Home

Frigidaire FAD052M7A Air Conditioner

image

Contents

1. L U 1 Sill support pp LY ML 2 Bottom mounting rail 8 Type A 4 9 Type B 9 10 Type C 8 11 Nut 2 12 Bolt 2 i Fig 8 Window Requirements These instructions are for a standard double hung window You will need to modify them for other types of windows The air conditioner can be installed without the accordion panels if needed to fit in a narrow window See the window opening dimensions below e All supporting parts must be secured to firm wood masonry or metal e The electrical outlet must be within reach of the power cord Storm Window Requirements 5000 and 6000 BTU models 14 min 22 to 30 With accordion panels 17 5 min Without accordion panels Fig 9 A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly To adjust for this attach a piece of wood to the stool WOOD PIECES WIDTH 2 LENGTH Long enough to fit inside the window frame Wood 1 2 higher than frame I KG Stool _ Storm window frame THICKNESS To determine the thickness place a piece of wood on the stool to make it 1 2 higher than the top of the storm window frame Attach securely with nails or screws provided by the installer Remove the Air
2. njaa Eg CLOSE VENT l i Fig 4 Vertical air flow adjustment manually To adjust vertical air flow direction adjust any one of the horizontal louver blades Fig 5 FRESH AIR VENTILATION This is usually kept in the closed position and use only when clearing smoke and or odors from the room When the ventilation switch is pushed to CLOSE the fresh air ventilation is closed when the ventilation switch is pushed to VENT the fresh air ventilation is opened Keeping the fresh air ventilation opened for along time will reduce the cooling effeciency ra oreo CLOS VENT Fig 6 CARE AND MAINTENANCE GINO HIN To avoid the possibility of personal injury be sure to disconnect power to the unit before servicing and or cleaning Pa Ww CHEMICALS J Do Not use gasoline benzene thinner Never attempt to clean the unit by A ige d or any other chemicals or any liquid pouring water directly over any of the insecticide on the air conditioner as surface areas as this will cause these substances may cause flaking deterioration of electrical components off of the paint cracking or deformation and wiring insulation of plastic parts CLEANING THE AIR FILTER If the air filter becomes clogged with dust air flow is obstructed and reduces cooling eff
3. 19 3 Insert the shutters into its frame bar 4 Clip the shutters onto the frame bars And install the upper and lower frame with the clips bars Upper Frame Bar Left Frame Bar Fig 20 Lower Frame Bar Install the Case in the Window A Open the window and mark the centerline of the window stool B Carefully place the case on the window stool and align the center mark on the bottom front with the centerline of the stool C Pull the window down behind the top mounting rail NOTE Do not shut the window so tightly that the movement of the accordion panels is restricted 13 Fig 21 D Loosely assemble the sill supports Indoor Outdoor Sill support Bolt Nut Fig 23 E Select the position that will place the sill supports near the outermost point on the sill Attach the sill supports to the case track hole in relation to the selected position using 4 type C screws in each supports Frame guide 1 3 Maximum Fig 24 F Adjust the bolt and the nut in each support so that the case is installed with a slight tilt to the outside Use a level about 1 3 will be the correct case slant to the outside G Secure the case to the window stool by using 6 type B screws Sill support H Pull the accordion panels to each window sash track Attach them on each side to the window sash and the window stool using 5 type B screws A Cut the foam top
4. turn the temperature knob to a higher number The air filter is dirty Clean the filter at least every 30 days See the Operating Instructions section The room may have been hot When the air conditioner is first turned on you need to allow time for the room to cool down Cold air is escaping Check for open furnace and cold air returns Set the air conditioners vent to the closed Cooling coils have iced up Ice blocks the air flow and stops the air conditioner from cooling the room Excessively hot and humid weather The air conditioner is not tilted to the outside Moisture is removed from indoor air and drains into rear of a cabinet where a fan blows it against the outdoor condenser coil e See Air conditioner freezing up below On models with control knobs set the mode control at HIGH FAN or HIGH COOL with the temp at 1 or 2 amp On models with touch pads set the controls at HIGH F3 FAN or HIGH F3 COOL and set the thermostat to a higher temperature This is normal For proper water disposal make sure the air conditioner slants slightly from the case front to the rear This is normal for a short period in areas with little humidity normal for a longer period in very humid areas m You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high This design feature helps remove moistur
5. conditioner From the Case 1 Removal of Air Filter A Press PUSH on the bottom corners of the inlet grill Pull the air filter down to remove 11 Fig 10 B Remove the 2 screws at the bottom and remove the frame from the cabinet Note No need to remove the selector and thermostat knobs C Remove the 2 screws on each side of the case Keep these for later use D Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case Foam Compressor CAUTION Be sure to remove the foam surrounding the compressor when installing If not it would harm the operation of the compressor See Fig 13 Prepare the Window and the Case A Cut the window sash seal to the proper length B Remove the backing from the Peel off the backing and attach the seal to the top mounting rail seal strip underside of the window sash and attach it to the bottom of the top mounting rail AN Fig 15 C Install the top mounting rail with 4 type A screws on the outside of the case Install the bottom rail inside of the case with 4 type C screws Insert the frames for the accordion panels into the top mounting rail and the frame guides 12 D Install the Accordion panels 1 Attach the two Connection Bar to 2 Connect the shutter with the Connection the case Bar Connection Bar ae Fig 18 a II Fig
6. Keep Well This Manual Read Rules for Safe Operation and Instructions Carefully WINDOW TYPE AIR CONDITIONER CONTENTS 1 ELECTRICAL SAFETY RULES LG 1 2 UNIT PARTS IDENTIFENMION kjemien 2 3 POINTS FOR ATTENTION WHEN OPERATING 3 4 OPERATION PANEL Cooling only type ccceccccceceseeeeeeeeseeeeeeeeeeeeeeaaes 4 PEFAIONNS RENN ee 4 5 CARE AND MAIN TENANOE seen es adaadadshaade 7 6 WINDOW INSTALLATION INSTRUCTIONS 10 7 TROUBLESHOOTING TIP scsececceanecenesccceceadcceedgaceedsceresecansestlcraneeiee 15 GN KO FIG z N All wiring must comply with local and national electrical codes and be installed by a qualified electrician If you have any questions regarding the following instructions contact a qualified electrician Never insert your fingers or any foreign objects into the air outlet Take special care to warn children of these dangers To avoid the possibility of personal injury be sure to disconnect power to the unit before installing and or servicing and or cleaning Ifthe supply cord is damaged it must be replaced by the manu facturer or its service agent or a similar qualified person in order to avoid a hazard 1 The power cord is distinguished according to the cord color 2 For your safety and protection this unit is grounded through the power cord plug when plugged into a matching wall outlet Please contact the manufacturer or i
7. circulation LOW COOL provides cooling automatically with minimum air circulation MED LOW COOL FAN LOW COOL OFF will completely shut off the unit When turning the SELECTOR knob from LOW COOL to HIGH COOL keep your speed as slow as possible Do not change the operation mode between LOW COOL and HIGH COOL too often THERMOSTAT THERMOSTAT The thermostat automatically starts and stops the running of the compressor in the air conditioner in order 5 4 to control and maintain a comfortable room temperature When the room temperature reaches the desired setting cooling will automatically stop When 3 9 the room temperature rises above cooling resumes This results in efficient use of power and economical cooling The operating method is as follows turn along the arrow the temperature setting becomes lower When you feel it is too cool rotate the knob to the original direction When you feel it is too hot rotate the knob to the COOLER direction gt During the cooling operation of the unit when the thermostat knob is rotated counterclockwise allow at least three minutes before turning back the knob to the COOLER direction Otherwise the fuse may blow due to an overload of the unit MANUAL LOUVER Horizontal air flow adjustment manually Move the T shaped handle left or right to adjust horizontal air flow C
8. e and improve efficiency m You may hear the thermostat click when the compressor cycles on and off m Water will collect in the base pan during high humidity or on rainy days The water may overflow and drip from the outdoor side of the unit m The fan may run even when the compressor does not 16 CS45 U 2200019260
9. iciency The air filter should be cleaned every two weeks 1 Removal of Air Filter 1 Press PUSH on the bottom corners of the inlet grill See Fig 7 2 Pull the air filter down to remove 2 Cleaning of Air Filter 1 Remove the dust clogged in the filter by tapping it or vacuum clean it 2 Wash the filter well with lukewarm water or a neutral cleaning agent 3 Attaching the Air Filter Installation of the air filter is the reverse of the removal process Never use hot water over 40 C 104 F to clean the air filter and air fresher Never attempt to operate the unit without the air filter FRONT PANEL Dust may accumulate on the front panel use soft wet cloth with a neutral cleaning agent to wipe it Never use water over 50 C alcohol gasoline acid solvent or brush to clean the front panel as this will damage the surface of the part End of Season Care See ag 1 Operating the fan alone for half a day See POINTS FOR ATTENTION to dry out the inside of the unit WHEN OPERATING on page 3 2 Turn off power and remove plug from wall outlet WINDOW INSTALLATION INSTRUCTIONS 6 Top mounting rail 5 Window sash seat seal strip 7 Foam top window gasket 4 Top mounting rail 3 Accordion panel lt 13 Connection bar
10. temp 18 43 C Indoor temp 21 32 C Cooling Operation IAE The relative humidity of room should be less than 80 If the unit is usedin a condition witha relative humidity over 80 there will be condensed water on the surface of the unit 5 If the unit is operated beyond the conditions specified above it may cause a failure of the unit 6 Relocation of the unit When changing the installation location of the air conditioner consult the selling agent from which you bought your unit OPERATION PANEL Cooling only type THERMOSTAT WAIT THREE MINUTES BEFORE RESTARTING co MED 9 COOL SELECTOR OFF HIGH HIGH COOL FAN LOW FAN LOW COOL Fig 2 OPERATION INSTRUCTION OPERATION PANEL N Fig 3 F Te 1 Pull the top of the operation cover to open it 2 Close the operation cover and press the top until it snaps into the locked position Note Dont press or swing the opened operation cover SELECTOR To set desired cooling temperature simply rotate the SELECTOR knob to the appropriate setting HIGH FAN will circulate the air at a maximum SELECTOR speed without cooling OFF MED FAN will circulate the air at a middle speed coo om without cooling HIGH FAN provides cooling automatically with maximum air circulation MED COOL provides cooling automatically with middle air
11. ts service agent or a similar qualified person if you want to replace it 3 Electrical requirement See the specifications 4 Be sure that the unit being correctly grounded The wall outlet should be provided with reliable earth wire 5 The unit should be provided with an individual branch circuit and the fuse size should be same as that of the power cord plug and wall outlet UNIT PARTS IDENTIFICATION 1 Front panel 2 Air filter 3 Frame 4 Cabinet 5 Air inlet grille outdoor side 6 Air outlet grille 7 Operation panel 8 Power supply and plug POINTS FOR ATTENTION WHEN OPERATING 1 During the course of operating if you have turned off the unit or changed operation mode from COOLING MODE to FAN MODE be sure to keep that state for at least three minutes before switching to COOLING MODE again THREE MINUTES 2 Attaching the Air Filter Before starting the air conditioner operation make sure that the air filter is well attached If the unit has not been used for a long time it is recommended to clean the air filter before your using the unit For continuous use clean the air filter at least once every two weeks 3 Before turning on the unit make sure that the air inlet grille and air outlet grille are not obstructed by anything 4 This air conditioner is designed to be operated under conditions as follows Outdoor
12. window gasket to the Va p window width B Stuff the foam between the glass and the window to prevent air and insects from getting into the room 14 Install the Air Conditioner in the Case The installation process is the reverse of the removal process on page 11 and 12 See Fig 11 Fig 28 TROUBLESHOOTING TIPS Save time and money Review the chart below first and you may not need to call for service Problem Possible Causes What To Do Air conditioner The air conditioner is Make sure the air conditioner plug is pushed does not start unplugged completely into the outlet The fuse is blown circuit Check the house fuse circuit breaker box and breaker is tripped replace the fuse or reset the breaker Power failure f power failure occurs turn the air conditioner OFF When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload 15 Problem Air conditioner does not cool as it should Air conditioner freezing up Water drips outside Water drips indoors Water collects in base pan Normal Operating Sounds Possible Causes Airflow is restricted What To Do Make sure there are no curtains blinds or furniture blocking the front of the air conditioner The temp control may not be set correctly On models with touch pads In COOL mode press the DECREASE Wpad amp On modes with control knobs

Download Pdf Manuals

image

Related Search

Related Contents

Télécharger  「わんにゃんらいふ 携帯型自動環境見守り計&超音波トレーナー」1月27  IP Addressing  Manual del propietario de freidoras eléctricas con control de lujo  Massive Led outdoor Pedestal/post 16706/47/10  Philips 2.1 Home theatre HTS3261  Manual Técnico  Husqvarna Edger Attachment User's Manual  Black & Decker CG700 Use & Care Manual  Manual de Instruções  