacia adelanto o hacia atr s La direcci n horizontal del aire es ajustada rotando la palanca vertical hacia la derecha o hacia la izquierda manualmente o por Director Remoto Como Installar el Tubo de Desag e En climas h medos es posible que la BANDEJA EVAPORADORA se llene de agua Para quitar el agua acumulado es preciso conectar el tubo de desague Quite la TAPA DEL DESAGUE y conecte el TUBO a la BANDEJA EVAPORADORA Ver Fig 1 Opcional CW3H02502C 1 Retire el ta
38. y ser eliminada por el lado externo de la unidad e El ventilador podr correr a n cuando el compresor no est encendido Operaci n anormal E A E El aire acondicionado est Aseg rese que ei aire acondicionado est conectado desconectado completamente a la fuente de energia E El fusible est quemado el Cheque los fusibles interruptor de la casa y reemplace interruptor de energ a se ha los fusibles o reestablezca el interruptor de energ a Elaire Lo b I oqueado 0 AAA acondicionado no MM Falta de energ a e Cuando la energ a se reestablezca espere 3 minutos entiende para encender de nuevo el aire acondicionado Con esto evitar que se produzca una sobrecarga en el compresor E El dispositivo interruptor de e Presione el bot n RESET situado en el enchufe del cable corriente esta de alimentaci n desconectado e Si el bot n RESET no permanece activo suspenda el uso del aire acondicionado y p ngase en contacto con un t cnico de servicio cualificado ME flujo de aire esta e Aseg rese que no haya cortinas persianas o muebles restringido bloqueando el frente del aire acondicionado E Coloque el control de e Gire el control de TEMPERATURA a un n mero m s TEMPERATURA en un bajo n mero m s alto El aire E El filtro de aire est sucio e Limpie el filtro por lo menos cada dos semanas Vea la acondicionado no secci n de instrucciones de operaci n enfr a corno E El cuarto a n est caliente Cuando uste
39. your air conditioner properly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all CAUTION e Contact an authorized Service technician for repair or maintenance of this unit e The air conditioner is not intended for use by young children or infirm persons without supervision e Young children should be supervised to ensure that they do not play with the air conditioner a Safety Precautions To prevent injury to the user or other people and property damage the following instructions must be followed E Incorrect operation due to ignoring of instruction will cause harm or damage The seriousness is classified by the following indications AN WARNING This symbol indicates the possibility of death or serious injury AN CAUTION E Meanings of symbols used in this manual are as shown below Plug in the power plug properly e Otherwise it will cause electric shock or fire due to heat generation Do not modify power cord length or share the outlet with other appliances e t will cause electric shock or fire due to heat generation This symbol indicates the possibility of injury or damage to property only Be sure not to do this Be sure t

Download Pdf Manuals

image

Related Search

Related Contents

KeTop T20eco Benutzerhandbuch V1.01  TotalCode ERP User Manual  Chapitre 1 5 - E  Lassco Spinnit EBM-2.1 Paper Drill  DigitRadio 300  安全にお使いいただくために、取扱説明書の警告ー注意の項をよくお読み  Elections municipales et communautaires : mode d`emploi  CyberPower CPBC10400  取扱説明書を必ずご参照ください - フクダ エム・イー工業株式会社  Guía del usuario  

Copyright © All rights reserved.
Failed to retrieve file