GE ZV950SDSS Kitchen Hood

image

Contents

1. air correctement Il ne faut pas vacuer l air dans l espace entre les parois d un mur un plafond ou un grenier un espace sanitaire ou un garage POWER SUPPLY IMPORTANT Please read carefully WARNING FOR PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED ADVERTISSEMENT POUR DES RAISONS DE S CURIT CET APPAREIL DOIT TRE CORRECTEMENT MIS LA TERRE Remove house fuse or open circuit breaker before beginning installation Do not use an extension cord or adapter plug with this appliance Follow National electrical codes or prevailing local codes and ordinances Electrical supply This vent hood must be supplied with 120V 60Hz and connected to an individual properly grounded branch circuit and protected by a 15 or 20 amp circuit breaker or time delay fuse e Wiring must be 2 wire with ground e If the electrical supply does not meet the above requirements call a licensed electrician before proceeding Preparation e Use metal ductwork These hoods must use 8 round duct It can transition to 3 1 4 x 12 reducing the maximum equivalent duct length to 75 feet e Install a wall cap with damper or roof cap at the exterior opening Order the wall or roof cap and any transition needed in advance Wall Framing for Adequate Support e This vent hood is heavy Adequate structural support must be provided The hood must be secured to vertical studs in the wall or to a horizontal support Se
2. The flexible metal duct should be straight and smooth and extended as much as possible Do NOT use flexible plastic ducting Note Any home ventilation system such as a ventilation hood may interrupt the proper flow of combustion air and exhaust required by fireplaces gas furnaces gas water heaters and other naturally vented systems To minimize the chance of interruption of such naturally vented systems follow the heating equipment manufacturer s guidelines and safety standards such as those published by NFPA and ASHRAE This Hood Must Use 8 Round Duct It Can Transition To 3 1 4 x 12 Duct Total Equivalent Quantity Equivalent Duct Piece Dimensions Length Used Length Round 1 ft straight per foot length 3 1 4 x 12 or 1 ft 3 1 4 x 24 per foot straight length 8 Round 90 elbow 15 ft 8 Round 45 elbow 3 1A x 12 90 elbow 3 1A x 12 or 45 elbow 3 1 4 x 12 90 flat elbow 8 round to 3 1 4 x 12 or 3 1 4 x 24 transition 3 1A x 12 to 8 round round transition 8 round to 3 1 4 x 12 or transition 90 elbow 16 ft 3 1A x 12 to 8 round round transition 90 elbow 17 ft 8 Round wall cap with damper 3 1A x 12 wall cap with damper 8 Round roof cap 8 Round roof vent CO WU APF OMBOS OE Actual length of straight duct plus duct fitting equivalent Equivalent length of duct pieces are based on
3. actual tests conducted by GE Evaluation Engineering and reflect requirements for good venting performance with any ventilation hood Total Duct Run Installation Preparation TOOLS AND MATERIALS REQUIRED NOT SUPPLIED e Tape measure e Pliers Knife e Safety glasses e Spirit level e Duct tape e Wire cutter stripper e Tape to mount template e Wire nuts e Gloves to protect against sharp edges e Electric drill with 1 8 and 3 8 bits e 120V 60Hz 15 or 20 Amp 2 wire with ground e Phillips and flat blade screwdrivers Properly grounded branch circuit e Hammer e Strain relief for junction cover e 8 round metal duct length to suit installation REMOVE THE PACKAGING The vent hood is shipped secured to a shipping board with a shipping bracket and 4 screws e Remove the duct cover parts box and other packaging e Lift the hood out of the box e Remove and properly discard the plastic wrapping Top Of Hood Junction Top Shipping Screws Remove Bottom Shipping Shipping Board Box Screws and Shipping Bracket e Locate and remove 2 screws at the top of the hood e Remove junction box cover Remove 2 screws at the bottom behind the filter e Install strain relief into junction box cover guides on the left and right sides Remove the ship ping bracket from behind the blower housing Discard the shipping bracket and board Installation Pre
4. thickness to the 6 1 4 dimension Wall Ducting If ductwork will vent to the rear e Use the level to draw a line straight up from the centerline on the template e Measure at least 8 above the top mounting bracket holes shown on the template to the centerline of an 8 1 2 dia duct hole Hole may be elongated for duct elbow HOUSE WIRING LOCATION e The junction box is located on the top of the hood at the back right side e Route house wiring as close to the ceiling location as possible through the ceiling soffit or back wall Wiring should enter at least 4 above the bracket on the right side Installation Instructions INSTALL FRAMING FOR HOOD SUPPORT IMPORTANT Framing must be capable of supporting 100 lbs View From Rear Cleats 1 x 6 Min rout Mounting pe Lor Centerline of Installation Space ao See If drywall is present mark the screw hole locations for the top mounting brackets Remove the template e Cutaway enough drywall to expose 2 vertical studs at the bracket location indicated on the template e Install a horizontal support at least 1 x 6 between two wall studs at the top bracket installation location The horizontal support must be flush with the room side of the studs Use cleats behind both sides of the support to secure the support to wall studs e Reinstall drywall 2 INSTALL MOUNTING BRACKET
5. Installation Instructions If you have questions call 800 GE CARES or visit our website at www monogram com gt 7950 36 Stainless Steel Vent Hood Monogram We bring good things to life Safety Information BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTAN T Save these instructions for local inspector s use IMPORTAN T Observe all governing codes and ordinances e Note to Installer Be sure to leave these instruc tions with the Consumer e Note to Consumer Keep these instructions with your Owner s Manual for future reference e Skill Level Installation of this appliance requires basic mechanical and electrical skills e Completion time 1 to 3 hours e Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Warranty For Monogram local service in your area 1 800 444 1845 For Monogram service in Canada call 1 888 880 3030 For Monogram Parts and Accessories call 1 800 626 2002 CAUTION Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION PRUDENCE A cause du poids et de la taille de ces hottes et pour r duire le risque de blessures et de dommages IL FAUT DEUX PERSONNES POUR FAIRE L INSTALLATION CORRECTEMENT WARNING To reduce
6. S This vent hood must be secured to the horizontal support or wall studs e With the template taped in place use a punch to mark all mounting screw locations e Drill 1 8 pilot holes at the 6 punched locations e Remove the template e The 4 support bracket holes must enter studs or the horizontal support Note Screws A and B are pre assembled onto the brackets Do not remove these screws e The two lower holes can be enlarged if they that did not enter studs to 3 8 Tap anchors for wall fasteners into the bottom holes Screws should be inserted by hand into the fasteners to allow anchors to expand against the wall material Remove the screws for final installation e Secure the mounting brackets to the wall studs with wood screws provided Installation Instructions 3 INSTALL DUCT BRACKET The duct bracket must be installed against the ceiling This bracket will hold the decorative duct cover in place at the top e Install the 2 small screws into the sides of the duct bracket Remove the screws Pre tapping the holes will insure ease of final installation Secure the bracket to the ceiling and wall e Mark the 4 screw hole locations e Drill 1 8 pilot holes in marked bracket location e If pilot holes do not enter studs enlarge the holes to 3 8 and install wall fastener anchors e Drive screws by hand into the fasteners to allow anchors to expand Remove the screws e
7. Secure the bracket to the ceiling and wall with wood screws and or fasteners 4 INSTALL THE HOOD Place the hood on the brackets and slide left to right to align with rectangular slots at the top e Adjust the installation height by tightening or loosen ing the screws A at the bottom of the brackets e Align the hood lower mounting holes with pilot holes in the wall e Using two large flat washers supplied install wood screws or wall fastener screws loosely into lower mounting holes Do not tighten Lower Mounting Holes Bracket Tabs Screws An e Level the hood by tightening or loosening the screws A located on the bottom mounting brackets e Tighten lower mounting screws e Tighten screws B located at the top of the mounting bracket against the hood to clamp the position Do not overtighten screws Installation Instructions 5 CONNECT DUCTWORK e Install ductwork making connections in direction of airflow as illustrated e Push duct over the exhaust outlet until it reaches the duct stops e Secure joints in ductwork with sheetmetal screws e Wrap all duct joints with duct tape for an airtight seal e Use duct tape to seal the flange connection CAUTI O N Do not use sheet metal screws at the hood flange connection Doing so will prevent proper damper operations Seal connection with tape only PRUDENCE Il ne faut pas utiliser de v
8. e page 8 e We strongly recommend that the vent hood with duct cover be on site before final framing and wall finishing This will also help to accurately locate the ductwork and electrical service e Route house wiring as close to the installation location as possible in the ceiling or soffit Wiring should enter at least 4 above the bracket on the right side e Connect the wiring to the house wiring in accordance with local codes Grounding instructions The grounding conductor must be connected to a ground metal permanent wiring system or an equip ment grounding terminal or lead on the hood WAR N l N G The improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded ADVERTISSEMENT Le mauvais branchement du fil de mise la terre peut causer un choc lectrique En cas de doute consulter un lectricien qualifi ou un technicien pour d terminer si Vappareil est la terre Installation Preparation DUCT FITTINGS Use this chart to compute maximum permissable lengths for duct runs to outdoors Note Do not exceed maximum permissable equivalent lengths Maximum duct length 100 foot for 8 round duct 75 foot for 3 1 4 x 12 duct Flexible ducting If flexible metal ducting is used all the equivalent feet values in the table should be doubled
9. is autoraurdeuses la connexion du collet de la hotte Ceci emp cherait le bon fonctionnement du registre N utiliser que du ruban adh sif pour assurer l tanch it du raccord 6 CONNECT ELECTRICAL WARN l NG If house wiring is not 2 wire with a ground wire a ground must be provided by the installer When house wiring is aluminum be sure to use U L approved anti oxidant compound and aluminum to copper connectors AVERTISSEMENT Si la maison n est pas cabl e avec deux fils et un fil de terre l installateur doit installer un fil de terre Quand les fils sont en aluminium il faut prendre soin d utiliser des connecteurs aluminium cuivre avec une pate antioxydante approuv e par UL INSTALL DUCT COVERS Mounting Screws e Place the decorative duct covers on top of the hood e Insert the lower portion of the duct cover into the impressions on the top of the hood Bottom 7 Notches Air Flow Duct Tape Over Seam and Screw _ Duct Tape Over Flange Duct Stops ooo ME eos Verify that power is turned off at the source e Insert house wiring through strain relief and tighten e Connect white leads to branch circuit white lead e Connect black leads to branch circuit black lead e Connect green yellow leads to branch circuit green lead or bare ground lead e Secure all connections with wire nu
10. oir vacuer lair correctement Il ne faut pas vacuer l air dans l espace entre les parois d un mur un plafond ou un grenier un espace sanitaire ou un garage Design Information CONTENTS Design Information Product Dimensions and Clearances Optional Accessories Advance Planning Ductwork Framing Power Supply Duct Fittings Installation Preparation Tools and Materials Required Remove the Packaging Check Installation Hardware Ductwork Wiring Locations Installation Instructions Step 1 Install Framing for Hood Support Step 2 Install Mounting Brackets Step 3 Install Duct Bracket Step 4 Install the Hood Step 5 Connect Ductwork Step 6 Connect Electrical Step 7 Install Duct Covers Step 8 Install Filters Step 9 Finalize Installation PRODUCT DIMENSIONS AND CLEARANCES po Pee Height to Ceiling 35 5 8 f The supplied duct cover fits 8 ft to 10 ft ceilings The vent hood must be installed 25 1 2 min and 30 max above the cooking surface Use the decorative duct cover to conceal ductwork running from the top of the hood to the ceiling The supplied 2 piece duct cover is sized to reach 8 ft to 10 ft ceiling heights The hood installation height from the cooking surface to the bottom of the hood depends upon ceiling height OPTIONAL ACCESSORIES ZX14SDSS optional stainless steel duct cover is available for ceiling heights greater than 10 f
11. paration CHECK INSTALLATION HARDWARE Locate the hardware accessory box packed with the hood and check contents 8 Wood ER 4 Wall Screws F Fasteners 2 Large Flat Washers 2 Phillips Head Decorative Screws Duct Cover Bracket 2 piece Decorative Duct Cover dimension shown for reference only Wall Mount Template DUCTWORK WIRING LOCATIONS Determine the exact location of the vent hood e Locate the template packed with the literature Measure 36 from the floor to the top of the cooking surface Add 25 1 2 or other recommended space from the cooking surface to the bottom of the hood Mark that location Use a level to draw a straight pencil line on the wall FOR CEILING 6 1 4 VENT DUCTING Centerline To Wall lt gt 8 1 2 Dia Hole Centerline i 8 Min Above Fa Top Mounting FOR WALL VENT DUCT Bracket Holes m T _ _ 1 i 1 i 1 l 1 J i 1 p aeu Eo EN y Tape the template in position along the penciled line CHECK TO BE SURE THE TEMPLATE IS LEVEL Ceiling ducting If ductwork will vent straight up to the ceiling e Use a level to draw a line straight up from the centerline on the template to the ceiling e Measure 6 1 4 from the back wall to the centerline of a 8 1 2 hole on the ceiling Note If drywall is not present add drywall
12. r la mise sous tension accidentelle S il n est pas possible de verrouiller le panneau du disjoncteur attacher un placard ou une tiquette tr s visible au panneau e For general ventilating use only Do not use to exhaust hazardous or explosive materials or vapors e Structural framing installation work and electrical wiring must be done by qualified person s In accordance with all applicable codes and stan dards including fire rated construction e Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those pub lished by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities e Local codes vary Installation electrical connections and grounding must comply with applicable codes In the absence of local codes the vent should be installed in accordance with National Electrical Code ANSI NFPA 70 1990 or latest edition CAUTI O N To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages PR U D E N C E faut prendre soin d installer un conduit vers l ext rieur pour r duire le risque d incendie et pouv
13. t and up to 14 ft Order the optional duct cover at the same time as the vent hood and have on site before installation Installation Height Depending on Ceiling Height Min A Cooking surface to bottom of hood should be e 25 1 2 max for 8 ft ceiling height e 25 1 2 to 30 for 9 ft ceiling height e 30 min for 10 ft ceiling height Plan the installation height carefully to avoid unsightly gaps above the hood Note Duct covers must be installed as shown in this book Do not build in the duct cover If service is required the duct cover must be removed to access hood components Installation ADVANCE PLANNING Ductwork Planning e Determine the exact location of the vent hood e Plan the route for venting exhaust to the outdoors e Use the shortest and straightest duct route possible For satisfactory performance duct run should not exceed 100 equivalent length for any duct configura tions e Refer to Duct Fittings chart to compute the maxi mum permissible length for duct runs to the outdoors CAUTI O N To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages PR U D E N CE faut prendre soin d installer un conduit vers l ext rieur pour r duire le risque d incendie et pouvoir vacuer l
14. the risk of fire or electrical shock do not use this range hood with any external solid state speed control device Any such alteration from original factory wiring could result in damage to the unit and or create an electrical safety hazard ADVERTISSEMENT Pour r duire le risque d incendie ou de choc lectrique il ne faut pas utiliser cette hotte avec un r gulateur de vitesse lectronique externe Toute modification de ce type du branchement d usine peut endommager l appareil ou cr er un risque de choc lectrique TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARN l NG TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer B Before servicing or cleaning unit switch power off at the service panel and lock service panel to prevent power from being switched on acciden tally If the service panel cannot be locked fasten a tag or prominent warning label to the panel ADVERTISSEMENT POUR REDUIRE LE RISQUE D INCENDIE DE CHOC ELECTRIQUE OU DE BLESSURES IL FAUT OBSERVER LES REGLES SUIVANTES A Utiliser cet appareil uniquement de la mani re pr vue par le fabricant En cas de question consulter le fabricant B Avant toute intervention ou nettoyage couper Valimentation lectrique au disjoncteur et verrouiller le panneau du disjoncteur pour vite
15. ts on each electrical connector e Push wires into junction box and replace cover Be sure wires are not pinched aS e Extend the inner duct upwards to the ceiling bracket e Secure the duct cover to the bracket with the 2 small Phillips screws provided 8 Installation Instructions INSTALL FILTERS e Remove protective film on the filters e Tip the filter into the slots at the rear of the opening Lift the filter and pull the knob forward until the filter rests on the slots 9 FINALIZE INSTALLATION e Remove the protective film covering the control panel on the front face of the hood and any other packaging materials e Refer to the Owner s Manual for operating instruc tions 11 e Install all 3 grease filters e To remove the filters grasp the knob push the filter towards the rear and tilt downwards Note While performing installations described in this book safety glasses or goggles should be worn For Monogram local service in your area call 1 800 444 1845 Note Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice Pub No 49 80095 Dwg No 164D4290P053 N D 124 7 01 Monogram hinted in tly General Electric Company Louisville KY 40225

Download Pdf Manuals

image

Related Search

Related Contents

Réparation automobile, services et contenu orienté détail l  AMD GA-K8N ULTRA-9 User's Manual  Visualizar/Abrir - Universidade Federal de Pernambuco  Oracle Enterprise Manager 1.0.4.0.0 User's Manual  Getting Started with matchIT  Caméra IP de vidéosurveillance  Aardvark I2C/SPI Host Adapter User Manual v5.15  Invacare® BirdieTM Invacare® BirdieTM Plus    Kyocera KC-120-1 User's Manual  